Swegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION

Similar documents
Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION

Swegon CASA R85. Ventilation unit with rotary heat exchanger HOME VENTILATION

OVERVIEW and SYSTEM GUIDE. Swegon CASA. Residential ventilation for optimal operating economy and the greatest comfort.

Swegon CASA R120. Instructions for installation, operation and maintenance. R120_h_EN-m

Swegon CASA. R85, version B. Instructions for installation, operation and maintenance. R85B_h_EN-m

Swegon CASA W80 EC, version B

Swegon Home Solutions CASA. W3 Smart. Installation, commissioning and maintenance instruction. W3_f_EN-t

CASA. W5 Smart. Installation, commissioning and maintenance instructions. W5_d_EN-t

Swegon Home Solutions CASA. W9 Smart. Installation, commissioning and maintenance instruction. W9_e_EN-t

Contents. Technical Description of the Air Handling Unit General, Specification Function, Functional Sections

Swegon CASA R85, version B

Swegon Home Solutions CASA. R3 Smart. Installation, commissioning and maintenance instructions. R3_f_EN-t

Heat recovery unit RDKS

Swegon Home Solutions CASA. R3 Smart. Installation, commissioning and maintenance instruction. R3_d_EN-t

Swegon Home Solutions CASA. R2 Smart. Installation, commissioning and maintenance instruction. R2_a_EN-t

Swegon Home Solutions CASA. W4 Smart. Installation, commissioning and maintenance instruction. W4_c_EN-t

Flexit air handling units C2 and UNI 2, 3,4

Flexit air handling units UNI 2, 3 og 4

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

COMPACT Air & Heat. Contents

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

KOMFORT EC DB Suspended heat recovery air handling units

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

CONDOR. Supply air ceiling QUICK FACTS

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams

TopMaster Air Handling unit. Technical data

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

FRESHBOX 100. Single-room heat recovery unit. Air capacity up to 100 m³/h Heat recovery efficiency up to 96 %

Series VENTS VUT R WH ЕС

Description of the functions, IQlogic

GOLDTM. Air Handling Units with Built-in Control Equipment that offer Economical Operation.

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

Residential Heat Recovery Ventilation. REHVA European Guidebook No 25

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

PRODUCT DATA COMFORT 300 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 325 m 3 /h

PRODUCT DATA COMFORT 302 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 345 m 3 /h

iq Star LYRA II chilled beam cassette

PRODUCT DATA COMPACT S BY NILAN. Sanitary hot water production. Passive heat recovery. Comfort heating. Ventilation < 375 m 3 /h. Active heat recovery

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

Heat Recovery Air Handling Units

PRODUCT DATA VPL 28 BY NILAN. Ventilation & active heat recovery. Active heat recovery. Comfort heating. Comfort cooling.

PRODUCT DATA VPL 15 TOP M2 BY NILAN. Ventilation & active heat recovery. Active heat recovery. Comfort heating. Comfort cooling.

CHILLED BEAM CASSETTE IQ STAR LYRA

SINGLE-ROOM VENTILATION. for schools and public spaces

Manual. Document ENG

UV-TURBO HOODS. Product Brochure

TSEK VHR EC HEAT RECOVERY UNITS

Zehnder ComfoAir 550. Ventilation unit

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.

Primo Hotel. General. Indoor climate units for hotel rooms

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

DOMEKT. Heat Recovery Air Handling Units

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

VERSO Air Handling Units

VEX100 series Air handling units with cross-flow heat exchanger

FUNCTION MANUAL, INSTALLATION GOLD RX/PX/CX/SD Generation F. Applicable to Program Version 1.27 and newer versions

Ceiling diffusers. Type DLQL

Domestic & Commercial Fans

Apartment Ventilation. "Microbox" Continuous Mechanical Extract Units

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

System technology. Demand controlled ventilation WISE.

Instructions for the BASIC Air Handling System, Sizes General 1.1 Description of the System

Heat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing

VERSO Air Handling Units

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

External insulated volume. control damper

ADAPT Parasol EX. Energy-saving, suspended comfort module QUICK FACTS

MODEL: BV400 Part No:

PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h

Silencer Preheater unit Electric post-heating unit Water circulated post-heating unit CO 2 sensor %RH sensor Pressure difference switch LON converter

TURBO HOODS. Product Brochure

That allows for installation of a lowresistance ducts system directly from the appliance. CONSTANT FLOW FANS

Vallox INSTRUCTIONS FOR USE AND MAINTENANCE. Compact. Supply and extract air ventilation with heat recovery

VERSO-P, VERSO-R Series Air Handling Units with C3 Control System Electrical Installation and Operation Manual

66 on. Central ventilation system ZLS-DV EC according to DIN Central ventilation system ZLS EXTRACT AIR FIRE PROTECTION OUTSIDE AIR

Energy saving ventilation Air handling units (Catalogue no. 2) Industrial and commercial ventilation. (Catalogue no. 1)

ROOM-BY-ROOM DEMAND CONTROLLED HEAT RECOVERY VENTILATION

CASSETTE UNIT. Comfort Circle

Swegon CASA. duct coils for heating. the supply air

Building Regulations Approved Document F1 Means of Ventilation April 2006

Sentinel Demand Energy Recovery Ventilation

Air heater/cooler in combination with ground source heat pump

Demand-controlled Ventilation Leading edge products for demand-controlled ventilation

Orion-Opus LØV-R with Sirius

TECHNICAL SPECIFICATION

Breathe Fresh Air at Home

Models Vallox 096 MC R Vallox 096 MC L. Document D2609 MANUAL. Valid from Type Updated Manual.

TopMaster Air Handling Unit

TTC. TTC Active supply air diffuser. Product description. Introduction SUPPLY AIR DIFFUSER - ACTIVE [CEILING MOUNTED] Simplicity

Lo-Carbon Sentinel Kinetic Horizontal

LTR-3-EC LTR-3-ECE PLANNING, INSTALLATION AND OPERATION INSTRUCTIONS

iq Star LYRA II chilled beam cassette

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

GOLD RX, GOLD RX 12 GOLD RX,

Ventilation unit Zehnder ComfoAir 200

WHHR Midi & Midi Lite

Transcription:

Swegon CASA R120 Ventilation unit with rotary heat exchanger Ventilation unit for residential houses, multi-storey buidings and holiday cottages under 230 m 2. The unit is equipped with rotary heat exchanger. Suitable also for renovation projects. Maximum air volume: 120 l/s. Temperature efficiency: up to 80 %. Low sound level. For installation in a machine room, storage space, laundry room, etc. A separate extract air connection for the cooker hood, and the extract air does not pass the heat exchanger. The ventilation system can be controlled from a separate control panel or from the cooker hood. Premium control technique. HOME VENTILATION R120_g_EN-p

Technical data General The Swegon CASA R120 is an ideal ventilation unit for homes and similar premises. The unit has a RECOnomic rotary heat exchanger for high heat recovery performance. The ventilation unit is designed to be mounted on a wall by means of the installation kit included in the supply. It is also possible to mount the unit against the ceiling with a ceiling mounting frame, available as optional equipment. Casing The casing is made of double-skin sheet steel with an intervening layer of cellular polyethylene as insulation. The external surfaces of the ventilation unit have a powder-painted, baked finish in a white tone (RAL 9016), the hinged front panel likewise, which is easy to open for inspection and servicing. The Swegon CASA R120 with the front panel open. Fans The fans have low-energy, economical, type EC directcurrent motors, whose power consumption is substantially lower than that of traditional fans driven by AC motors. The advantage of EC fans is that their speed is variably controllable and their efficiency is high even when they operate in the lower speed range. The power supply and control cables have quick-fit connectors and the fans can be easily removed from the unit, if required. Filters The unit has a class F7 fine filter for the supply air and a class G3 wide-mesh filter for the extract air. Heat exchanger The ventilation unit has Swegon's patented RECOnomic rotary heat exchanger. The heat exchanger rotor is composed of aluminium foil which forms a great number of passages through which the air flows. As the rotor rotates, heat is stored in the passages on the warm extract air side, and is emitted to the cold air on the supply air side. Even though the same surfaces are in contact with both the extract air and the supply air, there is very little risk that odour transfer will occur. The temperature efficiency is approx. 80 %. A rotary heat exchanger normally never freezes; it maintains its high temperature efficiency regardless of the outdoor temperature. The heat exchanger is driven by a motor of its own. The power supply and control cables have quick-fit connections and the heat exchanger package can be unfastened if required and withdrawn from the unit. The energy-efficient heat exchanger in the Swegon CASA R120. 2

Control System General The ventilation unit is controlled from the Premium control panel, which is standard equipment and from which you can also read and change settings. You can also select three different fan speeds from the Premium cooker hood. Control from a Premium control panel A Premium control panel can be installed at an optional location, recessed in a junction box or surface mounted on the wall. It can be located near the ventilation unit or somewhere else, and then must be connected to the unit via a 20 metre long modular cable. An extra control panel can also be connected, if it is desirable to control the ventilation unit from several places. Selectable functions Application. The unit can be started and stopped. Fan speed. The ventilation unit fans can be set and controlled to operate at five different speeds. The display indicates the Away mode when the fans run on their lowest speed and indicates the Home mode when the fans are running at normal speed. The speed of the supply air fan can deviate from that of the extract air fan and the speed is controlled from the control panel. Timer. The 24-hour/weekly timer has four programs. You can set the desired times if you want the unit to activate a desired function. The unit runs in the economical minimum speed mode at other times (Away). Functions: Home, Away, Boost, Cool. You can also select the temperature of the supply air. Temperature. You can set the desired start temperature of the electric air heater for reheating (optional item) within a range of 13 20 C. You can also shut off the reheating function. Negative pressure compensation. Negative pressure arises in the home when a separate cooker hood or central vacuum cleaner is used, since the extract airflow becomes higher than the supply airflow. This function compensates the negative pressure by automatically increasing the supply airflow. A signal from a contact in the cooker hood or the central vacuum cleaner is required. Summer operation. When certain limit values are met, the ventilation unit stops the heat exchanger (when heat recovery isn t needed). The ventilation unit is controlled from the Premium control panel. Summer night cooling. The function starts, if certain temperature conditions are complied with. The heat exchanger in the unit stops, the electric air heater is switched off and control system increases the speed of the fans. The cooler air at night, for instance, is then utilised for cooling the home. The fan speed can be selected. Cooling energy recovery. In the summer, when the indoor air is cooler than the outdoor air, the heat exchanger starts up. Fireplace switch function. The function generates excess pressure in the home and brings about an updraught in the chimney, which prevents smoke from entering the room when you light a fire. Display of the operating speed. The operating speed is continuously shown as text on the display screen. Service reminder. The service reminder interval can be set to a period ranging between 3 12 months. Automatic functions Alarms. Indicate the need for filter change or servicing and a possible disruption in operation. Heat exchanger. Starts and stops in response to signals from the temperature sensor. Overheating protection. For the motors and the electric air heater. Freeze protection. Prevents freezing in the heat exchanger. 3

Control from a Premium cooker hood Selectable functions The control panel of the cooker hood has three pushbuttons. Besides switching the cooker hood s lighting on and off, two control functions can be set as follows: Fan speed. The fans in the ventilation unit can be controlled to operate at three speeds: away/home/boost. The supply air fan can operate at a lower speed than that of the extract air fan. The period for operation in the boosted speed mode is preset to 60 minutes, after which the ventilation unit fans will decelerate to normal speed. The shut-off damper of the cooker hood. When preparing food or carrying out a similar activity, a 30, 60 or 120 minute damper-open period can be selected. Control of the cooker hood shut-off damper 30/60/120 min. indication Lighting Ventilation unit fan speed Away, home, boost Demand regulation (control) Demand control is possible with the following optional equipment: Timer. 24-hour/weekly timer with settable times, for when you want the ventilation unit fans to run at normal speed. At other times, the unit runs in the economical minimum fan speed mode. Boost timer. A manual pushbutton switch that can be installed at an optional location. The pushbutton switch can be located in a laundry room or the like, for example. Fireplace switch. A manual pushbutton switch that can be installed at an optional location. The function generates excess pressure in the home and in this way causes an updraught in the chimney, which prevents smoke from entering the room when you light the log-fire.negative pressure compensation. When the cooker hood is in use, negative pressure arises in the home since the extract airflow becomes substantially higher than the supply airflow. This function compensates the negative pressure by automatically increasing the supply airflow. Home Away switch. Should be located close to the front door. When the button is pushed, the ventilation unit switches to operation in the Away mode and this saves energy. The control panel of the Premium cooker hood. Presence detector. The sensor detects movement in the home and transmits a signal to the ventilation unit to increase the fan speed. This function is well-suited for use in premises not used around the clock, such as in schools, day nurseries, offices, etc. Humidity sensor. The sensor detects when the humidity rises and transmits a signal to the ventilation unit to increase the fan speed. It can be located in a sauna, a bathroom, a laundry room, etc. Carbon dioxide sensor. The sensor detects an increase in carbon dioxide and transmits a signal to the ventilation unit to increase the fan speed. It is suitable for use in rooms where the number of occupants varies. DDC control Modbus gateway 4

Optional equipment Optional equipment for the ventilation unit Premium extra control panel The extra control panel can also be installed, if it is desirable to control the ventilation unit from various places. The second contact of the panel can be used for interconnecting two panels. Reheating cassette The 800 W electric air heater for reheating the supply air downstream of the heat exchanger is a factory-fitted, optional item for equipment. The air heater is switched on when the temperature of the supply air is below a preset value. The heater is wired by means of quick-fit connectors. Premium control panel Reheating cassette Roof mounting frame Facilitates mounting the ventilation unit on the ceiling. Mounting frame with moisture barrier The mounting frame has a moisture barrier which prevents moisture from entering the insulation in the attic joist floor and stops the air from the loft from coming down into the rooms. Replacement filters Replacement filters The set of filters contains two class F7 fine filters and one class G3 wide-mesh filter. Roof mounting frame Mounting frame with moisture barrier 5

Optional equipment System products The ventilation unit is a part of an economical and attractive ventilation system for homes. Swegon offers a complete series of products for home ventilation. In that all the components are supplied by the same subcontractor, you are assured that they operate reliably together and this enables you to select properly sized products. This makes it possible, for instance, to control the ventilation unit from the cooker hood. Premium Swing controllable cooker hood Cooker hoods The elegant and practical cooker hoods are available in several alternative models and materials. If you do not want to connect the cooker hood to the ventilation unit, you can select a Design cooker hood and connect it to a power roof ventilator. Ceiling penetration seal for duct Provides a moisture-proof duct penetration point for supply air diffusers and extract air registers. Available in sets of 5 for size 100, 125 and 160 mm ducts. Sound attenuator Ceiling penetration seal Supply air diffusers and extract air registers 3 9 4 7 6 2 1 5 8 6 Supply air Extract air Outdoor air Exhaust air 1. Swegon CASA R120 ventilation unit 2. Mounting frame with moisture barrier 3. Exhaust air hood 4. Sound attenuator 5. ILVA controllable cooker hood 6. Power roof ventilator 7. Supply air diffuser 8. Extract air register 9. Ceiling penetration seal

Installation Suitable installation locations are a laundry room, storage space, attic etc. If the ventilation unit is located in a cold space, it should be have thermal insulation, if required. Secure the ventilation unit vertically to the wall using the wall mounting bracket supplied with the unit. The wall structure must be able to support the weight of a 78 kg ventilation unit. It is also possible to mount the unit against the ceiling with a ceiling mounting frame, available as optional equipment. Extract air Supply air Extract air from the cooker hood Exhaust air Outdoor air The unit has an extra duct connection for extract air on its upper side. The extract air from the cooker hood flows directly out via the extract air fan of the unit and does not pass the heat exchanger. The connection not used should be blanked off by a cover or an end piece for spiral ducts (not included in the supply). The extract air from the kitchen should not be extracted via the cooker hood, since this airflow bypasses the heat exchanger. How the R120 operates. Installation alternatives 1. The Premium cooker hood connected via duct to the ventilation unit The extract air from the Premium cooker hood is conveyed via a duct to an extra duct connection on the top of the ventilation unit. The ventilation unit can be controlled from the control panel of the cooker hood or, if required, also from a separate control panel. 2. Separate controllable cooker hood The extract air from the controllable cooker hood should be connected to a separate power roof ventilator. The ventilation unit is controlled from a separate control panel. The best way to control the power roof ventilator is from the cooker hood control panel. 1. A Premium cooker hood connected via duct to the ventilation unit. 2. Separate controllable cooker hood and power roof ventilator. 7

Bypass for kitchen The Swegon CASA R series ventilation units make it possible to install a so-called kitchen bypass. This is an effective way to remove cooking odours from the kitchen and ensures that it cannot return to the kitchen via other ventilation ducts. If the cooker hood outlet air duct is connected directly to the connection spigot on the ventilation unit, the extract air is conducted directly out via the unit s extract air fan, consequently the extract air never comes in contact with the heat exchanger. Adequate suction power from the cooker hood Fewer ducts and roof penetration collars Less need for servicing 3 6 4 2 1 5 1. Swegon CASA R120 ventilation unit 2. Mounting frame with moisture barrier 3. Exhaust air hood 4. Sound attenuator 5. Premium controllable cooker hood 6. Ceiling penetration seal EXHAUST AIR SUPPLY AIR COOKER HOOD AIR EXTRACTION OUTDOOR AIR EXTRACT AIR Separate extract air from kitchen R120 Boosted extract air, up to 50 l/s 8

Sizing Supply airflow Extract air flow 500 450 100 % 500 450 100 % 400 350 87 % 400 350 87 % Available pressure, Pa 300 250 200 150 100 50 81 % 76 % 71 % 67 % 63 % 60 % 57 % 54 % 50 % 46 % Available pressure, Pa 300 250 200 150 100 50 81 % 76 % 71 % 67 % 63 % 60 % 57 % 54 % 50 % 46 % 0 0 20 40 60 80 100 120 140 0 0 20 40 60 80 100 120 140 Airflow, l/s Airflow, l/s Power consumption 300 250 100 % Extract air from the cooker hood Setting in % 65 73 85 100 Airflow, l/s 28 32 39 43 87 % Total output, W 200 150 100 50 63 % 60 % 57 % 54 % 50 % 46 % 67 % 76 % 71 % 81 % Connection power R120 R120-L Connection 230 V, 50 Hz, 1.1 A 230 V, 50 Hz, 4.6 A Fans 238 W 238 W Rotor motor 10 W 10 W 0 0 20 40 60 80 100 120 140 Airflow, l/s Air heater, reheat - 800 W Total output 250 W 1050 W 9

Acoustic data Sound emitted to supply air duct Fan setting % Sound power level broken down into octave bands, L wokt, db 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz Weighted sound power level L WA, db(a) 54 67 60 55 50 48 42 36 22 54 57 67 63 57 52 51 45 39 27 56 60 67 63 58 53 52 46 41 29 57 63 67 65 60 54 53 48 43 32 58 67 71 66 61 56 55 50 45 35 60 71 72 68 62 57 56 52 46 36 61 76 74 70 64 59 57 54 48 38 63 81 75 71 65 59 57 54 48 40 64 87 77 73 67 61 59 56 50 42 65 100 78 75 69 63 60 58 52 44 67 Sound emitted to extract air duct Fan setting % Sound power level broken down into octave bands, L wokt, db 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz Weighted sound power level L WA, db(a) 54 64 46 48 43 37 33 23 8 45 57 64 48 49 45 38 34 24 9 46 60 62 58 51 46 39 35 26 11 49 63 64 61 51 48 40 36 27 13 50 67 63 63 53 49 41 38 29 15 52 71 63 63 55 50 43 40 31 17 53 76 66 66 56 52 44 41 32 19 55 81 63 66 57 54 45 42 33 20 55 87 66 68 58 55 46 43 35 22 57 100 66 68 59 55 46 43 35 22 57 Sound emitted to extract air duct of the cooker hood Fan setting % Sound power level broken down into octave bands, L wokt, db 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz Weighted sound power level L WA, db(a) 54 63-49 44 33 31 25 13 45 57 65-51 45 34 32 27 15 47 60 63 53 53 46 35 33 28 17 48 63 59 47 53 47 37 35 30 18 48 67 61 59 55 48 37 36 31 20 50 71 64 57 56 49 39 37 32 22 51 76 69 59 57 51 40 39 34 24 53 81 68 61 59 52 41 40 36 26 54 87 66 64 60 52 43 41 37 27 55 100 67 65 61 53 43 42 38 29 56 10

Sound emitted to the surroundings Fan setting % 63 Hz Sound power level broken down into octave bands, L wokt, db 125 Hz 250 Hz 500 Hz 1000 Hz Weighted sound power level L WA, db(a) Sound pressure level 10 m² sound absorption L P (10), db(a)*) 54 44 46 37 28 23 12 - - 30 26 57 46 46 38 29 24 13 - - 35 31 60 46 46 39 30 25 14 - - 35 31 63 44 47 40 30 26 14 - - 36 32 67 45 47 42 33 28 17 - - 37 33 71 44 48 43 34 29 19 10-38 34 76 46 49 44 34 29 20 11-39 35 81 47 50 45 36 32 21 12-40 36 87 49 52 46 37 33 22 14-42 38 100 51 54 48 39 34 24 15-43 39 *) Equivalent to a normally insulated room. 2000 Hz 4000 Hz 8000 Hz 11

Power connection The unit has a 230 V, 10 A mains plug connection. Total power consumption Excl. air heater for reheat: 250 W, 1.1 A Incl. air heater for reheat: 1050 W, 4.6 A Control from a Premium control panel The control panel can be placed at an optional location. It can be supplemented with e.g. an extra control panel or a Modbus gateway, if you want the ventilation unit to be controllable from several places. Control from a Premium cooker hood The supply includes two 3 m long cables with modular contacts, which are used for connecting the ventilation unit, cooker hood, control panel and the Modbus Gateway adaptor. The modular cable should be installed in a min. 20 mm conduit. Control from a Premium cooker hood Control from a Premium control panel Cable with modular connectors Cable with modular connectors Extra control panel Cable with modular connectors Mains power plug connection 230 V, 10 A Mains power plug connection 230 V, 10 A R120 Mains power plug connection 230 V, 10 A Extra control panel Premium control panel R120 Premium cooker hood Premium control via Modbus Gateway Cable with modular connectors Premium control panel, e.g. for entering settings or service work Mains power plug connection 230 V, 10 A Cooker hood (no provision for extension) Premium control panel Modbus Gateway R120 Modbus RTU 12

Example diagram 1 PREMIUM CONTROL PANEL If the installation is not fixed, the control panel can serve as a pure hand-held terminal for entering settings or carrying out service work. In this case you must make sure that the connection contact is accessible. 230 V, 10 A Modular cable Modular cable - Home-Away-Boost - 24-hour/weekly timer - Fireplace switch - Alarm 230 V, 10 A Modbus gateway Premium cooker hood Modbus RTU See separate instructions Humidity sensor CO 2 sensor/temperature sensor Presence detector 4 x 0.5 4 x 0.5 W80 EC W100 EC W130 EC W230 EC R85 EC R120 EC E.g. 6 x 0.5 Home - Away selector switch DDC (remote monitoring) - Emergency stop - Operating status/fans - Operating status/temperature Misc. Example diagram 2 PREMIUM CONTROL PANEL Modular cable Modular cable 230 V, 10 A - Home-Away-Boost - 24-hour/weekly timer - Fireplace switch - Alarm 230 V, 10 A Modbus gateway Premium cooker hood Modbus RTU See separate instructions Humidity sensor Home - Away selector switch CO 2 sensor/temperature sensor Presence detector Misc. 4 x 0.5 4 x 0.5 W80 EC W100 EC W130 EC W230 EC R85 EC R120 EC E.g. 8 x 0.5 DDC (remote monitoring) - Emergency stop - Operating status/fans - Operating status/temperature - Control of fan speed - Control of temperature When the control voltage is interrupted, the control system returns to the user mode for use by the occupants. 13

Example diagram 3 PREMIUM CONTROL PANEL - Home-Away-Boost - 24-hour/weekly timer - Fireplace switch - Alarm Humidity sensor Modular cable Negative pressure compensation 230 V, 10 A Modbus gateway 230 V, 10 A Other cooker hood (not Premium) Modbus RTU See separate instructions CO 2 sensor/temperature sensor Presence detector 4 x 0.5 4 x 0.5 W80 EC W100 EC W130 EC W230 EC R85 EC R120 EC DDC (remote monitoring) - Emergency stop - Operating status/fans - Operating status/temperature Misc. Variants Right-hand or left-hand version In order to facilitate the installation the ventilation unit is available in a right-hand (R) or left-hand (L) version. They are mirror images of one another. This way you can select a variant that offers the simplest possible system for arranging the ducting. This is important, since extra bends in the ducting increase the pressure and the fans have to overcome a heavier load. 4 K 2 2 K 4 3 1 1 3 Swegon CASA R120 L Swegon CASA R120 R Supply air 1 Extract air 2 Outdoor air 3 Exhaust air 4 Extract air from cooker hood K 14

Dimensions Swegon CASA R120 Wall mounting bracket 600 Condensate hose location 60 10 119 598 108 126 457 597 604 Swegon CASA R120 R Swegon CASA R120 L 2 5 4 4 5 2 1 3 3 1 119 299 479 Duct Connections 1 2 3 4 5 Supply air 160 Extract air 160 Outdoor air 160 Exhaust air 160 Cooker hood s exhaust air 125 Weight: 78 kg. 15

Ordering key Ventilation unit Ventilation unit Swegon CASA R120 Premium EC R right-hand version L left-hand version Ventilation unit Swegon CASA R120 Premium EC (with electric reheating) R right-hand version L left-hand version Control Premium control panel, EN, SE, FI, NO, DE, FR (incl. 20 m long modular cable) 10212RRE 10212RLE 10212RREL 10212RLEL PSP148 Optional equipment Humidity sensor 117KKH Carbon dioxide sensor 117HDL Temperature thermostat 117T Presence detector 102LT Fireplace switch 102TKC Weekly timer/24-hour timer 105A1 Boost switch with timer 105TK Modbus gateway PMB Room temperature sensor PRTG 20 m modular cable with RJ9 connector PMK20 Reheating cassette (R/L) 10212RVM Filter set, 1 pc. G3 + 2 pcs. F7 10212RSS Ceiling mounting frame (R/L) 10212KA Mounting frame with moisture barrier 10212YP Water trap UVL System products Cooker hoods Supply air diffusers and extract air registers Sound attenuator Ceiling penetration seal for duct, set of 5 pcs. 100 mm 125 mm 160 mm 102LT10 102LT12 102LT16 16