MAXIMUM SERIES. Maximum Series portable chillers can be used on a variety of process applications that require 20 F to 70 F chilled water.

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

MACH N-407 Heat Pump Air-Cooled Chiller

OACS Outdoor Air-Cooled Central Chillers

.2 Section Waste Management and Disposal.

TTOACS SERIES. Air-Cooled GREAT FOR NEW START-UP INSTALLATIONS OR EXPANSION OF EXISTING SYSTEMS...

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

SERIES. OACS Series central chiller can be used on a variety of process applications that require 20 F to 70 F chilled water.

MAC N-407 Air-Cooled Chiller

Call us today! (800)

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

GP SERIES Packaged Chillers

Call us today! (800)

STACT. Model Designations. Model Number: STACT8S6. ST = Portable Scroll Chiller. AC = Air Cooled WC = Water Cooled. T = With Process Tank

THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE.

Call us today! (800)

VariCool VAV Engineering Guide

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

EC MODEL. EC Model & Split Systems Water Source Heat Pump. 6 to 30 tons

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-120HE-03 Air-Cooled Chiller

30GT FLOTRONIC AIR-COOLED CHILLERS

ORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e.

THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE.

Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

RQE Series Temperature Controllers

60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Ultimate energy saving technology

2 shp 13 lc 1 36 t - 1 a

Temptek Auxiliary Equipment

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

RECORD SUBMITTAL COVER SHEET

precision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs

30RB /30RQ

30GN FLOTRONIC II AIR-COOLED CHILLERS

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

CENTRAL SPLIT UNIT UNIC

TRIDENT GS SERIES Central Chiller

SECTION ROTARY-SCREW WATER CHILLERS

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

water to water heat pumps

WZT High Efficiency Air to Water Split System Heat Pumps With E.V.I. Compressors

C13-Series Engineering Guide

Refrigerated Air Dryers

Air-Cooled Condensing Units with Compact Screw Compressors

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS

Date: August 21, Proposal Number: G Engineer: Payment Terms: Net 30 Days

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

YOUR PROCESS DEMANDS THE MOST DEPENDABLE TEMPERATURE CONTROL UNIT AVAILABLE.

Refrigerated Compressed Air Dryers

Water-Cooled Modular Chillers. Product Data Catalog. Standard and Total Access Modules MS010X, MS015X, MS020X, MS030X, MS040X, MS050X, MS070X, MS085X

MEDICAL CHILLER SYSTEMS

TECHNICAL SPECIFICATIONS

PACKAGED AIR COOLED Product Data Catalog

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons

Refrigerated Compressed Air Dryers 5-6,000 scfm

Heat Pumps COMFORT NEED IT. When You

120D, 150D, 190D, 240D, 370B. How to Order 220V 240V 400V 440V. Note 1) Select one applicable voltage. Voltage. Voltage. Symbol. Model 370B 220V 240V

Refrigerated Dryers. Cycling; Non-Cycling; High Pressure; High Temperature ,000 scfm

HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, , 18, 20, and 25 NOMINAL TONS

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

CF-10A shown CF- 2A Shown

Air-Cooled Global Chiller

Pathfinder Air-Cooled Single-Screw Chiller/Heat Pump

MLC Air Cooled Chillers MLC-FC Free Cooling Chillers MLC-AD Adiabatic Chillers

1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC.

ULTIMATE ENERGY SAVING TECHNOLOGY

PDF Created with deskpdf PDF Writer - Trial ::

50TM TFF COMBINATION HEATING/COOLING UNITS

Product Data. Features/Benefits ComfortLink control

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

30 F to 300 F Process Temperatures* 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 3/8-1 Solenoid Cooling Valves (VE & 300 F models)

LZT LZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSION ACCESSORIES

SENTRA Series Water Unit

50TM COMBINATION HEATING/COOLING UNITS

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

Ultimate energy saving technology

Product Chillers A P P L I C AT I O N S

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES CC COMPACT PACKAGED CHILLERS PART 1 GENERAL

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

Refrigerated Air Dryers

ESP. Variable Speed Heat Pump. Installation and Operation. 3 Ton ESP Ton ESP-60

Please record your equipment s model and serial number(s) and the date you received it in the spaces provided.

AIR COOLED PACKAGED CHILLER

Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS. Technical Bulletin. Products that provide lasting solutions.

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

WO P NF L M 407c Spec Submittal

Nirvana. Cycling Refrigerated Dryers

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

WO P NF L M 407c Spec Submittal

Transcription:

PORTLE HILLER4EP2 SERIES Outstanding Performance; pplication Flexibility EP2 Series Portable hillers are designed for 4 to 43 ton applications. Units are available in air-cooled, water-cooled and remote condensers models in a wide range of sizes. Using quality components such as scroll compressors, microchannel condensers, low noise fans, stainless steel brazed plate evaporators and sophisticated controls provide the best available technologies for unmatched performance and reliability in a chiller package. Integrated with R-410 non-ozone depleting refrigerant, the EP2 series functions with the environment in mind. Dependable, Easy-to-Use, Wide Size Range Model EP2-05 (air-cooled, 5 ton capacity) The EP2 Series offers superior performance and innovative technology in a dependable portable chiller package. This series of chillers boasts the best components and technology available for the highest level of performance and flexibility to meet the needs of today s industrial manufacturing environment. Designed for total efficiency, all air-cooled models have tools-free removable door panels for easy access to all components. onair s EP2 air-cooled units also feature high-efficiency, low noise fans with integral condensers for reduced operating noise and increased efficiency. lso included as standard are totally enclosed air over (TEO) motors that contribute to the long life of the chiller. `` vailable with optional touchscreen control The EP2 Series Portable hillers come with a standard controller, with 19 operational and diagnostic lights, or can be upgraded to include the new premium touchscreen controller with operational and diagnostic screens for easier diagnosis of faults. oth controls are easy to operate and completely sealed to protect against contamination from dirt or fluids. `` More standard features The EP2 models come equipped standard with features that other manufacturers would offer as options, features that guarantee long life, simple operation and quality end-results. `` Energy efficient Reliable and energy efficient scroll compressors are used in every EP2 chiller. Units over 20 tons utilize compressor staging for reduced energy use. Save even more energy with the variable speed compressors available on 10-ton and 20-ton ir- ooled and Water-ooled units! See the savings in the Payback section of this spec sheet. These onair chillers save you money by saving energy. `` Extensive warranty In addition to onair s standard one year parts and labor warranty, the EP2 comes with a five year parts warranty for the PL controller and interface, and a lifetime $175 exchange policy after the initial five year warranty period (on the standard board).

PORTLE HILLER4EP2 SERIES TPHX046-0917 ontrol Features Standard control features: Optional control features: Start-to-start anti-cycle timer prevents shortcycling of compressor while minimizing off periods Panasonic PL with touchscreen interface for enhanced diagnostic and operational display capabilities djustable deviation alarm timer delay to prevent nuisance alarms during start-up Display temperatures easily switched from F to Display of compressor and pump running hours helps with maintenance scheduling 3-phase monitor protects against unit damage due to phase reversal or loss of phase Master reset function to restore factory defaults ontrol Features Our most advanced controller option comes with a Panasonic PL that features operational and diagnostic screens with a touch screen interface. ontroller display screens are easy to read and easy to operate. This sophisticated controller option guarantees maximum chiller performance and reliability. Refrigeration pressure transducers with sensor fault alarms (with PL) Setpoint ambient tracking or remote control Hand-held, remote control operator panel SPI, Modus RTU, net, and LonWorks communication capability Variable speed compressor (10 and 20 ton units)

PORTLE HILLER4EP2 SERIES TPHX046-0917 Features 01 luminum microchannel condensers for easier maintenance and improved reliability (air-cooled models) 04 02 01 Stainless steel brazed plate evaporator provides higher heat transfer coefficients due to reduced fouling 02 03 Y-strainer to protect evaporator from contamination 03 04 Rotary non-fused disconnect switch Mechanical features Stepper motor driven hot gas bypass for reliable and precise temperature control Freezestat safety integrated into password protected menu to reduce risk of tampering provides evaporator freeze-up protection ir-cooled units with generously sized air-cooled condensers designed for industrial environments and tested to 700 PSIG {48 bar}. Includes air inlet filters. ondenser fan blade, motor, nozzle, and guard are a single piece assembly for improved reliability. The fan motors have a rugged external rotor design with totally enclosed air over construction Encapsulated high and low refrigerant pressure safeties Water-cooled units use cleanable shell-and-tube water cooled condensers for industrial environments. Units are equipped with condenser water regulating valve to provide constant head pressure Remote condenser units are designed with divided fan sections which prevent wind-milling during fan cycling, that include galvanized steel fan sections and coil baffles, copper tube / aluminum fin coils tested to 650 PSIG {45 bar}, and direct drive multi-blade propeller fans with venture orifices to optimize efficiency External sight glass / fill connection / drain connection RTD temperature sensors yield higher precision and repeatability than thermocouples Nonferrous water circuit construction Stainless steel process pump with pressure gauge Fail safe flow switch interlocked with compressor Internal valved bypass line to protect pump and evaporator Internal insulated polyethylene reservoir comes with large capacity and a removable top Smaller footprint takes up less floor space than chiller units from other manufacturers Easily removable side panel allows for quick access to internal components

PORTLE HILLER4EP2 SERIES How it Works Process circulation: Process fluid enters through the From process and enters the evaporator. The process fluid is cooled in the evaporator and is returned to the tank. The pump draws water from the tank and delivers it to the To Process connection where it is distributed to the process load(s) and returned to the chiller. Refrigerant circulation: The evaporator extracts heat from the process fluid. Vaporized refrigerant travels from the evaporator to the compressor, where it is compressed. The high-pressure vapor travels to the condenser. ir or water removes heat from the vapor, condensing it to liquid. This liquid is metered back to the evaporator by the expansion valve (TXV). Options High pressure switch Low pressure HP switch LP ompressor ir, water or remote condenser Thermal expansion valve Filter Hot gas bypass valve Evaporator L Level switch Supply process temperature Process fluid flow switch FS Y-strainer Tank Optional make-up water solenoid valve Freezestat FZ Make-up water Pump Guage Optional return process temperature ypass valve From process To process Oversized pumps for increased process fluid flows and/or pressures High flow unit design for reduced internal pressure loss at higher processes fluid flows larm horn larm relay Rotary non-fused or fused disconnection switch -UL508 industrial control panel construction Extended condenser air range (0 F to 110 F) High temperature condenser air range (60 F to 122 F) Low temperature condenser air range (-20 F to 110 F) Wide temperature condenser air range (0 F to 122 F) Remote air-cooled condenser coil coating for installations near coastal regions Pump and tank deduct for applications that do not require the standard internal pump and tank Oversized reservoirs Water circuit designed for use with de-ionized water Stainless steel cabinetry for special applications such as food processing plants utomatic electric water make-up valve for applications requiring automatic fluid make-up High pressure variable-speed fans for air-cooled condenser chillers for ducting of discharge air Modbus RTU, net, LonWorks, or SPI communications ports 4 to 20 m cooling supply temperature retransmit Emergency stop button to provide a quick means of stopping the chiller Hand-held remote controller with 50 foot wire to duplicate unit mounted controls Special color paint for applications requiring the chiller match the color of other equipment Optional PL ontroller with 7-inch Touchscreen HMI PL with touchscreen interface for enhanced diagnostic and operational display capabilities Refrigeration pressure transducers with fault alarms (requires PL option) Process flow meter with digital flow display on the touchscreen interface (requires PL option) Set point ambient tracking or remote control for specialize process applications 3-way water temperature control valve for isolation heat exchangers (requires PL option)

PORTLE HILLER4EP2 SERIES Options Variable-Speed Scroll ompressors (10 and 20 ton Water-ooled and ir-ooled chillers only) Industrial portable chillers operate in a variety of applications with process heat loads frequently less than 100% of available capacity. With increasing emphasis on energy efficiency and reduced operating costs, we developed a variable-speed scroll compressor option to help improve the efficiency of our industrial portable chillers. Most portable chillers use fixed-speed scroll compressors with hot gas bypass to provide capacity and temperature control. This valve bypasses a portion of the hot discharge refrigerant gas back into the compressor to give the compressor a simulated 100% load situation. Payback 10-Ton ir-ooled Variable-Speed ompressor Option Payback (Years based on $0.10/kWHr power cost) Hours/Year ased on 50 Weeks/Year 4,000 hours/year (16 hours/day, 5 days/week) 6,000 hours/year (24 hours/day, 5 days/week) 8,400 hours/year (24 hours/day, 7 days/week) This works well to keep the compressor running and ready for any fluctuations in the actual process load; however, it runs the compressor at full speed all the time. Our variable-speed scroll compressor technology varies the compressor speed to match the process load. y automatically adjusting the compressor speed, the chiller works only as hard as necessary to provide optimum performance with significantly reduced power use. Process Load as Percent of vailable hiller apacity 50% 55% 60% 65% 70% 75% 80% 85% 90% 1.1 1.2 1.3 1.4 1.6 1.9 2.4 3.2 5.1 0.7 0.8 0.9 1.0 1.2 1.6 2.1 3.4 0.5 0.6 0.7 0.9 1.1 1.5 2.4 20-Ton ir-ooled Variable-Speed ompressor Option Payback (Years based on $0.10/kWHr power cost) Hours/Year ased on 50 Weeks/Year 4,000 hours/year (16 hours/day, 5 days/week) 6,000 hours/year (24 hours/day, 5 days/week) 8,400 hours/year (24 hours/day, 7 days/week) Process Load as Percent of vailable hiller apacity 50% 55% 60% 65% 70% 75% 80% 85% 90% 1.4 1.5 1.8 2.2 3.3 6.5 0.9 1.0 1.2 1.5 2.2 4.4 0.7 0.8 1.1 1.6 3.1 10 -Ton hiller Energy Use 20 -Ton hiller Energy Use 10 -Ton hiller Energy Use 100% 100% 100% 90% 90% 90% Power Use (% of Full Load Power) 80% 70% 60% 50% Energy Savings Power Use (% of Full Load Power) 80% 70% 60% 50% Power Use (% of Full Load Power) 80% 70% 60% 50% 40% 30% 30% 40% 50% 60% 70% 80% 90% Load Percentage (% of Full apacity) Fixed Speed ompressor (Hot Gas ypass apacity ontrol) Variable Speed ompressor (Variable Speed apacity ontrol) 40% Energy Savings 30% 30% 40% 50% 60% 70% 80% 90% Load Percentage (% of Full apacity) Fixed Speed ompressor (Hot Gas ypass apacity ontrol) Variable Speed ompressor (Variable Speed apacity ontrol) 40% 30% 30% 40% 50% 60% 70% 80% 90% Load Percentage (% of Full apacity) Fixed Speed ompressor (Hot Gas ypass apacity ontrol) Digital ompressor (Digital Unloader apacity ontrol) Variable Speed ompressor (Variable Speed apacity ontrol)

Pump urves Water temperature at 50 F {10 } PORTLE HILLER4EP2 SERIES EP2 Series Pump urves (60 Hz) Flow (lpm) 120.0 110.0 100.0 5 Hp 2-stage 90.0 80.0 Pressure (bar) 70.0 60.0 50.0 3 Hp 2-stage 40.0 30.0 3 Hp 2 Hp 5 Hp 7½ Hp 10 Hp 20.0 1½ Hp 10.0 0.0 0 20 40 60 80 100 120 140 160 Flow (gpm) Specification Notes Pump availability: 1-1/2 Hp {1.12 kw} pump standard for 4, 5, 8; 2 Hp {1.49 kw} pump standard for 10 and 13 ton units; 3 Hp {2.24 kw} pump standard for 15 ton units and optional for 4, 5, 8, 10 and 13 ton units; 3 Hp {2.24 kw} 2-stage pump optional for 4 and 5 ton units; 5 Hp {3.73 kw} pump standard for 20, 25, 30, 35 and 40 ton units and optional for 8, 10, 13, 15 and 20 ton units; 5 Hp {3.73 kw} 2-stage pump optional for 4 and 5 ton units; 7-1/2 Hp {5.60 kw} pump optional for 8, 10, 13, 15, 20, 25, 30, 35 and 40 ton units; 10 Hp {7.46} pump optional for 15, 20, 25, 30, 35 and 40 ton units. Pump curves do not reflect pressure drops due to internal piping. These pump curves are non-overloading using the service factor of the motors. Specifications may change without notice. heck with your onair representative for the most current information.

PORTLE HILLER4EP2 SERIES TPHX046-0917 Specifications ir cooled: EP2-04, EP2-05, EP2-08, EP2-10 and EP2-13 Rear view (EP2-04 and EP2-05) (EP2-08, EP2-10 and EP2-13) ir cooled: EP2-15 and EP2-20 Rear view (EP2-15) (EP2-20) ir cooled: EP2-25 and EP2-30 Rear view (EP2-25) (EP2-25)

PORTLE HILLER4EP2 SERIES Specifications Water cooled: EP2W-05, EP2W-08, EP2W-10 and EP2W-15 Remote condenser (indoor unit): EP2R-05, EP2R-08, EP2R-10 and EP2R-15 Rear view (EP2W-05 and EP2R-05) (EP2W-08, EP2W-10, EP2W-15, EP2R-08, EP2R-10 and EP2R-15) Water cooled: EP2W-20, EP2W-25, EP2W-30, EP2W-35 and EP2W-40 Remote condenser (indoor unit): EP2R-20, EP2R-25, EP2R-30, EP2R-35 and EP2R-40 Rear view Remote condenser (outdoor unit) : Used with models EP2R-05, EP2R-08, EP2R-10,EP2R-15, EP2R-20, EP2R-25, EP2R-30, EP2R-35 and EP2R-40 (EP2R-05 and EP2R-08) (EP2R-10,EP2R-15 and EP2R-20) (EP2R-25 and EP2R-30) (EP2R-35 and EP2R-40)

PORTLE HILLER4EP2 SERIES Specifications Models EP2-04 EP2-05 EP2-08 EP2-10 EP2-13 EP2-15 EP2-20 EP2-25 EP2-30 ondenser ir cooled Performance characteristics ooling capacity tons* 4.4 5.1 7.8 11.0 12.5 14.9 20.9 25.6 30.6 Setpoint range F { } 20 to 80 {-7 to 27} Refrigerant R410 ondenser ir flow ft 3 /min 4000 8000 10,450 18,000 20,000 24,000 Sound pressure d @ 1 meter 73.8 74.0 75.8 76.2 82.2 84.4 85.9 Minimum unloaded capacity tons 1.0 1.2 1.8 2.7 3.1 3.6 4.8 6.0 7.2 Standard pump performance Pump motor size Hp {kw} 1.5 {1.1} 2 {1.4} 3 {2.2} 5 {3.7} Pump flow gpm {l/min} 11 {42} 12 {45} 19 {72} 27 {102} 30 {114} 36 {136} 48 {182} 60 {227} 72 {273} Net pump pressure psi {bar} 38 {2.6} 39 {2.6} 37 {2.5} 38 {2.6} 35 {2.4} 43 {2.9} 50 {3.4} 48 {3.3} Dimensions inches {mm} - Height with standard fans 61 {1549} 94 {2388} - Height with high pressure fans N/ 63 {1600} 96 {2438} - Width 35 {889} 41 {1041} - Depth 48 {1219} 75 {1905} 87 {2210} 105 {2667} Power requirements M 460/3 phase/60 Hz 16 18 26 31 37 44 58 70 83 MOP 460/3 phase/60 Hz 25 30 45 60 70 80 100 125 Water requirements Reservoir holding capacity gal {l} 11 {42} 22 {83} 40 {151} 50 {189} 67 {254} Process connections (NPT) inches 1.5 2.0 Weight lb {kg} Shipping 720 {327} 1195 {542} 1215 {551} 3200 {1451} 3300 {1497} 3800 {1724} 4150 {1882} Models EP2W-05 EP2W-08 EP2W-10 EP2W-15 EP2W-20 EP2W-25 EP2W-30 EP2W-35 EP2W-40 ondenser Water cooled Performance characteristics ooling capacity tons* 5.5 8.1 12.0 16.5 22.6 28.1 33.3 38.9 43.4 Setpoint range F { } 20 to 80 {-7 to 27} Refrigerant R410 ondenser water flow gpm {l/min} 17 {64} 24 {91} 36 {136} 48 {182} 65 {246} 82 {310} 96 {363} 111 {420} 124 {469} Sound pressure d @ 1 meter 69.8 70.3 71.3 73.3 73.7 74.7 76.6 78.1 Minimum unloaded capacity tons 1.3 1.9 2.9 3.9 5.2 6.6 7.8 8.9 9.9 Standard pump performance Pump motor size Hp {kw} 1.5 {1.1} 2 {1.4} 3 {2.2} 5 {3.7} Pump flow gpm {l/min} 13 {49} 20 {76} 29 {110} 39 {148} 54 {204} 67 {254} 79 {299} 92 {348} 102 {386} Net pump pressure psi {bar} 37 {2.5} 36 {2.5} 35 {2.4} 40 {2.7} 45 {3.1} 46 {3.1} 44 {3.0} 41 {2.8} 38 {2.6} Dimensions inches {mm} - Height 54 {1372} 47 {1194} - Width 35 {889} 41 {1041} - Depth 48 {1219} 75 {1905} 87 {2210} 105 {2667} Power requirements M 460/3 phase/60 Hz 16 23 28 40 49 61 69 74 78 MOP 460/3 phase/60 Hz 30 40 50 70 90 100 110 Water requirements Reservoir holding capacity gal {l} 11 {41.6} 22 {83} 50 {189} 67 {254} Process connections (NPT) inch 1.5 2.0 2.5 ondenser connections (NPT) inch 1.5 2.5 3.0 Weight lb {kg} Shipping 720 {327} 1195 {542} 1315 {596} 1900 {862} 2100 {953} 2250 {1021} 3400 {1542} 3900 {1769} Specification Notes ll specifications listed here reflect the standard product as configured with standard pump, evaporator, and hardware, and operating at environmental levels as noted below. For a more detailed list of specifications for unique circumstances or including EP2 options, refer to the onair EP2 Product Data booklet, available on the onair website or from your onair representative. * ooling tons based on 12,000 TUH with 50 F {10 } leaving coolant and 85 F { } condenser water. Sound power shown is for standard high-efficiency constant speed fan motors. high pressure varibale speed E motor fan option is available for EP2 and larger units. Net available pressure at outlet of chiller is pump discharge pressure less the internal pressure loss through the fluid circuit. M is Minimum ircuit mps with standard condenser fan(s) and pump under full load, used for minimum wire size requirement. MOP is Maximum Overcurrent Protection with standard condenser fans(s) and pump, used for sizing main power protection devices. Standard units are design for 5K SR (short circuit current rating) RMS symmetrical amps. Specifications may change without notice. onsult a onair representative for the most current information.

PORTLE HILLER4EP2 SERIES Specifications ll specifications listed here reflect the standard product as configured with standard pump, evaporator, and hardware, and operating at environmental levels as noted below. For a more detailed list of specifications for unique circumstances or including EP2 options, refer to the onair EP2 Product Data booklet, available on the onair website or from your onair representative. Models* (indoor unit) EP2R-05 EP2R-08 EP2R-10 EP2R-15 EP2R-20 EP2R-25 EP2R-30 EP2R-35 EP2R-40 ondenser Remote air cooled Performance characteristics ooling capacity tons 5.3 7.6 11.0 15.3 20.8 25.8 30.7 35.5 39.9 Setpoint range F { } 20 to 80 {-7 to 27} Refrigerant R410 Sound pressure d @ 1 meter 69.8 70.3 71.3 73.3 73.7 74.7 76.6 78.1 Minimum unloaded capacity tons 1.2 1.8 2.7 3.6 4.8 6.0 7.2 8.4 9.6 Standard pump performance Pump motor size Hp {kw} 1.5 {1.1} 3 {2.2} 5 {3.7} Pump flow gpm {l/min} 13 {49} 18 {68} 27 {102} 36 {136} 48 {182} 61 {231} 73 {276} 83 {314} 92 {348} Net pump pressure psi {bar} 35 {2.4} 36 {2.5} 30 {2.1} 48 {182} 39 {2.7} 57 {3.9} 54 {3.7} 53 {3.7} 50 {3.4} Dimensions inches {mm} - Height 54 {1372} 47 {1194} - Width 35 {889} 41 {1041} - Depth 48 {1219} 75 {1905} 87 {2210} 105 {2667} Power requirements M 460/3 phase/60 Hz 16 23 28 40 49 61 69 74 78 MOP 460/3 phase/60 Hz 30 40 50 70 90 100 110 Water Requirements Reservoir holding capacity gal {l} 11 {41.6} 22 {83} 50 {189} 67 {254} Process connections (NPT) inches 1.5 2 2.5 Refrigerant liquid line size in inch 0.625 0.875 1.125 1.375 Refrigerant discharge line size in inch 0.625 0.875 1.125 1.375 Weight lb {kg} Shipping 720 {327} 1195 {542} 1315 {596} 1900 {862} 2100 {953} 2250 {1021} 3400 {1542} 3900 {1769} Models* (outdoor unit) EP2R-05 EP2R-08 EP2R-10 EP2R-15 EP2R-20 EP2R-25 EP2R-30 EP2R-35 EP2R-40 ondenser Remote condenser Performance characteristics ondenser air flow ft 3 /min 6870 6620 14400 24000 22600 20600 33900 32000 30900 Sound pressure d @ 3 meters 60.0 62.0 72.0 73.0 Dimensions inches {mm} - Height 48.125 {1222} 54 {1372} - Width 43.625 {1108} 45.625 {1159} - Depth 53.625 {1362} 93.625 {2378} 125.750 {3194} 180.750 {4591} Power requirements ** M 460/3 phase/60 Hz 1.4 2.6 7 10.1 MOP 460/3 phase/60 Hz 15 Water Requirements Refrigerant liquid line size in inch 0.875 1.375 2.125 2.625 Refrigerant discharge line size in inch 1.125 1.375 1.625 2.625 Weight lb {kg} Shipping 245 {111} 265 {120} 415 {188} 680 {308} 720 {327} 1050 {476} 1075 {488} 1175 {533} 1450 {658} Specification Notes * Remote condenser operation requires both indoor and outdoor unit. ooling tons based on 12,000 TUH with 50 F {10 } leaving water temp. and 95 F {32 } ambient air temperature. Net available pressure at outlet of chiller is pump discharge pressure less internal coolant circuit pressure losses. M is Minimum ircuit mps with standard pump under full load, used for minimum wire size requirement. MOP is Maximum Overcurrent Protection with standard pump, used for sizing main power protection devices. Standard units are design for 5K SR (short circuit current rating) RMS symmetrical amps. ** ondenser power requirements may require two independent wiring drops for dual refrigerant circuit systems. heck condenser installation manual for specific wiring requirements before installation. Specifications may change without notice. onsult a onair representative for the most current information.