THE ULTIMATE ROOFTOP SOLUTION

Similar documents
All Chiller Products. Water Cooled and Air Cooled Modular Chillers Available in 208, 230, 460 & 575 Volts Application Ranges from 30 to 1,000 Tons

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

The ultimate fresh air solution.

Cultivator & Hybrid Cultivator

Bring the fresh in. D E D I C A T E D O U T S I D E A I R S Y S T E M

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

Maverick II Commercial Rooftop Systems 15 to 75 tons

SHConDEMAND. True Redundancy. Heating. Cooling. Simultaneous. Efficient. Reliable

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

ALL PRODUCTS BROCHURE

RT-OA TM Rooftop Outdoor-Air (DOAS)

RoofPak Applied Rooftop Systems

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:

Energy Recovery with Cooling and Heating Model ERCH

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:

Heat Pumps M2 SERIES. Modular Self-Contained Unit Water-Source Heat Pumps (3-70 tons) Features:

Energy Recovery with Cooling and Heating

CB/CF. Series CONDENSERS AND CONDENSING UNITS. Features:

62DA,DB,DC,DD,DE,DF07-38

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

DX Units. Ranging from 15 to 750 tons and 1,000 to 300,000+ CFM

PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION

Commercial Packaged Rooftop Systems

THE RIGHT SPEC. RIGHT NOW.

CONDENSERS AND CONDENSING UNITS

Flexible & Innovative. Cooling Solutions

PRODUCT SERIES. VPR Series VPRX Series VPRE Series VPRP Series VPRC Series

Series. Chillers and. Features: Application Flexibility Minimizes Installation Time and Reduces Cost

EP SERIES PACKAGED ENERGY RECOVERY SYSTEM ENERGY EFFICIENT AIR COMFORT

Economical, Flexible, Advanced Performance. Ventilation and Dehumidification for Healthy IAQ

From 230 tons to. Water-Source Heat Pump Products. Premium Performance Environmentally Friendly Superior Construction

SECTION (15733) - DEDICATED OUTDOOR AIR UNITS

Tulsa, OK Longview, TX

Direct Gas-Fired Make-Up Air Models DG and DGX

Product Data. Features/Benefits. 62DA,DB,DC,DD07-38 Dedicated Vertical or Horizontal Outdoor Air Unit with Optional Energy Wheel. 6 to 35 Nominal Tons

AHU ENERGY RECOVERY VENTILATORS ERV DEDICATED OUTDOOR AIR SYSTEMS DOAS HEATING, COOLING & DEHUMIDIFICATION AHU

XeteX, Inc. All Rights Reserved.

Product Data. Features/Benefits. 62DA,DB,DC,DD,DE,DF07-38 Dedicated Vertical or Horizontal Outdoor Air Unit with Optional Energy Wheel

VariCool VAV Engineering Guide

EP Model. EP Model Water Source Heat Pump. ½ to 6 Ton

Modular Supply Make-Up Air Unit

Control Systems. Design & Manufacturing. Eco-Friendly. High Performance

Mammoth Water Source Heat Pumps

DOAS UNITS. ReznorHVAC.com MAKEUP AND VENTILATION AIR 100% OUTSIDE AIR

PACKAGED HVAC EQUIPMENT CATALOG

Mission Critical. Series 6, 8 & 9. vertical floor mount Ton Units. Air Conditioning Systems

PoolPak MPK Series. PoolPak.com. Environmental Control Systems REDUCED FOOTPRINT & WEIGHT COMPARED TO EARLIER GENERATIONS

TYPICAL CPA SPECIFICATIONS

STEP INSIDE FOR A BREATH OF FRESH AIR. Designed to provide significant outdoor ventilation air to any space.

Trane Performance Climate Changer Air Handlers. An air handler for every need.

Heat Recovery Ventilator Model PVe Light Industrial Commercial Institutional

VH Series B ENVIRO-STAC Vertical Hi-Rise Fan Coil Unit with Enhanced Humidity Control

Product Data. Features/Benefits. 62DA,DB,DC,DD,DE,DF07-38 Dedicated Vertical or Horizontal Outdoor Air Unit with Optional Energy Wheel

SECTION (15733) - DEDICATED OUTDOOR AIR UNITS

Energy-Efficient Makeup Air Units BY HUGH CROWTHER, P.ENG., MEMBER ASHRAE

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

Direct Gas-Fired Make-Up Air Models DGK, DG and DGX

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

MAXA-MI$ER Energy recovery solutions

RT-OA TM Rooftop Outdoor-Air (DOAS)

Addendum Downsville Pike Hagerstown MD April 29, 2016

Data Aire LCS TM (Large Ceiling System) R-410A. 6, 8, 10, and 13 ton. ISO 9001 Certified

COMMERCIAL HVAC PACKAGED EQUIPMENT. Rooftop Units Level 1: Constant Volume

DSC Series. Submittal Data Form. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h

DES CHAMPS PRODUCTS. Specializing in: -- Air-to-Air Energy Recovery -- Conditioning Outdoor Air -- Controlling IAQ -- Indirect Evaporative Cooling

Trane Performance Climate Changer Air Handlers. An air handler for every need.

VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU Ton Water-Cooled

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS - CUSTOM

RTU. Roof Top Units 8 30 Ton. Maxi-Kool.

sm All Product Catalog

Guide Specifications for InRow Direct Expansion

Performance and rugged durability. Commercial Split Systems Up to 20-Ton TSA/TPA Models

Submittal Summary Page

T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

BOOK 2 SPECIFICATIONS

Product Data. 75 to 150 Nominal Tons

Manufacturer Update 2014 IGSHPA

Modular Heating & Ventilating Unit Model IGX-HV

E-Series Rooftop Units 60 HZ

Best Practices for Applied Rooftop ` Systems, Applications and. Jerry Cohen President Jacco & Assoc. Installation

Technical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer

Vision and Skyline Semi-custom Air Handlers

DES CHAMPS PRODUCTS 85% 4,400 CFM

Best Practices for Applied Rooftop ` Systems - Application and. Jerry Cohen President Jacco & Assoc. Installation

Multi-Path RTU-TYPE 2

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

Reinventing Energy Efficiency

Air Handling Units. Ranging from 15 to 2,000+ tons and 500 to 400,000+ CFM

Innovent s. Direct Replacement Program. Engineered to match... your footprint, your needs.

Catalog Rebel Commercial Packaged Rooftop Systems

CHILLED WATER DATA ROOM UNITS

Transcription:

Configured Packaged Rooftop Solutions Specializing in Dedicated Outdoor Air Systems (DOAS) Capacities from 6 to 90 Tons Available in 208, 230, 460 and 575 Volts THE ULTIMATE ROOFTOP SOLUTION

Service Friendly Ultimate Efficiency Design Flexibility

Features & Benefits Flexible Yet Affordable Design Platform Allows numerous applications such as Air Cooled Cooling, Air Cooled Heat Pump, Water Source Heat Pump, Geothermal Heat Pump and Chilled Water Air Handler. Provides near infinite Green solutions for filtration, heat recovery, exhaust and return air, supply air, heating, make-up air and controls. Specializing in Dedicated Outdoor Air Systems (DOAS) Optimized refrigerant management with 6-row, face split, DX coil ensures ideal dehumidification at all ambient conditions. Designed for compliance with ASHRAE 62.1 standards. For mold prevention, systems and controls designed to limit space relative humidity to 60% or less during all load conditions. Lower Utility Costs Ultimate efficiency, exceeding ASHRAE 90.1 standards, obtained through high efficiency scroll compressors, optimized heat transfer, variable speed condenser fans with EC motors and modulating control. Energy saving 2 double wall cabinet with injected polyurethane foam provides R-13 insulation value. Reduce Service & Maintenance Costs Innovative and simplistic design with hinged access doors to generously sized control and access compartments. Quality components include slide out IAQ double sloped stainless steel drain pan, variable speed EC condenser fans with integral head pressure control, direct drive backward curved plenum supply fans with VFD controls and 2 MERV 8 pleated filter as standard features. Endless Control Strategies Fully integrated DDC controls provide open protocol for BACnet, LonWorks, Modbus and N2. Optional factory mounting and wiring of customer furnished controls. Potential LEED Credits: Construction IAQ Management Plan During Construction Filtration media with minimum efficiency reporting value (MERV) of 8. Enhanced Commissioning Onsite maintenance and operational training provided by certified representative. Increased Ventilation Heat-recovery ventilation and/or economizer strategies to improve indoor air quality promoting occupancy comfort, well-being and productivity. Optimized Energy Performance Exceeds ASHRAE 90.1 minimum efficiency standards. Outdoor Air Delivery Monitoring Supply and exhaust airflow monitoring controls for precise airflow verification. Thermal Comfort Controllability of Systems, Design & Verification Controllability of systems for precise required heating and cooling to ensure highest comfort for building occupants. Equipment designed specifically for 100% outdoor air application. Application Flexibility Air Cooled Cooling Air Cooled Heat Pump Water Source Heat Pump Geothermal Heat Pump Chilled Water Air Handler

The Ultimate Rooftop Solution Reliability Dual R-410A scroll compressors and independent refrigeration circuits for superior efficiency, proven reliability and quiet operation. Standard ambient operating range of 0-115 F. 6-row, face split, 12 fpi, DX coil for superior latent heat removal at all operating conditions. High efficiency, variable speed EC condenser fans with integral head pressure control, acoustical design providing low operating noise levels. Slide out double sloped insulated stainless steel IAQ compliant drain pan. Filtration Standard 2 MERV 8 pleated filters, per ANSI/ ASHRAE Standard 52.2. Optional MERV 13, 14 pleated filters. Cabinet Construction 2 double wall construction with injected polyurethane foam insulated panels for all doors, roof, walls and floor. R-13 insulation with thermal break minimizes heat transfer through the cabinet and provides moisture barrier and improved indoor air quality. Heavy gauge G90 galvanized steel with 3 mil powder coat paint finish. Sloped roof to eliminate standing water. Access doors with friction hinges and quarter turn handles with roller cam for easy access and serviceability. Continuous bulb gasket around access doors

Control Options Integrated DDC controls provide advance algorithms for maintaining precise temperature and comfort control. BAS interface with BACnet, LonWorks, Modbus and N2 communications. Optional terminal strip mounting and wiring of customer supplied controls. Verifiable Performance AMCA certified direct drive blower motor and plenum supply fan assembly with factory installed spring isolators eliminating resonance conditions within operating range. Factory provided integral Variable Frequency Drive offering flexible operating points in response to changes in pressure, flow or other external data. Outdoor air inlet hood with mist eliminator filter. Built in airflow measurement device. High performance, two-position motorized outdoor air dampers. Extruded aluminum with airfoil blades and jamb seals allows low pressure drop and less noise generation. Compliant with ASHRAE 90.1 low leakage requirements. Quiet airfoil wheel eliminates additional cost for acoustical attenuation. Engineered rooftop solutions with industry leading energy efficiency, design flexibility, serviceability and treating outside air.

Options for Every Application Energy Conservation Wheel (ECW) Hard core molecular sieve desiccant with galvanized steel frame. Slide out conveyor system for ease of maintenance. Improves Indoor Air Quality (IAQ). Provides maximum energy efficiency and minimizes operating costs. Transfers latent and sensible energy. Optional oversized wheel for higher efficiency and lower air pressure drop. Defrost control, pulse or variable speed. Certified performance per AHRI 1060. Refrigeration & De-Humidification Variable capacity scroll compressors. Hot gas bypass. Modulating hot gas reheat coils. Liquid sub-cooling coils - constant or switchable. Compressor isolation valves. Factory installed refrigerant to air energy recovery device. Electrical 115 V convenience outlet field or factory wired. Service lights for maintenance convenience. Firestat and smoke detector terminal. Main disconnect. Fully Modulating Heat Gas Heat - Stainless steel 409 and 304 full heat modulation for precise temperature control. Oversized furnaces available to handle up to 80 or 90 F design temperature rise. Electric heat with modulating control, open or finned tubular element. Hot water coil. Steam distributing coil. Miscellaneous Harsh environment condenser coil coating. Harsh environment evaporator coil coating with stainless steel coil casing. Condensing coil guard or hail guard. Roof curbs - 14 or 24. Common Market Applications Education Healthcare Athletic Facility

Treasure on the Bay North Bay Village, FL Hofbrauhaus Cleveland, OH Norcross Cluster Elementary Norcross, GA Briarwood Elementary Moore, OK Pine Haven Christian Communities Sheboygan Falls, WI

106 L x 100 W x 65 H Air Cooled & Water Cooled Data Air/Water Cooled, Air/Water Source Heat Pumps and Geothermal Standard Cabinet 2 Series 4 Series 8 Series 6 7.5 10 12.5 750-8,000 15 15 17.5-20 140 L x 20 1,500-100 W x 25 13,500 90 H 30 287 L x 31 35 100 W x - 40 102 H 338 L x 100 W x 102 H 41 50 60 70 80 90 3,750-28,000 171 L x 100 W x 65 H Including Energy Conservation Wheel & Powered Exhaust 2 Series 4 Series 8 Series 6 7.5 10 12.5 1,000-15 8,000 15 17.5-20 212 L x 20 3,500-100 W x 25 13,500 90 H 30 377 L x 31 35 100 W x - 40 102 H 428 L x 100 W x 102 H 41 50 60 70 80 90 Note: Maximum design CFM may be larger depending on conditions selected for unit. 7,000-24,000 Contact your local ClimaCool representative or visit our web site at www.climacoolcorp.com to find out more about other heating and cooling solutions that may fit your application needs. 15 S. Virginia Oklahoma City, OK 73106 Phone: 405.815.3000 Fax: 405.815.3052 www.climacoolcorp.com ClimaCool works continually to improve its products. As a result, the design and specifications of each product at the time for order may be changed without notice and may not be as described herein. Please contact ClimaCool s Customer Service Department at 405.815.3000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimaCool s opinion or commendation of its products. USGBC and related logo is a trademark owned by the U.S. Green Building Council and is used with permission. Doc #: MUA Brochure ClimaCool Corp. 2017 3/18