TECHNICAL MANUAL FOR AIR-COOLED CONDENSING UNITS MTE

Similar documents
Motor-driven condensing units MTE MTE R-410A

Galletti Water chillers and heat pumps catalogue

TECHNICAL MANUAL FOR CHILLERS AND HEAT PUMPS MPE

TECHNICAL MANUAL MCP. Multipurpose - total heat recovery reversible heat pumps. 7 kw - 41 kw

MPE 4-76 kw. Outdoor monobloc unit. Air chillers and heat pumps MPE PLUS. Efficiency under all operating conditions. 152 galletti.

TECHNICAL MANUAL FOR CHILLERS AND HEAT PUMPS MPE D

LER kw. Indoor motor-driven evaporating units. Motor-driven evaporating units LER PLUS

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

V-IPER. Installation, use and maintenance manual. Chillers and heat pumps 50 kw kw PLUS

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

MPI DC 8-29 kw. Outdoor monobloc unit with BLDC compressor. Air chillers and heat pumps MPI DC PLUS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

CHAPTER 6 CONDENSING UNITS

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

Water chillers water/water type SIGMA Technical information manual

HIWARM COMPACT kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

CRIMSON & CRIMSON MAX

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

Air Cooled Chillers & Heat Pumps WinPACK HE-A

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

BETA ECHOS. Air/water cooled chillers and heat pumps kw. General BETA ECHOS is a range of chillers and ductable air-water heat pumps.

LEP kw. Indoor monobloc water-water unit. Total heat recovery multi-purpose units LEP PLUS

NEMO A Split-system liquid chillers for indoor installation. Cooling Capacity: 5 26 kw

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

MCC 1 THE RANGE INDEX

LZA High efficiency air to water heat pumps with HP compressor

REMOTE CONTROL FOR CHILLER MYCHILLER

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw

nemo a hp rcgroupairconditioning R410A

HIWARM kw. Air-water system with external and internal BLDC unit. Total heat recovery multi-purpose units HIWARM PLUS

LZT High efficiency air to water heat pumps with E.V.I. compressors

WSK WSK. Water to water chillers and heat pumps VERSIONS ACCESSORIES

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

WZH Ground source heat pumps

RAUS air-cooled condensing units

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

Packaged air cooled liquid chillers for outdoor installation kw. technicalcatalogue T_EGL_1012_GB

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

ERAH MC Ka. Range kw. AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS FOR OUTDOOR INSTALLATION (Standard line)

Air-to-water scroll chillers

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:

TCHE-THHE TCEE

kw COOLING kw HEATING

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

Multi-pipe Units with Scroll Compressors. Model CMAA Cooling capacity kw Heating capacity kw

Blue Box Epsilon Echos +

LSN Series. Air cooled water chillers, heat pumps and motocondensing units with axial fans Capacities from 4 to 40 kw.

PRODUCT GUIDE

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

Компрессорно-конденсаторные агрегаты. Chiller. AQH DCI 20 to 30. Air Cooled Water Inverter Heat Pump Engineering Data Manual. 20 to 30 kw.

Conditioning your ambient, maximising your comfort.

Reversible Chillers and Heat Pumps - LEW SERIES kw

4,5 22,5 kw. technicalcatalogue. Air-conditioned server-racks for direct installation into the room T_CLSEVO_0113_GB

INSTALLATION, USE AND MAINTENANCE MANUAL MPE

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

RMA AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL


HYDROCIAT LW R407C. Water cooled chillers USE RANGE

WHA WHA. Ground source water to water heat pumps A ++ A ++ Versions

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

O L R E RGA ST RA N AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION TECHNICAL MANUAL

Air cooled water chillers

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

WZT High Efficiency Air to Water Split System Heat Pumps With E.V.I. Compressors

pyxis u pyxis ua NEW rcgroupairconditioning

Compact and silent Scroll compressors All-season operation

LZT High efficiency air to water heat pumps with E.V.I. compressors

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

Technical Data Ducted Three Phase Split System Air Conditioner

1

Aquaflair TRAC-TRAF-TRAH

WHA WHA. Ground source heat pumps OTHER VERSIONS ACCESSORIES

Transcription:

GB TECHNICAL MANUAL FOR AIR-COOLED CONDENSING UNITS MTE 5 kw - 213 kw

TABLE OF CONTENTS 1 The series...4 2 Constructive features...4 3 Layout of components...5 4 Models and configurations...13 5 Technical characteristics...14 6 Performance...15 6.1 MTE Cooling capacities...15 7 Sound level...19 8 Operating limits...20 8.1 Cooling mode...20 9 Electrical data and connections...21 10 Overall dimensions...23 11 Installation clearance requirements...31 12 Siting...34 12.1 Positioning of vibration dampers...34 13 Cooling circuit diagrams...35 TRANSLATION OF ORIGINAL INSTRUCTIONS WATER CHILLERS AND HEAT PUMPS ARE IN ACORDARCE WITH THE LAW 97/23/CE (PED) FILLING IN D1 FORM, APPROVED BY THE THIRD NOTIFIED BODY ICIM N 0425. The technical and dimensional data reported in this manual may be modified in view of any product improvement. 2 All copying, even partial, of this manual is strictly forbidden RG66005096 - Rev 02

UNIT IDENTIFICATION The unit data are reported on the rating label in this page. The label shows the following data: - Series and size of the unit - Date of manufacture - Main technical data - Manufacturer - The label is applied on the unit, usually on the enclosing panels beside the condenser coil. IMPORTANT: NEVER REMOVE THE LABEL - Serial number of the unit - The serial number permits to identify the technical characteristics and the components installed. - Without this datum it will be impossible to identify the unit correctly. Galletti S.p.A. via L.Romagnoli 12/a 40010 Bentivoglio (BO) Italia Serial number Code Date of production Cooling capacity (W) Heating capacity (W) Power supply Power input (kw) Weight (kg) Max power input (kw) Max running amperage (A) HP Power input (kw) Refrigerant Max refrigerant pressure (bar) Max refrigerant temperature ( C) Made in Italy CATEGORIA 1 - For any further information, contact the manufacturer: info@galletti.it - To get the weight of the unit, refer to the User Manual, Rated technical data table. RG66005096 - Rev 02 All copying, even partial, of this manual is strictly forbidden 3

1 THE SERIES MTE Air-cooled condensing units are designed for outdoor installation in both residential and industrial applications. The range uses R410A refrigerant, which assures high levels of performance with relatively low energy consumption and features 29 models in the chiller version, with cooling capacities ranging from 5 to 213 kw. 2 CONSTRUCTIVE FEATURES STRUCTURE Painted galvanised sheet steel structure (RAL9002) for an attractive look and effective resistance to corrosive agents. Fastening devices are made of non-oxidizable materials, or carbon steel that has undergone surface-passivating treatments. The compressor compartment is completely sealed and may be accessed on 3 sides thanks to easy-to-remove panels that greatly simplify maintenance and/or inspection. Sound insulation, available on request, can further reduce the noise emissions of the unit. ELECTRIC CONTROL BOARD The electric control board is constructed and wired in accordance with EEC Directive 73/23, Directive 89/336 on electromagnetic compatibility and related standards. Made of steel sheet, it is also protected by the enclosing panels of the machine. Electrical control panel with microprocessor controller accessible from the outside and low-voltage output for dry-contact thermostatic control of the unit, external disconnect switch, phase sequence control, compressor protection, compressor start-up time delay device. COOLING CIRCUIT - Scroll-type compressor (rotary up to 7 kw) housed in a compartment that can be sound insulated. - Finned block condenser with 8 mm copper piping and aluminium fins, characterised by ample heat exchange surfaces. - Dehydrating filter. - Flow indicator with humidity indicator. - Thermostatic valve as an optional. - High and low pressure switches. - Safety valve. - Schrader valves for checks and/or maintenance. - Refrigerant pressure gauges (optional). - Shut-off valves on the liquid and gas line; - Heating element on the compressor crankcase to prevent oil from being diluted during off cycles; - Nitrogen precharge under pressure; - Schrader valves for pressure-controlled charging operations; - Humidity and liquid flow indicator mounted so as to be visible from the outside with no need to remove the panels; FINNED BLOCK HEAT EXCHANGER Made of 8mm diameter copper pipes and aluminium fins, generously sized. The special engineering of the heat exchangers allows defrost cycles to be carried out at maximum speed in the models with heat pump operation, which brings clear benefits in terms of the integrated efficiency of the whole cycle. ELECTRONIC MICROPROCESSOR CONTROL The electronic control enables the complete control of the MTE unit. It can be easily accessed through a polycarbonate flap with IP65 protection rating. The self-adaptive logic enables the unit to operate even in systems where the water content is low, without the use of an inertial water storage reservoir. By reading the outdoor air temperature, it can automatically change the setpoint to adapt it to the outdoor load conditions or keep the unit running even in the harshest winter conditions. The basic controller comes complete with the MODBUS protocol and enables an immediate connection to ERGO networks. 4 All copying, even partial, of this manual is strictly forbidden RG66005096 - Rev 02

3 LAYOUT OF COMPONENTS MTE 05 09 MTE 05-09 LEGEND DESCRIPTION 1 R410A - air exchanger 2 Fan 3 Compressor 4 Refrigerant filter 5 Low pressure switch and charge inlet 6 High pressure switch and charge inlet 7 Inlet cock R410A 8 Outlet cock R410A RG66005096 - Rev 02 All copying, even partial, of this manual is strictly forbidden 5

3 LAYOUT OF COMPONENTS MTE 10 24 MTE 10-24 LEGEND DESCRIPTION 1 R410A - air exchanger 2 Fans 3 Compressor 4 Refrigerant filter 5 Low pressure switch and charge inlet 6 High pressure switch and charge inlet 7 Inlet cock R410A 8 Outlet cock R410A 6 All copying, even partial, of this manual is strictly forbidden RG66005096 - Rev 02

3 LAYOUT OF COMPONENTS MTE 29 38 MTE 29-38 LEGEND DESCRIPTION 1 R410A - air exchanger 2 Fans 3 Compressor 4 Refrigerant filter 5 Low pressure switch and charge inlet 6 High pressure switch and charge inlet 7 Inlet cock R410A 8 Outlet cock R410A RG66005096 - Rev 02 All copying, even partial, of this manual is strictly forbidden 7

3 LAYOUT OF COMPONENTS MTE 42 MTE 42 LEGEND DESCRIPTION 1 R410A - air exchanger 2 Fans 3 Compressor 4 Refrigerant filter 5 Low pressure switch and charge inlet 6 High pressure switch and charge inlet 7 Inlet cock R410A 8 Outlet cock R410A 8 All copying, even partial, of this manual is strictly forbidden RG66005096 - Rev 02

3 LAYOUT OF COMPONENTS MTE 53 82 MTE 53-82 LEGEND DESCRIPTION 1 R410A - air exchanger 2 Fan 3 Compressor 4 Refrigerant filter 5 Low pressure switch and charge inlet 6 High pressure switch and charge inlet 7 Inlet cock R410A 8 Outlet cock R410A 9 Liquid receiver RG66005096 - Rev 02 All copying, even partial, of this manual is strictly forbidden 9

3 LAYOUT OF COMPONENTS MTE 96 108 LEGEND DESCRIPTION 1 R410A - air exchanger 2 Fan 3 Compressor 4 Refrigerant filter 5 Low pressure switch and charge inlet 6 High pressure switch and charge inlet 7 Inlet cock R410A 8 Outlet cock R410A 9 Liquid receiver MTE 96-108 10 All copying, even partial, of this manual is strictly forbidden RG66005096 - Rev 02

3 LAYOUT OF COMPONENTS MTE 129 163 MTE 129-163 LEGEND DESCRIPTION 1 R410A - air exchanger 2 Fan 3 Compressor 4 Refrigerant filter 5 Low pressure switch and charge inlet 6 High pressure switch and charge inlet 7 Inlet cock R410A 8 Outlet cock R410A 9 Liquid receiver RG66005096 - Rev 02 All copying, even partial, of this manual is strictly forbidden 11

3 LAYOUT OF COMPONENTS MTE 169 214 LEGEND DESCRIPTION 1 R410A - air exchanger 2 Fan 3 Compressor 4 Refrigerant filter 5 Low pressure switch and charge inlet 6 High pressure switch and charge inlet 7 Inlet cock R410A 8 Outlet cock R410A 9 Liquid receiver MTE 169-214 12 All copying, even partial, of this manual is strictly forbidden RG66005096 - Rev 02

4 MODELS AND CONFIGURATIONS FIELD OF APPLICATION Air-cooled condensing units, cooling only, designed to be connected to evaporators operating with R410A The MTE units are designed for outdoor installation (protection rating IP24), in a position not accessible to the public. If protection grilles (accessory) are not provided or if the unit can be reached by unauthorized persons, special protection barriers should be provided in order to prevent access to the finned coil. Do not install the unit in places where inflammable gases or powders are present. MODELS AND VERSIONS The MTE series features 29 models in cooling only version. All models are pre-charged with nitrogen. N.B. The choice of some options may preclude the choice of others or make some other fields become mandatory. Contact Galletti S.p.A. for verification CODE BRAND NAME OF SERIES MTE Outdoor air-cooled condensing unit MODEL 005 007 Provides indications as to the cooling capacity of standard models 009 010 012 013 015 018 021 024 029 033 038 042 053 059 066 074 082 096 108 129 142 163 169 193 214 TYPES C Cooling mode only SUPPLY VOLTAGE 0 400V 3N 50 Hz M 230V single phase 50Hz CONFIGURATIONS / UNIT SETUPS 13 fields for customising unit as per customer specifications: FIELD CHARACT. DESCRIPTION 1 Expansion valve 0 Absent T Traditional A Electronic 230V 2 Liquid receiver 0 Absent 2 Present with cock 3 Liquid line accessories 0 Absent S Liquid line solenoid 4 Partial heat recovery (the condensation control must be added) 0 Absent 5 Air flow modulation 0 Absent C Condensation control with fans adjusted by potentiometer 6 Phase sequence relay 1 Present 7 Sound insulation 0 Absent 1 Compressor compartment soundproofing 2 Compressor silencing housings 3 Option 1 + option 2 8 Cooling accessories 0 None M Refrigerant pressure gauges 9 Remote control 0 Absent 2 Output RS485 (Modbus Carel protocol) S Simplified remote control M BASE microprocessor remote control (modbus disabling) 10 Special exchangers 0 Standard R Copper / Copper C Cataphoresis B Fins pre-coated with epoxy paint 11 Heat exchanger protective grille 0 Absent G Present 12 Compressor options 1 Crankcase heating element 2 Soft starter 13 Electronic controller 1 BASE Microprocessor Packing Wooden crate Wooden case Accessories Base rubber vibration dumpers Kit of spring vibration dampers RG66005096 - Rev 02 All copying, even partial, of this manual is strictly forbidden 13

5 Technical characteristics Technical data of MTE condensing units MTE-C 005 M 007 M 009 M 009 010 M 010 012 013 015 018 021 024 029 033 038 Power supply V-ph-Hz 230-1-50 230-1-50 230-1-50 400-3N-50 230-1-50 400-3N-50 400-3N-50 400-3N-50 400-3N-50 400-3N-50 400-3N-50 400-3N-50 400-3N-50 400-3N-50 400-3N-50 Cooling capacity kw 5,40 7,11 9,12 9,15 9,60 9,58 12,15 13,43 15,26 18,42 20,79 24,41 29,26 32,95 37,70 Total power input kw 1,72 2,30 3,34 3,15 3,36 3,36 4,42 4,43 5,48 6,65 7,50 8,42 9,88 11,45 12,27 EER 3,15 3,10 2,73 2,91 2,86 2,85 2,75 3,03 2,78 2,77 2,77 2,90 2,96 2,88 3,07 Maximum power input kw 2,4 3,1 4,1 4,1 4,5 4,6 5,9 5,9 6,9 8,6 9,3 10,7 14,0 15,9 17,4 Maximum current absorbed A 12,2 15,7 20 7,4 22,8 8,6 10,8 10,9 12,5 16,9 18 20,4 28,18 31,44 34,01 Startying ampere A 63 63 63 45 97 48 63 63 66 73 102 102 130 163 158 n of scroll compressors / circuits 1/1 1/1 1/1 1/1 1/1 1/1 1/1 1/1 1/1 1/1 1/1 1/1 1/1 1/1 1/1 Rated amount of refrigerant requested kg 1,5 2 2 2 2,3 2,3 2,3 3 3 3,8 3,8 4,1 3,6 4,0 5,5 High/low pressure switch bar 2/42 2/42 2/42 2/42 2/42 2/42 2/42 2/42 2/42 2/42 2/42 2/42 2/42 2/42 2/42 n of axial fans 1 1 1 1 2 2 2 2 2 2 2 2 4 4 4 Air flow m 3 /h 3.635 3.406 3.406 3.406 6.686 6.686 6.686 5.986 5.986 11.940 11.940 11.460 21.500 21.500 19.700 Gas line connection mm 16 16 16 16 22 22 22 22 22 28 28 28 32 32 32 Liquid line connection mm 10 10 10 10 12 12 12 12 12 16 16 16 16 16 16 Height mm 758 758 758 758 1.225 1.225 1.225 1.225 1.225 1.225 1.225 1.225 1.275 1.275 1.275 Lenght mm 960 960 960 960 1.220 1.220 1.220 1.220 1.220 1.220 1.220 1.220 1.565 1.565 1.565 Width mm 450 450 450 450 550 550 550 550 550 550 550 550 601 601 601 Sound Power level db(a) 67 67 67 67 69 69 69 70 70 77 77 77 80 80 80 Sound pressure level db(a) 39 39 39 39 41 41 41 42 42 49 49 49 52 52 52 Liquid Receiver (option) dm 3 1,3 1,3 1,3 1,3 4,2 4,2 4,2 4,2 4,2 4,2 4,2 4,2 7,8 7,8 7,8 Weights kg 72 85 94 94 165 165 168 170 170 175 190 204 230 239 259 MTE-C 042 053 059 066 074 082 096 108 129 142 163 169 193 214 Power supply V-ph-Hz 400-3N-50 400-3N-50 400-3N-50 400-3N-50 400-3N-50 400-3N-50 400-3N-50 400-3N-50 400-3N-50 400-3N-50 400-3N-50 400-3N-50 400-3N-50 400-3N-50 Cooling capacity kw 42,29 52,95 58,5 66 73,74 82,05 96,21 107,72 128,74 141,95 163,41 169,06 192,59 213,66 Total power input kw 13,45 16,21 18,22 21,27 23,64 27,77 32,93 38,42 40,95 45,95 57,86 55,88 66,2 78,47 EER 3,14 3,27 3,21 3,1 3,12 2,95 2,92 2,8 3,14 3,09 2,82 3,03 2,91 2,72 Maximum power input kw 19,2 24,4 26,3 30,1 33,2 37,9 43,4 49,8 54,9 60,1 74,5 75,6 85,4 100,6 Maximum current absorbed A 35,8 45,8 49,2 55,7 60,8 68,8 80,8 90,5 103,3 112,5 136,5 137,1 155,0 174,3 Startying ampere A 160 167 170 180 195 214 238 276 303 311 382 251 305 322 n of scroll compressors / circuits 1/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 4/2 4/2 4/2 Rated amount of refrigerant requested kg 7,0 10 10 12 10,3 13,8 13,8 18 20 22,8 29,5 32 30 32 High/low pressure switch bar 2/42 2/42 2/42 2/42 2/42 2/42 2/42 2/42 2/42 2/42 2/42 2/42 2/42 2/42 n of axial fans 2 4 4 4 4 4 6 6 8 8 8 6 6 6 Air flow m 3 /h 21.230 24.930 24.930 24.930 24.354 24.354 36.180 36.180 46.839 46.839 46.839 65.223 65.223 65.223 Gas line connection mm 35 35 35 35 35 35 42 42 42 42 42 54 54 54 Liquid line connection mm 16 22 22 22 22 22 28 28 28 28 28 28 28 28 Height mm 1.485 1.720 1.720 1.720 1.720 1.720 1.720 1.720 1.720 1.720 1.720 1.830 1.830 1.830 Lenght mm 1.990 2.010 2.010 2.010 2.010 2.010 2.360 2.360 3.190 3.190 3.190 3.540 3.540 3.540 Width mm 950 1.185 1.185 1.185 1.185 1.185 1.185 1.185 1.185 1.185 1.185 1.654 1.654 1.654 Sound Power level db(a) 82 76 76 76 77 80 82 82 82 82 83 83 84 84 Sound pressure level db(a) 54 48 48 48 49 52 54 54 54 54 55 55 56 56 Liquid Receiver (option) dm 3 10 10 10 10 10 10 8 8 12 12 12 12 12 12 Weights kg 360 525 530 540 570 650 730 730 1010 1055 1085 1330 1460 1470 - Cooling capacity: outdoor air temperature 35 C, evaporation temperature 3 C - Sound power measured according to standards ISO 3741 - ISO 3744 and EN 29614-1 - Sound pressure measured at a distance of 10 m and a height of 1.5 m above the ground in a clear field (fan side). - The maximum electrical input is the mains electricity that must be available in order for the unit to work. - The maximum current absorption refers to the current that will trigger the internal safety devices of the unit. It is the maximum current allowed in the unit. This value may never be exceeded; it must be used as a reference for determining the size of the power supply line and the related safety devices (refer to the wiring diagram supplied with the units). 14 All copying, even partial, of this manual is strictly forbidden RG66005096 - Rev 02

6 PERFORMANCE 6.1 MTE COOLING CAPACITIES Ta( C) Tev PF PA Outdoor air temperature Evaporation temperature Cooling capacity Total electrical input MTE MTE 005CM MTE 007CM MTE 009C0 MTE 009CM MTE 010C0 MTE 010CM MTE 012C0 Ta ( C) 15 20 25 30 35 40 45 Tev PF PA PF PA PF PA PF PA PF PA PF PA PF PA 0 5,69 1,23 5,48 1,33 5,23 1,43 4,96 1,54 4,66 1,66 4,33 1,79 3,96 1,92 2 6,02 1,22 5,80 1,33 5,54 1,44 5,26 1,56 4,94 1,68 4,59 1,82 4,22 1,96 3 6,20 1,22 5,97 1,33 5,70 1,44 5,41 1,56 5,09 1,69 4,73 1,83 4,35 1,98 4 6,38 1,21 6,14 1,32 5,87 1,44 5,57 1,57 5,24 1,70 4,88 1,84 4,49 1,99 5 6,56 1,21 6,32 1,32 6,04 1,45 5,73 1,58 5,40 1,71 5,03 1,86 4,63 2,01 6 6,75 1,20 6,50 1,32 6,22 1,45 5,90 1,58 5,56 1,72 5,18 1,87 4,78 2,03 8 7,15 1,19 6,88 1,32 6,58 1,45 6,25 1,59 5,89 1,74 5,50 1,90 5,08 2,06 10 7,56 1,18 7,28 1,32 6,96 1,46 6,62 1,61 6,24 1,76 5,84 1,93 5,41 2,10 0 7,64 1,68 7,28 1,79 6,91 1,92 6,53 2,06 6,14 2,22 5,73 2,39 5,32 2,59 2 8,12 1,68 7,74 1,80 7,34 1,93 6,93 2,08 6,51 2,25 6,07 2,43 5,63 2,64 3 8,37 1,68 7,97 1,80 7,56 1,94 7,14 2,09 6,70 2,27 6,26 2,45 5,80 2,66 4 8,63 1,67 8,21 1,80 7,79 1,94 7,35 2,10 6,90 2,28 6,44 2,47 5,97 2,69 5 8,89 1,67 8,46 1,80 8,02 1,95 7,57 2,11 7,11 2,30 6,64 2,50 6,15 2,71 6 9,16 1,67 8,72 1,80 8,26 1,96 7,80 2,13 7,32 2,31 6,84 2,52 6,34 2,74 8 9,72 1,66 9,25 1,81 8,77 1,97 8,27 2,15 7,77 2,34 7,25 2,56 6,73 2,79 10 10,30 1,65 9,80 1,81 9,29 1,98 8,77 2,17 8,24 2,38 7,70 2,60 7,14 2,84 0 10,28 1,92 9,71 2,14 9,12 2,40 8,51 2,70 7,87 3,04 7,21 3,42 6,52 3,84 2 10,96 1,94 10,35 2,17 9,72 2,43 9,07 2,74 8,39 3,08 7,68 3,47 6,96 3,90 3 11,31 1,95 10,68 2,18 10,03 2,45 9,35 2,76 8,65 3,11 7,93 3,50 7,18 3,93 4 11,66 1,96 11,01 2,20 10,34 2,47 9,64 2,78 8,92 3,13 8,17 3,53 7,40 3,96 5 12,02 1,97 11,35 2,21 10,66 2,49 9,94 2,80 9,19 3,16 8,42 3,56 7,63 3,99 6 12,38 1,99 11,69 2,23 10,98 2,51 10,24 2,83 9,47 3,19 8,68 3,59 7,86 4,02 8 13,13 2,02 12,39 2,27 11,63 2,56 10,84 2,88 10,03 3,25 9,19 3,65 8,33 4,09 10 13,89 2,05 13,11 2,31 12,30 2,61 11,46 2,94 10,60 3,31 9,71 3,72 8,80 4,16 0 10,12 2,13 9,59 2,33 9,03 2,59 8,44 2,90 7,83 3,26 7,18 3,68 6,51 4,16 2 10,80 2,15 10,23 2,36 9,63 2,62 9,00 2,94 8,34 3,31 7,65 3,74 6,93 4,22 3 11,15 2,16 10,56 2,37 9,94 2,64 9,29 2,96 8,60 3,34 7,89 3,77 7,15 4,26 4 11,51 2,17 10,90 2,39 10,25 2,66 9,58 2,98 8,87 3,37 8,13 3,80 7,36 4,29 5 11,88 2,18 11,24 2,40 10,57 2,68 9,87 3,01 9,14 3,39 8,38 3,83 7,58 4,33 6 12,25 2,20 11,59 2,42 10,89 2,70 10,17 3,03 9,41 3,42 8,62 3,87 7,80 4,37 8 13,00 2,22 12,29 2,45 11,55 2,74 10,78 3,08 9,97 3,48 9,13 3,94 8,26 4,45 10 13,78 2,25 13,02 2,49 12,22 2,79 11,40 3,14 10,54 3,55 9,64 4,01 8,72 4,53 0 10,71 2,34 9,95 2,51 9,24 2,73 8,59 2,99 7,97 3,30 7,41 3,66 6,89 4,06 2 11,50 2,35 10,70 2,52 9,94 2,74 9,24 3,01 8,58 3,32 7,97 3,69 7,41 4,09 3 11,91 2,35 11,09 2,52 10,31 2,75 9,58 3,02 8,90 3,34 8,27 3,70 7,68 4,11 4 12,34 2,35 11,49 2,53 10,69 2,75 9,94 3,03 9,23 3,35 8,57 3,72 7,96 4,13 5 12,78 2,35 11,91 2,53 11,08 2,76 10,30 3,04 9,57 3,36 8,89 3,73 8,25 4,15 6 13,23 2,35 12,33 2,54 11,48 2,77 10,68 3,05 9,92 3,38 9,22 3,75 8,55 4,17 8 14,18 2,35 13,23 2,54 12,33 2,78 11,47 3,07 10,66 3,40 9,90 3,78 9,18 4,21 10 15,19 2,35 14,18 2,55 13,22 2,80 12,31 3,09 11,44 3,43 10,62 3,82 9,85 4,25 0 10,72 2,34 9,96 2,51 9,25 2,73 8,59 2,99 7,98 3,30 7,42 3,66 6,90 4,06 2 11,51 2,35 10,71 2,52 9,95 2,74 9,25 3,01 8,59 3,32 7,98 3,69 7,42 4,09 3 11,92 2,35 11,10 2,52 10,32 2,75 9,59 3,02 8,91 3,34 8,28 3,70 7,69 4,11 4 12,35 2,35 11,50 2,53 10,70 2,75 9,95 3,03 9,24 3,35 8,58 3,72 7,97 4,13 5 12,79 2,35 11,92 2,53 11,09 2,76 10,31 3,04 9,58 3,36 8,90 3,73 8,26 4,15 6 13,25 2,35 12,35 2,54 11,50 2,77 10,69 3,05 9,93 3,38 9,22 3,75 8,56 4,17 8 14,20 2,35 13,25 2,54 12,34 2,78 11,48 3,07 10,67 3,40 9,91 3,78 9,19 4,21 10 15,21 2,35 14,20 2,55 13,24 2,80 12,32 3,09 11,45 3,43 10,63 3,82 9,86 4,25 0 13,83 2,84 12,83 3,10 11,90 3,42 11,02 3,80 10,20 4,24 9,44 4,74 8,73 5,31 2 14,80 2,87 13,74 3,14 12,74 3,47 11,81 3,86 10,94 4,31 10,13 4,82 9,38 5,39 3 15,30 2,89 14,21 3,17 13,19 3,50 12,23 3,89 11,33 4,34 10,49 4,86 9,72 5,43 4 15,82 2,91 14,70 3,19 13,65 3,53 12,65 3,92 11,73 4,38 10,87 4,90 10,08 5,47 5 16,36 2,94 15,20 3,22 14,12 3,56 13,10 3,96 12,15 4,42 11,26 4,94 10,44 5,52 6 16,91 2,96 15,72 3,24 14,60 3,59 13,55 3,99 12,57 4,46 11,66 4,98 10,82 5,56 8 18,06 3,00 16,80 3,30 15,62 3,65 14,51 4,07 13,47 4,54 12,50 5,07 11,61 5,66 10 19,27 3,05 17,94 3,36 16,69 3,72 15,52 4,14 14,42 4,63 13,40 5,17 12,46 5,76 RG66005096 - Rev 02 All copying, even partial, of this manual is strictly forbidden 15

6 PERFORMANCE 6.1 MTE COOLING CAPACITIES Ta( C) Tev PF PA Outdoor air temperature Evaporation temperature Cooling capacity Total electrical input MTE MTE 013C0 MTE 015C0 MTE 018C0 MTE 021C0 MTE 024C0 MTE 029C0 MTE 033C0 Ta ( C) 15 20 25 30 35 40 45 Tev PF PA PF PA PF PA PF PA PF PA PF PA PF PA 0 15,47 2,96 14,33 3,20 13,26 3,50 12,27 3,86 11,34 4,29 10,49 4,78 9,70 5,33 2 16,46 2,98 15,27 3,23 14,16 3,54 13,11 3,91 12,14 4,34 11,23 4,84 10,40 5,39 3 16,98 3,00 15,77 3,25 14,63 3,56 13,55 3,93 12,55 4,37 11,62 4,87 10,76 5,43 4 17,52 3,01 16,28 3,26 15,11 3,58 14,01 3,96 12,98 4,40 12,03 4,90 11,14 5,47 5 18,07 3,02 16,80 3,28 15,61 3,60 14,48 3,98 13,43 4,43 12,44 4,94 11,53 5,51 6 18,64 3,04 17,34 3,30 16,12 3,62 14,97 4,01 13,88 4,46 12,87 4,97 11,93 5,55 8 19,82 3,07 18,47 3,34 17,19 3,67 15,98 4,07 14,84 4,53 13,77 5,05 12,78 5,63 10 21,07 3,10 19,66 3,38 18,32 3,72 17,05 4,13 15,85 4,60 14,73 5,13 13,67 5,72 0 17,89 3,52 16,52 3,83 15,24 4,22 14,05 4,69 12,94 5,25 11,93 5,89 11,00 6,60 2 19,02 3,56 17,59 3,88 16,25 4,28 14,99 4,76 13,83 5,33 12,75 5,97 11,77 6,70 3 19,61 3,58 18,15 3,91 16,77 4,31 15,49 4,80 14,29 5,37 13,19 6,02 12,17 6,75 4 20,22 3,60 18,72 3,93 17,32 4,34 16,00 4,84 14,77 5,41 13,63 6,07 12,59 6,81 5 20,84 3,63 19,31 3,96 17,87 4,38 16,53 4,88 15,27 5,46 14,10 6,12 13,01 6,86 6 21,48 3,65 19,92 3,99 18,45 4,41 17,07 4,92 15,77 5,50 14,57 6,17 13,46 6,92 8 22,81 3,70 21,18 4,05 19,64 4,49 18,19 5,00 16,83 5,60 15,56 6,28 14,38 7,05 10 24,21 3,75 22,51 4,12 20,90 4,57 19,38 5,10 17,95 5,71 16,61 6,41 15,36 7,18 0 21,59 4,48 19,94 4,83 18,39 5,27 16,95 5,80 15,61 6,43 14,39 7,15 13,27 7,96 2 22,95 4,52 21,22 4,88 19,60 5,34 18,09 5,88 16,69 6,52 15,39 7,25 14,20 8,07 3 23,66 4,55 21,90 4,91 20,24 5,37 18,69 5,92 17,25 6,56 15,91 7,30 14,69 8,13 4 24,39 4,57 22,59 4,94 20,89 5,41 19,31 5,96 17,82 6,61 16,45 7,36 15,19 8,19 5 25,14 4,60 23,30 4,97 21,57 5,44 19,94 6,01 18,42 6,66 17,01 7,41 15,70 8,26 6 25,91 4,62 24,03 5,01 22,26 5,48 20,59 6,05 19,03 6,72 17,58 7,47 16,24 8,32 8 27,52 4,68 25,56 5,08 23,70 5,57 21,95 6,15 20,31 6,83 18,78 7,60 17,35 8,46 10 29,21 4,74 27,16 5,15 25,22 5,66 23,39 6,26 21,66 6,95 20,04 7,74 18,54 8,62 0 22,44 5,12 21,21 5,52 20,05 6,00 18,96 6,57 17,94 7,21 16,99 7,94 16,11 8,76 2 23,83 5,10 22,53 5,53 21,30 6,05 20,14 6,64 19,04 7,32 18,02 8,08 17,06 8,92 3 24,56 5,11 23,22 5,55 21,95 6,08 20,74 6,69 19,61 7,38 18,55 8,15 17,55 9,00 4 25,30 5,12 23,92 5,57 22,61 6,11 21,37 6,73 20,19 7,44 19,09 8,22 18,05 9,09 5 26,07 5,13 24,64 5,60 23,29 6,15 22,00 6,79 20,79 7,50 19,64 8,30 18,56 9,18 6 26,85 5,16 25,38 5,64 23,98 6,20 22,66 6,84 21,40 7,57 20,21 8,38 19,09 9,27 8 28,46 5,22 26,91 5,72 25,42 6,30 24,00 6,96 22,65 7,71 21,37 8,54 20,16 9,45 10 30,14 5,31 28,49 5,82 26,91 6,42 25,40 7,10 23,96 7,86 22,58 8,70 21,28 9,63 0 26,34 5,71 24,90 6,17 23,54 6,72 22,27 7,36 21,07 8,10 19,95 8,93 18,92 9,85 2 27,98 5,69 26,45 6,18 25,01 6,77 23,64 7,45 22,36 8,22 21,15 9,08 20,03 10,04 3 28,83 5,70 27,26 6,20 25,77 6,80 24,36 7,50 23,03 8,28 21,78 9,16 20,61 10,13 4 29,71 5,71 28,09 6,23 26,55 6,84 25,09 7,55 23,71 8,35 22,41 9,25 21,20 10,23 5 30,60 5,73 28,93 6,26 27,35 6,89 25,84 7,61 24,41 8,42 23,06 9,33 21,80 10,33 6 31,52 5,76 29,80 6,30 28,16 6,94 26,60 7,67 25,12 8,50 23,73 9,42 22,41 10,43 8 33,42 5,83 31,59 6,40 29,85 7,06 28,18 7,81 26,60 8,66 25,10 9,60 23,67 10,64 10 35,39 5,93 33,46 6,51 31,60 7,19 29,83 7,97 28,13 8,83 26,52 9,79 24,98 10,84 0 31,43 6,99 29,96 7,48 28,40 8,06 26,74 8,73 24,98 9,50 23,13 10,37 21,18 11,34 2 33,58 7,08 32,01 7,58 30,33 8,17 28,54 8,86 26,66 9,65 24,67 10,52 22,58 11,50 3 34,70 7,12 33,06 7,63 31,32 8,23 29,47 8,93 27,52 9,72 25,46 10,60 23,30 11,58 4 35,83 7,17 34,13 7,69 32,33 8,30 30,41 9,00 28,39 9,80 26,26 10,68 24,02 11,66 5 36,99 7,21 35,23 7,74 33,36 8,36 31,37 9,07 29,28 9,87 27,07 10,76 24,76 11,75 6 38,17 7,26 36,34 7,80 34,40 8,43 32,35 9,14 30,18 9,95 27,90 10,85 25,50 11,84 8 40,59 7,36 38,63 7,92 36,55 8,56 34,34 9,29 32,02 10,12 29,58 11,03 27,01 12,02 10 43,09 7,47 40,99 8,04 38,75 8,70 36,39 9,45 33,91 10,29 31,29 11,21 28,55 12,22 0 35,19 7,95 33,58 8,54 31,87 9,24 30,07 10,05 28,18 10,97 26,20 12,00 24,12 13,14 2 37,56 8,06 35,83 8,68 34,00 9,39 32,07 10,22 30,05 11,16 27,92 12,20 25,70 13,35 3 38,77 8,12 36,98 8,74 35,09 9,47 33,10 10,31 31,00 11,25 28,80 12,30 26,50 13,46 4 40,02 8,18 38,16 8,82 36,20 9,55 34,14 10,40 31,97 11,35 29,70 12,41 27,32 13,57 5 41,28 8,25 39,36 8,89 37,33 9,64 35,19 10,49 32,95 11,45 30,60 12,51 28,14 13,69 6 42,57 8,31 40,58 8,96 38,48 9,72 36,27 10,58 33,95 11,55 31,52 12,62 28,98 13,80 8 45,21 8,45 43,07 9,12 40,82 9,90 38,46 10,78 35,98 11,77 33,39 12,86 30,68 14,05 10 47,93 8,59 45,64 9,29 43,24 10,09 40,71 10,99 38,06 11,99 35,30 13,10 32,41 14,31 16 All copying, even partial, of this manual is strictly forbidden RG66005096 - Rev 02

6 PERFORMANCE 6.1 MTE COOLING CAPACITIES Ta( C) Tev PF PA Outdoor air temperature Evaporation temperature Cooling capacity Total electrical input MTE MTE 038C0 MTE 042C0 MTE 053C0 MTE 059C0 MTE 066C0 MTE 074C0 MTE 082C0 Ta ( C) 15 20 25 30 35 40 45 Tev PF PA PF PA PF PA PF PA PF PA PF PA PF PA 0 40,31 8,47 38,58 9,08 36,68 9,85 34,58 10,77 32,31 11,83 29,85 13,04 27,20 14,40 2 43,03 8,58 41,17 9,21 39,12 9,99 36,87 10,92 34,43 12,00 31,78 13,22 28,95 14,59 3 44,43 8,64 42,51 9,28 40,38 10,07 38,05 11,00 35,51 12,08 32,77 13,31 29,83 14,68 4 45,87 8,71 43,87 9,35 41,66 10,15 39,24 11,09 36,61 12,17 33,78 13,40 30,73 14,78 5 47,33 8,78 45,25 9,43 42,96 10,23 40,45 11,17 37,73 12,27 34,80 13,50 31,64 14,89 6 48,82 8,85 46,66 9,51 44,28 10,31 41,68 11,27 38,87 12,36 35,83 13,61 32,56 15,00 8 51,88 9,00 49,55 9,67 46,99 10,49 44,20 11,46 41,18 12,57 37,92 13,83 34,43 15,23 10 55,04 9,16 52,54 9,85 49,79 10,69 46,79 11,67 43,55 12,79 40,06 14,06 36,33 15,48 0 45,93 9,02 43,68 9,78 41,28 10,70 38,75 11,76 36,08 12,98 33,26 14,35 30,31 15,87 2 49,00 9,11 46,61 9,90 44,07 10,84 41,36 11,92 38,51 13,16 35,49 14,54 32,32 16,06 3 50,59 9,17 48,13 9,97 45,50 10,91 42,71 12,01 39,75 13,25 36,63 14,64 33,35 16,17 4 52,21 9,22 49,67 10,04 46,96 10,99 44,07 12,10 41,01 13,35 37,78 14,74 34,38 16,28 5 53,87 9,28 51,25 10,11 48,44 11,08 45,46 12,19 42,29 13,45 38,95 14,85 35,42 16,40 6 55,56 9,34 52,85 10,18 49,95 11,16 46,86 12,29 43,59 13,56 40,12 14,97 36,47 16,52 8 59,04 9,47 56,14 10,34 53,04 11,35 49,73 12,50 46,22 13,79 42,50 15,22 38,59 16,80 10 62,65 9,61 59,54 10,51 56,22 11,55 52,67 12,73 48,90 14,05 44,92 15,50 40,71 17,10 0 55,58 11,19 53,15 12,04 50,59 13,06 47,88 14,25 45,02 15,61 42,03 17,14 38,89 18,85 2 59,40 11,34 56,80 12,21 54,05 13,25 51,15 14,47 48,10 15,85 44,89 17,40 41,53 19,12 3 61,37 11,41 58,68 12,30 55,83 13,35 52,83 14,58 49,68 15,97 46,36 17,53 42,89 19,26 4 63,38 11,48 60,60 12,39 57,65 13,46 54,55 14,69 51,28 16,09 47,86 17,66 44,27 19,40 5 65,44 11,56 62,55 12,48 59,51 13,56 56,30 14,81 52,95 16,21 49,38 17,80 45,68 19,54 6 67,53 11,63 64,55 12,57 61,40 13,67 58,08 14,93 54,59 16,35 50,93 17,94 47,11 19,69 8 71,84 11,79 68,65 12,76 65,28 13,89 61,73 15,18 58,00 16,62 54,10 18,23 50,03 20,00 10 76,31 11,96 72,89 12,96 69,29 14,12 65,50 15,43 61,53 16,91 57,37 18,54 53,03 20,33 0 62,70 12,42 59,76 13,39 56,63 14,56 53,30 15,92 49,79 17,47 46,08 19,21 42,18 21,14 2 66,99 12,59 63,83 13,60 60,46 14,80 56,89 16,18 53,12 17,75 49,14 19,52 44,96 21,47 3 69,20 12,68 65,93 13,71 62,44 14,92 58,74 16,32 54,83 17,90 50,71 19,67 46,38 21,63 4 71,46 12,77 68,06 13,82 64,45 15,05 60,61 16,46 56,56 18,06 52,30 19,84 47,82 21,80 5 73,77 12,87 70,24 13,93 66,49 15,17 62,52 16,60 58,50 18,22 53,91 20,00 49,27 21,98 6 76,11 12,96 72,46 14,05 68,57 15,31 64,46 16,75 60,12 18,37 55,55 20,18 50,75 22,16 8 80,93 13,17 77,00 14,29 72,83 15,58 68,42 17,06 63,77 18,71 58,88 20,53 53,74 22,54 10 85,91 13,38 81,69 14,54 77,22 15,87 72,49 17,38 67,51 19,06 62,28 20,91 56,79 22,94 0 70,45 14,28 67,22 15,46 63,81 16,86 60,22 18,48 56,44 20,31 52,48 22,37 48,33 24,64 2 75,19 14,51 71,73 15,73 68,08 17,16 64,23 18,81 60,18 20,68 55,93 22,76 51,49 25,06 3 77,63 14,63 74,05 15,86 70,27 17,32 66,28 18,98 62,09 20,86 57,70 22,96 53,11 25,27 4 80,12 14,75 76,41 16,00 72,49 17,48 68,37 19,16 64,04 21,06 59,49 23,17 54,74 25,49 5 82,65 14,87 78,81 16,15 74,76 17,64 70,49 19,34 66,00 21,27 61,31 23,38 56,40 25,72 6 85,23 15,00 81,25 16,30 77,06 17,81 72,64 19,53 68,01 21,46 63,15 23,60 58,08 25,95 8 90,52 15,27 86,26 16,61 81,76 18,16 77,04 19,92 72,09 21,89 66,91 24,06 61,49 26,44 10 95,97 15,55 91,41 16,94 86,60 18,54 81,55 20,34 76,27 22,34 70,74 24,54 64,97 26,95 0 79,76 15,62 76,21 16,94 72,30 18,55 68,02 20,46 63,37 22,66 58,36 25,17 52,97 27,96 2 85,07 15,88 81,25 17,23 77,04 18,87 72,43 20,80 67,43 23,03 62,04 25,56 56,26 28,38 3 87,81 16,02 83,85 17,38 79,47 19,04 74,69 20,99 69,51 23,23 63,92 25,77 57,93 28,60 4 90,61 16,16 86,49 17,54 81,95 19,21 76,99 21,18 71,62 23,43 65,82 25,98 59,61 28,83 5 93,45 16,31 89,17 17,71 84,46 19,40 79,32 21,37 73,74 23,64 67,75 26,21 61,31 29,06 6 96,35 16,47 91,90 17,88 87,01 19,58 81,68 21,58 75,90 23,86 69,69 26,44 63,03 29,31 8 102,29 16,80 97,48 18,25 92,22 19,99 86,48 22,01 80,28 24,33 73,62 26,93 66,48 29,83 10 108,41 17,17 103,23 18,65 97,56 20,42 91,39 22,48 84,74 24,83 77,60 27,47 69,96 30,40 0 90,42 18,09 85,81 19,76 80,92 21,75 75,75 24,04 70,30 26,64 64,57 29,55 58,55 32,77 2 96,38 18,34 91,48 20,06 86,27 22,09 80,74 24,42 74,91 27,06 68,76 30,00 62,30 33,24 3 99,46 18,47 94,40 20,22 89,01 22,28 83,30 24,63 77,26 27,29 70,89 30,24 64,19 33,50 4 102,59 18,61 97,37 20,39 91,80 22,47 85,89 24,85 79,63 27,53 73,03 30,50 66,09 33,77 5 105,79 18,76 100,39 20,57 94,63 22,68 88,51 25,08 82,05 27,77 75,19 30,77 67,99 34,06 6 109,05 18,91 103,46 20,75 97,50 22,89 91,16 25,32 84,45 28,04 77,36 31,05 69,90 34,36 8 115,73 19,24 109,74 21,15 103,35 23,35 96,55 25,83 89,34 28,60 81,73 31,66 73,70 35,01 10 122,61 19,61 116,19 21,59 109,33 23,85 102,02 26,39 94,28 29,22 86,09 32,34 77,46 35,74 RG66005096 - Rev 02 All copying, even partial, of this manual is strictly forbidden 17

6 PERFORMANCE 6.1 MTE COOLING CAPACITIES Ta( C) Tev PF PA Outdoor air temperature Evaporation temperature Cooling capacity Total electrical input MTE MTE 096C0 MTE 108C0 MTE 129C0 MTE 142C0 MTE 163C0 MTE 169C0 MTE 193C0 MTE 214C0 Ta ( C) 15 20 25 30 35 40 45 Tev PF PA PF PA PF PA PF PA PF PA PF PA PF PA 0 106,27 21,33 100,83 23,33 95,09 25,70 89,04 28,44 82,69 31,56 76,04 35,04 69,09 38,90 2 113,18 21,66 107,40 23,71 101,29 26,12 94,83 28,91 88,04 32,07 80,90 35,60 73,42 39,51 3 116,72 21,84 110,78 23,91 104,47 26,35 97,80 29,16 90,76 32,35 83,36 35,90 75,60 39,83 4 120,33 22,03 114,21 24,12 107,70 26,59 100,81 29,42 93,52 32,63 85,85 36,21 77,78 40,16 5 123,99 22,22 117,70 24,34 110,99 26,83 103,86 29,70 96,21 32,93 88,34 36,54 79,94 40,51 6 127,71 22,43 121,25 24,58 114,33 27,09 106,95 29,98 99,12 33,24 90,83 36,87 82,09 40,88 8 135,34 22,88 128,51 25,07 121,14 27,64 113,23 30,59 104,79 33,91 95,81 37,60 86,29 41,66 10 143,21 23,37 135,98 25,62 128,12 28,25 119,61 31,25 110,47 34,63 100,70 38,39 90,28 42,53 0 120,57 24,27 114,18 26,71 107,46 29,58 100,42 32,88 93,06 36,61 85,38 40,77 77,36 45,36 2 128,21 24,74 121,43 27,22 114,28 30,15 106,76 33,50 98,86 37,30 90,60 41,53 81,96 46,20 3 132,12 24,99 125,14 27,50 117,77 30,45 109,99 33,84 101,81 37,66 93,22 41,93 84,24 46,64 4 136,08 25,25 128,91 27,78 121,30 30,76 113,26 34,18 104,77 38,04 95,85 42,35 86,49 47,09 5 140,10 25,52 132,74 28,08 124,89 31,09 116,57 34,54 107,72 38,42 98,46 42,78 88,69 47,57 6 144,17 25,81 136,62 28,40 128,53 31,43 119,91 34,91 110,75 38,85 101,06 43,23 90,83 48,06 8 152,51 26,43 144,55 29,07 135,94 32,16 126,66 35,71 116,72 39,72 106,11 44,18 94,84 49,10 10 161,09 27,11 152,70 29,80 143,49 32,96 133,45 36,58 122,57 40,66 110,87 45,21 98,33 50,23 0 139,01 27,24 132,61 29,62 125,68 32,44 118,22 35,72 110,22 39,45 101,69 43,63 92,63 48,26 2 148,20 27,60 141,38 30,02 133,98 32,90 125,99 36,23 117,43 40,02 108,28 44,26 98,55 48,95 3 152,92 27,79 145,89 30,24 138,24 33,14 129,98 36,50 121,12 40,32 111,64 44,58 101,56 49,31 4 157,73 27,99 150,47 30,47 142,58 33,40 134,04 36,78 124,86 40,62 115,04 44,92 104,58 49,68 5 162,62 28,21 155,14 30,70 146,99 33,66 138,16 37,07 128,74 40,95 118,48 45,28 107,63 50,07 6 167,59 28,43 159,89 30,95 151,48 33,93 142,35 37,37 132,51 41,28 121,95 45,64 110,68 50,47 8 177,78 28,90 169,63 31,47 160,67 34,51 150,90 38,01 140,33 41,98 128,96 46,41 116,78 51,31 10 188,31 29,42 179,67 32,05 170,13 35,14 159,67 38,70 148,30 42,74 136,01 47,24 122,81 52,22 0 153,26 30,89 146,53 33,52 139,07 36,62 130,86 40,20 121,91 44,24 112,22 48,75 101,80 53,73 2 163,46 31,27 156,22 33,97 148,20 37,14 139,38 40,78 129,77 44,90 119,37 49,48 108,18 54,53 3 168,71 31,47 161,21 34,21 152,88 37,42 143,74 41,09 133,78 45,24 123,01 49,86 111,42 54,95 4 174,07 31,68 166,28 34,46 157,65 37,70 148,17 41,41 137,85 45,60 126,69 50,25 114,69 55,38 5 179,53 31,90 171,44 34,71 162,49 37,99 152,67 41,74 141,95 45,95 130,41 50,66 117,99 55,82 6 185,09 32,13 176,69 34,98 167,40 38,30 157,22 42,09 146,14 46,35 134,17 51,08 121,31 56,29 8 196,48 32,62 187,43 35,54 177,44 38,94 166,50 42,81 154,61 47,15 141,77 51,97 127,99 57,26 10 208,24 33,15 198,48 36,15 187,73 39,63 175,97 43,58 163,22 48,02 149,46 52,93 134,71 58,32 0 184,10 38,17 174,72 41,56 164,55 45,49 153,60 49,98 141,86 55,01 129,34 60,59 116,04 66,72 2 195,87 38,96 185,75 42,39 174,79 46,39 163,00 50,95 150,38 56,09 136,92 61,79 122,63 68,05 3 201,90 39,37 191,39 42,83 180,02 46,86 167,79 51,47 154,70 56,65 140,75 62,41 125,95 68,74 4 208,03 39,81 197,11 43,29 185,30 47,36 172,62 52,01 159,05 57,24 144,61 63,06 129,28 69,46 5 214,24 40,26 202,90 43,77 190,65 47,87 177,50 52,56 163,41 57,86 148,48 63,72 132,62 70,19 6 220,54 40,74 208,76 44,27 196,06 48,41 182,43 53,14 167,86 58,48 152,37 64,41 135,95 70,95 8 233,38 41,74 220,69 45,33 207,02 49,55 192,38 54,37 176,76 59,81 160,17 65,87 142,60 72,55 10 246,50 42,83 232,83 46,49 218,13 50,78 202,42 55,70 185,69 61,25 167,94 67,44 149,17 74,25 0 183,30 33,97 174,35 36,74 164,83 40,06 154,75 43,92 144,12 48,34 132,92 53,31 121,17 58,82 2 195,58 34,32 186,08 37,17 175,96 40,56 165,21 44,49 153,85 48,96 141,86 53,97 129,25 59,52 3 201,93 34,50 192,13 37,40 181,68 40,83 170,58 44,80 158,83 49,30 146,42 54,33 133,37 59,90 4 208,42 34,70 198,31 37,64 187,52 41,11 176,04 45,12 163,89 49,65 151,05 54,71 137,52 60,30 5 215,05 34,90 204,61 37,90 193,46 41,41 181,59 45,45 169,06 55,98 155,72 55,11 141,71 60,72 6 221,81 35,12 211,03 38,16 199,50 41,72 187,23 45,80 174,21 50,40 160,44 55,53 145,93 61,17 8 235,73 35,58 224,21 38,72 211,88 42,38 198,73 46,55 184,78 51,24 170,01 56,43 154,43 62,14 10 250,16 36,08 237,83 39,34 224,61 43,10 210,52 47,37 195,55 52,15 179,71 57,44 162,98 63,23 0 212,79 39,68 201,87 43,28 190,35 47,55 178,22 52,49 165,49 58,09 152,15 64,35 138,20 71,28 2 226,60 40,28 215,02 43,96 202,75 48,32 189,80 53,33 176,17 59,02 161,86 65,37 146,86 72,38 3 233,69 40,60 221,77 44,33 209,11 48,72 195,73 53,79 181,62 59,51 166,78 65,91 151,20 72,97 4 240,90 40,94 228,63 44,71 215,58 49,15 201,74 54,26 187,13 60,03 171,73 66,47 155,55 73,58 5 248,23 41,30 235,61 45,12 222,15 49,60 207,84 54,75 192,59 66,20 176,70 67,06 159,86 74,21 6 255,68 41,67 242,70 45,54 228,81 50,07 214,01 55,27 198,30 61,13 181,68 67,67 164,15 74,87 8 270,94 42,48 257,22 46,44 242,42 51,06 226,55 56,36 209,61 62,33 191,60 68,98 172,51 76,29 10 286,68 43,37 272,16 47,42 256,37 52,15 239,30 57,56 220,95 63,65 201,33 70,41 180,43 77,85 0 240,05 46,33 227,22 50,89 213,73 56,25 199,60 62,40 184,82 69,35 169,39 77,08 153,31 85,61 2 255,21 47,21 241,58 51,87 227,21 57,33 212,09 63,60 196,24 70,67 179,64 78,54 162,30 87,22 3 262,96 47,69 248,93 52,39 234,10 57,91 218,46 64,23 202,03 71,36 184,79 79,31 166,74 88,06 4 270,81 48,18 256,38 52,94 241,08 58,51 224,91 64,89 207,85 72,09 189,92 80,10 171,11 88,93 5 278,77 48,71 263,95 53,51 248,17 59,13 231,42 65,58 213,66 78,47 195,02 80,93 175,37 89,84 6 286,84 49,26 271,63 54,11 255,34 59,79 237,98 66,29 219,55 73,63 200,06 81,79 179,49 90,78 8 303,34 50,44 287,30 55,39 269,92 61,18 251,22 67,82 231,19 75,29 209,83 83,61 187,14 92,77 10 320,32 51,73 303,37 56,79 284,75 62,70 264,48 69,48 242,53 77,11 218,93 85,59 193,66 94,94 18 All copying, even partial, of this manual is strictly forbidden RG66005096 - Rev 02

7 SOUND LEVEL Legend: LP A Total sound pressure level, weighted A, measured in an open field, at a distance of 10 m, with a directivity factor of 2. Lw Sound power level by octave band, not weighted Lw A Total sound power level, weighted A Lw Lw A Lp A Modelllo 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz Globale Globale db db db db db db db db (A) db (A) MTE 005 M 72,8 66,5 65,9 61,8 54,6 49,6 45,8 67,0 39,0 MTE 007 M 73,0 66,6 66,0 62,0 54,7 49,7 46,0 67,0 39,0 MTE 009 M 73,0 66,6 66,0 62,0 54,7 49,7 46,0 67,0 39,0 MTE 009 72,6 66,3 65,7 61,6 54,4 49,4 45,6 67,0 39,0 MTE 010 M 74,4 68,0 67,4 63,4 56,1 51,1 47,4 69,0 41,0 MTE 010 74,4 68,0 67,4 63,4 56,1 51,1 47,4 69,0 41,0 MTE 012 74,6 68,3 67,7 63,6 56,4 51,4 47,6 69,0 41,0 MTE 013 75,6 69,3 68,7 64,6 57,4 52,4 48,6 70,0 42,0 MTE 015 76,3 70,0 69,4 65,3 58,1 53,1 49,3 70,0 42,0 MTE 018 83,3 77,0 76,4 72,3 65,1 60,1 56,3 77,0 49,0 MTE 021 83,3 77,0 76,4 72,3 65,1 60,1 56,3 77,0 49,0 MTE 024 83,3 77,0 76,4 72,3 65,1 60,1 56,3 77,0 49,0 MTE 029 85,8 79,4 78,8 74,8 67,6 62,6 58,8 80,0 52,0 MTE 033 85,8 79,4 78,8 74,8 67,6 62,6 58,8 80,0 52,0 MTE 038 85,8 79,4 78,8 74,8 67,6 62,6 58,8 80,0 52,0 MTE 042 87,4 81,0 80,4 76,4 69,1 64,2 60,4 82,0 54,0 MTE 053 79,7 83,5 77,5 76,9 70,0 63,7 62,2 79,0 51,0 MTE 059 79,7 83,5 77,5 76,9 70,0 63,7 62,2 79,0 51,0 MTE 066 79,7 83,5 77,5 76,9 70,0 63,7 62,2 79,0 51,0 MTE 074 79,7 83,5 77,5 76,9 70,0 63,7 62,2 79,0 51,0 MTE 082 79,7 83,5 77,5 76,9 70,0 63,7 62,2 79,0 51,0 MTE 096 80,2 84,0 78,0 77,4 70,5 64,2 62,7 81,5 53,5 MTE 108 80,2 84,0 78,0 77,4 70,5 64,2 62,7 81,5 53,5 MTE 129 80,7 84,5 78,5 77,9 71,0 64,7 63,2 82,0 54,0 MTE 142 80,7 84,5 78,5 77,9 71,0 64,7 63,2 82,0 54,0 MTE 163 80,7 84,5 78,5 77,9 71,0 64,7 63,2 82,0 54,0 MTE 169 81,5 85,3 79,3 78,7 71,8 65,5 64,0 82,8 54,8 MTE 193 81,5 85,3 79,3 78,7 71,8 65,5 64,0 82,8 54,8 MTE 214 81,5 85,3 79,3 78,7 71,8 65,5 64,0 82,8 54,8 RG66005096 - Rev 02 All copying, even partial, of this manual is strictly forbidden 19

8 OPERATING LIMITS The graphs below illustrate the operating limits of MTE (in the case of continuous operation) in relation to the evaporation temperature and outdoor air temperature. WARNING! The units are designed to work with water and air temperatures falling within the range defined by the operating limits. Attempting to operate the units beyond these limits could cause irreparable damage to the units themselves. 8.1 OPERATING LIMITS IN CHILLER MODE STD = standard unit CC = condensation control EEV = electronic expansion valve AIR= outdoor air temperature C T EVAP = evaporation temperature C 20 All copying, even partial, of this manual is strictly forbidden RG66005096 - Rev 02

9 ELECTRICAL DATA AND CONNECTIONS MTE 005 M 007 M 009 M 009 010 M 010 012 013 015 018 021 024 029 033 038 Maximum power input kw 2,4 3,1 4,1 4,1 4,5 4,6 5,9 5,9 6,9 8,6 9,3 10,7 14,0 15,9 17,4 Maximum absorbed current A 12,2 15,7 20,0 7,4 22,8 8,6 10,8 10,9 12,5 16,9 18,0 20,4 28,2 31,4 34,0 Starting current A 63 63 63 45 97 48 63 63 66 73 102 102 130 163 158 Rated power of fan motor kw 0,135 0,135 0,135 0,135 0,135 0,135 0,135 0,135 0,135 0,400 0,400 0,400 0,400 0,400 0,400 Rated power of fan A 0,64 0,64 0,64 0,64 0,64 0,64 0,64 0,64 0,64 1,80 1,80 1,80 1,80 1,80 1,80 Power supply V/ph/Hz 230-1-50 230-1-50 230-1-50 400-3N-50 230-1-50 400-3N-50 400-3N-50 400-3N-50 400-3N-50 400-3N-50 400-3N-50 400-3N-50 400-3N-50 400-3N-50 400-3N-50 Auxiliary power supply V/ph/Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 Cross-section of power cables mm 2 4 6 6 4 10 4 4 4 4 6 6 10 10 10 10 PCD connecting cables mm 2 AWG22 AWG22 AWG22 AWG22 AWG22 AWG22 AWG22 AWG22 AWG22 AWG22 AWG22 AWG22 AWG22 AWG22 AWG22 PCDS connecting cables mm 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Safety fuse F A 16 20 25 10 32 16 20 20 20 25 25 32 40 40 40 Main switch IL A 16 20 25 10 32 16 20 20 20 25 25 32 40 40 40 MTE 042 053 059 066 074 082 096 108 129 142 163 169 193 214 Maximum power input kw 19,2 24,4 26,3 30,1 33,2 37,9 43,4 49,8 54,9 60,1 74,5 75,6 85,4 100,6 Maximum absorbed current A 35,8 45,8 49,2 55,7 60,8 68,8 80,8 90,5 103,3 112,5 136,5 137,1 155,0 174,3 Starting current A 160 167 170 180 196 214 238 276 303 311 382 251 305 322 Rated power of fan motor kw 0,610 0,400 0,400 0,400 0,400 0,400 0,400 0,400 0,400 0,400 0,400 0,940 0,940 0,940 Rated power of fan A 2,65 1,80 1,80 1,80 1,80 1,80 1,80 1,80 1,80 1,80 1,80 2,49 2,49 2,49 Power supply V/ph/Hz 400-3N-50 400-3N-50 400-3N-50 400-3N-50 400-3N-50 400-3N-50 400-3N-50 400-3N-50 400-3N-50 400-3N-50 400-3N-50 400-3N-50 400-3N-50 400-3N-50 Auxiliary power supply V/ph/Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 400-3N-50 400-3N-50 400-3N-50 Cross-section of power cables mm 2 10 16 16 16 16 25 25 35 35 35 50 50 70 70 PCD connecting cables mm 2 AWG22 AWG22 AWG22 AWG22 AWG22 AWG22 AWG22 AWG22 AWG22 AWG22 AWG22 AWG22 AWG22 AWG22 PCDS connecting cables mm 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Safety fuse F A 40 63 63 63 63 80 100 125 125 125 160 160 200 200 Main switch IL A 40 63 63 63 63 80 100 125 125 125 160 160 200 200 - The maximum power input is the mains electricity that must be available in order for the unit to work - The maximum current absorption refers to the current that will trigger the internal safety devices of the unit. It is the maximum current allowed in the unit. This value may never be exceeded; it must be used as a reference for determining the size of the power supply line and the related safety devices (refer to the wiring diagram supplied with the units). Cross-section area of cables: 4 A/mm 2 approx. RG66005096 - Rev 02 All copying, even partial, of this manual is strictly forbidden 21

9 ELECTRICAL DATA AND CONNECTIONS MAIN ELECTRIC CONNECTION OF SINGLE-PHASE AND THREE- PHASE UNITS DIAGRAM SHOWING ELECTRICAL CONNECTIONS BETWEEN MTE AND PCDS REMOTE CONTROL PANEL -FL -IL T2 L2 T1 L1 L N -IG PE -FL L1 L2 L3 N L1 L2 L3 N -IG GENERAL ALRM SIGNAL ON/OFF (STAND-BY) SWITCH ELECTRIC BOARD TERMINAL PCDS POWER SUPPLY L N PE 230 1 50 -IL 2 4 6 N 1 3 5 N PE R STNPE Note: Should the unit go into an alarm status, a voltage of 24V will be present on the terminals of the electric control panel at the terminals 50/24V; where an interface with a voltage-free contact is desired, a relay must be fitted by the installer. 22 All copying, even partial, of this manual is strictly forbidden RG66005096 - Rev 02

10 OVERALL DIMENSIONS MTE MTE 05 09 Legend 1. Gas inlet Ø 16 2. Liquid outlet Ø 12 3. Power supply 4. Electric control board 5. Vibration dampers RG66005096 - Rev 02 All copying, even partial, of this manual is strictly forbidden 23

10 OVERALL DIMENSIONS MTE MTE 10 24 Legend 1 Gas inlet Ø 28 2 Liquid outlet Ø 16 3 Power supply 4 Electric control board 5 Vibration dampers 24 All copying, even partial, of this manual is strictly forbidden RG66005096 - Rev 02

10 OVERALL DIMENSIONS MTE MTE 29 38 Legend 1 Gas inlet Ø 35 2 Liquid outlet Ø 16 3 Power supply 4 Electric control board 5 Vibration dampers RG66005096 - Rev 02 All copying, even partial, of this manual is strictly forbidden 25

10 OVERALL DIMENSIONS MTE MTE 42 Legend 1 Gas inlet Ø 42 2 Liquid outlet Ø 22 3 Power supply 4 Electric control board 5 Vibration dampers 26 All copying, even partial, of this manual is strictly forbidden RG66005096 - Rev 02

10 OVERALL DIMENSIONS MTE MTE 53 82 Legend 1 Gas inlet Ø 35 2 Liquid outlet Ø 22 3 Power supply 4 Electric control board 5 Vibration dampers RG66005096 - Rev 02 All copying, even partial, of this manual is strictly forbidden 27

10 OVERALL DIMENSIONS MTE MTE 96 108 Legend 1 Gas inlet Ø 45 2 Liquid outlet Ø 34 3 Power supply 4 Electric control board 5 Vibration dampers 28 All copying, even partial, of this manual is strictly forbidden RG66005096 - Rev 02

10 OVERALL DIMENSIONS MTE MTE 129 163 Legend 1 Gas inlet Ø 45 2 Liquid outlet Ø 34 3 Power supply 4 Electric control board 5 Vibration dampers RG66005096 - Rev 02 All copying, even partial, of this manual is strictly forbidden 29

10 OVERALL DIMENSIONS MTE MTE 169 214 Legend 1 Gas inlet Ø 58 2 Liquid outlet Ø 31 3 Power supply 4 Electric control board 5 Vibration dampers 30 All copying, even partial, of this manual is strictly forbidden RG66005096 - Rev 02

11 INSTALLATION CLEARANCE REQUIREMENTS To guarantee the proper functioning of the unit and access for maintenance purposes, it is necessary to comply with the minimum installation clearance requirements shown in figures 1, 2, 3, 4 and 5. There must be no obstacles blocking the path of the air flow from the fans. Avoid any and all situations of backflow of hot air between air outlet and inlet of the unit. If even only one of the above conditions is not fulfilled, please contact the manufacturer to check for feasibility. In the design of the MTE series, special care has been taken to minimise noise and vibrations transmitted to the ground. Even greater insulation may be obtained, however, by using vibration damping base supports (available as optional accessories). If vibration damping base supports are adopted, it is strongly recommended also to use vibration damping couplings on the pipes. Whenever the unit is to be sited on unstable ground (various types of soil, gardens, etc.) it is a good idea to provide a supporting base of adequate dimensions. 1 MTE 05 09 EXCHANGER SIDE GAS CONNECTIONS AND ELECTRICAL BOX EXCHANGER SIDE RG66005096 - Rev 02 All copying, even partial, of this manual is strictly forbidden 31

11 INSTALLATION CLEARANCE REQUIREMENTS 2 MTE 10 24 COIL AND GAS CONNECTIONS SIDE ELECTRICAL BOX EXCHANGER SIDE 3 MTE 29 38 EXCHANGER SIDE GAS CONNECTIONS AND ELECTRICAL BOX EXCHANGER SIDE 32 All copying, even partial, of this manual is strictly forbidden RG66005096 - Rev 02

11 INSTALLATION CLEARANCE REQUIREMENTS 4 MTE 042 EXCHANGER SIDE GAS CONNECTIONS AND ELECTRICAL BOX EXCHANGER SIDE 5 MTE 053 214 COIL SIDE 1,5 m FAN COMPARTMENT SIDE 1 m 1 m Retro Fronte ELECTRIC CONTROL BOARD 1,5 m COIL SIDE TOP VIEW RG66005096 - Rev 02 All copying, even partial, of this manual is strictly forbidden 33

12 SITING It is important to bear in mind the following aspects when choosing the best site for installing the unit: - size and origin of water pipes; - Location of the power supply; - Solidity of the supporting surface; - Avoid obstacles to the outflow of air from the fan which could cause back suction (see section on installation clearance requirements ); - Direction of prevalent winds: (position the unit so that prevalent winds do not alter the fan air flow). A prevalent wind blowing from a direction opposite to the fan air flow will reduce the maximum air temperature to a lower value than specified in the operating limits, a wind blowing in the same direction as the fan air flow will increase the minimum air temperature to a higher value than specified in the operating limits. - Avoid the possible reverberation of sound waves; do not install the unit in narrow or cramped spaces; - Ensure adequate accessibility for maintenance or repairs (see section on installation clearance requirements ). - The maximum distance from the indoor unit is 15 m and the difference in height between the two units may not exceed 9 m. This device is not intended to be used by children or by people with physical, sensory or mental impairments, except under supervision. Make sure that children do not have access to the device. 12.1 POSITIONING OF VIBRATION DAMPERS (ACCESSORY) MTE NO. OF VIBR..DAMPERS 05-09 4 10-24 4 29-38 4 42 6 53-82 6 96-108 4 129-163 6 169-214 8 VIBRATION DAMPERS 34 All copying, even partial, of this manual is strictly forbidden RG66005096 - Rev 02

13 COOLING CIRCUIT DIAGRAMS Legend N COMPONENT SIMBOL 1 Compressor 2 Evaporator 3 Condensator 4 Thermostatic valve 5 Electrical fan 6 Filter 7 Sight glass 8 Solenoid valve 9 High pressure switch 10 Low pressure switch 11 High pressure gauge 12 Low pressure gauge 13 Service connection 14 Diff. pressure switch 15 Check valve 16 4 Way diversion valve 17 Liquid separator 18 Liquid receiver 19 Pressure transducer 20 Liquid distributor 21 Oil pressure switch 22 Desuperheater 23 Shut-Off valve 24 Pocket 25 Security valve 26 Fusible plug 27 Flow switch 28 Restrictor 29 Electronic expansion valve RG66005096 - Rev 02 All copying, even partial, of this manual is strictly forbidden 35

13 COOLING CIRCUIT DIAGRAMS MTE 07 (SEE TABLE 1.) MTE 09 38 (SEE TABLE 1.) TABLE 1 COMPONENT NOTE 11 High pressure gauge Not available for MTE 09 12 Low pressure gauge Not available for MTE 09 36 All copying, even partial, of this manual is strictly forbidden RG66005096 - Rev 02

13 COOLING CIRCUIT DIAGRAMS MTE 42 ONLY FOR MODELS FROM 108 TO 163 MTE 53 163 ONLY FOR MODEL 163 RG66005096 - Rev 02 All copying, even partial, of this manual is strictly forbidden 37

13 COOLING CIRCUIT DIAGRAMS MTE 169 214 38 All copying, even partial, of this manual is strictly forbidden RG66005096 - Rev 02

NOTES RG66005096 - Rev 02 All copying, even partial, of this manual is strictly forbidden 39

www.galletti.it 40010 Bentivoglio (BO) - Italy - Via Romagnoli 12/a Tel. +39 051 8908111 - Fax. +39 051 8908122 Company UNI EN ISO 9001 and OHSAS 18001 certified