INSTALLATION INSTRUCTIONS

Similar documents
INSTALLATION INSTRUCTIONS

Installation & Maintenance Instructions

Installation and Maintenance Instructions. Model Saf-T Pipe. Heavy Duty Black Stove Pipe. (Also known as a Connector Pipe)

TYPE L VENT / VENT SYSTEM FOR PELLET BURNING APPLIANCES

DT-M Direct-Temp for Multi Fuel L-Vent / Vent System for Pellet, Corn and other Bio-Fuel Burning Appliances

MODEL CF CEILING SUPPORTED CHIMNEY

PelletVent. Factory-Built Chimney Relining. Installation Instructions. PelletVent Pro (PVP)

EXCEL. ULTRABlack THE MOST DURABLE, EASIEST TO INSTALL RESIDENTIAL CHIMNEY SYSTEM YOU CAN BUY NEVER EVER BUY ANOTHER STOVE PIPE

INSTALLATION AND MAINTENANCE INSTRUCTIONS. 1700ºF Air-Cooled and Insulated ECO-STEEL Chimney Size 13

INSTALLATION INSTRUCTIONS

Z-VENT MODEL SVE SERIES III INSTALLATION AND MAINTENANCE INSTRUCTIONS

By Bernard Dalsin Mfg. Co. Installation and Operating Instructions Read these instructions and keep them for future reference

Pellet Vent INSTALLATION INSTRUCTIONS

Pellet Stove. Flex Pipe. Appliance Connector

Vertical Vent Kit for Bosch AquaStar Models GWH-1600H and GWH-1600P only. INSTALLATION INSTRUCTIONS for H/P VVT vent kit 5" GALVANIZED TYPE B GAS VENT

5"x 8" DIRECT VENT INSTALLATION INSTRUCTIONS FOR DECORATIVE GAS APPLIANCES AND DIRECT VENT HEATERS APPLICATION

CHIMNEYS AND VENTS CHAPTER 8

CHAPTER 8 CHIMNEYS AND VENTS

Corr/Guard PRESSURE RATED VENTING SYSTEM IMPORTANT: DO NOT INSTALL WITHOUT FIRST READING THESE INSTRUCTIONS VERY CAREFULLY.

Pellet Vent INSTALLATION INSTRUCTIONS

CHAPTER 8 CHIMNEYS AND VENTS

X-593 SOLID FUEL HEATING QUESTIONNAIRE

User s Manual WS-69TB30 / WS-69TB36 (22 ) WS-69TB42 / WS-69TB48 (22 ) WS-69TS30 / WS-69TS36 (18 ) WS-69TS42 / WS-69TS48 (18 )

GAS FIRED BOILERS FOR FORCED HOT WATER VENTING ADDENDUM. ECR International Ltd. - Olsen Division P.O. Box 900 Wallaceburg, Ont.

Corn Flame Energy Corn Stove Model 3000

Shasta Vent Inc All-Fuel HT Chimney Installation Instructions

H35 Direct Vent Gas Stove. 17,500 BTU/h (5.13 kw) 34,000 BTU/h (9.97 kw) 15,000 BTU/h (4.39 kw) 28,500 BTU/h (8.35 kw)

H35 Direct Vent Gas Stove. 17,500 BTU/h (5.13 kw) 34,000 BTU/h (9.97 kw) 15,000 BTU/h (4.39 kw) 28,500 BTU/h (8.35 kw)

VP Pellet Pipe. For pellet burning stoves. FEATURES

User s Manual WS-62N30SS WS-62N36SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

OWNERS MANUAL LIBERATOR ROCKET HEATER Model: RMH-1

Installation Instructions

User s Manual WS-4830SS WS-4836SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

User s Manual WALL MOUNT SERIES TABLE OF CONTENTS RA7730SS/RA77B30SS RA7736SS/RA77B36SS RA7742SS/RA77B42SS RA7748SS/RA77B48SS.

SUBJECT: SELKIRK MODEL DT DIRECT VENT SYSTEM FOR PELLET & CORN FIRED APPLIANCES / TERMINATION CLEARANCES TO OPENINGS IN BUILDINGS

St. Croix Greenfield Installation Manual

SMALL DIAMETER CORR/GUARD & SLEEVED CORR/GUARD

INTRODUCTION TO HITZER STOVES INSTALLATION AND OPERATION

FLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS

For Masonry & Factory Built Fireplace Retro-Fits Revised 5 December 2013 Healthy Hearth Riverside Dr. #214 Lake Elsinore, CA 92530

FIREPLACE INSERT, MODEL VOLCANO PLUS OWNER S MANUAL - INSTALLATION - OPERATION. Save These Instructions for Future Reference.

LISTED. Installation Instructions Covering - General Installation Instructions & Owner s Maintenance Guide. Sheet

FIREPLACE SIZES FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VACINITY OF THIS OR ANY OTHER APPLIANCE.

INSTALLATION AND OPERATING INSTRUCTIONS TABLE OF CONTENTS IMPORTANT

OWNERS MANUAL MODEL DO110 & DO180 IS CERTIFIED TO: Unit Serial # Purchased From Company Address

Ventis Direct Vent. Installation Instructions

Twin Wall Installation Instructions And Maintenance Guide

BDM Direct Vent systems are for use with direct vent gas fired appliances.

qüé=`üáãåéó An effective chimney is an important part of any successful wood-burning system.

PelletVent Pro. Installation Instructions. C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y

User s Manual ISLAND SERIES TABLE OF CONTENTS RA-7630SS RA-7636SS RA-7642SS RA-7648SS. Table of Contents. Safety Information...

User s Manual WS-63TB36SS WS-63TB42SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

HOMEOWNER'S GUIDE FOR YOUR CONTEMPO FIREPLACE TABLE OF CONTENTS

WS-5530SS WS-5536SS WS-5542SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

INSTALLATION AND SERVICE MANUAL

Table of Contents. Safety Information Content Checklist Measurements Preparation Installation

Installation and service must be provided by a qualified installer, service agency or the gas supplier.

User s Manual WS-3230SS WS-3236SS WS-3242SS WS-3248SS

User s Manual WS-5830SS WS-5836SS WS-5842SS

Malm Fireplaces, Inc. 368 Yolanda Avenue, Santa Rosa, CA (707) Fax: (707)

A MAJOR CAUSE OF CHIMNEY-RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS

C. Manufactured double wall chimneys for fuel fired equipment. D. NFPA 54 - National Fuel Gas Code; National Fire Protection Association; 2009.

ASX7-5-IOM-3 J

Operating and Installation Instructions

PelletVent Multi-fuel venting system. UL 641.

Gas Stoves. H15-10 Direct Vent Gas Stove. Model H15-NG10 H15-LP10. Approved Venting Systems

ASX7-4-IOM-6 J

Gas Stoves. C34-10 Direct Vent Gas Stove. Side wall E F. Back wall F E. Model C34-NG10 C34-LP10

INSTALLATION AND OPERATION GUIDE FOR HARGROVE GAS LOGS

M1200 Series Limited Warranty Dependability Promise

Installation and Maintenance Instructions

Easy to assemble. Silicone gasket sealed. Laser-welded seams. Smooth joint connections. 360 Lock-Tab secure rotation

CHIMNEY INSTALLATION. Technical Bulletin #1

INSTALLATION INSTRUCTIONS

Installation and Maintenance Instructions

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Air-O Ultra Series Range Hoods

FE1 Series Ventilation Fans 2007 Soleus Air International. Soleus Air Ultra Quiet Ventilation Fan

Section 1 - Safety Information Section 2 - Installation: Wall Mount Hoods Section 3 - Installation: Island Mount Hoods

Installation Instructions. Venting System for Pellet, Corn, Oil, and Biofuel appliances. PelletVent Pro

Read All Instructions Thoroughly Before Installing or Using the Disposer.

FACTORY-BUILT FIREPLACE MODEL OWNER S MANUAL - INSTALLATION - OPERATION

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE 06E Series Model 06E Series Model RANGE HOOD LOCATION 1. The range hood must be installed just above the

Side by side. Cascade Venting System for RTG 199HE. Extension Set for units 3 or Installation instructions

ELECTRONIC FIREPLACE DAMPER

SAFETY NOTICE FEATURES PREPARATIONS INSTALLATION OPERATION

Bathroom Exhaust Fan

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

DuraTech. Installation Instructions. Combustion Air System

Vertical Termination Part No: 3CGRVT 16 7/8" 18 Vent Pipe Extension Part No: 3CG18 9 7/8" Wall Hanger Part No: 3CGWH 7 7/8" 7 3/8"

HYBRID-FYRE FLUSH WOOD INSERTS

User s Manual RA-3030SS RA-3036SS. NOTE: This unit was designed for indoor residential use and DUCTED operation only.

breeze easytm model # F100-1W

Venting of Gas Fired Equipment RV

CAUTION FOR YOUR SAFETY

Back to back. Cascade Venting System for RTG 199HE. Basic Set for units 1 and Installation instructions

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

INSTALLATION AND OPERATING MANUAL

GB162 Concentric Horizontal Vent Kit

OVATION SERIES FIRE TABLES ASSEMBLY INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS

Transcription:

INSTALLATION INSTRUCTIONS FACTORY BUILT CHIMNEY CONNECTOR A MAJOR CAUSE OF CHIMNEY CONNECTOR RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF THE UTMOST IMPORTANCE THAT THIS DOUBLE WALL CHIMNEY CONNECTOR BE INSTALLED ONLY IN ACCORDANCE WITH THESE INSTRUCTIONS C US LISTED Tested to *UL103HT & ULC-S641 PLEASE READ ALL INSTRUCTIONS BEFORE BEGINNING YOUR INSTALLATION. FAILURE TO INSTALL THIS SYSTEM IN ACCORDANCE WITH THESE INSTRUCTIONS WILL VOID THE CONDITIONS OF CERTIFICATION AND THE MANUFACTURERS WARRANTY. KEEP THESE INSTRUCTIONS IN A SAFE PLACE FOR FUTURE USE. SELKIRK CANADA CORPORATION P.O. Box 526, Depot 1 Hamilton, Ontario L8L 7X6 905-662-6600 Fax 905-263-9308 1-800-263-9308 Toll Free Fax 1-866-835-9624 www.selkirkcanada.com 19/03/04 SELKIRK LLC 14801 Quorum Drive Dallas, Texas, USA 75240 972-560-2000 Fax 972-560-2428 1-800-992-VENT (8368) Toll Free Fax 1-877-393-4145 www.selkirkinc.com RM19896-1

TYPES OF APPLIANCES Your Connector is intended to connect a gas, liquid, or solid fuel appliance normally producing flue gases of 650 C/ 1200 F (Canada), 540 C/1000 F (US - to the Temperature requirements of UL103HT) or less to a factory built or masonry chimney. ATTENTION! The orientation of all chimney connector components must be with the crimped end (outer black pipe) pointing up, towards the chimney (see diagram below). This Connector must not be enclosed or pass through attics, closets, floors, walls or ceilings, and must not be used in place of an insulated chimney section. The Minimum Clearance to combustibles (i.e.. walls, ceilings, etc.) is 6" (152mm). For mobile home installations follow the installation instructions for the mobile home appliance and use the chimney connector clearance required by the appliance. Outer Black Pipe with crimped end pointing up toward the chimney Inner Pipe with crimped end pointing down into the appliance flue outlet PRE-INSTALLATION GUIDELINES Plan the installation of your appliance and chimney connector in such a way that your chimney connector run is as short and straight as possible. By having too long and/or multiple bend installations you can reduce system draft which can affect the operation, and/or performance of your appliance and/or chimney system. Ensure that you obtain any necessary building permits, and that your installation will conform with all federal and municipal building code requirements. Before commencing installation: CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA. Use this chimney connector only with an appliance listed by a recognized testing authority such as Intertek Testing Services (Warnock Hersey), CSA, Underwriters Laboratories Inc., or Underwriters Laboratories of Canada. The maximum recommended length of Double Wall Stove Pipe should not exceed 20ft. Reduce this maximum limit by 10% for every 90 bend or 5% for every 45 bend. Provide sufficient slope in the horizontal run of the chimney connector (20mm per meter, 1/4" per foot) to enable any condensed liquid or creosote to run back toward the appliance. Ensure that the horizontal chimney connector is securely supported from the structure by means of metal or other noncombustible supports at intervals not exceeding 1m (3ft). All joints between sections of the chimney connector must be secured with three sheet metal (supplied) screws per joints. The black surface of the chimney connector may be touched up with a high temperature flat black stove paint. If you are upgrading from a single wall stove pipe to the Double Wall Stove Pipe Connector, have your chimney inspected by a certified wood technician or a certified chimney sweep. PARTS CHECK LIST To complete a proper Double Wall Stove Pipe installation, the following parts may be required: Adjustable Length Universal Adapt 6" Pipe Length 12" Pipe Length 24" Pipe Length 36" Pipe Length 45 o Elbow 90 o Elbow Tee Section Masonry Adapter Damper Kit Band Stove Adapter Oval to Round Adaptor Flush Stove Adaptor DSP*TL DSP*AL-1 DSP*CA DSP*P6-1 DSP*P12-1 DSP*P24-1 DSP*P36-1 DSP*E4-1 DSP*E9-1 DSP*TE-1 DSP*MA DSP*DK-1 DSP-FB DSP*SA-1 DSP8OTR DSP*FSA-1 * Denotes size of product 6"(152mm), 7"(178mm), 8"(203mm) INSTALLATION PROCEDURES Install the appliance and chimney system according to the installation instructions provided with them, ensuring that the required clearances are maintained SECURING OF THE DOUBLE WALL STOVE PIPE (DSP) The following is to assist you in connecting the Double Wall Stove Pipe (DSP) to the system. There are two (2) connecting methods. A Band (packaged with all Telescopic and Adjustable Lengths) or it may be purchased separately (DSP-FB). The second method is with the Universal Adaptor. Both methods can also be utilised on other chimney systems. In all installations, all single wall parts of the chimney pipe adaptor must be fully covered by the Band or the Universal Adaptor. In order to accomplish this some trimming may be required.

INSTALLATION OF THE UNIVERSAL CHIMNEY STEP 1 : Slide the Universal Adapter (CA) over the male end of either the Stove Pipe Adapter (ASE) or the Smoke Pipe Adaptor all the way until snug to bead and beveled edge. See Figure 1. Step 2. Pre-drill 3 evenly spaced holes into the crimped end of the DSP through the Pipe Adaptor with a 3/32 metal drill bit. Secure in place with 3 #8 X 1/2 stainless steel sheet metal screws (not supplied). UNIVERSAL CHIMNEY (CA) Beveled edge SUPERVENT'S CHIMNEY PIPE (ASE) UNIVERSAL CHIMNEY (CA) STEP 2 : Pre-drill 3 evenly-spaced holes into the Universal Adapter (CA) with a 3/32 metal drill bit. See Figure 2. These holes must also pierce the Stove Pipe Adapter (ASE) and the Smoke Pipe Adaptor. SUPERVENT SELKIRK SELKIRK'S CHIMNEY PIPE FIGURE 1 Pre-drill 3 holes evenly-spaced with a metal bit. See Step 2. Pre-drill 3 holes evenly-spaced with a metal bit. See Step 2. FIGURE 2 STEP 3 : Secure in place with 3 metal screws #6 X 1". NOTE: Tigthen screws until head meets metal casing. Do not over tightnen the screws such that the outer casing becomes deformed. INSTALLATION OF FINISHING BAND (FB) Step 1. Position the to the appropriate location over the Pipe Adaptor. Ensure that it s final position will be covered by the Band which is only 3 wide. The Band must overlap the crimped end of the DSP and the bead to the beveled edge of the Pipe Adaptor or to the Basecap (see Figure 1A). Supervent/Superpro Assembly Figure 1B Band Installed Step 3. Wrap the Band over the crimped end of the DSP and the Pipe Adaptor. Ensure it is over the bead and snug to the beveled edge or to the Basecap. Mark this position using the 2 pre-punched holes in the Band as a template. Pre-drill with a 3/32 metal drill bit and secure the Band with the 2 supplied black sheet metal screws. Figure 1B shows when it is all assembled. Step 4. On a Through-The-Wall Installation with a 90 degree elbow, it may be necessary to cut the Pipe Adaptor and /or the Band to the required width to be covered. Ensure that the Band overlaps the crimped end of the DSP and overlaps the bead snug to the beveled edge or to the Basecap as per Figure 2A & 2B. Band 90 Degree Elbow Section Telescopic Length 90 Degree Elbow Band Pipe Adaptor Selkirk Assembly Figure 2A Supervent/Superpro Assembly Band to overlap the Bead and snug to the Beveled edge of the Pipe Adaptor Position Band over the crimped end Pipe Adaptor Band Telescopic Length Position Band snug to the Basecap Position Band over the crimped end Basecap Figure 2B Selkirk s Assembly Figure 1A Supervent/Superpro Assembly Selkirk Assembly

INSTALLATION TYPE #1 (See Figure A) This installation is used when the chimney system is located immediately above the appliance. 1. Place the on top of the appliance with the male (crimped) end up, and the female end over the appliance outlet collar. Attach it with the 3 metal screws supplied. If the collar of your appliance is too large for the to fit over you will have to use a stove adapter on top of the stove before installing the. 2. If using an Universal Adaptor place it on top of the Telescopic Length and secure it in place with the 3 metal screws supplied. If using the Band see "Installation of Band". 3. Extend the until the Adapter slides over the stove pipe adapter and secure the upper and lower sections of the in place with the 3 metal screws supplied. If the installation requires more length than provided by the telescopic length then install the fixed length(s) on the appliance and the telescopic length next to the chimney. All connections are to be fastened together with the 3 metal screws provided with each length. Insulated SectionLength FIGURE -Bsal Adaptor to the top of the Tee. Secure the sections together with the 3 metal screws supplied ensuring that the elbow is properly aligned for connection to the. See "Installation of Band" if used. 3. Install the Elbow/Tee/ Adapter assembly to the top of the Telescopic Section and secure the sections together with the 3 metal screws supplied. 4. Extend the until the Adapter slides over the chimney connector and secure the upper and lower sections of the in place with the 3 metal screws supplied. If the installation requires more length than provided by the telescopic length then install the fixed length(s) on the appliance and the telescopic length next to the 90 o Elbow. All connections are to be fastened together with the 3 metal screws provided with each length. Insulated Section Ceiling Support Pipe Adapter Band or Universal Adapter 90 o Elbow Support Pipe Adapter Band or Universal Adapter Tee Section FIGURE -A- INSTALLATION TYPE #2 (See Figure B) This installation utilizing a Tee Section, is used when the chimney system is offset from the appliance, either to maintain proper clearances for the appliance or for incorporating a cleanout in the chimney system. 1. Place the on top of the appliance with the male (crimped) end up, and the female end over the appliance outlet collar and attach it with the 3 metal screws supplied. If the collar of your appliance is too large for the to fit over you will have to use a stove adapter on top of the stove before installing the. 2. Install the 90 o Elbow to the Tee Section branch and the Univer- INSTALLATION TYPE #3 (See Figure C) This installation is used when a factory built chimney system is located through the wall behind the appliance. 1. Place the on top of the appliance with the male (crimped) end up, and the female end over the appliance outlet collar. Attach it with the 3 metal screws supplied. If the collar of your appliance is too large for the to fit over you will have to use a stove adapter on top of the stove before installing the. 2. Install a 90 o Elbow to the Adapter and then to the chimney connector coming through the wall, ensuring that the elbow is properly aligned for connection to the. If the clearances of the appliance requires a greater horizontal distance than that provided by the 90 o Elbow, install the required connector length to the elbow first, and then install your Adapter and secure the pieces together with the 3 metal screws provided. If using the Band see "Installation of Band".

3. Extend the until it connects with the 90 o Elbow and secure the upper and lower sections of the Telescopic Length in place with the 3 metal screws supplied. Fasten the and the 90 o Elbow together with the 3 metal screws provided. If the installation requires more length than provided by the telescopic length then install the fixed length(s) on the appliance and the telescopic length next to the 90 o Elbow. All connections are to be fastened together with the 3 metal screws provided with each length. Pipe Adapter Band or Universal Adapter 90 o Elbow Insulated Sections Insulated Tee Section FIGURE -D- Fixed Length 90 o Elbow 3 Metal Screws Masonry Adapter Liner Masonry Wall Thimble 12" Insulated Section Wall Support Bracket INSTALLATION TYPE #4 (See Figure D) FIGURE -C- This installation is the same as Installation Type #3 with the exception that the connecter is run to an existing Masonry instead of a Factory Built. 1. If your existing Masonry does not have a Liner installed, it is required one be installed in order to make a proper connection to the Double Wall Stove Pipe. 2. Once your liner is in place, make sure the opening in the or liner is the correct size to accept the Masonry Adapter. Slide the Masonry Adapter into the opening in the chimney and into the branch of the Liner Tee until the collar of the Adapter fits flush to the wall of the chimney. If Masonry Adapter is too long and the collar does not fit flush to the wall, or it projects too far into the Tee the Adapter should be trimmed for proper fit. The Adapter should fit snug and not loose and there should be no gaps where heat or products of combustion might escape. If the adapter is loose fitting or gaps are present when it is installed they should be filled with a suitable filler. 3. After installing the Masonry Adapter follow the instructions in Installation Type #3. RULE FOR SAFE OPERATION AND MAINTENANCE Do not use fuel materials corrosive to the chimney such as driftwood, chemically treated wood or garbage or over fire your solid fuel appliance. This can cause failure of the DSP Double Wall Stove Pipe and will void any warranties. When wood is burned slowly, it produces tar and other organic vapors, which combine with expelled moisture to form creosote. The creosote vapors condense in the relatively cool chimney flue of a slow-burning fire. As a result, creosote residue accumulates on the flue lining. When ignited, this creosote makes an extremely hot fire. With a new installation, the chimney should be inspected frequently (every 2 weeks if need be) to determine the rate of creosote formation. When familiar with the appliance and chimney characteristics, the chimney should be inspected at least once every 2 months during the heating season to determine if a creosote or soot build-up has occured. If you see deposits more than 2mm (1/16") thick, clean all connector pipe and chimney system mechanically (with a properly sized plastic cleaning brush) to reduce the risk of chimney fire. Contact a local professional chimney sweep for chimney cleaing services and advice. Do not expect chemical chimney cleaners to keep your chimney clean. Their use does not negate the necessity of periodically inspecting and cleaning your chimney. KEEP YOUR CHIMNEY AND CONNECTOR CLEAN!

LIMITED LIFETIME WARRANTY LIMITED LIFETIME WARRANTY: Selkirk Canada Corporation, ( we, us, our ) warrants & Venting products * to be free from defects in material and workmanship for as long as the original consumer owns the system. For products installed after January 1, 2000, for a period of Ten (10) years from original installation, we will provide replacement product with a similar or like quality of available product, free of charge excluding any installation costs. From the Eleventh (11) through Fifteenth (15) years we will provide replacement product to the original consumer at a cost of 75% off the published Retail Price in effect on the date the claim is received excluding any installation costs. At expiration of the Fifteen (15) year term, we will provide replacement product to the original consumer at a cost of 50% off the published Retail Price in effect on the date the claim is received excluding any installation costs. LIMITATIONS: - Products must be installed for their intended purpose. - Products must be connected to an appliance listed with an accredited testing laboratory. WARNING: FAILURE TO INSTALL PRODUCTS ACCORDING TO THE MANUFACTURER S INSTRUCTIONS WILL VOID ALL APPLICABLE WARRANTIES AND MAY RESULT IN FIRE, CARBON MONOXIDE POISONING OR DEATH. SEE OUR PRODUCT INSTALLATION INSTRUCTIONS FOR COMPLETE INSTRUCTIONS. WARRANTY COVERAGE: All lengths, tees and elbows, and components are applicable to warranty coverage. THIS LIMITED WARRANTY DOES NOT COVER: (a) any non-stainless base tee unit mounted or connected to an Insulated system; (b) costs (labor or otherwise **) associated with either removing a previously installed product, installing a replacement product, transportation or return of a product, or transportation of replacement product; (c) damage to the finish of products caused by the use of improper solvents/chemicals or improper cleaning methods; (d) damage resulting from failure to reasonably clean, care for or maintain products in accordance with our installation instructions/ recommendations; (e) damage (to products, appliances or structure) based on or resulting from improper installation or repair, misuse or abuse (including, but not limited to, excessive or improper operating condition), or alteration or adjustment other than in conformity with our installation instructions and specifications, whether performed by a contractor, service company, technician, or yourself; (f) any products that have been moved from their original installation site. (g) damage caused by burning driftwood, garbage, or any other prohibitive material has been burned in the appliance served by the chimney (h) damage that results from accidents such as fire, flood, high winds, acts of God, or any other contingency beyond our control. ** Due to the wide variance in installation practices and other conditions beyond our control, we do not guarantee or in any way warrant the installation of and Venting products. CLAIM PROCEDURE: If you believe that a product is defective, notify us in writing at the following location: SELKIRK CANADA CORPORATION P.O. Box 526, Depot 1, Hamilton, Ontario, CANADA, L8L 7X6 ATTN: WARRANTY CLAIMS DEPARTMENT Fax: (905) 662-5352 Notification should include a description of the product, model and serial number (if applicable) and a description of the product defect. Upon receipt of a written claim under this limited warranty and evidence of the date of purchase or installation, at our option and in our sole discretion, we will provide replacement product with similar or like quality of available product excluding any installation costs. We reserve the right to inspect or investigate any warranty claims prior to determining whether to provide replacement product. If, as determined by us that repair or replacement of the product is not commercially practicable or cannot be completed in a timely manner, we may refund the prorated purchase price paid for the product upon verification by providing a copy of your invoice or receipt of bill of sale.

INSTALLATION INFORMATION keep in safe place for future reference MODEL OF CHIMNEY: TYPE OF APPLIANCE: INSTALLATION DATE: DESCRIPTION OF INSTALLATION ( and Connector configuration) PURCHASED FROM: DEALER NAME: Address: City: Province/State: INSTALLED BY: TECHNICIAN NAME: Address: City: Province/State: PRODUCT REGISTRATION Please register your with the Manufacturer. Register Online: www.selkirkcanada.com Name: Address: City: Province/State: Postal/Zip: Model: Installation Date: Dealer Name: