SZ-PIR04N ZigBee Motion Detector Installation Guide

Similar documents
ADT. Pulse 2017ADT LLC

Atomic Digital Office Clock

QUICK START GUIDE. Lono, LLC 686 East 110 South, Suite 102 American Fork, UT 84003

Intelligent Home Solutions Quick Start Guide. Monitor your home from anywhere with your smartphone

Wi-Fi DOOR/WINDOW SENSOR

XHS1-TY / MP-841 ZigBee Home Automation 1.2 Wireless Digital Pet Immune PIR Detector

NXSMP-LMI LOW MOUNT INDOOR SENSOR MODULE

PET IMMUNE PIR MOTION DETECTOR

2 x screws. 2 x wall plugs

Optima ZigBee Thermostat

Wireless Outdoor Air Reset Adaptor PN:

1100D Wireless Receiver

Wireless Weather Station

Smart Hub THERMOSTAT. Installation Manual

1100X Wireless Receivers

Pet Immune SAW PIR Motion Sensor

Low Voltage Fan Coil Thermostat ST101ZB. Quick Start Guide. For other language versions, please visit

Embedded Door Sensor. User's Manual. Model SS881ZB. For other language versions, please visit:

TP WEM01 A Carrierr Côr Thermostat AC/HP Wi-Fir Thermostat Performance Series. Installation Guide

Draft - develop and review

Features and content. This is where air comes into your detector.

OPERATION MANUAL WARNING TO REDUCE THE RISK OF INJURY OR PRODUCT DAMAGE, READ OPERATION MANUAL PRIOR TO OPERATING PRODUCT.

Smart THERMOSTAT. Installation Manual

ShockLink. Important Product Information.

Smart Radon Detector with Indoor Air Quality Sensors

Caught a critter in the act?

Smart Radon Detector with Indoor Air Quality Sensors Version 1, May 8, 2018

Model:T83646v2 Quick Setup Guide DC: WIRELESS WEATHER STATION

Automatic Dimming Mirror with HomeLink

Wireless External Alarm

Yale Real Living Push Button Deadbolt Installation and Programming Instructions (YRD210)

Rev D 3/20/17

Yale Real Living Push Button Lever Installation and Programming Instructions (YRL210)

EL-TSTAT Owner s Manual

Evolve 5.5 cu. ft. Medical-grade Undercounter Refrigerator

SkyNEST WASP Portable Kit, Smart Receiver and SCADA Gateway with Solar Panel USER MANUAL

Yale Real Living Key Free Touchscreen Deadbolt Installation and Programming Instructions (YRD240)

Yale Real Living Touchscreen Deadbolt Installation and Programming Instructions (YRD220)

Technical support is also available by or by phone: (North America) (International)

Yale Real Living Touchscreen Lever Installation and Programming Instructions (YRL220)

DT8050A DUAL TEC Motion Sensor with Anti-Mask - Installation Instructions

GARAGE DOOR OPENER KIT

Impassa CDMA Module INSTALLATION GUIDE

1 Copyright 2015 Alarm.com. All rights reserved. Rev 3.4

Yale Assure Lock Push Button Deadbolt Installation and Programming Instructions ( YRD216/YRD416)

EN1221S-60 Waterproof Pendant Installation and Operation Manual

1 Copyright 2014 Alarm.com. All rights reserved. Rev 3.3

How to install your ecobee4

Contents. User Manual GA-U-1. VultureNet: Long Range System

S541.RF 4G Product Guide

ecobee 3 Quick Start Guide Installation Guide DRAFT

Yale Real Living Key Free Push Button Deadbolt B1 with Installation and Programming Instructions

Touchscreen Comfort Control

Save these instructions This product is for household only

1125 PIR Motion Detector

Yale Assure Lock Push Button Deadbolt Installation and Programming Instructions ( YRD216/YRD416)

InTemp CX Temperature Logger (CX40x) Manual

Installation Guide. Model TBZ48A Battery Powered Z-Wave Thermostat. This thermostat is compatible with most HVAC systems, including the following:

Yale Real Living Assure Lock Push Button Deadbolt Installation and Programming Instructions (YRD216)

Home Comfort Control with Wi-Fi Model 8910W READ AND SAVE THESE INSTRUCTIONS. Owner s Manual. Includes Operating Instructions and Warranty Information

1126 Series Ceiling Mount PIR Motion Detector

XL200L/600L/700L GPRS Control Panel

Smoke Bridge Owner s Manual

ADC-T2000. Smart Thermostat v1.5

Nest x Yale Lock Programming/Troubleshooting Guide

EcoView Thermostat. Product Description. Installation. Product Number. Caution Notations. Required Tools. Expected Installation Time.

THB4002. GoTemp Food Infrared Thermometer With Laser Sighting And Thermocouple Jack User Guide. Measuring Temperature The Smart Way.

Water Sensor. Model CFWS10

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

INTRODUCTION. Industry Canada: Canadian ID: 6982A-YRHCPZW0 (Z-Wave); 6982A-YRHCPZB0 (Zigbee)

XTO-IP ALARM PANEL. Description. Supervised Wireless Technology. Features

OPTIMA ZigBee Thermostat

Installer Guide smart connect

W8735ER Wireless Outdoor Reset Module

EN1221S-60 Waterproof Pendant Installation and Operation Manual

Intelli-Time Alarm Clock model 13041RM

Yale Real Living Key Free Push Button Deadbolt B1L Installation and Programming Instructions

DOWNLOAD THE BILT APP. x3 #8-32 x 5/16" Machine screws. x4 #7 wood & #8-32 machine x 20mm Combination screws. x2 M6x55mm Long through bolt

1164/1164NS WIRELESS SMOKE DETECTOR

Remote Notification System Instruction Manual

Yale Assure Lock Electronic Interconnected Key Free Touchscreen Installation and Programming Instructions (YRC246)

Tech Support Line: (715) Concord 4 RE927X

INNCOM e7 Thermostat Installation Instructions FOR ALL UNITS IN CARTON. DO NOT THROW AWAY!

nextouch Touchscreen and Push Button Access Cylindrical Lock Installation and Programming Instructions

ISMV STREAMING MOTIONVIEWER

Yale Assure Lock SL Key Free Touchscreen Deadbolt Installation and Programming Instructions

with motion sensor ITM. / ART Model: LM55811 CARE & USE INSTRUCTIONS IMPORTANT, RETAIN FOR FUTURE REFERENCE: READ CAREFULLY

Yale Assure Lock Touchscreen Deadbolt Installation and Programming Instructions ( YRD226/YRD426)

Yale Assure Lock Touchscreen Deadbolt Installation and Programming Instructions ( YRD226/YRD426)

CLIP PG2 PowerG Wireless, Curtain, PIR Motion Detector

Model: ibt232 Bluetooth FM Clock Radio with USB Charging

LC-151 Dual-Tech Motion Sensor (Single PIR & Microwave) with adjustable Pet Immunity INSTALLATION INSTRUCTIONS & USER MANUAL P/N: ver.

Quick Start & Setup Guide

EL-TSTAT-8820 Owner s Manual

Compatibility. Contents. Necessary Tools

XV 210 GPRS Control Panel

Model: ibt297. Color Changing Bluetooth App Enhanced Speaker System. instruction manual. Questions? Contact Customer Service at

with Wi-Fi and local API Quick start and setup guide

Installer Guide smart connect

FTN-RRHW/FTN-RRIX FTN-RR2G/FTN-RRDS

Transcription:

SZ-PIR04N ZigBee Motion Detector Installation Guide SZ-PIR04N is a PIR (Passive Infrared) sensor, which can detect levels of infrared radiation from objects in its range of view. This Motion Detector is fully compatible with any ZigBee coordinator that are HA 1.2 certified. It is also a pet immune motion sensor, which is used to ignore the motion caused by animals and thus reduce the likelihood of false alarms. The sensitivity of the sensor will disregard the motion caused by animals under 85 pounds, like a full-grown dog or small cats. In addition, the SZ-PIR04N has walk test mode and white light immunity, which can be used to reduce false alarms caused by lights, flashlights or other reflective objects. These outstanding features of the sensor provides the professional security for protecting any home or business to save time, money and deliver a great surveillance experience as well. Specification Frequency 2.4 GHz Battery Type GP CR123A (1400 mah) * 2 RF Transmission Range Temperature Sensor Light Sensor Rearm Timer Operating Temperature Storage Temperature Battery Life Dimensions (H xw x D) Detect Range Outdoor: 300 Meters ±1 C Accuracy 0~2500 Lux 3 Minutes 0 C to 50 C (32-122 F) -20 C to 65 C (-4-149 F) 5 Years (Assume 30 events per day @25 C) 93.4mm x 50mm x 31.8mm Distance: Max. 15M (±1M) w/mounting height 1.8M @25 C Angle: Max. 90 (±10) Degree Package Contents Intallation 1. Detach the mount bracket from the device. 2. Install the provided batteries correctly. 3. Attach the mount bracket back to the device. 1

Operation 1. PIR LED (Red) 5. Battery Cover (Wall Mount Bracket) 2. Tamper Switch 6. Walk Test Switch 3. Pairing LED (Green) 4. Batteries When the batteries are installed, the PIR LED will be blinking for 30 seconds and then turn off when the Motion Sensor is ready to be used. After the tamper switch is pressed, the Motion Detector will be in normal mode. The PIR LED on the device will illuminate when the Motion Detector is triggered. The motion sensor needs to be checked and perform walk test annually to make sure the detection function is working properly. Adding to a ZigBee Network Join Function After installing the batteries, the Join/Leave (Green) LED will start blinking every 5 seconds which indicates SZ-PIR04N is ready to join a ZigBee network. The device will attempt to joing a ZigBee network for 20 times (100 seconds). If all attempts fail, SZ-PIR04N will stop joininig process, and need to press and release the tamper again to start joinging process. Leave Function For Leave a network, please do the following instruction: Press and hold the tamper switch while installing the batteries. Release the tamper switch within 4 seconds and the device will be reset to factory default. Walk Test 1. Remove the batteries and adjust the Walk Test Switch setting to On to enable Walk Test. 2. Install the batteries and rearm timer will be configured to 5 seconds for installers to test the detection coverage. 3. Remember to adjust the switch setting back to Off (normal mode) after walk test finished to save battery power. 2

Mounting Instruction The recommended mounted position for a Motion Detector should be 1.8M from the floor in the corner of a room. At this height, the device can detect a movement up to 15M (±1M ) (see the following image). Also, in this position, the 90 degrees (±10 degree) fan-shaped detection pattern can normally offer greater protection than mounting on a flat wall. Before selecting a position, the following installation hints should be noted: 1. Do not position the Motion Detector facing a window or direct sunlight. The device is also not suitable for using in draughty area where air conditioner or fan been installed. The excessive wind may cause false alarm. 2. Avoid aiming directly near heat sources, eg: fires, radiators, boiler etc. 3. Mount the detector where possible, so that the logical path of an intruder would cut across the fan pattern rather than directly towards the device. 4. Before mounting the PIR, perform walk test to ensure the detection coverage. 3

Wall Mounting Note: The device is suggested to be set at 90 degrees angle, which is the best mounted position for offering the 15M protection area. 1. Detach the mount bracket from the device. 2. Mount the bracket with the supplied screws/anchors into the wall. It can be either mounted on a flat surface or in a corner. Note: Make sure the mount bracket is installed in the correct direction (upwards arrow). 3. Attach the device to the mount bracket. 4

FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/tv technician for help. To assure continued compliance, any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. (Example - use only shielded interface cables when connecting to computer or peripheral devices). FCC Radiation Exposure Statement This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Canada Statement This device complies with Industry Canada s licence-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause interference; (2) This device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence. L exploitation est autorisée aux deux conditions suivantes : (1) l appareil ne doit pas produire de brouillage; (2) l utilisateur de l appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d en compromettre le fonctionnement. The device meets the exemption from the routine evaluation limits in section 2.5 of RSS 102 and compliance with RSS-102 RF exposure, users can obtain Canadian information on RF exposure and compliance. Le dispositif rencontre l'exemption des limites courantes d'évaluation dans la section 2.5 de RSS 102 et la conformité à l'exposition de RSS-102 rf, utilisateurs peut obtenir l'information canadienne sur l'exposition et la conformité de rf. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body. Cet émetteur ne doit pas être Co-placé ou ne fonctionnant en même temps qu'aucune autre antenne ou émetteur. Cet équipement devrait être installé et actionné avec une distance minimum de 20 centimètres entre le radiateur et votre corps. UL Notices: This device complies with UL Standard UL639. SZ-PIR04N V1.0 PN: 957BXL0201 Issue Date: 2016/11/15 5