ERV3015, ERV3615, ERV36-ER, ERV48, ERV48-ER, PRV30, PRV36, PRV48

Similar documents
ERV3015, ERV3615. Renaissance 30, 36 Wide, High Extension Slim Raised Vents. Top cap with vent down

RV30, RV36, RV46. 30, 36, 46 Wide, Raised Vent. Adjustable anchor legs. Front View

Downdraft Raised Vent

Integrated Ventilation System

Installation Instructions Remote Blowers

Installation Instructions. Millennia Island (Ceiling Mount) Range Hoods. Models: DHI361, DHI421, DHI482 and DHI542

Installation Instructions Preference Wall Mount Range Hood

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

Installation Instructions

VIPR Professional Downdraft w/remote

GE Monogram. Installation. Instructions. Component Cooktop System. Models ZEW145V ZGW124EN3 ZGW125EN3 ZEW155N ZEW166Y ZEW176Y

Installation Instructions

READ AND SAVE THESE INSTRUCTIONS

Cooktop Chimney Ventilation Hoods

CATTURA TM DOWNDRAFT MODELS D49M30SB, D49M36SB, D49M48SB

CAUTION signals a situation where minor injury or product damage may occur if you do not follow instructions.

READ AND SAVE THESE INSTRUCTIONS Page 1

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

Product Dimensions Page 1 of 7. DA Downdraft Ventilation Hood

L65369 Rev Planning Guide. Effective 04/13/15

ducted / recirculating separately 2.1 WS / 11.8 HS 3-stage Rear Yes (600 CFM options sold separately) 29 3/8" x 31" x 2 3/4" 6" or 8"

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

UseandCare & Installation Guide

Fits-More Capacity. Extra-large microwave provides 1.6 Cu. Ft. of cooking space and will hold almost any dish even a 13" x 9" baking dish.

Featuring Bake & Brown Convection Product Dimensions. Bake & Microwave Option

Fits-More Capacity. Extra-large microwave provides 1.6 Cu. Ft. of cooking space and will hold almost any dish even a 13" x 9" baking dish.

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

IMPORTANT SAFETY INSTRUCTIONS

Downdraft Ventilation

GAS COOKTOP INSTALLATION INSTRUCTIONS

MODELS D49M30SB, D49M36SB, D49M48SB DOWNDRAFT

Featuring Bake & Brown Convection Product Dimensions. Bake & Microwave Option

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

Over-the-Range Microwave Oven Installation Instructions MVH130* MVH230* MVH330*

gas cooktops EW30GC55P S / B

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

JP380BVBB - GE 30" Patio Grill with Downdraft Venting System

Installation Instructions Distinctive. Series Cooktop. Models DCT305, DCT365. Part No Rev. L

GE Appliances. Vent Systems. Downdraft. Owner s Manual JVB36 JVB66

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

Installation Instructions

Installation Instructions Preference. Cooktop. Models: SGM304, SGM365, SGM466. Part No Rev. K

SpaceWise Rack Our SpaceWise Rack creates more room so you can cook multiple dishes at once.

Questions on Installation? Call: GECARES (US) or Visit our Web site at: (US) 4" DUCT CLAMPS (2) OR 4" SPRING CLAMPS (2)

Installation Instructions

UCVM36RS 36-INCH DOWNDRAFT VENTILATION MASTERPIECE SERIES. GENERAL PROPERTIES Operating Mode Convertible: Ducted / Recirculating

UCVM30FS 30-INCH DOWNDRAFT VENTILATION MASTERPIECE SERIES

SpaceWise Rack Our SpaceWise Rack creates more room so you can cook multiple dishes at once.

Installation Instructions

READ AND SAVE THESE INSTRUCTIONS

Installation Instructions If you have questions, call 800-GE-CARES or visit our website at:

Viking Installation Guide

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

Over-the-Range Microwave professional series

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

High Power Range Hood

INSTALLATION INSTRUCTIONS

Mechanical Appliance and Equipment Inspection Checklist

Eve Ovens, Compactors, Room Air Conditioners, Dehumidifiers, Automatic Washers, Clothes Dryers, Freezers, Refrigerator-Freezers, Ice Makers,Oishwash

Installation Instructions

Installation. Professional Built-in Hoods

! INTENDED FOR DOMESTIC COOKING ONLY!

Over-the-Range Microwave

Glass Canopy Wall-Mount Hood

Installation Instructions

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Euro-style Range Hood ESH5200

INSTALLATION INSTRUCTIONS

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

Installation Instructions Epicure. Cooktop. Models: ESG366, ESG486. Part No Rev. K

Installation. Use & Care

COPPER INSERT INSTALLATION INSTRUCTIONS, USE AND CARE GUIDE

Dryer. User manual DV22K6800** DV22K A-00_EN (US)_ indd :15:41

Installation Instructions. Discovery Gas Cooktop. Models DYCT304G, DYCT365G. Part No Rev. A

SAFETY AND INSTALLATION MANUAL MODEL 8100

For use with models: PGM304-1, versions M-B PGM365-1, versions M-E, M-F & M-G

Installation Instructions

USE / INSTALLATION GUIDE

Features and specifications are subject to change at any time without notice. Throughout this guide, dimensions may vary by ± 3 mm.

Combination. IMPORTANT: Read and save. these instructions. Par-t No W / Rev. A

Questions on Installation? Call: 800.GE.CARES (US) WARNING RISK OF FIRE 4" DIA. METAL DUCT (RECOMMENDED) 4" DUCT CLAMPS (2) OR 4" SPRING CLAMPS (2)

HUMIDITY SENSING BATH FAN

VENT SYSTEM. USING THE HOOD Downdraft Vent System...5. CARE AND CLEANING Downdraft Vent System...6 INSTALLATION INSTRUCTIONS..7

MODULES. Features and specifications are subject to change at any time without notice. Throughout this guide, dimensions may vary by ± 3 mm.

36 Downdraft Hood Proud Mounting

CLe-series Dishwashers

Use, Care, and Installation Guide

APPUZO RANGE HOOD INSTALLATION

READ AND SAVE THESE INSTRUCTIONS

Installation Instructions Wall Ovens

RANGE HOODS RANGE HOOD INSTALLATION & OPERATIONS MANUAL

Questions on Installation? Call: 800.GE.CARES (US) WARNING RISK OF FIRE TOOLS YOU WILL NEED 4" DIA. METAL DUCT (RECOMMENDED)

Installation Instructions Use and Care Guide Instructions d installation Mode d emploi et d entretien

SAFETY INSTR[ WARNING WARNING. Read All Instructions Before Using the Appliance. READ AND SAVE THESE INSTRUCTIONS. Parts Needed.

EF36, IF36 PLANNING GUIDE. 36 Wide Built-In Refrigerator. (1.3 cm) 1/8. Opening Dimensions

UNDER CABINET RANGE HOOD

Microwave Oven Hood Combination

BUILT-IN MICROWAVE OVEN INSTALLATION INSTRUCTIONS 24" (61.0 cm), 27" (68.6 cm), 30" (76.2 cm)

VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS MODEL 50F / 70F / 70HS TABLE OF CONTENTS. Package Contents 2. General Safety Information 3

I NDUCTION C OOKTOP INSTALLATION INSTRUCTIONS

Transcription:

Document # PG08-001 Revised 02/28/14 Page 1/7 Dimensions - models ERV3015, ERV3615 5/16 (8 mm) thick stiffener across back 3 (7.6 cm) 1 15/16 (4.9 cm) 2 3/16 (5.6 cm) 2 1/8 (5.4 cm) 3/16 (5 mm) 2 9/16 (6.5 cm) Vent shown in raised position Renaissance Slim Chassis * Top cap with vent down 9/16 (1.4 cm) 15" (38.1 cm) * Total chassis depth with optional CP3 blower installed is 10 3/8 (26.3 cm). warning Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. This appliance must be installed in accordance with the accompanying installation instructions. ll tolerances: ±1/16 (±1.6 mm) unless otherwise stated 3/8 (1.0 cm) 2 1/8 (5.4 cm) Top cap - side view 20 (50.8 cm) 3 3/4 (9.5 cm) 1 1/8 (2.9 cm) 30 1/4 (76.8 cm) to 37 1/4 (94.6 cm) 30" 6 (15.2 cm) Motor cover Product data label 28" 3 prong grounded power cord djustable anchor legs Side View Front View Model No. ERV3015 ERV3615 30 36 (91.4 cm) 27 3/8 (69.5 cm) 33 3/8" 84.8 cm) ** Includes power supply requirements for blower Circuit Requirement** Three prong electrical outlet connected to 120 Vac, 60 Hz., 15 mp. grounded, dedicated, circuit NOTES: 1. Maximum installed height must not exceed the maximum specified countertop height of cooking appliance. 2. Install these downdraft vents only with approved Dacor appliances. See the planning guide for the particular appliance for proper applications and cutout information. 3. This appliance must be install in conjunction with a single, Dacor approved blower. See page 4/7 for approved blowers. 4. Local building codes may require the use of makeup air systems. Consult a qualified HVC specialist when designing the system for the requirements in your area and to assure optimal performance.

Document # PG08-001 Revised 02/28/14 Page 2/7 Dimensions - models ERV48, PRV30, prv36, PRV48 warning Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. This appliance must be installed in accordance with the accompanying installation instructions. ll tolerances: ±1/16 (±1.6 mm) unless otherwise stated 3/8" (1.0 cm) 2 1/8" (5.4 cm) ERV top cap - side view 7/16" (1.1 cm) 2 1/8" (5.4 cm) PRV top cap - side view Side View Front View Model No. PRV30 PRV36 PRV46 ERV48 30 36 (91.4 cm) 46 (116.8 cm) 48 (121.9 cm) 27 3/8 (69.5 cm) 33 3/8 84.8 cm) 43 3/8 (110.2 cm) 43 3/8 (110.2 cm) ** Includes power supply requirements for external blower Circuit Requirement** Three prong electrical outlet connected to 120 Vac, 60 Hz, 15 mp. grounded, dedicated, circuit NOTES: 1. Maximum installed height must not exceed the maximum specified countertop height of cooking appliance. 2. Install these downdraft vents only with approved Dacor appliances. See the planning guide for the particular appliance for proper applications and cutout information. 3. This appliance must be install in conjunction with a single Dacor approved blower. See page 4/7 for approved blowers. 4. Local building codes may require the use of makeup air systems. Consult a qualified HVC specialist when designing the system for the requirements in your area and to assure optimal performance.

Document # PG08-001 Revised 02/28/14 Page 3/7 Dimensions - models ERV36-er, ERV48-er 5/16 (8 mm) thick stiffener across back 2 1/2" (6.4 cm) 1 15/16" (4.9 cm) 1/4" (6 mm) 2 9/16" (6.5 cm) 2 13/16" (7.1 cm) Top cap with vent down warning Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. This appliance must be installed in accordance with the accompanying installation instructions. ll tolerances: +/- 1/16 (+/- 1.6 mm) unless otherwise stated Model Number ERV36-ER 36 (91.4 cm) 33 3/8 (84.8 cm) ERV48-ER 48 (121.9 cm) 43 3/8 (110.2 cm) NOTE: See the appliance planning guide page for cutout dimensions Vent shown in raised position 10" (25.4 cm) 18 5/8 (47.3 cm) 3 3/4" (9.5 cm) 1" (2.5 cm) 30 ¼" (76.8 cm) to 37 ¼" (94.6 cm) 30" 6" (15.2 cm) Motor cover Product data label 28" 3 prong grounded power cord djustable anchor legs NOTES: 1. Maximum installed height must not exceed the maximum specified countertop height of cooking appliance. 2. Install these downdraft vents only with approved Dacor appliances. See the planning guide for the particular appliance for proper applications and cutout information. 3. This appliance must be install in conjunction with a single Dacor approved blower. See page 4/7 for approved blowers. 4. Local building codes may require the use of makeup air systems. Consult a qualified HVC specialist when designing the system for the requirements in your area and to assure optimal performance. Circuit Requirement (all models)* Three prong electrical outlet connected to 120 Vac, 60 Hz, 15 mp. grounded, dedicated, circuit * Includes power supply requirements for external blower.

Document # PG08-001 Revised 02/28/14 Page 4/7 Duct System Layouts and pproved lowers IMPORTNT: Do not install more than one blower with this appliance. acksplash PPROVED DCOR LOWERS lower Model lower Rating Compatible with CP3 1 600 CFM 2 ERV3015 3, ERV3615 3 ILHSF8 600 CFM 2 ll Dacor ERV, PRV Series Models Cooktop ILHSF10 1100 CFM 2 ll Dacor ERV, PRV Series Models REMP3 600 CFM 2 ll Dacor ERV, PRV Series Models REMP16 1000 CFM 2 ll Dacor ERV, PRV Series Models 1 IMPORTNT: Due to a lack of clearance, do not use a CP3 blower if a range or wall oven is to be installed in front of the downdraft vent. 2 Nominal rating at zero inches static pressure, see the blower panning guide page for actual blower ratings. 3 Revision and later units only. Installation of blower model CP3 requires Dacor adapter kit # ERVC. Cabinet blower, option on ERV3015 and ERV3615 only Wall The CP3 blower assembly is mounted to the front of the downdraft vent with the exhaust pointing in the desired direction. With ILHSF and REMP blowers, the downdraft vent can be configured to exhaust through the back, the bottom or either side by removing the appropriate exhaust knock-out. Floor 3 1/4 x 10 90 elbow Wall cap See the following pages for duct layout requirements and maximum duct length. REMP series remote blower 12 min. (30.5 cm) 3 ¼ x 10 to round transition and 45 adjustable elbow Example of Layout with cabinet lower configuration, Exhaust Through Wall Wall board Duct work between downdraft and remote blower acksplash Cabinet back Outside wall Cooktop configured for rear exhaust Range configured for bottom exhaust 3 ¼ x 10 to round transition Floor Wall cap on outside wall Floor Wiring/conduit from downdraft to remote blower Wiring/conduit from downdraft to in-line blower Duct work Duct work ILHSF series in-line blower Example of Layout with Cooktop and Rear Exhaust Example of Layout with Range and ottom Exhaust

Document # PG08-001 Revised 02/28/14 Page 5/7 Electrical Layout ll tolerances: ±1/16 (±1.6 mm) unless otherwise stated Exhaust outlet location options side view front view Cabinet blower - option on ERV3015, and ERV3615 only Connection to cabinet blower lower wiring access hole 1 1/8 (2.9 cm) 6 1/2 (16.5 cm) Motor cover 26" (66.0 cm) Connection to remote/in-line blower lower wiring access hole There are 7/8 access holes in the bottom and side of the downdraft vent for connecting the blower wiring and strain relief. The blower must be wired to turn on when the downdraft vent is turned on. When installing a remote or in-line blower, run the blower wiring/conduit parallel to the duct work, connecting it to the downdraft vent on one end and the blower on the other. ccess from the front of the cabinet to the chassis and the electrical/ gas supplies of both appliances must be provided for inspection and service. ny drawers or shelves must be easy to remove for access to the cooktop, downdraft vent and utilities. Rear Exhaust Knock Out (3 ¼ X 10 ) Vertical of rear exhaust knock out lines up with vertical of chassis ottom Exhaust Knock Out (1 ⅝ X 16 ) The vertical of bottom knock out is offset 3 Side Exhaust Knock Outs (1 ⅝ X 16 ) 5" (12.7 cm) 3 2 x 16, connects to side or bottom exhaust on downdraft 1" (2.5 cm) 3 ¼ x 10 to duct work 2 x 16 to 3 1/4 x 10 transition (included)

Document # PG08-001 Revised 02/28/14 Page 6/7 CP3 lower Layout (option ERV3015 and ERV3615 only) ERV Cooktop Model C ERV3015 ERV3615 12 1/8 (30.7 cm) 9 3/4 (24.8 cm) 5 5/8 (14.4 cm) 8 (20.3 cm) 1 3/4 (4.4 cm) 4 1/4 (10.8 cm) CP3 Countertop DPTER 8 7/8" (22.5 cm) from back of ERV cutout to center line of CP3 exhaust in any orientation ottom exhaust configuration shown 26 1/4 (66.7 cm) 3 1 /4 x 10 duct connection DUCT Duct connection Exhaust Locations and Side Dimensions for CP3 Cabinet blower Front Exhaust Dimensions CP3 lower - Left Exhaust Countertop Countertop Duct connection C 15 3/8 (39.1 cm) 3 1 /4 x 10 duct connection Duct connection 29 1/4 (74.3 cm) 3 1 /4 x 10 duct connection Front Exhaust Dimensions CP3 lower - Right Exhaust Front Exhaust Dimensions CP3 lower - ottom Exhaust

Document # PG08-001 Revised 02/28/14 Page 7/7 Duct Work Design Considerations For optimal performance, consult a qualified HVC specialist when designing the duct system. ll duct work materials (including screws and duct tape) must be purchased separately by the customer. Cross-drafts or air currents from adjacent open windows or doors, heating/air conditioning outlets, ceiling fans and recessed ceiling lights reduce vent efficiency. When planning the cabinet layout, allow room for the exhaust duct coming out of the unit. lways look for the shortest, most direct route to the outside. Do not use flexible metal duct. Wherever possible, reduce the number of transitions and turns to as few sharp angles as possible. Two staggered 45 angles are better than one 90. Keep turns as far away from the hood exhaust as possible, with as much space between each bend as possible. For best performance, use round duct instead of rectangular when possible, especially when elbows are required. If multiple elbows are used, try to keep a minimum of 24 of straight duct between them. void S or back to back configurations of adjacent elbows. You can increase the duct size over the duct run if desired. To prevent a back draft, never decrease the duct size over the run. To prevent back-drafts, a damper at the duct outlet may also be required. Make sure duct work does not interfere with floor joists or wall studs. System exhaust location must take into account accumulated snowfall, where applicable. Calculating the Maximum Duct Run Length Do not use duct work that is smaller in cross-sectional area than the required duct sizes in the lower Maximum Duct Straight Length table below. For best performance, keep the duct run as short as possible and never exceed the maximums stated. The maximum straight duct length for the downdraft vent system depends on the model of remote or in-line blower used with the vent system and the number of elbows and transitions used. The Equivalent Number of Feet for each elbow and transition must be subtracted from the maximum straight length to compensate for wind resistance. To determine the maximum allowable length of the duct work, subtract all of the equivalent lengths of the elbows and transitions from the lower Maximum Duct Straight Length. For example, for a downdraft vent system using 3 ¼ X 10 rectangular duct, two (2) 3 ¼ X 10 90 elbows, a 3 ¼ X 10 rectangular to 10 round transition, and a REMP16 remote blower: From the lower Maximum Duct Straight Length table, the maximum length without transitions and elbows is. The equivalent length of each 90 elbow is 15 feet. The equivalent length of 45 elbow is 2 feet. The equivalent length of the transition is 4 feet. The total equivalent length of the above components is: 15 feet + 15 feet + 4 feet + 2 feet = 36 feet. The maximum amount of straight duct that can be used with a REMP16 and the above components is: - 34 feet = 24 feet. Equivalent Number of Feet - Duct Elbows and Transitions 45 elbow, 8 inch 3 feet 3 ¼ X 10, 45 elbow 7 feet 45 elbow, 10 inch 2 feet 3 ¼ X 10, 90 elbow 15 feet 90 elbow, 8 inch 7 feet 3 ¼ X 10, 90 flat elbow 20 feet 90 elbow, 10 inch 5 feet 3 ¼ X 10 to 8 round transition 4 feet 90 3 ¼ X 10 to 8 round transition 25 feet 3 ¼ X 10 to 10 round transition 4 feet Roof cap * Wall cap** * * The equivalent lengths of roof and wall caps vary with model and configuration. For equivalent length, contact the manufacturer or a qualified HVC specialist. ** Not applicable for REMP series blowers. Duct Size Used REMP3 Remote lower 50 feet (15.2 meters) lower Maximum Duct Straight Length REMP16 Remote lower ILHSF8 In-line lower 50 feet (15.2 meters) ILHSF10 In-line lower 70 feet (21.3 meters) CP3 Cabinet lower 30 feet (9.2 meters) 30 feet (9.2 meters) 8 Inch 70 feet (21.3 meters) 10 Inch 3 ¼ X 10