Technical Manual WATER SOFTENER. Models: SLI-CS- SLI-BBS-ECO erie water treatment TM-EN-SLI-CS_BBS-Rev

Similar documents
Technical Manual WATER SOFTENER. Models: SLI-CS- SLI-BBS-ECO erie water treatment TM-EN-SLI-CS_BBS-Rev

Technical Manual WATER SOFTENER. Models: MAX-CS erie water treatment TM-EN-MAX-CS-Rev

Technical Manual WATER SOFTENER. Models: IQ-CS erie water treatment TM-EN-IQ-CS-Rev

Technical Manual WATER SOFTENER. Models: PF-SOF1-SIM PF-SOF1-ALT PF-SOF1-PRL PF-SOF1,5-SIM PF-SOF1,5-ALT PF-SOF1,5-PRL PF-BTA

Technical Manual WATER SOFTENER. Models: PF-SOF1-SIM PF-SOF1-ALT PF-SOF1-PRL PF-SOF1,5-SIM PF-SOF1,5-ALT PF-SOF1,5-PRL PF-BTA

Technical Manual WATER SOFTENER. Models: PF-SOF1-SIM PF-SOF1-ALT PF-SOF1-PRL PF-SOF1,5-SIM PF-SOF1,5-ALT PF-SOF1,5-PRL PF-BTA

Technical Manual WATER SOFTENER

MULTI-PURPOSE WATER FILTER

WATER FILTER - ph CORRECTION

Technical Manual WATER FILTER. Models: PF-GAC1 PF-AG1 PF-GAC1,5 PF-AG1, erie water treatment TM-EN-PF-GAC_AG-Rev

541D19 SERIES. Technical Manual. A Division of Aquion Partners L.P.

Commandomatic Ezysoft WATER SOFTENER SYSTEM

Owner's Manual. WS Series. Water Softener

1850 Series TRIPLE TREAT Operation Manual

Spectrum TM. Installation, Service & Operation Manual O FLO. SoftH 2. Water Softener. Table of Contents

OWNER S MANUAL. Premium Series Two Tank 1-PLUS-1 Water Conditioner & Whole House Filters

User Manual AF-30-VT

Water Softener Installation Guide Effective for all Softeners from our Range

Autotrol Performa FA Valve

Water Softener & Single Tank Triple Treat System Installation Overview. Using 1850 Metered Valves

What to expect from your water softener

Installation and Operation Manual

WS1 Softener Installation & Start-Up Guide

WS1 Greensand Installation & Start Up Guide

6700 Valve Downflow. Automatic Water Softeners Operation Manual. Read all instructions carefully before operation. #51431 Rev.

Clean Water Made Easy. Fleck 7000 Tannin Filter Installation & Startup Guide. Questions?

Owner's Manual. Whole House Water Softener with Triton Electronic Control Valve. or call

TITAN Pro-Max High Efficiency Upflow Water Conditioner Installation and Operation Manual

TITAN VI High Efficiency Water Conditioner Installation and Operation Manual

Installation & Service Manual

Clean Water Made Easy

MP-MBA-45T-1/60T-1 / 75T-1

Record of System Specifications 2 Product Dimensions 3 Pre-Installation Checklist 4 System Installation 5-9 Installation Notice, Unit location,

INSTALLATION MANUAL ESM9+ / ESM11+ / ESM15+

6700 Valve Upflow. Automatic Water Softeners Operation Manual. Read all instructions carefully before operation. #57341 Rev.

NovoSoft 465 Series SIM Water Softener Operation Manual

Green Water Systems OWNERS MANUAL. Includes: Installation Procedures, Warranties, Service & Operation Guidelines.

RevV4 Valves & Systems Service Manual. Innovative Solutions for Your Water

Whirlpool. Model WHES40. Model WHES44. Model WHESCS. Water softener. Installation and operation manual * How to install, operate

AUTOTROL 363TC AUTOMATIC FILTER VALVE SERVICE MANUAL

OptiSoft Softeners Simple Install Steps 1-17

Metermatic Water Softener. Operation Manual

Econoflo SXT Automatic Meter Initiated Water Softener

MASTER. Water Conditioning Corp. MP-TS-10T/20T with the 255/762 Logix Control Valve With Vortech. Installation and Operation Manual

Clean Water Made Easy

6700XTR Upflow Valve. Water Softener Operation Manual. Read all instructions carefully before operation. #51548 Rev. 2/09

7800 Neutralizer Installation & Start-Up Guide

RIVERSOFT Water Softener System

7000 Meter Initiated Valve

5700-E Sediment Filter Installation & Start-Up Guide

Fully Automatic Water Softeners

ProFlo SXT Valve Downflow / Upflow

Clean Water Made Easy. CWS Time Clock Softener Installation & Start Up Guide. Questions?

6700XTR Valve Downflow

High Flow 7000 SXT Series Water Softeners

Fleck 2510 SXT Catalox Installation & Start Up Guide

5900S Softener Installation & Start-Up Guide

High Flow 7000 SXT Water Softener

Fleck 7000 Sediment Filter Installation & Start-Up Guide

SHOWER SOFTENER-CEASA 1

FLECK 5600 WATER SOFTENER INSTALLATION

AUTOTROL 363 DEMAND AUTOMATIC FILTER VALVE Service Manual

O P E R A T I N G M A N U A L

Plumbline 2000 Series Metered Softeners Owners Manual Water Softener Models

Clean Water Made Easy

EVOLIO-560 Water Softener System

Installation Instructions and Owner s Manual. CITY Series Water Softening and Filter System

Fleck 5600 Carbon Filter Installation & Start Up Guide

Fleck 5600 SXT. Installation Guide. Make a list of all of the plumbing fittings needed to install; a typical list looks like this:

Installation Instructions and Owner s Manual. XBW & XBW-ARSENIC Series. Backwashing Filter Systems

Owner s Manual. Keep with machine for reference PKC24 INSTALLATION & OPERATION REV Perlick Corporation 8300 W Good Hope Rd Milwaukee, WI 53223

CWS Plus Sediment Filter Installation & Start Up Guide

Water Softener Installation / Operation Manual

IMPORTANT SAFETY INFORMATION READ ALL...

Installation Instructions & Owner's Manual. IM & INT Series

565 TLC Softener & Tannins Reduction System

2.0 HIGH CAPACITY SIMPLEX WATER SOFTENER INSTALLATION AND OPERATIONS MANUAL

GLC/GW-100 MANUAL INSTALLATION SERVICE PARTS REV.1.01

FULLY AUTOMATIC WATER SOFTENER

Installation and Operations Manual

ProSystems, a Division of Aquion, Inc East Lunt Avenue Elk Grove Village, Illinois

Fleck 2510 Softener Installation & Start Up Guide

Engineers manual. Under counter machines

Installation and Operation Manual

PRF-RO Pentair Reverse Osmosis System Installation and Maintenance Manual SAFETY GUIDES THE BASIC REVERSE OSMOSIS SYSTEM. Tools and Materials Required

The Professional s Choice

Fully Automatic Water Softeners

HD / HDL Valves & Systems Service Manual

Water Softener. Operating Manual

Models EP100 & EP200. How to install, operate and maintain your Demand Controlled Water Softener. Do not return water softener to store

Plumbline 1000 Series Timered Softeners Owners Manual Water Softener Models

Cabinet Non-Electric Water Softener

OWNER S MANUAL. How to install, operate and maintain your. EcoWater Systems Automatic Sediment Filter. EcoWater Systems Poland

AQUARIUS 45 MARINE SERVICE MANUAL

This material is intended only for Glass Water Systems customers. Reproduction or distribution of this material is strictly prohibited and protected.

7500-S Sediment Backwash Filter Guide

This unit is superb for commercial applications where soft water is required 100% of the time.

CONTENTS. Page. Contents 1. Introduction, features and benefits 2. PART ONE Overview of the softening process 4-5

5900-BT Softener Installation & Start-Up Guide

Models NST30ED NST45ED1 NST70ED1

Transcription:

Technical Manual WATER SOFTENER Models: SLI-CS- SLI-BBS-ECO 2017 erie water treatment TM-EN-SLI-CS_BBS-Rev2017.03

TABLE OF CONTENT Table of content...page 2 Warning & Safety instructions...page 3 Operating conditions & Requirements...Page 4 Installation...Page 5 Commissioning...Page 6 Electronic control panel...page 7 Maintenance...Page 11 Hydraulic flow diagrams - Eco...Page 13 Hydraulic flow diagrams - Eco +...Page 14 Troubleshooting...Page 15 Electrical wiring diagrams...page 17 Default configuration parameter settings - SLI-CS...Page 18 Default configuration parameter settings - SLI-BBS...Page 19 Exploded view - SLI-CS - Mini, Midi system...page 20 Exploded view - SLI-CS - Maxi system...page 22 Exploded view - SLI-BBS - System...Page 24 Exploded view - Valve body assembly - Eco...Page 26 Exploded view - Valve body assembly - Eco +...Page 28 Exploded view - SLI-CS - Valve head assembly...page 30 Exploded view - SLI-BBS - Valve head & timer assembly...page 31 Technical data - SLI-CS-Eco...Page 32 Technical data - SLI-CS-Eco +...Page 33 Technical data - SLI-BBS-Eco...Page 34 Technical data - SLI-BBS-Eco +...Page 35 Page 2

WARNING & SAFETY INSTRUCTIONS Before you begin the installation of the appliance, we advise you read and carefully follow the instructions contained in this manual. It contains important information about safety, installation, use and maintenance of the product. The actual system that you have received, may differ from the pictures/illustrations/descriptions in this Technical Manual. Failure to follow the instructions could cause personal injury or damage to the appliance or property. Only when installed, commissioned and serviced correctly, the appliance will offer you many years of trouble-free operation. The appliance is intended to 'soften' the water, meaning it will remove hardness minerals; it will not necessarily remove other contaminants present in the water. The appliance will not purify polluted water or make it safe to drink! Installation of the appliance should only be undertaken by a competent person, aware of the local codes in force. All plumbing and electrical connections must be done in accordance with local codes. Before setting up the appliance, make sure to check it for any externally visible damage; do not install or use when damaged. Use a hand truck to transport the appliance. To prevent accident or injury, do not hoist the appliance over your shoulder. Do not lay the appliance on its side. Keep this Technical Manual in a safe place and ensure that new users are familiar with the content. The appliance is designed and manufactured in accordance with current safety requirements and regulations. Incorrect repairs can result in unforeseen danger for the user, for which the manufacturer cannot be held responsible. Therefore repairs should only be undertaken by a competent technician, familiar and trained for this product. In respect of the environment, the appliance should be disposed of in accordance with Waste Electrical and Electronic Equipment requirements. Refer to national/local laws and codes for correct recycling of this appliance. Page 3

OPERATING CONDITIONS & REQUIREMENTS OPERATING PRESSURE MIN-MAX: 1,4-8,3 bar / 20-120 psi this appliance is configured to perform optimally at an operating pressure of 3 bar (45 psi) ±½ bar (7 psi); in case of a lower or higher operating pressure the performance may be affected negatively! check water pressure regularly; it may fluctuate severely depending on the time of day, the day of the week or even the season of the year. take into account that night time water pressure may be considerably higher than day time water pressure. install a pressure reducer ahead of the appliance if necessary. install a pressure booster, if it is likely that water pressure may drop below the minimum. OPERATING TEMPERATURE MIN-MAX: 2-48 C / 35-120 F do not install the appliance in an environment where high ambient temperatures (e.g. unvented boiler house) or freezing temperatures can occur. the appliance cannot be exposed to outdoor elements, such as direct sunlight or atmospheric precipitation. do not install the appliance too close to a water heater; keep at least 3 m (10 ft) of piping between the outlet of the appliance and the inlet of the water heater; water heaters can sometimes transmit heat back down the cold pipe into the appliance; always install a check valve at the outlet of the appliance. ELECTRICAL CONNECTION: the appliance only works on 24 VAC; always use it in combination with the supplied transformer. make sure to plug the transformer into a power outlet, which is installed in a dry location, with the proper rating and overcurrent protection. Page 4

INSTALLATION PREPARATION BRINE CABINET (only for SLI-CS-) Picture 1&11.a To facilitate the installation, you may want to remove the salt lid and main cover from the brine cabinet. PLACEMENT BRINE CABINET (only for SLI-BBS-) This 2-tank system consists of a pressure tank with control valve and a separate brine cabinet. Place both items at the desired installation location, no more than 1 meter apart. INLET & OUTLET In case of high concentration of impurities in the inlet water, we recommend the installation of a sediment filter, ahead of the appliance. We strongly recommend the use of flexible hoses to connect the appliance to the water distribution system; use hoses with a large diameter in order to limit the pressure loss. If the appliance is not equipped with the factory bypass (optional), we strongly recommend to install a 3-valve bypass system (not included with this product!) to isolate the appliance from the water distribution system in case of repairs. It allows to turn off the water to the appliance, while maintaining (untreated) water supply to the user. WITH FACTORY BYPASS (optional) Picture 2 = mains water supply (untreated water) = inlet of appliance (untreated water) = outlet of appliance (treated water) = house/application (treated water) 1. Screw the factory bypass onto the elbow connections of the appliance ( & ); make sure to install the gasket seals. Tighten the nuts firmly by hand. 2. Screw the connection kit with nuts onto the factory bypass ( & ); make sure to install the gasket seals. Tighten the nuts firmly by hand. 3. Connect the mains water supply to the adaptor on the inlet port of the factory bypass ( ). 4. Connect the house/application to the adaptor on the outlet port of the factory bypass ( ). 5. Connect the house/application to the outlet of the 3-valve bypass system. DRAIN We recommend the use of a stand pipe with P-trap. To prevent backflow from the sewerage system into the appliance, always install and use the included drain adaptor with air gap and double hose barb, to connect the drain hoses to the sewerage system. Always use separate drain hoses for the control valve (discharge of rinse water) and the brine cabinet's overflow. Lay-out the drain hoses in such a way that pressure loss is minimized; avoid kinks and unnecessary elevations. Make sure that the sewerage system is suitable for the rinse water flow rate of the appliance. Picture 4 1. Install the drain adaptor to the sewerage system; it fits over a 32 mm pipe or inside a 40 mm pipe adaptor. Ensure a permanent and watertight connection. 2. Connect a 13 mm hose to the drain solenoid of the control valve ( ); secure it by means of a clamp. 3. Run the drain hose to the drain adaptor and connect it to one of the hose barbs; secure it by means of a clamp. This drain line operates under pressure, so it may be installed higher than the appliance. 4. Connect a 13 mm hose to the brine cabinet overflow elbow; secure it by means of a clamp. 5. Run the drain hose to the drain adaptor and connect it to the other hose barb; secure it by means of a clamp. This drain line does NOT operate under pressure, so it may NOT be installed higher than the appliance. BRINE CABINET (only for SLI-BBS-) Picture 5 1. Run the polytube from the brine cabinet to the control valve. 6. Insert the polytube into the Quick-Fit brine line connection on the control valve ( ). WITH 3-VALVE BYPASS SYSTEM (not included) Picture 3 = inlet of appliance (untreated water) = outlet of appliance (treated water) 1. Install the 3-valve bypass system. 2. Screw the connection kit with nuts onto the elbow connections of the appliance ( & ); make sure to install the gasket seals. Tighten the nuts firmly by hand. 3. Connect the 3-valve bypass system to the adaptors on the in ( ) and out ( ) elbow connections. 4. Connect the mains water supply to the inlet of the 3-valve bypass system. Page 5

COMMISSIONING ELECTRICAL Picture 6 1. Plug the transformers output lead into the socket on the appliances power cord; secure it by means of the TwistLock clamp. 2. Plug the transformer into an electrical outlet. PRESSURIZING 1. Make sure the bypass system is in 'bypass' position. 2. Make sure the electronic controller of the appliance is in service mode. 3. Open the mains water supply. 4. Open a cold treated water faucet nearby the appliance and let the water run for a few minutes until all air is purged and all foreign material that may have resulted from the installation is washed out; close the tap. 5. Gently pressurize the appliance, by putting it into service: factory bypass: 1. open the 'outlet' valve; 2. slowly open the 'inlet' valve. 3-valve bypass: 1. close the 'bypass' valve; 2. open the 'outlet' valve; 3. slowly open the 'inlet' valve. 6. After 2-3 minutes, open a cold treated water faucet nearby the appliance and let the water run for a few minutes until all air is purged from the installation and the resin bed is rinsed (it is normal for the rinse water to show some discoloration!); close the tap. 7. Check the appliance and all hydraulic connections for leaks. to reduce the residual hardness: turn the screw clockwise. 2. Measure the residual water hardness with a water hardness test kit; readjust if necessary. PERFORM REGENERATION 1. Manually initiate a regeneration, by pressing the scroll button; the display will show: Regen in 10 sec 2. Leave the appliance in this position; the countdown timer will countdown to 0 sec and start a regeneration. After the first regenerations of the appliance, some slight discoloration of the treated water might occur. This is totally harmless and will disappear rapidly! BRINE CABINET 1. Add water conditioner salt to the brine cabinet. ELECTRONIC CONTROL PANEL 1. Program the electronic controller. ADJUSTMENT RESIDUAL HARDNESS WITH FACTORY BYPASS (optional) In practice the residual hardness is influenced by the inlet pressure, flow rate and hardness of the incoming untreated water. When adjusting the residual hardness, make sure these conditions are similar to the actual operating conditions. Picture 7 1. Adjust the residual hardness of the water that leaves the softener, by means of the adjusting screw, incorporated in the outlet valve of the factory bypass: to raise the residual hardness: turn the screw counter clockwise. Page 6

ELECTRONIC CONTROL PANEL Picture 8 symbol button function SCROLL to advance to the next parameter UP to increase the value of the parameter DOWN to decrease the value of the parameter POWER-UP After power-up the display will show the 5-digit Part Number of the electronic board and the installed software version. POWER FAILURE In the event of a power failure, the program will remain stored in the NOVRAM during an undefined period, while an incorporated SuperCap will maintain the correct time of day during a period of several hours; consequently, in case of prolonged power failure, the time of day might not be maintained; if this happens, the time of day will be reset to 8:00 when the power supply is re-established, while the indication will flash, indicating that the time of day needs to be set. When the power failure occurs during the execution of an automatic regeneration, the appliance will immediately return to the service mode; when the power supply is reestablished, the appliance will resume the regeneration. TIMER FAILURE In the event of a timer failure, the display will show the message: Service Required The buzzer, if enabled (see Basic Settings), will beep continuously. If powering off/on the appliance doesn t solve this problem, professional service is required. MAINTENANCE REMINDER Only available if the maintenance reminder function has been activated and programmed by your supplier! Once the maintenance interval is reached, the following will happen: 1. the display will intermittently show the message: 8:01 1000L Maintenance Now 2. the buzzer, if enabled (see Basic Settings), will beep 3 times every hour. While the appliance will continue to operate normally, it is recommended to have preventive maintenance performed by a professional. To reset the maintenance reminder, simply access the configuration parameters programming mode. SERVICE MODE In service mode the display shows: on 1 st line: the time of day and the remaining capacity; on 2 nd line: the total volume of water used since commissioning. 8:01 1000L TotVol: 1234567L REGENERATION MODE In regeneration mode the display shows the actual regeneration cycle and, where relevant, the total remaining regeneration time and remaining cycle time: BRINE FILL REGEN PENDING Rgn:XXX CycY:ZZZ The appliance can be reset to service mode at any time by pressing the scroll button, as such manually advancing it through the regeneration cycles. CHECKING THE FLOW METER In case of water usage, the remaining capacity counter in the service display will count back per unit, i.e. per litre. This way the correct functioning of the water meter can be verified. MANUAL REGENERATION It is possible to manually initiate an immediate regeneration or a delayed regeneration (at the preprogrammed time of regeneration). 1. Press the scroll button; the display will show: Regen in 10 sec If the control panel is left in this position, the countdown timer will countdown to 0 sec and start an immediate regeneration. To cancel this mode, press the scroll button before the countdown timer has reached 0 sec; the display will show: Regen @ 2:00 Page 7

ELECTRONIC CONTROL PANEL If the control panel is left in this position, a delayed regeneration will be started at the indicated preprogrammed time of regeneration. To cancel this mode, press the scroll button repeatedly; the control panel will return to the service mode. PROGRAMMING INSTRUCTIONS - BASIC SETTINGS Before entering the programming mode, make sure that the appliance is in service mode. In case no button is pressed in a period of 5 min, the control panel will automatically return to the service mode; any changes made will NOT be saved! 1. Press the scroll button and hold it for 2 sec until the display shows: Language:English Press the up or down button to set the language. 2. Press the scroll button again; the display will show: Set time: 8:01 Press the up or down button to set the time of day. 3. Press the scroll button again; the display will show: HardUnit: f Press the up or down button to set the unit of measure for water hardness. Make sure it is identical to the unit of measure of the water hardness test kit or water analysis report that is used to determine the hardness of the incoming untreated water! 4. Press the scroll button again; the display will show: Set hardn: XX f Press the up or down button to set the hardness of the incoming untreated water. 5. Press the scroll button again; the display will show: Buzzer: ON Press the up or down button to enable or disable the buzzer. 6. Press the scroll button again; the display will show: Exit Press the up or down button to save the settings into the NOVRAM and exit the programming mode. PROGRAMMING INSTRUCTIONS - CONFIGURATION PARAMETERS All configuration parameters on this appliance have been pre-programmed in the factory, to offer optimal performance in a wide range of applications and situations. See table at the end of this manual for default configuration parameter settings. Before entering the programming mode, make sure that the appliance is in service mode. In case no button is pressed in a period of 5 min, the control panel will automatically return to the service mode; any changes made will NOT be saved! 1. Press the scroll button and hold it for 6 sec until the display shows: System Check 2. Within 10 sec, press the up button; the display will show: Units:Metric Press the up or down button to set the units of measure (Metric or US). 3. Press the scroll button again; the display will show: MaintInt: OFF Press the up or down button to activate the maintenance reminder function by setting the maintenance interval, or deactivate the maintenance reminder function. 4. Press the scroll button again; the display will show: ExCap:5.1 f M3/L Press the up or down button to set the exchange capacity per litre of resin. 5. Press the scroll button again; the display will show: Resin:XXX liters Page 8

ELECTRONIC CONTROL PANEL Press the up or down button to set the volume of resin. 6. Press the scroll button again; the display will show: Override: 7 days Press the up or down button to set the number of days between regenerations. 7. Press the scroll button again; the display will show: Cycle 1: XXX sec Press the up or down button to set the length of the regeneration cycle. Press the scroll button again to advance to the next regeneration cycle. Eco Eco + Refill Cycle 1 Cycle 1 Brine preparation Cycle 2 Cycle 2 Backwash / Cycle 3 Brine draw/slow rinse Cycle 3 Cycle 4 Fast rinse / Cycle 5 8. Press the scroll button again; the display will show: Regen:Dlyd/Immd Press the up or down button to set the reserve capacity: Variable: the reserve capacity is calculated automatically, based on the registered daily water usage. Fxd: press the scroll button again and press the up or down button to set the reserve capacity to a fixed amount. 11. Press the scroll button again; the display will show: AUX: Regen Press the up or down button to set the function of auxilliary contact 1 and auxiliary contact 2: Regen: aux. contact is powered during entire regeneration (does not include refill and brine preparation cycles!). Chlor.Cell: aux. contact is powered at start of brine draw/slow rinse cycle. Press the scroll button again and press the up or down button to set the duration of activation of the chlorination cell. Maintenance: aux. contact is powered when Maintenance Reminder is triggered. Error: aux. contact is powered when timer failure occurs. 12. Press the scroll button again; the display will show: Exit Press the up or down button to set the regeneration mode: Dlyd/Immd: when the remaining capacity equals the reserve capacity, a delayed regeneration is started at the programmed time of regeneration; however when the remaining capacity equals 0 before the programmed time of regeneration is reached, an immediate regeneration is started. Immediate: when the remaining capacity equals 0, an immediate regeneration is started. Delayed: when the remaining capacity equals the reserve capacity, a delayed regeneration is started. Press the up or down button to save the settings into the NOVRAM and exit the programming mode. 9. Press the scroll button again; the display will show (only when the regeneration mode was set to 'Delayed' or 'Dlyd/Immd'): Regen @ 2:00 Press the up or down button to set the time of regeneration. 10. Press the scroll button again; the display will show (only when the regeneration mode was set to 'Dlyd' or 'Dlyd/Immd'): Rsrv Variable Page 9

ELECTRONIC CONTROL PANEL DIAGNOSTICS MODE In the Diagnostics mode several operating parameters can be consulted; particularly during a service intervention, these parameters can be helpful to identify the cause of a problem or malfunction. Before entering the Diagnostics mode, make sure that the appliance is in service mode. In case no button is pressed in a period of 5 min, the control panel will automatically return to the service mode! Accessing the Diagnostics mode 1. Press the scroll button and hold it for 6 sec until the display shows: System Check 2. Within 10 sec, press the down button; the display will show: Regen XXdays ago You are now in the Diagnostics mode. Press the scroll button to advance to the next diagnostics parameter. Available diagnostics parameters Regen X days ago: number of days since last regeneration. In Srvc: total number of days in service. # of Regens: number of regenerations since installation. TotVol: total volume of treated water since installation. LastSet: number of days since last change of configuration parameter or hardness of incoming untreated water. InstFlow: instantaneous flow rate through appliance. AvgVol: calculated average daily water usage. LastRgn@: consumed capacity at last regeneration. Capacity: calculated capacity between regenerations. MaintCnt: current status of maintenance reminder counter (counting up). MP Resets: number of resets of microprocessor (for factory purpose only). Memory Reset: number of corrupt memory start-ups (for factory purpose only). CapToUse: remaining capacity. Fill: length of refill cycle of last regeneration. Reserve: calculated reserve capacity. EZ3P5f EZ3PB r14: software version. Exiting the Diagnostics mode 1. Press the scroll button repeatedly until the display shows: Exit Press the up or down button to exit the Diagnostics mode. Page 10

MAINTENANCE RECOMMENDATION Notwithstanding the reliability of the appliance, we strongly recommend to have it serviced and maintained on a regular basis by a competent and duly trained technician. He will be able to determine the appropriate maintenance interval for the appliance, depending on your specific application and the local operating conditions. The advantages of performing regular maintenance are: regular check of the local operating conditions (water quality, pressure, etc); regular control and adjustment of the settings of the appliance, to guarantee it operates at maximum efficiency; minimize the risk of unexpected break-down. Contact your dealer or installer for more information, or visit our website. ROUTINE CHECKS Regularly the user should perform a basic check to verify if the appliance is functioning correctly, on the basis of the following control points: 1. Check settings of electronic control panel. 2. Measure water hardness before/after appliance. 3. Check drain line from control valve; there shouldn t be any water flow (unless appliance is in regeneration). 4. Check drain line from brine cabinet overflow; there shouldn t be any water flow. 5. Check appliance and surrounding area; there shouldn t be any water leakages. BYPASSING THE APPLIANCE Occasionally it may be necessary to put the appliance hydraulically in bypass, i.e. to isolate it from the water distribution system; f.e.: in case of an urgent technical problem; when it is not necessary to supply treated water to the house/application (refill swimming pool, irrigation,...). WITH FACTORY BYPASS (optional) Picture 9.a SERVICE POSITION = inlet valve to appliance is OPEN = outlet valve from appliance is OPEN Picture 9.b BYPASS POSITION = inlet valve to appliance is CLOSED = outlet valve from appliance is CLOSED Picture 9.c MAINTENANCE POSITION = inlet valve to appliance is OPEN = outlet valve from appliance is CLOSED WITH 3-VALVE BYPASS SYSTEM (not included) Picture 10.a SERVICE POSITION = bypass valve is CLOSED = inlet valve to appliance is OPEN = outlet valve from appliance is OPEN Picture 10.b BYPASS POSITION = bypass valve is OPEN = inlet valve to appliance is CLOSED = outlet valve from appliance is CLOSED Picture 10.c MAINTENANCE POSITION = bypass valve is OPEN = inlet valve to appliance is OPEN = outlet valve from appliance is CLOSED WATER CONDITIONER SALT Picture 11 The appliance needs 'brine' for its periodic regenerations. This brine solution is made from water, that is automatically dosed in the brine cabinet by the control valve, and water conditioner salt. The user should make sure that the brine cabinet is always kept full of water conditioner salt. Therefore he should periodically check the salt level inside the brine cabinet and refill it if necessary. The salt lid can be removed completely to facilitate refilling. Ideally the level of water conditioner salt inside the brine cabinet is kept between 1/3 and 2/3. A lower level of water conditioner salt can cause insufficient brine saturation, resulting in a loss of softening capacity. A higher level of water conditioner salt can cause salt bridging (hard crust or salt bridges in the brine cabinet). When you suspect salt bridging: carefully pound on the outside of the brine cabinet to break loose the salt bridges; using a broom (or like blunt tool) carefully push the salt to break it apart; pour warm water over the top of the salt to dissolve it. APPEARANCE To retain the appearance of the appliance, simply wipe it with a damp cloth or clean it with a mild soap solution; never use abrasive cleaners, ammonia or solvents. RESIN CLEANER Other contaminants (f.e. iron) present in the feed water can cause the resin bed to foul up, resulting in a loss of softening capacity. An approved resin cleaner can be used periodically to thoroughly clean the resin bed. Page 11

MAINTENANCE SANITIZING THE APPLIANCE This appliance is manufactured from premium quality material and assembled in safe conditions to assure it is clean and sanitary. If installed and serviced correctly, this appliance will not infect or contaminate your water supply. However, as in any 'device' plumbed-in in your water distribution system, a proliferation of bacteria is possible, especially in case of 'stagnant water'. Therefore this appliance is equipped with a 'days override' feature, that will automatically rinse the resin bed periodically, even in case of low or absence of water usage. If the power supply to the appliance is disconnected for a longer period of time, we recommend, when the power supply is re-established, to manually initiate a complete regeneration. Page 12

HYDRAULIC FLOW DIAGRAMS - ECO SERVICE REFILL BRINE PREP. BRINE DRAW SLOW RINSE SERVICE REFILL BRINE PREPARATION BRINE DRAW / SLOW RINSE Page 13

HYDRAULIC FLOW DIAGRAMS - ECO + SERVICE REFILL BRINE PREP. BACKWASH BRINE DRAW SLOW RINSE FAST RINSE SERVICE REFILL BRINE PREPARATION BACKWASH BRINE DRAW / SLOW RINSE FAST RINSE Page 14

TROUBLESHOOTING PROBLEM CAUSE SOLUTION Hard (untreated) water Open or defective bypass Close or replace bypass to service Appliance in regeneration Wait until regeneration finishes or manually advance regeneration to end No salt in brine cabinet Add salt and initiate regeneration manually Salt bridging Break salt bridge(s) and initiate regeneration manually Change in raw water hardness Measure the hardness of the incoming untreated water and adjust programming accordingly Appliance fails to regenerate Refer to problem Appliance fails to regenerate Control valve fails to draw brine Refer to problem Valve fails to draw brine Decreasing exchange capacity of resin Clean or replace resin bed Loss of resin Refer to problem Loss of resin Leak at riser tube Verify that riser tube is seated correctly and is not cracked Residual hardness in Bypass not completely closed Close bypass treated water Appliance is overrunning its softening capacity Measure the hardness of the incoming untreated water and adjust programming accordingly Verify operation of flow meter Appliance fails to Faulty electrical supply Verify electrical service (fuse, transformer,...) regenerate Defective flow meter Verify operation of flow meter Defective PCB Replace PCB Defective drain solenoid Replace drain solenoid Control valve does not switch to regeneration position Check operating pressure; must be higher than 1,4 bar Appliance uses too Excessive water in brine cabinet Refer to problem Excessive water in brine cabinet much salt System regenerates too frequently Measure the hardness of the incoming untreated water and adjust programming accordingly Excessive water in Improper brine draw Refer to problem Improper brine draw brine cabinet Improper setting of refill cycle Verify setting of refill cycle Missing refill flow control Verify that refill flow control is installed and properly sized Leak from control valve to brine cabinet Clean or replace plunger and solenoid diaphragm of refill solenoid Check seal between brine draw check ball and brine draw restrictor Salt taste in treated Improper setting of brine draw/slow rinse cycle Verify setting of brine draw/slow rinse cycle water Excessive water in brine tank Refer to problem Excessive water in brine tank Improper brine draw Refer to problem Improper brine draw Loss of water pressure Mineral or iron build-up in resin tank Clean resin bed and control valve; increase regeneration frequency Plugged lower and/or upper distributor Verify that distributors are free of debris Crushed lower and/or upper distributor Replace distributor(s) Drain line from control valve flows Appliance in regeneration Wait until regeneration finishes or manually advance regeneration to end continuously Drain solenoid stuck in open position Clean drain solenoid Defective PCB Replace PCB Drain line from brine Excessive water in brine cabinet Refer to problem Excessive water in brine cabinet cabinet overflow flows Leak between control valve and pressure tank Verify seal between control valve and pressure tank continuously Control valve fails to Improper setting of refill cycle Verify setting of refill cycle refill brine tank Plugged refill flow control Clean refill flow control Refill solenoid not opening Verify operation of refill solenoid Loss of resin Lower and/or upper distributor damaged Replace distributor(s) Leak between riser tube and upper distributor Verify that riser tube is seated correctly and is not cracked Page 15

TROUBLESHOOTING PROBLEM CAUSE SOLUTION Improper brine draw Low operating pressure Check operating pressure; must be higher than 1,4 bar Plugged injector and/or brine draw restrictor Clean injector and/or brine draw restrictor Plugged injector filter Clean injector filter Restricted drain line Verify drain line for kinks or restrictions Restricted brine line Verify brine line for kinks or restrictions Leak in brine line Verify brine line and connections for air leakage No water in brine tank Refer to problem Control valve fails to refill brine tank Eco + only: backwash solenoid remains open Verify operation of backwash solenoid Page 16

ELECTRICAL WIRING DIAGRAMS ECO = flow meter = power lead = auxilliary contact (24 VAC, max. 500mA) = refill solenoid (white) = drain solenoid = key pad ECO + = flow meter = power lead = auxilliary contacts (24 VAC, max. 500mA) = refill solenoid (white) = backwash solenoid (black) = drain solenoid = key pad Page 17

DEFAULT CONFIGURATION PARAMETER SETTINGS - SLI-CS Model SLI-CS-Eco- Resin 11 14 17 24 30 Units Metric Metric Metric Metric Metric MaintInt (mths) OFF OFF OFF OFF OFF Exchange capacity per liter resin ( f M 3 /L) (1) (2) 4,5 4,5 5,1 5,1 5,1 Resin (liters) 11 14 17 24 30 Override (days) 7 7 7 7 7 Cycle 1: REFILL (sec) (2) 242 308 374 528 660 Cycle 2: BRINE PREPARATION (min) 15 15 15 15 15 Cycle 3: BRINE DRAW/SLOW RINSE (min) 57 59 72 109 133 Regen Dlyd/Immd Dlyd/Immd Dlyd/Immd Dlyd/Immd Dlyd/Immd Regen @ 2:00 2:00 2:00 2:00 2:00 Rsrv Variable Variable Variable Variable Variable Auxilliary contact 1 Regen Regen Regen Regen Regen Auxilliary contact 2 Regen Regen Regen Regen Regen (1) When the Hardness Unit is changed in the Basic Settings, the Exchange capacity per liter resin is automatically converted to the new Hardness Unit. (2) When the Exchange capacity per liter resin is changed, the refill cycle time needs to be adjusted accordingly. Model SLI-CS-Eco + - Resin 11 14 17 24 Units Metric Metric Metric Metric MaintInt (mths) OFF OFF OFF OFF Exchange capacity per liter resin ( f M 3 /L) (1) (2) 4,5 4,5 5,1 5,1 Resin (liters) 11 14 17 24 Override (days) 7 7 7 7 Cycle 1: REFILL (sec) (2) 242 308 374 528 Cycle 2: BRINE PREPARATION (min) 15 15 15 15 Cycle 3: BACKWASH (min) 3 3 3 3 Cycle 4: BRINE DRAW/SLOW RINSE (min) 57 70 102 128 Cycle 5: FAST RINSE (min) 2 2 2 2 Regen Dlyd/Immd Dlyd/Immd Dlyd/Immd Dlyd/Immd Regen @ 2:00 2:00 2:00 2:00 Rsrv Variable Variable Variable Variable Auxilliary contact 1 Regen Regen Regen Regen Auxilliary contact 2 Regen Regen Regen Regen (1) When the Hardness Unit is changed in the Basic Settings, the Exchange capacity per liter resin is automatically converted to the new Hardness Unit. (2) When the Exchange capacity per liter resin is changed, the refill cycle time needs to be adjusted accordingly. Page 18

Model DEFAULT CONFIGURATION PARAMETER SETTINGS - SLI-BBS SLI-BBS-Eco- Resin 11 14 30 Units Metric Metric Metric MaintInt (mths) OFF OFF OFF Exchange capacity per liter resin ( f M 3 /L) (1) (2) 4,5 4,5 5,1 Resin (liters) 11 14 30 Override (days) 7 7 7 Cycle 1: REFILL (sec) (2) 242 308 660 Cycle 2: BRINE PREPARATION (min) 15 15 15 Cycle 3: BRINE DRAW/SLOW RINSE (min) 57 59 133 Regen Dlyd/Immd Dlyd/Immd Dlyd/Immd Regen @ 2:00 2:00 2:00 Rsrv Variable Variable Variable Auxilliary contact 1 Regen Regen Regen Auxilliary contact 2 Regen Regen Regen (1) When the Hardness Unit is changed in the Basic Settings, the Exchange capacity per liter resin is automatically converted to the new Hardness Unit. (2) When the Exchange capacity per liter resin is changed, the refill cycle time needs to be adjusted accordingly. Model SLI-BBS-Eco + - Resin 11 24 Units Metric Metric MaintInt (mths) OFF OFF Exchange capacity per liter resin ( f M 3 /L) (1) (2) 4,5 5,1 Resin (liters) 11 24 Override (days) 7 7 Cycle 1: REFILL (sec) (2) 242 528 Cycle 2: BRINE PREPARATION (min) 15 15 Cycle 3: BACKWASH (min) 3 3 Cycle 4: BRINE DRAW/SLOW RINSE (min) 57 128 Cycle 5: FAST RINSE (min) 2 2 Regen Dlyd/Immd Dlyd/Immd Regen @ 2:00 2:00 Rsrv Variable Variable Auxilliary contact 1 Regen Regen Auxilliary contact 2 Regen Regen (1) When the Hardness Unit is changed in the Basic Settings, the Exchange capacity per liter resin is automatically converted to the new Hardness Unit. (2) When the Exchange capacity per liter resin is changed, the refill cycle time needs to be adjusted accordingly. Page 19

EXPLODED VIEW - SLI-CS - MINI, MIDI SYSTEM Page 20

EXPLODED VIEW - SLI-CS - MINI, MIDI SYSTEM Item PN Description Remark (*) 1 PT/1016/CP Pressure tank 10x16 Eco 11L, Eco 14L, Eco + 11L PT/0922/CP Pressure tank 9x22 Eco 17L, Eco + 14L 2 E8000 Softening resin 3 38528 Riser tube assembly with deflector to be cut to length 4 287/166 Top distributor 5 568/303/6 Connection kit ¾ male 6 541NCX9B/J80 Valve body assembly Eco 541NCX4B/J8J Valve body assembly Eco + 11L 541NCX4B/J8G Valve body assembly Eco + 14L 7 38529 Cover assembly 8 H1015/2 Brine line polytube to be ordered per meter 9 38519 Brine line filter 10 H1016/2 Brine well cap, top 11 DM/A6EU6 Quick-fit elbow 3/8 12 38530 Brine valve assembly 464 to be cut to length 13 BW3.5/047 Brine well, 47 cm Eco 11L, Eco 14L, Eco + 11L BW3.5/060 Brine well, 60 cm Eco 17L, Eco + 14L 14 38536 Screw rivet, brine well 15 H1016/4 Brine well cap, bottom 16 72263 Twist lock clamp, power cord 17 28/298/11 Transformer 230/24V - 50 Hz, 24VA, EuroT plug 18 70971 Power cord 19 72760 Flow meter cable 20 72761 Drain solenoid cable 21 72686 Refill solenoid cable (white) 22 72685 Backwash solenoid cable (black) Eco + 23 38531 PCB housing assy 24 39058 PCB frame 25 74280 Printed Circuit Board Eco 74279 Printed Circuit Board Eco + 26 15/102 Screw, PCB 27 39059 Back plate 28 19098 Retainer, back plate 29 38631 Cable tie 30 38628 Cabinet body, mini Eco 11L, Eco 14L, Eco + 11L 39070 Cabinet body, midi Eco 17L, Eco + 14L 31 38532 Overflow assembly 32 39004 Dome label erie water treatment 33 38522 Drain hose to be ordered per meter 34 38521 Clamp, drain hose (4x) 35 74163 Air gap with double hose barb (*) Recommended Spare Part Page 21

EXPLODED VIEW - SLI-CS - MAXI SYSTEM Page 22

EXPLODED VIEW - SLI-CS - MAXI SYSTEM Item PN Description Remark (*) 1 PT/0932/CP Pressure tank 9x32 Eco 24L, Eco + 17L PT/1032/CP Pressure tank 10x32 Eco 30L, Eco + 24L 2 E8000 Softening resin 3 38528 Riser tube assembly with deflector to be cut to length 4 287/166 Top distributor 5 568/303/6 Connection kit ¾ male 6 541NCX9B/J80 Valve body assembly Eco 541NCX4B/J8G Valve body assembly Eco + 17L 541NCX4B/J8J Valve body assembly Eco + 24L 7 38529 Cover assembly 8 H1015/2 Brine line polytube to be ordered per meter 9 38519 Brine line filter 10 H1016/2 Brine well cap, top 11 DM/A6EU6 Quick-fit elbow 3/8 12 38530 Brine valve assembly 464 to be cut to length 13 BW3.5/088 Brine well 14 38536 Screw rivet, brine well 15 H1016/4 Brine well cap, bottom 16 28/298/11 Transformer 230/24V - 50 Hz, 24VA, EuroT plug 17 72263 Twist lock clamp, power cord 18 70971 Power cord 19 72760 Flow meter cable 20 72761 Drain solenoid cable 21 72686 Refill solenoid cable (white) 22 72685 Backwash solenoid cable (black) Eco + 23 38531 PCB housing assy 24 39058 PCB frame 25 74280 Printed Circuit Board Eco 74279 Printed Circuit Board Eco + 26 15/102 Screw, PCB 27 39059 Back plate 28 19098 Retainer, back plate 29 38631 Cable tie 30 38690 Cabinet body, maxi 31 38532 Overflow assembly 32 39004 Dome label erie water treatment 33 38522 Drain hose to be ordered per meter 34 38521 Clamp, drain hose (4x) 35 74163 Air gap with double hose barb (*) Recommended Spare Part Page 23

EXPLODED VIEW - SLI-BBS - SYSTEM Page 24

EXPLODED VIEW - SLI-BBS - SYSTEM Item PN Description Remark (*) 1 PT/1016/BA Pressure tank 10x16 Eco 11L, Eco 14L, Eco + 11L PT/1032/BA Pressure tank 10x32 Eco 30L, Eco + 24L 2 E8000 Softening resin 3 39004 Dome label erie water treatment 4 39077 Label Slimline 5 J/1016(B) Tank jacket, mini Eco 11L, Eco 14L, Eco + 11L J/1032(B) Tank jacket, maxi Eco 30L, Eco + 24L 6 38528 Riser tube assembly with deflector to be cut to length 7 287/166 Top distributor 8 J/10 Tank jacket cover 10 9 568/232 Nut, connection kit (2x) 10 74129 Adaptor ¾ BSP male plastic (2x) 11 71110 Gasket, connection kit (4x) 12 72639 Bypass with mixing valve optional 13 541N89/J80/SLI Valve body & timer assembly Eco 11L, Eco 14L, Eco 30L 541N84/J8J/SLI Valve body & timer assembly Eco + 14L, Eco + 24L 14 28/298/11 Transformer 230/24V - 50 Hz, 24VA, EuroT plug 15 Brine cabinet cover included in item 26 16 H1015/2 Brine line polytube to be ordered per meter 17 74179 Brine line filter 18 H1016/2 Brine well cap, top 19 DM/A6EU6 Quick-fit elbow 3/8 20 38530 Brine valve assembly 464 to be cut to length 21 BW3.5/0375 Brine well Eco 11L, Eco 14L, Eco + 11L BW3.5/072 Brine well Eco 30L, Eco + 24L 22 H1016/4 Brine well cap, bottom 23 38522 Drain hose to be ordered per meter 24 74163 Air gap with double hose barb 25 38521 Clamp, drain hose (4x) 26 39105 Brine cabinet, mini Eco 11L, Eco 14L, Eco + 11L 39106 Brine cabinet, maxi Eco 30L, Eco + 24L 27 38547 Screw rivet 28 38532 Overflow assembly (*) Recommended Spare Part Page 25

EXPLODED VIEW - VALVE BODY ASSEMBLY - ECO Page 26

EXPLODED VIEW - VALVE BODY ASSEMBLY - ECO Item PN Description Remark (*) 1 15/90 Screw, solenoid retainer (4x) 2 413/134/24 Solenoid 3 541/229 Retainer, solenoid 4 413/58 Guide, solenoid 5 413/62 Spring, solenoid plunger 6 74099 Plunger, solenoid 7 74098 Diaphragm, solenoid 8 15/222 Screw, back cap (4x) 9 541/286/3 Back cap 10 74258 Brine elbow 11 74022 Brine draw restrictor 1,0 mm (black) 12 541/275 Check ball 13 568/385/2/A Refill flow control 0,25 gpm 14 541/206 Gasket, back cap 15 541/239 Spring, check disc 16 541/246 Check disc 17 15/89 Screw, cover plate (3x) 18 541/221 Cover plate, injector 19 428/5 Injector disc #5 20 541/325 Gasket, injector 21 74179 Filter, injector 22 72609 Locking plate, drain flow adjuster 23 15/76 Screw, locking plate 24 541/254 Spring clip 25 186/118 O-ring, brine plug 26 541/273 Brine plug 27 72467 Union gasket (2x) 28 72542 Elbow, inlet 29 19/19 Clip, drain flow adjuster 30 186/134 O-ring, drain flow adjuster (2x) 31 541/238 Drain flow adjuster 32 529/244 O-ring, drain port 33 467/216 Seal, body stem 34 72605 Body stem 35 185/024/1 O-ring, seat insert (small) 36 541/204 Seat insert 37 185/029/1 O-ring, seat insert (large) 38 72602 Main diaphragm 39 72507 Retainer, main diaphragm 40 72245 Washer, main diaphragm 41 72552 Screw, main diaphragm 42 516/221 Spring, main diaphragm 43 15/90 Screw, adapter ring (2x) 44 185/67/4 O-ring, tank 45 541/232 Adapter ring 46 185/214/1 O-ring, riser tube 47 541/218 Riser insert 1,050 48 185/029/1 O-ring, riser insert 49 541/257/1 Valve body (incl. 467/216) 50 72543 Elbow, outlet 51 72544 Impeller 52 72545 Hub, Impeller A RK/413 Repair kit solenoid diaphragm B RK/541/244 Repair kit body stem and seat C 72611 Repair kit body stem (*) Recommended Spare Part Page 27

EXPLODED VIEW - VALVE BODY ASSEMBLY - ECO + Page 28

EXPLODED VIEW - VALVE BODY ASSEMBLY - ECO + Item PN Description Remark (*) 1 15/90 Screw, solenoid (6x) 2 413/134/24 Solenoid (2x) 3 541/229 Retainer, solenoid 4 413/58 Guide, solenoid (2x) 5 413/62 Spring, solenoid plunger (2x) 6 74099 Plunger, solenoid (2x) 7 74098 Diaphragm, solenoid (2x) 8 15/222 Screw, back cap (4x) 9 541/274/3 Back cap 10 74258 Brine elbow 11 74022 Brine draw restrictor 1,0 mm (black) 12 541/275 Check ball 13 568/385/2/A Refill flow control 0,25 gpm 14 541/206 Gasket, back cap 15 541/239 Spring, check disc 16 541/246 Check disc 17 15/89 Screw, cover plate (3x) 18 541/221 Cover plate, injector 19 428/5 Injector disc #5 20 541/325 Gasket, injector 21 74179 Filter, injector 22 72609 Locking plate, drain flow adjuster 23 15/76 Screw, locking plate 24 541/254 Spring clip 25 186/118 O-ring, brine plug 26 541/273 Brine plug 27 72467 Union gasket (2x) 28 72542 Elbow, inlet 29 19/19 Clip, drain flow adjuster 30 186/134 O-ring, drain flow adjuster (2x) 31 541/238 Drain flow adjuster 32 529/244 O-ring, drain port 33 467/216 Seal, body stem 34 72605 Body stem 35 185/024/1 O-ring, seat insert (small) 36 541/204 Seat insert 37 185/029/1 O-ring, seat insert (large) 38 72602 Main diaphragm 39 72507 Retainer, main diaphragm 40 72245 Washer, main diaphragm 41 72552 Screw, main diaphragm 42 516/221 Spring, main diaphragm 43 15/90 Screw, adapter ring (2x) 44 185/67/4 O-ring, tank 45 541/232 Adapter ring 46 185/214/1 O-ring, riser tube 47 541/218 Riser insert 1,050 48 185/029/1 O-ring, riser insert 49 541/257/1 Valve body (incl. 467/216) 50 72543 Elbow, outlet 51 72544 Impeller 52 72545 Hub, Impeller A RK/413 Repair kit solenoid diaphragm B RK/541/244 Repair kit body stem and seat C 72611 Repair kit body stem (*) Recommended Spare Part Page 29

EXPLODED VIEW - SLI-CS - VALVE HEAD ASSEMBLY Item PN Description Remark (*) 1 15/87 Screw, valve head 2 72216 Valve head 3 541/300/G Drain flow control 2,0 gpm Eco + 11L, Eco + 15L, Eco + 20L 541/300/J Drain flow control 2,6 gpm Eco + 26L 4 185/115/1 O-ring, drain line adaptor 5 74018 Nut, drain solenoid 6 74016 Drain line adaptor 7 74019 Gasket, drain solenoid 8 74023 Drain solenoid (*) Recommended Spare Part Page 30

EXPLODED VIEW - SLI-BBS - VALVE HEAD & TIMER ASSEMBLY Item PN Description Remark (*) 1 72263 Twist lock clamp, power cord 2 70971 Power cord 3 72519 Flow meter cable 4.a 71681 Backwash solenoid cable (black) Eco + 4.b 71682 Refill solenoid cable (white) 5 72561 Drain solenoid cable 6 74023 Drain solenoid 7 74019 Gasket, drain solenoid 8 74016 Drain line adaptor 9 74018 Nut, drain solenoid 10 185/115/1 O-ring, drain line adaptor 11 541/300/J Drain flow control 2,6 gpm Eco + 11L, Eco + 24L 12 72216 Valve head 13 74262 Screw, timer housing (2x) Standard metric thread (ISO) 14 74189 Timer mounting bracket 15 15/87 Screw, valve head (4x) 16 28/8/28 Strain relief (2x) 17 74026 PCB housing back 18 15/102 Screw, PCB (2x) 19 74280 Printed Circuit Board Eco 74279 Printed Circuit Board Eco + 20 74231 PCB housing front assembly Standard metric thread (ISO) Page 31

TECHNICAL DATA - SLI-CS-ECO Technical specifications: Model SLI-CS-Eco Resin (Ltr) 11 14 17 24 30 Operating pressure min/max (bar) 1,4/8,3 Operating temperature min/max ( C) 2/48 Electrical connection (V/Hz) 230/50 (1) Maximum power consumption (VA) 17 Hydraulic connection inlet/outlet ¾ BSP Male (1) Supplied with 24V transformer Performances @ 3 bar operating pressure (2) : Model SLI-CS-Eco Resin (Ltr) 11 14 17 24 30 Nominal exchange capacity (m³x f) 50 63 87 122 153 Nominal exchange capacity (m³x d) 28 35 49 70 87 Service flow rate @ p 1 bar (m³/hr) 2,3 2,3 2,1 1,9 2,0 Recommended maximum service flow (m³/hr) (3) 1,1 1,4 1,7 2,4 3,0 Salt usage per regeneration (kg) (4) 1,4 1,8 2,1 3,0 3,8 Rinse water usage per regeneration (Ltr) (4) 61 64 78 117 144 (2) Indicative numbers, performances depending on operating conditions and water quality (3) Flow rate at which softening process is still executed adequately (4) Maximum salt/water usage as brining is proportional (minimum of 60%) Dimensions & weights: Model SLI-CS-Eco Resin (Ltr) 11 14 17 24 30 Width (mm) (W) 352 352 352 391 391 Height (mm) (H) 546 546 680 963 963 Depth (mm) (D) 442 442 442 467 467 Depth, including bypass (mm) 525 525 525 550 550 Height inlet/outlet (mm) 454 454 607 846 846 Height inlet/outlet, including bypass (mm) 460 460 613 852 852 Weight (kg) 19,5 21,5 25,0 35,5 41,0 Weight, including bypass (kg) 20,0 22,0 25,5 36,0 41,5 Maximum salt storage capacity (kg) 25 25 37 65 65 Page 32

TECHNICAL DATA - SLI-CS-ECO + Technical specifications: Model SLI-CS-Eco + Resin (Ltr) 11 14 17 24 Operating pressure min/max (bar) 1,4/8,3 Operating temperature min/max ( C) 2/48 Electrical connection (V/Hz) 230/50 (1) Maximum power consumption (VA) 21 Hydraulic connection inlet/outlet ¾ BSP Male (1) Supplied with 24V transformer Performances @ 3 bar operating pressure (2) : Model SLI-CS-Eco + Resin (Ltr) 11 14 17 24 Nominal exchange capacity (m³x f) 50 63 87 122 Nominal exchange capacity (m³x d) 28 35 49 70 Service flow rate @ p 1 bar (m³/hr) 2,3 2,1 2,1 2,1 Recommended maximum service flow (m³/hr) (3) 1,1 1,4 1,7 2,4 Salt usage per regeneration (kg) (4) 1,4 1,8 2,1 3,0 Rinse water usage per regeneration (Ltr) (4) 110 113 146 186 (2) Indicative numbers, performances depending on operating conditions and water quality (3) Flow rate at which softening process is still executed adequately (4) Maximum salt/water usage as brining is proportional (minimum of 60%) Dimensions & weights: Model SLI-CS-Eco + Resin (Ltr) 11 14 17 24 Width (mm) (W) 352 352 391 391 Height (mm) (H) 546 680 963 963 Depth (mm) (D) 442 442 467 467 Depth, including bypass (mm) 525 525 550 550 Height inlet/outlet (mm) 454 607 846 846 Height inlet/outlet, including bypass (mm) 460 613 852 852 Weight (kg) 19,5 22,5 30,0 36,5 Weight, including bypass (kg) 20,0 23,0 30,5 37,0 Maximum salt storage capacity (kg) 25 37 65 65 Page 33

TECHNICAL DATA - SLI-BBS-ECO Technical specifications: Model SLI-BBS-Eco Resin (Ltr) 11 14 30 Operating pressure min/max (bar) 1,4/8,3 Operating temperature min/max ( C) 2/48 Electrical connection (V/Hz) 230/50 (1) Maximum power consumption (VA) 17 Hydraulic connection inlet/outlet (1) Supplied with 24V transformer Performances @ 3 bar operating pressure (2) : ¾ BSP Male Model SLI-BBS-Eco Resin (Ltr) 11 14 30 Nominal exchange capacity (m³x f) 50 63 163 Nominal exchange capacity (m³x d) 28 35 93 Service flow rate @ p 1 bar (m³/hr) 2,3 2,3 2,0 Recommended maximum service flow (m³/hr) (3) 1,1 1,4 3,2 Salt usage per regeneration (kg) (4) 1,4 1,8 4,0 Rinse water usage per regeneration (Ltr) (4) 59 64 156 (2) Indicative numbers, performances depending on operating conditions and water quality (3) Flow rate at which softening process is still executed adequately (4) Maximum salt/water usage as brining is proportional (minimum of 60%) Dimensions & weights: Model SLI-BBS-Eco Resin (Ltr) 11 14 30 Brine tank width x depth (mm x mm) 290x310 Brine tank height (mm) 435 435 905 System depth (pressure tank & valve) (mm) 278 278 278 System depth, including bypass (mm) 380 380 380 System height (mm) 545 545 950 Height inlet/outlet (mm) 452 452 857 Height inlet/outlet, including bypass (mm) 458 458 863 Weight (kg) 15,5 18,5 35,5 Weight, including bypass (kg) 16,0 19,0 36,0 Maximum salt storage capacity (kg) 30 30 65 Page 34

TECHNICAL DATA - SLI-BBS-ECO + Technical specifications: Model SLI-BBS-Eco + Resin (Ltr) 11 24 Operating pressure min/max (bar) 1,4/8,3 Operating temperature min/max ( C) 2/48 Electrical connection (V/Hz) 230/50 (1) Maximum power consumption (VA) 21 Hydraulic connection inlet/outlet ¾ BSP Male (1) Supplied with 24V transformer Performances @ 3 bar operating pressure (2) : Model SLI-BBS-Eco + Resin (Ltr) 11 24 Nominal exchange capacity (m³x f) 50 122 Nominal exchange capacity (m³x d) 28 70 Service flow rate @ p 1 bar (m³/hr) 2,3 2,1 Recommended maximum service flow (m³/hr) (3) 1,1 2,4 Salt usage per regeneration (kg) (4) 1,4 3,0 Rinse water usage per regeneration (Ltr) (4) 110 186 (2) Indicative numbers, performances depending on operating conditions and water quality (3) Flow rate at which softening process is still executed adequately (4) Maximum salt/water usage as brining is proportional (minimum of 60%) Dimensions & weights: Model SLI-BBS-Eco + Resin (Ltr) 11 24 Brine tank width x depth (mm x mm) 290x310 Brine tank height (mm) 435 930 System depth (pressure tank & valve) (mm) 278 278 System depth, including bypass (mm) 380 380 System height (mm) 545 950 Height inlet/outlet (mm) 452 857 Height inlet/outlet, including bypass (mm) 458 863 Weight (kg) 16,0 30,0 Weight, including bypass (kg) 16,5 30,5 Maximum salt storage capacity (kg) 30 65 Page 35

Page 36

Page 37

Page 38

Page 39

Manufactured & Assembled by erie water treatment a division of Aquion, Inc. www.eriewatertreatment.com