Technical Manual Manual Técnico

Similar documents
TECHNICAL SERVICE MANUAL SCALA - SC

TECHNICAL SERVICE MANUAL

Trouble Shooting Guide PWA, 3-phase (D10571)

Trouble Shooting Guide FAA, 3-phase (D3631)

USER MANUAL WATER DISPENSER WITH ICE MAKER

Trouble Shooting Guide RAA, 1-phase (D3627)

Trouble Shooting Guide PAA, 1-phase (D3731)

Packaged Heat Pumps. Owner s Guide to Operating and Maintaining Your Heat Pump

Fig. 1 - Unit PHD4 and WPH4

Power Pack Service Manual

ICE/BEVERAGE DISPENSER

Owner s Information Manual

Operating Instructions

CH250 AND CH251 CHILLERS

APW PSI PRESSURE WASHER

Automatic Ice Maker. Service Manual VT ICEMAKER 15

TECHICAL SERVICE MANUAL

C C C-600 INSTRUCTION MANUAL ICE CUBES MACHINE. (including: exploded views, part list & diagrams) CUISIMAT

NON-CYCLING REFRIGERATED AIR/GAS DRYERS QPNC 75 to QPNC 250 OPERATOR S MANUAL

Power Pack Service Manual

Installation & Operating Instructions

MODULAR AUTOMATIC GRANULAR ICE FLAKER

INDEX. Granita Machine. Operation a nd Instruction Manual

INSTALLATION MANUAL ICE/BEVERAGE DISPENSER MODEL: ENDURO-200/250

ICED CAPPUCCINO MACHINE Taylor MODEL: 390

INSTALLATION AND USER MANUAL

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table)

CQUBE EVO OPERATION MANUAL EVO_OM_VKI_EN. Part No.: _06

OPERATING & SERVICE PARTS MANUAL HDS-215 COMBINATION SHRINK SYSTEM

SPLIT TYPE. Instruction manual

DOMESTIC ICE MACHINE USER INSTRUCTION MANUAL MODEL TS-061

Undercounter Ice and Water Dispenser with Chewblet Ice Machine 7UC100A, 7UD100A

541D19 SERIES. Technical Manual. A Division of Aquion Partners L.P.

Operator s Manual. IP-100 Immersion Probe Cooler

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

OPERATOR S MANUAL ICE/BEVERAGE DISPENSER. Model: Enduro Valve

- 1 - Updated on 18 March, 2010

SAVE THESE INSTRUCTIONS HOUSEHOLD USE ONLY

50-Pound Portable Ice Maker

Fig. 1 - Unit PGD4, PGS4, WPG4

Pet. Easy Guide. VAX Ltd., Kingswood Road, Hampton Lovett, Droitwich, Worcestershire, WR9 OQH, UK - website:

CHILLER. Model CH3000. Operator s & Installation Manual

USER MANUAL UN-200V / UN-200VH

ICE DISPENSER. D45 and D90 Installation Manual. Release Date: August, 1995 Publication Number: Revision Date: March 27, 2014 Revision: D

Installation Guide BUILT-IN SXS REFRIGERATOR UPSXB2627**

Bliss Box Former Troubleshooting. 6.1 Troubleshooting Chart. Troubleshooting INTRODUCTION SAFETY PROCEDURES

KQ Series. Multistage Booster Pump System. Installation Manual. ISO 9001 Certified KQ200/400 KQ800

POWER PACK SERVICE MANUAL

Technical Data. Name: ERIKA Automat fully automatic machine to divide and to round dough pieces of the same size

AUTOMATIC GRANULAR ICE FLAKER

BL Series INSTRUCTIONS

OPERATING INSTRUCTIONS

Installation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro

Owner s Information Manual

OWNER S MANUAL Dehumidifier GDN50AP-A3EBA1A GDN70AP-A3EBA1B

INSTALLATION, COMMISSIONING AND OPERATING MANUAL

INSTRUCTION AND MAINTENANCE MANUAL DRYERS A5 - A6 - A7 - A7,5 - A8 - A9 - A10

BEFORE USING THE APPLIANCE

INSTRUCTION AND MAINTENANCE MANUAL

AUTOMATIC MODULAR ICE FLAKER

PS-2/ES Automated pack & tag machine with IndES fastening system

INSTRUCTION MANUAL BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

XD-125 OWNER S MANUAL COMMERCIAL DEHUMIDIFIER

SCHWAN INSTALLATION GUIDE

Gas Fire Patio Heater Q9

INSTALLATION INSTRUCTIONS FOR SERIES 9 INTERMITTENT PILOT IGNITION CONTROL

Carmen. Operating Instructions. 1

Operation Manual. Instructions for Installation, Operation & Maintenance. PortaPac 5-, 8 and 10-ton Portable Air Conditioners

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHTS200A EKHTS260A EKHTSP200AA EKHTSP260AA

HT650 TM FAN DRIVE SERVICE INSTRUCTIONS

HX-30/40 and HX-30/40 S Glass and Dishwashers

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

BGH Series Hot Surface Ignition Control

INSTRUCTION AND MAINTENANCE MANUAL DRYERS A 11 - A 12 - A 13 - A 14 (R410A)

HID312, HID525 and HID540 Service Parts

Power Pack Service Manual

USER S MANUAL ATH WH220

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

T-Series Air Conditioner T15 Model

DK-11 Countertop Water System. Owner's Manual

G-7s. Instruction Manual. G-Series Cooler COUNTERTOP COOLER. Part No.11IPA

Installation & Operating Guide

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

T-Series Air Conditioner T53 Model

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

Installation Instructions

PARALLEL RACK SYSTEM INSTALLATION & OPERATIONS MANUAL With Master Rack Compressor Sequencer

PRO 2000i LOW LEVEL DEPOSITOR

Maintenance regulations Service intervals SCA

Operator Manual NA 9328 Prof XL pump

Undercounter Ice and Water Dispenser with Chewblet Ice Machine E7UC100A, E7UD100A

T-Series Air Conditioner T20 Model

Audi-Larm Audible Alarm

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Portable Air-conditioner Use and Care Manual

POWER PACK SERVICE MANUAL

INSTALLATION MANUAL ICE/BEVERAGE DISPENSER MODEL: ENDURO VALVE

TECHNICAL SERVICE GUIDE

Medical Refrigerator

ICE/BEVERAGE DISPENSER MODELS: ENDURO-150 (SIX VALVE) INSTALLATION MANUAL

Transcription:

Technical Manual Manual Técnico

TECHNICAL SERVICE MANUAL SCL - SC MODELS: SCL 400 - SC 400 SCL 600 - SC 600 SCL 1T - SC 1TN SCL 2T - SC 2TN SCL 3T - SC 3TN SCL 5T - SC 5TN SCL 10T - SC 10TN SCL 15T - SC 15TN TABLE OF CONTENTS 1. INTRODUCTION 4 Warnings 4 Overview 5 Wiring Diagram 6 2. SPECIFICATIONS 8 Production Tables 11 3. DELIVERY AND UNPACKING 13 4. INSTALLATION 13 Recommended Placement of Unit 13 Installation Procedure 14 5. OPERATION 14 Preliminary Checks 14 Starting up 14 Stop 15 6. MAINTENANCE AND CLEANING INSTRUCTIONS 15 7. TROUBLESHOOTING 16 3

CAREFULLY READ THE INSTRUCTIONS CONTAINED IN THIS MANUAL SINCE THEY PROVIDE IMPORTANT INFORMATION RELATIVE TO SAFETY DURING INSTALLATION, USE, AND MAINTENANCE. THIS APPLIANCE SHOULD BE INSTALLED BY APPROVED TECHNICAL SERVICE PERSONNEL. INTRODUCTION Thank you for choosing SCL - SC Ice Maker. You have purchased one of the most reliable ice-making products on the market today. Carefully read the instructions contained in this manual since they provide important information relative to safety during installation, use, and maintenance. 1. Warnings This appliance should be installed by approved Technical Service Personnel. This plug should be accessible at all times. To reduce the risk of electrical shock, ALWAYS disconnect the machine BEFORE cleaning or maintaining the equipment. Do not attempt to install, service, or modify this machine. Improper use by other than specially trained technicians is extremely dangerous and may result in a fire or electric shock. This machine should not be placed outdoors or exposed to rain. Connect to drinking water mains. This appliance is not intended for use by young children or infirm persons without supervision. Young children should be supervised to ensure that they do not play with the appliance. IMPORTANT! DO NOT ATTEMPT TO SERVICE THIS MACHINE AS IT IS DANGEROUS AND COULD CAUSE SEVERE DAMAGE TO THE UNIT. SERVICE SHOULD ONLY BE CARRIED OUT BY TRAINED, QUALIFIED PERSONNEL. WE STRONGLY RECOMMEND USING ONLY ORIGINAL REPLACEMENT PARTS AVAILABLE FROM AN AUTHORIZED DISTRIBUTOR. WASTE AND OTHER MATERIAL SHOULD BE DISPOSED OF ACCORDING TO LOCAL REGULATIONS AND PROCEDURES FOR WASTE DISPOSAL. CLEANING AND MAINTENANCE ARE NOT COVERED BY THE WARRANTY. 4

2. Overview Read this service manual carefully before installation, debugging and operation of this ice machine. This Service Manual gives an introduction of operation conditions, performance parameters, installation and debugging and operating procedures of SCL - SC ice machines. The ice machine system is of vertical, internal ice scraping type. The machine is equipped with an electric box with different protections and status lights, namely: (1) Ice level (2) Water pressure (3) Normal operation of reducer s electromotor (it uses a speed driver) (4) Low and high pressure switch (compact models) (5) Water pump on/off (6) Unit on/off In addition, an alert indicator lights up to indicate the cause of stoppage, thus facilitates the trouble shooting and maintenance. 5

3. Wiring Diagram COMPACT SCL - SC 6

COMPACT SCL - SC with V/f driver E N G L IS H

SCL SPLIT - SC SPLIT E N G L IS H

7 SCL SPLIT SC SPLIT with V/f driver

SPECIFICATIONS SCL 400 - SC4 00 / SCL 600 - SC 600 MODEL 400 600 PRODUCTION 0,4T 0,6T REFRIGERANT R449A POWER 1425W 2350W AMBIENT TEMPERATURE WATER TEMPERATURE 25oC 16oC WATER CONSUMPTION 17 L/H 25 L/H WATER INLET DRAIN ELECTRICAL REQUIREMENTS 3/4 GAS 21mm 380/50Hz/3N DIMENSIONS 1090x700x720 1250x750x820 WEIGHT 180 290 DIMENSION OF ICE OUTLET 326mm 8

SCL 1T - SC 1TN / SCL 2T - SC 2TN / SCL 3T - SC 3TN Pipe connection diagram and installation measurement and size of ice outlet of 1-3-ton ice-maker. PIPE CONNECTION PIPE CONNECTION DIMENSIONS OF ICE OUTLE MODEL A B C D E L W H Ø SCL 1T - SC 1TN 150 750 198 490 310 1050 850 870 480 SCL 2T - SC 2TN 150 750 198 490 310 1050 850 1080 480 SCL 3T - SC 3TN 150 750 198 490 310 1050 850 1300 480 9

Pipe connection diagram and installation measurement and size of ice outlet of 5-ton and above ice-maker. PIPE CONNECTION PIPE CONNECTION DIMENSIONS OF ICE OUTLE E N G L I S H MODEL A B C D E F G H I J L M Ø SCL 5T - SC 5TN 1850 1150 1000±1 250 1050±1 50 775 575 1100 950 650 150 900 SCL 10T - SC10TN 1850 1150 1000±1 250 1050±1 50 775 575 1600 1500 650 150 900 SCL 15T - SC 15TN 2510 1800 1230±1 285 1700±1 50 900 900 2200 1950 960 250 1580 SCL 20T - SC 20TN 2510 1800 1230±1 285 1700±1 50 900 900 2400 2250 960 250 1580 SCL 25T - SC 25TN 2510 1800 1230±1 285 1700±1 50 900 900 2600 2450 960 250 1580 SCL 30T - SC 30TN 2835 2135 1514±1 280 2035±1 50 1067.5 1067.5 2700 2550 1150 250 1915 SCL 35T - SC 35TN 2835 2135 1514±1 280 2035±1 50 1067.5 1067.5 3200 3050 1150 250 1915

1. Production Tables SCL 400 - SC 400 Ta/Tw 5 10 15 20 26 32 38 10 460 450 440 410 360 340 300 25 420 410 400 370 330 290 250 30 350 340 330 300 260 200 200 38 320 310 290 260 220 180 150 SCL 600 - SC 600 Ta/Tw 5 10 15 20 26 32 38 10 680 670 640 610 560 550 500 25 640 610 600 580 550 530 510 30 560 540 530 500 480 460 450 38 500 490 480 460 440 430 400 SCL 1T - SC 1TN Ta/Tw 5 10 15 20 26 32 38 10 1200 1100 1050 1000 900 830 750 25 1100 1000 950 900 850 780 690 30 900 950 850 800 680 600 580 38 880 850 780 700 620 580 500 SCL 2T - SC 2TN Ta/Tw 5 10 15 20 26 32 38 10 2350 2300 2100 1900 1800 1700 1500 25 2200 2100 1900 1850 1700 1500 1300 30 1900 1800 1650 1500 1300 1200 1100 38 1700 1650 1600 1400 1250 1000 900 11

SCL 3T - SC 3TN Ta/Tw 5 10 15 20 26 32 38 10 3400 3300 3200 3000 2700 2500 2200 25 3300 3200 3000 2800 2500 2300 2000 30 2900 2700 2500 2300 2000 1800 1700 38 2600 2500 2400 2100 1900 1700 1580 SCL 5T - SC 5TN Ta/Tw 5 10 15 20 26 32 38 10 5600 5500 5200 5000 4600 4200 3800 25 5400 5300 5000 4600 4300 3900 3400 30 4900 4600 4300 3900 3400 3000 2900 38 4400 4300 4000 3600 3200 2900 2500 SCL 10T - SC 10TN Ta/Tw 5 10 15 20 26 32 38 10 11500 11200 10900 10000 9000 8300 7500 25 10900 10700 10000 9200 8500 7800 6900 30 9900 9000 8500 7900 7800 6000 5500 38 8700 8500 8000 7100 6300 5900 5700 12

DELIVERY AND UNPACKING Upon receipt, thoroughly inspect the packing container. If there appears to be damage to the container contact the shipper immediately. Unpack unit in the presence of delivery personnel noting any damage on the waybill. ITV packing bears the Green Point on all models according to the European Directives on management of Packaging and Waste Disposal. Be sure to include model name and serial number on all claims. Serial number is located in the following three places: 1) Packing There is a label stuck onto the cardboard packing bearing this serial number (1). 2) Machine body On the back of the machine (1). 3) Machine body Located at the back of the machine, rating plate. Verify that the installation KIT is inside the bin, and has the following pieces:. 3/4 water hose, two small filters and user manual.. Dischareg hose. (1) WARNING: DO NOT LEAVE PACKING MATERIALS (PLASTIC BAGS, CARDBOARD BOXES, ETC.) WITHIN REACH OF CHILDREN. INSTALLATION 1. Recommended Placement of Unit Sockets and wiring must comply with local standards for electrical appliances and requirements set forth on the rating plate of the machine. Air switch must be installed within an immediate touch and shall be chose in line with the current of various types of machines, and earth wires shall be installed in assigned position on the baseboard or in the electric case according to relevant standards. Continual water supply shall be guaranteed for the machine (Pressure is at 1.5 to 6 Bar) and water supply switch shall be mounted near the ice machine. Inlet pipeline shall be of independent type and drainage outlet shall be also not far from the ice machine. Two separate water drainage pipelines shall be required for draining the ice machine and the ice storage bin. The ice machine shall not be placed in an airproof environment, next to heat sources, or outdoors. To ensure ice quality, personnel responsible for installation shall be consulted about whether or not water filter or processor shall be installed according to user s local water-quality conditions. 13

2. Installation procedure The ice-maker shall be lifted using the four shackles fixed on its base plate (for small-sized machine) or on its top (for large-sized machine) and shall be laid down slowly on the support or ice storage bin that has been put in place. For large-sized ice-maker, the correct steel cable lifting is as shown in this figure. CORRECT LIFTING WRONG LIFTING OPERATION 1. Preliminary Checks a) Is machine levelled? b) Are voltage and frequency of mains supply the same as indicated on rating plate? c) Is drainage system working properly? Minimum value Maximum value Ambient temperature 5º 40º Water temperature 5º 35º Water pressure 1,5kg/cm2 5kg/cm2 Desviation from voltage rating -10% 6% NOTE: To install a pressure reducer If water inlet pressure is more than 6 Bar. ATENTION: Check that voltage and mains frequency is the same as in the rating plate. 2. Starting up Open feed water valve and fill up the water tank, and the floating valve automatically closes when water level reaches the spillover port. During trial operation, pneumatic mains switch (K1) shall be turned to ON, then the power indicator on the panel of electrical box (see Figure 5). Switch on the Start/Stop button on the electrical cabinet to enable the ice-maker to enter a 3-minute-delay state (indicator of Start Delay blinks) which is followed by the automatic start of gear box and water pump by the control system, and then the machine goes into operation. Observation shall be conducted at this time to verify that (1) ice blade is rotating in correct direction or the shaft and rotation is in normal status; (2) water dispensing disc is aligned with the red mark and water-dispensing pipes have normal output. In case above-stated items are all in normal operation, the Start/Stop button shall be switched off to stop the ice machine. (3) Ice production stage: Start refrigeration system and open return air valve and Freon feed valve. 14

3. Stop When the Start/Stop button is switched off, water pump and solenoid valve stop working immediately, and the gear box stops working too after a 3-minute delay so as to remove the ice left on the interior of the vaporization cylinder. Now the pneumatic switch shall not be turned off before being delayed for 3 minutes. Stoppage due to alarm Stoppage due to ice full level alarm (normal stop): When microprocessor of computer s main board detects full level of ice storage tank, the programmed process of ice full level shall be implemented: water pump and solenoid valves stop first, and then gear box motor stops after 3-minute delay and ice full level indicator turns on at the same time. Now the system is in stand-by mode. After ice is discharged, the system automatically restore to normal operating status: gear box motor, water pump and solenoid valve will be started in sequence. IMPORTANT! ADVISE THE FINAL USER ON MAINTENANCE PROCEDURES WHICH ARE NOT INCLUDED IN WARRANTY, AS WELL AS THOSE BREAKDOWNS CAUSED BY NEGLECT OF PROPER MAINTENANCE PROCEDURES. MAINTENANCE AND CLEANING INSTRUCTIONS IMPORTANT! **Maintenance and cleaning procedures as well as problems derived from failing to carry them out are not covered by the warranty. Proper maintenance is essential to obtain favourable ice quality and optimum functioning of unit. Frequency depends on water quality and characteristics of room where unit is installed. ** Maintenance/cleaning procedures should take place at least once every six months. If concentration of air pollutants is high, complete procedures on a monthly basis. Important Maintenance for Removable Electromagnetic Valve (See Figure9 and Figure10) 1. During the preliminary stage of ice production (Approx one-week or one month), cleaning for Electromagnetic valve shall be carried out by well-trained (or professional) maintenance staff to avoid solenoid core, fore-guide valve hole and piston from being block or stuck. Before dismantling and cleaning the solenoid s pipeline, the refrigerant in it shall be completely discharged. 2. Tap water quality shall be guaranteed and periodic cleaning shall be carried out for water tank and feed water pipelines to ensure smooth access of water system, and all pipe fittings shall be free of leak. 3. Regular inspection shall be carried on the level of water dispensing pan, which shall be in line with the red mark, and can be regulated by the water valve beside the water dispersing pan, and on the status of water outflow to prevent water from dripping into ice storage tank or ice conveying system. 4. Regular inspection shall be conducted on the connections to verify they are not loose or dummy connections, and earth wire is fixed, insulation of electrical parts not damaged. 5. Frequent inspection on refrigeration pipelines and valves shall be conducted to identify their leakages and loosing or leaking at flange fittings. 6. Good housekeeping shall be maintained for main parts of ice machine like gear box and control cabinet 7. Regular inspection on ice blade spacing shall be conducted. Too big spacing between ice blades will affect the removal of ice. 8. Lube oil for gear box shall be checked and changed on a regular basis 9. Maintenance and use of valves. Regular application of rustproof oil shall be carried out on surface of valve rod and lock nuts to ensure smooth diverting and keep valve rod and seal free of damag. 15

TROUBLESHOOTING Fault Description Possible Causes Recommendations Machine inactive (1) Power indicator not on (2) Ice full level indicator on (3) low water level indicator on Ice production decreases Main switch is set to OFF position Connection wire get loosened Malfunction of ice level control assembly Blocked filters Low water pressure Regulation valve partially blocked or improperly adjusted Low water level of water bin Knob selector need to be set to ON position Check the wiring Clean or replace ice level control assembly Please refer to recommendations for low water level alarm Clean or replace filters Adjust or replace float valve Adjust float valve to set water level Ice machine in operation but no ice produced Insufficient feed of refrigerant No water production Identify gas leakage and make a refrigerant load in water cylinder for ice Check water pump operation or replace it Noise of gear box is too high Gear box motor gets stuck Gear box damaged or leaks lubrication oil Gear box s bearing and teeth get worn out Check or replace it Check or replace it

87