- Application A Boiler Control 262 & One Stage Setpoint Control 150. Mechanical Remote Display Module (D1) 040 MODE 1

Similar documents
- Application Boiler Control 260

- Data Brochure Addendum

- Data Brochure Addendum

- Essay Control Functions and Benefits

- Data Brochure Universal Reset Module 423

- Data Brochure Universal Reset Module 422

- Data Brochure D 260. Boiler Control /09

Boiler Demand Mix 1 Demand Mix 2 Demand DHW Demand Setpoint Demand

The Universal Reset Control 363 is a microprocessor based control designed to maximize the comfort and efficiency provided by a hydronic

- Data Brochure Boiler Control 274

U538 12/11. Zoning. Replaces: 08/10. tekmarnet 4 Thermostat 538. User Manual. 1 of U /11

Better Design, Better Control, Better Systems.

- Data Brochure Boiler Control 264

552_U 09/14. tekmarnet Thermostat 552 Zoning Replaces: 08/11. User Manual. 1 of 12. A Watts Water Technologies Company _U - 09/14

MODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL

- Data Brochure Boiler Control 268

- Data Brochure Mixing Control 360

Installation & Operation Manual

- Data Brochure Boiler Control 264e

WWSD. Power. DHW Demand. Maximum. Supply. Minimum Boiler DHW. Zone 1 / Cooling. Pump / Vlv. System Pump. UnOccupied. of full output NRTL/C LR 58223

DHW / Setpoint Demand WWSD Modulation Boiler Output (x10,000 BTU/hr) External Input Signal Offset / Priority Override

MODEL EM-10 ELECTRIC BOILER CONTROL OPERATION AND INSTRUCTION MANUAL

- Data Brochure Universal Reset Control 364

- Data Brochure Mixing Control 361

- Data Brochure Steam Control 279

Hydronic & HVAC Control Systems

- User Brochure tekmarnet 4 Setpoint Control 161

- Data Brochure D 261. Boiler Control 261

- Data Brochure Mixing Reset Module 421

Control Panel Checklist

SC-3 Controller INSTALLATION AND OPERATING INSTRUCTIONS FOR GAS-FIRED, OIL FIRED AND DUAL FUEL HOT WATER HEATING PLANTS. SC-3 Applications CONTENTS

Zoning Solutions. Thermostats & Wiring Centers Designed to Maximize Indoor Comfort. A Watts Water Technologies Company

Installation & Operation Manual

Installation & Operation Manual

Radiant Mixing Block

Heatronic 4000 IO Heatronic /04 en-us. Features. 4 boiler control, DHW, BACnet and Modbus. Installation/Operating instructions (IO)

c0094 form 2. Project Identification Year: 2001 Project nº: 910

B-40/B-41 Modulating Temperature Controller

- Data Brochure. This brochure is for Thermostats 510 and 511 (with sensor). The section on the 079 slab sensor installation is for the 511 only!

- Data Brochure Mixing Control 360e

Instruction Sheet. Press & Hold: Item, to view settings, to test. 24 V ±10% 50/60 Hz 3 VA 120 V (ac) 5 A 1/6 hp pilot 240 VA 20 to 260 V (ac) 2 VA

prestige Control Application Supplement - TriMax

prestige Control Application Supplement - ACVMax

Installation & Operation Manual

Installation & Operation Manual

Control Application. Supplement - ACVMax

Installation & Operation Manual

Installation & Operation Manual

Heat Transfer Products, Inc. 120 Braley Road East Freetown, MA The first totally integrated multiple boiler management control.

- Brochure D 542. Introduction. Features. tekmarnet 4 Thermostat /05. 5 Data Brochure Control settings wiring instructions

- Data Brochure tekmarnet 4 Thermostat 542e

Dual Mixing Application

4 Wiring Brochure Wiring and

prestige Control Application Supplement - TriMax

HPS Controls Ltd. Series 600 LFI / CFI Series 700 HFS Zone Control Stations. Heating and Radiant Floor Zone Control Stations

SC-9 Controller INSTALLATION AND OPERATING INSTRUCTIONS. SC-9 Applications CONTENTS

- Installation & Operation Manual Boiler Control 256

Bosch. Gas Condensing Boiler. Applications Manual. 100, 151 Combi Boiler 57, 100, 131, 151 Heating Boiler

Daikin Altherma/Viessmann Integration Notes (used with schematics M1 thru M5)

Instruction Sheet. Variable Speed - Solar (00-VT) 00 and Load Match Cartridge Circulators

WIRING GUIDE. Form rev.1. Certified to CSA C22-2 No.24 Conforms to UL Standard 873

Installation & Operation Manual

Outdoor Reset IQ Option Card, p/n

- User Brochure Programmable Thermostat 510

Application Guide. Vitodens 100-W B1HA/B1KA Residential Boiler

HPS Controls Ltd. Series 600 LFI / CFI Series 700 HFS Zone Control Stations. Heating and Radiant Floor Zone Control Stations

AQ475A Aquatrol Outdoor Temperature Compensator for Boilers

prestige Control Application Supplement - Type 5 MCBA WARNING

Hydronic Mechanical Panels

BHSAPPMAN 08/00 USA. Applications Manual. Ecomatic / Logamatic Controls. Save These Instructions!

hydronics WHAT S WRONG WITH THIS SCHEMATIC?

heat interface units A BOILER WITHOUT A FLAME

Outdoor Reset IQ Option Card, p/n

A. Base Bid: 1. Heating Contractor provide: a. Control sequences for HVAC systems, subsystems, and equipment.

Product Instructions. Hydronic Mixing Block Version Wiring Terminal Block Pressure/Temperature Sensor Delivery Fitting (3) Display Screen

Installation & Operation Manual

Multi Boiler Guide. Kit #

Commercial Noritz Water Heater Multi-System Application Sheet

Installation & Operation Manual

Outdoor Reset Control Theory FULL versus PARTIAL reset

Service Manual Models:

Applications and Piping Strategies for Condensing Boilers - Introduction

Verasys System Operation Overview Technical Bulletin

Solar Thermal Planning Worksheet Date: / /

Service Manual Models: Series 100 & 101

prestige Control Application Supplement - Type 5 MCBA WARNING

HEAT TROL ELITE SERIES HWE-Single Stage, HWE-MOV, HWE-Mulit Stage Hot Water Reset Control for Light Commercial and Residential Applications Provides q

SUPPLY TO CENTRAL HEATING SYSTEM SUPPLY TO DHW TANK RETURN FROM CENTRAL HEATING SYSTEM RETURN FROM DHW TANK

prestige Control Application Supplement WARNING

Instruction Sheet. Variable Speed - Outdoor Reset (00-VR) 00 Cartridge Circulator

HPS Controls Ltd. Series 100 LTV / CTV Zone Control Stations. Heating and Radiant Floor Zone Control Stations. Installation Instructions

Variable Speed Outdoor Reset 00 Circulator (00-VR)

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND

RVL471. Heating controller. G2524en. Installation Instructions. 1 Installation. 2 Commissioning

G a

IBC Technologies Venables Street, Vancouver, BC, V5L 2G8 - Ph Fax E -

- Data Brochure Snow Detector & Melting Control 667

Service Manual Models:

Circulators high efficiency ECM Circulators

HWE-SS DIGI-El i t e Hydronic Single-Stage Boiler Control

Transcription:

- Application Boiler Control & One Stage Setpoint Control 150 A -1 07/99 echanical Remote Display odule () 040 Outdoor Sensor () 070 150 ODE 1 Class II Transformer 120 V (ac) 24 V (ac) R1 A2 Z1 Z2 Z3 T1 T2 T3 Z7 P4 S4 Heat Exchanger P3 DHW Tank S3 Low / High Fire Boiler Z3 Z3 Z3A 1 B1 Electrical = Pool or Spa High Limit Aquastat A2 = DHW High Limit Aquastat = Remote Display odule 040 (optional) = Boiler Pump = DHW Pump P3 = Pool or Spa Pump P4 = Pool or Spa Recirc. Pump R1 = Relay 003 = Boiler sensor 071 = Outdoor sensor 070 S3 = DHW Sensor 071 S4 = Pool or Spa Sensor 071 T1,.., T3 = Thermostats U1 = tekmar Timer 031 (optional) Z1,.., Z3 = Zone Valve otor End Switches 10A 10A 10A 10A Do not apply power 1 2 3 4 5 6 7 8 9 10 11 1213 14 Boiler ComDHWSetp Demand DemDemDem Power N L Boil DHW Pmp/Vlv 1 Stage Stage 1 2 2 Boiler Low Boiler High 15 16 17 18 19 20 21 22 tn1 / Com 10K UnO Com DHWBoil Out tn2 Sw U1 S3 PW 8A 1 2 3 4 5 6 7 On Power Off C- R+ Com N/O 8A 150 No Power N/C Sensor S4 120 V (ac) L N Class II Transformer 24 V (ac) C T1 T2 T3 R Z1 Z2 Z3 A2 P3 3 4 5 6 R1 2 1 8 7 Note: This is only a concept drawing. The designer must determine whether this application will work in his system and must ensure compliance with code requirements. Necessary auxiliary equipment, isolation relays (for loads greater than the specified tekmar internal relay ratings), and other safety and limit devices must be added. 1 of 8 Copyright 1999 A -07/99

System Operation A -1 07/99 The Boiler Control provides partial or full outdoor reset to three (or more) boiler zones. The Setpoint Control 150 controls the temperature of the pool or spa. The boiler is operated at the temperature required in order to satisfy the loads. The also controls the supply of heat to an indirect Domestic Hot Water (DHW) tank. An optional Remote Display odule (RD) provides remote adjustment and monitoring of the control. Heat Source Details The heat source can be either a high mass or low mass non-condensing boiler or low temperature boiler. If using a low temperature boiler, refer to sections C3 and of the Data Brochure for additional information. Piping Details Thermostat controlled zone valves are piped into the boiler loop. The boiler pump () provides circulation through these zones when heat is required. The pool or spa heat exchanger is piped into the boiler loop and the temperature is controlled through a pump (P3). Heat is supplied to the DHW tank through a DHW pump (). DHW Demand When the DHW sensor (S3) calls for heat, the turns on the DHW pump () and raises the boiler water temperature to at least the DHW TANK setting plus 40 F (22 C). The control maintains the DHW tank temperature at the DHW TANK setting. The control can provide DHW priority (refer to sections C2 and C3 of the Data Brochure) by turning off the boiler pump (). Once the DHW demand is removed, the performs a DHW Post Purge and possibly a ixing Purge. Setpoint Demand The Setpoint Control 150 cycles relay R1 in order to control the heat exchanger pump (P3) and maintain the pool or spa temperature. When the 150 requires heat, it provides a Setpoint Demand to the through relay R1. The increases the boiler temperature to at least the SETPOINT setting. The control can provide Setpoint priority (refer to sections C3 and of the Data Brochure) by turning off the boiler pump (). Boiler Demand When heat is required in the boiler zones, the zone valve end switches send a Boiler Demand to the. The turns on the boiler pump (). The boiler supply water temperature is based on the Reset Ratio or Characterized Heating Curve settings. The boiler is staged to satisfy the required boiler supply water temperature. Whenever the boiler is fired, the aims to increase the boiler temperature to at least the Boil IN setting. All control functions and specifications are listed in the Product Catalog I 000 and the Data Brochure D. Required aterial and Essential Control Settings Required tekmar Products Boiler Control One Stage Setpoint Control 150 Universal Sensor 071 1 x tekmar DPDT Relay 003 Optional tekmar Products Remote Display odule (RD) 040 Timer 031 Essential Application Control Settings (Adjust enu) Item Field Setting ODE 1 STAGE 1 AUTO STAGE 2 AUTO DHW SENS DHW ROTATE OFF Note For all other settings, refer to the Data Brochure D and D 150. Control Systems tekmar Control Systems Ltd., Canada tekmar Control Systems, Inc., U.S.A. Head Office: 4611-23rd Street Vernon, B.C. Canada V1T 4K7 Tel. (250) 545-7749 Fax. (250) 545-0650 Web Site: www.tekmarcontrols.com Product design, software and literature are Copyright 1999 by: tekmar Control Systems Ltd. and tekmar Control Systems, Inc. 2 of 8 All specifications are subject to change without notice. Printed in Canada. A -1 07/99.

Boiler Control - Application A -2 07/99 echanical Remote Display odule () 040 Outdoor Sensor () 070 ODE 1 120 V (ac) T T T P V1 Z1A Z1A B3 B3A Electrical = Remote Display odule 040 (optional) = Boiler Pump = Boiler Sensor 071 = Outdoor Sensor 070 T = Thermostatic Radiator Valve U1 = tekmar Timer 031 (optional) V1 = Balancing valve, globe valve, or pressure differential valve 10A 10A 10A 10A Do not apply power 1 2 3 4 5 6 7 8 9 10 11 1213 14 Boiler ComDHWSetp Demand DemDemDem Power N L Boil DHW Stage Stage Pmp/Vlv 1 1 2 2 15 16 17 18 19 20 21 22 tn1 / Com 10K UnO Com DHWBoil Out tn2 Sw Boiler #1 U1 Boiler #2 120 V (ac) L N Note: This is only a concept drawing. The designer must determine whether this application will work in his system and must ensure compliance with code requirements. Necessary auxiliary equipment, isolation relays (for loads greater than the specified tekmar internal relay ratings), and other safety and limit devices must be added. 3 of 8 Copyright 1999 A -07/99

System Operation A -2 07/99 The Boiler Control provides partial or full outdoor reset to three (or more) thermostatic radiator valve zones. Constant circulation to the zones is provided by the boiler pump (). The boilers are staged as required to provide the supply water temperature that satisfies the loads. An optional Remote Display odule (RD) provides remote adjustment and monitoring of the control. Heat Source Details The heat source can be either high mass or low mass non-condensing or low temperature boilers. Piping Details Thermostatic radiator valve (TRV) zones are piped into the boiler loop. A pressure differential valve (V1) provides a bypass for the boiler pump () in the event that most of the TRV s are closed. The boilers are piped using parallel primary / secondary in order to provide equal and isolated flow through each boiler. Boiler Demand When the outdoor air temperature is below the Warm Weather Shut Down (WWSD) setting, the turns on the boiler pump (). The boiler supply water temperature is based on the Reset Ratio or Characterized Heating Curve settings. The boilers are staged to satisfy the required boiler supply water temperature. Whenever the boilers are fired, the aims to increase the boiler supply water temperature to at least the Boil IN setting. All control functions and specifications are listed in the Product Catalog I 000 and the Data Brochure D. Required aterial and Essential Control Settings Required tekmar Products Boiler Control Optional tekmar Products Remote Display odule (RD) 040 Timer 031 Essential Application Control Settings (Adjust enu) Item Field Setting ODE 1 STAGE 1 AUTO STAGE 2 AUTO Note For all other settings, refer to the Data Brochure D. Control Systems tekmar Control Systems Ltd., Canada tekmar Control Systems, Inc., U.S.A. Head Office: 4611-23rd Street Vernon, B.C. Canada V1T 4K7 Tel. (250) 545-7749 Fax. (250) 545-0650 Web Site: www.tekmarcontrols.com Product design, software and literature are Copyright 1999 by: tekmar Control Systems Ltd. and tekmar Control Systems, Inc. 4 of 8 All specifications are subject to change without notice. Printed in Canada. A -2 07/99.

Boiler Control - Application A -3 07/99 echanical Class II Transformer Remote Display odule () 040 Outdoor Sensor () 070 ODE 1 120 V (ac) 24 V (ac) S3 Z1 Z2 Z3 R1 T1 R2 T2 R3 T3 B4 Z5A Z5A Z5B D9 Electrical = DHW High Limit Aquastat = Remote Display odule 040 (optional) = Boiler Pump = DHW Pump R1,.., R3 = Relay 003 = Boiler Sensor 071 = Oudoor Sensor 070 S3 = DHW Sensor 071 T1,.., T3 = Thermostats U1 = tekmar Timer 031 (optional) Z1,.., Z3 = Zone Pumps 120 V ac Class II Transformer C 24 V ac L N R T1 T2 T3 7 8 6 5 R1 1 4 3 2 7 8 1 2 7 8 1 2 6 5 4 3 6 5 4 3 R2 R3 Z1 Z2 Z3 10A 10A 10A 10A Do not apply power 1 2 3 4 5 6 7 8 9 10 11 1213 14 Boiler ComDHWSetp Demand DemDemDem Power N L Boil DHW Stage Stage Pmp/Vlv 1 1 2 2 Boiler #1 Boiler #2 15 16 17 18 19 20 21 22 tn1 / Com 10K UnO Com DHWBoil Out tn2 Sw U1 S3 Note: This is only a concept drawing. The designer must determine whether this application will work in his system and must ensure compliance with code requirements. Necessary auxiliary equipment, isolation relays (for loads greater than the specified tekmar internal relay ratings), and other safety and limit devices must be added. 5 of 8 Copyright 1999 A -07/99

System Operation A -3 07/99 The Boiler Control provides partial outdoor reset to three (or more) boiler zones. The also controls the supply of heat to an indirect Domestic Hot Water (DHW) tank. The boilers are staged as required to provide the supply water temperature that satisfies the loads. An optional Remote Display odule (RD) provides remote adjustment and monitoring of the control. Heat Source Details The heat source can be either high mass or low mass non-condensing boilers. Piping Details Thermostat controlled zone pumps are piped off the boiler loop as a secondary loop. Heat is supplied to the DHW tank through a DHW pump (). The boilers are piped in reverse return in order to ensure equal flow through both boilers. The boiler pump () provides flow through the boilers and ensures flow past the DHW tank take-off and the zone pump take-off. DHW Demand When the DHW sensor (S3) calls for heat, the turns on the DHW pump () and the boiler pump () and raises the boiler water temperature to at least the DHW TANK setting plus 40 F (22 F). The control maintains the DHW tank at the DHW TANK setting. Once the DHW demand is removed, the performs a DHW Post Purge and possibly a ixing Purge. Boiler Demand When heat is required in the heating zones, the zone pump relays send a Boiler Demand to the. The turns on the boiler pump (). The boiler supply water temperature is based on the Reset Ratio or Characterized Heating Curve settings. The boilers are staged to satisfy the required boiler supply water temperature. Whenever the boilers are fired, the aims to increase the boiler supply water temperature to at least the Boil IN setting. All control functions and specifications are listed in the Product Catalog I 000 and the Data Brochure D. Required aterial and Essential Control Settings Required tekmar Products Boiler Control 3 x tekmar DPDT Relay 003 Optional tekmar Products Remote Display odule (RD) 040 Timer 031 Essential Application Control Settings (Adjust enu) Item Field Setting ODE 1 STAGE 1 AUTO STAGE 2 AUTO DHW THRU VALV DHW SENS DHW Note For all other settings, refer to the Data Brochure D. Control Systems tekmar Control Systems Ltd., Canada tekmar Control Systems, Inc., U.S.A. Head Office: 4611-23rd Street Vernon, B.C. Canada V1T 4K7 Tel. (250) 545-7749 Fax. (250) 545-0650 Web Site: www.tekmarcontrols.com Product design, software and literature are Copyright 1999 by: tekmar Control Systems Ltd. and tekmar Control Systems, Inc. 6 of 8 All specifications are subject to change without notice. Printed in Canada. A -3 07/99.

Boiler Control - Application A -4 07/99 echanical Remote Display odule () 040 ODE 2 Alarm 120 V (ac) 3 D6 B4 Electrical = DHW High Limit Aquastat (optional) = Remote Display odule 040 (optional) = Boiler Pump = DHW Recirc. Pump = Boiler Sensor 071 = DHW Sensor 071 U1 = tekmar Timer 031 (optional) 10A 10A 10A 10A Do not apply power 1 2 3 4 5 6 7 8 9 10 11 1213 14 Boiler ComDHWSetp Demand DemDemDem Power N L Boil DHW Stage Stage Pmp/Vlv 1 1 2 2 15 16 17 18 19 20 21 22 tn1 / Com 10K UnO Com DHWBoil Out tn2 Sw Boiler #1 U1 Alarm Boiler #2 N/O N/C 120 V (ac) L N Note: This is only a concept drawing. The designer must determine whether this application will work in his system and must ensure compliance with code requirements. Necessary auxiliary equipment, isolation relays (for loads greater than the specified tekmar internal relay ratings), and other safety and limit devices must be added. 7 of 8 Copyright 1999 A -07/99

System Operation A -4 07/99 The Boiler Control provides control of two boilers for a dedicated Domestic Hot Water (DHW) storage system. An optional Remote Display odule (RD) provides remote adjustment and monitoring of the control. Heat Source Details The heat source can be high mass or low mass non-condensing or low temperature boilers or any boilers designed for this type of application. Piping Details The boilers are piped in reverse return providing equal flow through each boiler. The DHW recirculation loop pump () provides constant hot water flow past the fixtures. DHW Demand When the DHW sensor () calls for heat, the turns on the boiler pump () and raises the boiler water temperature to at least the DHW TANK setting plus 40 F (22 C). The control maintains the DHW tank temperature at the DHW TANK setting. The RD is capable of sounding an alarm if the DHW tank overheats. When the DHW high limit aquastat () is triggered, the receives an external DHW Demand. When the receives the demand, a DHW Error (DHW ERR) is registered and the alarm contact of the RD is closed. To clear this error, refer to the Data Brochure D. Recirculation The recirculation pump () operates continuously when the control is in the Occupied mode. The recirculation pump () is turned off when the control is in the UnOccupied mode. All control functions and specifications are listed in the Product Catalog I 000 and the Data Brochure D. Required aterial and Essential Control Settings Required tekmar Products Boiler Control Optional tekmar Products Remote Display odule (RD) 040 Timer 031 Essential Application Control Settings (Adjust enu) Item Field Setting ODE 2 STAGE 1 AUTO STAGE 2 AUTO DHW SENS DHW Note For all other settings, refer to the Data Brochure D. Control Systems tekmar Control Systems Ltd., Canada tekmar Control Systems, Inc., U.S.A. Head Office: 4611-23rd Street Vernon, B.C. Canada V1T 4K7 Tel. (250) 545-7749 Fax. (250) 545-0650 Web Site: www.tekmarcontrols.com Product design, software and literature are Copyright 1999 by: tekmar Control Systems Ltd. and tekmar Control Systems, Inc. 8 of 8 All specifications are subject to change without notice. Printed in Canada. A -4 07/99.