The PA 600LI Heat Recovery Ventilation unit has been designed to serve the following small scale applications

Similar documents
The PA 600LI Heat Recovery Ventilation unit has been designed to serve the following small scale applications

HRU ECO 4. System 4 Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Appendix Q Eligible

Itho Advance heat recovery ventilation unit. comfortable. indoor climate

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

Gemini EC. Engineered with Excellence, Specified with Confidence All-in-One Renewable Energy Climate Control

MRXBOX90 - WHOLE HOUSE HEAT RECOVERY UNIT

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning

Sentinel Demand Energy Recovery Ventilation

Limited Lifetime core warranty. 5-year warranty on balance of unit.

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation

MRXBOXAB-ECO3 MRXBOX-ECO3

MRXBOXAB-ECO2 MRXBOX-ECO2

Lo-Carbon Sentinel Kinetic Horizontal

Heat pump & cooling unit in one

KOMFORT EC DB Suspended heat recovery air handling units

Mikael Börjesson Product manager. Commercial air handling units Ventilation functionality Building management system integration

TECHNICAL SPECIFICATIONS

For an indoor atmosphere that makes you feel good

Heat Recovery Units. Heat Recovery 1

FRESHBOX 100. Single-room heat recovery unit. Air capacity up to 100 m³/h Heat recovery efficiency up to 96 %

TECHNICAL SPECIFICATIONS - CW-80T AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

Ventilation. Product Information

Domestic & Commercial Fans

CI/SfB (57.7) 2nd edition

The Sentinel Kinetic Horizontal Range

CI/SfB (57.7) 1st Edition. Vent-Axia Sentinel Kinetic Horizontal Range. Vent-Axia MVHR Units

DEMAND-CONTROLLED HOME VENTILATION

Residential Heat Recovery Ventilation. REHVA European Guidebook No 25

SPECIFICATION casing manufactured from aludip steel in white low energy DC external motor aluminium plate heat exchanger

TECHNICAL SPECIFICATIONS - CW-80T-TWIN AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

SUNWARM AIR SOLAR PRE-HEAT VENTILATION SYSTEM

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

Small Room Heat Recovery Ventilation

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%

The ultimate fresh air solution.

HRU SINGLE DWELLING HOUSES - BALANCED AIRFLOW WITH HEAT EXCHANGER AKOR ST HR Series

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

The new Xcell EC High Efficiency Range Fresh air pure and simple

Healthy, comfortable and energy-efficient ventilation

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

VENTILATION AND HEAT RECOVERY

INTRODUCTION. JAU /JCC/JVC Series Jet Fans - for car park ventilation

ComfoAir Q. Mechanical Ventilation and Heat Recovery

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

MODEL: BV400 Part No:

Technical Information HXV - HRV Ventilation

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW

TECHNICAL INFORMATION DanX Swimming Pool Air Management

Residential Carbon Friendly Ventilation SAP Q Eligible. ventilation

Healthy, comfortable and energy-efficient ventilation

EC Series Wall Unit Humidifier

Heat pump and energy recovery systems

Aegean Range. A new range of fan coils for heating and cooling commercial applications

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

Review on Waste Heat Recovery Techniques in Air Conditioning Application

Daikin Blueprint: Delivering Hot Water with a Chiller

Efficient energy recovery in AHU. DOHA, Qatar Timo Schreck Enventus AB, Sweden

Heat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing

ENG. IDEO 325 Ecowatt. Installation Manual

Lo-Carbon Sentinel Kinetic Range Overview

Energy saving ventilation Air handling units (Catalogue no. 2) Industrial and commercial ventilation. (Catalogue no. 1)

Introducing the RetroVent

ErP. The ErP Directive. New values for fans

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans. Topvex SoftCooler TR. Specification data

Horizontal rotor heat recovery ventilation unit RH 5. Vertical rotor heat recovery ventilation unit RV 9

HOTLINE:

HEAT RECOVERY VENTILATION For healthy, energy efficient ventilation

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

Chrome. Approximately 26 seconds drying time. 1.0kW Automatic Eco Fast Dryer Epoxy Coated. 1.2mm thick steel cover

The ultimate in air handling units: directly and indirectly fired

Rotors overview. Quick guide GOST VDI 6022

TECHNICAL SPECIFICATIONS - CW-80T-TWIN USA & MEXICO

THE EFFECT OF ENTHALPY RECOVERY VENTILATION ON THE RESIDENTIAL INDOOR CLIMATE

AIR HANDLING UNITS RIS P EKO 3.0. New range - 5 sizes, 20 models! Efficient EC. E f f i c i e n c y up to 94%! E x t r e m e l y low height! fans!

WORLD VENTILATION LEADER SINGLE-ROOM AIR HANDLING UNITS WITH NEAT RECOVERY VENTILATION SYSTEMS

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

MODEL: DV72 R & L. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual

Series VENTS VUT R WH ЕС

VEX250H with rotary heat exchanger and EXact control system

Air is our element. energy recovery our passion. Rotors overview. Quick guide GOST VDI 6022

Xcell 270 Longlife DC wholehouse heat recovery unit

Caice Attenuator Selector - Specifier Edition

Indoor Swimming Pools:

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

WORKSHOP VENTILATION- PSYCHROMETRICS-AHU

Whole Home Heat Recovery Ventilation

SINGLE-ROOM HEAT AND ENERGY RECOVERY UNITS

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR)

Function of the FENIX Hydrodynamic Trap working on Variable Load Applications

NEW SECTION: ROTARY HEAT EXCHANGER WITH A HEAT PUMP Effective and smart!

Mystery of Sustainable Heat Exchange Material Heat Recovery Ventilator(HRV)

EHH SERIES DRAW THROUGH FAN COILS CFM

Air Handling Units. Real HVACR people who understand your needs.

The ultimate in air handling units: directly and indirectly fired

Zehnder Comfosystems. ComfoAir 180 Datasheet

CI/SfB (57.7) 1st Edition. Lo-Carbon Response/SELV dmev Unit. A new generation of Lo-Carbon continuous running fans

Transcription:

Heat Recovery Ventilation Systems Data Sheet PA600LI The PA 600LI Heat Recovery Ventilation unit has been designed to serve the following small scale applications Houses ranging in size from 100 300 M2 in floor area. Small office spaces (up to 8 people). School classrooms. Crèches. Care-homes. Doctors/Dentists clinics Private swimming pools. PA600LI 1 of 1 ProAir Heat Recovery Ventilation Systems

If the applications are larger such as a 500M2 house two or more units can be used. It utilises a counter-flow plate exchanger at its core and consequentially has a high sensible efficiency. This means that the supply air temperature will always be within 2 o C of the exhaust air temperature even at a very low sub-zero temperature of the incoming fresh air. The PA 600LI is of the highest efficiency in its class, achieving up to 94% in noncondensing conditions and achieving a specific fan power down to 0.57ws/l of air. In condensing conditions (colder) this can increase to over 97%. Indoor (1) Fresh In (4) Temp 20.0 C 18.1 C Relative Humidity 50% 19% RS160 heat transfer 1950 [W] Water 0.76kg/h Outside (3) Extract (2) Temp -5.0 C 3.1 C Relative Humidity 95% 100% Figure 1. Figure 1 shows a typical winter scenario. Here almost 2Kw is transferred from the outgoing air to the incoming air when 250m 3 /hr is moved through the system in both directions. PA600LI 2 of 2 ProAir Heat Recovery Ventilation Systems

The main components of the ProAir PA600LI unit are Heat Exchanger 1. Heat Exchanger 1of 2. Fans 2of 3. Filters 2of 4. Control circuitry 1of 5. AHU casing 1of The heat exchanger is the heart of the unit. It is an air to air counter flow heat exchanger and its thermal effectiveness is extremely high. This is achieved by having The two air flows in a pure counter flow arrangement, Balanced airflow in both directions. No leakage between the airflows, The airflows directed uniformly at the intakes of the heat exchanger Having minimum heat conducted along the length of the duct wall. The eskremo version of pure polystyrene used for the plates is inert in most applications and is suitable for air temperatures between 50 C and +50 C. Material Height No. of plates Surface area Plate thickness Pure polystyrene 394 mm 164 34.686 M2. 0.2 mm The performance of the heat exchanger is dependent on the temperature difference between the two air streams. This explains why the supply air into the space is still 17.7 C even though the air entering (outdoor temperature) is -20 C as shown in the table. Outdoor Temp C Supply Temp C Recovered Heat watts Return Temp C Airflow m3/hr Condensate l/hr Return RH Exhaust Temp C -20 17.7 2547 20 200 1.16 50% -6.0-15 18 2228 20 200 1 50% -2.9-10 18.2 1906 20 200 0.82 50% 0.1-5 18.4 1583 20 200 0.62 50% 2.9 0 18.6 1257 20 200 0.4 50% 5.4 5 18.7 928 20 200 0.16 50% 7.9 10 19 607 20 200 0 50% 11.0 15 19.5 303 20 200 0 50% 15.5 20 20 0 20 200 0 50% 20.0 PA600LI 3 of 3 ProAir Heat Recovery Ventilation Systems

Fans The fans are high efficiency backward curved 190mm light-weight plastic impellors mounted on external rotor, electronically commutated, medium voltage, DC motors, all fitted into a customised sound absorbent dense polyethylene scroll. Figure 2 shows the performance of these fans when fitted into the PA600Li unit with pressure absorbed by the heat exchanger, filter and inlet spigot. The Y axis shows the amount of pressure that these exert on the fan across the range of airflows. Figure 2. The performance of the unit will be further affected by connected components such as ducting, air terminals, inlet/exhaust terminals, etc. The pressure exerted on the fans by these components is known as the external pressure. Figure 3. PA600LI 4 of 4 ProAir Heat Recovery Ventilation Systems

The PA600LI has been connected to a simulated installation network in the ProAir test laboratory and Figure 3 shows the result at various speeds. A typical HRV installation should develop an external pressure of between 15 and 50 Pa per leg, (extract - exhaust and Fresh supply) depending on speed. A related aspect of fan performance and airflow is the power used in various situations. Figure 4 In Figure 4 we can see that the unit uses considerably less power on a proportionate basis when smaller volumes of air are being moved. Correct sizing of the unit for the application ensures that the motors driving the fans, which are running continuously, are within their comfort zone. This allows them to run very efficiently at lower speeds. The target is to move the required amount of air at the lowest fan speed and hence achieve high efficiency with the resulting low sound levels. This is addressed at design and commissioning stages. The unit uses considerably less power on a proportionate basis when smaller volumes of air are being moved. Correct sizing of the unit for the application ensures that the motors driving the fans, which are running continuously, are within their comfort zone. This allows them to run very efficiently at lower speeds. The object of the exercise is to move the required amount of air at the lowest fan speed and hence achieve high efficiency with the resulting low sound levels PA600LI 5 of 5 ProAir Heat Recovery Ventilation Systems

Filters The PA600LI unit has filters in both the supply and return legs. Both filters have the primary function of protecting the working parts and surfaces of the ventilation unit - the fans and the heat exchange surface. They also perform the very important job of ensuring that the air supplies are kept clean. The he supply filter also collects finer particles which might be detrimental to the health of the users. Figure 5 is a guide to the common particles and their size ranges, found in everyday life. Figure 5. PA600LI 6 of 6 ProAir Heat Recovery Ventilation Systems

Figure 6 The F7 filter lies between the electronic and the pleated filter on the above chart. The filters are easily accessible. Checking and replacing them is a relatively easy task. PA600LI 7 of 7 ProAir Heat Recovery Ventilation Systems

Controls The HRV system is normally run at a speed to suit the application which is set during commissioning, with a facility for a timed boost over-ride. This timed boost is manually operated by means of one or more push-to-make switches located at wet areas (shower areas). This switch line as shown in Figure 7 sends a low voltage signal to the unit, to go to a higher speed for a preset time. 6 Core Alarm Cables SELV HRV Unit 13 AMP Socket Further wet rooms Off Normal On Boost 2 gang switch 1 gang switch Main Control Central area of house Kitchen/ Utility Outside wet rooms (Showers) F Figure 7. Where Heat Recovery Ventilation is used to help conserve energy in Winter time some users may decide that it is not useful outside of the heating period and may switch it off. At this time, windows and doors will be open and the heat recovery feature will not be used. However the system will still be required periodically to deal with odours and water vapour. This is why the ProAir system incorporates a wake-up facility, where by pressing a boost switch, the unit will run on boost for the timed period, even when the on/off switch is in the off position. As shown in Figure 7, the power for the system is by means of a standard socket. The layout of the Control Board is shown Figure 8. Adjustment to the system is made by the manipulation of Dip switches on the control board. The following items can be adjusted by means of the dip switches. 1. Fan speed; using range and range divider switches. PA600LI 8 of 8 ProAir Heat Recovery Ventilation Systems

2. Max speed setting, labeled, boost power, on board layout drawing below. This is a facility for use in smaller applications where it is not necessary to run the system at full speed on boost. 3 Boost time allows adjustment of time on boost. Figure 8 The range divider settings shown in Figure 9 indicate how to control the fans to move certain volumes of air. There is an option of 10 control points within the range. This means that each installation can be commissioned to match the application exactly with the required air-flows. The ProAir technician will programme the two speeds suitable for your house size. PA600LI 9 of 9 ProAir Heat Recovery Ventilation Systems

P 60 Range Divider (V) Speed (m/s) RANGE 1 2 3 4 5 6 7 8 Control voltage 1.3V 1.1V 0.9V 1 m/s 0.6 0.5 0.3 m3/hr 38 32 19 Control voltage 1.9V 1.6V 1.3V 1.1V 2 m/s 1 0.8 0.6 0.5 m3/hr 64 51 38 32 Control voltage 2.5V 2.1V 1.8V 1.5V 1.2V 1.0V 3 m/s 1.5 1.2 0.8 0.7 0.5 0.4 m3/hr 95 76 51 45 32 25 Control voltage 3.2V 2.7V 2.2V 1.9V 1.6V 1.3V 1.0V 4 m/s 2.2 1.8 1.2 1 0.8 0.6 0.4 m3/hr 140 115 76 64 51 38 25 Control voltage 4.2V 3.4V 2.9V 2.4V 2.0V 1.6V 1.3V 0.9V 5 m/s 3.7 2.4 1.9 1.3 1.1 0.8 0.6 0.3 m3/hr 235 153 121 83 70 51 38 19 Control voltage 5.5V 4.5V 3.7V 3.1V 2.5V 2.1V 1.6V 1.2V 6 m/s 4.8 3.9 3 2.1 1.5 1.2 0.8 0.5 m3/hr 305 248 191 134 95 76 51 32 Control voltage 7.7V 6.0V 4.9V 4.0V 3.3V 2.6V 2.0V 1.4V 7 m/s 6.8 5.3 4.2 3.3 2.4 1.7 1.1 0.7 m3/hr 433 337 267 210 153 108 70 45 8 Control voltage 7.7V 6.0V 4.9V 4.0V 3.3V 2.6V 2.0V 1.5V m/s 6.8 5.3 4.2 3.3 2.4 1.7 1.1 0.7 m3/hr 433 337 267 210 153 108 70 45 1 2 3 4 Boost Control voltage 10.4V 7.2V 5.2V 4.2V m/s 7.9 6 4.7 3.7 m3/hr 503 382 299 235 Figure 9 PA600LI 10 of 10 ProAir Heat Recovery Ventilation Systems

Unit Size Figure 10 P PA600LI 11 of 11 ProAir Heat Recovery Ventilation Systems

Duct Connections There are 4no 150mm connections on the unit. There are 2 options for connection to the outside and the house. Option 1 Supply to Extract from Fresh air Exhaust air to living areas outside ply to wet areas wet areas from outside outside Option 2 enables the connections to be exactly the reverse of those in Option 1. This means that Exhaust and Fresh air connection to the outside is the on the left, with Extract from wet areas and Supply to living areas on the right hand side. Furthermore, in both options there is a side-entry connection where the exhaust and/or supply connections can be availed off for certain installation situations. This removable plug can be reinserted on the top of the unit to facilitate this side connection configuration. PA600LI 12 of 12 ProAir Heat Recovery Ventilation Systems

Technical Specification. Length Width Height Weight Casing: Heat exchanger 1.025 m 0.485 m 0.680 m 28 Kg Expanded polyethylene fire-rated class O Type Counter-flow plate exchanger Material Pure Eskremo Polystyrene. Filters Exhaust air Fresh air Fans: Duct Connections G4 grade media in cardboard panel 390*210*50mm G4 grade media in cardboard panel 390*210*50mm 2no FB190C Backward curved centrifugal impellors 4no 150mm Round Specific Fan Power (SFP) Down to 0.57 ws/l Heat Exchanger Efficiency over 90% Power Cable Lengths 220V AC Mains cable (230V AC) 2m Control cable lengths variable. Site dependent Condensate Drain Connection required to waste pipe within house. SAP Appendix Q listed Installation Left or right hand options. PA600LI 13 of 13 ProAir Heat Recovery Ventilation Systems