Part B - Health Facility Briefing and Planning. PLANNING Operational Models Functional Areas Functional Relationships

Similar documents
36.0 Sterile Supply Unit (SSU)

Part B Health Facility Briefing & Design 150 Linen Handling Unit

Guidelines for Ideal Layout for an Operating Theater Complex. Dr.R.D.Ravindran Aravind Eye Hospital Madurai

MARSHALLTOWN MEDICAL AND SURGICAL CENTER LAUNDRY/LINEN SERVICES. SUBJECT: Infection Control POLICY NO: 106

Australasian Health Facility Guidelines. Part D - Infection Prevention and Control D Physical Environment

PENNSYLVANIA. Downloaded

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN COMPANION ANIMAL VETERINARY CLINICS/HOSPITALS

Mini Guide to hygienic laundry practices. based on the RABC system/en 14065

Part B Health Facility Briefing & Design 290 Waste Management Unit

Australasian Health Facility Guidelines

INFECTION PREVENTION AND CONTROL ENVIRONMENTAL AUDIT TOOL

Planning for the optimal sluice room

Infection Control Manual Residential Care Part 3 Infection Control Standard IC9: Environmental

Fiona Collins Liliana Donatelli Andrew Smith

Australasian Health Facility Guidelines

LAUNDRY POLICY Page 1 of 6 Reviewed: February 2017

Food Premises - Structural Specifications

NORTH CAROLINA. Downloaded (l) For each nursing unit, or fraction thereof on each floor, the following shall be provided:

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN COMPANION ANIMAL VETERINARY CLINICS/HOSPITALS

Christina Bradley Laboratory Manager Hospital Infection Research Laboratory Queen Elizabeth Hospital Birmingham, UK

Opening a Personal Service Premises in Manitoba

Device Reprocessing Checklist Scoring Matrix 1=low 5=high

INSTRUCTIONS FOR CLEANING AND STERILIZATION OF ALL B.BRAUN AESCULAP HAND HELD SURGICAL INSTRUMENTS AND POWER PRODUCTS (UNITED KINGDOM REQUIREMENTS)

45.1 Introduction Planning. Bulk Waste Movement. Clinical Waste Waste Management Unit

Washroom. PURPOSE: To provide clean washrooms for staff, visitors and patients MATERIALS: 19-1

DHS Design guidelines for hospitals and day procedure centres. Part E- Building Services and Environmental Design

Washer disinfectors. MLC Series. for transfer trolleys, sterile containers and bulky items

room data sheet TAMURA HOUSE 396 POWELL STREET, VANCOUVER, BC 1/8 RESIDENTIAL ROOM RM DIVISION ELEMENT REQUIREMENT

MOLSON S BANK BUILDING 166 EAST HASTINGS STREET, VANCOUVER, BC

SECTION LABORATORY EQUIPMENT CONSTRUCTION STANDARD PART 1: GENERAL Scope of Standard

FOOD ESTABLISHMENT CONSTRUCTION GUIDE Revised December 19, 2011 Reviewed January 10, 2014

Preview Copy.

المملكة العربية السعودية وزارة الصحة اإلدارة العامة لمكافحة عدوى المنشئات الصحية

FOOD SERVICE EQUIPMENT; EXISTING CONSTRUCTION. Subpart 1. Food service equipment. All food service

The individual indicated in the responsible person column must decontaminate the item as indicated in the method column.

Hospital ventilation & infection prevention

Factory & Hospital hygiene, Chap 21(7 th edition) Principles of GMP, Chap 23 (8 th edition )

CBC s Inspection Findings and Possible Remedies Thereto

2. Read and fill out the enclosed form completely. Your plans will not be reviewed if the procedures listed here are not observed.

room data sheet MARBLE ARCH HOTEL 518 RICHARDS STREET, VANCOUVER, BC 1/14 RESIDENTIAL ROOM RM DIVISION ELEMENT REQUIREMENT

room data sheet GASTOWN HOTEL 110 WATER STREET, VANCOUVER, BC 1/11 RESIDENTIAL ROOM RM DIVISION ELEMENT REQUIREMENT

Housekeeping and Laundry Ulrika Ransjö

room data sheet CORDOVA RESIDENCE 1/11 54 EAST CORDOVA STREET, VANCOUVER, BC RESIDENTIAL ROOM RM DIVISION ELEMENT REQUIREMENT

4.0 SERVICES AND SCHEDULE

EN l Senking Batch Transfer Drying Tumbler DT Senking Batch Transfer Drying Tumbler DT High performance with less energy

Getinge 9100E Cart Washer-Disinfector. Your safe, efficient and sustainable cleaning solution

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN VETERINARY EQUINE PRACTICE

MINIMUM CONSTRUCTION STANDARDS AND SPECIFICATIONS CHECKLIST

Bath Planning Worksheet

Housekeeping. Note. Areas that are not covered under contractor services must adhere to the same cleaning standards as specified in this section.

Scottish Health Planning Note 13. Part 2 Decontamination Facilities: Local Decontamination Units

RELIANCE VISION SINGLE-CHAMBER WASHER/DISINFECTOR

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN VETERINARY EQUINE PRACTICE

DRAFT. Module 4. Decontamination & Environmental Cleaning

JOB DESCRIPTION. Reports To : Laundry Supervisor, Assistant Director of Housekeeping, Director of Housekeeping

CHELAN COUNTY FIRE DISTRICT 5

TOE RIVER HEALTH DISTRICT PLAN REVIEW CHECKLIST

Part B Health Facility Briefing & Design 40 Catering Unit

Structural Guidelines. Food Service Establishments. Retail Food Stores

MAINE. Downloaded g. Maintain an effective pest control program so that the facility is free of pests and rodents;

Ventilation for Healthcare Facilities

MINIMUM CONSTRUCTION AND EQUIPMENT REQUIREMENTS FOR FOOD AND BEVERAGE ESTABLISHMENTS

Ventilation for Healthcare Facilities. Topics to be Covered

Agency for Health Care Administration

PIHA DUTIES HANDBOOK. 64 Glenesk Road, Piha

room data sheet ORANGE HALL 341 GORE AVENUE, VANCOUVER, BC 1/8 RESIDENTIAL ROOM RM DIVISION ELEMENT REQUIREMENT

Food Service Establishment Plan Review Form

Environmental Cleaning Tool Kit

TREATMENT ROOM DATA SHEETS

WORK IN THE DISINFECTION ROOM WITH WASHER-DISINFECTORS

Wet Loads presentation Tim Galekop Abstract 2006

An MRI Centre An MRI centre shall be defined as a facility with the following minimum requirements as listed in sections A to G below:

Element D Services Electrical ODG010107

THIS IS A DESIGN GUIDE NOT A SPECIFICATION. Montgomery County Public Schools Facilities Guide DIVISION 15 MECHANICAL

Pty. Ltd. 1. Classroom Cleaning Daily Wkly Mthly Other Vacuum and mop all hard surfaces Vacuum and spot clean all carpeted areas Remove any cobwebs Cl

Medikal Ürün Kataloğu Medical Products Catalogue. The Preference of Professionals

Institute of Decontamination Sciences Blackburn House, Redhouse Road, Seafield, Bathgate, West Lothian EH47 7AQ

IUSS HEALTH FACILITY GUIDES. Laundry and Linen Department. Gazetted. Supported by: 30 June Task Team: B:04

CITY OF GREATER GEELONG

MINNESOTA. Downloaded

Quality Products AHU Repair, Refurbishment and Replacement

APPLICATION FOR COSMETOLOGY/SPA PLAN REVIEW

SCHEDULE OF FINISHES AND OUTLINE SPECIFICATIONS

Windhill Old Road, Thackley, 899,950. Asking Price ABSOLUTELY STUNNING STONE BUILT PROPERTY 5 BEDROOMS, 4 BATHROOMS, 3 RECEPTIONS

Section 9 - Tumble Dryers. Tumble Dryers LEPH

Minimum Standards for Hairdressing Premises. Prepared by Palmerston North City Council Environmental Health

Clean Air Laminar Flow Ceiling CG 3 A CLEAN AIR WORLD. Draft-free, comfortable room climate. Minimal, undisruptive noise level

TARRANT COUNTY PUBLIC HEALTH DEPARTMENT fax FOOD ESTABLISHMENT REVIEW APPLICATION

HEALTHCARE SAFETY INSPECTION

Guidance on Environmental Requirements for Minor Surgery in General Practice

CLEANING INSTRUCTIONS

Washer disinfectors Small - Medium range

Coquille Indian Housing Authority Maintenance Report February 2017

The list is not exhaustive and where there is any doubt about the VAT status of items not included here please contact the UCL Tax Team.

Accurately With HSE COP PT 1 5

Washer disinfectors. > CSSD Range - Systems and Automations. devoted to hygiene. For the Environmentally conscious

Processing Instructions. Cleaning so easy.

5.1.2 Doors used by Patients Doors to rooms that are likely to be used by patients without staff assistance should be single or double swing type.

CENTRAL STERILE SUPPLY DEPARTMENT

Plan reviews are required for child care facilities that engage in diaper changing, meal preparation, and/or obtain drinking water from a well.

Transcription:

190 CENTRAL SUPPLY UNIT (CSSU) INDEX 190.1.00 Description INTRODUCTION General PLANNING Operational Models Functional Areas Functional Relationships DESIGN General Communications Finishes Building Service Requirements COMPONENTS OF THE UNIT Introduction Standard Components Non-Standard Components APPENDICES Schedule of Accommodation References and Further reading CSSU Flow Diagrams Functional Relationships Diagram INTRODUCTION 190.2.00 190.3.00 General A Hospital must provide adequate facilities for cleaning, sterilisation and storage of equipment and instruments to ensure the care and safety of patients, and the safety of staff, at all times. The sterilisation process may be carried out entirely or partially on-site, the latter relying on an external supply source to regularly restock the hospital sterile goods store. The scale of operation can be small or large, dependent upon the requirements of the serviced departments, for example, an Operating Unit requires the services of a Theatre Sterile Supply Unit (TSSU) or a full Central Sterile Supply Department (CSSD), whereas an Acute Ward requires only a basic Sterile Supply Service. PLANNING 190.4.00 Operational Models The size and role of the sterile goods supply service shall be clearly defined in the Operational Policy Statement. The following documents shall be referred to for design and operational standards: - Australian Standard 4187 - Cleaning, disinfecting and sterilising reusable medical and surgical instruments and equipment and maintenance of associated environments in Health Care Facilities - National Standard for the Operation of Sterile Supply Service in Health Care Facilities produced by the National Consultative Council for Therapeutic Goods, (NCCTG). Page 139 of 426

190.5.00 190.6.00 Functional Areas The Central Sterile Supply Unit will include the following functional areas or zones: - Receival Area where soiled articles for recycling are received on trolleys from Units throughout the facility - Cleaning Area where all articles are sorted, rinsed, ultrasonically cleaned or mechanically washed then mechanically dried; this area may also include cleaning of the delivery trolleys - Packing Area (Clean Workroom) where the clean instruments, equipment and other articles are sorted, counted and packaged for sterilising - Sterilising and Cooling Area where sterilisers are loaded, set into operation and unloaded following completion of the sterilising cycle - Despatch Area where sterile stock is held prior to despatch to Units in the facility; distribution trolleys may also be located in this area - Administrative Areas including Offices or Workstations - Staff Amenities which includes Staff Toilets, Change Rooms and Staff Rooms; these may also be shared with Operating Unit if convenient. ADMINISTRATIVE AREAS A separate room, or space within the Workroom, shall be provided for routine clerical/administrative procedures. The provision of a separate office will depend upon the size of the unit/department. An area for write-up and storage of stationery and files shall be provided. A pinboard/whiteboard should also be considered. 190.7.00 WORKROOM AREA A room shall be provided that contains hand-washing facilities, work space and equipment for terminal sterilising of medical and surgical equipment and supplies. Linen folding shall be carried out in a separate room, preferably the laundry. Where procedure packs are prepared in a sterile supply unit they shall be in a separate area to instrument preparation. The air handling system shall be filtered or discharged direct to the outside to prevent lint build-up and related industrial and fire safety problems. High level supply and low level exhaust is the recommended airflow pattern, with localised high level extraction for heat removal only. Special attention shall be given to the height and depth of workbenches to allow staff to work sitting or standing. 190.8.00 Views to the outside are considered highly desirable. 190.9.00 DISTRIBUTION A distribution point, if required, shall be provided in the form of a staffed counter or stable door, or a pass through cupboard from the sterile store into an adjacent service corridor. No general access is allowed to the CSSU. 190.10.00 STAFF AMENITIES Showers, toilets and secure lockers for staff employed in this area shall be provided. These facilities shall be conveniently located and may be shared with the Operating Unit staff in cases where the Sterile Supply Department is attached to the Operating Unit. A lunch room can be a shared central facility outside the Sterile Supply Department. Access to a training room in close proximity to CSSU for formal training activities is recommended. 190.11.00 Facilities shall also be provided in the Change Room to store caps, overalls and footwear protection. 'Barrier' principles are observed when entering the Page 140 of 426

unit. 190.12.00 STORAGE A room shall be provided for the storage of processed sterile packs etc. Ventilation, humidity and temperature control is required. Supply air pressure shall be positive with respect to surrounding areas and the level of filtration shall equal or exceed that of the Operating Room. Storage cupboards shall be fitted with doors. 190.13.00 190.14.00 A separate room shall be provided to store stock that is 'clean' but not sterile. Access to this room shall be provided from outside the unit/department for stocking, and from within the unit/department for drawing stock to process. Space shall also be provided for storing distribution trolleys as required. 190.15.00 Functional Relationships The Central Sterile Supply Unit (CSSU) should be located with direct or close access to the Operating Unit. It should have ready access to Supply Unit and Linen Handling Unit for delivery of supplies. Access to the CSSU should be restricted to authorised personnel only. DESIGN 190.16.00 190.17.00 190.18.00 190.19.00 General The planning of the facility must provide for separate clean and dirty working areas. Communications A telephone or intercom system should be installed within the Clean Workroom and/or Office to allow communication with outside personnel and departments, without breaching the "clean barrier" regime. Finishes Floor finishes shall be easy to clean. Welded sheet vinyl, coved up the wall, is recommended. Wall finishes shall also be easy to clean, with special consideration for damage by trolleys. Windows, if provided, must be unable to be opened. The ceiling shall be of a flush type and sealed against the walls. 190.20.00 190.21.00 Building Service Requirements AIR FILTRATION Where the Sterile Supply Unit is attached to an Operating Unit, ventilation shall be provided by a treated air supply, with air-conditioning to comply with AS 1386 and HEPA filters to comply with AS 1324. Refer to Part E - HVAC Services for more detailed information. LIGHTING Page 141 of 426

190.21.00 Light fittings shall be fully recessed and selected to prevent dust and insects from entering. 190.22.00 The light level shall be not less than 400 lux. 190.23.00 SIGNAGE Door signs are required to provide instruction as to the closed nature of the department and the limited access points for services. COMPONENTS OF THE UNIT 190.24.00 Introduction The Central Sterile Supply Unit will consist of a combination of Standard Components and Non-Standard Components. Standard Components must comply with details in Standard Components described in these Guidelines. Refer also to Standard Components Room Data Sheets. 190.25.00 190.26.00 190.27.00 Standard Components Provide the Standard Components as identified in the Schedule of Accommodation. Non-Standard Components Provide the Non-Standard Components as identified in this section and in the Schedule of Accommodation, according to the Operational Policy and Functional Brief. DECONTAMINATION DESCRIPTION AND FUNCTION The Decontamination area shall contains work space and equipment for sorting, decontamination and cleaning medical and surgical equipment, and for disposal of used/soiled material. It shall include hand-washing facilities. The Decontamination functions may also be provided in a Clean-Up Room. 190.28.00 190.29.00 There will be a need to provide special types of cleaning equipment, dependent on the level of service, for example, ultrasonic cleaners, anaesthetic tubing washers and dryers. LOCATION AND RELATIONSHIPS The Decontamination area should be located between the Receival area and the Sorting/ Packing area. 190.30.00 CONSIDERATIONS The Decontamination area will require the following finishes: - Walls and ceiling that are smooth, impervious, and easily cleanable - Floors that are impervious and non slip. Page 142 of 426

Fittings and fixtures located in this area will include the following: - Stainless steel deep bowl sinks with tubing manifolds (air and water) and additional water outlets for water pistols - Stainless steel benches - Instrument and tubing washers/ decontaminators, according to service requirements - Ultrasonic cleaner, according to service requirements - Instrument and tubing dryers, according to service requirements - Staff handwashing basin - Exhaust air extraction over sinks and equipment doors. All decontamination and washing equipment shall be installed and commissioned to the requirements of all relevant Australian Standards and Occupational Health requirements, in particular AS 2773 for Ultrasonic Cleaners and AS 2945, AS 3836 for Washer/Disinfectors. 190.31.00 STERILISING AND COOLING DESCRIPTION AND FUNCTION The Sterilising and Cooling Area provides accommodation for sterilisers and parking space for steriliser and cooling trolleys. Following unloading of the steriliser, packs should not be handled until cool. Specialised sterilisers such as ethylene oxide, require separate installation and accommodation. Low temperature specialised sterilisers require separate installation according to manufacturer's recommendations. The size of the area will be dependent on the number and type of sterilisers installed. 190.32.00 LOCATION AND RELATIONSHIPS The Sterilising and Cooling area should be located between the Sorting and Packing area and the Despatch area. Special consideration shall be given to the location of the sterilisers. External access to a steriliser duct is highly desirable so that repairs or routine maintenance do not interfere with the activities within the Workroom. A duct enclosure can also minimise heat build-up within the Workroom. An exhaust over the front of the steriliser(s) shall also be considered, to extract both heat (cabinet) and steam (opening door). 190.33.00 CONSIDERATIONS An exhaust over the front of the steriliser(s) shall be considered, to extract both heat (cabinet) and steam (opening door). Page 143 of 426

APPENDICES ROOM / SPACE 190.34.00 Standard Component CSSU Generic Schedule of Accommodation Schedule of Accommodation for a CSSU in a Hospital at levels 3, 4, 5 and 6: Level 3 Level 4 Level 5 Level 6 Remarks DEBOXING 1 x 15 1 x 15 1 x 15 DECONTAMINATION / -UP / WASHING DECONTAMINATION - RESPIRATORY DECONTAMINATION - SPECIAL INSTRUMENTS 1 x 15 1 x 40 1 x 80 1 x 80 May be smaller if Decontamination included in Clean-up Rooms 1 x 12 1 x 15 1 x 15 1 x 30 1 x 30 DISPATCH / TROLLEY HOLD 1 x 8 1 x 20 1 x 20 DISPOSAL ROOM yes 1 x 8 1 x 8 1 x 8 1 x 8 ENTRY/ INSTRUMENT RETURN 1 x 15 1 x 15 1 x 15 RESPIRATORY PACKING 1 x 20 1 x 20 SORTING & PACKING 1 x 12 1 x 30 1 x 50 1 x 50 STERILISING & COOLING 1 x 10 1 x 20 1 x 30 1 x 30 Area allows for 1 steriliser/plant for L3, up to 2 for L4 and up to 3 for L5/6 - NON- 1 x 6 1 x 20 1 x 30 1 x 30 - STOCK see remarks 1 x 6 1 x 20 1 x 30 1 x 30 Refer to Standard Component Store-Sterile; size according to quantity of stock CIRCUALTION % 20 20 20 20 ROOM / SPACE 190.35.00 Standard Component STAFF AREAS Note: Provision of Offices is dependent on the Operational Policy and Management Structure Level 3 Level 4 Level 5 Level 6 Remarks OFFICE - SINGLE PERSON 9 M2 yes 1 x 9 1 x 9 OFFICE - SINGLE PERSON 9 M2 yes 1 x 9 OFFICE - WORKSTATION yes 1 x 6 2 x 6 1 x 9 1 x 9 2 x 6 Manager ROOM / SPACE 190.36.00 Standard Component SHARED AREAS Level 3 Level 4 Level 5 Level 6 Remarks BAY - BEVERAGE yes 1 x 3 1 x 3 1 x 3 Page 144 of 426

ROOM - STAFF yes 2 x 8 2 x 10 2 x 10 May be shared with adjacent areas or Operating Unit ER'S ROOM yes 1 x 4 1 x 4 1 x 4 1 x 4 MEETING ROOM - LARGE yes 1 x 40 1 x 40 RECEPTION yes 1 x 10 1 x 10 STAFF ROOM yes 1 x 15 1 x 15 1 x 15 TOILET - STAFF yes 2 x 2 4 x 2 4 x 2 May be shared with adjacent areas or Operating Unit 190.37.00 References and Further Reading - American Institute of Architects, Guidelines for Design & Construction of Hospital & Healthcare Facilities, 1997. - Health Department Western Australia, Private Hospital Guidelines, 1998. - Queensland Government, Private Health Facilities Building Code, 2000. 190.38.00 Functional Relationships Diagram/s Refer to Enclosure Sheet 1 for a flow diagram representing the Base Model. 190.39.00 Refer to Enclosure Sheet 2 for a flow diagram representing a Stand-alone Model. 190.40.00 Refer to Enclosure Sheet 3 for a diagram showing the pressure differentials. 190.41.00 Refer to Enclosure Sheet 4 for a flow diagram indicating one sterile stock store. 190.42.00 Refer to Enclosure Sheet 5 for a flow diagram indicating two sterile stock stores. 190.43.00 Refer to Enclosure Sheet 6 for a flow diagram indicating a simple CSSU model which integrates (back to back) with an Operating Unit shown in Operating Unit Enclosure - Functional Relationship Diagram. Page 145 of 426

Enclosure FUNCTIONAL RELATIONSHIPS DIAGRAM - CENTRAL SUPPLY UNIT Sheet 1 of 6 STAND ALONE FLOW DIAGRAM WASTE DISPOSAL UTILITIES AND DISPOSALS EMERGENCY OPERATING SUITE DAY SURGERY WASTE DISPOSAL SOILED AREA CONTROLLED ENTRY AREA IN STAFF BARRIER AREA CONTROLLED ENTRY / AREA AREA (S & FOLDING) OUT

Enclosure FUNCTIONAL RELATIONSHIPS DIAGRAM - CENTRAL SUPPLY UNIT Sheet 2 of 6 SCHEMATIC FUNCTIONAL SPACE DIAGRAM (BASE MODEL) SERVICE ACCESS WASTE INSTRUMENT WASH/ UP ETHYLENE OXIDE (OPT) STERILIZER (AS REQUIRED) COOLING QUALITY CONTROL ISSUE OUTGOING TROLLEY PARK PASS THROUGH FEM SHWR WORKROOM LOADING TROLLEYS GENERAL PRE PACK & DISP STAFF ENTRY/ EXIT CORRIDOR FE ADMIN (OPT) VIEWS TO OUTSIDE (RECOMMENDED) LINEN FOLDING/ (OPTIONAL LOCATION WITH LAUNDRY) UNPACK & PRE PACK

Enclosure FUNCTIONAL RELATIONSHIPS DIAGRAM - CENTRAL SUPPLY UNIT Sheet 3 of 6 AIR FLOW DIAGRAM WITH PRESSURE DIFFERENTIALS SERVICE ACCESS STAFF ENTRY/ EXIT INSTRUMENT WASH/ UP TROLLEY PARK - - FEM CORRIDOR - - PASS N SHWR - ETHYLENE OXIDE - (OPT) THROUGH STERILIZER (AS REQ) WORKROOM N - COOLING LOADING TROLLEYS QUALITY CONTROL GENERAL N ++ ISSUE + PRE PACK & DISP ++ OUTGOING - - FE ADMIN (OPT) RELATIVE PRESSURE LEGEND N VIEWS TO OUTSIDE (RECOMMENDED) LINEN FOLDING/ (OPTIONAL LOCATION WITH LAUNDRY) - UNPACK - & PRE PACK ++ + N INCREASING RELATIVE PRESSURE - - - AIR FLOW DIRECTION

Enclosure FUNCTIONAL RELATIONSHIPS DIAGRAM - CENTRAL SUPPLY UNIT Sheet 4 of 6 SIMPLE MODEL 1 - INTEGRATED WITH OPERATING UNIT (ONE STOCK ) NOTE 1 DIRECT ACCESS (OTHER THAN PASS TRHOUGH) BETWEEN INSTRUMENT WASH AND THE WORKROOM SHOULD BE RESTRICTED OTHER THAN IN SMALL FACILITIES WHERE DUPLICATION OF STAFF FOR BOTH AND AREAS IS NOT POSSIBLE BARRIER ENTRY (SRUC - UP, GOWN, ETC PRIOR TO RE ENTRY) CORRIDOR WASTE INSTRUMENT WASH / UP DELIVERIES SPECIAL ITEMS STERILIZERS SEE NOTE 1 ETHYLENE OXIDE (OPTIONAL) QUALITY CONTROL COOLING / TROLLEYS OUTGOING OPERATING UNIT STAFF ENTRY/ EXIT UN STOCK LAUNDRY/ LINEN FOLD/ PACKAGING LINEN ADMIN STOCK SHOWER FE SHOWER STAFF LOUNGE (SHARED) REMOTE OR ATTACHED VIEWS TO OUTSIDE (RECOMMENDED) GENERAL CORRIDOR STAFF ENTRY / EXIT OUTGOING

Enclosure FUNCTIONAL RELATIONSHIPS DIAGRAM - CENTRAL SUPPLY UNIT Sheet 5 of 6 ALTERNATE MODEL 2 (TWO STOCK S) NOTE 1 DIRECT ACCESS (OTHER THAN PASS TRHOUGH) BETWEEN INSTRUMENT WASH AND THE WORKROOM SHOULD BE RESTRICTED OTHER THAN IN SMALL FACILITIES WHERE DUPLICATION OF STAFF FOR BOTH AND AREAS IS NOT POSSIBLE BARRIER ENTRY (SRUC - UP, GOWN, ETC PRIOR TO RE ENTRY) CORRIDOR WASTE INSTRUMENT WASH / UP STERILIZERS ETHYLENE OXIDE (OPTIONAL) QUALITY CON- OPERATING UNIT AND PRE-PACKAGED DELIVERIES SPECIAL ITEMS (OPTIONAL) UN STOCK SEE NOTE 1. WORKROOM COOLING / TROLLEYS OP. SUITE STOCK OUTGOING CORRIDOR LAUNDRY/ LINEN FOLD/ PACKAGING REMOVE OR ATTACHED LINEN ISSUE GENERAL STOCK ADMIN FE- SHR STAFF LOUNGE (SHARED) VIEWS TO OUTSIDE (RECOMMENDED) GENERAL CORRIDOR OUTGOING STAFF ENTRY/EXIT

Enclosure FUNCTIONAL RELATIONSHIPS DIAGRAM - CENTRAL SUPPLY UNIT Sheet 6 of 6 SUPPLY / SERVICE UNIT - SIMPLE MODEL Integrated with Operating Suite NOTE 1 NOTE 2 ONLY THE MOST IMPORTANT FUNCTIONS ARE SHOWN FOR CLARITY CSSU MAY BE CONNECTED TO OPERATING SUITE VIA / HOISTS CSSU TRANSFER LOBBY MAY BE REPLACED WITH HOIST LOBBY THEATRE DISPATCH AIR-LOCK MAY BE REPLACED WITH HOIST LOBBY SEMI-RESTRICTED ZONE RESTRICTED ZONE AIR LOCK NON - / LINEN CORRIDOR CH CH F M RESP PACK STOCK OFFICE(S) CORRIDOR TUTORIAL HOSPITAL CORRIDOR NON RESTICTED ZONE RECEIVING CSSD TROLLEY STRIPPING / ING / PARKING CSSU TRANSFER LOBBY FROM OPERATING SUITE UP/ INSTRUMENT WASHING TUNNEL WASHER ALTERNATIVE HOIST LOBBY CSSD PACKING & SORTING OPERATING UNIT PASS THRU STERILIZERS ALTERNATIVE HOIST LOBBY STERILIE/ COOL- ING AIR LOCK THEATRE DISPATCH TO OPERATING SUITE