COURSE 474 CONTINUOUS EMISSION MONITORING Extended Agenda

Similar documents
SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

Emissioni convogliate in atmosfera: Sistemi di monitoraggio in continuo delle emissioni SME

International comparison of validation methods for dust concentration measurement

4500MkIII COMPLIANCE OPACITY AND DUST MONITORING QAL 1 PS-1 ASTM D6216 PROCEDURE 3 PS-11 QUALITY CUSTOMER SOLUTIONS

Laser Diagnostics and Optical Measurement Techniques

Boiler MACT Deadline Is Here, Are You In Compliance? Sponsored by

This SOP and the B.C. Field Sampling Manual are available at: www2.gov.bc.ca.

Compact Sensor Heads for In-situ and Non-Contact Standoff Gas Sensing using TDLAS in Harsh Environments

CURRENT EQUIPMENT UPDATES AND CHANGES

THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11

Complete Gas Analysis

Title: Standard Operating Procedure for Measurement of Total Hydrocarbon Using a Flame Ionization Detection

Boiler MACT Webinar Q/A

Propagation loss in optical fibers (01/29/2016)

An FT-NIR Primer. NR800-A-006

continuous emissions monitoring Combustion & Environmental Monitoring

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

PRODUCT CONFORMITY CERTIFICATE

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Chemistry Instrumental Analysis Lecture 4. Chem 4631

Laser Safety. This Laser Safety Program applies to the acquisition, use, transfer, and disposal of all Class 3B and 4 lasers at UNC Asheville.

National Atomic Energy Commission ( NATEC ) Radiation Exposure and Laboratories General Directorate

CEMTEK KVB-ENERTEC 2018 NetDAHS EDGE SEMINAR & TRAINING Hilton Hotel, Costa Mesa, CA *Preliminary Agenda - Agenda subject to change* Monday, 9/10/18

MultiGAS Monitoring System Hot/Wet IR Analyzer Technology. Clean Air Systems

ISO INTERNATIONAL STANDARD. Coating powders Part 13: Particle size analysis by laser diffraction

ice 3000 Series Atomic Absorption Spectrometers Flame and furnace AAS analysis for routine laboratories

ice 3000 Series Atomic Absorption Spectrometers Flame and furnace analysis for routine laboratories

The Emergence of Triboelectric Technology

Cone Calorimeter. (ISO 5660 ASTM E 1354) The most comprehensive bench scale fire test THE BENCHMARK IN FIRE TESTING

Many different instruments Many different operating principles including: May sample many different gases & vapour From relatively simple to complex

Mercury Vapor Monitor VM-3000

Leak Detection and Repair METHOD 21 AND OPTICAL GAS IMAGING

EMS510 PS-1 COMPLIANT OPACITY/DUST MONITOR

New European Cable Testing and Classification

Thank You for Attending Today s Webinar:

CEM Istanbul - Turkey. True trace emission monitoring system

Laser Analyzers for NH3 Safety Monitoring and Leak Detection

INSTRUMENTATION FOR MARINE BLACK CARBON MEASUREMENTS

Fundamentals is subdivided into Sources of Radiation, Biological Effects, Mathematics, Chemistry, Physics, and Units and Terminology.

NO NO 2 NO x SO 2 CO CO 2 O 2

Software Failure Mode and Effects Analysis of Concept Phase for Radiation Monitoring System Digital Replacement

RLDS - Remote LEAK DETECTION SYSTEM

Real-time Monitoring Technology for Preservation Environment of Archives

INTERNATIONAL STANDARD

APPROVED by U.S. EPA As a Class III Equivalent Method Designation for the measurement of PM 2.5

VM-3000 Mercury Vapor Monitor

Certificate: _01 / 29 April 2014

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

New Features TDLS 200. The Process TDLS Solution. Tunable Diode Laser Spectroscopy (TDLS) Analyzer.

A Cost Effective Multi-Spectral Scanner for Natural Gas Detection

SPECTRAL INSTRUMENTATION

99 Washington Street Melrose, MA Phone Toll Free Visit us at

UltraCEM-P Indoor Continuous Emissions Monitoring System. Clean Air Systems

VM-3000 Mercury Vapor Monitor

EAGLE 2X: C155KIT EAGLE 3X: C157KIT

Automatic Isokinetic Sampler ST5

Chapter 1. Introduction

North Dakota State University Laser Safety

state of the art methane leak detection CHARM and GasCam 2011 October 13 th Dr. Axel Scherello

mach 5 100kHz Digital Joulemeter: M5-SJ, M5-IJ and M5-PJ Joulemeter Probes

Instrumental technique (MCP detectors) - Kamalesh ( )

Laser Particle Size Analyzer

Paul Kotrappa, Ph.D. and Carolyn Allen. Rad Elec Inc., 5714-C Industry Lane, Frederick, MD USA

Safe Operation Manual. Honeywell IQ Force Gas Detector

Product data sheet Palas Fidas 200 S

Omnisens DITEST TM FIBER OPTIC DISTRIBUTED TEMPERATURE & STRAIN SENSING TECHNIQUE

Optical methods for monitoring gas turbine emissions

CERTIFICATE of Product Conformity (QAL1 )

IMPROVE Aerosol Monitoring Network

PRODUCT CONFORMITY CERTIFICATE

Distributed Temperature Sensing

Emission Monitoring System

UltraCEM All Weather Continuous Emissions Monitoring System. Clean Air Systems

SafEye OPEN-PATH GAS DETECTION SYSTEM XENON 700. We INVENTED it... We PERFECTED it! Patent No. US 5,281,816; US 6,061,141; EP

THE NEXT GENERATION IN VISIBILITY SENSORS OUTPERFORM BOTH TRADITIONAL TRANSMISSOMETERS AND FORWARD SCATTER SENSORS

metro B6012 VIBRATIONS SIMPLIFIED... Product brochure Easiest portable vibration analyzer and balancer TECHNOLOGIES PVT. LTD.

高等食品分析 (Advanced Food Analysis) II. INSTRUMENTS FOR OPTICAL SPECTROSCOPY *Instruments for optical spectroscopy: Optical spectroscopic methods are

Communications. Sensing. Instrumentation. Delivering tomorrow s optical and photonic solutions today. BREAKTHROUGH PHOTONIC PRODUCTS

Advances in Leak Detection in the Manufacturing Process

Compression of Fins pipe and simple Heat pipe Using CFD

Meets all design requirements of U.S.EPA. Double pass optical system for accuracy and sensitivity. Modulated light beam to eliminate interference

Important Safety Notice

PSA Series. Particle Size Analyzer

Date: Wednesday, January 31, 2018 Time: 8:30 am 5:00 pm Location: Moscone West (Room 2018, Level 2)

Rutgers Environmental Health and Safety (REHS)

HUMIDITY MEASUREMENT BENEFITS IN POWER PLANT APPLICATIONS. Jeff Bossong, H 2 O

Specifications Wavelength Range: 190 nm to 800 nm continuous

Milano, 25 novembre 2015

Smoke Detector Testing

The New DUSTTRAK II and DRX Aerosol Monitors

Atomic Absorption Spectrophotometer AAS 2320D EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES

CERTIFICATE. on Product Conformity (QAL 1) Number of Certificate: _02

3.4 Humidity. Types of instruments

AAnalyst 700 Atomic Absorption Spectrometer

Infrared Carbon Dioxide Sensor Module CM1106SL

MSA s Guide to Selecting the Right Flame Detector for Your Application

Rol van ISSeP als sectoraal operator

CEM Mars 5 Microwave Accelerated Reaction System

Transcription:

COURSE 474 CONTINUOUS EMISSION MONITORING Extended Agenda Day 1 Regulatory Requirements for CEM Systems (Part 60) 1. Intro to Emission Monitoring a. What is measured? b. Measuring techniques c. Manual Methods d. Continuous Methods 2. Clean Air Act of 1970 CEM Requirements 3. Existing source vs New Source CEM Requirements 4. Part 60 New Source Performance Standards a. The Subparts b. Appendix A Manual Methods c. Appendix B - CEM Performance Specifications d. Appendix F CEM QA Regulatory Requirements for CEM Systems (Part 75 and Part 63) 1. Allowances and Trading a. Why Trading? b. The Role of CEMS 2. Acid Rain Program a. Finding your way in Part 75 b. New Concepts in Part 75 c. Net Results for CEMS 3. NOx Budget a. Role of the States 4. CAIR 5. Technical Assistance Tools 6. 40 CFR 63 MACT Rules a. Affected Sources b. Monitoring Requirements 7. Subpart A The General Provisions a. CEM Requirements b. Differences between Part 60 and Part 63 c. Monitoring for Compliance 8. The MATS Rule Subpart UUUUU (Utility MACT) 9. Subpart MACT for Petroleum Refineries Sampling System Options Source Level and Dilution Extractive Systems 1. Source Level Systems a. Cool-dry Extractive systems i. Probe ii. Sample Line iii. Chillers iv. Pumps b. Hot-Wet Systems 2. Dilution Extractive Systems a. In-stack The Kipp Probe b. Out-of Stack systems i. STI Probe ii. M&C Probes iii. T, P, and MW effects on Dilution Systems

Basics for Electro-optical Analyzers 1. Energy and Light 2. Interaction of Light with Molecules a. Infrared b. UV 3. The Beer Lambert Law 4. Building an analyzer Day 2 Extractive System Monitoring Instrumentation 1. Electro-Optical Techniques a. Photometric Methods i. Photometry ii. Gas Filter Correlation iii. Differential Absorption Fourier Transform Infrared Spectroscopy b. Luminescence Methods i. Fluorescence ii. Chemiluminescence 2. Electroanalytical Techniques a. Polarography b. Paramagnetism c. Gas Chromatography 3. Developments in Analyzers In-situ Monitors for Gases 1. Path Monitors a. Optical Depth b. Calibration Issues c. Laser systems for HCl and NH 3 2. Point Monitors a. Calibration Issues b. Systems 3. Advantages and Disadvantages 4. Alternative Quarterly Test Criteria Units of the Standard and Flow Monitoring (CERMS) 1. Units of the Standard a. Concentration Corrections b. Emission Rate Standards c. Thermal d. Mass Rate 2. F-Factors a. Dry F Factor b. Wet F Factor c. Tricks with F Factors 3. Flow Monitoring a. Flow Monitoring Techniques b. Differential Pressure c. Thermal Sensing Systems d. Acoustic Velocimetry e. Time-of-Flight Methods 4. Certifying a Flow Monitor a. Comparison against Method 2 b. K Factors 5. Alternate Reference Methods a. Method 2 F b. Method 2 G c. Method 2 H

Monitoring for Mercury (CMMS) 1. Mercury in Flue Gases a. Cement Plants b. Coal-fired Power Plants 2. Manual Source Testing Methods a. Methods 101 A and 29 b. Ontario Hydro Method c. Method 30A Instrumental Method d. Method 30B Carbon Trap Method 3. CMM Methods a. Conversion to Elemental Mercury b. Speciating vs non-speciating systems c. Cold Vapor Atomic Absorption Spectroscopy d. Vapor Atomic Fluorescence Spectroscopy e. Zeeman Modulated Atomic Absorption Spectroscopy 4. Periodic Sampling Sorbent Tube Sampling Certifying a CEM System 1. CEM Systems Design Requirements 2. CEM System Installation 3. CEM Certification a. 7-day Drift Test b. Response Time Test c. RATA d. Source Testers and ASTM D7036 e. The Test Plan f. Conducting the Test g. Calculations i. Relative Accuracy ii. Bias h. Causes for Failure of the RATA Conducting the RATA Group Problem 1. The Class will be divided into groups of 3 2. Half of the groups are Source Tester Companies/ The other half CEM Owners 3. Each group is given an analyzer 4. Each Source Testing Company will conduct a RATA on the emission source of the CEM Owners who will be operating their CEM system 5. Each group will calculate the relative accuracy (RA) for the test Day 3 Opacity monitoring (COMS) 1. Light Scattering Phenomena a. Rayleigh Scattering b. Mie Scattering c. Geometric Optics 2. Optical Density Calculations a. Pathlength Correction Factor b. Combiner Equation c. Bouger Law Correlations 3. ASTM D6216 Design Specifications a. Manufacturer s Specifications b. The MCOC 4. Opacity Monitor Operational Design a. Single Pass b. Double Pass 5. 40 CFR 60 Appendix B Performance Specification 1

a. Performance Specification b. Certification 6. 40 CFR 60 Appendix F Procedure 3 a. Daily Checks b. Quarterly Audits Audit Filters c. Annual Zero Alignment Monitoring for Particulate Matter 1. Correlation Methods a. PS11 and ISO 10155 b. PM CPMS Definition and Applicability 2. PM Monitoring Techniques a. Beta Radiation Attenuation b. Light Scattering (Forward, Back, and Side) c. Electrodynamic Techniques 3. PM Monitoring in Wet Stacks 4. Bag Leak Detectors and ASTM D7392 5. PM 10/2.5 Manual Methods Data Acquisition Systems and Reporting 1. The Total System a. Controllers b. Role of the Computer c. Networks 2. Functions of the DAS/DAHS 3. Minimum Screen Requirements a. Default Screens b. Alarm Screens c. Data/QC Screens d. Data Base 4. Averaging Requirements a. Block Averages b. Rolling Averages for the Utilities and Refineries 5. Electronic Reporting a. Part 60 b. Part 75 Predictive Emission Monitoring Systems and PS16 1. Reasons for using PEMs a. Rationale as an Alternative to CEMS b. Federal Part 75 Criteria c. State Issues 2. Parameters and Sensors a. O&M Indicators b. Parameter Surrogates 3. Predictive Systems a. Phenomenological Models b. Empirical Models c. Least Squares Methods d. Neural Net Methods 4. 40 CFR 60 Performance Specification16 a. Design Criteria b. Certification c. QA/QC 5. 40CFR60 Performance Specification 17

CEM Quality Assurance Principles and Requirements 1. Quality Assurance Objectives a. Precision b. Accuracy c. The True Value 2. A Total CEM System Quality Assurance Program a. Purchasing a System b. Certifying a System c. Continuing Operation d. The QA Plan e. Writing the Plan f. Implementing the Plan g. The Agency and its responsibilities with respect to the CEM QA Plan h. Approaches to Maintenance i. The CEM Logbook j. Declaring Obsolescence 3. Availability k. Par t 60 Role in Excess Emission Reports l. Part 75 Availability and Missing Data Substitution Performance Audits A Review Session 1. The Daily Calibration Verification a. Criteria and Significance b. Quality Control Charts 2. The Cylinder Gas Audit (CGA)/Linearity Error a. Part 60-40 CFR 60 Appendix F b. Part 75-40 CFR 75 Appendix B 3. The Annual/Semi-annual RATA a. Part 60-40 CFR 60 Appendix F b. Part 75-40 CFR 75 Appendix B 4. The Flow-to-Load Ratio Test 5. The Opacity Monitor Audit 6. Optional Techniques 7. Availability a. Part 60 and Excess Emission Reports b. Part 75 and Missing Data Substitution c. CEM Performance today Systems Audits - Inspecting CEM Systems 1. Types of Systems Audits a. Internal b. External 2. The Audit/Inspection a. Use of Checklists b. Entrance Briefing c. The Site Tour d. Interviews/Discussions e. Records Review f. Exit Briefing 3. The Audit Report