Similar documents
Air-Cooling Evaporators

Energy efficient vacuum freezing ice slurry generation using a R718 compressor

Advanced heat transfer technology

Chilled Water system

HVAC - Central System Thermal Storage

Tetra Pak Rotary Moulder 35 A2 Moulded stick novelty freezer

Tetra Pak Rotary Moulder 35 A2 Moulded stick novelty freezer

Midwest Industrial Initiative Webinar: Industrial Refrigeration

Evaporators. Direct Expansion Flooded Recirculated Over Feed

Milk cooling systems

03-08 Individually Quick Freezer Conveyor ( IQF ) Horizontal Contact Freezer Air Blast Freezer ( Cabinet & Tunnel type )

PowerPoint Presentation by: Associated Technical Authors. Publisher The Goodheart-Willcox Company, Inc. Tinley Park, Illinois

Turbo Chiller Now in Stock "Click Here" for details. (1 of 2)8/12/ :01:18 AM

Product Guide Advanced solutions & better usage of raw material

CHP-turbine room. CHP can capture almost EXTRACTED STEAM 20 PSI HIGH-PRESSURE STEAM 1250 PSI HEAT EXCHANGER HOT WATER SUPPLY F

Evaporation System: Types and Design Aspects

Levels of Production

Ammonia Refrigeration & Scenario in Industrial Refrigeration. By Ramesh Paranjpey ASHRAE Fellow Life member

30GN FLOTRONIC II AIR-COOLED CHILLERS

2How does a vibratory fluid-bed dryer work?

The cold chain in the fishery sector. Refrigeration Technology Review

30GT FLOTRONIC AIR-COOLED CHILLERS

Choose the winning team. Heat transfer technology for industrial cooling and air conditioning

HEAT EXCHANGERS Maximize Thermal Efficiency with LaZerWeld Plate Heat Exchangers. For Industrial Refrigeration

The Evolution of the Brewery Chiller System. A 20 year retrospective

Packaged Ammonia Chillers with Variable Frequency Drives powerpac

Polaris PHEs vs. Shell-and-Tube Exchangers

BRINE CIRCULATED ICE THERMAL STORAGE SYSTEM DESIGN - CASE ILLUSTRATION - Partial Ice Storage for Air Conditioning Application

TMCI Padovan Evaporators

AlfaNova the first fusion-bonded plate heat exchanger. A product brochure for AlfaNova within Industrial Refrigeration

ICE THERMAL STORAGE SYSTEM USING DYNAMIC ICE IN HERBIS OSAKA PHASE I AND II PROJECTS

BASE LEVEL AUDIT REQUIREMENTS REFRIGERATION SYSTEMS 1. SITE DATA COLLECTION. Business Name. Site physical address (Street, Suburb, City)

Energy consumption storage facilities examined in ICE-E

GUCHEN THERMO TRANSPORT REFRIGERATION UNITS INTRODUCTION

Concrete Cooling Systems

Hot Water Heating Systems

AC SYSTEM CONFIGURATION- CENTRAL CHILLER PLANT

A New Dimension in Refrigeration

Building air conditioning systems using Ice-Cel thermal storage can be designed which cost little or no more than conventional chiller-only systems.

THERMAL ICE STORAGE: Application & Design Guide

Freeze Drying. RAY plants for the food and beverage industries

Calhoon MEBA Engineering School. Study Guide for Proficiency Testing Refrigeration

CO 2 Ice Bank Answer to the next requirements

Refrigeration. Value and Dependability

Small Commercial Business Energy Audits. Recognizing and addressing the special requirements of the small business market segment.

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

A Cover ENERGY EFFICIENT

Partial Load Performance Of Refrigeration System

PPL Electric Utilities Energy Efficiency and Conservation Program

ParaWeld Plate Heat Exchangers

Refrigeration Systems

quick start guide Product features RF266 RF263 RF267 RF26X Twin Cooling System Easy Handle Secure Auto Close

Heat Exchanger. The purpose may be either to remove heat from a fluid or to add heat to a fluid.

Refrigeration. Bosch pioneers in design and energy conservation to produce a range of innovative refrigeration products to suit every need.

Carnot. 2. (a) Discuss the advantages of the dense air refrigeration system over an open air refrigeration system?

Refrigeration (Kylteknik) 8. Heat pumps, heat pipes, cold thermal energy storage

Advanced heat transfer technology. Thermo plate products for the process industry. Substantial energy savings through customized designs

AIR COOLERS CONDENSERS DRY COOLERS SPECIAL PRODUCTS

the ultimate drying technology

Parilla Thermal Storage Project Case Study. May Page 1 of 11

Heat Pump Assisted Drying - Freeze Drying Technology

Chapter-8 Capacity Control of Refrigeration Systems

Drying rate 1. Section B to C of the curve, known as the constant rate periods, represents removal of unbound water from the product.

quick start guide Product features RF195/197** RF215/217** Moving Tray Surround Multi Flow Twin Cooling System Digital Display & Temperature Control

MAJA solutions for the food trade

Korean Side-by-Side Refrigerator Use and Care Manual

ParaWeld Plate Heat Exchangers

MECHANICAL ENGINEERING ME.2017 FUNDAMENTAL OF REFRIGERATION AND AIR CONDITIONING. Sample Questions and Answers

Installation & Operations Manual for. MSC-A & MSF-A Model. Display Freezers. 5/16 Rev. A

Nature can make it I N N O VAT O R S I N R E F R I G E R AT I O N A N D C O O L I N G T E C H N O L O G I E S

Combi-Line. Requirement-orientated solutions for ice cubes and crushed ice

FACT SHEET 6 Transport Refrigeration

User manual. Fridge Freezer ZRT18100WA

Commercial Refrigeration

Technical Review. Remote Condenser Cuber. Enhanced Refrigeration and Water Systems. CM 3 Technology. of a. with. using. models included are:

MECHANICAL SERVICES 101. Ian White

Plate heat exchangers for refrigeration. Product catalogue for semi-welded and all-welded plate heat exchangers

quick start guide Product features RF195/197** RF215/217** Moving Tray Surround Multi Flow Twin Cooling System Digital Display & Temperature Control

13:00 h REAL FRESHNESS

PICEM75 Ice Maker & Dispenser

FALLING FILM CHILLERS


Tetra Pak Linear Moulder 1500 A2 For high capacity production of moulded stick products

HRV-IP. Ceiling Type Heat Pump Heat Recovery Unit

SPECIALIZED EQUIPMENT

Figure 22-1 Evaporator sensible and latent capacity vs. entering air wet bulb

(Refer Slide Time: 00:00:53 min)

EN aquatech.piovan.com

Vogt Tube - Ice machines P34AL

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd

Technological developments in aquaculture, fishing technology and processing

Power-to-Cold using vacuum ice slurry technology in the scope of German WindNODE project

Exhibition Hall 1. Fachprogramm. Technical Programme

General Guidance. The easiest way to establish the amount of refrigerant in the system is to use data supplied by the manufacturer:

AIFe. Ice Cream Machiner y

Customers. The core of our innovation. Feeding&Conveying Drying Dosing Temperature Control Refrigeration. Granulation

OGA / OGV Nordbaden eg Bruchsal relies on Güntner cooling components

Green economy with natural refrigerants

Blast Freezers and Chillers for Ice Cream Parlors, Confectioners, Bakeries, Delicatessens and Restaurants

New standard in compressed air treatment, providing Energy Savings up to 99%

Transcription:

Falling Film Chiller BUCOdelot water down to 0,5 C Application fields Industrial chilling of food fish, meet, poultryl fruit, vegetables milk, milk products softdrink production production of baked goods Chilling in the production of concrete chemicals pharmaceuticals Evaporator system for heat pumps at lowest water temperatures

Reliability In the BUCOdelot or baudelot cooler the homogeneous falling film allows to chill water down to 0,5 C without danger of freezing. The unit will not even be damaged, if the regulation fails and causes the building of ice. The Falling film chiller allows the operation with polluted liquids as well. Application and benefit Water chilling down to 0,5 C Chilling of products down to near the freezing point, without danger of freezing it! Specifications Cooling power from 10 to 10.000 kw Evaporator for all refrigerants, gravity-, pump-, and dx-mode, or for brine Stainless steel completely PIC left to right BUCOdelot compact system with tank, power 100 kw - dx; BUCOdelot typ A, power 1000 kw; BUCOdelot typ B, power 2000 kw Design and Dimensions Examples for typical measurements, without tank Compact - system System typ A System typ B ( ca. measurments in m ) L 1,2 2,0 3,8 W 0,5 2,1 H 1,8 2,0 2,0 Accessibility open distribution tray, big drain to remove particle: removeable side covers, open panel system

Method of operation Water is pumped into the distribution tray and at a controlled rate is distributed homogeneously by a distribution through onto vertical panels in an open system. There the high flow velocity ensures highly efficient heat transfer with a self cleaning effect, which allows the operation with polluted liquids as well. In the BUCOdelot or baudelot cooler the homogeneous falling film allows to chill water down to 0,5 C without danger of freezing. The unit will not even be damaged, if the regulation fails and causes the building of ice. Advantages water down to 0,5 C without danger of freezing reliability for polluted liquids like grey water as well low affinity for soiling open design no gaskets easy to clean stainless steel completely, for salt water as well durability low refrigerant content individual design if required BUCOdelot Falling Film Chillers for more than 30 years More than 1500 BUCOdelot in operation Heat Transfer Technology AG Bernastrasse 6, 3005 Bern, Switzerland Telephone: +41 (0) 3131024-01 sales@htt-ag.com Telefax: +41 (0) 3131024-15 www.htt-ag.com

Industrial Ice Bank Cooler System - BUCO Ice Bank lowest refrigerant content Application fields Industrial chilling with peak loads Production of food Dairies Breweries Production of soft drinks Chilling in the production of Chemicals Pharmaceuticals

Efficiency The benefit of an ice storage unit is the increased cooling power for peak loads while using smaller refrigeration machines, which have to be designed for the average demand only. The cost efficiency is based on the utilization of low night tariffs, which sometimes cost half the money, or on limiting the max electricity peaks, which reduces the basic price of electricity. Application and benefit Storage of refrigeration capacity in ice Increasing of peak cooling power with smaller refrigeration machine Limiting peaks in electricity consumption Advantage of using low night tariffs for electricity Specification Storage capacity from 50 kwh to 2000 kwh Evaporator for all refrigerants and modes or for brine Stainless steel completely Ready to plug or for local refrigeration units Design and Dimensions Examples for typical measurements Compact - system System typ A System typ B ( ca. measurments in m ) L 0,5 10 W 2,3 2,3 2,3 H 1,5 2,2 2,2 PIC left to right Air agitation to provide turbulence; BUCO Ice Bank compact unit, 600 kwh; Stainless steel evaporator panels - low refrigerant volume (about 40% compared to a coil system with pipes). BUCO Ice Banks for more than 50 years. More than 1000 BUCO Ice Banks in operation

Method of operation Storage or building ice: Evaporator panels are placed upright in a rectangular water tank. Ice is build at an evaporation temperature between -4 and -10 C, depending on the storage time. The ice sticks to the evaporator panels. (static ice bank) For ammonia systems, a separate suction pipe at the evaporator ensures the oil return. Cooling phase or thawing phase: On the tank floor there is a distribution system for the warmer return water to ensure a homogeneous thawing of the ice. Additionally there is a distribution system for the air agitation, which provides intensive turbulence to ensure a perfect heat transfer and low ice water temperatures. The air agitation starts up automatically when required only. A maximum of cooling power is ensured at lowest ice water temperatures due to a nearly constant ice surface up to the very end of the cooling phase. Advantages very stable ice water temperature below 1 C up to the end of the process very high cooling power for peaks stainless steel completely low refrigerant content open design easy inspection, easy cleaning compact design as a package for truck transport use of existing tanks possible Heat Transfer Technology AG Bernastrasse 6, 3005 Bern, Switzerland Telephone: +41 (0) 3131024-01 sales@htt-ag.com Telefax: +41 (0) 3131024-15 www.htt-ag.com

Ice Bank Silo Ice Storage Unit with Ice Maker extra high cooling pow er Application fields Industrial chilling with peak loads Production of food Dairies Breweries Production of soft drinks Chilling in the production of Chemicals Pharmaceuticals

Efficiency of making ice The efficiency of the dynamic ice making with hot gas melting is based on the prevention of a thick ice shell on the evaporator, which causes a big resistance for heat conductivity at static systems with a thick ice layer. Efficiency of direct chilling The evaporator can be free of ice at any time after thawing and therefore can be used as a direct chiller for the warm return water. Direct chilling on the iceless evaporator allows a much higher evaporation temperature, a higher COP of the refrigerant compressor and thus less electri city costs. The direct chilling is recommended to be used as long as possible for the ground load. The mode can be switched automatically as a function of the return water temperature. Application and benefit Storage of refrigeration capacity with crushed ice Increasing of top peak cooling power with smaller refrigeration machine Reduction of peaks in electricity consumption Additional use as direct chiller to allow lower energy costs. Design and Dimensions typical measurements for the evaporator Compact - system System type BEE (ca. measurments in m) L 2,0 2,0 W 1,0 3,0 Silos D H ca. 4,0 12,0 up to ca. 4,0 20,0 H PIC left ice silos with 5000 kwh storage capacity each Pic right ice maker for 6 to/h. At 10 h buildup time 5600 kwh Specification Storage capacity from 2.000 kwh to more than 10.000 kwh Stainless steel completely Evaporator for all refrigerants, pump- or dxmode

Method of operation Making Ice Ice is frozen on vertical evaporator panels and forms a 6 8 mm thin layer of ice, which keeps the resistance of heat conductivity always at a low level. After some minutes of building up ice, an automatic plc system will give a signal for hot gas injection to the heat exchange panel for some seconds in order to split off the ice. Afterwards the evaporator is free again to form ice in an efficient thin layer. Advantages stainless steel completely durability reliability low refrigerant content extra high cooling power for peaks efficiency through option of direct chilling very stable ice water temperature below 1 C open design easy inspection, the system is not under water nearly any tank geometry possible use of old existing tanks possible silos require minimum ground space BUCOdelot Falling Film ice making and storage for more than 20 years. More than 200 BUCOdelot ice makers in operation Heat Transfer Technology AG Bernastrasse 6, 3005 Bern, Switzerland Telephone: +41 (0) 3131024-01 sales@htt-ag.com Telefax: +41 (0) 3131024-15 www.htt-ag.com

Industrial Ice Maker for Chip Ice - BUCO Ice Pack Making ice for half the price! Application fields Industrial chilling with peak loads Production of food, Dairies, Breweries, Production of soft drinks Chilling in the production of Concrete Chemicals Pharmaceuticals

Efficiency The efficiency of the dynamic ice making is based on the big evaporator surface, which allows much more efficient evaporation temperatures compared to other systems that use small evaporator drums and mechanical scraper. Drum systems work with evaporation temperatures between -20 C and -30 C. The BUCO-Ice Pack works between -8 and -10 C. That saves energy for electrical drives and allows to make ice for about half the price. Example: 30 to ice/day, Price for electricity: 0,15 /kwh el Running costs at -30 C - Drum system 324 /day or 11 / to ice Running costs at -10 C BUCO Ice Pack: 173 /day or 6 / to ice Savings: 151 / day For 300 days production: 45.300,- / year savings of electricity costs! Ice harvesting When the ice falls from the evaporator, it breaks to pieces which pass a separator for water. Afterwards the ice is crushed to small pieces by using a rotating ice crusher: The crushed ice falls downwards below the ice maker on the whole length of the system and is ready for transport to any industrial process via conveyor belt or a screw conveyor. The exit height may be adjusted by a scaffold. The size of the ice pieces and the ice thickness can be preadjusted steplessly. Making Ice Ice is frozen on vertical evaporator panels and forms a thin layer of ice, which keeps the resistance of heat conductivity always at a low level. Normally the ice thick is 6 8 mm, but it can be adjusted steplessly from 3 to 15 mm depen ding on the application. After some minutes of building up ice, an automatic plc system will give a signal for hot gas injection for some seconds in order to split off the ice. Application and benefit Consumable ice for direct cooling of products Increasing of cooling effect by direct contact with ice Specification Chip ice, not subcooled, no sharp edges 10 bis 60 to ice/day (or 400 to 2500 kg/h) Refrigerating power 40 to 250 kw Ready to plug or for local refrigeration units Evaporator for all refrigerants, pump- or dxmode Stainless steel completely Design and Dimensions typical measurements Compact - system System type A System type B (without refrigeration, including separator and crusher ) L w 0,8 1,0 H 2,3 3,3 3,3

Construction of the icemaker Advantages Low running costs: Low electric consumption due to high evaporation temperature Ice maker in stainless steel completely Durability Reliability Chip ice some cm big: Ideal ice temperature of -0,5 C, not subcooled Dull edges Suitable for sensitive products No clogging of ice when stored Long lasting cooling effect Steplessly adjustable size of ice chips BUCOdelot Falling Film ice makers for more than 20 years. More than 200 BUCOdelot ice makers in operation Heat Transfer Technology AG Bernastrasse 6, 3005 Bern, Switzerland Telephone: +41 (0) 3131024-01 sales@htt-ag.com Telefax: +41 (0) 3131024-15 www.htt-ag.com