Qualifying Gas Food Service Equipment (AU and OPU Customers Only) 1/1/17

Similar documents
FOOD SERVICE EQUIPMENT REBATES

innovation inspiration

for Energy & Water Savings in Commercial Food Service

Energy & Water Savings in Commercial Food Service

LABEL PLEASE NOTE: ALL APPLICATIONS AND SITE PLANS MUST BE COMPLETED IN BLACK OR BLUE INK ONLY

ENERGY STAR SOLUTIONS FRYERS GRIDDLES OVENS STEAM COOKERS. [P]

Demand-Controlled Ventilation for Commercial Kitchen Ventilation

REQUIREMENTS FOR HOOD PLANS

Bevier Sustanability Bevier Hall 905 S Goodwin Urbana, IL 61801

Case Studies: Restaurant Energy Efficiency. hosted by:

LACLEDE ENERGY EFFICIENCY PROGRAMS

REFRIGERATION Open case to New Reach-in Low or Medium Temperature Low Temp Coffin to New High Efficiency Reach-In...

Innovative Technologies [and Design Concepts] in Commercial Foodservice

Breen Auction Group Pty Ltd AUCTION CATALOGUE

New Era in Energy Efficiency!

Demand Control Ventilation What, When and Where?

Demand Controlled Kitchen Ventilation (DCKV) [Strategy]

Getting the Heat. Out of the Kitchen

Why ENERGY STAR? ENERGY STAR is a voluntary partnership between EPA and industry organizations.

Food Service Technology Center Promoting Energy Efficiency in Food Service

Mobile Vendors Bulletin

MECHANICAL EXHAUST VENTILATION SYSTEMS OPERATIONAL GUIDELINES-REVISED 2003

Commercial Kitchen Exhaust Requirements Kitchen Exhaust for Food Service Operations

AM SELECT WAREWASHER. The ENERGY STAR rated door-type AM Select warewasher is the only warewasher you need.

EUCCW SERIES. EUCCW4, EUCCW6 and EUCCW8 Upright 29 Conveyor Dual Rinse Dishwashing Machine. Champion, an Ali Group Company

EUCCW SERIES Upright 29" Conveyor Dual Rinse Dishwashing Machine

Food Service Technology Center

Absolute Public Auction

EUCC SERIES Upright 24" Conveyor Dual Rinse Dishwashing Machine

General Session Lab Meets the Real World: Case Studies of Energy Efficient Upgrades that Saved Money

Model 80 DRHDPW 44 Single Tank with 36 Heavy Duty Prewash High Temperature Rack Conveyor Dishwashing Machine with

Application and Terms and Conditions

Demand-Controlled Ventilation For Commercial Kitchens

EUCCW SERIES Upright 29" Conveyor Dual Rinse Dishwashing Machine

Product Presentation. Prover/Retarder/Freezer

Public Auction. Bar & Restaurant. Absolute Public Auction!!! Tuesday, July 17th, (317) Fax: (317)

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

CARL S JR REPLACEMENT PARTS FOR STORE LEVEL REFRIGERATION EQUIPMENT --PREPARATION EQUIPMENT COOKING EQUIPMENT SERVING EQUIPMENT MISCELLANEOUS

TECHNOLOGY AND MARKET ASSESSMENT FORUM: NATIONAL ACCOUNT PRESENTATION Presented by Melisa Marks October 26, 2011

Product Presentation. Prover/Retarder/Freezer

SDG&E s Business Energy Solutions Program 2018 Product Catalog

The (Hot) Water Efficient Commercial Kitchen. Charles M. Bohlig East Bay Municipal Utility District

Food Service Technology Center

If it looks as if it could be in a restaurant kitchen, well,

Durable, MIG welded construction. Flashtube pilot system can save up to $300 per year in gas consumption

Natural Gas Energy Efficiency Program. The Hotel/Lodging Industry

FT1000S ENERGY RECOVERY STEAM Flight-Type Dishwashing Machine FT SERIES FT1000S ENERGY RECOVERY STEAM STANDARD FEATURES SPECIFIER STATEMENT

CT PROformance COMBITHERM

MODEL 86 PW MODEL 86 PW RACK CONVEYOR STANDARD FEATURES SPECIFIER STATEMENT. Project Item No. Quantity

Low Wall Back Shelf Exhaust Canopy

David Reynolds, Business Development Manager. Halton Group Foodservice Division

The secrets to our success? Not so secret. How do you keep customers loyal? Keep giving them what they need. Exclusive technical innovations.

CT PROformance COMBITHERM

Public. Auction. Absolute Public Auction!!! (317) Fax: (317) Tuesday January 26th

PUBLIC AUCTION. Absolute Public Auction!!! Restaurant, Banquet, Bar & Bakery Equipment

FT1000 ENERGY RECOVERY STEAM WITH BLOWER DRYER Flight-Type Dishwashing Machine FT SERIES FT1000 ENERGY RECOVERY STEAM WITH BLOWER DRYER

New! Refrigerator FEATURES

Designing and Operating an Energy Efficient Foodservice Facility March 12, 2014 Winnipeg, MB

Durable, MIG welded construction. Flashtube pilot system can save up to $300 per year in gas consumption

MSYS 4490 AC Systems

If searching for the ebook Rotary oven manual in pdf form, then you've come to the faithful site. We furnish complete version of this ebook in DjVu,

CT PROformance COMBITHERM

If it looks as if it could be in a restaurant kitchen, well,

CT PROformance COMBITHERM

BETTER BUILDINGS BY DESIGN CONFERENCE 2008 Designing a Sustainable Commercial Kitchen FEBRUARY 13 BURLINGTON, VERMONT

CULINARY OPERATIONS September 30, 2010

Kitchenology: Tales of Transformation and Efficient and Effective Operations

CL44eR DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE. Item # Quantity C.S.I.

FT1000e ENERGY RECOVERY STEAM WITH BLOWER DRYER Flight-Type Dishwashing Machine. FT SERIES FT1000e ENERGY RECOVERY STEAM WITH BLOWER DRYER

Middleby Marshall Conveyor Oven, PS 360WB Conveyor Oven Performance Test

COMMERCIAL. Oregon Incentives

Checklists KITCHEN GREENKEYGLOBAL.COM

CL64e DISHWASHER DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE

HIGH-EFFICIENCY EQUIPMENT TECHNICAL SHEET

Technical Report - AM15VL Series Ventless Dishmachines

84 Series 84, 106 PW, 110 FFPW, 120 HDPW High-Temperature Rack Conveyor Dishwashing Machine

Energy Efficiency Business Rebates Product Catalog

COOKING AND HOLDING EQUIPMENT RFP ADDENDUM

CT PROformance COMBITHERM

DIVISION 11 EQUIPMENT. Special equipment shall be designed with the following considerations:

IMPA Energy Efficiency Program

Designed with you in mind. Because every day is Fry Day.

COMMERCIAL FOOD SERVICE KITCHEN EQUIPMENT

LXeR and LXePR HOT AND COLD

Food Service Incentive Application for Business Customers

Absolute Public Auction MULTI-RESTAURANT, BAR, ICE CREAM & CATERING

EN Light And Lighting - Measurement And Presentation Of Photometric Data Of Lamps And Luminaires - Part 1: Measurement And File Format

With Wolf's dual fuel ranges you have state-of-the-art

Base Package (Stainless)

Food Service Incentive Application for Business Customers

With Wolf's dual fuel ranges you have state-of-the-art

This presentation premiered at WaterSmart Innovations 2010 Join us this fall in Las Vegas, October, watersmartinnovations.

Everything you need from an oven

INTELLINOX DEMAND CONTROL KITCHEN VENTILATION

KITCHEN EQUIPMENT'S LEGEND (THE DECK-IHC)- ANNEX -IV

REFRIGERATOR FEATURES AND SPECIFICATIONS

Warehouse Liquidation of Restaurant Equipment Dealer

The Middleby Corporation. Middleby Corporation 2010 Annual Meeting of Shareholders May 4, 2010

With Wolf's dual fuel ranges you have state-of-the-art

Inventory by Lot Number Online Only Auction: November 22 nd 27 th, 2018 For Assets Located In Our Warehouse 1804 Shop Rd., Columbia SC 29201

Transcription:

Page 1 of 5 ENERGY STAR 's qualifying product lists only include products that meet or exceed their current performance specifications. Products that qualified under previous specifications are not listed but still qualify for rebates. Documentation must be provided to show that a product is ENERGY STAR qualified if it isn't listed on their current qualifying product lists. Combination Ovens CODE 2000 Gas Commercial Combination Ovens must have a tested steam mode cooking energy efficiency of 38% or greater and a convection mode cooking energy efficiency of 44% or greater utilizing American Society for Testing and Materials (ASTM) Standard F2861, and meet the idle rate requirements shown in the table below. ASTM F2861 Requirements: Convection Gas Oven Capacity Steam Mode Mode < 15 Pan Capacity < 15,000 Btuh < 8,000 Btuh 15-28 Pan Capacity < 18,000 Btuh < 10,000 Btuh > 28 Pan Capacity < 28,000 Btuh < 16,000 Btuh Qualifying Combination Ovens Company Alto-Shaam (www.alto-shaam.com) Blodgett (www.blodgett.com) Cleveland (www.clevelandrange.com) Electrolux (professional.electroluxusa.com) Eloma (www.eloma.com/us/) Henny Penny (www.hennypenny.com) Lang (www.langworld.com) Piper (www.piperonline.net) Rational (www.rationalusa.com) UNOX (www.unox.com) Number Steam Energy Eff. Convection Combitherm 7.14 ESG 40 49 Combitherm CTC7-20G 52 60 Combitherm CTP10-20G 51 61 Combitherm CTP20-20G 50 59 Combitherm CTP7-20G 47 59 Convotherm BLC*-102G 42 60 BLC*-62G 50 59 C4e* 10.20GS 58 63 C4e* 20.20GB 48 61 C4e* 6.20GB 51 62 C4e* 6.20GS 58 62 OGB-6.20 44 60 OGS-6.20 57 59 OGS-10.20 47 61 OGS-20.20 57 61 Air-O-Convect AOS062GCP1 48 55 Genius T6-11 48 57 T10-11 51 60 FlexiRack FPG115 53 61 ClassicCombi GCC615 44 52 SmartCombi GSC115 46 57 CPE 2.10G 42 60 SelfCooking Center HMG072X 46 54 NAGB071 43 56 A1282* 43 57 A2282* 56 56 A6182* 45 57 A6282* 54 58 SCC102G 45 55 SCC61G 48 51 SCCWE102G 43 57 SCCWE202G 56 56 SCCWE61G 45 57 SCCWE62G 54 58 XAVC-10FS-GPR 49 63 $900 Convection Ovens CODE 2100 per unit = $500 Gas Commercial Convection Ovens must be ENERGY STAR qualified. See qualifying product list for gas convection ovens on the ENERGY STAR website: http://www.energystar.gov/productfinder/product/certified-commercial-ovens/results

Page 2 of 5 Conveyor Ovens CODE 2700 Gas Conveyor Ovens must meet or exceed baking energy efficiency of 42% and have an idle energy rate of 57,000 Btuh or less utilizing American Society for Testing and Materials (ASTM) Standard F1817. Company Edge (www.edgeovens.com) Lincoln (www.lincolnfp.com) Middleby (www.middleby.com) XLT (www.xltovens.com) Number Conveyor Width (Btuh) EDGE60 34" 50% 23,868 Impinger 1600-***-U-K**** 32" 46% 36,393 Impinger with Quest 1600-***-U-K****-AQ 32" 46% 23,402 EMS Impinger 3270-***-N-K**** 32" 44% 53,800 PS570 32" 47% 40,600 WOW PS670 32" 48% 37,465 WOW PS770 32" 48% 37,465 WOW PS870 32" 48% 37,465 3255/3255D 32" 42% 41,700 3240-HP 32" 43% 36,696 Quiet Fire 3855 38" 45% 45,004 3270 32" 47% 42,615 3270-2B 32" 47% 46,017 3870-2B 38" 44% 56,500 $750 Rack Ovens CODE 2200 Gas Commercial Rack Ovens must have a tested baking energy efficiency of 50% or greater utilizing American Society for Testing and Materials (ASTM) Standard F2093. Company Adamatic Corporation (www.adamatic.com) Baxter (www.baxtermfg.com) Doyon (www.doyon.qc.ca) Gemini Bakery (www.geminibe.com) Hobart (www.hobartcorp.com) LBC Bakery Equipment (www.langbakery.com) MIWE (www.miwe.com) Revent (www.revent.se) Sveba-Dahlen (www.sveba-dahlen.se) TMB Baking (www.tmbbaking.com) Number Capacity Adamatic PRO2G Double-Rack 50 Baxter Gemini BXA2G Double-Rack 56 OV500G2 Double-Rack 56 OV500G2-EE Double-Rack 55 Hobart HBA-2G Double-Rack 56 LBC LRO-1G5 Single-Rack 53 LRO-2G Double-Rack 54 LRO-2G4 Double-Rack 52 LRO-2G5 Double-Rack 62 Roll-In e+ 1.0711-TL Double-Rack 52 Revent Dahlen SRO2G Double-Rack 55 V42 Double-Rack 52 724 Double-Rack 58 ONE26 Single-Rack 53 V42 Double-Rack TMB Baking XL2 Double-Rack 53 52 $1,200 Steam Cookers Gas Commercial Steam Cookers must be ENERGY STAR qualified. See qualifying product list for gas steam cookers on the ENERGY STAR website: www.energystar.gov/productfinder/product/certified-commercial-steam-cookers/results Pan Capacity CODE 3 2400 $500 4 2401 $525 5 2402 $550 6 and larger 2403 $575 Griddles CODE 2500 per unit = $175 Gas Commercial Griddles must be ENERGY STAR qualified. See qualifying product list for gas griddles on the ENERGY STAR website: http://www.energystar.gov/productfinder/product/certified-commercial-griddles/results

Page 3 of 5 Gas Infrared Equipment Infrared Equipment CODE Charbroilers 2801 $300 Rotisserie Ovens 2802 $500 Salamander Broilers 2803 $150 Upright Broilers 2804 $600 Fryers 2805 $250 Pasta Cookers CODE 2900 per unit = $200 Fryers Standard Vat Size (Vat Width < 18") - CODE 2300 per unit = $250 Gas Commercial Fryers must be ENERGY STAR qualified. See qualifying product list for gas fryers on the ENERGY STAR website: www.energystar.gov/productfinder/product/certified-commercial-fryers/results Large Vat Size (Vat Width > 18") - CODE 2301 Gas Commercial Fryers must be ENERGY STAR qualified or have a tested heavy load cooking energy efficiency of 50% or greater utilizing American Society for Testing and Materials (ASTM) Standard F2144 for large vat fryers. Company Alto-Shaam (www.alto-shaam.com) Frymaster (www.frymaster.com) Giles (www.gfsequipment.com) Hobart (www.hobartcorp.com) Keating (www.keatingofchicago.com) PBI (www.pbimarketing.com) Pearl City (www.pearlcitymanufacturing.com) Pitco (www.pitco.com) Ultrafryer Systems (www.ultrafryer.com) Vulcan (www.vulcanequipment.com) Number Energy Efficiency Alto Shaam - ASF-75G 71 Frymaster - HD*60G 52 Giles - GGF-720 61 - HK65 66 - HK85 66 - HR65 60 - HR85 60 Keating - 18 IFM 51 PBI - 2600530 52-2600580 52 Pearl City - P-30 71 SGM20 SFSGM20 57 SGMF20 SSH60W SFSSH60W 55 SSHF60W SSH75 SFSSH75 61 SSHF75 SSH75R SFSSH75R 56 SSHF75R VF65 54 Ultrafryer Par 2 F-P20-18 B-P20-18 62 B-P20-20 Ultrafryer Par 2.5 F-P25-18 B-P25-18 59 Ultrafryer Par 3 F-P30-18 B-P30-18 61 Ultrafryer Par 3 B-P30-20 65 Ultrafryer Par 4 P40-18 74 - TR65 60 Vulcan - TR85 60 - VK65 66 - VK85 66 $350

Page 4 of 5 Dishwashers Commercial Dishwashers must be ENERGY STAR -qualified. Your building water heater and the booster water heater (if applicable) must be natural gas to qualify for this rebate. See qualifying product list on the ENERGY STAR website: www.energystar.gov/productfinder/product/certified-commercial-dishwashers/results Dishwasher Type Undercounter Single Tank Door Single Tank Conveyor Multiple Tank Conveyor Sanitation Method Building Water Heater Type Booster Water Heater Type CODE Low Temp Gas NA 2600 High Temp Gas Gas 2601 Low Temp Gas NA 2602 High Temp Gas Gas 2603 High & Low Temp Gas Gas 2604 Low Temp Gas NA 2605 High Temp Gas Gas 2606 High & Low Temp Gas Gas 2607 Low Temp Gas NA 2608 High Temp Gas Gas 2609 High & Low Temp Gas Gas 2610 $300 $600 $800 $1,000 Low-Flow Pre-Rinse Spray Valves CODE 1201 Qualifying Low-Flow Pre-Rinse Spray Valves must have a flow rate of 1.6 gallons per minute or less and a cleanability performance of 26 seconds per plate or less, based on the American Society for Testing and Materials (ASTM) Standard Test Method for Performance of Pre-Rinse Spray Valves. Low-flow spray valve must replace a standard flow unit. Hot water must be provided by a gas water heater. Company Number Tested Flow Rate* BK Resources - PRV-1 0.98 - B064 PRV 0.65 - B074 PRV 0.71 Bricor - B084 PRV 0.84 - B094 PRV 0.91 - B095NS 0.94 Chicago Faucet - 90-LABCP 0.92 - KL50-Y002-16 1.60 Component Hardware - KLP50-Y002-45 0.45 - KLP50-Y002-65 0.67 - KLP50-Y002-74 0.74 - KLP50-Y002105 1.18 Encore - KL50-Y002-12 1.18 - KL50-Y103 0.70 - KL50-Y104 0.70 Ultra-Spray 2949 1.15 Fisher Ultra-Spray 71307 1.15-10197 0.70-13641 0.70 Krowne Metal Water Saver 21-129L 1.19 - M0098SV-065G 0.64 Meisheng - M0098SV-124G 1.20 - M0098SV-142G 1.42 - M0098SV1-124G 1.19 Niagra Conservation - N2180 1.28 - Kwik-Clean 3 0.99 Strahman - Kwik-Clean II 1.16 - Vari-Spray 1.28 - B-0107 1.40 - EB-0107-C 0.64 - B-0107-C 1.24 - Equip 5SV 1.41 T&S Brass - Equip 5SV-C 1.14 - Jetspray B-0108 1.48 50% of Equipment and Installation Cost - Jetspray B-0108-C 1.48 - B-2108 1.38 Zurn - Z80000-PR1 1.23 *Tested by the Food Service Technology Center.

Page 5 of 5 Ventilation Hood Controllers Code 1400 Commercial kitchen exhaust hood control system must be used in conjunction with variable speed fan motor controls. Company Accurex (www.accurex-systems.com) CaptiveAire (www.captiveaire.com) Franke (www.franke.com) Gaylord (www.gaylordventilation.com) Greenheck (www.greenheck.com) Halton Company (www.haltoncompany.com) Intellinox (www.intellinox.com) Melink (www.melinkcorp.com) Spring Air Systems (www.springairsystems.com) Streivor (www.streivor.com) Vari-Flow Energy Management System for Kitchen Hoods VariVent DCV-F DCV-R Vari-Flow M.A.R.V.E.L. ecoazur Intelli-Hood TruFlow DemandAire Variable Frequency Drive Motor Control System * $165/hp (electric) $300 per 1000 CFM (gas) *The Electric is available to electric customers and is calculated using the total nameplate horsepower of the exhaust fans and make-up air fans controlled by the ventilation hood control system. The additional Gas is available to gas customers of Austin Utilities and Owatonna Public Utilities and is calculated using the CFM of the exhaust fans controlled by the ventilation hood control system.