Section 5.0: HAZARDOUS MATEIRAL STORAGE TABLE OF CONTENTS. A. Regulations, Standards and References 2. B. Scope 3. C. Approvals and Listings 3

Similar documents
Section 1.0: LAB VENTILATION TABLE OF CONTENTS. C. General Ventilation Considerations 3. D. Pressurization 7. E. Supply Air Arrangements 8

SECTION LABORATORY EQUIPMENT CONSTRUCTION STANDARD PART 1: GENERAL Scope of Standard

LABORATORY EQUIPMENT. A. Section Accessibility for People with Disabilities. B. Section Plumbing Basic Materials and Methods

Item Referenced and Amendments Building 1 Building 2 Analysis, Review and Remarks. Page 1 of 15

Adv. 8.4 Guidelines for Biosafety Cabinets Rev

YORK COUNTY DEPARTMENT OF FIRE SAFETY BUILDING PLAN REVIEW REQUIREMENTS

Safety Cabinets STORAGE. KEWAUNEE encouraging new discovery FLAMMABLE & CORROSIVE

Laboratories and Hazardous Materials. Company Overview

Chapter 34 Flammable and Combustible Liquids

SEMICONDUCTOR FABRICATION FACILITIES

SECTION SPECIAL EXHAUST SYSTEMS. A. Laboratory Ventilation and Hazardous Exhaust Systems. 3. Chemical Fume Hoods and Storage Cabinets

Scientific Equipment & Furniture Association SEFA Recommended Practices For Liquid Chemical Storage Cabinets

Flammable Liquid Storage

GASEOUS HYDROGEN SYSTEMS

SEMICONDUCTOR FABRICATION FACILITIES

Savard Labor & Marine Staffing, Inc. Fire Prevention Program Rev3/14

AMENDMENTS TO THE BUILDING AND FIRE CODE FOR THE CITY AND COUNTY OF DENVER

UNDERSTANDING SAFETY CABINETS

Laboratory Information

SEMICONDUCTOR FABRICATION FACILITIES

SEMICONDUCTOR FABRICATION FACILITIES

CHEMICAL FUME HOOD PROGRAM

Florida International University. Biosafety Cabinet Program

Introduction. Program Description. Section C.20 University of South Carolina Safety Program Guide FLAMMABLE AND COMBUSTIBLE LIQUIDS

Stillwater Area Community Services Center Inc.

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST

Working safely with flammable liquids

PART 2. Basic Code Requirements - Semiconductor & Microelectronic Facilities using HPM s

2008 NYC Fire Code. New Laboratory Standards. Operational & Maintenance Provisions effective July 2008

Hot Work Policy. Department of Risk Management. 1. Purpose. 2. Authority. 3. Scope

Products Solutions Services CT287. Hazardous Area Classifications and Protection Systems

California Fire Code (CFC) Part III contains requirements. Building and Equipment Design Features PART. Chapters 5 through 19

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE GENERAL INDUSTRY SAFETY STANDARDS PART 8. PORTABLE FIRE EXTINGUISHERS

Riverside County Fire Department Office of the Fire Marshal Market St., Ste. 150, Riverside, CA Ph. (951) Fax (951)

The Cannabis Industry: Fire Department Requirements

Summary of BBS Proposed Ohio Mechanical Code Rule Changes October 2016

Fire Prevention Plan

Part I Extraction Process Equipment

Osceola County Department of Fire Rescue and Emergency Medical Services

ICC Update - Laboratory Issues Code Changes / Proposals / Trends of Interest 10/2005

Business Fire Inspection. City of Guadalupe

***DRAFT - NOT FOR FILING***

City of Grover Beach Building Division Fire & Life Safety Requirements CANNABIS CULTIVATION, MANUFACTURING AND LABORATORY FACILITIES

2009 International Fire Code Errata. SECOND PRINTING (Posted April 6, 2010)

4/18/2017. *2012 edition of NFPA 99 has gone through a major overhaul. *This document is now a Code.

Flammable and Combustible Liquids Checklist

This policy is applicable to all DMS-owned, -leased and -managed facilities.

Fire Prevention Plan

PROPOSED CODE CHANGES FOR REVIEW BY THE FIRE CODE ACTION COMMITTEE

ICC CODE CORNER 2015 International Fire Code

BUILDING/FIRE CODE REFERENCES 2006 EDITION

Second Revision No. 5-NFPA [ Section No ] Supplemental Information. Submitter Information Verification. Committee Statement

OUTLINE FOR FIRE PREVENTION ACTIVITY

1. Researchers are familiar with the location and contents of: The lab s Chemical Hygiene Plan YES NO

CENTRAL STATE HOSPITAL PLAN SAFE USE HANDLING AND STORAGE OF FLAMMABLE AND COMBUSTIBLE LIQUIDS

Environmental Health and Safety Biological Safety Program Guidance Document

Flammable and Combustible Liquids

HOT WORK SAFETY PROGRAM:

ERRATA TO THE 2000 INTERNATIONAL FIRE CODE. Fourth Printing, January 2002 Updated March 29, 2002

Denver Fire Department Fire Prevention Division

REFERENCES TO ICC ELECTRICAL CODE - ADMINISTRATIVE PROVISIONS IN THE INTERNATIONAL BUILDING CODE

FIRE SAFETY DURING CONSTRUCTION, ALTERATION AND DEMOLITION

Lombard Fire Department Bureau of Fire Prevention COMMERCIAL HOOD & DUCT SYSTEMS

Large Family Daycare Guideline

Inspection Checklist Mechanical Rough in

University of California, Davis Laboratory Self-Inspection Checklist

Safe Operating Procedure

Defend In Place 2012 IFC Overview of Institutional Occupancies

LABORATORY SAFETY DESIGN GUIDE

GENERAL FIRE REQUIREMENTS SELF INSPECTION CHECKLIST

NC Mechanical Code. Land Use and Environmental Service Agency (Code Enforcement) Table of Contents

Public Input No. 52-NFPA [ Section No [Excluding any Sub-Sections] ]

The Science Behind Water Mist Protection of Typical Building Hazards

Safe Schools: A Health and Safety Check

Sample Safety Inspection Checklist for Schools

Goals of a Fire Prevention Program Fire Prevention Strategy Housekeeping Issues Flammable and Combustible Liquids Electrical Fire Hazards

Labeling to Article 690 of the National Electrical Code Routing and Protecting PV Cables

SEF Presents: Common Questions for a Chemical Safety Program. Wednesday September 20, 2017

Chapter 10: Laboratory Equipment

1.2 To ensure the safety of all persons working in or occupying a building where a hot work operation is performed.

Flammable. cabinets. Corrosive. cabinets. Toxic cabinets. and multirisk. Pesticide range. Fume hoods, filtering. cabinets - Ventilation

The Physical Environment Portal: Module 5, LS Leadership

Dear Concessionaire,

FIRE PROTECTION PROGRAM

PROSPECT COLLEGE HEALTH AND SAFETY PLANS FIRE PREVENTION PLAN

2012 International Fire Code Significant Changes. IFC Background. Purpose IBC and 2012 NFPA 101 Significant Means of Egress Changes

IBC Position on Bunsen Burner Use in Biosafety Cabinets

A. General Safety LAB/ROOM: INSPECTED BY: DATE:

Procedure DESCRIPTION/OVERVIEW

Mechanical Appliance and Equipment Inspection Checklist

Chapter 12 HOT WORK OPERATIONS. Purpose:

Riverside County Fire Department Office of the Fire Marshal Market St., Ste. 150, Riverside, CA Ph. (951) Fax (951)

Contents Chapters 4 & 5 of the 2012 Michigan Mechanical Code CHAPTER 4, MMC: VENTILATION CHAPTER 5, MMC: EXHAUST SYSTEMS

Residential-based Care Facility R-4 Guideline

Hot Work Program & Operational Guidelines. Environmental Health, Safety and Emergency Management (828)

Exit Routes, Emergency Action Plans, Fire Prevention Plans, and Fire Protection

First Revision No. 15-NFPA [ Chapter 2 ]

Permitting and Licensing for Hazardous Material Use and Storage

Department of Public Safety

CONSTRUCTION REQUIREMENTS FOR MOBILE FOOD FACILITIES

Transcription:

Section 5.0: HAZARDOUS MATEIRAL STORAGE TABLE OF CONTENTS A. Regulations, Standards and References 2 B. Scope 3 C. Approvals and Listings 3 D. Design 4 E. Venting Cabinets 4 Page F. General Installation Requirements 5 Page 1

A. Regulations, Standards and References Regulations: Biosafety in Microbiological and Biomedical Laboratories (BMBL) National Sanitation Foundation (NSF) Standard 49 OSHA 29 CFR 1910.1450, Occupational Exposure to Hazardous Chemicals in Laboratories International Fire Code (IFC) International Mechanical Code (IMC) National Fire Protection Association (NFPA) 2, Hydrogen Technologies Code National Fire Protection Association (NFPA) 45, Standard on Fire Protection for Laboratories Using Chemicals National Fire Protection Association (NFPA) 55, Compressed Gases and Cryogenic Fluids Code National Fire Protection Association (NFPA) 56, Standard for Fire and Explosion Prevention during Cleaning and Purging of Flammable Gas Piping Systems National Fire Protection Association (NFPA) 69, Standard on Explosion Prevention Systems National Fire Protection Association (NFPA) 91, Standard for Exhaust Systems for Conveying of Vapors, Gases, Mist, and Particulate Solids National Fire Protection Association (NFPA) 720, Standard for the Installation of Carbon Monoxide (CO) Detection and Warning Equipment National Fire Protection Association (NFPA) 99, Health Care Facilities Code Any addition referenced code or standard included in the IFC or NFPA as identified. Consensus Standards and References: ANSI/AIHA Z9.5 Laboratory Ventilation ANSI/ASHRAE 62, Ventilation for Acceptable Indoor Air Quality ANSI/ASHRAE 110, Method of Testing Performance of Laboratory Fume Hoods ANSI/ASHRAE 111, Practices for Measurement, Testing, Adjusting, and Balancing of Building Heating, Ventilation, Air-Conditioning, and Page 2

Refrigeration Systems B. Scope ANSI/ASHRAE 41.2, Standard Method for Laboratory Air-Flow Measurement ANSI/ASHRAE 41.3, Standard Method for Pressure Measurement Prudent Practices in the Laboratory, Committee on Prudent Practices for Handling, Storage, and Disposal of Chemicals in Laboratories National Institutes of Health Design Requirements Manual for Biomedical Laboratories and Animal Research Facilities National Research Council "Safe Handling of Radionuclides", International Atomic Energy Agency, Safety Series No. 1 ACGIH Industrial Ventilation Manual 1. The requirements of this Guide apply to all campus facilities, including leased properties in which hazardous materials are used, handled, or stored. It covers the design, construction, and installation of hazardous materials storage cabinets (including flammable liquid, corrosive material, and toxic material storage cabinets). ASU laboratory buildings, laboratory units, and laboratory work areas in which hazardous materials are used, handled, or stored. 2. Deviations from the Design Guideline must be reviewed and approved by EHS. 3. This document does not relinquish the owner or contractor from adhering to any and all applicable codes and standards for this project, requirements presented by the ASU Environmental Health and Safety (EHS), and including the requirements set forth in the ASU Design Guidelines. C. Approvals and Listings 1. The purchase and installation of storage cabinets for both flammable liquids and toxic materials shall be subject to review and approval of EH&S. 2. Flammable liquid storage cabinets shall be listed by a Nationally Recognized Testing Laboratory such as Underwriters Laboratories or Factory Mutual, or State Fire Marshal. a. NRTL listing or EH&S approval assures a minimum level of quality consistent with Code requirements and good practice. UL Listing is not required for corrosive or toxic material storage cabinets. Page 3

D. Design 1. Laboratories that store, use, or handle flammable or combustible liquids shall have one or more flammable liquid storage cabinets. 2. Flammable liquid storage cabinets shall not store in excess of the required quantities identified of any flammable or combustible liquids in accordance with the IFC and referenced NFPA codes and standards. 3. Flammable liquid storage cabinets shall be conspicuously labeled with the warning "FLAMMABLE KEEP FIRE AWAY" in red letters on a contrasting background. Doors shall be well fitted, self-closing and equipped with a self-latching device. 4. When flammable or combustible liquids present multiple hazards, the storage requirements for each hazard shall be addressed. For example, acetic acid is a corrosive and combustible material. Therefore, if It is stored in a flammable cabinet with other flammable materials, it shall be segregated (i.e., secondary containment). 5. Laboratories that store, use, or handle toxic liquids or solids shall have one or more approved and vented toxic material storage cabinet. 6. Where necessary, vented cabinets should be provided to store toxic materials, separated by hazard class. The vents shall be connected, preferably at the top of the cabinet to a supply ventilation system and the bottom of the cabinet to an exhaust ventilation system in accordance with the provisions of Section D of this chapter. Interior balance of the cabinet should be neutral to the outside. The cabinets should be compatible with the materials being stored. 7. Corrosive/toxic material storage cabinet shelving shall be constructed to prevent spillage of contents with tight-fitting joints, a welded or riveted liquid-tight bottom, a door sill of at least 2 inches, and lockable cabinet doors that are self-closing and self-latching. Corrosive materials should not be stored in metal cabinets unless the materials of construction are specifically treated to be corrosion-resistant. E. Venting Cabinets 1. Venting of storage cabinets is not required by Code and has not been demonstrated to be necessary for fire protection purposes. Additionally, if improperly performed, venting of a storage cabinet could compromise the ability of the cabinet to adequately protect its contents from involvement in a fire. However, there may be other health and safety considerations (e.g., odor control, control of potentially hazardous vapors) that dictate that the interior of a cabinet be ventilated. Early in the design phase, the designer shall discuss ventilation of hazardous material storage cabinets with Capital Programs Management Group, and Environmental Health and Safety. 2. If a flammable liquid storage cabinet is ventilated, then it shall be connected through the lower bung opening to an exterior exhaust in such a manner that it will not compromise the specified performance of the cabinet. The other metal bung shall be connected to an air supply located outside of the fire control area. 3. If the cabinet is not vented, then it shall be sealed with the bungs supplied or specified by the Page 4

manufacturer. 4. All toxic material storage cabinets should be vented. 5. Exhaust vent materials for hazardous material cabinets shall be compatible with contents of the cabinets. Vent materials for flammable liquid storage cabinets shall be resistant to high temperatures generated in a fire. Stainless steel, hard-soldered copper, and carbon steel are appropriate vent materials for flammable storage cabinets, provided the material is compatible with the intended service. Nonmetallic duct shall not be used to vent flammable storage cabinets. Compatible nonmetallic duct material, such as PVC, can be used for toxic material storage cabinet service. Polypropylene, which is combustible, is not appropriate vent duct material. The citation does not specifically authorize or forbid venting flammable storage cabinets. The citation states the following requirement: Piping, valves, fittings, and related components intended for use with flammable and combustible liquids shall be designed and fabricated from suitable materials having adequate strength and durability to withstand the pressures, structural stresses, and exposures to which they could be subjected. Such equipment shall be in accordance with nationally recognized engineering standards, be listed for the application or be approved. F. General Installation Requirements 1. Flammable liquid storage cabinets shall NOT be located near exit doorways, stairways, or in a location that would impede leaving the area. 2. Flammable liquid storage cabinets shall NOT be wall mounted. Good Practice Wall-mounted cabinets are not UL Listed or EH&S Approved. The mounting could breach the fire-resistive integrity of the cabinet. 3. Flammable liquid storage cabinets shall NOT be located near an open flame or other ignition source. An open flame or other ignition source could start a fire or cause an explosion if an accident or natural disaster brought the ignition source and flammable liquids or vapors together. 4. One room shall not contain more than three flammable liquid storage cabinets unless those groups of three cabinets are separated from each other by a distance of not less than 100 feet (30 m) OR if the building is protected by an automatic sprinkler system, the number of cabinets in any one group shall be increased to six. 5. Flammable and toxic/corrosive liquid storage cabinets shall be seismically anchored to prevent spillage of contents. Anchoring must not compromise the integrity of the fire rating, i.e., drilling holes through a free-standing cabinet. Page 5