Rev D 3/20/17

Similar documents
NXSMP-LMI LOW MOUNT INDOOR SENSOR MODULE

Automatic Dimming Mirror with HomeLink

2 x screws. 2 x wall plugs

Wireless External Alarm

Wireless Weather Station

Optima ZigBee Thermostat

1100D Wireless Receiver

Model:T83646v2 Quick Setup Guide DC: WIRELESS WEATHER STATION

Atomic Digital Office Clock

QUICK START GUIDE. Lono, LLC 686 East 110 South, Suite 102 American Fork, UT 84003

SZ-PIR04N ZigBee Motion Detector Installation Guide

OPERATION MANUAL WARNING TO REDUCE THE RISK OF INJURY OR PRODUCT DAMAGE, READ OPERATION MANUAL PRIOR TO OPERATING PRODUCT.

Smart THERMOSTAT. Installation Manual

Smart Hub THERMOSTAT. Installation Manual

ADT. Pulse 2017ADT LLC

1100X Wireless Receivers

TP WEM01 A Carrierr Côr Thermostat AC/HP Wi-Fir Thermostat Performance Series. Installation Guide

Evolve 5.5 cu. ft. Medical-grade Undercounter Refrigerator

XHS1-TY / MP-841 ZigBee Home Automation 1.2 Wireless Digital Pet Immune PIR Detector

Low Voltage Fan Coil Thermostat ST101ZB. Quick Start Guide. For other language versions, please visit

Embedded Door Sensor. User's Manual. Model SS881ZB. For other language versions, please visit:

1134 Wireless Wiegand Module INSTALLATION AND PROGRAMMING GUIDE

Wi-Fi DOOR/WINDOW SENSOR

S541.RF 4G Product Guide

Intelligent Home Solutions Quick Start Guide. Monitor your home from anywhere with your smartphone

InTemp CX Temperature Logger (CX40x) Manual

Wireless Outdoor Air Reset Adaptor PN:

Touchscreen Comfort Control

ShockLink. Important Product Information.

Installation Guide. Model TBZ48A Battery Powered Z-Wave Thermostat. This thermostat is compatible with most HVAC systems, including the following:

Water Sensor. Model CFWS10

Impassa CDMA Module INSTALLATION GUIDE

Smoke Bridge Owner s Manual

Intelli-Time Alarm Clock model 13041RM

WM3000 WIRELESS MODULES

nextouch Touchscreen and Push Button Access Cylindrical Lock Installation and Programming Instructions

EL-TSTAT Owner s Manual

EN1221S-60 Waterproof Pendant Installation and Operation Manual

HOBO MX Temp/RH Data Logger (MX1101) Manual

SkyNEST WASP Portable Kit, Smart Receiver and SCADA Gateway with Solar Panel USER MANUAL

ecobee 3 Quick Start Guide Installation Guide DRAFT

Pet Immune SAW PIR Motion Sensor

1 Copyright 2015 Alarm.com. All rights reserved. Rev 3.4

Yale Real Living Push Button Deadbolt Installation and Programming Instructions (YRD210)

1 Copyright 2014 Alarm.com. All rights reserved. Rev 3.3

Tech Support Line: (715) Concord 4 RE927X

1164/1164NS Wireless Smoke Detector INSTALLATION AND PROGRAMMING GUIDE

Draft - develop and review

Caught a critter in the act?

PET IMMUNE PIR MOTION DETECTOR

Yale Real Living Push Button Lever Installation and Programming Instructions (YRL210)

TX3 Series. TX3 InSuite. User Guide

GLAS. Installation Instructions

XV 210 GPRS Control Panel

OPTIMA ZigBee Thermostat

Home Comfort Control with Wi-Fi Model 8910W READ AND SAVE THESE INSTRUCTIONS. Owner s Manual. Includes Operating Instructions and Warranty Information

Features and content. This is where air comes into your detector.

Technical support is also available by or by phone: (North America) (International)

XT-iP 210 Control Panel

SuperCELL Model SC500-H-SM User s Information

Yale Real Living Key Free Push Button Deadbolt B1L Installation and Programming Instructions

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

DT8050A DUAL TEC Motion Sensor with Anti-Mask - Installation Instructions

Yale Real Living Key Free Push Button Deadbolt B1 with Installation and Programming Instructions

Yale Real Living Key Free Touchscreen Deadbolt Installation and Programming Instructions (YRD240)

XL200L/600L/700L GPRS Control Panel

FTS05 / FTS05P - Wireless Flood and Temperature Sensor, User Manual

GARAGE DOOR OPENER KIT

FTN-RRHW/FTN-RRIX FTN-RR2G/FTN-RRDS

INSTEON Wireless Thermostat Owner Manual (#2441ZTH)

Yale Assure Lock Push Button Deadbolt Installation and Programming Instructions ( YRD216/YRD416)

Smart Radon Detector with Indoor Air Quality Sensors

Yale Real Living Touchscreen Deadbolt Installation and Programming Instructions (YRD220)

Smart Radon Detector with Indoor Air Quality Sensors Version 1, May 8, 2018

RE6100 Series Helix Security and Automation Platform E I D

1164/1164NS WIRELESS SMOKE DETECTOR

Yale Real Living Touchscreen Lever Installation and Programming Instructions (YRL220)

Contents. User Manual GA-U-1. VultureNet: Long Range System

RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide

How to install your ecobee4

Yale Real Living Assure Lock Push Button Deadbolt Installation and Programming Instructions (YRD216)

HomeLink Wireless Control System

THB4002. GoTemp Food Infrared Thermometer With Laser Sighting And Thermocouple Jack User Guide. Measuring Temperature The Smart Way.

RMS/RPX Reader. User Manual

ZTS-500US Z-Wave Smart Thermostat

Door/Window Sensor Installation Instructions

Model SWH-4000 Multi-Technology Mullion 125 KHz and MHz (Flex) Reader Installation Guide. Version A0 Part Number UM-104 September 2005

Monnit Wireless Local Alert. User s Guide

EN1221S-60 Waterproof Pendant Installation and Operation Manual

EL-TSTAT-8820 Owner s Manual

Installation Instructions

XTO-IP ALARM PANEL. Description. Supervised Wireless Technology. Features

RF2352A, HC2351AC (Discontinued), HC2352AC

Install Guide TP-2014-IG-V02

Yale Assure Lock Push Button Deadbolt Installation and Programming Instructions ( YRD216/YRD416)

Nest x Yale Lock Programming/Troubleshooting Guide

Installation and Operation Manual. Model: STI TRIGGERED OUTPUT PLUG 12VDC, 75mA, 3 SEC. EMBOSSED PROGRAMMING

INTRODUCTION. Industry Canada: Canadian ID: 6982A-YRHCPZW0 (Z-Wave); 6982A-YRHCPZB0 (Zigbee)

Installer Guide smart connect

Model SWH-3000 Proximity Multi-Frequency 125KHz & 13.56MHz (Fixed) Reader Installation Guide. Version A0 Part Number UM-102 September 2005

Transcription:

Rev D 3/20/17 Installation and Operating Instructions ADAEZ Wireless Interface Module (WIM) Note Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this device. This device complies with part 15 of the FCC Rules. Operation is subject to the condition that this device does not cause harmful interference. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. This device complies with Industry Canada s licence-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause interference; and (2) This device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence. L exploitation est autorisée aux deux conditions suivantes : 1) l appareil ne doit pas produire de brouillage; 2) l appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d en compromettre le fonctionnement. To obtain the latest manual and template revisions or to view installation and programming videos go to www.nortondoorcontrols.com. For technical support call 800-438-1951 x 4. 1 of 13

Installation and Operating Instructions 1. PURPOSE 1.1 Discussion This manual provides system description, installation instructions, operating instructions, and troubleshooting recommendations for the ADA EZ Wireless Interface Module (refered to as the WIM). The ADA EZ WIM allows the ADA EZ swing door operator to interface with the ADA EZ wired or wireless pushbuttons, wireless remote, an electric lock, fire panel, access control, and an outside pushbutton disable contact. 1.2 Applicability 2. PREREQUISITES This manual is applicable to the ADA EZ series Wireless Interface Module. 2.1 An ADA EZ swing door operator installed according to ADA EZ Pro Installation and Operating Instructions p/n 700002 with optional Hardwire Kit p/n 1015 or 24VDC (500ma minimum) power supply by others. 2.2 Plastic electrical enclosure for WIM. 2.3 12 or 24V AC or DC to power the WIM. 2.4 24VDC is REQUIRED if the ADA EZ swing door operator will be powered thorough the WIM with the supplied cable 2.5 Protective barrier (caution/warning tape) has been set up to prevent unauthorized access to work area. 2.6 The door has been secured to prevent unexpected opening or closing during installation. 3. PRECAUTIONS 3.1 This product is intended for interior use only. 3.2 An operating door creates pinch hazards. Be careful making operating adjustments while the door is moving. 3.3 The transformer wiring must not be concealed behind walls or routed through doorways, window openings, walls, ceilings, or floors. Also, this wiring must be secured to prevent it from becoming entrapped in the moving parts of the operator or door. 2 of 13

4. SYSTEM DESCRIPTION 4.1 General The ADA EZ WIM allows the ADA EZ swing door operator to interface with: ADA EZ wireless (RF) push buttons or Wired push buttons ADA EZ wireless (RF) hand held transmitter Electric Lock Access Control Fire Panel Switch to disable outside pushbutton 4.2 Inputs and Outputs 4.2.1 Pushbuttons: A wired and wireless input is provided for an and an pushbutton. An optional handheld transmitter p/n HAND-HELD-TX 1031may be connected to either the or rf pushbutton. 4.2.2 Operator Connection: A connector is provided to plug in the ADA EZ swing door operator into the WIM module 4.2.3 Access Control: Contacts are provided to interface the WIM with access control. 4.2.4 Lock Interface: Contacts are provided to control an electrical lock. 4.2.5 Lock Power: Contacts are provided to power an electric lock. 4.2.6 Outside Pushbutton Disable: A contact is provided to disable any input from an outside pushbutton. 4.2.7 Power Input: A power input connector is provided to power the WIM by the optional hardwire kit p/n KIT-HDWR 1015P. 4.2.8 Signal Delay: A switch is provided to enable a 1 second delay before sending an activate signal to the door operator 5. INSTALLATION INSTRUCTIONS 5.1 Mount the WIM enclosure in a remote location as desired. NOTE The ADA EZ WIM may be powered by 12 or 24 Volts AC or DC current. If the door operator will be powered directly from the WIM, a 24VDC 750ma (minimum) power supply is required. 5.2 Provide power to the WIM. (Refer to Figure 1) 5.2.1 If the Optional 1015P hardwire kit is used to power the WIM and door operator, plug the provided GREEN connector into the power port as shown. 5.2.2 If Power supply is by others, connect the power supply using the provided GREEN connector. If a DC power supply is used connect the ground to the terminal marked - and the positive to the terminal marked +. 5.2.3 If the operator will be powered through the WIM, use the supplied Operator Wire Harness (p/n 1036) to power the Operator. 3 of 13

Figure 1. Wiring the WIM and Operator NOTE The ADA EZ swing door operator is shipped with wireless RF pushbuttons that are pre-programmed to the operator. The RF codes MUST be erased from the ADA EZ swing door operator for proper operation. 5.3 Erase All RF codes from the door operator 5.3.1 Refer to Figure 2 and Remove the bottom cover from the door operator to access the Setup board. 5.3.2 Refer to Figure 3. PRESS and HOLD the LEARN button, PRESS and RELEASE the RESET button on the setup board. 5.3.3 LEDs DS8 through DS11 shall flash GREEN. 4 of 13

Figure 2. Remove Bottom Cover Figure 3. Erase learned RF Codes 5 of 13

5.1 Learn WIM module to door operator 5.1.1 Refer to Figure 3 and PRESS and HOLD the LEARN button until on the Operator Control board until LEDs DS8-DS11 Flash Green. 5.1.2 Refer to Figure 4 and PRESS and RELEASE the button on the WIM. 5.1.3 On the Setup board, LEDs DS8 through DS11 shall rapidly flash GREEN 3 times. Figure 4. Learn the WIM to the Operator PRESS & RELEASE TO LEARN HOLD TO ERASE PRESS & RELEASE TO LEARN HOLD TO ERASE DOOR FIRE PANEL IN COM OUT ACCESS CTR DELAY NO COM NC IN 12 OR 24V DISABLE 5.2 Connect Pushbuttons to WIM NOTE The pushbutton is considered to be an input from the SECURE side of the door. An activation will switch the contact, the ACCESS CTR output contact, and send an activation signal to the door operator. The pushbutton is considered to be an input from the NON-SECURE side of the door. An activation will switch the contact, the ACCESS CTR output contact, and send an activation signal to the door operator ONLY if the ACCESS CTR INPUT contact is CLOSED. 6 of 13

5.2.1 Refer to Figure 4. If the pushbuttons will be hard wired, connect the and pushbuttons to the WIM module contacts labeled and. 5.2.2 If the pusbutton will be connected using RF activation, it must be learned to the WIM. a. Refer to Figure 4 and PRESS and RELEASE the button. b. The Audible will beep and the LED above the button will flash RED if no RF signals have been learned or GREEN if an RF button is already stored in memory. If the audible sounds a steady beep and the RED LED lights flashes 4 times rapidly the RF memory is full and must be reset in order to learn a new RF activation signal. c. Press and release the pushbutton (or optional handheld transmitter or optional pushbutton) 2 times. d. The LED will flash and the audible will beep 4 times if the RF signal was successufully learned. e. If the pushbutton is not learned the audible will beep for two seconds and exit learn mode. 5.2.3 If the pusbutton will be connected using RF activation, it must be learned to the WIM. a. Refer to Figure 4 and PRESS and RELEASE the pushbutton. b. The Audible will beep and the LED above the button will flash RED if no RF signals have been learned or GREEN if an RF button is already stored in memory. If the audible sounds a steady beep and the RED LED lights flashes 4 times rapidly the RF memory is full and must be reset in order to learn a new RF activation signal. c. Press and release the pushbutton (or optional handheld transmitter or optional pushbutton) 2 times. d. The LED will flash and the audible will beep 4 times if the RF signal was successufully learned. e. If the pushbutton is not learned the audible will beep for two seconds and exit learn mode. 5.3 Erasing RF codes from the WIM 5.3.1 Refer to Figure 4 and PRESS and HOLD the pushbutton on the WIM for 5 seconds 5.3.2 The LED will flash RED 4 times and the audible will beep for 4 seconds 7 of 13

Figure 5. Connecting an Electric Lock Series Installation PRESS & RELEASE PRESS & RELEASE TO LEARN TO LEARN HOLD TO ERASE HOLD TO ERASE DOOR FIRE PANEL IN COM OUT ACCESS CTR ELECTRIC DELAY NO COM NC IN 12 OR 24V DISABLE SUPPLY Figure 6. Connecting an Electric Lock Parallel Installation PRESS & RELEASE PRESS & RELEASE TO LEARN TO LEARN HOLD TO ERASE HOLD TO ERASE DOOR FIRE PANEL IN COM OUT ACCESS CTR ELECTRIC DELAY NO COM NC IN 12 OR 24V DISABLE SUPPLY 8 of 13

5.3.3 Refer to Figure 4 and PRESS and HOLD the pushbutton for 5 seconds 5.3.4 The LED will flash RED 4 times and the audible will beep for 4 seconds 5.3.5 All learned RF codes are now erased. 5.4 Connect an Electric Lock to the WIM NOTE The electric lock contact will switch state when the pushbutton is activated OR the Access Control input contact is CLOSED. 5.4.1 An electric lock may be connected to the WIM as shown in Series as shown in Figure 5 or in Parallel as shown in Figure 6. If the Parallel installation shown in Figure 6 is used, the supplied jumper must be removed from the WIM lock power connector. 5.4.2 A normally open or normally closed contact are provided for fail safe or fail secure lock installation. 5.4.3 An optional signal delay is provided to add a one second time delay between recieiving an activate signal and sending an activate signal to the door operator. This allows additional time for the lock to unlock before the door starts to open. If the lock delay is required, refer to Figure 5 and move the signal delay switch to the top (ON) position. 5.1 Connect the WIM to Access Control, Alarm Panel, or Fire Panel. NOTE Closing the ACCESS CTRL IN contact will switch the state of the contact and enable the pushbutton. The ACCESS CTRL OUT contract will close when the WIM module has received an authorized signal to switch the contact. Closing the FIRE PANEL contact will prevent the door operator from accepting an activate signal or will close the door operator if it is in the open position. 5.1.1 Refer to Figure 7 and connect the optional Access Control Input contact, Alarm Panel Output contact, or Fire Panel Input contact. 5.2 Connect the PUSH DISABLE NOTE Closing the PUSH DISABLE contact will prevent the WIM from accepting an activation signal from the pushbutton. 5.2.1 Refer to Figure 7 and Connect the PUSH DISABLE. 9 of 13

Figure 7. Optional Interface Connections 10 of 13

5.3 Wiring diagrams for Common Applications Figure 8. Electric Strike with RF or Wired pushbuttons No Access Control WIRELESS RF OPTIONAL HARDWIRED OPTIONAL HARDWIRED PRESS & RELEASE PRESS & RELEASE TO LEARN TOLEARN HOLD TO ERASE HOLD TOERASE DELAY DOOR FIRE PANEL IN COM OUT ACCESS CTR NO COM NC FAIL SECURE FAIL SAFE IN 12 OR 24V DISABLE SUPPLY 11 of 13

Figure 9. Electric Strike with RF or Wired pushbuttons & Card Reader (or other access control) WIRELESS RF OPTIONAL HARDWIRED OPTIONAL HARDWIRED PRESS & RELEASE PRESS & RELEASE TO LEARN TOLEARN HOLD TO ERASE HOLD TOERASE DELAY DOOR FIRE PANEL IN COM OUT ACCESS CTR NO COM NC FAIL SECURE FAIL SAFE CARD READER (ACCESS CONTROL) ALARM PANEL IN 12 OR 24V DISABLE SUPPLY 12 of 13

Figure 10. Electric Strike with RF or Wired pushbuttons and Outside Button Disable Switch WIRELESS RF OPTIONAL HARDWIRED OPTIONAL HARDWIRED PRESS & RELEASE PRESS & RELEASE TO LEARN TOLEARN HOLD TO ERASE HOLD TOERASE DOOR FIRE PANEL IN COM OUT ACCESS CTR DELAY NO COM NC FAIL SECURE FAIL SAFE SUPPLY IN 12 OR 24V DISABLE DISABLE SWITCH 13 of 13