VENTILATION. Effective heat exchange and fresh air ventilation

Similar documents
VENTILATION. Effective heat exchange and simultaneous fresh air ventilation COMMERCIAL PRODUCT LINEUP

PRODUCT LINEUP VRF. For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL

20% ENERGY RECOVERY VENTILATOR SUPPRESSES INDOOR TEMPERATURE CHANGES WHILE PROVIDING FRESH AIR

Compact Design For Light Commercial Buildings. Benefit Points SMALL OFFICES HOTELS NEW SHOPS, RESTAURANTS. 1. Compact & Quiet design

FUJITSU VRF 2016/17 PRODUCT CATALOGUE VRF MULTI SPLIT VRF VENTILATION

Product Line Introduction. Karl Zhang Technical support engineer

Integrated VarIable refrigerant flow ahu/pau (r410a)

mini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS

DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE.

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

VRV IV i-series heat pump

Ducted inverter reverse cycle air conditioning

OUTDOOR AIR UNIT DTV_OAE034E_03--CHAPTER

Hitachi Air Conditioning. Engineered for tomorrow. VRF Systems Ventilation GENERAL CATALOGUE

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF

SEQUENCE OF OPERATIONS

The ultimate fresh air solution.

New rooftop series UATYQ-ABAY1 AFC2Y1 AFC3Y1. Extensive option package included in all models. ErP. years warranty. compliant 2018

PRODUCT RANGE: ROOFTOP PACKAGE

DC Inverter Smart VRF Products(R410A)

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

Fresh Air Ventilation

Fresh Air Ventilation

COMPACT AIR HANDLING UNIT. CompAir RW. Technical Brochure

recooler HP EQKR HEAT PUMP

AHU Plus. DX Air Handling Units

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

Leading edge reverse cycle air conditioning. Ducted and ceiling cassette

DUCTED AIR CONDITIONING SOLUTIONS

AIR TREATMENT. ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT

Project ID: 9217 Project name: Fuller Lake Arena Address: Fuller Lake, BC V0R 1K5 Project Type: Sports Complex / Civic Center

Daikin Inverter Ducted Systems

ELECTRICAL QUANTITY WEIGHT (LB)

Just feel well. 2017/2018 Air conditioning

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

High Efficiency, Powerful Heating and Cooling HEAT PUMP PEH-7, 8, 10 AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS. Series

DVM S Universal Communication Kit (UCK) Design Guide

Come home to a warm welcome

1. GENERAL INFORMATION

3 rd Generation of VRV. The professional solution for your professional project

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

2 &3-4 Head Multi System

DESIGN & TECHNICAL MANUAL

AIR-HANDLING UNIT (AHU) DESIGN GUIDELINE

Ultimate VRF System R410A, 50Hz

Daikin Applied UK Technically better... D-AHU Modular R. Air handling units. Compact air handling unit with heat recovery wheel

LENNOX MINI-VRF SYSTEMS. CONNECTING TECHNOLOGY WITH EXPERTISE.

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

Heat Pump Air Conditioning Systems

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

DAIKIN Air Handling Unit Modular

208/230V, 1-Phase. 208/230V, 460V 3-Phase. 208/230V, 460V 3-Phase

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

ReCooler Heat-Pump Energy efficient cooling unit for eq Air Handling Unit


Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value.

Product Launch SHRMi

Water cooled VRV IV W-series

1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA

air systems Roomtop RTC-RTH 15 to 30 - L

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

Direct Drive Truck Units. A complete line of refrigeration units for a wide variety of vehicle chassis and applications.

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C)

Inverter Wall Mounted Series

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

Heat pump & cooling unit in one

Blending Commercial and Residential. MiNi VRF

DESIGN & TECHNICAL MANUAL

January Engineering Data RXSQ24-60TAVJU. Heat Pump 208/230V / 60 Hz / 1 ph. Presales Manual DAIKIN NORTH AMERICA LLC

9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

N , Suenaga, Takatsu-ku, Kawasaki , Japan

MULTI SPLIT. Control several indoor units with one outdoor unit. Build the optimum system you desire.

360 round flow, ensuring uniform airflow distribution across the room. Independent louvre control allows each louvre to be set at the desired angle

Hi-spec Design model. Photo : LT series

DESIGN & TECHNICAL MANUAL

Variable Refrigeration Flow Systems Overview 10/11/2016

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

LG VRF Systems. Air Conditioning Technologies

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

AIR HANDLING UNITS RIS P EKO 3.0. New range - 5 sizes, 20 models! Efficient EC. E f f i c i e n c y up to 94%! E x t r e m e l y low height! fans!

Direct Drive Truck Units. A complete line of refrigeration units for a wide variety of vehicle chassis and applications.

1.0 Digital Controller

V4 Plus Heat Recovery VRF. Linda Lin Pre-sales Engineer

DESIGN & TECHNICAL MANUAL

CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

Accessories Control systems

AIR HANDLING UNITS ver B

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

Transcription:

VENTILATION Effective heat exchange and fresh air ventilation High Efficiency and low noise levels are achieved by using a highly efficient heat exchange process. A comfortable air conditioned space is achieved by conveniently selecting whether to use heat exchange or normal ventilation setting, according to the requirements of the conditioned space. 208 Energy Recovery Ventilator 210 Energy Recovery Ventilator Options 212 Outdoor Air Unit 214 for Air Handling Application 216 Freeverter for Air Handling Application 206

PRODUCT LINEUP Airflow rate (m 3 /h) 250 350 500 800 1000 1500 2000 Energy Recovery Ventilator Page 208 ERV Options Page 210 UTZ-BD025B UTZ-BD035B UTZ-BD050B UTZ-BD080B UTZ-BD100B Outdoor Air Unit Page 212 ARXH054GTAH ARXH072GTAH ARXH096GTAH Connectable Capacity class (kw) 5.0 6.3 8.0 10.0 12.5 14.0 20.0 25.0 40.0 50.0 for air handling applications Page 214 UTP-VX30A UTY-VDGX UTP-VX60A UTY-VDGX UTP-VX90A UTY-VDGX UTP-VX90A 2 UTY-VDGX Connectable Capacity class (kw) 3.5 5.2 6.8 8.5 9.4 10.0 12.5 14.0 20.3 25.0 Freeverter for air handling applications Page 216 207

VENTILATION Energy Recovery Ventilator A comfortable air conditioned space is achieved by conveniently selecting whether to use heat exchange or normal ventilation setting, according to the requirements of the conditioned space. Energy recovery ventilator units offer maximum comfort and greater energy savings. Features Adopts a highly efficient counter-flow Exhaust air Outside air Heat exchanger heat exchange element Room air Supply air Heat exchange ventilation and normal ventilation Heat exchange ventilation When a room is cooled or heated, the exhausted cooling / heating energy is recovered by heat-exchange ventilation. Normal ventilation The operation is used during periods when the room space requires no cooling or heating effect, i.e. when there is minimal temperature difference between the indoor and outdoor environments. Energy efficiency and ecology Energy consumption is dramatically reduced by using a counter-flow heat-exchange element. Air conditioning load is reduced by approximately 20%, resulting in significant energy savings. Recovers up to 77% of the heat in the outgoing air. Features of heat exchange element With the cross-flow element, air moves in a straight line across the element. With the counter-flow element, air flows through the element for a longer time (longer distance), so the heat-exchange effect remains unchanged. Other element (Cross-flow element) Fujitsu element (Counter-flow element) Quiet operation Significantly reducing low pressure loss and noise allows low-noise operation. Extended range of an external static pressure An external static pressure is improved by adopting a powerful fan motor. This allows for application in a wide variety buildings. 208

Slim shape and easier installation Counter-flow heat exchange element used for reduced noise and slimmer, more compact body shape. Height 270 mmm UTZ-BD025B Height 388 mm UTZ-BD080B/BD100B Reverse mountable direct air supply / exhaust system Adoption of straight air supply / exhaust system: Duct design is simplified because the air supply / exhaust ducts are straight. Since each unit can be mounted in reverse position, only one inspection hole is needed for two units: Two units can share one inspection hole so duct work is easier and more flexible. Room air Straight unit Supply air Inspection cover Inspection hatch Room air Reverse mounted unit Exhaust air Outside air Exhaust air Model : UTZ-BD025B / UTZ-BD035B / UTZ-BD050B / UTZ-BD080B / UTZ-BD100B UTZ-BD025B UTZ-BD035B UTZ-BD050B UTZ-BD080B UTZ-BD100B Specifications 250 m 3 /h 350 m 3 /h 500 m 3 /h 800 m 3 /h 1000 m 3 /h Model No. UTZ-BD025B UTZ-BD035B UTZ-BD050B UTZ-BD080B UTZ-BD100B Power source 220-240V, 50Hz Input power (Extra high)/high/low W 128 / 123 / 96 190 / 185 / 168 289 / 225 / 185 418 / 378 / 295 464 / 432 / 311 (Extra high)/high/low m 3 /h 250 / 250 / 190 350 / 350 / 240 500 / 500 / 440 800 / 800 / 630 1000 / 1000 / 700 I/s 69 / 69 / 52 97 / 97 / 66 138 / 138 / 122 222 / 222 / 175 277 / 277 / 194 External static pressure (Extra high)/high/low Pa 105 / 95 / 45 140 / 60 / 45 120 / 60 / 35 140 / 110 / 55 105 / 80 / 75 Temperature Exchange (Extra high)/high/low % 75 / 75 / 77 75 / 75 / 78 75 / 75 / 76 75 / 75 / 76 75 / 75 / 79 Heat Exchange Ventilation Energy Exchange (Extra high)/high/low % 63 / 63 / 65 66 / 66 / 71 62 / 62 / 64 65 / 65 / 68 65 / 65 / 70 Energy Exchange (Extra high)/high/low % 70 / 70 / 72 69 / 69 / 73 67 / 67 / 69 71 / 71 / 74 71 / 71 / 76 Sound pressure level (Extra high)/high/low db* 31.5 / 30.5 / 26.5 33 / 31 / 25.5 37.5 / 35.5 / 32.5 37.5 / 37 / 34.5 38.5 / 37.5 / 34.5 Input power (Extra high)/high/low W 128 / 123 / 96 190 / 185 / 168 289 / 225 / 185 418 / 378 / 295 464 / 432 / 311 (Extra high)/high/low m 3 /h 250 / 250 / 190 350 / 350 / 240 500 / 500 / 440 800 / 800 / 630 1000 / 1000 / 700 I/s 69 / 69 / 52 97 / 97 / 66 138 / 138 / 122 222 / 222 / 175 277 / 277 / 194 External static pressure (Extra high)/high/low Pa 105 / 95 / 45 140 / 60 / 45 120 / 60 / 35 140 / 110 / 55 105 / 80 / 75 Sound pressure level (Extra high)/high/low db* 31.5 / 30.5 / 26.5 33 / 31 / 25.5 38.5 / 38 / 32.5 37.5 / 37 / 34.5 40.5 / 39.5 / 36.5 Dimensions W D H mm 882 x 599 x 270 1050 x 804 x 317 1090 x 904 x 317 1322 x 884 x 388 1322 x 1134 x 388 Weight kg 29 49 57 71 83 Outlet duct diameter mm 150 150 200 250 250 Operation range C -10 to 40-10 to 40-10 to 40-10 to 40-10 to 40 Normal Ventilation Maximum humidity % 85 85 85 85 85 List Price 707 874 1123 1633 1851 * The noise level must be measured 1.5 m below the centre of the unit. Dimensions (Unit : mm) Maintenance space Maintenance opening UTZ-BD025B UTZ-BD035B UTZ-BD050B UTZ-BD080B UTZ-BD100B A 810 978 1018 1250 1250 B 599 804 904 884 1134 C 315 580 640 428 678 D 142 112 132 228 228 E 600 600 600 600 600 F 655 860 960 940 1190 G 19 19 19 19 19 H 270 317 317 388 388 I 135 159 159 194 194 J 159 182 182 218 218 K 882 1050 1090 1322 1322 L 414 470 470 612 612 M 95 70 127 85 85 N 219 162 210 258 258 O 144 144 194 242 242 209

NEW VENTILATION Energy Recovery Ventilator Options Features ERV RELAY This accessory will allow an Energy Recovery Ventilator unit to start & stop in unison with the connected indoor unit (There will be no control over on / off, fan speed or damper bypass) Model Name UTY-ERVRELAY1 Power source 208-240V, 50Hz, Single Phase Dimensions (H x W x D) mm Weight g TBC List Price 76 210

Hard wired Control Interface In order to use a Fujitsu hard-wired controller with the ERV units an interface is required The UTI-ERV2 interface provides the following features:- UTI-ERV2 interrface is supplied with an outside air intake duct sensor for control of the ERV bypass damper e.g. heat recovery or "free cooling" bypass mode Dry contact terminals for remote on/off e.g. from BMS Allows the use of a Fujitsu UTY-RNKY* hard wired controller which has the following features: Allows ERV fan speed selection from the remote controller Controller has an integral 7 day programmable time clock Controller has temperature selection for auto control of the damper Filter clean indicator facility Manual or Auto control of the bypass damper Please refer to the UTI-ERV installation manual for the full wiring diagram DO NOT use the above diagram this is for illustrative purposes only Description of the buttons on UTY-RNKY remote 1. 2. Start / Stop Set Temperature 3. Master Control 4. Fan Control 5. ERV on/off 6. Timer mode (clock adjust) 7. Day (day off) 8. Set Back 9. Set Time 10. Delete 11. Set 12. N/A 13. N/A 14. Filter Button 15. Operation Lamp 16. Timer & Clock Display 17. Operation Mode Display 18. Fan Speed Display 19. Operation Lock Display 20. Temperature Display 21. Function Display Delete Set Button Model Name UTI-ERV2 Power source 208-240V, 50/60Hz, Single Phase Power Consumption W 6.5 Dimensions (H x W x D) mm 67 288 211 Weight g 1,500 List Price 366 UTY-RNKY From UTI-ERV2-120 120 18 160 83 *UTY-RNKY to be ordered seperately 211

VENTILATION Outdoor Air Unit The Outdoor Air Unit efficiently processes the outdoor air for cooling heating and supplies 100% fresh air into a room. Features One VRF system can provide air conditioning and air supply at the same time. VRF system Duct Outdoor Air Unit can be connected in a same VRF*1 system as one of indoor unit series and can create fresh and comfortable air supply together from our high advanced technology. *1. Connectable VRF series: J-IIS, J-II, J-III, J-IIIL, V-III, VR-II, OAU is prohibited to connect under the ambient temperature of 40 C or higher. Outdoor Air Unit Fan Heat Exchanger Outdoor Air Unit Indoor unit Fresh Air Indoor unit Fresh Air Wired R.C. Wired R.C. Wired R.C. * Make sure the connected capacity is within the range of 50% to 100% of the outdoor unit capacity. In addition, if there are mixed connections with indoor units, make sure the Outdoor Air Unit connection capacity is 30% or less of the outdoor unit capacity. High energy savings and flexible duct design by using a DC fan motor Greatly reduces electricity consumption by adopting permanent magnet compared to when using an AC motor. Compared with AC motor, changing the speed makes it possible to respond flexibly to the external static pressure from 50 Pa to 240 Pa. Even if damper equipment is not used, static pressure can be adjusted and duct design is easy. Static pressure can be set easily using wired remote controller. DC Motor AC Motor (When external static pressure is small) Low speed High speed (Constant) 50 to 240 Pa (096 type) Damper opening small (Locally purchased) High speed High speed (Constant) (When external static pressure is large) Damper opening large (Locally purchased) Compact design Lightweight compact design at just 425 mm in height, 55 kg in weight for ARXH072 type. This unit can be installed easily even in narrow spaces. 55 kg (072 type) 1367 mm 425 mm 572 mm (ARXH072 type) 212

Various Controllers Variety of control options can be supplied, such as individual controller, central controller, and building management controller. Individual Controller Central Controller Wired Remote Controller (Touch Panel) Wired Remote Controller Simple Remote Controller Wireless Remote Controller Group Remote Controller Central Remote Controller Touch Panel Controller System Controller System Controller Lite (Software) * The temperature setting is discharged air temperature setting. The air volume is set to a constant speed. Model : ARXH054GTAH / ARXH072GTAH / ARXH096GTAH Production by order ARXH054GTAH ARXH072GTAH ARXH096GTAH Specifications Model name ARXH054GTAH ARXH072GTAH ARXH096GTAH Power source V/Ø/Hz 230/1/50 230/1/50 230/1/50 Capacity Cooling 14.0 22.4 28.0 kw Heating 8.9 13.9 17.4 Input Power Cooling/Heating W 179 292 370 m 3 /h 1,080 1,680 2,100 Static Pressure Standard (range) Pa 185 (50-185) 200 (50-200) 200 (50-240) Sound Pressure Level db (A) 42 44 47 Dimensions (H x W x D) mm 425 1,367 572 425 1,367 572 450 1,583 700 Weight kg 48 55 71 Connection Pipe Diameter (Small / Large) Inch 3/8 & 3/4 1/2 & 7/8 1/2 & 7/8 Operation Range Cooling 5 to 43 5 to 43 5 to 43 ºCDB Heating -7 to 21-7 to 21-7 to 21 Refrigerant R410A R410A R410A List Price 2480 4008 4238 Note : Specifications are based on the following conditions. Cooling : Outdoor temperature of 33 CDB / 28 CWB. Pipe length : 7.5 m Voltage : 230 [V]. Heating : Outdoor temperature of 0 CDB / -2.9 CWB. Dimensions (Unit : mm) ARXH054GTAH Main drain port Safety drain port Side view (R) Side view (L) Top view (Drain hose) Front view ARXH072GTAH ARXH096GTAH Main drain port Main drain port Safety drain port Safety drain port Side view (R) Side view (R) Side view (L) Top view Side view (L) Top view (Drain hose) (Drain hose) Front view Front view 213

VENTILATION for Air Handling Applications These kits enable other manufacturers air handling units (AHU) and fan coil units (FCU) to be incorporated into a Fujitsu VRF system or, be connected to a dedicated Fujitsu VRF outdoor unit as a 1:1 system to control outside air ventilation (AHU) or room temperature (FCU). Features Multiple temperature sensors optimally control the air handling unit or fan coil unit. AHU Thermistor When connecting to an air handling unit, the supply air temperature is controlled by the discharge sensor. Arrangement as part of a VRF system VRF system Indoor unit Transmission line FCU Thermistor When connecting to a fan coil unit, the room temperature is controlled by the return air temperature sensor. Air Handling Unit Thermistor Wired R.C. Supports a wide range of capacity classes 2 s can be connected in parallel and up to 20 HP (50 kw) large capacity units. (Separation Tube of UTP-LX180A is required.) Connectable capacity range: 5 kw to 50 kw Piping AHU or FCU (40 50 kw class) Wiring A variety of controls to match the application Central control using our VRF controllers or central management controllers Central control from on site BMS Transmission line VRF Controller Interface (Option) Modbus network (Future release) External I/O Thermistor AHU or FCU Transmission line External I/O DDC* 3rd party Controller Thermistor External I/O AHU or FCU *DDC=Direct Digital Controller 214

Functions Summary Inputs ON/OFF Setting temperature Capacity demand Heating / Cooling operation mode Fault information Outputs ON/OFF indication Fan ON/OFF indication Thermo ON/OFF indication Defrost indication Fault indication MODBUS Control Possible to control via a MODBUS enabled BMS by using optional interface. Installation Limitation Connectable VRF series: J-IIS, J-II, J-III, J-IIIL, V-III, VR-II Connectable system capacity range: 50 to 100% of the outdoor unit capacity Connectable system capacity range with indoor units: 30% or less of the outdoor unit capacity Max. wiring length from control unit to sensor positions: 15 m Max. wiring length from control unit to EEV: 10m Max. piping length between and indoor unit: 5 m Outdoor installation: (IP54 rated) and EEV unit can be installed in an outdoor environment. Connectable capacity Single connection Air Handling Unit 50% 100% of outdoor unit capacity Piping and wiring length Air Handling Unit Mixed connection Air Handling Unit Within 30% of total capacity 50% 100% of outdoor unit capacity For 2s connection (option) Separation Tube: UTP-LX180A 90 Max. piping length 10 m Max. wiring length 10 m Max. wiring length 15 m : UTY-VDGX : UTP-VX30A / UTP-VX60A / UTP-VX90A UTP-VX30A UTP-VX60A UTP-VX90A UTY-VDGX Specifications Connectable Capacity class 5.0 kw 6.3 kw 8.0 kw 10.0 kw 12.5 kw 14.0 kw 20.0 kw 25.0 kw 40.0 kw 50.0 kw Capacity Cooling 5.6 6.3 8.0 10.0 12.5 14.0 22.4 25.0 40.0 50.4 kw Heating 6.3 7.1 9.0 11.2 14.0 16.0 25.0 28.0 45.0 56.5 Control Unit UTY-VDGX Power source V/Ø/Hz 230/1/50 Dimensions (H x W x D) mm 400 400 120 List Price 780 EEV Unit UTP-VX30A UTP-VX60A UTP-VX90A UTP-VX90A x2 Connection Pipe Diameter (Liquid) 3/8 1/2 1/2 1/2 mm Dimensions (H x W x D) 160 220 90 List Price 240 240 240 480 Note: Specifications are based on the following conditions. Cooling: Indoor temperature of 27 CDB / 19 CWB, and outdoor temperature of 35 CDB / 24 CWB. Heating: Indoor temperature of 20 CDB / (15 CWB), and outdoor temperature of 7 CDB / 6 CWB. Pipe length: 7.5 m Voltage : 230 [V]. 215

VENTILATION Freeverter for Air Handling Applications Freeverter is an interface module developed for FUJITSU Split System heat pump outdoor units so that they can be used to provide cooling or heating for DX Air Handling units ((AHU's) by other manufacturers). Features By interfacing a FUJITSU heat pump to a DX coil in an air handling unit (AHU(by others)), outside air for ventilation purposes can be efficiently and cost effectively cooled and heated by a single outdoor Heat Pump unit for year round operation. The freeverter module can accept dry contact fan, heat, Cool control inputs & 0-10vDC capacity signals from site BMS systems to control the Fujitsu outdoor units (3.5kW to 25kW capacity sizes). If no BMS is available then optional duct or room controllers will need to be added for a stand alone solution. 30 control steps are available from 0% to 100% capacity The Freeverter control logic is very well protected: Automatic defrost. Automatic defrost after stop. Compressor protection. Compressor pre-heating. Auto restart after power failure. Freeverter Product Code UTY-FVI Power Supply 230vAC 50Hz 1 Phase Power Consumption 4w Current 0.015A Inputs Cool / Heat Dry Contact 20mA Inputs Cool / Heat Impedance 10Kohm 0-10vDC Coil Sensor Length 2m Dry Contact relay max Fan Out 240v, 0.3A Dry Contact relay max Error Out 240v, 0.3A Housing Colour RAL7035 Protection Rating IP66 List Price 1329 216

Heating @ Power Supply V/ Pipe Run Max R410A gas Run Amps Outdoor unit Cooling kw (1) EER Heating kw (1) COP Pipe Size -10 C kw Ph Min - Max (2) charge kg (3) clg/htg (4) List Price AOYG12LA 3.5 (0.9-4.4) 3.33 4.1 (0.9-5.7) 3.69 4.06 230V / 1ph 3-10m 3/8, 1/4 1.35 4.8 / 5.1 661.00 AOYG18LA 5.2 (0.9-5.9) 3.21 6.0 (0.9-7.5) 3.61 5.44 230V / 1ph 3-10m 1/2, 1/4 1.45 7.2 / 7.4 784.00 AOYG24LA 6.8 (0.9-8.0) 3.08 8.0 (0.9-9.1) 3.54 6.76 230V / 1ph 3-20m 5/8, 1/4 2.00 9.7 / 9.9 1,004.00 AOYG30LE 8.5 (2.8-10.0) 3.21 10.0 (2.7-11.2) 3.73 8.33 230V / 1ph 3-20m 5/8, 3/8 3.30 11.6 / 11.7 1,262.00 AOYG36LE 9.4 (2.8-11.2) 3.18 11.2 (2.7-12.7) 3.61 9.41 230V / 1ph 3-20m 5/8, 3/8 3.30 13.0 / 13.6 1,499.00 AOYG45LE 12.5 (4.5-14.0) 2.91 14.0 (5.0-16.2) 3.68 12.03 230V / 1ph 3-30m 5/8, 3/8 4.55 16.5 / 16.1 1,701.00 AOYG36LA 10.0 (4.7-11.4) 3.52 11.2 (5.0-14.0) 3.90 11.32 400V / 3ph 5-30m 5/8, 3/8 5.60 4.3 / 4.4 1,502.00 AOYG45LA 12.5 (5.0-14.0) 3.08 14.0 (5.4-16.2) 3.81 12.93 400V / 3ph 5-30m 5/8, 3/8 5.60 6.4 / 5.5 1,847.00 AOYG54LA 14.0 (5.4-16.0) 3.01 16.0 (5.8-18.0) 3.66 13.54 400V / 3ph 5-30m 5/8, 3/8 5.70 6.9 / 6.5 1,941.00 AOYA72LA 20.3 (10.8-23.5) 3.25 22.6 (12.0-26.5) 3.60 19.40 400V / 3ph 5-50m 7/8, 1/2 17.25 9.6 / 9.6 3,062.00 AOYA90LA 25.0 (11.2-28.0) 3.20 28.0 (12.5-31.5) 3.40 22.76 400V / 3ph 5-50m 7/8, 1/2 17.25 11.9 / 12.5 3,367.00 Cooling capacities based on +4 C evaporating temperature and 35 C outside ambient. Instantaneous heating capacities (excluding defrost) at +45 C condensing temperature and +7 C and -10 C outside air temperature. Operating limits: Cooling: -10 C ~ 46 C Heating: -15 C ~ 24 C AOYG12-24LA AOYG30-36LE AOYG45LE AOYG36-54LA AOYA72-90LA Stand Alone Control options If no site BMS exists then optional controls can be used to enable a stand alone solution. (available from controls or heating distributor) RLM162 Supply / Return air duct sensor RLA162 Room Sensor Controller QAC22 Outdoor Air Sensor 217