Flow Switches. Series VHS, VKS, VH

Similar documents
Flow switch. Operating Manual. English manual page Page 1 of 15 Fax:

OEM Sensors for HVAC manufacturers Heat recovery Chiller

OEM Sensors for HVAC manufacturers Pool water

FSW300 Series Flow Switch

QVE1901U Flow Switch. Technical Instructions Document No September 20, Description. Features. Application.

A.YITE GROUP (Hongkong & Shanghai)

A.YITE GROUP (Hongkong & Shanghai)

1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W

1592P01. for liquids in piping DN

SIKA VK300 OR VK325 SERIES FLOW SWITCH Operating Manual

aquaconcept Cold water

Paddle Flow Switch. Pressure Control Flow Switch

Self-operated Temperature Regulators Series 43 Temperature Regulators Type 43-1 Type 43-2

Safety vacuum drying oven for flammable solvents

IRtech. E instruments. IRtech Radiamatic IR20 LS series. Infrared Technology

Retro-reflective Sensing range: 0mm to 2000mm

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Vacuum drying oven for non-flammable solvents

VL18LL-M/40a/118/128. VL18LL-M/40a/118/128. Fibre optic sensor for glass fibre optics. with M12, 4-pin metal connector

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions

LEAKSTOPPER RANGE Multizone water leak detection systems

Mounting and Operating Instructions EB 2231 EN

M7100 Pressure Transducer

Digital Panel Meter K3TL. Ordering Information. Low-cost, High-quality Digital Thermometer with Built-in Microcomputer. Accessories (Order Separately)

ST Wiring diagram. Product description. Standard temperature controller. Order number

Vacuum drying VD VDL series

aquaconcept Cold water

FLOW SWITCHES AND LEVEL SWITCHES CATALOG CATALOGUE DES DÉTECTEURS DE DÉBIT ET DE NIVEAU

1. Division 23 Section "Steam and Condensate Heating Piping" for steam and condensate meters.

TEMPERATURE CONTROLLER

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Dryer Systems Heat Regenerating Adsorption Dryers

Micro/Ultra Filtration System StamoClean CAT 430

Dryer Systems Heat Regenerating Adsorption Dryers

Leuze electronic. Dimensioned drawing. Electrical connection. Accessories: 150m ISO 9001

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

SECTION METERS AND GAGES FOR PLUMBING PIPING

Heaters, Thermostats and Hygrostats

More Precision. thermometer // Non-contact IR temperature sensors

Ramsey Series Motion Monitoring Systems Accurate Sensing of Speed Conditions on Rotating Shafts and Machinery

Temperature Sensor TRG Original Installation Instructions English

Cartridge Heaters. Metric FIREROD Cartridge. Applications and Technical Data

EW447-EW452 Series Mechanical Heat Meters FOR HEATING AND COOLING APPLICATIONS

VADA - Rain2Main Automatic Rainwater Controller

Thermo Scientific Ramsey TM Series Sensing Speed Conditions on Rotating Shafts and Machinery

SECTION METERS AND GAGES FOR HVAC PIPING

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

HERZ Regulating valve 4002

NORTH AMERICAN ADVANCED TECHNOLOGIES, INC.

B. Product Certificates: For each type of meter and gage, from manufacturer.

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode

Ready-to-Use Heat Tracing Solutions for Laboratory Applications. innovations in heat tracing

CR1 Series Triton Corrosion Resistant Washdown Heaters

Installation and instruction manual SOLAR STATION

RA 2000 Series RA 15/6T & TB Conversion Valve

Thermal Management Products & Accessories for Enclosures

GuideLine 2. Highly Visible Alignment Lasers for Visually Demanding Surfaces

for relative humidity and temperature with calibration certificates

Snifter. User Manual. Distributor

TK-5001, Pneumatic Room Thermostats General Instructions GENERAL INFORMATION INSTALLATION

LEAKSTOPPER 1 Single zone water leak detection system

541D19 SERIES. Technical Manual. A Division of Aquion Partners L.P.

Shop. Item Information. Interface I-100 For V-100/V-7x0. Send item information. Show item in shop. Add item to cart.

Vacuum generators VADM/VADMI

TK-1001, 1101, 1201, 1301, 1601

KOBOLD PSR/PS FLOW SWITCH

RA15/6T & TB Conversion Valve

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

Installation, commissioning and servicing instructions. Technical Characteristics. -Lead Plumbing Law Certifi ed by IAPMO R&T

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

Guide Specification - MasterFormat 2017 Style SECTION FLOW INSTRUMENTS PART 2 PRODUCTS 2.1 SECTION INCLUDES 2.2 ACCEPTABLE MANUFACTURERS

The Safest Connections...

Service instruction Cold

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

SCHMIDT LED Measured Value Display MD Instructions for Use

Inductive. Range. S410/IND Electrodeless Conductivity Sensors

CATALOG OF REPLACEMENT PARTS

Technical Data. Dimensions

Only for operating with ATEX certificated sensors DMT 99 ATEX E056/N5 Maximum optical input power Maximum radiation intensity Detection pattern

Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25)

FAST RESPONSE TEMPERATURE SENSORS 42.11a

Analog Transmitter AT1000 AT1

Beck. The differential pressure transmitter for air

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

! WARNING. Before using product, read and understand instructions.

ECOJET EJ-10E & EJ-7E ELECTRIC CONVECTION STEAMER W/TWIN GENERATORS PARTS AND SERVICE MANUAL

PULL-ON PEX PLUMBING SYSTEM

ST710-KHJV.03. Wiring diagram. Product description. Temperature controller. Order number

Vacuum generators. Festo core product range Covers 80% of your automation tasks

HERZ Differential Pressure Control Valve 4002

FACTORY AUTOMATION. Instruction Manual NBB20-L2-E2B-C-V1 NBN40-L2-E2B-C-V1 Inductive Sensor

GAS COMPONENTS ELECTRIC COMPONENTS WATER TECHNOLOGY MECHANICAL COMPONENTS TOOLS. Spare parts suitable for MIWE

Process Water Heater For Industrial Applications All Voltages, Single or Three Phase Up To 88 KW

More Precision. indusensor // Linear inductive displacement sensors

TIMER CONTROLLED DRAINS

OPTISENS TUR 2000 Technical Datasheet

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

More Precision. thicknesssensor // The sensor for precise thickness measurements

GESTRA. Product Overview. The optimum components for every application

INDEX APPLIANCE GAS WATER HEATER CONTROLS 150 ELECTRIC WATER HEATER THERMOSTATS 151 SNAP DISC CONTROLS/LIMITS/SWITCHES 152 GAS DRYER VALVES 153

Transcription:

Flow Switches Series VHS, VKS, VH

Reliable - Safe - Proven! Our tried-and-tested fl ow monitoring switches for liquids are used for two basic purposes: To ensure a minimum fl ow rate, e.g. of cooling water or lubricating oil (protects against running dry). To start a technical procedure when the fl ow begins. Function The fl ow monitoring switch comprises a paddle system (1) to whose end a permanent magnet is attached (2). Above this magnet is a reed contact (3), located outside the fl ow of fl uid. A second magnet (4) creates the force necessary to reset the switch back to the no fl ow position. Reed contact (3) Benefits that convince Adjustable switching point Low pressure drop Instant response High repeatability Max. pressure ratin2 BSP50 bar as an option Switching function dependent on fl ow rate alone, not on temperature or pressure The reed contact used as a sensing element consists of two ferro-magnetic contact blades located in a glass bulb fi lled with inert gas. This practically eliminates wear resulting from contact burning. This construction allows a useful life of up to 100 000 000 switching cycles. contact closes when liquid is fl owing contact opens if fl ow is interrupted Magnet (2) N S N S These settings can be changed by the customer if required. You can also adjust the switch point setting within the specifi ed range. Paddel system (1) Center Magnet (4) Options Specifi c set point adjustment, including special set points Optical fl ow indicator: LED in plug Reed contact for high switching performance Operating pressure up to 250 bar OEM design, proven in numerous series applications Flow For use in potentially explosive areas in consideration of manufacturer s declaration Recognized component ETL When the fl ow being monitored pushes against the paddle system, the paddle swings away. This changes the position of the magnet (2) in relation to the reed contact (3) and thus activates the contact. As soon as the fl ow is interrupted, the paddle moves back to its starting position, thus activating the reed contact once again. The force necessary to push the magnet back is provided by the two magnets repelling each other. Using magnetic force instead of the usual leaf spring means that the switch is considerably more stable in the long term and much less sensitive to pressure peaks. Types for OEM applications upon request. -2-

Flow switches with reed contact - series VHS / VKS Technical data Max. working pressure VHS... VKS... Max. medium temperature VHS... VKS... VKS...MKU Ambient temperature PN 25 PN 10 110 C 100 C 20 C (PN 10); 60 C (PN 2,5) 80 C (VKS...MKU 60 C) Protection class IP 65 Max. switching current 1 A Max. switching voltage 230 VAC, 48 VDC Max. rating 26 VA, 20 W Setpoint tolerance ±15 % Approvals Two different versions Flow switch with pipe section (inline type) nominal diameter DN 8 to DN 50 Electrical connection Standard Optional Optional Optional Z Power -3- Durchfluss Z Plug connector EN 175301-803-A incl. cable socket Plug connector EN 175301-803-A incl. plug with two LED for optical fl ow and power indication in plug (for switching voltages 24 V...230 VAC/DC). 4-pin-sensor plug M 12x1 acc. IEC 947-5-2 Connection cable 1,5 m Flow switch insertion type for direct installation from above, directly into the pipeline nominal size DN 50 to DN 200 Available materials Flow Switch - Brass - St. steel 1.4571 - Plastic NORYL PPO GFN3 - Brass with paddle system made of plastic Pipe section - Brass - St. steel - Copper solder connection - PVC solvent bonded connection Accessory Accessory part Length Order code Connection cable with 4-pin cable socket M 12x1, angle type molded lead, sheathing material PUR, screened, (Tmax = 80 C) - UL-approval 3 m 5 m 10 m XVT 2053 XVT 2009 XVT 2070 4 pin cable socket M12x1 angle type, unassembled VT 1331

Flow Switch - Inline Type ** stainless steel version: ** 60 mm at VHS 15 MA: Setpoint ranges (Water 20 C) Dimensions Type / Order code Size Process connection d1 increasing flow decreasing flow Max. flow rate l1 Nut size sw1 [mm] Brass St. steel VHS 08 M DN 8 ¼ BSP 2,1...2,7 1,8...2,4 45 11 27 27 VHS 10 M DN 10 ⅜ BSP 2,5...3,2 2,2...2,9 60 11 19 27 VHS 15 M DN 15 ½ BSP 3,4...4,2 3,0...3,8 67 11 19 27 VHS 15 MA DN 15 ½ BSP (male) 2,5...3,2 2,2...2,9 60 10 19 - VHS 20 M DN 20 ¾ BSP 7,0...9,1 6,4...8,2 120 15 27 32 VHS 25 M DN 25 1 BSP 13,5...17,0 12,0...15,5 195 15 32 41 VHS 32 M DN 32 1¼ BSP 15,5...20,5 14,5...19,0 240 15 41 46 VHS 40 M DN 40 1½ BSP 26,5...34,5 25,5...32,5 400 15 55 55 VHS 50 M DN 50 2 BSP 39,5...51,0 39,0...50,0 400 15 70 70 Materials and pressure drop diagram Materials Type Body Paddel system Pipe section VHS.. M-MS Brass Brass Brass* VHS.. M-VA St. steel St. steel St. steel VHS.. MK Brass PPO Noryl GFN3 Brass* VKS.. M PPO Noryl GFN3 PPO Noryl GFN3 Brass* * As an option, a copper tee piece, for soldered connections, can be supplied. This will alter the specifi ed setpoint ranges. -4-

Flow Switch with PVC-pipe section knurled union nut 3/4 " BSP Setpoint ranges (Water 20 C) Dimensions Type / order code Size Inside diameter d1 increasing flow decreasing Max. flow flow rate l1 l h VKS 15 M KU DN 15 20 5,1...6,9 4,9...6,5 50 16 54 113 VKS 20 M KU DN 20 25 9,4...12,3 9,1..11,9 100 19 66 118 VKS 25 M KU DN 25 32 10,7...15,2 10,4...14,8 100 22 78 127 VKS 32 M KU DN 32 40 17,0...22,6 16,8...22,5 150 26 98 155 VKS 40 M KU DN 40 50 VKS 50 M KU DN 50 63 * The values in brackets are valid for shortened paddle 21,8...30,1 (29,6...41,4)* 29,0...40,0 (37,6...50,0)* 21,6...29,9 (29,4...40,8)* 28,6...49,8 (37,4...49,8)* 200 (260)* 260 (350)* 31 118 166 38 144 180 Materials Body Paddel system Pipe section PPO Noryl GFN3 PPO Noryl GFN3 PVC -5-

Flow Switch - Insertion Type Setpoint ranges (Water 20 C) Type / order code thread connection Insert in Size increasing flow [m³/h] decreasing flow [m³/h] Max. flow rate [m³/h] Laid length l3 [mm] DN 50 1,9...2,7 1,8...2,6 30 VHS 05 M ½ BSP DN 80 5,0...8,0 4,9...7,9 80 DN 100 8,3...12,5 8,2..12,4 150 51 ±1 DN 150 17,5...25,0 17,4...24,9 200 DN 100 5,7...6,3 5,6...6,2 100 VHS 06 M ½ BSP DN 150 11,0...13,0 10,9...12,9 150 111 ±1 DN 200 25,0...27,0 24,9...26,9 200 DN 50 3,8...4,9 3,7...4,8 30 VHS 01 M soldering/ weldingadapter DN 80 9,0...14,3 8,9...14,2 100 DN 100 13,0...18,8 12,7...18,4 150 24 ±1 DN 150 33,0...46,0 32,9...45,9 200 Every fl ow switch type is suitable for integration in pipes of different sizes. For example the type VHS 05 M can be inserted into DN 50 to DN 150 pipes without modifi cation but setpoint ranges will differ. Materials Materials Type Body Paddel system Max. flow rate VHS.. M-MS Brass Brass see above table VHS.. M-VA St. steel St. steel see above table VHS.. MK* Brass PPO Noryl GFN3 upon request VKS.. M* PPO Noryl GFN3 PPO Noryl GFN3 upon request * available with connection ½ BSP, not available with soldering/welding nipple. -6-

Flow Switch with micro switch, Type VH A micro switch used as the sensing element allows a higher electrical switching capacity than the reed switch. The resetting force required by the paddle system is produced by a leaf spring. The following versions are available: With pipe section,female thread, DN 10 to DN 50 With pipe section,male thread, DN 15 only Insertion type for direct installation using soldering nipple on request Standard material is brass Technical data Max. working pressure PN 25 Max. medium temperature 100 C Protection class IP 65 Contact Change-over contact Max. switching current 5 A Max. switching voltage 250 VAC Max. rating 1250 VA Setpoint tolerance ±15 % Setpoint hysteresis 10...30 % Max. pressure drop at max. flow approx.0,01 bar Type / order code Size Process connection Setpoint ranges (Water 20 C) decreasing flow Max. flow rate Water Dimensions [mm] L H VH 010 I DN 10 ⅜ BSP 4,0...5,0 10 50 85,5 VH 015 I DN 15 ½ BSP 5,0...6,0 20 50 85,5 VH 015 A DN 15 ½ BSP (male) 4,0...5,0 20 60 85,5 VH 020 I DN 20 ¾ BSP 8,0...10,0 40 50 88,0 VH 025 I DN 25 1 BSP 17,0...20,0 60 50 92,5 VH 032 I DN 32 1¼ BSP 24,0...28,0 100 50 95,0 VH 040 I DN 40 1½ BSP 43,0...50,0 150 50 97,5 VH 050 I DN 50 2 BSP 69,0...83,0 250 50 108,0-7-

Our Production and Sales Range Flow Sensors without moving Parts Turbine Flow Sensors Flow Switches Pressure Gauges and Pressure Sensors Industrial Thermometers Electronic Digital Thermometers, Dial Thermometers Measuring Instruments Temperature Sensors Your competent partner for measurement and control Calibrators, DKD-Laboratory...measurement...control...calibration Phone: 0700 CALL SIKA Phone: +49 5605 803-0 Fax: +49 5605 803-54 E-Mail: info@sika.net Internet: http://www.sika.net Struthweg 7-9, 34260 Kaufungen P. O. Box 1113, 34254 Kaufungen Germany Flow Switch_e 05/2012