Fitting & Commissioning Instructions. EcoBlue Combi and System Range. Outdoor Sensor Kit. Kit Part No (System) Kit Part No.

Similar documents
Multifit. Installation & Commissioning Instructions

12.0 Servicing. Electrode Position Fig Annual Servicing Inspection (Cont) 4 ±0.5

Installation & User s Instructions

Baxi Combi 133 HE Plus Baxi Combi 100 HE Plus Baxi Combi 80 HE Plus. User s Operating Instructions

Baxi Megaflo System HE IE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Boiler

Combi Eco Elite Range. User s Guide and Important Warranty Information

User Guide. EcoBlue Advance Heat Gas Fired Wall Mounted Condensing Boiler

Performa 24 Eco HE. User Guide and Important Warranty Information. Condensing Combination Boiler

Baxi Combi 105 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Boiler

Baxi System 100 HE Plus. User s Operating Instructions. Wall Mounted Powered Flue Condensing Gas Fired Central Heating Boiler

User Guide and Important Warranty Information. Suprima HE Range. Condensing Central Heating Boiler. You can rely on

User Guide and Important Warranty Information. Promax System HE Plus A Range. Condensing System Boiler

User Guide. Promax SL Condensing Central Heating Boiler

User s Operation Instructions & Important Warranty Information. High-efficiency wall-hung boilers Baxi Avanta Heat Only 15h - 18h - 24h - 30h

User s Operation Instructions & Important Warranty Information

Installation guide. Wireless room thermostat with hot water control (DHW & single zone CH)

User Guide. Main Eco Elite Combi Condensing Central Heating Boiler

User Guide Combi. Condensing Combination Boiler

Baxi Maxflow Combi FS

Baxi Bermuda Inset 3 Super

User Guide. Duo-tec Combi LPG. Gas Fired Wall Mounted Condensing Combination Boiler

User Guide. Assure Heat Condensing Central Heating Boiler

Sirius FS. Working towards a cleaner future

User Guide. EcoBlue System Gas Fired Wall Mounted Condensing System Boiler

Baxi Maxflow Combi WM

User Guide. Gold Combi Condensing Combination Boiler

ferroli Boiler Replacement Maxima 35C- Modena HE

User Guide. Platinum Combi Gas Fired Wall Mounted Condensing Combination Boiler

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Grant Aerona³. Air to Water High Efficiency Heat Pump Range. User Instructions

Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier.

Baxi Bermuda BBU HE condensate pipe installation. B/BBUCondensate/0710/V1

User Guide. Promax Store 24. Condensing Boiler with Integrated Hot Water Storage

RT021 User and Installation Instructions

Installation & Service Instructions. Gold FSB 30 HE. Floor Standing Condensing Boiler. You can rely on

USER GUIDE Wireless room thermostat with hot water control (DHW & single zone CH)

Baxi Bahama 100. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

DIGISTAT PROGRAMMABLE 24 HOUR ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat.

Installation and Service Manual. Heat Condensing Central Heating Boiler

Avanta 24c - 28c - 35c - 39c 18s - 24s - 30s

Avanta 12v - 15v - 18v - 24v - 30v

This is a Wall Mounted Powered Flue Condensing Combination Boiler Gas Fired Central Heating Unit.

User Guide and Important Warranty Information. Suprima HE. Condensing Central Heating Boiler. Please read this document and keep it safe.

DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat

Installation & Servicing Instructions

A homeowner s guide to the Baxi Neta-tec Combi

Megaflo 2 System Compact GA Range. Installation & Servicing Instructions. Gas Fired Wall Mounted Condensing System Boiler

Baxi Combi 80Eco. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

Powermax HE 85, 115 & 150 Litre Condensing Boilers with Integrated Hot Water Storage

This is a Wall Mounted Powered Flue Condensing Combination Boiler Gas Fired Central Heating Unit.

Installation & Service Instructions. Promax SL Range. Supplied by HeatingSpares247.com. Condensing Central Heating Boiler.

Installation & Service Instructions. Promax SL Range. Condensing Central Heating Boiler. You can rely on

EcoBlue Combi Installation and Service Manual. Gas Fired Wall Mounted Condensing Combination Boiler. Model Range (09/14)

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

Performa 24. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

Unvented Electric Water Heater 10/15 litre Undersink

Installation and Servicing Instructions. Alpha FlowSmart

Performa System 12e, 18e, 24e & 28e

This is a Wall Mounted Powered Flue Condensing Combination Boiler Gas Fired Central Heating Unit.

ESRTD2 Electronic Room Thermostat, with LCD Display

heat interface units A BOILER WITHOUT A FLAME

Osprey 2 CFL

DOMESTIC HOT WATER Follow operational sequence

ES3247B. 3 Channel Programmer. User and Installation Instructions

SINGLE-CHANNEL PROGRAMMER FITTING AND OPERATING INSTRUCTIONS

Osprey 2 CFL

Baxi Combi 80 Maxflue

MULTIPOINT BF Gas Fired Balanced Flue Water Heater

User Guide and Important Warranty Information Condensing Central Heating Boiler

British Gas 330+ High Efficiency Condensing Boiler. Instructions for Use. To b e l e f t w i t h t h e u s e r. British Gas Service Tel:

Installation & User Instructions

Installation and Service Manual. Gold Heat Condensing Central Heating Boiler

Performa 24 Eco HE. Installation & Service Instructions. Condensing Combination Boiler

Users Manual. Gas wall hung Boiler condensing Buderus /S. Please read thoroughly before operating the unit

System Installation. multi-zone heating

Mexico: The Floor Standing Gas Boiler

User start guide Connected wireless room thermostat Logic Combi C / Vogue Gen 2 Combi Logic Max Combi C / Vogue Max Combi Vogue Combi C / Logic Combi

Installation and Instructions for Use Outdoor Sensor

G a

Electronic Dual Cylinder Thermostat Installation Instructions

Instructions for Use Installation and Servicing

CM921 - User Guide 1 day Wireless Programmable Room Thermostat with LoT technology

Alpha CombiMax 350 and 600

Baxi Bermuda Inset 3 Super

DT90 DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

Installation & Service Manual Remeha Avanta Range. 24c 28c 35c 39c 18s 24s 30s

Baxi Combi 130 HE. Gas Fired Wall Mounted Condensing Combination Boiler. Installation and Servicing Instructions

Mikrofill Ethos Condensing combination boiler. Maintenance Instructions 24cc

Kills bills. How Vaillant technologies reduce home heating bills

MAINTENANCE AND SERVICE GUIDE

PLEASE LEAVE THIS INSTRUCTION WITH THE USER ECOMFORT PLUS 25 HE. User instructions

Installation and Service Manual. Promax SL Condensing Central Heating Boiler

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

MULTIPOINT FF Room Sealed Fan-Assisted Water Heater

Fusion 200, 300 & 500

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

TEMPRA. Wall Mounted Fan Flue System boiler. Wall mounted fanned flue boiler INSTALLATION AND USE INSTRUCTIONS. Appr. nr. B A - CE 0063 AQ 2150

Thermostat install guide

Installation and Service Manual. Promax System Condensing System Boiler

Transcription:

United Kingdom en Fitting & Commissioning Instructions Outdoor Sensor Kit EcoBlue Combi and System Range Kit Part No. 7214286 (System) Kit Part No. 7213356 (Combi) These instructions should be read in conjunction with the Boiler Installation and Service Instructions. Please leave with the user when completed.

Contents Section Page 1.0 Legislation 2 2.0 Introduction 3 3.0 Contents of pack 3 4.0 Positioning the 3 5.0 Positioning the relay box 3 (system boilers only) 6.0 Connecting the relay box 4 (system boilers only) 7.0 Connecting the 5 8.0 Setting the parameters for the 5 9.0 Operating instructions with 6 10.0 Fault finding 7 1.0 Legislation TES: This kit is suitable only for installation in GB and IE and should be installed in accordance with the rules in force. In GB, the installation must be carried out by a Gas Safe Registered Installer. It must be carried out in accordance with the relevant requirements of the: Gas Safety (Installation & Use) Regulations. The appropriate Building Regulations either The Building Regulations,The Building Regulations (Scotland), Building Regulations (Northern Ireland). The Water Fittings Regulations or Water Byelaws in Scotland. The Current I.E.E.Wiring Regulations. Where no specific instructions are given, reference should be made to the relevant British Standard Code of Practice. In IE, the installation must be carried out by a competent Person and installed in accordance with the current edition of I.S. 813 'Domestic Gas Installations', the current Building Regulations and reference should be made to the current ETCI rules for electrical installation. 2 EcoBlue Accessories 7213361-1 (05/14)

2.0 Introduction The installation of this kit permits the customer to gain the efficiency benefits of outdoor weather temperature compensation control. The addition of anything that may interfere with the normal operation of the appliance without the express written permission from the manufacture could invalidate this kit and the appliance warranty. In GB this could also infringe the Gas Safety (Installation and use) Regulations. This kit is only suitable for use with the Baxi EcoBlue Range ONLY. This kit is suitable for use with S-Plan heating systems ONLY. 3.0 Contents of Pack Description Quantity Relay Box Outdoor Sensor Instructions (this document) 1 Outdoor sensor 1 Relay box (Only required for System Boilers) 1 N 4.0 Positioning the Outdoor Sensor 1. The Sensor must be fixed to an external wall surface of the property it is serving. The wall must face towards the north or west. W E X TE: DO T position it on a south facing wall in direct sunlight! North 1/2 H 2.5m Min Fig. 1 H 230V connections Ø 4-8mm cable West Low voltage connections Ø 3-6.5mm cable S X 2. The Sensor should be approximately half the height of the living space of the property, and a minimum of 2.5m above ground level. 3. It must be positioned away from any sources of heat or cooling (e.g. flue terminal) to ensure accurate operation. Siting the Sensor above doors and windows, adjacent to vents and close to eaves should be avoided. 4. Consider also how to route the cable from the sensor to the boiler. Wall mounting point 5.0 Positioning the Relay Box (only required for system boiler) 72mm 1. Mount the Relay Box in a convenient location between the S-Plan wiring centre and the boiler, using the mounting points shown in Fig. 2. 112mm Fig. 2 TE: When fitted in a bathroom, the relay box should not be fitted in Zones 0 or 1 as indicated in the current IEE Wiring Regulations. 7213361-1 (05/14) EcoBlue Accessories 3

1 2 3 4 Outdoor Sensor Kit L N DHW cylinder thermostat 1 C S-plan wiring centre Programmer Fig. 3 DHW ON Relay Box Outdoor sensor Boiler Boiler low voltage M2 terminals 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 br Case Front Panel Locating Lug bl br bl br 1 2 3 4 5 6 bk bl (Note: For clarity only, the connections relevant to the application are shown for the system wiring) gr gr 6.0 Connecting the Relay Box (only required for system boiler) Ensure the boiler and system wiring is isolated from the mains electrical supply. 1. Using a cable of 4-8mm overall diameter, connect the 230V connections between the S-Plan wiring centre and the Outdoor Sensor Relay Box via the large cable retaining gland. See Fig. 3. 2. Connect the thermostat output of the DHW cylinder on the wiring centre to terminal 1 of the Outdoor Sensor Relay Box. 3. Connect the neutral connector on the S-Plan wiring centre to terminal 2 of the Outdoor Sensor Relay Box. 4. Using a cable of 3-6.5mm overall diameter, connect the low voltage connections 5 & 6 in the relay box via the small gland. See Fig. 3. and route this cable to the boiler. TE: Do not route both the low voltage andmains voltage cables through the same gland. 5. Undo the securing screws and lift the case front panel off the boiler and hinge the control box downwards, Fig. 4. 6. Disengage the securing tabs and open the boiler terminal block cover, Fig. 5. 7. Remove one of the appliance blanking grommets at the base of the boiler (Fig. 6), pierce the diaphragm and insert the wires from the relay box, leaving sufficient slack in the wires to allow the control box to be hinged fully open. Refit the grommet. 8. Connect the cable from the relay box to terminals 9 & 10 of the M2 terminal block, See Figs. 6 & 7. 9. Ensure that the relay box cable grommets are tightened to ensure the cables are securely retained. 10. Refit the lid onto the relay box. Case Front Panel Securing Screws Fig. 4 Wiring Grommets Fig. 5 Standard Boiler Boiler Low Voltage M2 Terminal Block Relay Box 5 6 7 8 9 10 Compact Boiler Fig. 6 Wiring Grommets Fig. 7 4 EcoBlue Accessories 7213361-1 (05/14)

7.0 Connecting the Outdoor Sensor Boiler Low Voltage M2 Terminal Block Sensor 1 2 3 4 5 6 7 8 9 10 1. Remove one of the appliance blanking grommets at the base of the boiler (Fig. 6), pierce the diaphragm and insert the wires from the Outdoor Sensor. 2. Leave sufficient slack in the wires to allow the Control Box to be hinged fully open. Refit the grommet. 3. Connect the wires from the Outdoor Sensor to the installer side of M2 terminals 4 and 5 (Fig. 8). 4. Refit the boiler terminal block cover, hinge back the control box and replace the boiler case. Fig. 8 8.0 Setting the parameters for the /P R /R + + EcoBlue With the fitted, the boiler central heating flow temperature is adjusted automatically to accommodate the change in heat required to optimise the efficient performance of the boiler whilst maintaining a comfortable room temperature. The central heating buttons on the boiler adjust a simulated room temperature used for this optimisation. Fig. 9 This functionality requires the setting of three parameters on the boiler, to suit the heating system and the optimisation can be adjusted by the user with the central heating control buttons on the boiler control panel. The parameters which must be set are: P03 2 1.75 1.5 2.25 2.5 2.75 3 3.5 4 Boiler Flow Temperature C 100 90 80 P06 = Minimum CH Flow temperature. This should be set to the lowest temperature at which the heat emitters are effective. P07 = Maximum CH Flow temperature. This should be set to the highest flow temperature which can be permitted in the CH circuit. 1.25 1 0.75 0.5 0.25 70 60 50 40 30 P03 = Heating curve (Fig.10). This should be calculated using the following formula: where: P03 = P07 - T room T room - T outmin Fig. 10 C -30-25 - -15-10 5 0 15 10 15 Outdoor Temperature T room = The normal room thermostat setting used by the customer (if this is in doubt or unknown use C), and the temperature to be set on the boiler. T outmin = The minimum expected outdoor temperature, as used for sizing the heating system (recommended value 5 C) TE: parameter P03 can be set to a value in the range 0-4 in increments of 0.02. 7213361-1 (05/14) EcoBlue Accessories 5

Radiator Example P07 - T room 80 - P03 = = = 2.4 T room - T outmin - (-5) Boiler flow temperature ( C) 90 80 70 60 50 40 30 10 0 Fig. 11 T room 15 25-25 - -15-10 -5 0 5 10 15 25 30 Outside Temperature ( C) 35 P07 = 80 C P06 = 50 C 8.0 Setting the parameters for the Figs. 11 through to 13 show three worked examples for different types of heating system. These can be used as a basis for correct system configuration. Example Parameter Recommendations: Radiator systems (Fig 11): P03 = 2.4 P06 = 50 C P07 = 80 C Low Temperature Radiator systems (Fig 12): P03 = 1.4 P06 = 35 C P07 = 55 C Underfloor systems (Fig 13): P03 = 1 P06 = 30 C P07 = 45 C Low Temperature Example Boiler flow temperature ( C) Boiler flow temperature ( C) 90 80 70 60 T room 25 15 50 40 30 10 0-25 - -15-10 -5 0 5 10 15 25 30 Outside Temperature ( C) Fig. 12 P03 = Underfloor Example P07 - T room 55 - = = 1.4 T room - T outmin - (-5) 90 80 70 60 50 T room 25 15 40 30 10 0-25 - -15-10 -5 0 5 10 15 25 30 Outside Temperature ( C) Fig. 13 P03 = P07 - T room 45 - = = 1 T room - T outmin - (-5) 35 P07 = 55 C P06 = 35 C 35 P07 = 45 C P06 = 30 C IMPORTANT: Do not change any other parameters other than those described in these instructions otherwise the warranty of this kit and the boiler could be invalidated. The parameters are set as follows (See Fig. 9): 1. Ensure that there is power to the boiler. 2. Press and hold and until P02 is displayed on screen. 3. Press and hold until On is displayed. 4. Press or to scroll until the required parameter is displayed. 5. Press to edit the program. Press or to change the setting to the desired value. Press to confirm selection. 6. Repeat steps 4 and 5 as required for each parameter. 7. When parameter changes are complete press to return to the normal operating screen. 9.0 Operating instructions with 1. While there is no DHW demand the boiler flow temperature is limited acording to the heating curve setting 2. If the or are pressed while CH is enabled, the display shows a simulated room temperature set point. Ensure that this set point is the same as the room thermostat to ensure optimal outdoor weather temperature compensation operation. The user can adjust this temperature should the optimisation not suit their requirements. 3. While DHW is enabled, if the or buttons are pressed, the display will show the DHW temperature set point. For system boilers ensure that this value is set to at least the same temperature as that set at the DHW cylinder thermostat. This will ensure the desired DHW temperature is achieved. IMPORTANT: Installer should explain to the user how to alter the heating curve using the room temperature set point. 6 EcoBlue Accessories 7213361-1 (05/14)

10.0 Fault Finding TE: The following information is provided for guidance of the Installer, Service Engineer or other competent person. If the control PCB has been replaced check that the EcoBlue Outdoor Sensor Kit has been installed and configured according to these instructions. No or poor DHW performance Ensure DHW mode is enabled on the boiler (tap symbol displayed) Ensure there is a DHW demand Is the DHW tap symbol flashing on the boiler display? Check the temperature settings on the boiler and cylinder thermostat setting if applicable (system boiler) (Refer to section 9) Combi boiler - refer to boiler instruction manual for further fault finding instructions System boiler - Check wiring of relay box is correctly installed as detailed in these instructions (Refer to section 6). Check S-plan wiring and function of cylinder thermostat/zone valve With a DHW demand, is there a 230V supply to terminals 1 & 2 of the relay box? Relay fault, replace relay box With a DHW demand, is there 0V between terminals 5 & 6 of the relay box? Check continuity of wiring between relay box and boiler terminal block M2 connections 9 & 10, and replace if necessary. Check also the wiring harness within the boiler between terminal block M2 connections 9 & 10 and the PCB connection. (See boiler instructions for further detail). 7213361-1 (05/14) EcoBlue Accessories 7

10.0 Fault Finding No or poor CH performance or error code displayed Error 10 displayed Check outside sensor wiring for damage or short circuit. Otherwise replace Outdoor Sensor. If any other error code is displayed refer to appliance manuals for further details then continue with CH fault finding. Review section 9: Has the CH set point been adjusted? Set the CH set point according to section 9 Review Section 8: Setting the parameters for the. Has a sufficient heating curve value been set? Adjust heating curve value to a sufficient value according to section 8. Check all system wiring and components. Check appliance manuals for further detail. All descriptions and illustrations provided in this leaflet have been carefully prepared but we reserve the right to make changes and improvements in our products which may affect the accuracy of the information contained in this leaflet. All goods are sold subject to our standard Conditions of Sale which are available on request. BAXI A Trading Division of Baxi Heating UK Ltd (3879156) Brooks House, Coventry Road, Warwick. CV34 4LL Website www.baxi.co.uk e&oe 7213361-1 (05/14)