LoH O Models LoH O Standard Features Uses 8 gallons (9. liters) of water per hour with sanitizing hot water rinse All tanks and hoods constructed from durable stainless steel with a No. finish and heliarced welded Stainless steel frame, legs and feet Two tank rackless conveyor shall have a maximum capacity of,09 dishes per hour at a belt speed of. (.0 M) feet per minute. At. feet (. M) per minute capacity will be 8, dishes per hour Belt width of 9 ( mm) and a maximum clearance of ( mm) throughout the machine Rear enclosure panels, hood and doors are stainless steel and double-wall insulated to reduce heat dissipation, outside surface temperatures, and noise pollution Insulated access doors for easy access, cleaning and servicing Sloped tank(s) design to increase visibility and accessibility for cleaning as well as ensure complete tank draining Heated power rinse zone uses fresh rinse water a second time to provide pristine results Exclusive Rainbow Rinse features an arched, removable upper rinse arm that provides superior rinse action while reducing water usage A sequential digital temperature readout of each tank housed in the door of the electrical control panel. The readouts will constantly display the temperature of the pre-wash, wash, power rinse and final rinse in second intervals A ball valve in the drain line of each tank and interconnected to a common machine drain connection at the load end of the machine Each tank will be automatically filled and maintained by a dual water level float. Water will be automatically added to the machine when required Block manifold wash arms are easy to remove, clean, and replace with nonclogging convex wash arm jet Large, removable scrap screens Pre-wash includes a deep-well removable scrap basket in addition to a large removable scrap screen Self draining stainless steel pumps, impellers, and housings are readily accessible and serviceable Service access from front of machine www.jacksonwws.com Project Item Quantity CSI Section 00 Approval Date Options Blower dryer Additional wash section Additional load module Additional unload module (8m) wash down hose - mounted Electrical connection with circuit breakers Dual point electrical connection Low profile doors Flanged feet Multiple conveyor peg choice Drain at load or unload end Prison Package Conveyor belt drive operates at two speeds and is protected by an overload safety device and an automatic shut-down actuator Each door is equipped with a safety switch. If a door is opened during operation the switch will immediately shut down the pumps and belt Operator activated start-stop switches on both the load and unload ends and the control panel Belt tension adjustment Removable insulated panels to enclose the unit down to the base frame on both the front and rear of the machine A single, built-in 8 square ( mm x mm) indirect vent connection with a 0.9 hp exhaust fan mounted in a cleanable cross duct on the machine for exhaust steam removal and indirect vent connection minimum wall clearance LoH O of 8
LoH O Electric '- " [mm] '- 8 " [8mm] '-" [mm] '-" [8mm] '- 8 " [mm] '- 8 " [mm] 9 " [mm] 9" [9mm] '- 8 " [8mm] '-0" [8mm] '- " [08mm] '- " [9mm] '- " [mm] " [mm] Minimum '- " [0mm] '- " [mm] '- " [9mm] " [mm] Minimum '- " [9mm] Control Cabinet Door Open ' [9mm] '-" [0mm] 8'-" [9mm] DIRECTION OF OPERATION Power Connections Inside Control Panel 8'-8" [mm] Doors In The Open Postion '-" [8mm] Optional - Short Doors In The Open Position '-" [8mm] 8 8 " [mm] " [mm] '- " [mm] '-0" [08mm] Top of Exhaust Fan Housing 9'-0" [mm] Maximum Ceiling Height for Short Doors - '-0" [88mm] '-" [8mm] '-" [mm] '- " [mm] 8 " [9mm] TYPICAL " [mm] 0 " [mm] 8" [mm] I.D. Square '-0" [08mm] A.F.F. " [mm] Deep Steam Vapor Exhaust Duct Minimum 8" Square (Cross Section Sq. In.) Provided by HVAC Contractor Exhaust Requirements - 00 CFM Condensate duct to extended into duct pan. Condensate duct pan mounted on top of dishmachine electrical section. Legend - " NPT Machine Drain Connection (Floor drain - optional to either end) - *Wash Tank Electrical Connection - *Rinse Tank Electrical Connection - *Booster Heater Electrical Connection - *Motor Controls Electrical Connection - /" NPT Incoming Water Connection - Vent Connection - See Detail *See Table For Amp Draw Note: The steam vapor removal system built into the dishmachine consists of a fan that will remove 00 CFM. A single steam vapor connection must be provided by the installing contractor. This is an indirect connection that must be capable of removing 00 CFM from the area. of 8 Visit us at www.jacksonwws.com or call us at -888-800-
'- " [mm] '-" [mm] '- 8 " [8mm] 9" [9mm] '- " [mm] '-" [8mm] '- 8 " [mm] '- 8 " [mm] '- 8 " [8mm] '- " [9mm] Control Cabinet Door Open '- " [9mm] '- " [0mm] " [mm] Minimum (Optional to drain at load or 9 " [mm] '- " [mm] '- " [9mm] '- " [08mm] '-0" [8mm] " [mm] Minimum unload end of the machine.) '-" [0mm] ' [9mm] 8'-" [9mm] DIRECTION OF OPERATION Power Connections Inside Control Panel '-0" [08mm] Top of Exhaust Fan Housing '- " [mm] '-" [8mm] '-" [8mm] Optional - Short Doors In The Open Position 8'-8" [mm] Doors In The Open Position 9'-0" [mm] Maximum Ceiling Height for Short Doors - '-0" [88mm] 0 " [mm] " [mm] 8 " [9mm] Typical '-" [8mm] '-" [mm] " [mm] 8 8 " [mm] '- " [mm] Jackson Electric Rackless Conveyor Wash, Power Rinse & Final Rinse Electrical requirements with booster* Heater kw Wash Heater & Pump Section Power Rinse Heater & Pump Section Pre-Wash Pump, Motors & Controls - Booster* 8 Totals *0 F rise booster 08V booster is.kw Pump HP 08V 0V 0V...8 00. 8.. Jackson Electric Rackless Conveyor with Blower Dryer Wash, Power Rinse & Final Rinse Electrical requirements with booster* Wash Heater & Pump Section Power Rinse Heater & Pump Section Heater kw. 0.. Pre-Wash Pump, Motors, Blower Dryer Heater & Controls 9.. 0.8 Booster* 8. 99. 00. Totals *0 F rise booster 08V booster is.kw JFT (electric) comes standard with -point electrical hookup. For other variations, please contact the factory. Pump HP 08V 0V 0V...8 00. 8... 9. 9.9.. 0.8. 8.. If water hardness exceeds grains, a water softener is required We reserve the right to change specifications appearing in this bulletin without incurring any obligation for equipment previously or subsequently sold. of 8
Load A start/stop switch is located at the load end of the machine for the operator s convenience. Load platform is gauge stainless steel. Pre-Wash Tank The pre-wash tank features a stainless steel manifold system with stricture-free jets to optimize pressure for soil removal and to provide easy access for removal and cleaning. A.0 hp, RPM motor and pump is horizontally mounted. The pump housing is stainless steel and self-draining. A stainless steel strainer with a removable basket is included. The pre-wash tank features a sloped design to ensure complete tank draining and to minimize soil build-up. Wash Tank The wash tank features a stainless steel manifold system with stricture-free jets to optimize pressure for soil removal and to provide easy access for removal and cleaning. A.0 hp, RPM motor and pump is horizontally mounted. The pump housing is stainless steel and self-draining. A stainless steel strainer with a removable basket is included. The pre-wash tank features a sloped design to ensure complete tank draining and to minimize soil build-up. Power Rin Stainless steel pow stricture-free jets m below the wares ar for cleaning. A.0 hp, R stainless steel housi included. Power ri sloped design to en draining and to min Machine Dimensions Load Pre-Wash Tank Wash Tank Power Ri Height Dep (9. mm) 8-/ (9 mm) (9. mm) (8 mm) (8 mm) (9 mm) (8 mm) (8 mm) (9 mm) (8 mm) (8 Shipping Dimensions Load/Unload (Shipped Together) Pre-Wash Tank Wash Tank Power Ri Height Dep (80 mm) (9 mm) ( mm) 9 (00 mm) (9 mm) ( mm) 9 (00 mm) (9 mm) ( mm) 9 (00 mm) 8 (9 Weight: lbs (8 kg) Weight: lbs (9 kg) Weight: lbs (9 kg) Weight: of 8
se Tank er rinse arms with ounted above and e easily removable PM motor with a ng and impeller are nse tank features a sure complete tank imize soil build-up. Final Rinse Rainbow Rinse features an arched, removable upper rinse arm that provides superior rinse action while reducing water usage. The final rinse water will cascade back to the power rinse, wash, then the pre-wash tanks. Blower Dryer A stainless steel tunnel incorporated into the discharge section of the machine. The blower dryer keeps the operating personnel from removing the wares before they reach the end of the unload section. An industrial fan-type with a squirrel cage driven by a 0. hp direct drive motor dries the wares as they exit the machine. *The Blower Dryer is an option and must be specified at time of order. Unload A start/stop switch is located at the unload end of the machine for the operator s convenience. Unload platform is gauge stainless steel. The drive wheel shaft is supported by two heavy-duty grease-lubricated ball bearings in pillow blocks. nse Tank Final Rinse Blower Dryer Unload th Length mm) (9 mm) 8 (08 mm) (8 mm) (9 mm) 88 ( mm) 8-/ (9 mm) (9 mm) (9 mm) 8-/ (9 mm) (0 mm) nse Tank Final Rinse Blower Dryer Unload th mm) Length ( mm) 88 ( mm) (9 mm) ( mm) 9 ( mm) (9 mm) ( mm) Shipped with Load End lbs (8 kg) Weight: lbs (88 kg) Weight: 0 lbs (9 kg) of 8
LoH O Steam '- " [mm] '-" [0mm] '-" [mm] '- " [80mm] 0'-8" [0mm] 8 " [mm] Minimum (Optional to drain at load or unload end of the machine.) '-8" [mm] '- 8 " [mm] '- 8 " [9mm] 9" [9mm] 0" [mm] '- 8 " [8mm] '-0" [8mm] '- " [08mm] '- " [9mm] '- 8 " [8mm] "[mm] Minimum '- " [mm] '- " [0mm] '- " [mm] '-0 8 " [90mm] '- " [9mm] '- " [9mm] Control Cabinet Door Open ' [9mm] ' [9mm] '-" [0mm] 8'-" [9mm] DIRECTION OF OPERATION 8'-8" [mm] Doors In The Open Position '-" [8mm] Optional - Short Doors In The Open Position '-" [8mm] 0" [mm] 8 8 " [mm] " [mm] PREWASH WASH POWER RINSE 8 CONTROL CABINET ' [9mm] '- " [mm] '-0" [08mm] Top of Condensate Duct Pan 9'-0" [mm] Maximum Ceiling Height for Short Doors - '-0" [88mm] '-8" [mm] 0'-8" [0mm] '- " [8mm] " [mm] 8 8 " [9mm] 0 " [mm] '- " [mm] '-" [mm] '-" [0mm] '- " [mm] 8" [mm] I.D. Square '-0" [08mm] A.F.F. " [mm] Deep Steam Vapor Exhaust Duct Minimum 8" Square (Cross Section Sq. In.) Provided by HVAC Contractor Exhaust Requirements - 00 CFM Condensate duct to extended into duct pan. Condensate duct pan mounted on top of dishmachine electrical section. Legend - " NPT Machine Drain Connection (Floor drain - optional to either end) - Electrical Connection - See Table for Amp Draw - /" NPT Incoming Water Connection - -/" NPT Steam Connection - /" NPT Wash Section Condensate Return - /" NPT Power Rinse Section Condensate Return - /" NPT Booster Heater Condensate Return 8 - Vent Connection - See Detail Note: The steam vapor removal system built into the dishmachine consists of a fan that will remove 00 CFM. A single steam vapor connection must be provided by the installing contractor. This is an indirect connection that must be capable of removing 00 CFM from the area. of 8 Visit us at www.jacksonwws.com or call us at -888-800-
'- " [mm] '-" [0mm] '-" [mm] '- " [mm] '- 8 " [8mm] 0" [mm] 9" [9mm] 8 '- " [80mm] 0'-8" [0mm] '-8" [mm] '- 8 " [mm] '- 8 " [9mm] '- 8 " [8mm] '- " [9mm] Control Cabinet Door Open '- " [9mm] '-0 8 " [90mm] '- " [0mm] '- " [mm] " [mm] Minimum 9 " [0mm] '- " [mm] '- " [9mm] '- " [08mm] '-0" [8mm] " [mm] Minimum '-" [0mm] ' [9mm] ' [9mm] 8'- 8 " [mm] DIRECTION OF OPERATION '-0" [08mm] Top Of Condensate Duct Pan '- " [mm] ' [9mm] 8 CONTROL CABINET POWER RINSE WASH PREWASH " [mm] 8 8 " [mm] 0" [mm] '-" [8mm] '-" [8mm] Optional - Short Doors In The Open Position 8'-8" [mm] Door In The Open Position 9'-0" [mm] Maximum Ceiling Height for Short Doors - '-0" [88mm] '- " [mm] 0 " [mm] 8 8 " [9mm] " [mm] '-8" [mm] 0'-8" [0mm] '- " [8mm] '-" [mm] '-" [0mm] '- " [mm] Jackson Steam Rackless Conveyor Wash, Power Rinse & Final Rinse Steam tank heat electrical requirements with booster Pump HP 08V 0V 0V Wash Section 8.9 8.. Power Rinse Section 8.9 8.. Pre-Wash/Drive/Exhaust. 0.. Totals 9..8. Jackson Steam Rackless Conveyor with Blower Dryer Wash, Power Rinse & Final Rinse Steam tank heat electrical requirements with booster Pump HP 08V 0V 0V Wash Section 8.9 8.. Power Rinse Section 8.9 8.. Pre-Wash/Drive/Exhaust/Blower Dryer 8..9 8. Totals... JFT (steam) comes standard with a -point electrical hookup. For other variations, please contact the factory. If water hardness exceeds grains, a water softener is required We reserve the right to change specifications appearing in this bulletin without incurring any obligation for equipment previously or subsequently sold. of 8
LoH O ELECTRICAL An electromechanical control system for increased reliability mounted in a stainlesssteel control cabinet on the front of the machine. A step-down transformer is included to provide volt, 0 cycles, phase operation for controls including solenoid valves, timers, etc. Wiring is 0C, 00-volt thermoplastic insulated wire and routed through UL approved conduit. Low watt density tubular heating elements are mounted inside the wash and power rinse tanks and are easily removable from the exterior of the unit. Heaters are protected by a water level float switch control and a high limit overload. Tank water temperature is maintained by a fast reacting thermostat which will control the heating element. STEAM Stainless steel tubular steam coils mounted inside the wash and power rinse tanks below the optimum water level and protected by a water level float switch control. An external Y strainer and high temperature steam solenoid to regulate the flow of steam through the coil. Tank temperature is controlled and maintained by a fast reacting thermostat that will control the operation of the steam solenoid. A float and thermostatic steam trap to remove the condensate from the coil are included. Steam coils will require a-0 PSI flowing steam pressure. BOOSTER HEATERS - ELECTRIC An internally mounted 8 kw electric booster heater sized to raise incoming 0 F ( C) water supply to 8 F (8 C) minimum for sanitizing rinse. The electric booster heater will have the capacity to heat 8 GPH from 0 F ( C) to 8 F (8 C) minimum. The tank is designed for a working pressure 0 PSI and hydrostatically tested at 00 PSI. The heater is complete with all plumbing, including NPT pipe and fittings from inlet and outlet. Electric heating elements are metal sheathed controlled by a close tolerance immersion thermostat. The booster is protected with a high temperature limit switch and low water cut-off. BOOSTER HEATERS - STEAM An internally mounted steam booster heater sized to raise incoming 0 F ( C) water supply to 8 F (8 C) minimum for sanitizing rinse. The steam booster heater will have the capacity to heat 8 GPH from 0 F ( C) to8 F (8 C) minimum. The tank is designed for a working pressure 0 PSI and hydrostatically tested at 00 PSI. The heater is complete with all plumbing, including NPT pipe and fittings necessary to meet all installation requirements. DIMENSION REQUIREMENTS Wall Clearance (Minimum) Inside Clearance (9 mm) H x 0 W ( mm x mm) STEAM REQUIREMENTS Steam Flow Pressure (PSIG) 0-0 Consumption @0 F Incoming Water Temp (Tanks only) 00 lbm/hr Consumption @0 F Incoming Water Temp (0 F Rise Booster) 8 lbm/hr OPERATING CAPACITY Consumption with blower dryer lbm/hr Dishes per Hour - Belt Speed. FPM (. MPM) 8, Dishes per Hour - Belt Speed. FPM (.0 MPM),09 OPERATING TEMPERATURES Pre-Wash (Recommended) 0 F (0 C) Wash (Minimum) F ( C) Rinse (Minimum) F ( C) Final Rinse 8 F (8 C) MOTORS Pre-Wash Pump Motor.0 hp Wash Pump Motor.0 hp Power Rinse Pump Motor.0 hp Conveyor Drive Motor / hp HOW TO SPECIFY: LoH O WATER REQUIREMENTS Inlet Tempterature 0 F ( C) Gallons per Hour 8 gal (9. L) Waterline Size IPS (Minimum-inches) / (9 mm) Drainline Size IPS (Minimum-Inches) ( mm) Flow Pressure (PSIG) TANK CAPACITY Pre-Wash Tank gal ( L) Wash Tank gal ( L) Power Rinse Tank gal ( L) PUMP CAPACITY Pre-Wash Pump 0 GPM (98 LPM) Wash Pump 0 GPM (98 LPM) Power Rinse Pump 0 GPM (98 LPM) 8 of 8 Jackson WWS, Inc. Shipping Address: 09 North U.S. Highway E, Gray, KY 0 Mailing Address: P.O. Box 00, Barbourville, KY 090 Telephone: 888-800- Fax: 0--99 Email: info@jacksonwws.com 00-00-9- [0//] www.jacksonwws.com We reserve the right to change specifications in this bulletin without incurring any obligation for equipment previously or subsequently sold.