PZ2 Series Manual. PROZONE INTERNATIONAL, Inc. Ozone Water Purification Systems. INSTALLATION GUIDE and OPERATION MANUAL. Prozone PZ2 Series

Similar documents
Ozone Generator Systems

Ozone Generator Systems

PZ1, PZ3 & PZ6 Installation Guide

EcoMaster - Residential Pools up to 40,000 Gallons

EcoMaster - Residential Pools up to 40,000 Gallons

Vacuum-ultraviolet Ozone Systems. Installation & Operation Manual. Model OZ-SPA

Next Generation Corona Discharge Installation & Operation Manual

FOR THE RECORD. You should record the model and serial numbers, which can be found on the back of the unit, for future reference.

OZONE SYSTEM FOR IN-GROUND POOLS New and Existing

OZONE SYSTEM FOR IN-GROUND POOLS UP TO 18,000 GALLONS

IMPORTANT SAFETY INSTRUCTIONS EC-AG1-25 EC-AG1, EC-AG2 SAVE THESE INSTRUCTIONS.

Important Safety Instructions

Copyright. Prozone Water Products,Inc. phone: fax:

READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

A2Z Ozone, Inc. PRODUCT MANUAL

Next Generation Corona Discharge Next Generation Corona Discharge Nueva generación Corona de descarga

register your product at a2zozone.com/pages/warranty SP Series Operating Manual

READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

1, 2, & 4. Corona Discharge Ozone Generators INSTALLATION & OPERATION MANUAL. DEL Ozone SAN LUIS OBISPO, CA USA Fax:

Air Preparation System

WATER PURIFYING SYSTEM

DEL AOP 25 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL

Ultraviolet Systems UV-C 50 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL

Owner s Manual RD432-0 Chemical Controller

Clear Comfort Residential Pool & Spa Sanitization System Installation, Operations & Maintenance Manual

2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP

Air Preparation System

M790 ph/orp Controller. Owner s Manual

MAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP

Ozone Systems. Installation & Operation Manual CD15nx CD30nx. Corona Discharge Ozone Generators. ClearWater Tech, LLC. Integrated Ozone Systems

Electrical Field. Molecular weight: 48. Color: Solubility: Ozone leaves no telltale taste or odor.

Owner s Manual. Installation, Operation and Maintenance SC-OZ, SC-OZ/2, S2Q-OZ, S2Q-OZ/2, S8Q-OZ, S8Q-OZ/2. Manufactured in Canada by:

WINTERIZATION INDUSTRY BEST PRACTICE

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

Installation and Operation Manual. ACF-18 Automatic Chlorinating Feeder

PATENTED APG OZONE CELLS DESTROYS HARMFUL CONTAMINANTS REDUCE CHEMICAL DEMAND

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA.

INSTALLATION INSTRUCTIONS

M770 ph Controller Owner s Manual

Installation and Operation manual WARNING

BALLAST REPLACEMENT. Contents WARNING INSTALLATION MANUAL

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Installation & Operation Manual. AromaFlo. mr.steam. Feel Good Inc.

Ozone + UV Sanitation

Ozone plus UV Sanitation System Installation & Operations Manual

OPERATORS MANUAL FOR Mi-T-M CORONA DISCHARGE OZONE GENERATORS

VMUS-4 Ozone Generator

Sidel Combi-Combi Therm & CO2 Counter Installation Guide

#300 & #302 CHLORINEIBROMINE FEEDERS

O 3 SYSTEM. Taming the elements

OZONE 101. Alternative Swimming Pool Sanitation Technologies

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Water Technologies. Strantrol System 3i. Technical Guide

Sundance Spas SPA EQUIPMENT SYSTEM. Installation Instructions. P/N Rev. A

INSTALLATION MANUAL. PP2 Ozone System (No Filter Cartridge) PP3 Ozone System (With Filter Cartridge) nspdevelopment.com

geyser spas OWNERS MANUAL

INSTALLATION, OPERATION AND SERVICE MANUAL AERATION SYSTEMS FEATURING AIR COMPRESSOR AND AIR ELIMINATOR TANK

OWNER S MANUAL. Models: AC110, AC125, AC150 made from 2003 through Proudly Made in the USA

OWNER S MANUAL. Vintage Classic HEAT COOL models. Proudly Made in the USA

CONTENTS CONSIDERATIONS. General Plumbing Component Connection ILLUSTRATION. Control System CONFIGURATION. Voltage Verification CONNECTION

Installation. Leveling

Arch Feeder: Installation Manual

J-PRO V 230V Dual Voltage Chlorinator Installation & Start-Up Guide

STOP. SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product.

ZO-400 & ZO Installation & Operations Manual

Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324

Technical Note # 01.05

M820 ph/dual ORP Controller. Owner s Manual

RIVERSOFT Water Softener System

Next Generation Corona Discharge Auto Voltage Sensing Installation Manual

Owner s Manual. Keep with machine for reference PKC24 INSTALLATION & OPERATION REV Perlick Corporation 8300 W Good Hope Rd Milwaukee, WI 53223

Model NFF Iron, Manganese, Hydrogen Sulfide Reduction

INSTALLATION. Glass Panel Doors (select models) CAUTION

J-PRO-24 Pump Chlorinator. Installation & Start-Up Guide

SYSTEMS for CATALYTIC FILTERS

Dual Column Dehydrating Breather Manual

HydroRite UVO 3. Troubleshooting Guide Residential. TSG-UVO158a. Copyright 2015 Hayward Industries Inc.

COPPER FREESTANDING TUB

J-PRO-22 Pump Proportional Feed Chlorinator Installation & Start-Up Guide

HTU-500 Ozone Generator

IMPORTANT SAFETY INFORMATION READ ALL...

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

CHAMPION PUMP OWNER S MANUAL

A2Z Ozone Inc. Clean Water and Pure Air for ALL around the world! Product Catalog 2014/15

Ozone plus UV Sanitation System Installation & Operations Manual

HALLMARK INDUSTRIES INC. HALLMARK INDUSTRIES INC. Safety WARNING WARNING. Must reset the voltage! Shallow Well Jet Pumps

L A signature series TA T N E RE O, A L L A T S IN

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

INSTALLATION MANUAL. PP1 Ozone System Designed for use within pool skimmer

HAYWARD POOL PRODUCTS, INC. 620 Division Street Elizabeth, NJ Tel:

Fleck 2510 SXT Catalox Installation & Start Up Guide

FILTRATION SYSTEM MODEL: FILTER - 5 MULTI-SHIFTER, INC. P.O. BOX CHARLOTTE, N.C TEL#: FAX#:

Ozone Systems. Installation & Operation Manual POE10 POE12. Corona Discharge Ozone Generators. ClearWater Tech, LLC. Integrated Ozone Systems

Professional Series. Chemical Feed System Model # US Patent No. 6,752,930 B2

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Owner s Manual. Models: Powered by S2Q-OZ, S2Q-OZ/2, S8Q-OZ, S8Q- OZ/ _RevJ

AIR MASSAGE KIT INSTALLATION INSTRUCTIONS

Spa Control System OWNER S MANUAL

Quick Start Guide. For product manuals and further installation / operation procedures visit

SMF PUMP OWNER S MANUAL

Transcription:

PZ2 Series Manual PROZONE INTERNATIONAL, Inc. Ozone Water Purification Systems INSTALLATION GUIDE and OPERATION MANUAL Prozone PZ2 Series Ozone Generator Systems SAFETY READ AND FOLLOW ALL INSTRUCTIONS. IMPORTANT SAFETY INSTRUCTIONS 1. All applicable electrical codes must be followed during and after installation. All connections to be made by a qualified electrician. 2. Disconnect all power at the main circuit breaker before installing the PROZONE unit. 3. WARNING - To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all times. 4. DANGER - Risk of electric shock. 5. Replace damaged cord immediately. 6. Do not bury cord. 7. Connect only to a properly grounded, grounding type receptacle. 8. Install at least 5 feet from the inside wall of the pool using non-metallic plumbing. The ozone generator is to be located one foot above the maximum water level to prevent water from contacting electrical equipment. Install to provide drainage of compartment for electrical components. 9. A pressure wire connector is provided in the control box inside the unit to permit connection of a minimum No. 8 AWG (8.4 mm 2 ) solid copper bonding conductor between this point and any metal equipment, metal enclosures of electrical equipment, metal water pipe, or conduit within 5 feet (1.5 m) of the unit as needed to comply with local requirements. 10. Wear safety glasses when drilling and tapping holes for installation of unit. 11. WARNING: Short term inhalation of high concentrations of ozone and long term inhalation of low concentrations of ozone can cause serious harmful physiological effects. Do not inhale ozone gas produced by this device. 12. Turn off power at source breaker before servicing the unit. 13. SAVE THESE INSTRUCTIONS. TABLE OF CONTENTS Safety Instructions Introduction to Ozone Preparing for Installation Installation of PZ2 Series Ozonators Operation of PROZONE Prozone Operation Water Chemistry Troubleshooting Guide Installation Kit Inventory

INTRODUCTION TO OZONE Ozone (O 3 ) is generated by irradiating air or oxygen (O 2 ) with ultraviolet radiation. Ozone is a molecule of oxygen that is formed when three atoms of oxygen are bound together instead of the normal two atoms. The extra oxygen atom makes ozone the most powerful oxidizer and sanitizer readily available. Since ozone is unstable and quickly decomposes to normal oxygen under normal conditions, it cannot be shipped or stored. Therefore, it must be manufactured on site for immediate use. In normal air it lasts about an hour. In normal pool water it lasts just long enough to purify the water - less than 1 second. Although ozone is mainly thought of as a sanitizer, it acts primarily as an oxidizer in the pool environment. In a typical pool run on chlorine only, up to 90 percent of the chlorine may be used up in reactions unrelated to disinfection. The byproducts of these reactions are combined chlorines. Combined chlorines are the cause of eye irritation, odor, and the other unpleasant side effects of chlorination. When ozone is used, it oxidizes a large portion of the contaminants (usually referred to as bather load) which result in the formation of combined chlorines. The result is that more chlorine is available for disinfection and less chlorine is required to maintain the pool. Ozone also provides some disinfection, but an ozone residual cannot be established, so the use of chlorine or bromine is always recommended. PREPARING FOR INSTALLATION 1. Locate Model PZ2-1 or PZ2-2 Ozonators or the compressor unit for PZ2-4 and higher models so that dust, sand, debris, chemicals, or other foreign objects are not sucked into the compressor's intake fan or hose (if equipped with Noise Attenuator). 2. Check electrical system: 240VAC double switched per N.E.C. standards; 120VAC single switched. 3. Check for and correct all plumbing for leaks. 4. Check for Suction Line Check Valve. Equipment may draw if no check valve is present. 5. Balance the ph. 6. Backwash the filter. 7. Shock the pool with a non-lithium-based material. The use of Calcium Hypochlorite or Sodium Hypochlorite is recommended. NOTE: If the pool has a Diatomaceous Earth (DE) filter, a 3/4" ball valve must be installed between the pump and the input side of the Venturi Injector. INSTALLATION NOTE: The instructions in this document provide general installation guides. Consult your dealer for specific installation instructions. Additional information is available at www.prozoneint.com. Check system for any visible shipping damage. If damage has occurred, contact the delivery company and your dealer immediately. Before beginning installation, please turn to the Installation Kit Inventory Section and verify that all listed parts are on hand. Tools Needed: Cordless Power Drill, Screw Driver, Adjustable Wrench, Pliers, Wall Mount Screw Anchors, Knife

PZ2-1 and PZ2-2 with BYPASS VENTURI 1. Directly after pump and before filter, attach one 1-1/2 or 2 brass saddle clamp using attached screws. 2. After all existing equipment (including heater, chlorinator, etc), attach second 1-1/2 or 2 brass saddle clamp to return line using attached screws. 3. Drill a 1/2 hole in the pipe through the hole in the top of each saddle clamp. 4. Apply Teflon tape to threaded end of each 3/4 mpt x 3/4 hb fitting. 5. Screw 3/4 x 3/4 fitting snugly into top of each saddle clamp. 6. Cut a 6 (15cm) length (plus or minus 1 ) of 3/4 clear hose and connect one end to the 3/4 barb fitting on saddle clamp nearest to pump; secure with a clamp. 7. If the venturi injector is model V3, insert the INPUT end of injector into 6 length of hose. If Mazzie injector, make sure flow is away from saddle; secure with a clamp (an arrow on the side of injector indicates flow direction). 8. Insert opposite end of venturi injector into remaining length of 3/4 clear hose and secure with a clamp. 9. Attach loose end of 3/4 hose to the 3/4 barb fitting on the return line saddle clamp using screw-type clamp. 10. Apply Teflon tape to threads of the two 1/2 x 1/4 fittings and screw these two fittings into each end of the check valve. 11. Cut a 6 length of 1/4 hose and connect one end to the output side of the check valve (flow away from ozone generator) and other end to ozone fitting on injector; secure with clamps. If V3 injector attach hose to port 1 (port 2 should be capped.) 12. Mount the PZ2 ozone generator vertically on wall with compressor at lower end, using two holes in rain shield. Place system at or above water level. If unit must be mounted below water level, loop the hose so that at some point it is above water level (a solenoid control valve may be necessary). 13. Attach one end of the remaining length of 1/4 hose to the ozone generator and the other end to the inlet side of the check valve. Making sure flow is away from ozone generator, secure ends with clamps. 14. Slip the M09 Noise Attenuator onto the 1 fitting on the rear of the PZ2. (See item 1 above, Preparing for Installation. 15. Electrical Installation: System is 120 or 240 VAC, 50/60 HZ. Wire Prozone ozone generator system to circulation pump switch or timer. Prozone system and circulation pump should be started simultaneously. Use N.E.C. or local code grounding and installation procedures for swimming pool equipment. Note: If Diatemateous Earth filter, install a 3/4 ball valve in the 3/4 hose line to the input side of the venturi. PZ2-1 & PZ2-2 with DIRECT INJECTION NOTE: There must be at least four feet (1.2 m) of return line between the point where the ozone bubbles are injected and the pool. If there is not four feet of return available, a flexible loop can be added to the return line. 1. Attach a 1-1/2 or 2 saddle clamp to return line after heater and automatic floor sweep using the attached screws. 2. Drill four (4) 3/16 holes in the pipe through the center of the hole in the saddle clamp. 3. Apply Teflon tape to threads of the 3/4 x 1/2 bushing; screw the bushing snugly into the saddle clamp. 4. Apply Teflon tape to threads of one of the 1/2 x 1/4 fittings. 5. Screw this 1/2 x 1/4 fitting into the 3/4 x ½ bushing. 6. Apply Teflon tape to the threads of the other two 1/2 x 1/4 fittings. 7. Screw these two 1/2 x 1/4 fittings into each end of the check valve. 8. Cut a 6 (15cm) length (plus or minus 1 ) of 1/4 hose and slide it over the barb on the 1/2 x 1/4 fitting screwed into the 3/4 x ½ pushing. Secure hose with a clamp.

9. Attach the other end of the 6 length of 1/4 hose to the barb on the output side of the check valve; secure with a clamp. (Flow is marked on side of check valve with an arrow.) 10. Mount the PZ2 ozone generator vertically on wall with compressor at lower end, using two holes in rain shield. Place system at or above water level. If unit must be mounted below water level, loop the hose so that at some point it is above water level (a solenoid control valve may be necessary). (See item 1 above, Preparing for Installation.) 11. Attach the remaining length of 1/4 hose between check valve and ozone generator; secure with clamps. 12. Electrical Installation: System is 120 or 240 VAC, 50/60 HZ. Wire Prozone ozone generator system to circulation pump switch or timer. Prozone system and circulation pump should be activated simultaneously. Use N.E.C. or local code grounding and installation procedures for swimming pool equipment. PZ2-4, PZ2-6, AND PZ2-8 SERIES WITH BYPASS VENTURI 1. Directly after pump and before filter, attach a 3/4 x 1 hose barb fitting to the plumbing using other appropriate fittings (not provided). 2. After all existing equipment (including heater, chlorinator, etc.), attach another 3/4 x 1 hose barb fitting using appropriate fittings (not provided). 3. Cut a 6 (15cm) length (plus or minus 1 ) of 1 clear vinyl hose and connect to the barb on the 3/4 x 1 fitting installed nearest to pump; secure with a clamp. 4. Insert venturi injector into the other end of the 6 length of 1 hose making sure flow is away from the saddle, and secure with a clamp. Flow is marked on side of injector with an arrow. 5. Insert opposite end of injector into remaining length of 1 hose and secure with a clamp. 6. Attach loose end of 1 hose to second 3/4 x 1 fitting installed in step 2. 7. Apply Teflon tape to the threads of the two 1/2 x 3/8 fittings. 8. Screw these two ½ x 3/8 fittings into each end of the check valve. 9. Cut a 6 length of 3/8 braided hose and connect the check valve and venturi together; secure with clamps. 10. Mount the PZ2 ozone generator(s) vertically on wall using two holes in rain shield. Place system at or above water level. If unit must be mounted below water level, loop the hose so that at some point it is above water level (a solenoid control valve may be necessary). 11. Mount the compressor next to the ozone generator(s). (See item 1 above, Preparing for Installation.) 12. Cut a length of 3/8 braided hose long enough to reach between ozone generator and compressor. 13. Attach this length of hose to the ozone generator(s) and compressor; secure with clamps. 14. Attach one end of remaining 3/8 braided hose to the barb on the ozone generator and other end to the barb on the input side of the check valve. Making sure flow is away from ozone generator, secure ends with clamps. 15. Electrical Installation: System is 120 or 240 VAC, 50/60 HZ. Prozone system and circulation pump should be started simultaneously. Use N.E.C. or local code grounding and installation procedures for swimming pool equipment.

PZ2-4, PZ2-6, PZ2-8 WITH DIRECT INJECTION NOTE: There must be at least four feet (1.2m) of return line between the point where the ozone bubbles are injected and the pool. If there is not four feet of return available, a flexible loop can be added to the return line. 1. Apply Teflon tape to the threads of one of the 1/2 x 3/8 fittings and attach the fitting to the return line after the heater and other equipment using other appropriate fittings (not provided). 2. Cut a 6 (15cm) length (plus or minus 1 ) of 3/8 polybraid hose and slide it over the barb on this fitting. Secure hose with a clamp. 3. Apply Teflon tape to the threads of the other two ½ x 3/8 fittings. 4. Screw these two ½ x 3/8 fittings into each end of the check valve. 5. Attach the other end of the 6 length of 3/8 hose to the barb on the output side of the check valve; secure with a clamp. (Flow is marked on side of check valve with an arrow.) 6. Mount the PZ2 ozone generator(s) vertically on wall. Place system at or above water level. If unit must be mounted below water level, loop 3/8 hose so that at some point it is above water level (a solenoid control valve may be necessary). 7. Mount the compressor next to the ozone generator. (See item 1 above, Preparing for Installation.) 8. Cut a length of 3/8 hose long enough to connect the ozone generator and compressor together; secure with clamps. 9. Attach the remaining length of 3/8 hose between input side of check valve (flow away from ozone generator) and ozone generator; secure with clamps. 10. Electrical Installation: System is 120 or 240 VAC, 50/60 HZ. Wire Prozone ozone generator system to circulation pump switch or timer. Prozone system and circulation pump should be started simultaneously. Use N.E.C. or local code grounding and installation procedures for swimming pool equipment. OPERATION A. PROZONE PZ2 SERIES OZONE GENERATOR OPERATION The Prozone system works when air is drawn across a high-energy vacuum ultraviolet (VUV) lamp, converting some air to ozone. The ozone is introduced into the water either by direct injection or through a bypass venturi system. For direct injection, the venturi injector is inserted directly into the return line of the pool creating a suction (vacuum) that draws the ozone into the venturi as the water returns to the pool. The bypass venturi system takes water directly after the circulation pump (highest pressure point), bypasses part of the water flow past filters, heater, etc. through a venturi injector, through contact tubing and then returns the water back to the pool return line. A check valve is employed to prevent water backup in the event of system failure. The system should be run 6-8 hours per day for best effect. Run time may vary depending on usage. B. WATER CHEMISTRY Water chemistry must be maintained to assure proper performance of the Prozone ozonator system and existing pool or spa equipment. The following levels are recommended: ph - 7.2 to 7.6. Ozone is ph neutral and will not cause the ph value of the water to fluctuate. Sanitizers - A chlorine level of.5 ppm to 1 ppm is recommended. Shock - Non-lithium-based material such as Calcium Hypochlorite or Sodium Hypochlorite, etc.

The use of other chemicals is not usually required and they could cloud the pool water. TROUBLESHOOTING GUIDE PROBLEM PROBABLE CAUSE REMEDY No light from Prozone unit Loose wiring No power to unit Check all wiring connections Voltage compatibility No bubbles from injector or no evidence of ozone in pool Water in Ozone Generator Cloudy water; foamy water; scum Defective lamp or other internal component Excessive back pressure Leak in fitting Filter not working Check valve failure Water chemistry out of balance Total Dissolved Solids (TDS) level too high Filter not working Check power source Return unit to dealer Check for kinks or clogs in hose or plumbing Replace fitting Check filter Verify check valve in venturi is operating properly Check readings and balance accordingly Refer to dealer for proper water testing Clean or replace filter NOTE: Cloudy water may occur when the ozone generator is started. Filter and backwash as necessary. INSTALLATION KIT INVENTORY PZ2-1 & PZ2-2 SERIES WITH BYPASS VENTURI Tee, Saddle, 1-1/2 x 3/4 Fitting, 3/4 MPT x 3/4 HB 2 each Fitting, ½ MPT x 1/4 HB 2 each 2 each Injector, 3/4 HB 1 each Valve, Check, ½ 1 each Hose, Polybraid, 1/4 6 feet (1.82m) Hose, Clear Vinyl, 3/4 Clamp, Hose, Metal, 1.25 8 feet (2.4m) 4 each Clamp, Plastic, Black, 0.500 4 each

PZ2-1 & PZ2-2 SERIES WITH DIRECT INJECTION Tee, Saddle, 1-1/2 or 2 x 3/4 Fitting, ½ MPT x 1/4 HB Hose, Polybraid, 1/4 1 each Valve, Check, ½ 1 ea 3 each Fitting, 3/4 MPT x ½ FP Bushing 10 feet (3.05m) Clamp, Plastic, Black, 0.500 1 ea 4 ea PZ2-4, PZ2-6 & PZ2-8 SERIES WITH BYPASS VENTURI Injector, 1 MPT 1078 Fitting, 3/4 MPT x 1 HB Hose, Polybraid, 3/8 1 each Fitting, ½ MPT x 3/8 HB 2 each Fitting, 1 FPT x 1 HB 20 feet (6m) Hose, Clear Vinyl, 1 2 each 2 each 10 feet (3.05m) Compressor 1 each Valve, Check, ½ 1 each Clamp, Hose, Metal, 1.5 4 each Clamp, Plastic, Black, 0.60 30 each PZ2-4, PZ2-6, & PZ2-8 SERIES WITH DIRECT INJECTION Fitting, ½ MPT x 3/8 HB 3 each Valve, Check, ½ Compressor 1 each Hose, Polybraid, 3/8 Clamp, Plastic, Black, 0.620 10 each 1 each 10 feet (3.05m) Note: For pools with Diatomaceous Earth filter and Bypass Venturi installation, add 1 each Valve, Ball 3/4 fpt x fpt; 1 each Fitting, 3/4 mpt x 3/4 mpt; 1 each Fitting, 3/4 mpt x 3/4 hb.