A Study on Problems Arises in Practicing Fire Drill in High Rise Building in Kuala Lumpur

Similar documents
The Development of Fire Risk Assessment Method for Heritage Building

FIRE SAFETY POLICY LEEDS METHODIST MISSION. Oxford Place Centre

Emergency Action Plan

Alternate Evacuation Route B: Secondary direction of egress considered safe with the information available.

Fire evacuation drill

May 27, Mayor Thomas M. Roach Members of the Common Council City of White Plains 255 Main Street White Plains, New York 10601

SCALES NW EMERGENCY ACTION PLAN

May 27, Mayor Joanne D. Yepsen Saratoga Springs Commissioners City of Saratoga Springs 474 Broadway Saratoga Springs, New York 12866

Alternate Evacuation Route B: Secondary direction of egress considered safe with the information available.

Emergency Evacuation Plan South Patterson Building (SPB)

To: All SAAS Accredited Certification Bodies Subject: Clarification to Emergency and Health & Safety Requirements in the SA8000 Standard

Emergency Evacuation Plan. Kettering Labs. School of Engineering

DUNCAN STUDENT CENTER. Emergency Action Plan

Harvard University - OEB Glasshouse Emergency Evacuation Plan

Guideline No 11:2005. European guideline. Recommended Numbers of Fire Protection Trained Staff

FIRE PROTECTION PROGRAM

TABLE OF CONTENTS Part 6 Legal Basis for Fire Safety Planning... 2

Evacuation and Lockdown Plan

Table of Contents CHAPTER 10 ADMINISTRATIVE RULES FOR CERTIFICATION OF CHILD CARE FACILITIES FIRE STANDARDS FOR FAMILY CHILD CARE HOME

Project: Location: Date Prepared: Last Reviewed:

RAMBLER PARK FIRE SAFETY INFORMATION

GUIDELINES FOR EMERGENCY PLANNING AND PREPAREDNESS. High-Hazard

Ref : NTU/OHS/SOP/06.2 Date of issue : 24 July Updated by : Wong Zhi Hao Next review date : 23 July 2014

FIRE SAFETY POLICY Revised March 2013

TG FIRE DRILLS. Office of the Fire Marshal and Emergency Management

NOTTINGHAM CITY HOMES

[Name/title] is the Alternate Safety Officer/ Alternate Emergency Coordinator.

Emergency Planning and Preparedness

Universiti Tunku Abdul Rahman STANDARD OPERATING PROCEDURES

Emergency Evacuation Plans and Exercises. Risk Management Services

Preparedness Committee Security and Life Safety Commercial Office Building Protective Measures

Emergency Action Plans (OSHA ) Abstract. Introduction. Emergency Action Plan (EAP) Elements of an EAP

Emergency Evacuation Plan and Implementation Guidelines The Pennsylvania State University

Use this guide to assist you when completing the Evacuation scheme application form.

Fire Safety Policy 29/09/2017. Holme Grange School Whole School Policy Including EYFS. Fire Safety Policy

St Edward s Oxford FIRE SAFETY POLICY

EMERGENCY PROCEDURES

EMERGENCY PREPAREDNESS & RESPONSE PROCEDURE

Property Name & Address [ Property Name ] - [ Property Address ]

Passive fire building protection system evaluation (case study: millennium ict centre)

RESEARCH ON THE MAIN CRITERIA OF DECISION-MAKING FACTORS THAT AFFECT CONSUMERS' PURCHASE OF RESIDENTIAL FIRE ALARMS

FIRE SAFETY POLICY. Approval Approved by: University Court Date: March 28 th 2017

Department of Physics/Block S11/Science Faculty NATIONAL UNIVERSITY OF SINGAPORE 2 ACTIONS TO BE TAKEN IN THE EVENT OF FIRE DURING OFFICE HOURS

Fire Evacuation Manual

Cedar Hammock Fire Rescue Standard Operational Guidelines FIRE WATCH. General. Requirements for a Fire Watch

Fire Safety Strategy

Emergency Evacuation Plan and Implementation Guidelines The Pennsylvania State University BLUE BAND BUILDING ( )

NHS Tayside. Fire Safety Policy

What is an Emergency?

Department of Biological Sciences National University of Singapore. 4. Procedures: ACTIONS TO BE TAKEN IN THE EVENT OF FIRE DURING OFFICE HOURS

911 Consulting. New York City Emergency Action Plans 18 Obligations of Tenant/Employers in High Rises

Thomasville fire rescue

Computer Simulation Investigation on the Effect of Channelled and Unchannelled Screens on Smoke Contamination in Atriums Upper Balconies

FIRE EVACUATION PLAN PRATT STREET PARKING GARAGE AND ATHLETIC CENTER POLICE FIRE MEDICAL EMERGENCY

2015 DEPARTMENT OF STANDARDS MALAYSIA

Health and Safety Policy. Version Author Revisions Made Date 1 Colin Campbell First Draft March 2014

ADMINISTRATIVE SERVICE/DEPARTMENTAL Emergency Response Plan (EPR) This Emergency Plan is written for occupants of the following work site.

Non-Emergency Direct Line Telephone Numbers. Emergency Direct Line Telephone Numbers

FACILITY OF EMERGENCY PLAN. (Template)

SIOUX FALLS FIRE RESCUE STRATEGIC PLAN

FIRE SAFETY AND EVACUATION PLANNING FOR ASSISTED LIVING FACILITIES AND NURSING HOMES

Arbour House. Fire Policy and Procedures

"EVACUATION PROCEDURES"

University of Maryland FIRE EVACUATION PLAN Columbus Center POLICE FIRE MEDICAL EMERGENCY - 911

Patrick County Horizons Jeb Stuart Hwy. Stuart, Va

MOIEZ AHMED Chief Fire Warden Director Training - Usha Armour Pvt. Ltd., Bangalore. Fire Drill (Fire Evacuation Drill Procedure)

Floor Warden Training

Management Standard: Fire Safety

HAZARDOUS MATERIALS/WASTE EMERGENCY CONTINGENCY PLAN University of Southern Maine Portland Campus

Emergency Evacuation Plan and Implementation Guidelines The Pennsylvania State University

Fire Evacuation Plan

EVALUATION OF EVACUATION AT FACULTY ENGINEERING

ABSTRACT. State adoption is not required, See Paragraph V. Directorate of Compliance Programs. 200 Constitution Avenue, NW Washington, DC 20210

School EMERGENCY PLAN

DEF Fire Evacuation and Emergency Planning Criteria

IRVING FIRE DEPARTMENT EMERGENCY PLANS

November Safety Subject

BUILDING EMERGENCY ACTION PLAN. for Your Building Name

FIRE AND EMERGENCY EVACUATION PROCEDURES STARCROSS PRIMARY SCHOOL

Title: BCCK Evacuation Procedures

FIRE EMERGENCY PLAN PHYSICS BUILDING

FIRE SAFETY POLICY. This policy refers to both Wellington Senior School and Wellington Prep School

CITY OF HOUSTON HIGH-RISE OFFICE BUILDING FIRE SAFETY PLAN

June 2017 (Updated 18 January 2018) Fire Safety Policy. Peter Webb, Project Manager Compliance First Choice Homes Oldham Limited

TEN STEP PROCESS PREPARING FIRE SAFETY PLANS

2012 SunTrust Center ERT Annual Review. 919 East Main St. Richmond, VA

STATEMENT OF THE HEALTH AND SAFETY STRATEGY FOR THE SYDNEY RUSSELL SCHOOL

ICC CODE CORNER 2015 International Fire Code

Leader s Guide Marcom Group Ltd.

HEALTH, ENVIRONMENT AND SAFETY MANAGEMENT FOR FACILITIES MANAGERS COURSE OUTLINE

Division of Public Health Administrative Manual

Firefighting operations on multi-tiered vehicle stacking buildings F5-13 GD

Emergency Action Plan

FIRE PREVENTION AND PROTECTION*

Bold items are particular to the City of Euless

Terminal & Building Emergency Evacuation Induction

Fire Safety Policy. Investing in success. Dukes Centre Dukes Avenue Kingston KT2 5QY 1. Policy

FIRE SAFETY PLAN FIRST & JASPER JASPER AVENUE

HAZARDOUS MATERIALS/WASTE EMERGENCY CONTINGENCY PLAN University of Southern Maine Portland Campus

UNCONTROLLED IF PRINTED. Issued with the authority of the Chief Commissioner and General Manager of Scouts Australia NSW

Transcription:

E3S Web of Conferences 3, 01017 (2014) DOI: 10.1051/ e 3sconf/20140301017 C Owned by the authors, published by EDP Sciences, 2014 A Study on Problems Arises in Practicing Fire Drill in High Rise Building in Kuala Lumpur N.F. Zahari 1, A.F. Alimin 2, M.D. Sudirman 3, M.A.O Mydin 4 1,2,3 Universiti Teknologi MARA, Perak, Seri Iskandar, Malaysia 4 School of Housing, Building and Planning, Universiti Sains Malaysia, 11800, Penang, Malaysia Abstract. Fire drill is one of the steps taken to mitigate the risk trapped in a building during outbreak of fire. Hence, it is very important for every building to practice fire drill, especially high-rise building. Referring to Fire and Rescue Department of Malaysia (BOMBA), high-rise building had a higher risk compared to other type of buildings. However, there might be problems arise to practice fire drill especially in high-rise building. This research intends to study on fire drill procedure and identify any possible common problems arises when practicing fire drill in high-rise building in Kuala Lumpur. Information was gained through regulations and guidelines associated with fire drill procedure and also parties involved in the practice. Besides, a survey is done for awareness of occupants in high-rise building on fire drill practice. For the case study, three high-rise building are selected in Kuala Lumpur based on specific criteria. Analysis for this research comprises of comparative and descriptive approach as well as statistical analysis which are documented based on case studies and questionnaire survey. The findings indicates that there is no standardized procedure in fire drill, while the most common problems that can be seen in practicing fire drill are lack of commitment among occupants, lack of information on fire drill and output on weaknesses after fire drill been practiced. 1 Introduction Fire is a hazardous and life threatening towards living things. Although it said that not all fire resulting in death but the effect came from outbreak of fire are rather alarming. It is further worsen, if fire occurred in the building which fully occupied by the human being. Hence, it will absolutely cause an enormous loss of property and in extreme cases the fire can lead to progressive building and structural collapse. Hence, fire drill is one of the steps that can mitigate the risk being trapped in a building during outbreak of fire. Fire drill is a method of practicing the evacuation of a building for a fire or other emergency. Generally, the fire drill serve as an oppurtunity for the occupant to demonstrate, under simulated fire conditions, that they can perform evacuation safely and ensure they are aware enough of that responsibilities. Body that is responsible and involved in doing and supervising fire drill is Fire and Rescue Department Malaysia (BOMBA) while regulations and guidelines associated in fire drill are Uniform Building By-Law (UBBL) 1984 [1], National Fire Protection Association (NFPA) Codes and Standards [2], Fire Services Act 1988 and Hazardous Material (HAZMAT) code and also Occupational Safety and Health (OSHA) 1994 [3]. This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Article available at http://www.e3s-conferences.org or http://dx.doi.org/10.1051/e3sconf/20140301017

E3S Web of Conferences 2 Literature Review In Oxford and Collin Dictionary, fire drill is defined as practice of emergency procedures to be used in case of fire and a rehearsal of duties or escape procedures to be followed in case of fire. Highrise building is defined in NFPA 101, Life Safety Code, 2012 Edition as a building more than 75 feet or 23 meters in height, measured from the lowest level of fire department vehicle access to the floor of the highest occupiable story. In addition, high-rise building usually consist of mix tenancy which cater for office premises, malls, retails, hotels and others. Indirectly, the population of occupant is enormous and might reach to several thousand at a time [4]. The risk of fire for high rise building is quite high rather than the landed buildings, the multiple floors of a high-rise building create a cumulative effect of requiring great numbers of person to travel great vertical distances on stairs in order to evacuate the building. The risk of fire is commonly recognised as a serious threat to the life safety of occupants in the buildings. History has repetedly demonstrated how hazardous and catastrophic impact of fires can have on buildings and their occupants [5]. Basically, when arranging fire drill, the employers or the building manager set up the date with the nearest Fire Department to conduct a good fire drill. Once the date have been set up, the building manager or the building department will inform to the head of floor in each floor about the fire drill and it will be spread out through all the occupants in that premises. Fire drills may be pre-announced to building staff or occupants, or they may be unannounced. As noted in Section 2.8 of the Fire Code, the chief fire official must be consulted on the development of fire drill procedures. The procedures for conducting fire drills must be included in the fire safety plan. When developing the fire drill procedures, consider the following factors to ensure the fire drills are relevant: a) the building use and associated fire hazards; b) the safety features provided in the building; c) the desirable degree of participation of occupants other than supervisory staff; d) the number and degree of experience of participating supervisory staff e) the testing and operation of the emergency systems installed in buildings within the scope The main objective of this research is to study the procedure of fire drill in any regulations in Malaysia. Second objective is to identify the most common problems that arise in practicing fire drill in high rise building in Kuala Lumpur. Third objective is to determine the awareness among building occupants towards the importance of fire drill and knowledge on the fire safety in their workplace. 3 Methodology The research methodologies consist of a serial chronological process that requires a step-by-step approach; specifically designed in order to achieve the research objectives with the main concern of studying procedure of fire drill in any regulations in Malaysia, identifying common problems arise in practicing fire drill in high-rise building and awareness among building occupants towards the importance of fire drill and knowledge on the fire safety in their workplace. The method of identification and examination is based on analyses of questionnaires, personal interview and observation through those three case studies. Appropriate methodologies are designed specifically to ensure achievement of objectives. 01017-p.2

Emerging Technology for Sustainable Development Congress (ETSDC 2014) Determination of objectives and scope of works Literature review conducted Field research conducted based on case study Primary sources (semi structured interview, questionnaire) Secondary sources (literature review, books, journal, articles etc ) Data analyzed Findings 4 Case Study 4.1 Introduction Conclusion and recommendation Figure 1: Research Methodology Flow The case study was conducted in three locations which are TH Selborn Tower (Figure 2), PJD Tower (Figure 4) and Celcom Tower (Figure 5) where all three towers are located in Kuala Lumpur. Selection of building is based on average height between 20 to 30 floors. All three buildings practices fire drill conducted and supervised by nearby Fire and Rescue Department. Based on the criteria required, these buildings are suitable in order to be selected as the case studies. Figure 2: TH Selborn Tower, Kuala Lumpur. 01017-p.3

E3S Web of Conferences 4.2 TH Selborn Tower, Kuala Lumpur This building was completed in 2001 fully owned by the LembagaTabung Haji as one their office buildings in Malaysia. This building is located at 153, JalanTunRazak, Kuala Lumpur at the junction of JalanSemarak and JalanTunRazak. MenaraSelborn is a 31 storey building with 4 level of basement parking and 1 level of service floor and 26 floor of office space and also mezzanine floor. There are few tenants that rent in the TH Selborn such as Malaysian Airforce, Bank SimpananNasional, Perpustakaan Negara and other companies. Figure 3: Emergency Response Team (ERT) Organization Chart in TH Selborn. There are 6 basic roles that responsible in the aspect of prevention, fire control and rescue the occupants in the building before the arrival of Bomba. The Building Manager act as an Emergency Manager and Time Keeper is the one who keep the records and take down all the details of fire drill and emergency for future records saving. LembagaTabung Haji has its own Safety Officer that manages all of their buildings in order to protect and control in terms of safety among their staff and tenants. Property Management Department responsible in ensuring their buildings are in good conditions and safe to occupy. Fire drill has been practiced once a year in this building (Figure 3). 4.3 PJD Tower, Kuala Lumpur With 28 storey high, this commercial and office tower consisting of 5 floors of commercial podium and 8 floors of car park located at Jalan Tun Razak, Kuala Lumpur was completed in year 2010. Near to the Titiwangsa LRT Putra and monorail. This building is owned by the PJ Developer Holdings Berhad and the anchor tenant for this building is JKR- Cawangan Kerja Bangunan Am. The management for this building is PJD itself. For mean of fire risk and hazard for this building, there is no specific organisation chart that control or manage the fire drill. The fire drill had been practiced once a year in this building. Figure 4: PJD Tower, Kuala Lumpur. 01017-p.4

Emerging Technology for Sustainable Development Congress (ETSDC 2014) 4.4 Celcom Tower, Kuala Lumpur This Celcom building is 22 stories high with basement parking, office space and commercial space where it has been Celcom Axiata Berhad Kuala Lumpur headquarters since 2002. This building was formerly known as Wisma Telekom JalanSemarak and is next to Marinara Tower (Menara 238) and opposite to the Wisma Perkeso. The fire drill has been practiced twice a year in this building with the supervision of Balai Bomba Hang Tuah and Balai Bomba Maharajalela. However, there is no specific organization or team act as ERT. 5 Finding Analysis Figure 5: Celcom Tower, Kuala Lumpur Analysis of this research is divided into three sections where each section achieving the objectives stated earlier. Critical analyses are done on the regulations, standards and codes that associated with fire drill while personal interview is done to find out the common problem when practicing fire drill and questionnaire is done to see the awareness level among building occupants. 5.1 Analysis on Regulations, Standards and Codes There are a few fire regulations that implemented in Malaysia by the Bomba such as Uniform Building By-Law (UBBL) 1984, National Fire Protection Association (NFPA) codes and standards, Fire Services Act 1988, and also from Occupational Safety and Health (OSHA) 1994. Generally, these codes and standards are used as the reference regarding the fire for buildings. However, there are no standard procedure of fire drill stated in these regulations, standards and codes and this finding analysis is supported by three officers of Fire Department in Putrajaya, Kuala Lumpur and Ipoh. However, they provide the standard of operation prepared by them as below: i. The building owner or the building manager prepare an intent letter and send it out to Bomba fo rasking them to monitor or handle the fire dill ii. letter received. Bomba reply the letter of acceptance for joining and monitoring the fire drill. iii. then,building manager set up the date and time and all the details for the firedrill exercise. send againto the Bomba to inform them iv. Bomba received that letter and set up the date for the coming fire drill v. Before that day, Bomba having a simple briefing to the Emergency Response Tean (ERT) and staff about the fire drill. vi. On that day, fire alarm rang in that premises. Gathered all the occupants in assembly point. Time keeper records all the details happend. 01017-p.5

E3S Web of Conferences vii. Each floor warden check up on their staff by head counting, then report to the responsible personnel. viii. Briefing by the Bomba personnel regarding the programs and demonstrated the emergency and rescue the victims and also the right way to use a firefighting aid such as fire extinguisher. ix. Post mortem meeting among the management team and Bomba regarding to the fire drill and the analysis as the report and reference in the future. 5.2 Analysis on Personal Interview Semi structured interview is adopted in this research. The purpose of the interview is to get more information and achieving the second objective of this research. The semi structured interview only conducted to selected person from the Building Management Department of the case studies. The question in this interview was in open ended question. Table 1: Analysis on the common problems of fire drill. Question: What are the common problems arises in executing fire drill in this building? Respondent 1 1. Lack of commitment among occupants. 2. The floor warden and ERT did not perform his/her role appropriately 3. Lack of information and output after the fire drill be given to the occupants Respondent 2 1. Poor planning by the management 2. Absence of occupants during fire drill exercise. 3. Lack of information and output after the fire drill be given to the occupants Respondent 3 1. Absence of Pelan Tindakan Kecemasan by the managemen 2. Lack of commitment by the occupants. 3. Lack of information and output after the fire drill be given to the occupants The respondents stated that the common problems are lack of commitment among occupants during fire drill, the floor warden and emergency response team (ERT) members did not execute their role properly due to insufficient information and training before the fire drill carried out. Then, the most common problems for the three surveyed site is lack of information and output after the fire drill or postmortem are not given to the occupants as they need to know what the weaknesses that need to be improve. Then, the poor planning by the management also been highlighted in the interview, as the respondent said, the management team did not properly plan the fire drill and what should be stress on that day to give an optimum information and awareness to the occupants. 5.3 Analysis on Questionnaire The design of the questionnaire comprised with three (3) section which is part A, part B and part C. Part A focused on the demographic data. Parts B are questions in Likert-scale which is on knowledge of fire safety in workplace. Meanwhile Section C is about the awareness on the importance of fire drill. Table 2: The awareness and knowledge on the fire safety at workplace. Score Frequency (person) Percentage (%) Strongly Disagree Disagree Not Sure Agree Strongly Agree 4 35 193 227 3 0.9 7.6 41.8 49.1 0.6 Total 462 100.0 Most of the respondents, 49.1 percent of them were agreed on this statement that they really know and aware of fire safety at their workplace. However, only 0.9 percent of respondents did not know 01017-p.6

Emerging Technology for Sustainable Development Congress (ETSDC 2014) and aware of the issues given and 41.8 percent were not sure whether they agree or not towards the statement given. Based on the result above, majority of the respondents know and aware on the fire safety because of the proper installation,signage and information of fire safety being exposed to them as the occupants. 6 Implication of Research This research intends to contribute to a significant practice of fire drill and increase the awareness of fire safety among building occupants. Besides, through findings of common problems found in practicing fire drill, this research hopes for all parties to be aware and solving the problems together. This study however only limited to the use of self- reported measures that may affect the responses by intentional distortions and misinformation. 7 Conclusion Through this research, it is found that there is no standard procedure of fire drill even though there are regulations, standards and codes and this could lead to many different procedure among states or worst among Fire and Rescue Department. Moreover, every party should play their role in order to ensure a good practice of fire drill is implemented. However, awareness and knowledge of fire safety is at an average level which indicates that there must be a strategy to be implemented in order to increase the awareness and knowledge. References 1. UBBL (Uniform Building by-law).(2003), International Law Book Services, Malaysia. 2. NFPA (National Fire Protection Associations).List of NFPA fire codes and standards 3. OSHA (Occupational Safety and Heatlh) Act 1994.Regulations and Orders.(2011). International Law Book Services. Malaysia. 4. Jerry, L.B (2001). Employee Fire and Life Safety: Developing a Preparedness Plan and Conducting Emergency Evacuation Drills.Introduction to Employee Fire and Life Safety, edited by Guy Colonna, 2001 National Fire Protection Association (NFPA). 5. Mohammad A.H (2009) "On the challenges of evacuation and rescue operations in high-rise buildings", Structural Survey, 27(2):109 118 01017-p.7