EPCE03-06D. The Next Generation of Air Conditioning Systems

Similar documents
. Creating Maximum Comfort

Daikin Airconditioning UK Ltd

MOV75984_EPCE02-18 Page 1 8-OCT-02 S Y S T E M S

EDUS D Engineering Data. Design Manual RWEQ-TATJU, 208 / 230 V RWEQ-TAYDU, 460 V RWEQ-TAYCU, 575 V. Heat Pump 60 Hz Heat Recovery 60 Hz

NFZP Variable Refrigerant Flow Guide Specification

VRV HEAT RECOVERY

VRV IV S-series heat pump

ENERGY-INTELLIGENT TECHNOLOGY HEATING AND COOLING SYSTEMS 5.16 LIGHT COMMERCIAL RESIDENTIAL AIR COOLED RENOVATION NEW CONSTRUCTION

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group

VRV systems. Superior heating under low temperature conditions

Water cooled VRV IV W-series

3 rd Generation of VRV. The professional solution for your professional project

The Multi-talented VRV-S.

VRF Series. The most advanced commercial air conditioning system

VRV LIFE FLEXIBLE / DUAL-FUEL HEATING / INVERTER TECHNOLOGY / QUIET / SPACE-SAVING

Product. ortfolio. Integrated climate control

Product. ortfolio. Integrated climate control

w w w. d a i k i n. e u ATXS-E

your comfort. our world. Altherma Flex Type Renewable heat pump system for every environment

SiE Service Manual. RXYQ5-48MAY1 R410A Heat Pump 50Hz

January Engineering Data RXSQ24-60TAVJU. Heat Pump 208/230V / 60 Hz / 1 ph. Presales Manual DAIKIN NORTH AMERICA LLC

MULTI SYSTEM SHOPS RESTAURANTS SMALL OFFICES COMMERCIAL MULTI SYSTEM.

Daikin air conditioners for your home

Daikin air conditioners for your home, shops, restaurants and offices

Replacement VRV Quick & quality replacement for R-22 and R-407C systems

EPCE00-10B. Powerful. air cooled. Hydronic systems EUWA*40-200K(A)X

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FXMQ-MB

EDUS D Engineering Data RXYQ-TAYCU, 575 V. Heat Pump 60 Hz

DAIKIN Modular Inverter Air Cooled Chiller

W SERIES. PCVMT1603aprv WATER COOLED SYSTEM. Cooling Only 50 Hz

Here is the common bond that can put it all together.

VRV The total solution. Integrated Climate Control

mini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS

PCV0915. Cooling Only 50 Hz Heat Pump 50 Hz/60 Hz. A system with the high capacity needed to suit large-sized buildings

SiUS RXYQ72, 96, 144, 168, 192MTJU R-410A Heat Pump 60Hz RXYQ72MTJU RXYQ96MTJU RXYQ144MTJU RXYQ168MTJU RXYQ192MTJU

PCV0915. Cooling Only 50 Hz Heat Pump 50 Hz/60 Hz. A system with the high capacity needed to suit large-sized buildings

Ultimate VRF System R410A, 50Hz

Keep looking you ll never find me. VRV IV heat pumps for indoor installation

SECTION VARIABLE REFRIGERANT VOLUME (VRV) HVAC SYSTEM

E 1E. small offices and shops. The ideal air conditioning system for. 5S+1E concepts of

DC Inverter Smart VRF Products(R410A)

technical data air conditioning systems RZQ-B Pair/Twin/Triple/Double Twin Application, Inverter Controlled Unit Split Sky Air

MRVIII-C MRVIII-C. 4 way air return heat exchanger design. Two stages heat exchanger design. Double EEV design. Special Heat Exchanger Design

COMMERCIAL AIR CONDITIONERS. R410A All DC Inverter VRF V5 X Series 50/60Hz

PCV1217. Cooling Only 50 Hz Heat Pump 50 Hz/60 Hz. A system with the high capacity needed to suit large-sized buildings

Daikin air conditioners for your home

VRV IV i-series heat pump

VRV IV heat recovery Best efficiency and comfort solution

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

OUTDOOR UNITS Air-Cooled VRV REYQ8-48P8Y1B 140 RXYQ5-54P7W1B(A) 142 RXYQ16-36P7W1B 144 RXYSQ4-6PA7Y1B 145 RXYSQ4-6PA7V1B 146 RXQ5-18P7W1B(A) 147

V4 Plus Heat Recovery VRF. Linda Lin Pre-sales Engineer

OUTDOOR UNITS Air-Cooled VRV REYQ8-48P8Y1B 128 RXYQ5-54P7W1B(A) 130 RXYQ16-36P7W1B 132 RXYSQ4-6PA7Y1B 133 RXYSQ4-6PA7V1B 134 RXQ5-18P7W1B(A) 135

VRV, INTEGRATED CLIMATE CONTROL FOR MEDIUM TO LARGE COMMERCIAL SPACES

VRV, integrated climate control. for medium to large commercial spaces

Product Line Introduction. Karl Zhang Technical support engineer

For small and medium-sized food retailers. Conveni-Pack. The integrated solution for refrigeration, heating and air conditioning

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

technical data air conditioning systems FDXS-CVMB Concealed Ceiling, Inverter Controlled Unit Split Sky Air

Variable Refrigerant Flow

AIR CONDITIONERS, HEATING & COOLING for your home

technical data air conditioning systems FDKS-CVMB Concealed ceiling, Inverter Controlled Unit Split Sky Air

Daikin air conditioners for small rooms in multi application

for your home FLXS-B Flexi type unit air to air heat pumps

PRODUCT LINEUP VRF. For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL

Commercial Air Conditioners 2017/2018. VRF 50/60Hz. V5 X Series

FACT SHEET 9 Large Air-Conditioning (air-to-air)

Inverter Wall Mounted Series

VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG

for small rooms in multi application

Air Conditioning. Technical Data. Pair, Twin, triple, double twin EEDEN RZQ-C

LV Series. SEER 15+ Concealed Built in Heat Pump

Daikin air conditioners for your home

Compact design & easy maintenance

Leading edge reverse cycle air conditioning. Ducted and ceiling cassette

Compact Design For Light Commercial Buildings. Benefit Points SMALL OFFICES HOTELS NEW SHOPS, RESTAURANTS. 1. Compact & Quiet design

Ceiling Mounted Cassette ( Round Flow with Sensing ) Type

Daikin air conditioners for small rooms in multi application

THE HEAT PUMP CHOICE OF PROFESSIONALS

Split Type Air Conditioners FTNE-M Series Cooling Only [50 Hz]

Air Conditioners Heating & Cooling

TABLE OF CONTENTS RMXS-E8V1B

Modular Air Cooled Scroll Chillers

Commercial Air Conditioners VRF 50Hz V4+K/V4+S/V4+R/V4+W/V4+I/Mini VRF

NEW DAIKIN FTQ SERIES HEATING AND COOLING SYSTEMS. MULTI-POSITIONAL AIR HANDLER Up to 16 SEER / Up to 10.4 HSPF / Up to 12.5 EER

Air conditioners, heating & cooling. for large spaces. air to air heat pumps. FDQ-B

Air Conditioning System

FTQ SERIES DUCTED HEAT PUMP SYSTEMS. INDOOR AND OUTDOOR UNITS Up to 20 SEER / Up to 12 HSPF / Up to 14.5 EER INVERTER, VARIABLE SPEED COMPRESSOR

TVR 5G GUIDE SPECS. TVR 5G GUIDE SPECS - JUL.2014 Page 1

SiENBE Service Manual. RXYSQ4-5-6PA7Y1B, PA7V1B R-410A HEAT Pump 50Hz

PCVAU0828B WATER COOLED INVERTER SERIES. HEAT PUMP 50 Hz HEAT RECOVERY 50 Hz

EEDEN technical data ERHQ AA

Air Conditioners Heating & Cooling

ROOFTOP PACKAGED AIR CONDITIONERS

FACT SHEET 9 Large Air-Conditioning (air-to-air)

-20 C 11 HSPF 23 SEER WALL-MOUNTED HEAT PUMPS. 10 years* *See details on the back SINGLE ZONE MULTI-ZONE (UP TO 5 ZONES) descair.

Hybrid VRF Next Generation 2-Pipe Heat Recovery Systems

Screw Compressors ESM Fixed Speed & VS Variable Speed

Air Conditioning Product Brochure 2015/2016. Classic Series Hi-Wall Split Systems. Everyday Cool

Direct Drive Truck Units. A complete line of refrigeration units for a wide variety of vehicle chassis and applications.

Transcription:

EPCE03-06D The Next Generation of Air Conditioning Systems

T a b l e o f TC O N T E N T S

INTRODUCTION Who is Daikin? p 4 The history of VRV systems p 6 WHAT IS? p 8 THE INTELLIGENT AIR CONDITIONING SYSTEM p 10 PRODUCT EXPLANATION p 12 Possible indoor units using R-410A p 14 Possible outdoor units using R-410A p 15 Main Features p 16 A Creating maximum comfort p 16 B Energy efficient solution p 18 C High reliability p 21 D Eco friendly p 23 E Easy and flexible design p 24 F Simple and rapid installation p 27 NEW NEW PRODUCT FEATURES OUTDOOR UNITS USING R-410A p 32 Survey outdoor units p 33 technology p 34 cooling only p 37 heat pump p 38 heat recovery p 40 technology p 42 heat pump / heat recovery p 43 Accessories p 44 PRODUCT FEATURES INDOOR UNITS USING R-410A p 46 Survey indoor units p 47 FXZQ 4-way blow ceiling mounted cassette (600mm x 600mm) p 48 FXFQ 4-way blow ceiling mounted cassette p 50 FXCQ 2-way blow ceiling mounted cassette p 52 FXKQ ceiling mounted corner cassette p 54 FXDQ concealed ceiling unit (small) p 56 FXDQ-N slim concealed ceiling unit p 58 FXSQ concealed ceiling unit p 60 FXMQ concealed ceiling unit (large) p 62 FXAQ wall mounted unit p 64 FXUQ 4-way blow ceiling suspended unit p 66 FXHQ ceiling suspended unit p 68 FXLQ floor standing unit p 70 FXNQ concealed floor standing unit p 70 NEW NEW PRODUCT FEATURES CONTROL SYSTEMS p 72 Survey control systems p 73 Individual control systems p 74 Centralised control systems p 76 p 77 p 78 p 80 p 81 Accessories p 82 page 3

IIntroduction Who is Daikin? Daikin has more than 70 years experience in manufacturing advanced, high quality equipment air conditioning for residential, commercial and industrial applications. The Japanese mother company Daikin Industries Ltd. is actively engaged in research into a wide spectrum of science and disciplines, from mechanics and electronics to chemicals and fluorocarbons. Since its formation in 1972, Daikin Europe has evolved from a component assembly plant into the most advanced air conditioning manufacturing complex in Europe. All European standards regarding production, health and safety are met in full. The environment Daikin s unique position as a manufacturer of both fluoro carbon refrigerants and air conditioning and refrigeration equipment has not surprisingly led to its close involvement in environmental issues. Once ozone depletion in the stratosphere became attributable to chloro fluoro carbon refrigerant chemicals (CFCs), Daikin took the decision to cease both their production and that of the products that use them. At the same time, Daikin joined leading world manufacturers in the research into safe and environmentally friendly alternatives. The Environment Protection Agency of the U.S.A afforded recognition of these efforts in June 2002 by presenting Daikin with its prestigious trophy for the protection of the environment. Daikin intends to become a leader in the provision of environmentally friendly products. This challenge demands the eco-design and development of a comprehensive product range and an energy management system that addresses energy conservation, reduction in waste and the control of hazardous substances etc. page 4

ISO14001 ISO14001 assures an effective environmental management system in order to help protect human health and the environment from the potential impact of our activities, products and services and to assist in maintaining and improving the quality of the environment. The European affiliate companies have plans to achieve ISO 14001 by the year 2005, thereby contributing to Daikin s target of global status as a leading environment conscious company. Economic benefits will surely follow the efforts and investments needed to be a sustainable and socially responsible enterprise. ISO9001 Daikin Europe N.V. is approved by LRQA for its Quality Management System in accordance with the ISO9001 standard. ISO9001 pertains to quality assurance regarding design, development, manufacturing as well as to services related to the product. CE Daikin units comply with the European regulations that guarantee the safety of the product. Distribution network Daikin maintains close contact with its markets through a highly professional network of local distributors. Perceived as an extension of the company s quality chain, all distributors are carefully trained in order to maintain high quality sales, installation and after sales service to their customers. Quality The application of advanced technologies, combined with careful selection of bought in components and extensive in house testing and field trial procedures ensures unrivalled product quality. Training The Daikin training centre in Ostend is unique and the most advanced of its kind in Europe. Both hands on and theoretical instruction are provided into all aspects of the company s air conditioning equipment and systems and specially conceived courses are available to suit distributors and their approved dealers from all over Europe. page 5

TThe History of Systems 1987 The original VRV air conditioning system developed by Daikin in 1982 is introduced into Europe in Standard format. The system is able to supply conditioned air from up to 4 indoor units connected to a single outdoor unit. 1990 The end of the year sees the launch of the new Inverter system with the facility to operate up to 8 indoor units from a single outdoor unit. Inverter capacity control greatly increases system flexibility and efficiency. 1991 A further step forward is taken in 1991 with the introduction of the Heat Recovery system, offering simultaneous cooling and heating from different indoor units on the same refrigeration circuit. 1992 Continuous improvements to energy efficiency and system flexibility lead to the development of the advanced in which fresh air supply (HRV) and computerised management (DACMS) are integrated with the VRV. 1994 Consistent high quality and efficiency lead to the widespread acceptance of the VRV concept and Daikin becomes the first Japanese air conditioning manufacturer to be awarded the ISO9001 certification. But the search for improved flexibility and energy efficiency does not stop there. Unrivalled field experience and close regard for market requirements enables Daikin to apply yet another quantum leap to VRV technology - the Inverter-H series, operating up to 16 indoor units from just 1 outdoor unit! 1998 In anticipation of phase out dates for all CFC based equipment, Daikin Europe steps up the production of VRV air conditioning units using ozone friendly refrigerant. Daikin Europe celebrates its 25 th anniversary with the award of an ISO14001 environmental certificate and the introduction of Inverter K series with R-407C, in cooling only or heat pump format. As many as 16 indoor units can be connected to 1 single outdoor unit. page 6

1999 The series using R-22 has been designed around leading edge technologies to accommodate high capacity air conditioning networks of up to 30 indoor units from a single refrigerant circuit. Another step forward has been taken with the launch of the heat recovery series using R-407C and connecting up to 16 indoor units to 1 single outdoor unit. 2000 Because of the growing needs of large-capacity systems Daikin Europe introduces the series using ozone friendly refrigerant, in heat pump format. Up to 32 indoor units can be connected to a single refrigerant circuit. 2001 The latest addition to the VRV Plus series is the heat recovery series using R-407C. Up to 32 indoor units can be connected to a single refrigerant circuit. 2002 Daikin launches the new series an environmental friendly, energy saving series with high COP levels and flexible design characteristics. 2003 Daikin Europe has achieved a quantum leap forward in commercial air conditioning technology by the introduction of its, the world s first R-410A operated variable refrigerant flow system. Available in cooling only, heat pump and heat recovery versions, the new system, which represents a considerable advance over earlier VRV systems, demonstrates Daikin s innovative application of new technology and the latest HFC refrigerants to its VRV product programmes. No less than 40 indoor units in heat recovery as well as heat pump format can be connected to a single refrigerant circuit. 2004 The introduction of the series extends VRV operating scope into the light commercial sectors. Available in 4, 5 and 6HP capacities, the system is designed for installation in up to 9 rooms. 2005 Daikin has extended the operational scope of its acclaimed VRVII inverter driven dx air conditioning system, with a new water-cooled version, VRV-WII. Available in 10, 20 and 30HP models, the system operates on R-410A refrigerant and is available in both heat pump and heat recovery versions. page 7

W W h a t i s?

In recent years, design styles for intelligent buildings such as hotels, banks and offices etc. have increasingly featured large areas of glazing with attendant high solar heat gains that can only be dissipated by means of air conditioning. Not surprisingly therefore, air conditioning has grown in importance and is now widely accepted as an integral component of most modern architectural concepts. The increasing use of electronic office equipment raises thermal loadings still further to a point whereby, even in winter, internal temperatures can reach uncomfortable levels. The demand for cooling or heating can also vary considerably through-out the day depending on the number and occupation of personnel on the premises. But end users have come to expect far more than just cooling and heating from their air conditioning. The ideal modern system must be energy efficient, easy to install, flexible, reliable and user friendly. Fresh air must be supplied without increasing energy consumption and the role of central management facilities should also be considered in this respect for medium to large sized buildings. The Daikin Hi-VRV system meets all these demands. AIR CONDITIONING VENTILATION DAIKIN NETWORK SOLUTION CONTROL AND MANAGEMENT The innovative Hi-VRV selection programme, Daikin s flag ship software package, enables you to exploit the system s possibilities to the max and guarantees the end user a perfect service. From now on you can fully plan your Daikin air-conditioning project on a step-by-step basis without difficulty. page 9

TThe Intelligent Air Conditioning System Heat Reclaim Ventilation heat and humidity are exchanged between supply and exhaust air, which brings outdoor air close to indoor air conditions recovers energy loss realises considerable reduction of air conditioning capacity page 10

Variable Refrigerant Volume available in cooling only, heat pump and heat recovery formats. a rapid response system in which up to 40 indoor units can operate on the same refrigerant circuit. an inverter driven compressor enables the output of the outdoor unit to be modulated in accordance with the cooling/heating demand of the zone which it controls. DAIKIN NETWORK SOLUTION NEW The ideal solution for control and management of up to 2,000 indoor units. Allows detailed and easy monitoring and operation of VRV systems (maximum 2x64 control groups). The ideal solution for control and management of maximum 1,024 VRV indoor units. LONWORKS networks compatible gateway. Integrated control system connecting VRV system with BMS system. page 11

P P r o d u c t E X P L A N A T I O N

INVERTER COOLING ONLY For cooling operation from one system Up to 16 indoor units can be operated from a single outdoor unit without the need for an additional adapter PCB. The line-up of 5, 8, 10hp models is ideally suited to applications in smaller facilities and minor expansions and upgrades. / INVERTER HEAT PUMP For either cooling or heating operation from one system Up to 40 indoor units can be operated from a VRVII single outdoor unit (32 indoor units for VRV-WII) without the need for an additional adapter PCB. An extensive capacity range starting at 5hp, then from 8hp to 48hp in 2hp increments, for VRVII (10hp, 20hp & 30hp for VRV-WII), meets all customer requirements concerning small to large buildings, whether new or existing / HEAT RECOVERY For simultaneous cooling and heating operation from one system Up to 40 indoor units can be operated from a single outdoor unit in VRVII heat recovery format. Maximum 32 indoor units for VRV-WII. Extensive capacity range from 8hp to 48hp in 2hp increments for VRVII, (10hp, 20hp & 30hp for VRV-WII) meets all customer requirements concerning small to large buildings, whether new or existing. Heat recovery is achieved by diverting exhaust heat from indoor units in cooling mode to areas requiring heating. The BS unit switches the system between cooling and heating modes. page 13

PPossible Indoor Units Using R-410A Type 20 25 32 40 50 63 71 80 100 125 200 250 4-way blow ceiling mounted cassette (600mm x 600mm) FXZQ 4-way blow ceiling mounted cassette FXFQ 2-way blow ceiling mounted cassette FXCQ Ceiling mounted corner cassette FXKQ Concealed ceiling unit (small) FXDQ Slim concealed ceiling unit FXDQ-N Concealed ceiling unit FXSQ Concealed ceiling unit (large) FXMQ Wall mounted unit FXAQ 4-way blow ceiling suspended unit FXUQ Ceiling suspended unit FXHQ Floor standing unit FXLQ Concealed floor standing unit FXNQ page 14

cooling only heat pump PPossible Outdoor Units Using R-410A heat recovery N of outdoors N of compressors N of connectable indoors Minimum capacity index* Maximum capacity index* RXQ5M RXYQ5M - 1 1 8 63 163 20 RXQ8M RXYQ8M REYQ8M 1 2 13 100 260 29 RXQ10M RXYQ10M REYQ10M 1 2 16 125 325 29 - RXYQ12M REYQ12M 1 2 19 150 390 29 - RXYQ14M REYQ14M 1 3 20 175 455 35 - RXYQ16M REYQ16M 1 3 20 200 520 35 - RXYQ18M REYQ18M 2 4 20 225 585 41 - RXYQ20M REYQ20M 2 4 20 250 650 41 - RXYQ22M REYQ22M 2 4 22 275 715 41 - RXYQ24M REYQ24M 2 5 32 300 780 46 - RXYQ26M REYQ26M 2 5 32 325 845 46 - RXYQ28M REYQ28M 2 5 32 350 910 46 - RXYQ30M REYQ30M 2 6 32 375 975 51 - RXYQ32M REYQ32M 2 6 32 400 1,040 51 - RXYQ34M REYQ34M 3 7 34 425 1,105 56 - RXYQ36M REYQ36M 3 7 36 450 1,170 56 - RXYQ38M REYQ38M 3 7 38 475 1,235 56 - RXYQ40M REYQ40M 3 8 40 500 1,300 61 - RXYQ42M REYQ42M 3 8 40 525 1,365 61 - RXYQ44M REYQ44M 3 8 40 550 1,430 61 - RXYQ46M REYQ46M 3 9 40 575 1,495 68 - RXYQ48M REYQ48M 3 9 40 600 1,560 68 Capacity steps heat pump N of N of N of Minimum capacity Maximum Capacity connectable heat recovery outdoors compressors index* capacity index* steps indoors RWEYQ10M 1 1 16 125 325 * RWEYQ20M 2 2 20 250 650 * RWEYQ30M 3 3 32 375 975 * *Information was not available at time of publication INDOOR UNIT CAPACITY INDEX Model 20 25 32 40 50 63 71 80 100 125 200 250 Capacity index 20 25 31.5 40 50 62.5 71 80 100 125 200 250 eg. Selected indoor units: FXCQ25 + FXFQ100 + FXMQ200 + FXSQ40 Connection ratio: 25 + 100 + 200 + 40 = 365 possible outdoor unit RXYQ12M page 15

M M a i n F E A T U R E S AA. Creating Maximum Comfort 1 Inverter technology The linear VRV system makes use of a variable Proportional Integral (PI) control system which uses refrigerant pressure sensors to give added control over inverter and ON/OFF control compressors in order to abbreviate control steps into smaller units to provide precise control in both small and larger areas. This in turn enables individual control of up to 40 indoor units of different capacity and type at a ratio of 50~130 % in comparison with outdoor units capacity. 5 HP outdoor units use inverter control compressors only. 5HP outdoor unit 100% Compressor Capacity Control Inverter Control 210Hz-52Hz 20 Steps 24% Large Load Small 8,10,12HP outdoor unit 14,16HP outdoor unit Compressor Capacity Control 100% 14% Large N 1 Compressor Inverter Control N 2 Compressor 100% Operation Load 210Hz-52Hz + No.2 Compressor 29 Steps N 1 Compressor Inverter Control Small Compressor Capacity Control 100% 10% Large N 1 Compr. Inv. Control N 3 Compressor 100% Operation N 2 Compressor 100% Operation 210Hz-52Hz + No.2 + No.3 Compressor 35 Steps N 1 Compr. Inv. Control N 2 Compressor 100% Operation Load N 1 Compr. Inv. Control Inverter Control 210-52Hz - 20 steps Small page 16

2 Smart control brings comfort Cooling Suction air temp. VRV SERIES (DAIKIN PID Controls) ON/OFF controlled air conditioner (2.5HP) An electronic expansion valve, using PID control, continuously adjusts the refrigerant volume in respond to load variations of the indoor units. The VRV system thus maintains comfortable room temperatures at a virtually constant level, without the temperature variations typical of conventional ON/OFF control systems. Time Note: the graph shows the data, measured in a test room assuming actual heating load. The thermostat can control stable room temperature at ± 0.5 C from set point. Keeps temperature stable Slow start-up Large temperature difference Smaller temperature difference Set point Non inverter AC Startup time reduced by about 1/3 Repeats hot and cold cycles Inverter AC 3 Less frequent start/stop cycle Capacity 60% 65% 50% 55% 30 116 30+on 116+on Frequency the technique adopted by Daikin, of regulating the capacity using multiple compressors clearly results in minimum switching losses and power surges because of the overlap in capacity and frequency since Daikin utilises small 5HP inverter compressors, the influence of harmonics is less than that generated by a single large compressor the use of multiple compressors by Daikin also ensures a 50 % standby facility smaller compressors are cheaper and faster to replace page 17

BB. Energy Efficient Solution 1 Low running costs VRV systems have low running costs because it permits each zone to be controlled individually. That is, only those rooms that require air conditioning will be heated or cooled, while the system can be shut down completely in rooms where no air conditioning is required. VRV units have the highest COP/EER in the market in the most common operating area 2 Most advanced reluctance brushless DC compressor technology The scroll compressor is driven by the newly developed motor, enabling better performance, higher enery efficiency resulting in higher energy cost savings. 3 HRV - Heat Reclaim Ventilation System Heat and humidity are exchanged between supply and exhaust air, which - brings outdoor air close to indoor air conditions - recovers energy loss - realises considerable reduction of air conditioning capacity The heat exchanger modulates the humidity and temperature of incoming fresh air to match indoor conditions. The balance achieved between indoor and outdoor ambients, enables the cooling/heating load placed on the air conditioning system to be reduced. (heat and humidity are exchanged) Most energy saving solution as smaller indoor units can be selected : - size down of indoor units down to 40 % - payback total VAM system : ±2.5 years* *conditions : outside cooling conditions : 30 C / outside heating conditions : - 8 C inside cooling conditions : 24 C / inside heating conditions : 22 C ventilation per room : 150m 3 /h Ideal modular concept to cope with the fresh air requirements 4 Auto restart capability Even after exceptionally long power failures, the built-in auto restart capability ensures automatic system start up. Since the preset memory is not erased by interruptions in power supply, no programme resetting is necessary. page 18

5 Low operation sound level Continuous research by Daikin into reducing operation sound levels has resulted in the development of a purpose designed inverter scroll compressor and fan. The new grille and fan offer low noise, high volume airflow and are housed in a compact casing together with the associated compressor components. The use of this new technology assembly enables a 16hp unit to be housed in a single casing. Aero spiral fan: Bending the fan blade edge reduces turbulence, resulting in less pressure loss Aero fitting grille: New shape promotes spiral discharge airflow, resulting in reduced pressure loss Capability % 100 Night quiet function (max. -8dBA) During night time, sound level of the outdoor unit can be reduced for a certain period : starting time and ending time can be input 50 Load % 0 58 Operation sound dba 50 Night mode Max. - 8dBA(10HP) Night mode ends 8:00 12:00 16:00 20:00 0:00 4:00 8:00 Night mode starts external signal input to outdoor PCB Notes : This function is available in setting at site. The relationship of outdoor temperature (load) and time shown in the graph is just an example. Water-cooled air conditioning can be acceptable in certain critical areas in which the operating sound of air-cooled air conditioning could be a little intrusive. This results from: - the low operating sound level of the condensing unit - indoor installation capabilities of the unit - custom engineered sound level of the dry cooler Daikin indoor units have very low sound operation levels, down to 25 dba. db(a) Perceived loudness Sound 0 Treshold of hearing - 20 Extremely soft Rustling leaves 40 Very soft Quiet room 60 Moderately loud Normal conversation 80 Very loud City traffic noise 100 Extremely loud Symphonic orchestra 120 Threshold of feeling Jet taking off Daikin indoor units page 19

BB. Energy Efficient Solution 6 Operation range of outdoor temperature Standard operation down to -20 C outdoor ambient temperature Advanced PI control of the outdoor unit enables VRVII heat recovery and Inverter cooling only/heat pump series to operate at outdoor ambients down to -5 C in cooling mode and down to -20 C in heating mode. 50 40 Cooling 43 CDB 50 40 Cooling 43 CDB 30 30 20 10 Heating 15.5 CWB 20 10 Cooling & Heating 15.5 CWB Heating 15.5 CWB -5-5 CDB -5-5 CDB -5 CWB -10-10 -15-15 -20-20 CWB Inverter cooling only heat pump -20 Heat recovery -20 CWB Wide operating range of the water-cooled units between 10 C & 45 C, both in cooling and heating. 50 40 Cooling 45 C Heating 45 C 30 20 10 0 10 C 10 C page 20

CC. High Reliability 1 N 1 anti-corrosion treatment Special anti corrosion treatment of the heat exchanger provides 5 to 6 times greater resistance against acid rain and salt corrosion. The provision of rust proof steel sheet on the underside of the unit gives additional protection. Improvement in corrosion resistance Corrosion resistance rating Non-treated Anti-corrosion treated Salt corrosion 1 5 to 6 Acid rain 1 5 to 6 An anti-corrosion heat exchanger cutaway view Hydrophilic film Aluminium Heat exchanger Corrosion-resistant Acrylic resin Performed tests : VDA Wechseltest contents of 1 cycle (7 days): 24 hours salt spray test SS DIN 50021 96 hours humidity cycle test KFW DIN 50017 48 hours room temperature & room humidity testing period : 5 cycles Corrosion resistance 8 6 4 2 0 1 2 3 4 5 Cycle Bare aluminium DAIKIN P.E. Kesternich test (SO2) contents of 1 cycle (48 hours) according to DIN50018 (0.21) testing period : 40 cycles Corrosion resistance 10 9 8 7 6 5 4 3 2 1 0 1 2 3 4 5 6 10 20 30 40 Cycle page 21

CC. High Reliability 2 Double back-up function In the event of a compressor malfunction, the remotely controlled or field set back-up function in the outdoor unit in question (and also between different outdoor units) will allow emergency operation of another compressor in order to maintain 8 hour maximum interim capacity 3 Duty cycling The cyclical start-up sequence of multiple outdoor unit systems equalises compressor duty and extends operating life. 4 Special oil equalising technology The incorporation of this technology ensures that the optimum quantity of oil is contained in each outdoor unit module in order to maintain compressor reliability. Automatic checks are carried out every 6 minutes on the number of compressors in operation and also to ascertain that there is enough oil to keep them running. Each compressor in a VRVII outdoor unit is equipped with an internal oil equalising circuit, comprising an oil separator and oil return circuit. This ensures that the maximum quantity of oil is returned to the compressor case before entering the REFNET piping network. page 22

DD. Eco Friendly 1 Lowest refrigerant amount in the total system 18 HP Comparable VRF system Total refrigerant amount 100% 160 % in the system* * based on average installation Reduction of 20.5% 2 Dramatic reduction in initial refrigerant charge : 16 HP R-22 R-407C R-410A VRV-K series VRV-K series series Refrigerant charge 100 % 85.6 % 79.5 % 3 Optimised R-410A design Daikin Europe has achieved a quantum leap forward in commercial air conditioning technology by the introduction of its VRVII, the world s first R-410A operated variable refrigerant flow system. Available in cooling only, heat pump and heat recovery versions, the new system, which represents a considerable advance over earlier VRV systems, demonstrates Daikin s innovative application of new technology and the latest HFC refrigerants to its VRV product programmes. 4 Less waste and improved re-cycling The lead free, soldered PCB obviates environmental contamination, whilst the recyclable galbarium steel bottom plate is designed to last around 6 times longer than the traditional galvanised base. 5 Refrigerant recovery function The refrigerant recovery function enables all expansion valves to be opened. In this way the refrigerant can be drained from the piping system and stored in the receiver and the condenser. page 23

1 Total room layout flexibility VRVII systems are easily adaptable to changes in room layout : extra indoor units can be added to a VRV outdoor unit up to a capacity level of 130%. Also, since VRVII heat recovery systems offer simultaneous cooling and heating, existing indoor and outdoor units can continue to provide year round air conditioning from their existing locations, even if office layouts are altered or extended. EE. Easy and Flexible Design Meeting room 2 Office Meeting room Reception room Stock room Complete flexibility Office Meeting room ROOM LAYOUT CHANGE INDOOR UNIT ADDITION Meeting room The VRVII / VRV-WII systems enables different floors or even rooms to be rented to different customers, because each room has independent control of its air conditioning. Thanks to inverter technology, as many as 40 indoor units (32 indoor units for VRV-WII) with different types and capacities can be installed in one system. This system automatically and effectively controls each unit to provide individual rooms of different sizes with a comfortable working or living environment. 3 Year round cooling and/or heating Designed to provide simultaneous year round cooling and/or heating, VRVII heat recovery systems are modular in concept and are therefore, ideal for use in rooms or zones that generate varying thermal loads according to building orientation or local hot or cold spots. It is possible for the same meeting room to give rise to differing thermal loads depending on the time of day, number of occupants present, location and usage pattern of lighting and electronic office equipment. Until the advent of the VRV, a complex 4-pipe fan coil was needed to meet this requirement. The VRV however, is easier to design and install and in its heat recovery format, can conserve energy in two or more rooms at the same time. The colder it is outside, the warmer it needs to be indoors, which means that the capacity of the air-cooled outdoor unit drops. Water-cooled air conditioners are not subject to this problem. The boiler ensures that sufficient enough additional heat is always available indoors. page 24

4 Longest refrigerant piping run The ability to sustain refrigerant piping in lengths up to 150m (175m equivalent), allows systems to be designed with level differences of 50m between indoor and outdoor units and 15m between individual indoor units. Thus, even with installations in 15 storey buildings, all outdoor units can be located at rooftop level. g ipin al p 0 m u t c 5 A th 1 leng Actual piping length *1 Level difference between indoor and outdoor units ing t pip alen 75 m v i u Eq th 1 leng Level difference between indoor units piping length between first branch and furthest indoor units *1 in this case the outdoor unit is located above the indoor unit. If the outdoor unit is located underneath the indoor unit the level difference is a maximum of 40m. The water-cooled VRV-WII, uses water as its heat source and since there are no limitations on water piping length, is eminently suitable for application to tall multi storey or large buildings. Considerable flexibility is available within the refrigerant circuit since up to 120m actual piping length and 50m* (if the VRV-WII is above the indoor units) in height can exist between the VRV-WII and indoor units. Water piping does not intrude on the occupied spaces, so there are no leakage problems. * 40m if the VRV-WII is below the indoor units. Actual piping length between the VRV-WII and indoor units: 120m (Equivalent piping length: 140m) Water piping Refrigerant piping (Total piping length: 300m) Level difference between indoor units: 15m Level difference between the VRV-WII and indoor units: 50m if the VRV-WII is above 40m if the VRV-WII is below Indoor installation VRV-WII Water piping length depends on the heat source equipment page 25 g ipin al p 0 m u t c 2 A th 1 leng ng pipi lent 0 m a v i Equ gth 14 len

EE. Easy and Flexible Design 5 VRV Pro selection programme A simple to use, Daikin computerised selection programme, designed for use with Windows 95, Windows 98 and WindowsNT systems, enables consulting engineers, design and build contractors, property developers and architects etc. to plan a Daikin air conditioning project on a step by step basis, complete with detailed drawings, bills of quantities and costs. The programme thus enables VRV air conditioning systems to be engineered precisely and economically (without over-sizing units), thereby ensuring optimum operating cycles and maximum energy efficiency. Features : the VRV Pro selection programme offers 3 separate modes to accommodate different design formats according to customer requirements. Multi languages are possible. 1. Expert mode : once the cooling and heating loads in the different rooms have been calculated, the software will select the most appropriate system plus an estimate of the power consumption 2. Quick mode : based on calculated system loads, the software will select the most appropriate system 3. Drawing mode : selecting the indoor and outdoor units from a list enables the user to design a system in no time at all AutoCAD and scanned drawings can be used to help draw up a floor plan piping diameters can be automatically calculated indoor and outdoor units, headers and joints etc can be automatically selected Windows95, Windows98 and WindowsNT are registered trademarks of Microsoft corporation. 6 VRV Xpress This new super rapid response VRV selection tool is easy to understand, easy to use and enables automated piping and wiring diagrams of up to 3MB to be transmitted via e mail. The package comes complete with single file software and update, requires no installation or drawings and is available in multi language options. page 26

FF. Simple and Rapid Installation 1 Short installation time Installation space (16 HP) 3.56 m 2 1.88 m 2 Thanks to small bore refrigerant pipes and REFNET piping options, the VRVII / VRV-WII piping system can be installed very easily and quickly. Installation of the VRVII / VRV-WII system can also be implemented floor by floor, so that sections of the building can be put into use very quickly, or enabling the air conditioning system to be commissioned and operated in stages, rather than on final completion of the project. RSXYP Approx. 50% reduction 2 Dramatic reduction in installation space Stacked configuration is possible. (Ceiling height) 3200mm or higher VRVII features a dramatic reduction in installation space - for example, the 16hp outdoor unit is housed in a single casing outdoor unit, providing a 50 % reduction in required installation space. The adoption of a new water heat exchanger and optimization of the refrigerant control circuit has resulted in the industry s most compact and lightweight design. The unit weight of 150kg and height of 1,000mm makes installation easy. Stacked configuration is also possible, contributing further to space savings. (Floor level) (100-300mm) 3 Modular & lightweight Modular design enables units to be joined together in rows with an outstanding degree of uniformity. The design of the outdoor units is sufficiently compact to allow them to be taken up to the top of a building in a commercial elevator, overcoming site transportation problem, particularly when outdoor units need to be installed on each floor. Reduction of 42% 10HP Weight reduction 100 % 84 % 58 % page 27

FF. Simple and Rapid Installation 4 No structural reinforcement necessary The galbarium steel allows the use of block foundations - earlier VRV K and L systems required full beam foundations. Thanks to the lightweight and vibration-free construction of the outdoor units, floors do not need to be reinforced, reducing the overall cost of the building. RSXYP10K RXYQ16M 5 Unified REFNET piping REFNET joint REFNET header REFNET joint Attached insulators for REFNET joint Attached insulators for REFNET header T-joint The unified Daikin REFNET piping system is especially designed for simple installation The use of REFNET piping in combination with electronic expansion valves, results in a dramatic reduction in imbalance in refrigerant flowing between indoor units, despite the small diameter of the piping. REFNET joints and headers (both accessories) can cut down on installation work and increase system reliability. Compared to regular T-joints, where refrigerant distribution is far from optimal, the Daikin REFNET joints have specifically been designed to optimise refrigerant flow. 6 Increased installation flexibility Duct Duct Outdoor units can be installed far back from former location. Current 7 High external static pressure : 6mm H 2 O Daikin now offers high external static pressure as standard to meet requirements of indoor installation. 8 4-way piping connection VRVII / VRV-WII series not only offer the possibility to run piping from the front, but also from the left, right or bottom, thus providing greater freedom of layout. Front Left Bottom Right page 28

9 Downsizing refrigerant piping Reduced piping diameters Use of high efficiency R-410A enables the VRVII to operate on a smaller refrigerant charge to be used, leading to a reduction in liquid and gas pipe diameters. Reduced piping costs thanks to modular design 0.51 m 2 0.29 m 2 1,700 x 300 950 x 300 based on a 240HP installation Smaller diameter liquid and gas piping contributes to a reduction in installation space and installation costs. Standard VRV System Outdoor unit Indoor units (max. 16 units) Outdoor unit System Indoor units (max. 40 units) Around 30% reduction in installation costs for refrigerant piping. System Indoor units (max. 32 units) R-410A H 2 O page 29

F F. Simple and Rapid Installation 10 Sequential start Up to 3 outdoor units can be connected to 1 power supply and can be turned on sequentially. This allows the number of breakers and their capacities to remain small and simplifies wiring (for models of 10Hp or less). 11 Self diagnosis Detects malfunctions in major locations of the system and displays the type of malfunction and location, which in turn allows servicing and maintenance to be performed more efficiently. 12 Crosswiring check The cross wiring check facility available on the VRVII is the first of its type in the industy to warn operatives of connection errors in interunit wiring and piping. This function identifies and alerts system errors by means of on/off LEDs on the outdoor unit s PC boards. 13 Simplified wiring A simple 2-wire non-shielded multiplex transmission system links each outdoor unit to multiple indoor units using one 2-core wire, thus simplifying the wiring operation. Furthermore, outdoor units have power connection outlets on side and front, resulting in easier installation and maintenance and saving space when rows of units are connected together. page 30

14 Super Wiring system A Super Wiring system is used to enable the shared use of wiring between indoor units, outdoor units and the centralised remote control. This system makes it easy for the user to retrofit the existing system with a centralised remote control, simply by connecting it to the outdoor units. Thanks to a non polarity wiring system, incorrect connections become impossible and installation time is reduced. 15 4-way wiring connection Wiring can be fed from the front panel, both left and right side panels or bottom panel of the outdoor unit. Left Right Front Bottom 16 Auto address setting function Allows wiring between indoor and outdoor units, as well as group control wiring of multiple indoor units, to be performed without the bothersome task of manually setting each address. page 31

P Product Features O U T D O O R U N I T S

SSurvey & 5-8-10 RXQ-M Inverter cooling only Units p. 37 8,10HP Inverter heat pump 5-8-10-12-14-16-18-20-22-24-26-28-30-32-34-36-38-40-42-44-46-48 RXYQ-M p. 38 12,14,16HP Heat recovery 8-10-12-14-16-18-20-22-24-26-28-30-32-34-36-38-40-42-44-46-48 REYQ-M p. 40 28,30,32HP 10-20-30 Inverter heat pump RWEYQ-M p. 43 10HP 10-20-30 Heat recovery RWEYQ-M p. 43 10HP All VRVII units have standard treatment against corrosion(*). (*) Note: for extremely corrosive environmental conditions, additional precautions have to be taken. page 33

Technology Iron Neodymium Magnet Low pressure side N S S N N S S High pressure side N N S Rotating Stator Field Normal torque Reluctance torque Suction Scroll Discharge Reluctance DC Motor 1 Reluctance brushless DC compressor The reluctance brushless DC motor provides significant increases in efficiency compared to conventional AC inverter motors, simultaneously using 2 different forms of torque (normal and reluctance torque) to produce extra power from small electric currents. The motor comprises powerful neodymium magnets, that create the reluctance torque. These magnets are approximately 12 times stronger than ferrite magnets and make a major contribution to its energy saving characteristics. Ferrite magnet Neodymium magnet NEW High thrust mechanism (VRVII cooling only/heat pump) By introducing high pressure oil, the reactive force from the fixed scroll is added to the internal force, thereby reducing thrust losses. This results in improved efficiency and suppressed sound level 2 Sine Wave DC inverter Optimizing the sine wave curve, results in smoother motor rotation and improved motor efficiency. DC fan motor structure 3 DC fan motor The use of a DC fan motor offers substantial improvements in operating efficiency compared to conventional AC motors, especially during low speed rotation. DC motor efficiency (comparison with a conventional AC motor) 100 80 Efficiency (%) 60 40 20 AC motor page 34 0 200 300 400 500 600 700 800 900 1000 Motor speed (rpm)

4 Aero fitting grille & aero spiral fan These features achieve a low noise fan with a large airflow, and realize a compact casing together with the compressor linking technology. Aero spiral fan Bending the fan blade edge reduces turbulence, resulting in less pressure loss. Aero fitting grille New shape promotes a spiral discharge airflow, resulting in reduced pressure loss. 5 e-pass heat exchanger Optimization of the path layout of the heat exchanger prevents heat transferring from the overheated gas section towards the sub cooled liquid section - a more efficient use of the heat exchanger. Current Model HD Type OUT 45 C IN 85 C IN 85 C 27 C 55 C 55 C 27 C 37 C 27 C 55 C 27 C 27 C 50 C 27 C OUT 45 C 43 C 60 C 55 C OUT 45 C 4 In cooling mode, the heat exchanger of the condensor is improved. This means an improvement of COP by 3%. 7 5 1 2 6 i-demand function The newly introduced current sensor minimizes the difference between the actual power consumption and the predefined power consumption. Power consumption (KVV) 8:00 12:00 16:00 20:00 Time No oil equalising piping necessary for VRVII cooling only / heat pump series 7 Compact aero box Lower noise and savings in input power are achieved by stacking the inverter and control PCBs within a new and more compact aero box. page 35

Line-up 5HP 8-10HP 12-14-16HP 18-20HP 34-36HP 22-24-26HP 38-40-42HP 28-30-32HP 44-46-48HP page 36

COOLING ONLY XQ-M9 VRVII COOLING ONLY RXQ5M9W1B RXQ8M9W1B RXQ10M9W1B Equivalent horsepower Number of outdoor units Number of connectable indoor units Minimum capacity index Maximum capacity index Capacity steps Nominal cooling capacity Power input COP Power supply Dimensions Height mm Width Depth Weight kg Colour Sound pressure levels db(a) Sound power level db(a) Fan Type Air flow rate m 3 /h Refrigerant Name Charge kg Control Refrigerant oil Type Charge l Compressor Type Number of compressors Starting method Piping connections Liquid mm Gas mm Safety devices HP kw kw W1 mm mm NEW 5 8 10 1 1 1 8 13 16 62.5 100 125 162.5 260 325 20 29 29 14.0 22.4 28.0 4.14 5.92 8.01 3.38 3.78 3.50 3N~, 50Hz, 400V 1,600 1,600 1,600 635 930 930 765 765 765 141 219 219 ivory white 54 57 58 72 78 78 propeller fan 4,500 10,500 10,800 R-410A 5.6 7.6 8.6 electronic expansion valve synthetic (ether) oil 1.7 1.6+1.7+2 1.6+1.7+2 hermetically sealed scroll type 1 2 2 direct on line 9.5 fl 9.5 fl 9.5 fl 15.9 fl 19.1 br 22.2 br high pressure switch, fan motor driver overload protector, inverter overload protector, overcurrent relay (for 8, 10HP), PCB fuse Notes: Nominal cooling capacities are based on: indoor temperature: 27 CDB, 19 CWB outdoor temperature: 35 CDB equivalent refrigerant piping: 7.5m level difference: 0m Sound power level is an absolute value that a sound source generates. Sound pressure level is a relative value, depending on the distance and acoustic environment. Sound values are measured in a semi-anechoic room. page 37

NEW HEAT PUMP VRVII HEAT PUMP RXYQ5M9W1B RXYQ8M9W1B RXYQ10M9W1B RXYQ12M9W1B RXYQ14M9W1B RXYQ16M9W1B Nominal cooling capacity kw Nominal heating capacity kw Power input Cooling kw Heating kw COP Cooling Heating Power supply W1 Dimensions Height mm Width mm Depth mm Weight kg Colour Sound pressure levels db(a) Sound power level db(a) Fan Type Air flow rate Refrigerant Name Charge kg Control Refrigerant oil Type Charge l Compressor Type Starting method Piping connections Liquid mm Gas mm Safety devices RXYQ-M9 page 38 14.0 22.4 28.0 33.5 40.0 45.00 16.0 25.0 31.5 37.5 45.0 50.0 4.14 5.92 8.01 9.16 13.40 16.00 3.71 6.06 7.65 9.20 11.70 13.20 3.38 3.78 3.50 3.66 2.99 2.78 4.31 4.13 4.12 4.08 3.85 3.79 3N~, 50Hz, 400V 1,600 1,600 1,600 1,600 1,600 1,600 635 930 930 1,240 1,240 1,240 765 765 765 765 765 765 146 217 217 240 289 289 ivory white 54 57 58 60 60 60 72 78 78 80 80 80 propeller fan 4,500 10,500 10,800 12,600 12,600 12,600 R-410A 5.6 7.6 8.6 10.4 11.6 12.4 electronic expansion valve synthetic (ether) oil 1.7 1.6+1.7+2 1.6+1.7+2 1.6+1.7+2 1.7+(2x1.6)+3.2 1.7+(2x1.6)+3.2 hermetically sealed scroll type direct on line 9.5 fl 9.5 fl 9.5 fl 12.7 fl 12.7 fl 12.7 fl 15.9 fl 19.1 br 22.2 br 28.6 br 28.6 br 28.6 br high pressure switch, fan motor driver overload protector, inverter overload protector, overcurrent relay (for 8-16HP), PCB fuse Notes: Nominal cooling capacities are based on: indoor temperature: 27 CDB, 19 CWB outdoor temperature: 35 CDB equivalent refrigerant piping: 7.5m level difference: 0m Nominal heating capacities are based on: indoor temperature: 20 CDB outdoor temperature: 7 CDB/6 CWB equivalent refrigerant piping: 7.5m level difference: 0m Sound power level is an absolute value that a sound source generates. Sound pressure level is a relative value, depending on the distance and acoustic environment. Sound values are measured in a semi-anechoic room. RXYQ-M9 5 8 10 12 14 16 18 20 Modules RXYQ5M RXYQ8M RXYQ10M RXYQ12M RXYQ14M RXYQ16M Equivalent horsepower HP Number of outdoor units Number of compressors Number of connectable indoor units Minimum capacity index Maximum capacity index Cooling capacity kw Heating capacity kw Power input Cooling kw Heating kw COP Cooling Heating Capacity steps Dimensions Height mm Width mm Depth mm Weight kg 1 1 1 1 1 2 1 1 1 5 8 10 12 14 16 18 20 1 1 1 1 1 1 2 2 1 2 2 2 3 3 4 4 8 13 16 19 20 20 20 20 62.5 100 125 150 175 200 225 250 162.5 260 325 390 455 520 585 650 14.0 22.4 28.0 33.5 40.0 44.5 50.4 56.0 16.0 25.0 31.5 37.5 45.0 50.0 56.5 63.0 4.14 5.92 8.01 9.16 13.40 16.00 13.93 16.02 3.71 6.06 7.65 9.20 11.70 13.20 13.71 15.30 3.38 3.78 3.50 3.66 2.99 2.78 3.62 3.50 4.31 4.13 4.12 4.08 3.85 3.79 4.12 4.12 20 29 29 29 35 35 41 41 1,600 1,600 1,600 1,600 1,600 1,600 1,600 1,600 635 930 930 1,240 1,240 1,240 1,860 1,860 765 765 765 765 765 765 765 765 146 217 217 240 289 289 434 434

RXYQ-M9 22 24 26 28 30 32 34 36 38 40 42 44 46 48 1 1 1 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 2 2 2 3 22 24 26 28 30 32 34 36 38 40 42 44 46 48 2 2 2 2 2 2 3 3 3 3 3 3 3 3 4 5 5 5 6 6 7 7 7 8 8 8 9 9 22 32 32 32 32 32 34 36 38 40 40 40 40 40 275 300 325 350 375 400 425 450 475 500 525 550 575 600 715 780 845 910 975 1,040 1,105 1,170 1,235 1,300 1,365 1,430 1,495 1,560 61.5 68.0 72.5 78.0 84.5 89.0 96.0 101 106.0 113 117.0 123 129.0 134 69.0 76.5 81.5 87.5 95.0 100.0 108.0 113.0 119.0 127 132 138 145.0 150.0 17.20 21.40 24.00 25.20 29.40 32.00 29.40 32.00 33.20 37.40 40.00 41.20 45.40 48.00 16.90 19.40 20.90 22.40 24.90 26.40 27.00 28.50 30.10 32.60 34.10 35.60 38.10 39.60 3.58 3.18 3.04 3.12 2.89 2.81 3.27 3.16 3.21 3.02 2.95 3.00 2.86 2.81 4.08 3.94 3.90 3.91 3.82 3.79 4.00 3.96 3.95 3.88 3.86 3.86 3.81 3.79 41 46 46 46 51 51 56 56 56 61 61 61 68 68 1,600 1,600 1,600 1,600 1,600 1,600 1,600 1,600 1,600 1,600 1,600 1,600 1,600 1,600 2,170 2,170 2,170 2,480 2,480 2,480 3,100 3,100 3,410 3,410 3,410 3,720 3,720 3,720 765 765 765 765 765 765 765 765 765 765 765 765 765 765 457 506 506 529 578 578 723 723 746 795 795 818 867 867 page 39

HEAT RECOVERY REYQ-M7W1B 8 10 12 14 16 Nominal cooling capacity kw Nominal heating capacity kw Power input Cooling kw Heating kw COP Cooling Heating Power supply W1 Dimensions Height mm Width mm Depth mm Weight kg Colour Sound pressure levels db(a) Sound power level db(a) Fan Type Air flow rate Refrigerant Name Charge kg Control Refrigerant oil Type Charge l Compressor Type Starting method Piping connections Liquid mm Gas mm Discharge gas mm Safety devices REYQ-M7 page 40 22.4 28.0 33.5 40.0 44.5 25.0 31.5 37.5 45.0 50.0 6.97 9.00 10.60 14.24 15.60 6.89 9.31 10.80 12.90 14.0 3.21 3.11 3.16 2.81 2.85 3.63 3.38 3.47 3.49 3.57 3~, 50Hz, 380-415V 1,600 1,600 1,600 1,600 1,600 930 930 1,240 1,240 1,240 765 765 765 765 765 245 245 295 340 340 ivory white (5Y7.5/1) 57 58 60 60 60 78 78 80 80 80 propeller fan 10,500 10,800 12,600 12,600 12,600 R-410A 10.3 11.4 12.4 13.5 14.6 electronic expansion valve synthetic (ether) oil 1.9+1.6 1.9+1.6 1.9+1.6 1.9+1.6+1.6 1.9+1.6+1.6 hermetically sealed scroll type direct on line 9.5 fl 9.5 fl 12.7 fl 12.7 fl 12.7 fl 19.1 br 22.2 br 28.6 br 28.6 br 28.6 br 15.9 br 19.1 br 19.1 br 22.2 br 22.2 br high pressure switch, fan driver overload protector, overcurrent relay, inverter overload protector, fusible plugs Notes: Nominal cooling capacities are based on: indoor temperature: 27 CDB, 19 CWB outdoor temperature: 35 CDB equivalent refrigerant piping: 7.5m level difference: 0m Nominal heating capacities are based on: indoor temperature: 20 CDB outdoor temperature: 7 CDB/6 CWB equivalent refrigerant piping: 7.5m level difference: 0m Sound power level is an absolute value that a sound source generates. Sound pressure level is a relative value, depending on the distance and acoustic environment. Sound values are measured in a semi-anechoic room. REYQ-M7W1B 8 10 12 14 16 18 20 Modules REYQ8M REYQ10M REYQ12M REYQ14M REYQ16M Equivalent horsepower HP Number of outdoor units Number of compressors Number of connectable indoor units Minimum capacity index Maximum capacity index Cooling capacity kw Heating capacity kw Power input Cooling kw Heating kw COP Cooling Heating Capacity steps Dimensions Height mm Width mm Depth mm Weight kg 1 1 1 1 2 1 1 1 8 10 12 14 16 18 20 1 1 1 1 1 2 2 2 2 2 3 3 4 4 13 16 19 20 20 20 20 100 125 150 175 200 225 250 260 325 390 455 520 585 650 22.4 28.0 33.5 40.0 44.5 50.4 56.0 25.0 31.5 37.5 45.0 50.0 56.5 63.0 6.97 9.00 10.60 14.24 15.60 16.00 18.00 6.89 9.31 10.80 12.90 14.0 16.50 19.00 3.21 3.11 3.16 2.81 2.85 3.15 3.11 3.63 3.38 3.47 3.49 3.57 3.42 3.32 29 29 29 35 35 41 41 1,600 1,600 1,600 1,600 1,600 1,600 1,600 930 930 1,240 1,240 1,240 1,860 1,860 765 765 765 765 765 765 765 245 245 295 340 340 490 490

EYQ-M7 BSVQ-MV1 100 160 250 Power supply Total capacity of connectable indoor units Maximum number of connectable indoor units Casing Dimensions Height mm Weight Width Depth Piping connections indoor unit Liquid mm Safety devices Gas V1 mm mm kg mm outdoor unit Liquid mm Suction gas Discharge gas mm mm 1~, 220-240V, 50Hz x 100 100 < x 160 160 < x 250 5 8 5 galvanised steel plate 185 185 185 310 310 310 280 280 280 9 9 10 9.5 flare 9.5 flare 9.5 flare 15.9 flare 15.9 flare 22.2 flange 9.5 flare 9.5 flare 9.5 flare 15.9 flare 15.9 flare 22.2 flange 12.7 flare 12.7 flare 19.1 flare PCB fuse 22 24 26 28 30 32 34 36 38 40 42 44 46 48 1 1 1 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 2 2 2 3 22 24 26 28 30 32 34 36 38 40 42 44 46 48 2 2 2 2 2 2 3 3 3 3 3 3 3 3 4 5 5 5 6 6 7 7 7 8 8 8 9 9 22 32 32 32 32 32 34 36 38 40 40 40 40 40 275 300 325 350 375 400 425 450 475 500 525 550 575 600 715 780 845 910 975 1,040 1,105 1,170 1,235 1,300 1,365 1,430 1,495 1,560 61.5 68.0 72.5 78.0 84.5 89.0 96.0 101.0 106.0 113 117.0 123 129.0 134 69.0 76.5 81.5 87.5 95.0 100.0 108.0 113.0 119.0 127 132 138 145.0 150.0 19.60 23.24 24.60 26.20 29.90 31.20 32.20 33.60 35.20 38.90 40.20 41.80 45.50 46.90 20.50 22.60 23.80 25.30 27.50 28.60 32.10 33.30 34.80 37.00 38.10 39.60 41.80 42.90 3.14 2.92 2.95 2.98 2.83 2.85 2.98 3.01 3.01 2.90 2.91 2.94 2.84 2.86 3.36 3.38 3.42 3.46 3.45 3.50 3.36 3.39 3.42 3.43 3.46 3.48 3.47 3.50 41 46 46 46 51 51 56 56 56 61 61 61 68 68 1,600 1,600 1,600 1,600 1,600 1,600 1,600 1,600 1,600 1,600 1,600 1,600 1,600 1,600 2,170 2,170 2,170 2,480 2,480 2,480 3,100 3,100 3,410 3,410 3,410 3,720 3,720 3,720 765 765 765 765 765 765 765 765 765 765 765 765 765 765 540 585 585 635 680 680 830 830 880 925 925 975 1,020 1,020 page 41

Technology Iron Neodymium Magnet Low pressure side N S S N N S S High pressure side N N S Rotating Stator Field Normal torque Reluctance torque Suction Scroll Discharge Reluctance DC Motor NEW 1 Reluctance brushless DC compressor The reluctance brushless DC motor provides significant increases in efficiency compared to conventional AC inverter motors, simultaneously using 2 different forms of torque (normal and reluctance torque) to produce extra power from small electric currents. High thrust mechanism By introducing high pressure oil, the reactive force from the fixed scroll is added to the internal force, thereby reducing thrust losses. This results in improved efficiency and suppressed sound level The motor comprises powerful neodymium magnets, that create the reluctance torque. These magnets are approximately 12 times stronger than ferrite magnets and make a major contribution to its energy saving characteristics. Ferrite magnet Neodymium magnet 2 Sine Wave DC inverter Optimizing the sine wave curve, results in smoother motor rotation and improved motor efficiency. 2 1 3 i-demand function Power consumption (KVV) 8:00 12:00 16:00 20:00 Time The newly introduced current sensor minimizes the difference between the actual power consumption and the predefined power consumption. page 42

WEYQ Nominal cooling capacity kw Nominal heating capacity kw Capacity range HP Power input (nominal) Cooling kw Heating kw COP Cooling Heating Max n of indoor units to be connected Minimum capacity index Maximum capacity index Power supply Y1 Dimensions Height mm Width mm Depth mm Weight kg Colour Sound pressure levels dba Sound power levels dba Fan Type Air Flow Rate (nominal) m 3 /min Refrigerant Name Charge kg Control Refrigerant Oil Type Charged Volume l Compressor Quantity Type Starting method Piping Connections Liquid mm Discharge gas mm Gas mm Safety devices HEAT PUMP HEAT PUMP HEAT RECOVERY HEAT RECOVERY VRV-WII RWEYQ10MY1 RWEYQ20MY1 RWEYQ30MY1 RWEYQ10MY1 RWEYQ20MY1 RWEYQ30MY1 26,70 53,40 80,10 26,70 53,40 80,10 31,50 63,00 94,50 31,50 63,00 94,50 10 20 30 10 20 30 6,03 12,10 18,10 6,03 12,10 18,10 6,05 12,10 18,20 6,05 12,10 18,20 4,43 4,41 4,43 4,43 4,41 4,43 5,21 5,21 5,19 5,21 5,21 5,19 16 20 32 16 20 32 125 250 375 125 250 375 325 650 975 325 650 975 3~, 50Hz, 380-415V 3~, 50Hz, 380-415V 1000 * * 1000 * * 780 * * 780 * * 550 * * 550 * * 150 150+150 150+150+150 150 150+150 150+150+150 Ivory white (5Y7,5/1) Ivory white (5Y7,5/1) 51.0 54.0 56.0 51.0 54.0 56.0 ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** R-410A R-410A 5.2 5.2+5.2 5.2+5.2+5.2 5.2 5.2+5.2 5.2+5.2+5.2 Expansion valve (electronic type) Expansion valve (electronic type) Synthetic (ether) oil Synthetic (ether) oil ** ** ** ** ** ** 1 2 3 1 2 3 Hermetically sealed scroll compressor Hermetically sealed scroll compressor Soft start Soft start 9.52 (flare) 15.9 (flare) 19.1 (flare) 9.52 (flare) 15.9 (flare) 19.1 (flare) 22.2 (brazing) 28.6 (brazing) 34.9 (brazing) 19.1 (brazing) 22.2 (brazing) 28.6 (brazing) - - - 22.2 (brazing) 28.6 (brazing) 34.9 (brazing) HPS, inverter overload protector, fusible plugs HPS, inverter overload protector, fusible plugs Notes: Nominal cooling capacities are based on: indoor temperature: 27 CDB, 19 CWB inlet water temperature: 30 C equivalent refrigerant piping: 7.5m level difference: 0m Nominal heating capacities are based on: indoor temperature: 20 CDB inlet water temperature: 20 C equivalent refrigerant piping: 7.5m level difference: 0m This unit should not be installed outdoors, but indoors eg. in a machine room, etc. Indoor operating ambient temperature: 0 ~ 40 C. Heat rejection from the outdoor unit: 0,71kW/10HP *Dimensions of 20HP and 30HP units depend on the method of stacking **Data were not available at the time of publication page 43

ACCESSORIES RXQ-M9 5 8 10 Fixing box Refnet header KHRQ22M29H KJB111A KHRQ22M29H7 Refnet joint KHRQ22M20T KHRQ22M20T KHRQ22M29T Central drain pan kit KWC26B160 KWC26B280 RXYQ-M9 5 8, 10 12, 14, 16 Cool/heat selector Fixing box Refnet header Refnet joint Central drain pan kit KRC19-26A KJB111A KHRQ22M29H KHRQ22M29H KHRQ22M29H KHRQ22M64H KHRQ22M20T KHRQ22M20T KHRQ22M20T KHRQ22M29T KHRQ22M29T KHRQ22M64T KWC26B160 KWC26B280 KWC26B450 RXYQ-M9 18, 20 22, 24, 26 28 30, 32 Cool/heat selector Fixing box Refnet header Refnet joint Outdoor unit multi connection piping kit Central drain pan kit KWC26B280 x 2 KRC19-26A KJB111A KHRQ22M29H KHRQ22M64H KHRQ22M75H KHRQ22M20T, KHRQ22M29T, KHRQ22M64T, KHRQ22M75T BHFQ22M909 KWC26B280 KWC26B450 x 2 KWC26B450 x 2 KWC26B450 RXYQ-M9 34, 36 38 40, 42 44, 46, 48 Cool/heat selector Fixing box Refnet header Refnet joint Outdoor unit multi connection piping kit Central drain pan kit KRC19-26A KJB111A KHRQ22M29H KHRQ22M64H KHRQ22M75H KHRQ22M20T7, KHRQ22M29T7, KHRQ22M64T7, KHRQ22M75T7 BHFQ22M1359 KWC26B280 x 2 KWC26B280 KWC26B280 KWC26B450 KWC26B450 x 2 KWC26B450 x 2 KWC26B450 x 3 page 44

REYQ-M7 8, 10 12, 14, 16 Refnet header Refnet joint Central drain pan kit KHRQ23M29H KHRQ23M20T, KHRQ23M29T KWC26B280 KHRQ23M29H KHRQ23M64H KHRQ23M20T, KHRQ23M29T, KHRQ23M64T KWC26B450 REYQ-M7 18, 20 22, 24, 26 28 30, 32 Refnet header Refnet joint Outdoor unit multi connection piping kit Central drain pan kit KWC26B280 x 2 KHRQ23M29H, KHRQ23M64H, KHRQ23M75H7 KHRQ23M20T, KHRQ23M29T, KHRQ23M64T, KHRQ23M75T BHFQ23M907 KWC26B280 KWC26B450 x 2 KWC26B450 x 2 KWC26B450 REYQ-M7 34, 36 38 40, 42 44, 46, 48 Refnet header Refnet joint Outdoor unit multi connection piping kit Central drain pan kit KHRQ23M29H7 (max. 8 branches), KHRQ25M72H (max. 8 branches), KHRQ23M75H7 (max. 8 branches) KHRQ23M20T, KHRQ23M29T, KHRQ23M64T, KHRQ23M75T BHFQ23M1357 KWC26B280 x 2 KWC26B280 KWC26B280 KWC26B450 KWC26B450 x 2 KWC26B450 x 2 KWC26B450 x 3 BSVQ-M 100 160 250 Cool/heat selector Fixing box KRC19-26A KJB111A RWEYQ-M 10 20 30 Cool/heat selector Fixing box REFNET header REFNET joint Outdoor unit multi connection piping kit Water piping strainer Heat recovery Heat pump Heat recovery Heat pump Heat recovery Heat pump KRC19-26A KJB111A KHRQ23M29H KHRQ23M29H, KHRQ23M64H, KHRQ23M75H KHRQ22M29H KHRQ22M29H, KHRQ22M64H, KHRQ22M75H KHRQ23M20T, KHRQ23M29T KHRQ23M20T, KHRQ23M29T, KHRQ23M64T, KHRQ23M75T KHRQ22M20T, KHRQ22M29T KHRQ22M20T, KHRQ22M29T, KHRQ22M64T, KHRQ22M75T - BHFP26MA56 BHFP26MA84 - BHFP22MA56 BHFP22MA84 BWU26A15 (1.47MPa) ; BWU26A20 (1.96MPa) page 45

P Product Features I N D O O R U N I T S

SSurvey Indoor Units 4-way blow ceiling mounted cassette (600mm x 600mm) 20-25-32-40-50 FXZQ 4-way blow ceiling mounted cassette 20-25-32-40-50-63-80-100-125 FXFQ 2-way blow ceiling mounted cassette 20-25-32-40-50-63-80-125 FXCQ Ceiling mounted corner cassette 25-32-40-63 FXKQ Concealed ceiling unit (small) 20-25 FXDQ Slim concealed ceiling unit 20-25-32-40-50-63 FXDQ-N Concealed ceiling unit 20-25-32-40-50-63-80-100-125 FXSQ Concealed ceiling unit (large) 40-50-63-80-100-125-200-250 FXMQ Wall mounted unit 20-25-32-40-50-63 FXAQ 4-way blow ceiling suspended unit 71-100-125 FXUQ Ceiling suspended unit 32-63-100 FXHQ Floor standing unit 20-25-32-40-50-63 FXLQ Concealed floor standing unit 20-25-32-40-50-63 FXNQ p. 48 p. 50 p. 52 p. 54 p. 56 p. 58 p. 60 p. 62 p. 64 p. 66 p. 68 p. 70 p. 70 page 47

4-WAY BLOW CEILING MOUNTED CASSETTE (600mm x 600mm) Z F X Z Q Stylish & compact New and extremely compact casing (575mm in depth) enables unit to fit flush into ceilings and match standard architectural modules, without cutting ceiling tiles Modern style decoration panel in super white (RAL9010) Whisper quiet operation with sound pressure levels as low as 25dBA Excellent low draught characteristics Auto swing: Vertical auto swing moves the discharge flaps up and down to distribute air effectively throughout the room. Since the flaps can move to a 0 degree position, virtually no draught can be experienced Ceiling void is 295 mm 0 60 2-way 3 2 4 1 3 2 4 1 3 2 4 1 3 2 4 1 4-way 3 2 4 1 3 2 4 1 5 different air flow patterns: Any one of 5 air flow patterns can be freely selected between zero and 60 degrees and will then be maintained during the operational cycle of the air conditioner. Air can be discharged in any of 4 directions. Possibility to shut one or 2 flaps for easy installation in corners 3-way Since the switch box is located within the unit, it is easy to access from below for maintenance without removing ceiling tiles The unit is provided with a standard 500mm lift drain pump 500mm BRC1D527 BRC7E531W/530W Super silent, stylish unit page 48

FXZQ - M7V1B Cooling capacity Heating capacity FXZQ Power input Cooling W Power supply Heating Dimensions Unit HxWxD mm kw kw W VE Decoration panel HxWxD mm Weight Unit kg Casing Colour Decoration panel Decoration panel Sound pressure level High db(a) Sound power level Low kg db(a) db(a) Aif flow rate High m 3 /h Air filter Temperature control Low m 3 /h Piping connections Liquid flare mm Sound absorbind thermal insulation Safety devices Gas flare mm Drain mm 20 25 32 40 50 2.2 2.8 3.6 4.5 5.6 2.5 3.2 4,0 5,0 6.3 73 73 76 89 115 64 64 68 80 107 1~, 50Hz, 220-240V 286 x 575 x 575 55 x 700 x 700 18 2.7 galvanised steel plate white (RAL 9010) 30 30 32 36 41 25 25 26 28 33 47 47 49 53 58 540 540 570 660 840 420 420 420 480 600 resin net with mold resistant microprocessor thermostat for cooling and heating 6.4 12.7 VP20, external diameter 26, internal diameter 20 foamed polystyrene / foamed polyethylene PC board fuse, fan motor thermal protector Notes: Nominal cooling capacities are based on: indoor temperature: 27 CDB, 19 CWB outdoor temperature: 35 CDB equivalent piping length: 7.5m (horizontal) Nominal heating capacities are based on: indoor temperature: 20 CDB outdoor temperature: 7 CDB, 6 CWB equivalent piping length: 7.5m (horizontal) Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat ACCESSORIES FXZQ - M7V1B Wired remote control Infrared remote control Decoration panel Sealing member of air discharge outlet Panel spacer Replacement long life filter Fresh air intake kit Cooling only Heat pump Direct installation type 20 25 32 40 50 BRC1D527 BRC7E531W BRC7E530W BYFQ60B7W1 KDBHQ44B60 KDBQ44B60 KAFQ441B60 KDDQ44X60 page 49

4-WAY BLOW CEILING MOUNTED F F X F Q Elegant & compact Sound pressure levels down to 28dBA leave even the most sensitive occupant undisturbed Slimmer unit requires only 240mm of ceiling space (298mm for model 80 and above) Air flow distribution to suit ceiling heights up to 4.2m for model 80 and above Drain-up pump with increased lift of 750mm fitted as standard CASSETTE 750 mm Air can be discharged in any of four directions. Possibility to shut one or two flaps for easy installation in corners or to use 1 or 2 branches 4-way discharge 3-way discharge 2-way discharge Single branch - 8 patterns Branched 2 branches - 3 patterns Branched Closed The unit can be installed in corners... indicates the piping connection direction Closed Piping location Piping location Choice of 3 auto-swing positions for maximum comfort: standard, draught prevention, ceiling soiling prevention Simple installation Easy to fit decoration panel Suction grille can be rotated by 90 Easy height adjustment via adjuster slot Easy maintenance Easy to clean suction grille and filter Extended cleaning cycle of the heat exchanger: once every 3 years BRC1D527 BRC7C512W/513W Fits flush into each ceiling page 50

FXFQ - M7V1B FXFQ Nominal cooling capacity kw Nominal heating capacity kw Power input Cooling W Heating W Power supply Dimensions Unit HxWxD mm Decoration panel HxWxD mm Weight Unit kg Decoration panel kg Casing Colour Decoration panel Sound pressure level High db(a) Low db(a) Sound power level db(a) Air flow rate High m 3 /h Low m 3 /h Air filter Temperature control Piping connections Liquid Flare mm Gas Flare mm Drain mm Sound absorbing thermal insulation Safety devices 20 25 32 40 50 63 80 100 125 2.2 2.8 3.6 4.5 5.6 7.1 9.0 11.2 14.0 2.5 3.2 4.0 5.0 6.3 8.0 10.0 12.5 16.0 90 97 106 118 173 184 230 75 82 90 101 159 169 215 1~, 50Hz, 230V 230x840x840 288x840x840 40x950x950 40x950x950 24 28 5 5 galvanised steel plate white (10Y9/0.5) 31 31 31 32 33 34 38 40 45 28 28 28 28 28 29 32 33 36 48 48 48 49 50 51 54 56 61 780 780 780 840 960 1,080 1,680 1,680 1,860 600 600 600 600 660 840 1,200 1,260 1,440 resin net with mold resistant microprocessor thermostat for cooling and heating Ø 6.4 Ø 9.5 Ø 12.7 Ø 15.9 VP25, external diameter 32, internal diameter 25 foamed polystyrene PC board fuse, fan motor thermal protector, drain pump fuse Notes: Nominal cooling capacities are based on: indoor temperature: 27 CDB, 19 CWB outdoor temperature: 35 CDB equivalent refrigerant piping: 8m, level difference : 0m Nominal heating capacities are based on: indoor temperature: 20 CDB outdoor temperature: 7 CDB, 6 CWB equivalent refrigerant piping: 8m, level difference : 0m Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat The sound pressure is measured in an anechoic room at 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment The sound power level is an absolute value indicating of the power which a sound source generates ACCESSORIES FXFQ - M7V1B 20 25 32 40 50 63 80 100 125 Wired remote control Infrared remote control Cooling only Heat pump Decoration panel High efficiency filter 65% *1 Colorimetric method High efficiency filter 90% *1 Colorimetric method Replacement high eff. filter 65% Colorimetric method Replacement high eff. filter 90% Colorimetric method Filter chamber for above Replacement long life filter Non woven type Replacement ultra long life filter Fresh air intake kit Chamber type without T-shape and fan with T-shape and fan with T-shape, without fan Direct installation type Air discharge outlet sealing member Panel spacer Branch duct chamber Chamber connection kit KAFJ556K80 KAFJ557K80 KAFJ552K80 KAFJ553K80 KDJ55B80 BRC1D527 BRC7C513W BRC7C512W BYC125K7W1B KDDFJ55K160 KAFJ55K160 KAFJ551K160H KDDJ55B160 KDDJ55B160F KDDJ55B160K KDDJ55X160 KDBHJ55K160 KDBP55H160W KKSJ55K160 KAFJ556K160 KAFJ557K160 KAFJ552K160 KAFJ553K160 KDJ55B160 page 51

2-WAY BLOW C F X C Q Stylish & compact Slim unit can be installed in a ceiling void of only 355mm minimum ceiling height is 35 cm CEILING MOUNTED CASSETTE Depth of all units is 600mm : easy installation in false ceilings Whisper quiet operation: down to 28dBA Long life filter is provided as standard Drain-up pump with 600mm lift fitted as standard 600mm Leaves maximum floor and wall space for furniture and decorations Auto-swing mechanism ensures even room air and temperature distribution and prevents ceiling soiling. Less maintenance Maintenance operations can be performed by removing the front panel Easy to clean flat suction grille Detachable swing flaps BRC1D527 BRC7C62/67 Easy installation in narrow ceiling voids page 52

FXCQ - M7V1B Nominal cooling capacity Nominal heating capacity FXCQ Power input Cooling W Power supply Heating Dimensions Unit HxWxD mm kw kw Decoration panel HxWxD mm Weight Unit kg Casing Colour Decoration panel Decoration panel Sound pressure level High db(a) Sound power level Low W kg db(a) db(a) Air flow rate High m 3 /h Air filter Temperature control Low m 3 /h Piping connections Liquid Flare mm Sound absorbing thermal insulation Safety devices Gas Flare mm Drain mm 20 25 32 40 50 63 80 125 2.2 2.8 3.6 4.5 5.6 7.1 9.0 14.0 2.5 3.2 4.0 5.0 6.3 8.0 10.0 16.0 77 92 130 161 209 256 44 59 97 126 176 223 1~, 50Hz, 230V 305x780x600 305x995x600 305x1,180x600 305x1,670x600 53x1,030x680 53x1,245x680 53x1,430x680 53x1,920x680 26 31 32 35 47 48 8 8.5 9.5 12 galvanised steel plate white (10Y9/0.5) 33 35 35.5 38 40 45 28 29 30.5 33 35 39 45 50 50 52 54 60 420 540 720 990 1,560 1,980 300 390 540 780 1,260 1,500 resin net with mold resistant microprocessor thermostat for cooling and heating Ø 6.4 Ø 9.5 Ø 12.7 Ø 15.9 VP25, external diameter 32, internal diameter 25 felt / urethane foam PC board fuse, fan motor thermal protector, drain pump fuse Notes: Nominal cooling capacities are based on: indoor temperature: 27 CDB, 19 CWB outdoor temperature: 35 CDB equivalent refrigerant piping: 8m level difference: 0m Nominal heating capacities are based on: indoor temperature: 20 CDB outdoor temperature: 7 CDB, 6 CWB equivalent refrigerant piping: 8m level difference: 0m Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat ACCESSORIES FXCQ - M7V1B 20 25 32 40 50 63 80 125 Wired remote control Infrared remote control Decoration panel High efficiency filter 65% *1 High efficiency filter 90% *1 Filter chamber for bottom suction Replacement long life filter Cooling only Heat pump BRC1D527 BRC7C67 BRC7C62 BYBC32GJW1 BYBC50GJW1 BYBC63GJW1 BYBC125GJW1 KAFJ532G36 KAFJ532G56 KAFJ532G80 KAFJ532G160 KAFJ533G36 KAFJ533G56 KAFJ533G80 KAFJ533G160 KDDFJ53G36 KDDFJ53G56 KDDFJ53G80 KDDFJ53G160 KAFJ531G36 KAFJ531G56 KAFJ531G80 KAFJ531G160 Note: *1. Filter chamber is required when installing a high efficiency filter page 53

CEILING K F X K Q Choice of 3 auto-swing positions: 1 Standard 2 Draught prevention 3 Ceiling soiling prevention MOUNTED CORNER CASSETTE Note: Standard setting when shipped. Auto-swing mechanism ensures even room air and temperature distribution Optimum air flow conditions are created by either downward air discharge or frontal air discharge (via optional grille) or a combination of both Downward discharge Frontal discharge Combination Closed by the decoration panel Leaves maximum floor and wall space for furniture, decoration and fittings The corner cassette is specifically designed for use in rooms with shallow ceiling voids (only 220mm ceiling space required, 195mm with panel spacer, available as accessory) Drain-up pump with 500mm lift fitted as standard Min. 195 mm 20 mm Panel spacer 500 mm BRC1D527 BRC4C63/61 Slim design for flexible installation page 54

FXKQ - MVE FXKQ Cooling capacity kw Heating capacity kw Power input Cooling W Heating W Power supply VE Dimensions Unit HxWxD mm Decoration panel HxWxD mm Weight Unit kg Decoration panel kg Material Unit Colour Decoration panel Sound pressure level - 220V High db(a) Low db(a) Sound power level db(a) Air flow rate High m 3 /h Low m 3 /h Air filter Temperature control Piping connections Liquid Flare mm Gas Flare mm Drain mm Sound absorbing thermal insulation Safety devices 25 32 40 63 2.8 3.6 4.5 7.1 3.2 4.0 5.0 8.0 66 76 105 46 56 85 1~, 50Hz, 220-240V 215x1,110x710 215x1,310x710 70x1,240x800 70x1,440x800 31 34 8.5 9.5 galvanised steel plate white 38 40 42 33 34 37 * * * 660 780 1,080 540 600 900 resin net with mold resistant microprocessor thermostat for cooling and heating Ø 6.4 Ø 9.5 Ø 12.7 Ø 15.9 VP25 (external diameter 32, internal diameter 25) foamed polyethylene PC board fuse, fan motor thermal fuse, drain pump thermal fuse PC board fuse, fan motor thermal protector, drain pump thermal fuse Notes: Nominal cooling capacities are based on: indoor temperature: 27 CDB, 19 CWB outdoor temperature: 35 CDB equivalent refrigerant piping: 7.5m (horizontal) Nominal heating capacities are based on: indoor temperature: 20 CDB outdoor temperature: 7 CDB, 6 CWB equivalent refrigerant piping: 7.5m (horizontal) Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat *Data were not available at the time of publication ACCESSORIES FXKQ - MVE 25 32 40 63 Wired remote control Infrared remote control Decoration panel Panel spacer Replacement long life filter Air discharge grille Air discharge blind panel Flexible duct (with shutter) Cooling only Heat pump BYK45FJW1 KPBJ52F56W KAFJ521F56 K-HV7AW KDBJ52F56W KFDJ52F56 BRC1D527 BRC4C63 BRC4C61 BYK71FJW1 KPBJ52F80W KAFJ521F80 K-HV9AW KDBJ52F80W KFDJ52F80 page 55

CONCEALED D F X D Q Designed for hotel use: very compact dimensions (230mm high x 652mm wide) CEILING UNIT (SMALL) Can easily be mounted in a ceiling void Since only the suction and discharge grilles are visible, the system will blend in any interior décor The air suction direction can be altered from rear to bottom suction Standard suction air filter Extremely quiet in operation, both indoors and outdoors For easy mounting, the drain pan connection can be located to the left or right of the unit BRC1D527 BRC4C62/64 BRC2A51 BRC3A61 Blends beautifully with hotel rooms page 56

FXDQ - M7V1B FXDQ Nominal cooling capacity kw Nominal heating capacity kw Power input Cooling W Heating W Power supply Dimensions HxWxD mm Weight kg Casing Sound pressure level High db(a) Low db(a) Sound power level db(a) Air flow rate High m 3 /h Low m 3 /h Air filter Temperature control Piping connections Liquid Flare mm Gas Flare mm Drain mm Safety devices 20 25 2.2 2.8 2.5 3.2 50 50 1~, 50Hz, 230V 230x502x652 17 galvanised steel plate 37 32 50 402 444 312 348 resin net with mold resistant microprocessor thermostat for cooling and heating Ø6.4 Ø12.7 VP25, external diameter 27.2, internal diameter 21.6 PC board fuse Notes : Nominal cooling capacities are based on: indoor temperature: 27 CDB, 19 CWB outdoor temperature: 35 CDB equivalent refrigerant piping: 8m level difference : 0m Nominal heating capacities are based on: indoor air temperature: 20 CDB outdoor temperature: 7 CDB, 6 CWB equivalent refrigerant piping: 8m level difference : 0m Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. ACCESSORIES FXDQ - M7V1B Wired remote control Infrared remote control Wiring adapter (hour meter) *1 Cooling only Heat pump 20 25 BRC1D527, BRC2A51, BRC3A61 BRC4C64 BRC4C62 EKRP1B2 Note: *1. Fixing box: KRP1A90 page 57

SLIM D FXDQ-N Slim design for flexible installation CONCEALED CEILING UNIT Compact dimensions, can easily be mounted in a ceiling void of only 240mm Air filter Suction Chamber [Duct connection] 200mm Quiet operation: down to 29 dba sound pressure level Blends unobtrusively with any interior décor Can be installed in both new and existing buildings Leaves maximum floor and wall space for furniture, decorations and fittings Medium external static pressure facilitates unit use with flexible ducts of varying lengths BRC1D527 BRC4C62/64 Drain-up pump with 750mm lift fitted as standard Ceiling BRC2A51 BRC3A61 Easy installation in narrow ceiling voids page 58

FXDQ-NVE Cooling capacity Heating capacity FXDQ-N Power input Cooling W Power supply Heating Dimensions HxWxD mm Weight Casing Sound pressure level High db(a) Sound power level Low kw kw W VE kg db(a) db(a) Air flow rate High m 3 /min Air filter Temperature control Low Piping connections Liquid mm Sound absorbing thermal insulation Safety devices Gas Drain ACCESSORIES m 3 /min mm mm 20 25 32 40 50 63 2.2 2.8 3.6 4.5 5.6 7.1 2.5 3.2 4.0 5.0 6.3 8.0 150 150 150 160 165 181 137 137 137 147 152 168 Notes: Nominal cooling capacities are based on: Indoor temperature: 27 CDB, 19 CWB Nominal heating capacities are based on: Outdoor temperature: 35 CDB Equivalent piping length: 7.5m (horizontal) Indoor temperature: 20 CDB Outdoor temperature: 7 CDB, 6 CWB Equivalent piping length: 7.5m (horizontal) Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat * Data were not available at time of publication The sound pressure values are mentioned for a unit installed with rear suction 1~, 50Hz, 220-240V 200x900x620 200x1,100x620 26 26 26 27 28 31 galvanised steel plate 33 33 33 34 35 36 29 29 29 30 31 32 * * * * * * 9.5 9.5 10.5 10.5 12.5 16.5 7.5 7.5 8.5 8.5 10.0 13.0 removable, washable, mildew proof microprocessor thermostat for cooling and heating 6.4 6.4 6.4 6.4 6.4 9.5 12.7 12.7 12.7 12.7 12.7 15.9 VP (external diameter 26, internal diameter 20) foamed polyethylene PC board fuse, fan motor thermal protector FXDQ-NVE Infrared remote control Wired remote control cooling heating 20 25 32 40 50 63 BRC4C64 BRC4C62 BRC1D527, BRC2A51, BRC3A61 page 59

CONCEALED S F X S Q High external static pressure facilitates unit use with flexible ducts of varying lengths CEILING Low sound pressure level - 28dBA. The quiet operation of this model is ideal for exclusive stores and offices UNIT Blends unobtrusively with any interior décor When using suction panel, unit requires only 350mm of ceiling space Min. 350mm Drain-up pump with lift up to 625mm fitted as standard 625mm The air suction direction can be altered from rear to bottom suction The switch box can be reached from the side or from the bottom side of the unit for easy servicing Long life filter fitted as standard BRC1D527 BRC4C62/64 BRC2A51 BRC3A61 High flexibility for a wide variety of applications page 60

FXSQ - M7V1B Nominal cooling capacity Nominal heating capacity FXSQ Power input Cooling W Power supply Heating Dimensions Unit HxWxD mm kw kw Decoration panel HxWxD mm Weight Unit kg Casing Colour Decoration panel Decoration panel Sound pressure level High db(a) Sound power level Low W kg db(a) db(a) Air flow rate High m 3 /h Air filter Temperature control Low m 3 /h Piping connections Liquid Flare mm Sound absorbing thermal insulation Safety devices Gas Flare mm Drain mm 20 25 32 40 50 63 80 100 125 2.2 2.8 3.6 4.5 5.6 7.1 9.0 11.2 14.0 2.5 3.2 4.0 5.0 6.3 8.0 10.0 12.5 16.0 110 114 127 143 189 234 242 321 90 94 107 123 169 214 222 301 1~, 50Hz, 230V 300x550x800 300x700x800 300x1,000x800 300x1,400x800 55x650x500 55x800x500 55x1,100x500 55x1,500x500 30 30 31 41 51 52 3 3.5 3.5 4.5 6.5 6.5 galvanised steel plate white 10Y9/0.5 32 33 33 35 35 37 38 40 28 28 29 31 30 31 33 35 50 51 56 58 56 55 56 65 540 570 690 900 1,260 1,620 1,680 2,280 390 420 540 660 930 1,200 1,230 1,680 resin net with mold resistant microprocessor thermostat for cooling and heating Ø 6.4 Ø 9.5 Ø 12.7 Ø 15.9 VP25, external diameter 32, internal diameter 25 foamed polyurethane PC board fuse, fan motor thermal protector, drain pump fuse ACCESSORIES FXSQ - M7V1B Notes: Nominal cooling capacities are based on: indoor temperature: 27 CDB, 19 CWB outdoor temperature: 35 CDB equivalent refrigerant piping: 8m level difference: Om Nominal heating capacities are based on: indoor temperature: 20 CDB outdoor temperature: 7 CDB, 6 CWB equivalent refrigerant piping: 8m level difference: Om Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat The sound pressure values are mentioned for a unit installed with rear suction 20 25 32 40 50 63 80 100 125 Wired remote control Infrared remote control Decoration panel Service access panel High efficiency filter 65% *2 High efficiency filter 90% *2 Filter chamber for bottom suction Filter chamber rear suction Air suction canvas Screening door/blind board Air discharge adapter for round duct Cooling only Heat pump BRC1D527, BRC2A51, BRC3A61 BRC4C64 BRC4C62 BYBS32DJW1 BYBS45DJW1 BYBS71DJW1 BYBS125DJW1 KTBJ25K36W KTBJ25K56W KTBJ25K80W KTBJ25K160W KAFJ252L36 KAFJ252L56 KAFJ252L80 KAFJ252L160 KAFJ253L36 KAFJ253L56 KAFJ253L80 KAFJ253L160 KAJ25L36D KAJ25L56D KAJ25L80D KAJ25L160D KAJ25L36B KAJ25L56B KAJ25L80B KAJ25L160B KSA-25K36 KSA-25K56 KSA-25K80 KSA-25K160 KBBJ25K36 KBBJ25K56 KBBJ25K80 KBBJ25K160 KDAJ25K36 KDAJ25K56 KDAJ25K71 KDAJ25K140 Notes: *1. A wiring adapter (KRP1B61) per indoor unit is required if installing an electric heater. *2. If installing a high efficiency filter in the ceiling mounted built-in unit, an assembly chamber for either bottom or rear suction is required. *3. An electric heater cannot be used for VRV system cooling only. page 61

CONCEALED M F X M Q Leaves maximum floor and wall space for furniture decoration and fittings CEILING UNIT (LARGE) Complete range of models (5 31.5 kw) More than 150 Pa external static pressure allows extensive ductwork runs and flexible application: ideal for use in large areas External static pressure can be easily adjusted using a change-over switch inside the electrical box to meet the resistance in the duct system Drain-up height: 294 mm for class 40 to 125 375 mm for class 200, 250 Built-in drain pump (accessory): housing the drain pump inside the unit has reduced the required installation space BUILT-IN DRAIN PUMP Min. 590 mm Min. 470 mm Indoor unit 120 Drain pump kit Indoor unit BRC1D527 BRC4C62/64 BRC2A51 BRC3A61 High static pressure allows flexible duct design page 62

FXMQ - MVE FXMQ Nominal cooling capacity kw Nominal heating capacity kw Power input Cooling W Heating W Power supply Dimensions HxWxD mm Weight kg Casing Sound pressure level - 220V High db(a) Low db(a) Sound power level db(a) Air flow rate High m 3 /h Low m 3 /h Air filter Temperature control Piping connections Liquid Flare mm Gas mm Drain mm Sound absorbing thermal insulation Safety devices 40 50 63 80 100 125 200 250 4.5 5.6 7.1 9.0 11.2 14.0 22.4 28.0 5.0 6.3 8.0 10.0 12.5 16.0 25.0 31.5 211 284 411 619 1,294 1,465 211 284 411 619 1,294 1,465 1~, 50Hz, 220-240V 390x720x690 390x1,110x690 470x1,380x1,100 44 45 63 65 137 galvanised steel plate 39 42 43 45 48 35 38 39 42 45 * * * * * 840 1,170 1,740 2,160 3,480 4,320 690 960 1,380 1,740 3,000 3,720 cf. note 4 microprocessor thermostat for cooling and heating Ø 6.4 Ø 9.5 Ø 9.5 Ø 12.7(flare) Ø 15.9(flare) Ø19.1(brazing) Ø22.2(brazing) VP25, external diameter 32, internal diameter 25 PS1B glass fiber PC board fuse, fan motor thermal protector Notes: Nominal cooling capacities are based on: indoor temperature: 27 CDB, 19 CWB outdoor temperature: 35 CDB equivalent refrigerant piping: 7.5m (horizontal) Nominal heating capacities are based on: indoor temperature: 20 CDB outdoor temperature: 7 CDB, 6 CWB equivalent refrigerant piping: 7.5m (horizontal) Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat The air filter is not a standard accessory, but please mount it in the duct system at the suction side. Select its colorimetric method (gravity method) 50% or more. *Data were not available at the time of publication ACCESSORIES FXMQ - MVE 40 50 63 80 100 125 200 250 Wired remote control Infrared remote control Drain pump kit High efficiency filter 65% High efficiency filter 90% Filter chamber Replacement long life filter Cooling only Heat pump BRC1D527, BRC2A51, BRC3A61 BRC4C64 BRC4C62 KDU30L125VE KDU30L250VE KAFJ302L71 KAFJ302L140 KAFJ372L280 KAFJ303L71 KAFJ303L140 KAFJ373L280 KDDJ30L71 KDDJ30L140 KDJ3705L280 KAFJ301L71 KAFJ301L140 KAFJ371L280 page 63

WALL MOUNTED UNIT A F X A Q Compact and stylish design blends unobtrusively in any interior décor Dramatic weight reduction of 48% compared to the previous series Auto-swing mechanism ensures efficient air distribution via louvers that close automatically when the unit is switched off Comfortable air flow: the wide air discharge outlet distributes a comfortable air flow throughout the entire room Both horizontal flaps and front panel can easily be removed and washed 5 different discharge angles can be programmed via the remote control 10 25 40 55 70 Discharge angle automatically returns to its previous position on restart (initial setting 10 degrees for cooling and 70 degrees for heating) 10 Cooling 70 Heating All maintenance operations can be carried out from the front of the unit Drain pipe can be installed either to the left or right side of the unit Drain-pump kit is available as optional accessory, which lifts the drain 1,000mm from the bottom of the unit Height of drain-up 1,000mm Drain-up kit Indoor unit Drain-up kit BRC1D527 BRC7E618/619 Quiet operation with auto-swing comfort page 64

FXAQ-MVE Nominal cooling capacity Nominal heating capacity FXAQ Power input Cooling W Power supply Heating Dimensions HxWxD mm Weight Colour Sound pressure level High db(a) Sound power level Low kw kw W kg db(a) db(a) Air flow rate High m 3 /h Air filter Temperature control Low m 3 /h Piping connections Liquid Flare mm Sound absorbing thermal insulation Safety devices Gas Flare mm Drain mm 20 25 32 40 50 63 2.2 2.8 3.6 4.5 5.6 7.1 2.5 3.2 4.0 5.0 6.3 8.0 16 22 27 20 27 50 24 27 32 20 32 60 1~, 50Hz, 220-240V 290x795x230 290x1,050x230 11 14 white (3.OY8.5/0.5) 35 36 37 39 42 46 29 29 29 34 36 39 * * * * * * 450 480 540 720 900 1,140 270 300 330 540 720 840 resin net washable microprocessor thermostat for cooling and heating Ø6.4 Ø9.5 Ø12.7 Ø15.9 VP13 (external diameter 18, internal diameter 14) foamed polystyrene / foamed polyethylene PC board fuse Notes: Nominal cooling capacities are based on: indoor temperature: 27 CDB, 19 CWB outdoor temperature: 35 CDB equivalent refrigerant piping: 5m (horizontal) Nominal heating capacities are based on: indoor temperature: 20 CDB outdoor temperature: 7 CDB, 6 CWB equivalent refrigerant piping: 5m (horizontal) Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat *Data were not available at the time of publication ACCESSORIES FXAQ-MVE 20 25 32 40 50 63 Wired remote control Infrared remote control Drain pump kit Cooling only Heat pump BRC1D527 BRC7E619 BRC7E618 K-KDU572CVE page 65

4-WAY BLOW U F X U Q Group control with other VRV indoor units Cool/heat selection available To prevent cold draught at hot start, defrost and oil return in heating CEILING SUSPENDED UNIT 5m maximum distance between indoor unit and junction box Air can be discharged in any of four directions Possibility to shut one or two flaps for easy installation in corners Auto-swing mechanism ensures even room air and temperature distribution Air flow distribution for ceiling heights up to 3.5m Air can be discharged at 5 different angles between 0 and 60 degrees. BRC1D527 BRC7C529W/528W Extremely quiet in operation both indoors and outdoors The air filter, drain pan and heat exchanger fin are mildew proof and anti-bacterial treated Drain-up pump with increased lift of 500mm BEVQ-MVE Ideal for installation in new or existing buildings page 66

FXUQ-MV1 Nominal cooling capacity Nominal heating capacity ACCESSORIES FXUQ-MV1 FXUQ Power input Cooling W Power supply Heating Dimensions HxWxD mm Weight Colour Sound pressure level High db(a) Low kw kw W V1 kg db(a) Sound power level High db(a) Low db(a) Air flow rate High m 3 /h Air filter Low m 3 /h Piping connections Liquid Flare mm Heat insulation Safety devices Combination with junction box Gas Flare mm Drain Flare mm Notes: 71 100 125 8.0 11.2 14.0 9.0 12.5 14.0 180 289 289 160 269 269 1~, 50Hz, 230V 165x895x895 230x895x895 230x895x895 25 31 31 white 40 43 44 35 38 39 56 59 60 51 54 55 1,140 1,740 1,920 840 1,260 1,380 resin net with mold resistant 9.5 9.5 9.5 15.9 15.9 15.9 external diameter 26, internal diameter 20 heat resistant foamed polyethylene, regular foamed polyethylene fan motor thermal protector BEVQ71MVE BEVQ100MVE BEVQ125MVE Nominal cooling capacities are based on: indoor temperature: 27 CDB, 19 CWB outdoor temperature: 35 CDB, 24 CWB Nominal heating capacities are based on: indoor temperature: 20 CDB, 15 CWB outdoor temperature: 7 CDB, 6 CWB Capacities are net including a deduction for cooling (an addition for heating) for indoor fan motor heat 71 100 125 Wired remote control Infrared remote control Sealing member of air discharge outlet Air discharge decoration panel Vertical flap kit Replacement long life filter L-type connection piping kit Cooling only Heat pump KDBHJ49F80 KDBTJ49F80 KDGJ49F80 KHFP49M63 BRC1D527 BRC7C529W BRC7C528W KAFJ495F140 KDBHJ49F140 KDBTJ49F140 KDGJ49F140 KHFP49M140 JUNCTION BOX FOR CONNECTION TO VRV BEVQ-MVE Dimensions HxWxD mm Weight kg Casing Power supply VE 71 100 125 100x350x225 3.0 3.0 3.5 galvanised steel plate 1~, 50Hz, 220-240V page 67

CEILING SUSPENDED H F X H Q Quiet in operation: down to 31 dba sound pressure level Leaves maximum floor and wall space for furniture and decoration Can be installed in both new and existing buildings UNIT Use of W-Coanda flap enhances horizontal and vertical air circulation characteristics Sound absorption member Turbulent flow Straightening vane Silent stream fan Wider air discharge thanks to Coanda effect: up to 100 degrees Coanda effect 100 Long life filter fitted as standard Drain-up kit with 600mm lift available as accessory Drain-up kit (built inside main unit) Easy installation and maintenance BRC1D527 BRC7E63W/66 Super silent, slim unit with wider air flow page 68

FXHQ - MVE FXHQ Nominal cooling capacity kw Nominal heating capacity kw Power input Cooling W Heating W Power supply Dimensions HxWxD mm Weight kg Colour Sound pressure level High db(a) Low db(a) Sound power level db(a) Air flow rate High m 3 /h Low m 3 /h Air filter Temperature control Piping connections Liquid Flare mm Gas Flare mm Drain mm Sound absorbing thermal insulation Safety devices 32 63 100 3.6 7.1 11.2 4.0 8.0 12.5 111 115 135 111 115 135 1~, 50Hz, 220-240V 195x960x680 195x1,160x680 195x1,400x680 24 28 33 white (10Y9/0.5) 36 39 45 31 34 37 * * * 720 1,050 1,500 600 840 1,170 resin net with mold resistant microprocessor thermostat for cooling and heating Ø 6.4 Ø 9.5 Ø 9.5 Ø 12.7 Ø 15.9 Ø 15.9 VP20 (external diameter 26, internal diameter 20) glass wool PC board fuse, fan motor thermal protector Notes: Nominal cooling capacities are based on: indoor temperature: 27 CDB, 19 CWB outdoor temperature: 35 CDB equivalent refrigerant piping: 7.5m (horizontal) Nominal heating capacities are based on: indoor temperature: 20 CDB outdoor temperature: 7 CDB, 6 CWB equivalent refrigerant piping: 7.5m (horizontal) Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat *Data were not available at the time of publication ACCESSORIES FXHQ - MVE 32 63 100 Wired remote control Infrared remote control Drain pump kit Replacement long life filter L-type piping kit Cooling only Heat pump Resin net For upward direction BRC1D527 BRC7E66 BRC7E63W KDU50M60VE KDU50M125VE KDU50M125VE KAFJ501D56 KAFJ501D80 KAFJ501D112 KHFP5M35 KHFP5M63 KHFP5M63 page 69

(CONCEALED) FLOOR STANDING UNIT L N FXLQ/FXNQ Ideal for installation beneath a window The floor standing unit is a mere 222mm deep and 600mm high and requires very little installation space Running the pipes from connections at the back, enables the unit to be wall mounted which in turn allows cleaning beneath the unit where dust tends to accumulate Wall mounted On site connection during installation is easier Floor standing Long life filter fitted as standard All models are available with remote control The connecting port faces downward, eliminating the need to attach auxiliary piping Connecting port Refrigerant piping BRC1D527 BRC4C64/62 BRC2A51 BRC3A61 The ideal unit for perimeter air conditioning page 70

FXLQ/FXNQ-MVE FXLQ/FXNQ Nominal cooling capacity kw Nominal heating capacity kw Power input Cooling W Heating W Power supply Dimensions FXLQ HxWxD mm FXNQ HxWxD mm Weight FXLQ kg FXNQ kg Colour FXLQ Casing FXNQ Sound pressure level - 220V High db(a) Low db(a) Sound power level db(a) Air flow rate High m 3 /h Low m 3 /h Air filter Temperature control Piping connections Liquid Flare mm Gas Flare mm Drain mm Sound absorbing thermal insulation Safety devices ACCESSORIES FXLQ/FXNQ-MVE Wired remote control Infrared remote control Replacement long life filter Cooling only Heat pump page 71 20 25 32 40 50 63 2.2 2.8 3.6 4.5 5.6 7.1 2.5 3.2 4.0 5.0 6.3 8.0 49 90 110 49 90 110 1~, 50Hz, 220-240V 600x1,000x222 600x1,140x222 600x1,420x222 610x930x220 610x1,070x220 610x1,350x220 25 30 36 19 23 27 ivory white (5Y7.5/1) galvanised steel plate 35 35 38 39 40 32 32 33 34 35 * * * * * 420 480 660 840 960 360 360 510 660 720 resin net with mold resistant microprocessor thermostat for cooling and heating Ø6.4 Ø9.5 Ø12.7 Ø15.9 Ø21 external diameter (vinyl chloride) glass fiber / urethane foam PC board fuse, fan motor thermal protector Notes: Nominal cooling capacities are based on: indoor temperature: 27 CDB, 19 CWB outdoor temperature: 35 CDB equivalent refrigerant piping: 7.5m (horizontal) Nominal heating capacities are based on: indoor temperature: 20 CDB outdoor temperature: 7 CDB, 6 CWB equivalent refrigerant piping: 7.5m (horizontal) Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat *Data were not available at the time of publication 20 25 32 40 50 63 BRC1D527, BRC2A51, BRC3A61 BRC4C64 BRC4C62 KAFJ361K28 KAFJ361K45 KAFJ361K71

P Product Features CONTROL SYSTEMS

Individual Control Systems Centralised Control Systems SSurvey Control Systems Simplified remote control BRC2A51 Simplified built-in remote control for hotel applications BRC3A61 Infrared remote control BRC4C*/BRC7C* Wired remote control BRC1D527 Centralised remote control DCS302C51 Unified ON / OFF control DCS301B51 Schedule timer p. 74 p. 74 p. 74 p. 75 p. 76 p. 76 Daikin Network Solutions DST301B51 p. 76 DTA113B51 p. 77 page 73 DCS601C51 DAM602A51/52/53 DMS504B51 DMS502A51 p. 78 p. 80 p. 81 p. 81

IIndividual Control Systems Simplified remote control simple, compact and easy to operate unit suitable for use in hotel bedrooms. Operation buttons : ON/OFF Operating mode selection Fan speed control Temperature setting BRC2A51 Display : Cool/heat changeover control Heat Recovery Ventilation (HRV) in operation Set temperature Operating mode Centralised control indication Fan speed Defrost/hot start Malfunction adjustment Operating mode selection Fan speed control Filter sign reset Inspection test / operation Simplified built-in remote control for hotel applications compact,user friendly unit ideal for use in hotel bedrooms. BRC3A61 Operation buttons : ON/OFF Fan speed control Temperature setting Display : Heat Recovery Ventilation (HRV) in operation Set temperature Operating mode Centralised control indication Fan speed Defrost/hot start Malfunction Infrared remote control Operation buttons: ON/OFF Timer mode start / stop Timer mode on/off Programme time Temperature setting BRC4C*/BRC7C* Air flow direction (FXHQ, FXFQ, FXCQ and FXAQ models only) Operating mode Fan speed control Filter sign reset Inspection / test indication Display: Operating mode Battery change Set temperature Air flow direction (FXHQ, FXFQ, FXCQ and FXAQ models only) Programmed time Inspection/test operation Fan speed page 74

BRC1D527 BRC1D527 Wired remote control Limit operation (min./max.): room temperature is controlled within adjustable upper and lower limits. Limit operation can be activated manually or by schedule timer Real time clock: indicates real time and day Schedule timer: - It is possible to programme a weekly schedule timer - It is possible to programme the remote control for each day of the week. Five day actions can be set as follows: - set point: unit is switched ON and normal operation is maintained - OFF: unit is switched OFF - limits: unit is switched ON and min./max. control (cf.limit operation for more details) Home leave (frost protection): during absence, the indoor temperature can be maintained at a certain level. This function can also switch the unit ON/OFF Different levels of disabled buttons can be selected as follows: level 1: all buttons are accessible level 2: all buttons are disabled except for: - ON/OFF - set temperature up/down - fan speed - cooling/heating mode - enable/disable schedule timer - air flow direction adjustment button level 3: all buttons are disabled except for: - ON/OFF - set temperature up/down - fan speed user friendly HRV function, thanks to the introduction of a button for ventilation mode and fan speed constantly monitoring of the system for malfunctions in a total of 80 components immediate display of fault location and condition reduction of maintenance time and costs. Operation buttons: ON/OFF Timer mode start/stop Timer on/off Programmed time Temperature setting Air flow direction adjustment Operating mode selection Fan speed control Filter sign reset Inspection test/operation Display: Operating mode Heat Recovery Ventilation (HRV) in operation Cool/heat changeover control Centralised control indication Group control indication Set temperature Air flow direction Programmed time Inspection/test operation Fan speed Clean air filter Defrost/hot start Malfunction page 75

CCentralised Control Systems Centralised control of the VRV system can be achieved via 3 user friendly compact controls: centralised remote control, unified on/off control and schedule timer. These controls may be used independently or in combination where 1 group = several (up to 16) indoor units in combination and 1 zone = several groups in combination. A centralised remote control is ideal for use in tenanted commercial buildings subject to random occupation, enabling indoor units to be classified in groups per tenant (zoning). The schedule timer programmes the schedule and operation conditions for each tenant and the control can easily be reset according to varying requirements. DCS302C51 Centralised remote control Providing individual control of 64 groups (zones) of indoor units. a maximum of 64 groups (128 indoor units, max. 10 outdoor units) can be controlled a maximum of 128 groups (128 indoor units, max. 10 outdoor units) can be controlled via 2 centralised remote controls in separate locations zone control group control malfunction code display maximum wiring length of 1,000m (total: 2,000m) HRV air flow direction and air flow rate can be controlled expanded timer function DCS301B51 Unified ON/OFF control Providing simultaneous and individual control of 16 groups of indoor units a maximum of 16 groups (128 indoor units) can be controlled 2 remote controls in separate locations can be used operating status indication (normal operation, alarm) centralised control indication maximum wiring length of 1,000m (total: 2,000m) DST301B51 Schedule timer Enabling 64 groups to be programmed a maximum of 128 indoor units can be controlled 8 types of weekly schedule a maximum of 48 hours back up power supply a maximum wiring length of 1,000m (total: 2,000m) page 76

NEW DDaikin Network Solutions The ideal solution for control and management up to 2,000 indoor units DS-NET adapter PC for monitoring Modem Public phone line RS485 Malfunction Modem RS232C Application area Max. of 10 DS-NET adapters A small commercial area of less than 40 indoor units. Critical applications for centralized monitoring. System layout Allows monitoring and control of up to up to 50 stores or sites and 2,000 indoor units with just one modem and phone line. Automates daily air conditioning operation in order to free users from the hassle of air conditioning operation/management. The daily schedule setting allows automatic operation afterward. Automates alarm (report messages) for any malfunctions/errors. Immediate report of any indoor unit breakdown to the servicing company. Automatic report of breakdown/ malfunction information. Minimizes the inconvenience of not having air conditioning via rapid messages Functions Schedule setup (Daily schedule) - Start/Stop Air conditioning malfunction report - Send message to monitoring system Manual operation - Start/Stop, Set temperature, Operation mode, Fan speed Status monitoring (Start/Stop, Set temperature, Operation mode, Room temperature, Operation time, Error code) *DS-net can also be controlled via your mobile phone page 77

Allows detailed & easy monitoring and operation of VRV systems (max. 2 X 64 groups/indoor units). Public line AIRNET Onboard modem NEW Fire alarm Forced OFF contact input PCMCIA flash memory CSV output of PPD (option) result DIII-NET Pi-port Indoor units HRV Onboard Ethernet port Links to the wattmeter when using the PPD (option) function DIO unit Controls drain pump lighting etc. NEW NEW Malfunction Monitoring of room enter/exit sign Remote monitoring/control via internet, e-mail DI unit RS-232C DIII-NET Allows monitoring/control of up to 64 units (groups) of A/Cs and equipment DIII-NET PLUS adapter NEW Indoor unit HRV page 78

NEW NEW NEW NEW Languages English French German Italian Spanish System layout Up to 2 x 64 indoor units can be controlled Onboard Ethernet port (web browser + e-mail) Digital i/o contacts (option) Touch panel (full colour LCD via icon display) Management Web application & internet compatibility - Monitoring & control according to user - Remote monitoring & control of more than one building - Remote monitoring & control of more than one building via internet NEW NEW NEW NEW NEW Power Proportional Distribution: PPD (option) Easy management of electricity consumption Enhanced history function Control Individual control (set point, start/stop, fan speed) (max. 2 x 64 groups/indoor units) Schedule control (8 schedules, 17 patterns) Flexible grouping in zones Yearly schedule Fire emergency stop control Interlocking control (option) Increased HRV monitoring and control function Automatic cooling/heating change-over Heating optimization Temperature limit Password security: 3 levels (general, administration & service) Quick selection and full control Simple navigation NEW NEW Monitoring Visualisation via Graphical User Interface (GUI) Icon colour display change function Indoor units operation mode Error messages via e-mail & mobile phone (option) Indication filter replacement Multi PC Cost performance Labour saving Easy installation Compact design: limited installation space Overall energy saving Connectable to: VRV HRV Sky Air (via interface adapter) Split (via interface adapter) page 79

The ideal solution for control and management of maximum 1,024 VRV indoor units. System layout Up to 1,024 indoor units can be controlled (by 4 ipus) Ethernet TCPIP / 10 base/ T communication Integrated digital contacts on the Intelligent Processing Unit (ipu) 19 general input ports 2 digital outputs Stand alone operation of the ipu for minimum 48 hours Compatible with UPS shutdown software Operation Status Monitoring Schedule Management Tenant Management...etc HRV 4 units max. Fire alarm [ipu] Intelligent Processing unit Security Unified on/off control Centralised remote control VRV System Management Proportional power consumption division Operational history management (start/stop, malfunction, operation hours) Generation of reports (graphics & tables) (daily, weekly, monthly) Peak load shedding Advanced tenant management Sliding temperature Eco mode Control Individual control (setpoint, start/stop, fan speed) (max. 1,024 indoor units) Group control (100 groups) Schedule control (128 programs) Fire emergency stop control (32 programs) Interlocking control Setpoint limitation Automatic cool-heat changeover Power failure/release control Temperature limit (automatic start) Timer extension Monitoring Visualisation via a Graphical User Interface (GUI) featuring free layout Operation mode of indoor & outdoor units Fault indication Indication filter replacement Setpoint indication Operation time monitoring Multi PC On-line help page 80

LONWORKS Networks Compatible Gateway DDaikin Network Solutions Interface for connection to LONWORKS networks Communication via LON protocol (twisted pair wire) 64 units connectable per DMS-IF Unlimited site size Quick and easy installation Fire alarm Security Elevator Pump Lighting...etc Power supply facility LON BMS LON (FTT-10A) ~ Unified on/off control ~ Centralised remote control HRV VRV System Integrated control system connecting VRV system with BMS system. Interface for BMS system Communication via BACnet protocol (connection via Ethernet) 256 units connectable per BACnet gateway Unlimited site size Easy and fast installation Fire alarm Security Elevator Pump Lighting...etc Power supply facility BMS BACnet over ethernet ~ ~ Unified on/off control Centralised remote control HRV VRV System page 81

ACCESSORIES CONTROL SYSTEMS DESCRIPTION Wired remote control Infrared remote control Simplified remote control Simplified remote control for hotel use cooling only heat pump 1. INDIVIDUAL CONTROL SYSTEMS FXZQ FXFQ FXCQ FXKQ FXDQ FXDQ-N FXSQ FXMQ FXUQ FXHQ FXAQ FXLQ FXNQ BRC1D527 BRC7E531W BRC7C513W BRC7C67 BRC4C63 BRC4C64 BRC4C64 BRC4C64 BRC4C64 BRC7C529W BRC7E66 BRC7E619 BRC4C64 BRC4C64 BRC7E530W BRC7C512W BRC7C62 BRC4C61 BRC4C62 BRC4C62 BRC4C62 BRC4C62 BRC7C528W BRC7E63W BRC7E618 BRC4C62 BRC4C62 - - - - BRC2A51 BRC2A51 BRC2A51 BRC2A51 - - - BRC2A51 BRC2A51 - - - - BRC3A61 BRC3A61 BRC3A61 BRC3A61 - - - BRC3A61 BRC3A61 DESCRIPTION Centralised remote control Unified ON/OFF control Schedule timer 2. CENTRALISED CONTROL SYSTEMS FXZQ FXFQ FXCQ FXKQ FXDQ FXDQ-N FXSQ FXMQ FXUQ FXHQ FXAQ FXLQ FXNQ DCS302C51 DCS301B51 DST301B51 3. OTHERS DESCRIPTION Wiring adapter Wiring adapter for electrical appendices (1) Wiring adapter for electrical appendices (2) Remote sensor Installation box for adapter PCB Electrical box with earth terminal (3 blocks) Electrical box with earth terminal (2 blocks) Noise filter (for electromagnetic interface only) External control adapter for outdoor units (must be installed on indoor units) Option PCB for external electric heater, humidifier and/or hour meter *6 Interface adapter for Sky Air series Forced ON/OFF connector FXZQ FXFQ FXCQ FXKQ FXDQ FXDQ-N FXSQ FXMQ FXUQ FXHQ FXAQ FXLQ FXNQ KRP1B57* EKRP1B2* 5 EKRP1B2* 5 KRP1B61 KRP1B61 KRP1B56 KRP1B61 KRP1B61 - KRP1B3 - KRP1B61 KRP1B61 KRP2A52* KRP2A52* KRP2A51* KRP2A61 KRP2A51 KRP2A53 KRP2A51 KRP2A62 - KRP2A62* KRP2A61* KRP2A51 KRP2A51 KRP4A53* KRP4A53* KRP4A51* KRP4A51 KRP4A51 KRP4A54 KRP4A51 KRP4A52 KRP4A53* KRP4A52* KRP4A51* KRP4A51 KRP4A51 KRCS01-1 KRP1B101 *2 KRP1C98 KRP1B96 *3/4 - - KRP1B101 - - KRP1B97 KRP1C93 *3 KRP4A93* 3/4 - - KJB311A - KJB311A KJB212A - KJB212A KEK26-1 - KEK26-1 DTA104A62* DTA104A62* DTA104A61* DTA104A61 DTA104A61 DTA104A53 DTA104A61 DTA104A61 - DTA104A62 DTA104A61 DTA104A61 DTA104A61 - - - - - - EKRP1B2 - - - - - - - - - - - - - - DTA102A52 - - - - - - - - - - - - EKF0F0 - - - - Notes: An installation box is required for each adapter marked with * *2: Up to 2 installation boxes can be installed per indoor unit *3: Only 1 installation box can be installed per indoor unit *4: Up to 2 adapters can be fixed per installation box *5: Hour meter *6: Electric heater and humidifier are field supplied. These parts should not be installed inside the equipment. 4. DESCRIPTION REFERENCE COMMENTS DS-net adapter DTA113B51 4 units can be connected per adapter, 40 units when 10 adapters are connected Software DPC001B1-B51 Monitoring panel software page 82

5. DESCRIPTION REFERENCE COMMENTS Intelligent Touch Controller DCS601C51 2x64 units can be connected Software DCS002C51 Power Proportional Distribution (PPD) software DCS004A51 E-mail / Web software Hardware DCS601A52 DIII NET-Plus adapter Installation box KJB411A For wall mounted installation Touch-Pen 1264009 Spare part n of Touch-Pen for Intelligent Touch Controller Interface adapters KRP928A2S For connection to Split units DTA102A52 For connection to R-22 / R-407C Sky Air units DTA112B51 For connection to R-410A Sky Air units Digital input DEC101A51 Input contacts: 16 points Digital input/output DEC102A51 Input contacts: 8 points; output contacts: 4 points 6. DESCRIPTION REFERENCE COMMENTS Intelligent Processing unit DAM602A51 256 indoor units per IPU DAM602A52 128 indoor units per IPU DAM602A53 192 indoor units per IPU Software IM3.XX Up to 1,024 indoor units Interface adapters KRP928A2S For connection to Split units DTA102A52 For connection to R-407C/R-22 Sky Air units DTA112B51 For connection to R-410A Sky Air units DIII Ai DAM101A51 Outdoor temperature sensor Digital input DEC101A51 Input contacts: 16 points Digital input/output DEC102A51 Input contacts: 8 points, output contacts: 4 points 7. DESCRIPTION REFERENCE COMMENTS LONWORKS networks compatible Gateway DMS504B51 Up to 64 units can be connected per DMS-IF Interface adapters KRP928A2S For connection to Split units DTA102A52 For connection to R-407C/R-22 Sky Air units DTA112B51 For connection to R-410A Sky Air units 8. DESCRIPTION REFERENCE COMMENTS BACnet Gateway DMS502A51 64 units per Gateway DIII board DAM411A1 Extension of 3 x DIII lines (3 x 64) indoor units Digital input/output DAM412A1 For forced shutdown Interface adapters KRP928A2S For connection to Split units DTA102A52 For connection to R-407C/R-22 Sky Air units DTA112B51 For connection to R-410A Sky Air units 9. BMS: BUILDING MANAGEMENT SYSTEM DESCRIPTION REFERENCE COMMENTS Contact / analog signal Parallel interface - Basic unit Temperature measurement units Temperature setting units Unification adapter for computerised control Wiring adapter for electrical appendices (1) Wiring adapter for electrical appendices (2) External control adapter for outdoor unit DIII-net expander adapter Mounting kit DPF201A51 DPF201A52 DPF201A53 DCS302A52 KRP2A51 KRP2A52 KRP4A51-53 DTA104A51 DTA104A52 DTA109A51 KRP4A92 enables ON/OFF command, operation and display of malfunction can be used in combination with up to 4 units. enables temperature measurement output for 4 groups; 0~5VDC." enables temperature setting input for 16 groups; 0~5VDC." used for combining of air conditioning control computer and central remote controller (ON/OFF, display) simultaneously controls air conditioning control computer and up to 64 groups of indoor units. to control the group of indoor units collectively, which are connected by the transmission wiring of remote controller. cooling/heating mode change over, demand control and low noise control are available between the plural outdoor units. a maximum of 10 outdoors or 128 indoors can be connected to 1 DTA109A51 a maximum of 8 DTA109A51 can be connected to DIII-net for easy installation of the DTA109A51 page 83

Daikin Europe N.V. is approved by LRQA for its Quality Management System in accordance with the ISO9001 standard. ISO9001 pertains to quality assurance regarding design, development, manufacturing as well as to services related to the product. ISO14001 assures an effective environmental management system in order to help protect human health and the environment from the potential impact of our activities, products and services and to assist in maintaining and improving the quality of the environment. Daikin units comply with the European regulations that guarantee the safety of the product. VRV products are not within the scope of the Eurovent certification programme Specifications are subject to change without prior notice Zandvoordestraat 300 B-8400 Oostende, Belgium www.daikineurope.com Daikin products are distributed by: EPCE03-06D / 3900 / 05/05 La Movida Printed on non-chlorinated paper / Printed in Belgium