Alarm Fatigue in the ICU. Lynn Maguire MS, RN, PMC, NE-BC

Similar documents
Alarm Management. Objectives

Clinical Alarm Effectiveness: Recognizing & Mitigating Risk to Patient Care

You finally make it home after a long shift, shower,

The Joint Commission's National Patient Safety Goal on Alarm Management: How Do We Get Started?

Alarm Management at Boston Medical Center A Roadmap to Safe Silence

Clinical Alarm Management Strategies Meaningful Alerts

Improving Alarm Management Utilizing Technology. NJ/DVHIMSS Annual Fall Event. Empowering the New Healthcare Era

Reference Case: Avera Heart Hospital Data-Driven Approach Helps Hospital Build Effective Clinical Alarm Management Program

Managing Clinical Alarms

Why Clinical Alarms are a TOP TEN Hazard

Focus on Respiratory Care & Sleep Medicine Irvine, CA. Alarm Management. September 14-15, 2018

Hospital Ward Alarm Fatigue Reduction Through Integrated Medical Device Instruction and Hospital System Policy

"It's Alarming Simple Steps To Reduce Nuisance Alarms

Impact Of Clinical Alarms On Patient Safety. American College of Clinical Engineering Healthcare Technology Foundation (AHTF)

Alarm Safety in 2017:

Alarms That Deserve Attention. Mike Rayo 3/29/2016

A Novel Approach to Cardiac Alarm Management on Telemetry Units. Medical Device Alarm Safety in Hospitals Joint Commission Webinar May 1, 2013

Running head: REDUCING THE HARM ASSOCIATED WITH CLINICAL ALARMS 1

Ensuring the Effectiveness of Clinical Alarm Systems

The Contra Costa EMS System and Fire Station Closures: Impact and Mitigation

Capnostream 20p Bedside Capnography Monitor. The only integrated, complete picture of oxygenation and ventilation 1

Customizing Alarm Limits Based on Specific Needs of Patients

URGENT - Field Safety Notice Medical Device Correction

Alarm Management: Electrocardiographic Lead Management

URGENT: MEDICAL DEVICE CORRECTION Plum 360 Infusion System List Number: 30010

Safety Innovations FOUNDATIONHTSI. Plan, Do, Check, Act: Using Action Research to Manage Alarm Systems, Signals, and Responses

Ultraview SL2400 With Wireless-LAN-Option

ELECTRICAL SAFETY IN HEALTHCARE FACITILIES

Preventing ECMO Patient Harm While Using Remote Monitoring: A Case Report. Emily Thunstrom

Sound the Alarm! Strategies for Alarm Management in the Rush NICU. October 21 st, 2015

2011 National Clinical Alarms Survey: Perceptions, Issues, Improvements and Priorities

Kendall DL Cable and Lead Wire System. Your Disposable ECG Cable and Lead Wire Safety Solution. Safe, Simple, Secure

D Moving beyond telemetry INFINITY M300

AST Guidelines for Best Practices in Alarm Management in the Operating Room

False Alarm Suppression in Early Prediction of Cardiac Arrhythmia

Healthcare PROTEZIONE TOTALE PER I VOSTRI INTERESSI AZIENDALI PRESENTI E FUTURI. When every second counts, Honeywell delivers.

Ultraview SL Command Module Parameter Set ECG NIBP TEMP IP CO SpO2 Options SL Command Module: A B Our goals are simple:

qube mini Overview

2013 Compliance Report RCW 52.33

Propaq LT Outline Train the Trainer

Nellcor Bedside SpO 2 Patient Monitoring System, PM100N

Infinity M300 Patient Worn Monitoring

Clinical Alarm Management. Compendium

Central Monitor CNS Shown with options

Safety Innovations FOUNDATIONHTSI. Using Data to Drive Alarm System Improvement Efforts. The Johns Hopkins Hospital Experience

SOFTWARE VERSION 8.5 FAQs

GE Healthcare Healthcare Systems 9900 Innovation Drive Wauwatosa, WI USA

General Safety Policy Otolaryngology Head and Neck Surgery. Policy:

The Complexity of Clinical Alarm Systems

Regulation of Alarm Remote Notification Systems

Quick Reference Guide STAN S31 fetal heart monitor. Power ON/OFF. ST Analysis (Fetal ECG analysis)

Passport 12m and Passport 17m BEDSIDE MONITOR GUIDELINE 5.21 Software Version NAME: HOSPITAL: DATE: VALIDATOR: Performed

Battery Performance Alert

Battery Performance Alert: A TOOL FOR IMPROVED PATIENT MANAGEMENT FOR DEVICES UNDER BATTERY ADVISORY

June 17, Skanray Technologies Pvt Ltd. c/o Ms. Yolanda Smith Regulatory Consultant Smith Associates 1468 Harwell Avenue Crofton, Maryland 21114

Central Monitor. Central Monitoring System. Intuitive, Reliable, Flexible CNS-9601K. Shown with options

Optimization of Workflow Processes & Resources Through the Focused Deployment of Enabling Technologies

Austin Independent School District Police Department Policy and Procedure Manual

Hospital Preparedness: A Pilot Program for Radiation Monitoring in Emergency Departments

Spacelabs Healthcare - Connecting Innovation with Care

BeneVision TM80 Telemetry Monitor

Consumer Letter (Accu-Chek Insight E-7) Urgent field safety notice. Location, Date

GE Healthcare. Quick Guide. Dash 2500 Patient Monitor

General Skills. yes. Device controls, buttons, indicators, and connectors

Improving Clinical Alarm Management: Guidance and Strategies

80BPM 36.5 C 35/ / 80. Panorama CENTRAL MONITORING SYSTEM. efficient flexible versatile (18) (94) Adult A SMITH, ERICA (92) 5RPM.

Contents of ANSI/AAMI HE75:2009 Page

OMNI TOUCH SCREEN PATIENT MONITOR

SFGH, JOINT CONFERENCE COMMITTEE

Safety Innovations FOUNDATIONHTSI. Cardiopulmonary Monitors And Clinically Significant Events in Critically Ill Children

T1 BEDSIDE MONITOR GUIDELINE

Atlas Monitor Outline Train the Trainer

PATIENT MONITORING SYSTEMS

Nurse Call Systems & Emergency Call Systems. Overview of ANSI/UL 1069 and ANSI/UL 2560

AS/NZS IEC :2016

The Case for a Multi-Parameter Patient-Worn Monitor

Report For NHS Shetland

IntelliVue TRx/TRx + Transceivers

Cl inician Training Packet

City of Regina Alarm Bylaw

BeneVision Central Monitoring System. Quick Reference Guide

CITY OF MOUNTAIN BROOK FIRE DEPARTMENT

(Place Logo from Lab here)

Framework for Alarm Management Process Maturity

Infinity M300+ Telemetry

TPCA TM PATIENT CONTROLLED ANALGESIA SYRINGE PUMP

Safety Innovations FOUNDATIONHTSI. Recommendations for Alarm Signal Standardization And More Innovation. The Christiana Care Health System Experience

EXTERNAL CARDIAC AMBULATORY TELEMETRY

FIRE PLAN. In order to assure the safety of patients, visitors and staff, a standard response to fire or the potential of fire is required.

Clinical Information Center Pro v5 (CIC Pro)

Sample Content for the. FlipChart. Example: Medical Facility Emergency Preparedness Guide

Omni (K) PATIENT MONITOR

BUSINESS PLAN CEN/TC 215 RESPIRATORY AND ANAESTHETIC EQUIPMENT EXECUTIVE SUMMARY

University of Bristol. Sleep Study Suite. Standard Operating Procedures Version 1 November 2011

HeartStart XL+ Configuration Worksheet

No Cause for Alarm: A Holistic Approach to Identification, Prioritization, and Reduction

Health and Safety Documents in connection with offshore oil and gas operations

Building Analytics and Compliance: How analytics can be used to aid in performancebased certifications. Bryant M. Kirkland Jr, PE, CCP, LEED AP

GE Healthcare. Dash Variable-Acuity Monitoring

WELCOME TO ROSEVILLE UNIVERSITY

Transcription:

Alarm Fatigue in the ICU Lynn Maguire MS, RN, PMC, NE-BC

Objectives At the completion of this lecture the participant will: Define Alarm Fatigue Discuss the Joint Commission s Patient Safety Goal regarding Alarm Fatigue Identify the most common sources of Alarm Fatigue Identify a minimum of 3 contributing factors to Alarm Fatigue Identify 3 strategies to reduce nuisance alarms in the ICU

https://www.youtube.com/watch?v=i06judphm4e https://www.youtube.com/watch?v=ycpmxpiewlq &list=plkjyls13_xvv4to5nbjh7ryq1gpdneuyc&in dex=4

Definition Alarm Fatigue Occurs when staff members are exposed to an excessive number of alarms. Staff become desensitized to alarms. Results in sensory overload: Staff frustration Delayed alarm response Missed alarms Patient safety events

Alarm Sources

Contributing Factors

Unintended Consequences Since 2005, more than 216 patient deaths have been directly attributed to alarm fatigue. 77-year old was admitted to a telemetry unit. Alarms for low battery went unanswered. Patient had cardiac arrest and died.

Unintended Consequences January 2010 89-year-old patient was in the ICU. Bedside alarm was turned off. Alarm sounded at the central nurses station. Nurses on duty said they did not hear the alarm or see the digital display.

Unintended Consequences Patient Death August 2010 60-year-old man was admitted to the ICU after a tree fell on him, resulting in facial trauma and head injury. He was agitated and received lorazepam 5 mg IV push. The order was for small doses up to 5 mg. An hour later, tachycardia and low oxygen saturation (SpO 2 ) alarms went unanswered for an hour. Respiratory arrest was called. Patient was resuscitated and placed on a ventilator. CT scan showed an anoxic injury of the brain. Family withdrew the patient from life support after several days.

Statistics

Impact/significance Studies show it is difficult for humans to differentiate among more than 6 different alarm sounds The average number of alarms in an ICU has increased from 6 in 1983 to more than 40 different alarms in 2011. 80% to 99% of electrocardiographic (ECG) monitor alarms are false or clinically insignificant.

Research Results University of Utah observational study results 200 observational hours in an ICU 1,214 alarms 6.07/hour 145/patient day 5.7% were actionable patient-related alarms 17.7% were actionable technical alarms An alarm delay of 19 seconds would reduce alarm occurrence by 67%

Alarm Classifications False alarms (causes) Patient motion Poor sensor placement Intermittent cables Limitations in the device alarm detection algorithm Non-actionable alarms. True alarms that require no intervention and usually correct themselves Low O 2 Saturation Heart rate Suctioning Actionable alarms Need immediate action Life threatening

Joint Commission National Patient Safety Goal Background NPSGs were established in 2002 Patient Safety Advisory Group advises Joint Commission on the development & updating of NPSGs NPSGs developed in response to: Sentinel Events Survey findings Changes in standards

Joint Commission National Patient Safety Goal Clinical Alarm Safety Goal 6 Reduce the harm associated with clinical alarm systems Use alarms safely NPSG.06.01.01 Make improvements to ensure that alarms on medical equipment are heard and responded to on time.

JCAHO Sentinel Events Report January 2009-June 2012 98 Events reported to JCAHO involving alarms 80 resulted in patient deaths 13 resulted in permanent loss of function 5 resulted in unexpected additional care or extended stay Injuries/deaths/delays due to: Falls Delays in treatment Ventilator use Medication errors

JCAHO Sentinel Events Findings Alarm signals inappropriately turned off. Absent or inadequate alarm system. Alarm signals not audible in all areas. Improper alarm settings.

JCAHO Additional contributing factors included: Alarm fatigue. Alarm settings not customized to the individual patient or patient population. Inadequate staff training. Inadequate staffing to support or respond to alarms. Alarm conditions and settings not integrated with other medical devices. Equipment malfunctions and failures.

JCAHO Strategies Develop a multidisciplinary team to review trends and develop protocols. Ensure that there is a process for safe alarm management and response. Establish guidelines for alarm settings, including individualizing alarm settings and limits, when limits can be modified, and to what extent. Take appropriate measures to reduce the number of nuisance (false positive) alarms. Identify when alarm signals are not clinically necessary. Clarify who is responsible for alarm notification and response.

JCAHO Strategies con t Assess the acoustics in the patient care area and modify as needed to ensure that critical alarms can be heard. Develop clear protocols for handoff communication Routinely inspect and maintain alarm-equipped devices. Carefully analyze potential alarm-related problems. Adequately train staff. Build a culture of safety.

Expected Practice and Nursing Actions Provide proper skin preparation for ECG electrodes Wash the isolated electrode area with soap and water, wipe the electrode area with a rough washcloth or gauze, and/or use the sandpaper on the electrode to roughen a small area of the skin Do not use alcohol for skin preparation; it can dry out the skin

Expected Practice and Nursing Actions Customize alarm parameters and levels on ECG monitors Customize the alarms to meet the needs of individual patients Set customized alarms within 1 hour of assuming care of a patient and as the patient s condition changes Change ECG electrodes daily. Change daily or more often if needed

Expected Practice and Nursing Actions Customize delay and threshold settings on oxygen saturation via pulse oximetry (SpO2) monitors. Collaborate with an interprofessional team, including biomedical engineering, to determine the best delay and threshold settings Use disposable, adhesive pulse oximetry sensors, and replace the sensors when they no longer adhere properly to the patient s skin.

Expected Practice and Nursing Actions Provide initial and ongoing education about devices with alarms Provide education on monitoring systems and alarms, as well as operational effectiveness, to new nurses and all other health care staff on a periodic basis Budget for ongoing education when purchasing monitoring systems.

Expected Practice and Nursing Actions Establish interprofessional teams to address issues related to alarms, such as the development of policies and procedures Determine the default alarms for the equipment being used Evaluate the need to upgrade to next-generation pulse oximetry Consider developing a culture of suspending alarms when nurses perform patient care that may produce false alarms DO NOT TURN ALARMS OFF! Standardize monitoring practices across clinical environments

Expected Practice and Nursing Actions Monitor only those patients with clinical indications for monitoring Collaborate with an interprofessional team to determine those patients in a population or care unit who should be monitored and what parameters to use Use the American Heart Association s Practice Standards for ECG Monitoring in Hospital Settings: Executive Summary and Guide for Implementation

SpO 2 Alarm Suggestions Single-patient use sensors for continuous monitoring Proper placement of SpO 2 sensor Cable maintenance and routine replacement Decrease alarm thresholds from 90% to 88% Set a 15 second alarm delay

Alarm Optimization

Toolbox of Alarm Management Resources AACN Practice Alert (http://www.aacn.org/practicealerts) The Joint Commission proposal: 2014 National Patient Safety Goal on Alarm Management ECRI Institute (http://www.ecri.org) Healthcare Technology Foundation (http://thehtf.org) U.S. Food and Drug Administration Medical Devices (http://www.fda.gov/default.htm) Advancing Safety in Medical Technology Healthcare Technology Safety Institute (http://www.aami.org/htsi/) Industry partners Physiologic monitoring system manufacturers Ventilator manufacturers Infusion pump manufacturers Pulse oximetry device manufacturers Bed manufacturers Wired and wireless communication systems manufacturers

References http://psqh.com/alarm-fatigue-hazards-the-sirens-are-calling http://www.aacn.org/practicealerts http://www.ecri.org http://www.fda.gov/default.htm http://www.aami.org/htsi/) Welch, J. (2011, Spring). An evidence-based approach to reduce nuisance alarms and alarm fatigue. Horizons, 46-52. Ulrich, Beth; Nephrology Nursing Journal, 2013 Jul-Aug; 40 (4): 293-346.