Integrated VarIable refrigerant flow ahu/pau (r410a)

Similar documents
Product Line Introduction. Karl Zhang Technical support engineer

Heat Pump Air Conditioning Systems

DC Inverter Smart VRF Products(R410A)

VENTILATION. Effective heat exchange and fresh air ventilation

Increase your flexibility.

AHU Plus. DX Air Handling Units

3 rd Generation of VRV. The professional solution for your professional project

MRVIII-C MRVIII-C. 4 way air return heat exchanger design. Two stages heat exchanger design. Double EEV design. Special Heat Exchanger Design

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

Modular Air Cooled Scroll Chillers

mini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS

MEPS COMPLIANT. Product Review OPA-RK Series. Ducted Packaged Roof Top Air Conditioners kw 137 kw. Extra Long Life Epoxy Coated Outdoor Coil

PRODUCT LINEUP VRF. For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

ELECTRICAL QUANTITY WEIGHT (LB)

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

Service Step by Step Trouble-Shooting Check-List

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP

LG VRF Systems. Air Conditioning Technologies

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

PRODUCT GUIDE

High Efficiency, Powerful Heating and Cooling HEAT PUMP PEH-7, 8, 10 AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS. Series

Single Fan MiNi VRF Apartment Ready

Ducted inverter reverse cycle air conditioning

CHAPTER 6 CONDENSING UNITS

2 &3-4 Head Multi System

Submitted to Reference Approval Construction Unit Designation Schedule #

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES

Highly Efficient,Powerful Heating and Cooling.

VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG

IT COOLING CLOSE CONTROL AIR CONDITIONERS PRECISION AIR CONDITIONERS WITH INVERTER TECHNOLOGY FOR STABLE ROOM CONDITIONS

INVERTER SCROLL. LG Electronics Distributed by. Copyright 2017 LG Electronics. All rights reserved.

Indirect Evaporative Air Conditioning FACTORY INSTALLATION (CW-160)

Inverter Wall Mounted Series

SUBMITTAL DATA: PEAD-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7

EXPAIR. Use. Precision air handling cabinets. Reducted footprint Dual-wall construction

INVERTER SCROLL INVERTER SCROLL INVERTER SCROLL. LG Electronics Distributed by

Compact Design For Light Commercial Buildings. Benefit Points SMALL OFFICES HOTELS NEW SHOPS, RESTAURANTS. 1. Compact & Quiet design

TECHNICAL DATA & SERVICE MANUAL

EN aquatech.piovan.com

PAC BT LOW TEMPERATURE HEAT PUMP

> Refrigerant R-410A. Uniflair LE TDER-TUER kW. Energy-saving units with backward-curved fans. Perimeter cooling for medium/large data center

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

TECHNICAL DATA & SERVICE MANUAL

PRODUCT RANGE: ROOFTOP PACKAGE

TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA

SUBMITTAL DATA: PEAD-A12AA7 & PUZ-A12NKA7(-BS) 12,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A12NKA7

2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating

Midea Ducted and Cassette Split Systems. Year round comfort, all around the house.

Product Launch SHRMi

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

Technical Data OPA RKTBG-P. Ducted Three Phase Packaged Air Conditioners. 47 kw 96 kw

SUBMITTAL DATA: PVA-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Blending Commercial and Residential. MiNi VRF

ROOFTOP PACKAGED AIR CONDITIONERS

Series 9. Commissioning Checklist. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.

FUJITSU VRF 2016/17 PRODUCT CATALOGUE VRF MULTI SPLIT VRF VENTILATION

Daikin Applied UK Technically better... D-AHU Modular R. Air handling units. Compact air handling unit with heat recovery wheel

HVAC Mandatory Provisions Part II, Page 1

VRV IV i-series heat pump

NFZP Variable Refrigerant Flow Guide Specification

PANASONIC INDUSTRIAL VRF SYSTEMS

Aircooled Units. AirPLUS Aircooled scroll chiller. Freecooling options: liquid control. Freecooling options: fans control. Noise \\ Efficiency options

SUBMITTAL DATA: PCA-A24KA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H CEILING-SUSPENDED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A24NHA7

Series 8. Guide Specification 60 Hz. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

LG AIR CONDITIONERS Ducted Split System. Quiet & Comfortable with LG HVAC.

COMPACT AIR HANDLING UNIT. CompAir RW. Technical Brochure

SUBMITTAL DATA: PEAD-A30AA7 & PUZ-A30NHA7(-BS) 30,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A30NHA7

ACMVTECH HIGH EFFICIENCY UNITARY AHU

Inverter Ducted Air Conditioners

SUBMITTAL DATA: PVA-A36AA7 & PUZ-HA36NHA5 36,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference:

Air Conditioning. Air Conditioning. VRF systems

HVS, Hydro Variable System


Launching of new SET-FREE Outdoor Units - RAS-FSXN1E Series (8-54HP)-

Компрессорно-конденсаторные агрегаты. Chiller. AQH DCI 20 to 30. Air Cooled Water Inverter Heat Pump Engineering Data Manual. 20 to 30 kw.

SUBMITTAL AG015KSVAJH/AA Samsung DVM Heat Pump Chiller. Submitted to Reference Approval Construction Unit Designation Schedule #

Air Conditioning System

Technical Data OPA 294, 340, 370. Ducted Three Phase Packaged Air Conditioners kw 34.0 kw 39.1 kw. Twin System Enables Staging

Indirect Evaporative Air Conditioning

FLATAIR. E r P APPLICATION GUIDE kw HORIZONTAL PACKAGED AIR CONDITIONER. Cooling capacity : 6-34 kw. Heating capacity : 6-29 kw

Hitachi Air Conditioning. Engineered for tomorrow. VRF Systems Ventilation GENERAL CATALOGUE

SUBMITTAL DATA: PEAD-A24AA7 & PUY-A24NHA7(-BS) 24,000 BTU/H HORIZONTAL-DUCTED AIR-CONDITIONING SYSTEM. Job Name: System Reference:

A more comfortable, safe and sustainable world

SINGLE. Technical Data Book. PAC for Europe (R410A, 50Hz, HP) Model : AC***KNPDEH/EU AC***KXAD*H/EU

Water cooled VRV IV W-series

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

Air Cooled Scroll Chiller

Flexible & Innovative. Cooling Solutions

General Catalogue. FORM SSI - G.C (94)

Compact Horizontal Air-Air Heat Pump Model RTH 07L to 30L. Technical information. Ref.: N

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd

Air conditioners, heating & cooling. for large spaces. air to air heat pumps. FDQ-B

SUBMITTAL DATA: PVA-A36AA7 & PUY-A36NKA7(-BS) 36,000 BTU/H AIR HANDLER AIR-CONDITIONING SYSTEM. Job Name: System Reference: Outdoor Unit: PUY-A36NKA7

Leading edge reverse cycle air conditioning. Ducted and ceiling cassette

Transcription:

Integrated Variable Refrigerant Flow AHU/PAU (R410A)

CONTENTS Features of VRF AHU/PAU 2 WELAIRE i-gt Concept 9 VRF Outdoor Unit Performance Data 10 Drawings & Performance Data 12 Dimensions 13 Notes 14

Features of VRF AHU/PAU Designing of air conditioning system is simple, no water pump, no cooling tower and no cooling / chilled water piping Simple control system, built-in controls for VRF outdoor unit plus field installed LMCP for AHU/PAU Integrated package with VRF system Easy installation and maintenance Simple cable and refrigerant piping connection Max 224kW (80HP) cooling capacity Built-in backup, interlock and heat pump operation Long pipe run available for greater design flexibility Excellent full load COP for VRF outdoor unit (10HP) is 3.6, 50% COP is 4.3 Custom design of AHU/PAU arrangement to improve IAQ Flexible Design Exhaust Air Fan Heat Wheel or Heat Pipe (Optional) Filter Supply Air Fan VRF AHU/PAU EX OA EEV Control Unit RA SA Filter Humidifier (Optional) Re-heat DX Coil (Optional) A pair of Refrigerant Tube Variable Refrigerant Flow Outdoor Unit Supply Air Return Air Service Zone DX Cooling Coil Variable Refrigerant Flow Outdoor Unit 2

Simple Installation Compare VRF AHU to chiller plant system VRF AHU/PAU system PAU PAU Chiller system Pump Machine Room Chiller Water Tank Simple Design Easy Installation Easy Maintenance Low Running Cost System Integration VRF AHU/PAU Chiller System Better Fresh Air Treatment Compare Custom made VRF PAU to VRF Conventional Fresh Air Pre-treated Unit VRF PAU system Traditional VRF System for Fresh Air Up to 6,000 l/s or even more Large cooling capacity (up to 80HP) Large external static pressure provided (up to 1,800Pa) Lots of IAQ options (Eg. dehumidifier, UV light, PCO, Heat pipe or heat wheel) Small air flow rate (Max. 1800l/s) Small cooling capacity (Max. 20HP) Limited external static pressure (Max. 150Pa) No space to install IAQ components 3

Excellent Energy Saving Compare VRF AHU to Traditional DX AHU COP 5.0 4.0 3.0 2.0 1.0 VRF Outdoor (10HP) Outdoor with 2 scroll compressor (10HP) with "ON/OFF" control ENERGY ENERGY Energy Saving SAVING ENERGY SAVING SAVING ENERGY SAVING Custom Design 0 100% Part Load (50%) Load % Easy Installation & Maintenance Comfort Temperature Control Compare VRF AHU to Traditional DX AHU - Preventive of temperature hunting Zone Temperature Temp. Supply air temperature is closer to setpoint Zone temperature is kept tightly near setpoint at all times by continuous load-matching operation. Zone Temperature Temp. Supply air temperature will be colder than needed due to excess capacity Zone setpoint is maintained by on-off cycling Setpoint With VRF compressor Time Setpoint With Scroll compressor Time Post-cooling unit - Improve the existing chiller plant NEW 12 C 60mm thick double skin casing DX Cooling Coil Duct 16 C AHU OLD Post-Cooling Section or Heat mode is standard provision for heating or dehumidifying Chiller JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ r Existing chiller system with insufficient cooling capacity 4

Control System Compare VRF AHU to Traditional DX system - Interlock function When AHU started operation, it activates PAU to run automatically with simple wiring connection - Duty and Standby function If the duty AHU have fault, the standby AHU will be cut-in automatically in 30 seconds AHU "ON" Automatic Mode PAU "ON" Alarm occured (Duty Unit) Duty & Standby Mode Unit "ON" (Standby unit) AHU/PAU Timer wired remote controller -Function ON/OFF - Mode setting - Temperature setting (AHU only) - Weekly program - Alarm history NEW System Controller Individual control is possible for Max. 32 AHUs. Control of 32 AHUs / PAUs individually into 4 zones. (One zone can have up to 8 units) Control is possible for ON/OFF, operation mode, operation monitoring, alarm monitoring, remote controller local operation prohibition, etc Serial Interface for LonWorks Network LonWorks Interface Board This interfaces is a communication converter for connecting LonWorks to the control network. From the host connected to LonWorks, basic settings of status monitoring is possible for up to 32 no. of AHU/PAU. 5

Simple Wiring Requirement LonWorks Interface System Controller (Max. 64nos. AHU/PAU) LON LonWorks Communication Line Center Control Device (Field Supply) System Overview B K C A A J G F H I E D A : AHU kit controller box (with control PCB) B : AHU unit C : VRF outdoor unit D : Gas piping (field supplied) E : Liquid piping (field supplied) F : Electronic expansion valve G : Thermistor for gas pipe H : Thermistor for liquid pipe I : Thermistor for suction air J : Thermistor for discharge air K : Fan local control panel (optional) Flexible Refrigerant piping design Level difference between PAU/AHU & outdoor unit 50M (Outdoor unit above) 40M (Outdoor unit below) Equivalent tubing length available up to 120M 6

Optional - EC Plug Fan Transformation of Power Comparison level for η e(s) P o Features of EC Plug Fan - Compact design - Integrated assembly - Built in control - Infinitely variable speed settings - Control signal 0-10 V DC and MODBUS - Compatible with existing BMS - High energy saving potential Maintenance Aspect between Centrifugal Fan & EC Plug Fan Centrifugal Fan EC Plug Fan Fan Bearing Regular greasing None Fan Shaft Potential breakage None Belt Alignment, wear & tear None Pulley Alignment None 7

Other Features A. Operating Range - Cooling & Heat pump mode Heating operation range: Extended heating operation range enables heating even when the outdoor temperature is as low as -25 C. Using a wired remote control, indoor heating temperature range can be set from 16 C to 30 C*. Cooling operation range: -10 C DB to +52 C DB * Depending on the type of remote controller Outside air temperature ( C WB) -25-20 -15-10 -5 0 5 10 15 18 Outside air temperature ( C DB) -10-5 0 5 10 15 20 25 30 35 40 52 B. Extended compressor life by uniform compressor operation time The total run-time of compressors are monitored by a built-in microcomputer, which ensures that operation times of all compressors within the same refrigerant circuit are balanced. Compressors with histories showing shorter run times are selected first, ensuring equal wear and tear across all units and extended the working life of the system. System example A,C : DC inverter compressor B,D : Constant speed compressor Load Load increase increase increase A B C D A B C D A B C D A B C D Load * Depending on accumulated operation time of each compressor * Compressor priority has possibility to be changed (e.g) Case1: AACABAD, Case2: CAAADAB, Case3: AACADAB, Case 4: CAAABAD * Also other cases available C. Automatic backup operation in the case of compressor failure or outdoor unit malfuction (Except for single unit installation) Even if fan motor or sensor fail Even if a whole outdoor unit fails Even if a compressor in a single system fails Backup operation allows uninterrupted cooling or heating to continue whist waiting for service. Users should contact their authorized service centre as soon as fault occurs. X X X X NEW function The other outdoor unit can keep running The other compressor can keep running Automatic backup operation. 8

CONCEPT Innovative Green & Technology Solution VRF Dual Coil (CHW+DX) Package Air Handling Unit Internal lining EC plug fan DX cooling coil Chilled water coil Slim Type VRF Dual Coil (CHW+DX) Package Air Handling Unit (Slim VDC AHU) Y Slim VDC AHUF Features of Dual coil design - Back-up function - Post cooling function - Dehumidity function - Light-load function Filter section (Optional) EC Plug Fan (Multi-fans for Water Coil standby/duty C/W 2-way function) valve DX Coil C/W variable flow electrical expansion valve Height in mm =650 - mini shop - Server room Length in mm = 1450(+250) Width in mm = 900 9

VRF Outdoor Unit Performance Data (Standard Series) HP 10 20 30 40 50 60 70 80 Model Name U-10ME2H7 U-10ME2H7 Power Supply Cooling Capacity 380 / 400 / 415V-3-phase / 50Hz ; 380 / 400V / 3-phase / 60Hz kw 28 56 85 113 140 168 196 224 BTU/h 95,600 191,100 290,100 385,700 477,800 573,400 668,900 764,500 COP-Cooling W/W 5.03 3.76 4.31 3.74 4.09 3.76 3.90 3.76 Height mm 1,842 1,842 1,842 1,842 1,842 1,842 1,842 1,842 Dimension Width mm 770 1,540 2,420 3,140 4,020 4,740 5,570 6,340 Depth mm 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000 Net Weight kg 210 375 630 750 1,005 1,125 1,335 1,500 Electrical Ratings- Cooling A 9.6/ 9.1/ 8.8 24.6/ 23.4/ 22.5 33.6/ 31.9/ 30.8 49.9/ 47.4/ 45.7 57.7/ 54.8/ 52.9 73.8/ 70.1/ 67.6 84.0/ 79.8/ 76.9 98.4/ 93.5/ 90.1 Power Input kw 5.57 14.90 19.70 30.20 34.20 44.70 50.30 59.6 Starting Current A 1 2 4 4 6 6 7 8 Airflow Rate m 3 /h 13,440 24,300 27,840 48,600 52,140 72,900 86,340 97,200 Refrigerant Amount at shipping kg 5.6 9.5 16.6 19.0 26.1 28.5 34.1 38.0 External Static Pressure Pa 80 80 80 80 80 80 80 80 Piping Connections Ambient Temperature Operation Range Sound Pressure Level Normal Mode Sound Power Level Normal mode Gas Pipe mm Ø22.22 Ø28.58 Ø31.75 Ø38.10 Ø38.10 Ø38.10 Ø41.28 Ø44.45 Liquid Pipe mm Ø9.52 Ø15.88 Ø19.05 Ø19.05 Ø19.05 Ø19.05 Ø22.22 Ø22.22 Balance mm Pipe Ø6.35 Ø6.35 Ø6.35 Ø6.35 Ø6.35 Ø6.35 Ø6.35 Ø6.35 Cooling : -10 C (DB)~+52 C (DB), Heating: -25 C (WB)~+18 C (WB) db(a) 56.0 59.0 63.0 62.0 64.5 64.0 64.5 65.0 db 77.0 80.0 84.0 83.0 85.5 85.0 85.5 86.0 10

VRF Outdoor Unit Performance Data (High Efficiency Series) HP 10 U-10ME2H7 20 HE 30 U-30ME2H7 40 U-40ME2H7HE 50 U-50ME2H7HE 60 U-60ME2H7HE Model Name U-10ME2H7 U-10ME2H7 U-10ME2H7 U-12ME2H7 U-12ME2H7 U-10ME2H7 U-12ME2H7 U-12ME2H7 U-12ME2H7 Power Supply Cooling Capacity 380 / 400 / 415V-3-phase / 50Hz ; 380 / 400V / 3-phase / 60Hz kw 28 56 85 113 140 168 BTU/h 95,600 191,100 290,100 385,700 477,800 573,400 COP-Cooling W/W 5.03 5.05 4.31 4.45 4.58 4.24 Height mm 1,842 1,842 1,842 1,842 1,842 1,842 Dimension Width mm 770 1,600 2,420 3,660 4,490 4,900 Depth mm 1,000 1,000 1,000 1,000 1,000 1,000 Net Weight kg 210 420 630 855 1,065 1,215 Electrical Ratings- Cooling A 9.6/9.1/8.8 19.2/18.2/17.5 33.6/31.9/30.8 42.4/40.3/38.8 51.7/49.1/47.3 66.9/63.5/61.2 Power Input kw 5.57 11.10 19.70 25.40 30.60 39.60 Starting Current A 1 2 4 4 5 7 Airflow Rate m 3 /h 13,440 26,880 27,840 41,760 55,200 55,680 Refrigerant Amount at shipping External Static Pressure Gas Pipe Piping Connections Liquid Pipe Balance Pipe Ambient Temperature Operation Range Sound Pressure Level Normal Mode Sound Power Level Normal mode kg 5.6 11.2 16.6 24.9 30.5 33.2 Pa 80 80 80 80 80 80 mm Ø22.22 Ø28.58 Ø31.75 Ø38.10 Ø38.10 Ø38.10 mm Ø9.52 Ø15.88 Ø19.05 Ø19.05 Ø19.05 Ø19.05 mm Ø6.35 Ø6.35 Ø6.35 Ø6.35 Ø6.35 Ø6.35 Cooling : -10 C (DB)~+46 C (DB), Heating: -25 C (WB)~+15 C (WB) db(a) 53.0 59.0 63.0 63.5 64.5 66.5 db 74.0 80.0 84.0 84.5 85.5 87.5 11

Drawings H W L Performance Data AHU Performance Data AHU Model No. VRF Outdoor Model No. AHU Air flow rate Standard Unit Dimensions On Coil Off Coil System Cooling Height Width Length DB/RH DB Capacity m 3 /s mm mm mm C/% C kw A1-1170H-1050W U-10ME2H7 1.49 1,210 1,050 1,595 25/55 12.5 28 A1-1450H-1350W 2.90 1,550 1,350 1,595 25/55 12.5 56 A1-1770H-1650W 4.47 1,870 1,500 1,595 25/55 12.5 85 A1-1770H-1950W 5.92 1,870 1,950 1,900 25/55 12.5 113 A1-1930H-2250W 7.45 2,030 2,250 2,205 25/55 12.5 140 A1-2250H-2250W 8.94 2,250 2,250 2,205 25/55 12.5 168 PAU Performance Data PAU Model No. VRF Outdoor Model No. AHU Air flow rate Standard Unit Dimensions On Coil Off Coil System Cooling Height Width Length DB/RH DB Capacity m 3 /s mm mm mm C/% C kw A1-830H-1050W U-10ME2H7 0.50 950 985 1,595 35/70 15 28 A1-850H-1050W 1.00 950 985 1,595 35/70 15 56 A1-1170H-1050W 1.50 1,430 985 1,595 35/70 15 85 A1-1170H-1350W 2.00 1,430 1,290 1,595 35/70 15 113 A1-1330H-1350W 2.50 2,030 1,290 1,900 35/70 15 140 A1-1330H-1650W 3.00 2,030 1,595 2,205 35/70 15 168 Remarks: 1. Height does not include the unit base 100mm* 2. Standard length include coil and fan, external mounted per filter is 50mm** 3. Specifications are subjected to change without prior notice. 12

Dimensions (Standard Series) 10 HP U-10ME2H7 Installation anchor hole 8-15x21 elongated holes Air intake Air Outlet According to the installation site, you may choose the setting positionin the depth direction of the anchor bolt from A, B or C. A: (Installation hole pitch) For removing tube forward B: (Installation hole pitch) For removing tube downward C: (Installation hole pitch) 1000 Air intake Air intake A:964 953 1842 15 740 770 C:730 B: 730 18 Top View Front View 14-16 HP 1000 Air intake Installation anchor hole 8-15x21 elongated holes Air intake Air intake A:964 1842 953 Air Outlet According to the installation site, you may choose the setting positionin the depth direction of the anchor bolt from A, B or C. A: (Installation hole pitch) For removing tube forward B: (Installation hole pitch) For removing tube downward C: (Installation hole pitch) 15 1150 1180 C:730 B: 730 18 Top View Front View 20 HP Air Outlet According to the installation site, you may choose the setting position in the depth direction of the anchor bolt from A, B or C. 1000 Air intake Installation anchor hole 8-15x21 elongated holes Air intake Air intake Air intake 740 A:964 1842 953 A: (Installation hole pitch) For removing tube forward B: (Installation hole pitch) For removing tube downward C: (Installation hole pitch) 15 1510 1540 C:730 B:730 18 Top View Front View Unit in mm 13

Dimensions (High Efficiency Series) 10 HP U-10ME2H7 According to the installation site, you may choose the setting position in the depth direction of the anchor bolt from A, B or C. A (Installation hole pitch) For removing tube forward B (Installation hole pitch) For removing the downward C (Installation hole pitch) Top view Installation anchor hole, 8-15x21 elongated holes Air Intake Front view Air outlet 1000 B:730 A:964 Air Intake C:730 Air Intake 15 740 770 18 1842 953 12/14/16 HP U-12ME2H7 According to the installation site, you may choose the setting position in the depth direction of the anchor bolt from A, B or C. A (Installation hole pitch) For removing tube forward B (Installation hole pitch) For removing the downward Air outlet C (Installation hole pitch) Installation anchor hole, 8-15x21 elongated holes Air Intake Air Intake 1000 B:730 A:964 C:730 Air Intake 1842 953 15 1150 1180 18 Top view Front view Unit in mm 14

SAIVER S.R.L Via M. da Besozzo, 16 20052 Monza (Milan) Italy. Tel : +39. 039. 282 831 Fax : +39. 039. 202 5668 E-mail : info@saiver.com Website: www.saiver.com SRPC-PDFCE-VRFAHUPAU-Italy-2018.05