INSTALLATION MANUAL. PP2 Ozone System (No Filter Cartridge) PP3 Ozone System (With Filter Cartridge) nspdevelopment.com

Similar documents
INSTALLATION MANUAL. PP1 Ozone System Designed for use within pool skimmer

INSTALLATION AND USERS GUIDE

A2Z Ozone, Inc. PRODUCT MANUAL

IMPORTANT SAFETY INSTRUCTIONS EC-AG1-25 EC-AG1, EC-AG2 SAVE THESE INSTRUCTIONS.

Ozone + UV Sanitation

MCD. Corona Discharge Ozone Generators MANUFACTURED BY Bullock Lane San Luis Obispo, CA

Next Generation Corona Discharge Auto Voltage Sensing Installation Manual

Owner s Manual Zodiac Pool Systems, Inc.

FOR THE RECORD. You should record the model and serial numbers, which can be found on the back of the unit, for future reference.

Clear Comfort Residential Pool & Spa Sanitization System Installation, Operations & Maintenance Manual

OZONE SYSTEM FOR IN-GROUND POOLS New and Existing

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

DEL AOP 25 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL

Installation Guide. Manufactured for Aero-Spa, LLC Web:

BioZone Scientific International contact information

OZONE SYSTEM FOR IN-GROUND POOLS UP TO 18,000 GALLONS

1, 2, & 4. Corona Discharge Ozone Generators INSTALLATION & OPERATION MANUAL. DEL Ozone SAN LUIS OBISPO, CA USA Fax:

OPERATORS MANUAL FOR Mi-T-M CORONA DISCHARGE OZONE GENERATORS

Use and Care Manual. Flammable Material Storage Refrigerator LRBFS06W1HC

Air Pump Up to 800 gallons

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

gamma pond Ultraviolet Sterilizers

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

Surge Protective Devices Installation, Operation and Maintenance Manual. LowProfile Series: 080 and 120

Operator s Manual. Model G32-S Model G32-E Disinfection Soak Stations

Power Conditioners User s Manual. For use with Standard Power Conditioners, Medical Power Conditioners and Ground Guard Power Conditioners

Mixing Degas Vessel (MDV) EC-1, EC-2, EC-4, Total Eclipse 2 or 4, and TrioPure-25 or TrioPure-50

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

FloorHeat Installation Manual

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

e Bath Fan with Light User s Guide

AquaStream. ½ HP Floating Fountain. Please Keep for Your Records. Model #AS05 6A, 120V/60Hz Owner s Manual UNIT IDENTIFICATION

2-in-1 Corded Stick Vacuum Cleaner

ion Genesis Pump Controller

Next Generation Corona Discharge Installation & Operation Manual

Spa Control System OWNER S MANUAL

MaxLite 4, 6, 8 & 9 LED Architectural & Commercial Downlights

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

Ultraviolet Systems UV-C 50 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL

e Bath Fan with Light User s Guide

ZO-400 & ZO Installation & Operations Manual

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

OWNE R S MA N UA L. Made in USA. September 2015

Xaact Spot. Xaact Hot Spot

Pressurized Filter Up to 1250 gallons

Ceiling Mount Air Purification System

e Heater/Exhaust Fan/Light User s Guide

MaxLite LED MICRO-T PANEL

EcoMaster - Residential Pools up to 40,000 Gallons

Use this product according to this instruction manual. Please keep this instruction manual for future reference. MODELS: ST-H15-B & ST-H30

Industrial Dehumidifier Operating Instructions. Model: VG 1500

OKB, OKD, & OKH Series

BACKUP BATTERY INSTALLATION INSTRUCTIONS

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

1.5 L Electric Kettle

MaxLite LED Round Pendant Highbay Series

INSTALLATION INSTRUCTIONS MODEL PA-250 AND PA-500 BOOSTER AMPLIFIER

MaxLite LED Vapor Tight Linear Fixture

100 Series Maxi Internal Filters

Installation & Maintenance Guide

Operation and warranty Manual

MaxLite LED High Bay Fixtures

Easy installation in both new construction and retrofit

IAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide

Installation Manual. Expansion Module 0100 Version 1.0 EXP HBX Control Systems Inc.

Use this product according to this instruction manual. Please keep this instruction manual for future reference.

(The chances are you re never going to read me) Owner s Manual. Model S10E.

Easy installation in both new construction and retrofit

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

aquamanta the experts in aquatic technology CH 025/050/100/ 150/200/300 NEW PHOTO Instruction Manual

PRECISION PRECISION. Installation and Operating Instructions FLOW. AUTOMATIC REGULATOR

Easy installation in both new construction and retrofit. ZB90C ZB110C X2 Multi-Speed Ventilation Fan INSTALLATION GUIDE

Owner s. 18 Misting MF18W. To view

e Bath Fan with Light User s Guide

INSTALLATION AND OPERATING INSTRUCTIONS. For Reliance Controls Emergency Power Transfer Switch Kit Model Number 30216BRK

SUPER CLEAN FILTER PUMP USER S MANUAL 29P414XX/29P415XX/29P416XX/29P417XX

Owner s Manual PRINTED IN CANADA 05/2009

PZ2 Series Manual. PROZONE INTERNATIONAL, Inc. Ozone Water Purification Systems. INSTALLATION GUIDE and OPERATION MANUAL. Prozone PZ2 Series

Earn Reward Points register your new

Ultra Lightweight Household & Commercial Vacuums

EcoMaster - Residential Pools up to 40,000 Gallons

BX Series. Installation, Operation, Maintenance Instructions & Spare Parts

OWNER S Manual PRINTED IN CANADA 10/2009

Because you re not like everyone else. MISTING FAN MF18W OWNER S MANUAL

Because you re not like everyone else. EVAPORATIVE COOLER EC220W OWNER S MANUAL

UNIVERSAL TEE STYLE Hydromassage Bath Heater INSTALLATION INSTRUCTIONS

SANI-VAC MODEL #750 WARNING! FOR YOUR SAFETY PLEASE READ INSTRUCTIONS BEFORE OPERATING TOOL. & WEAR EYE PROTECTION

Ella Gel Coat Walk In Tub E SERIES OWNER'S MANUAL

Henny Penny Island Warmer Model HMI-103 Model HMI-105 TECHNICAL MANUAL

TrueClean ToteCleaner

Owner s. Coolerr. comply. To view

SEISCO SUPERCHARGER EXTENDER/BOOSTER INSTALLATION GUIDE & OWNERS MANUAL

HC12W COOL MIST ULTRASONIC HUMIDIFIER OWNER S MANUAL. Read and save these instructions.

Table of Contents Important Safeguards 2 Introduction 3 Installation 4 Operation 5 Cleaning Pattern 5 Automatic Shutoff and Removal 6 Maintenance 6

Canister Vacuum. OWNER S MANUAL Models CV520HB/HR/HY 120V., 60Hz., 10 Amps

Next Generation Corona Discharge Next Generation Corona Discharge Nueva generación Corona de descarga

Safety Information. Continued on page 4

ARUBA SUN SERIES - LIGHTING SYSTEM USER MANUAL

MODEL HDM-4 AND HDM-6 PERFECT HOLD DELI CASE INSTALLATION/OPERATION MANUAL

1 HP Air Mover. Owner s Manual

Transcription:

INSTALLATION MANUAL PP2 Ozone System (No Filter Cartridge) PP3 Ozone System (With Filter Cartridge) IN DECK CIRCULATION/FILTRATION UNIT PERFECT POOL OZONE GENERATOR! NOTE TO INSTALLER: GIVE THIS MANUAL TO OWNER OPERATOR AFTER INSTALLATION 18 North Dollins Ave, Orlando, FL 32805 Tel/Fax: 855-996-6900 nspdevelopment.com

The Ozone Generator requires the use of a GFCI as the power source when wired 120V INSTALLATION MANUAL SAFETY PRECAUTIONS! IMPORTANT SAFETY INSTRUCTIONS When installing and using this electric equipment, basic safety precautions should always be followed including the following:! 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. READ AND FOLLOW ALL INSTRUCTIONS WARNING - Risk of Electric Shock. Connect only to a grounding type receptacle protected by a ground-fault circuit-interrupter (GFCI). Contact a qualified electrician if you cannot verify that the receptacle is protected by a GFCI. WARNING - To reduce the risk of injury, do not permit children to use this product unless they are closely suprevised at all times. WARNING - To prevent electrocution and/or death make sure power is off at the breaker. Do not bury cord. Locate cord to minimize abuse from lawn mowers, hedge trimmers and other equipment. WARNING - To reduce the risk of electric shock, replace damaged cord immediately. WARNING - To reduce the risk of electric shock, do not use extension cord to connect unit to electric supply; provice a properly located outlet. Avoid touching/installing the Perfect Pool Ozone Generator box during electric storms. Death or serious injury may result due to lightning surges through the system. Be sure to check local electrical code for grounding electrical boxes via the approved method (internal conduit ground,external box ground to grounding rod, Ground Fault Circuit Interupter or GFCI, etc.) Use approved conduit routed by approved methods to conduit fittings on the unit. Be sure the mounting surface is able to support the load of the controller. Use all mounting hoels to secure the unit. There are no customer servicable components inside the Perfect Pool Ozone Generator. Only qualified electricians should open the unit for installation. All connections should enter an approved conduit method. SAVE THESE INSTRUCTIONS ADDITIONAL PRECAUTIONS A. DIRECT INHALATION OF OZONE GAS FOR PROLONGED PERIODS CAN BE DETERIMENTIAL TO YOUR HEALTH B. This unit produces Ozone Gas, a highly agressive oxidizing agent. It is intended only to be used in pool/spa OUTDOOR environments. C. The Ozone Generator cannot be located within 5 ft of pool waters edge. D. This Ozone Generator must be installed in accordance to Article 680 of the NEC and local code requirements.

MOUNTING INSTRUCTIONS WARNING! DU E TO THE DESIRED WATER RESISTANT SEAL OF THE ENCLOSURE, DO NOT REMOVE ANY KNOCKOUTS UNLESS THAT HOLE WILL HAVE A CONDUIT INSTALLED. IF A KNOCKOUT IS ACCIDENTALLY REMOVED, STEPS MUST BE TAKEN TO RESEAL THE OPENEING OR THE PERFECT POOL OZONE GENERATOR WILL BE DAMAGED. MOUNTING PAD MOUNT 1. Place unit on a secure concrete pad. (see Fig.1) 2. Use the four (4) mounting holes to secure the unit to the pad or mounting surface. WALL MOUNT 1. Select a mounting location so that the bottom surface of the unit will be raised above the ground or placed on a secure concrete pad. (see Fig.2) 2. Remove cover and locate the four (4) mounting holes (Fig.2) to secure the unit to the pad or mounting surface. 3. After securing unit to the wall replace cover and secure with the cover screws. Perfect Pool Ozone Gen. Concrete Pad Perfect Pool Ozone Gen. Mounting Holes (4) two on each side Mounting Holes (4) (Remove Cover) Wall Pad Mount Fig. 1 Wall Moung Fig. 2

UNIT OVERVIEW ON / OFF Switch 120 VAC WHITE: NEUTRAL BLACK: LINE GREEN: GROUND EXTERIOR VIEW Mounting Holes (4 total) INTERIOR VIEW NOTE: Components may change as Unit model changes Switch 120VAC Power Ozone / Air Out to Filter Internal Wiring Schematic Pump Ballast Switch S Line In(Black) Neutral (White) Ground (Green)

IN DECK FILTER MODULE INSTALL INSTRUCTIONS There are 3 key installation points that must be adhered to for proper operation. 1. The In deck filter module must be installed at a level of where the pool water is equal to the bottom of the BLACK COUPLER. THIS IS THE MOST CRITICAL INSTALLATION POINT 2. Conduit must be run from the In Deck Filter module to the Generator assembly located at the equipment pad. Since time to time this conduit will have water/ moisture in it, it needs to be properly glued the entire length. 3. The Water Inlet (suction middle pipe on filter base) should be located as low in the pool wall as possible. The Water Return ( outside pipe on filter base) should be located as high as possible on pool interior wall. Pool Water Level should align with bottom of Black Filter Coupler THE MOST CRITICAL INSTALL POINT IS MAKING SURE THE POOL WATER LEVEL IS ALIGNED WITH THE BOTTOM OF THE BLACK COUPLER ON THE FILTER MODULE

IN DECK FILTER MODULE INSTALL INSTRUCTIONS THERE ARE 4 CONNECTION ON FILTER BASE 1. 1 1/2" Inlet fitting - this is located in the direct center of the Filter BAse 2. 1 1/2 Return fitting located on the extreme outside of filter base. 3 1 3. There are 2 1 fittings that are blocked off. They do not pass into the interior of filter base. These 1" glue fittings provide the ability to glue in 1" pipe to be used as support pipes for the filter module itself. 2 SECURING FILTER MODULE There are 4 TABS located in the center area of the Black Coupler or Collar. 2 of the are shown here. These TABS are to be used to secure the Filter Assembly to rebar used in the deck area. By securing the filter module to rebar you can also ensure that the POOL WATER LEVEL aligns with the bottom of the Black Coupler. 2 1 ADJUSTING TO DECK POUR HEIGHT The collar on the top of the Filter Module is not glued and can be raised and tilted to match deck level around pool area. POOL WATER LEVEL ALIGNMENT

1. 2. 3. 4. Run 1 conduit from In Deck Filter to equipment pad or wherever Generator is located. Make sure to use sweep fitting no 90 degree elbows should be used as replacement of tubing would be very difficult. Run Tube from In Deck Filter to Oxone Generator and attach to Check Valve located inside Ozone Generator. Attach tubing to Straight barb fitting contained in bag. Secure tubing to barb with enclosed hose clamp. 5. Push Slip fitting with barb/hose into filter receiver fitting on side wall. INSTALLATION MANUAL TUBING & DIFFUSER INSTALL INSTRUCTIONS 6. Thread in 90 degree fitting and attach diffuser and hose. Insert under Chlorine Cartridge "Birdcage" and into the Filter cartridge 1 1/2" pipe. Make sure the diffuser is pushed down towards bottom of pipe.

Service Instructions FILTER ASSEMBLY The cartridge filter and the diffuser itself will need cleaning from time to time. The cartridge filter is removed by the following steps. 1. Turn Ozone Generator off using on/off switch on unit 2. On the inside of the In Deck Filter module - remove the diffuser and 90 degree wall fitting. 3. 4. 5. Unscrew the red Chlorine Cartridge birdcage. If unit has chlorine cartridge attached - this must also be removed at this time. Now g ently pull the cartridge element from the body. Hose off unit debris is gone. Reverse steps for installation. Ozone Diffuser The Ozone Diffuser will last for many years since it is made of materials specifically designed for ozone gas utilization BUT it will become very visably "dirty" from all the materials the ozone gas is oxidizing from the water. The diffuser is at this initial oxidation point. The ozone diffuser will turn from its normal white to a dirty brown or in some cases even black. There can be also evidence of redish material which can be an indicator metal particulates in the pool water. This is usually only seen on pools that have been filled from well systems. The ozone diffuser can be cleaned by soaking in vinegar or lemon juice. These mild acids will remove oxodized debris from ozone diffuser surface. We recommend that you have 2 Ozone Diffusers on hand so that they can be simply exchanged during cleaning, allowing dirty diffuser to soak till clean. Also these can be cleaned with liquid Muratic Acid. This will quickly clean the Ozone Diffuser. PLEASE BE VERY CAREFUL IN THE USE OF THIS MATERIAL AS IT IS EXTREMELY HARMFUL. LIQUID MURATIC ACID IS USED TO ADJUST Ph IN SWIMMING POOLS.

Service Instructions OZONE BULB REPLACEMENT The Ozone Bulb assembly should be replaced every 36 months -EVEN IF IT IS STILL OPERATIONAL. The Ozone Bulb assemby has been made so that anyone can replace these easily and quickly. 1. 2. 3. 4. Turn off circuit breaker that supplies power to the Ozone Generator. Disconnect the 4 wire connector so that you have 2 halves. Remove the hose from each end of the ozone bulb assembly. Final step is to push down on the middle of each clamp until they clamps union comes apart. You will have to do each clamp individually. The Ozone Bulb assembly is now removeable from can assembly. 5. Insert new ozone bulb assembly and reinstall going from steps 4 to 1. TROUBLESHOOTING GUIDELINES There can be only 3 areas to check if you think your Perfect Pool PP2 or PP3 is not operating correctly: The Ozone Generator air pump (1) - the ozone bulb assembly (2) or the Ozone Diffuser In most all cases utilizing a small vial of Phenol Red dye (#2) available at any pool store or store selling pool chemicals. Pheno Red is used to test swimming pool Ph. 1. 2. 3. 4. The first thing to check is to ensure that power is going to the Ozone Generator unit. To check for proper operation off these units - open lid assembly and pour in Phenol Red solution. If unit is operating correctly - you will see a PURPLE dye coming from the Perfect Pool return wall fitting in pool. This verify's that the air pump is working - air hose is connected and clear - diffuser is clean enough for bubble operation AND that the ozone bulb is still prodoucing ozone as it's oxidized the Phenol Red to purple. If Phenol Red enters pool still RED in color this is an indication that the Ozone Bulb needs replacing - replace per instruction and rerun Phenol Red test to verify proper operation. 5. Upon opening of In Deck Filter assembly and there is no bubbles being generated then there check to ensure power is on - air pump is operating and air tubing is still connected between Ozone generator and Filter. If not identify where problem is and repair. Contact Customer Service for additional information. 6. Always check Ozone Diffuser & Filter anytime there is low flow rate coming back into pool. Clean as neccessary to achieve correct flow rate.

PRODUCT REGISTRATION 3 Ways to Register your product: 1. Complete this form on-line and email to: CS@nspdevelopment.com 2. Print the form out and fax to: 1.855.996.6900 3. Mail the form to: NSP Development 18 North Dollins Avenue, Orlando, Florida 32805 NAME: ADDRESS: CITY: STATE: ZIP CODE: EMAIL: MODEL: PP-1 OZONE GENERATOR PP-2 IN-DECK OZONATION MODULE + OZONE GENERATOR PP-3 IN-DECK OZONATION & FILTRATION MODULE + OZONE GENERATOR SERIAL NO. : NSP Development will ship you 1 FREE Ozone Diffuser upon the registration of your Perfect Pool unit. This will allow for instant ozone diffuser swap outs when cleaning is necessary without have to wait. Thank you again for your Perfect Pool purchase and welcome to the best pool water possible. NSP Development 18 North Dollins Avenue, Orlando, Florida 32805 Phone:1.855.996.6900 Fax:1.855.996.6900 NSPdevelopment.com

LIMITED WARRANTY NSP Development (herein referred to as the Company ), warranties its products, to be free from defects in material and/or workmanship, under normal condition, use and service, for a period of ONE(1) year from the date of sale for use. This specific warranty is for parts only and specifically excludes all labor charges associated with warranty items. TERMS AND CONDITIONS: This warranty only applies when the Company s products are properly wired and installed together as a system; and operated within the electrical values shown on the Company s specification sheets; used designed and approved for the application and environmental conditions (temperature, humidity) within the normal specified operating range of the system. This warranty does not apply to any abnormal use in violation of any applicable standard, code or instructions for use in installations including those contained in the latest National Electrical Code (NEC), the Standards for Safety of Underwriters Laboratory, Inc. (UL), Standards for the American National Standards Institute (ANSI), in Canada, the Canadian Standards Association ( CSA ), Europe (CE), Australia (C-Tick). This warranty will not apply in the event of conditions demonstrating abnormal use or stress, including under/over voltage conditions, excessive switching cycles, alterations, accident, theft, misuse, abuse and damaged caused by negligent installation, improper maintenance or where adequate care has not been taken to prevent damage to the system. Replacement of the Company s product components with any other manufacturers will void the entire warranty. WARRANTY SERVICE CLAIMS: The Company must issue a Return Material Authorization (RMA) number for all requests for warranty review. To expedite service, please contact the Company s Customer Representative where you purchased the product. If you are unsure whether a situation exists that is covered by this warranty, please contact the Company s customer service department from the company or division where you purchased the product for assistance. In the event of a defect in material or workmanship during the warranty period, the Company will repair or replace (at its own discretion) its products under the conditions of the warranty. A complete list of the Company s brands and their warranty service contact information can be found at the end the warranty. RETURN OF DEFECTIVE PRODUCT: After contacting the proper company or division and receiving the RMA#, the purchaser / user shall promptly return the product after receiving instructions regarding if, when and where to ship product. Product must be returned within 30 days of receiving RMA#. Shipping box must be clearly marked with RMA#. Failure to follow this procedure shall void this warranty. The company will cover expenses for material but will not cover shipping costs. Products returned without an RMA# will be refused and returned to sender at the senders expense. REPLACEMENT OF PRODUCT, LIMITS OF LIABILITY: The foregoing shall constitute the exclusive remedy of the purchaser and the sole liability of NSP Development regarding its products and component warranty. NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IS MADE OR IS TO BE IMPLIED. In no event shall NSP Development be liable for any other costs or damages including labor charges, lost profits or revenues, incidental, special or consequential damages. The Company reserves the right to examine all failed products and components to determine the cause of failure and patterns of usage and reserves the right to be the sole judge as to whether any product or component is defective and covered under this warranty. THIS WARRANTY IS ONLY TO THE ORIGNAL PURCHASER OF PRODUCT AND DOES NOT TRANSFER. 18 North Dollins Ave, Orlando, Florida Tel/Fax: 855-996-6900 nspdevelopment.com 7.2015