Model 9001EXP Alarm. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

Similar documents
Model 9001, Alarm

Model 9001, Alarm

Model Combination Shower Eye/Face Wash

Model /8300CRP-8309CRP Shower & Eye/Face Wash

Model 8330 Stainless Steel Combination Shower Eye/Face Wash

Model /8320CRP Shower and Eye/Face Wash

Model TWBS.EW.H Tempered Water Blending System

Model 8356WCSM Pull-Down Shower Eye/Face Wash

Model 7656WCC Eye/face Wash

Model 8300FP Freeze Resistant Combination Shower Eye/Face Wash

Model 8356WCC Pull-Down Shower Eye/Face Wash

Model 9201EFE Tempered Water Blending System

Model 9201EW Tempered Water Blending System

Model NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

Model TWBS.SHE Tempered Water Blending System

Model 7500EB Portable Eyewash with Heater

Model 1011/1011HPS Drinking Fountain

Model 7501/7501T/7501TH/7501T240/7501T240H Portable Eyewash/Portable Eyewash with Heater

Model 7603BL/7603BL240 Heated Blanket for 7603 Portable Eyewash

Model 8730 INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. Outdoor Shower and Eyewash System General Area Classification & Class I Division 2

Model H1011.8/H1011.8HPS Water Cooler

Model 1900 Retrofit Bottle Filler

Model 7611 Eye/Face Wash

Model 8780 INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. Tempering Skid General Area Classification & Class I Division 2. No.

INSTALLATION & TESTING MANUAL

Model 7603/7603T/7603T240 Portable Eyewash / Portable Eyewash with Heater

3121FR Pedestal Mounted Drinking Fountain

H Barrier-Free Wall Mounted Electric Drinking Fountain

INSTALLATION & TESTING MANUAL

H Barrier-Free Wall Mounted Electric Drinking Fountain

H1011.8HPS Barrier-Free Wall Mounted Electric Drinking Fountain

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

ADA Compliant Freeze-Resistant Wall-Mount Fountain and Bottle Filler

ADA Compliant Freeze-Resistant Wall-Mount Fountain and Bottle Filler

Static Pressure Alarm For Hazardous Location Fume Hoods

SEISCO SUPERCHARGER EXTENDER/BOOSTER INSTALLATION GUIDE & OWNERS MANUAL

Model 1920/1920HPS/1920W Bottle Filler

Installation S19-324D1. Class I, Division 1, Groups C & D Explosion Proof. Emergency Signaling System

ADA Compliant Wall-Mount Fountain and Bottle Filler

Hawkins 44 in Ceiling Fan Owner s Manual. Hawkins Ventilador de Techo de 1,12 m Manual del Propietario

Installation Manual. Models 99168, 99169, 99170

Roanoke 48 in Ceiling Fan Owner s Manual. Roanoke Ventilador de Techo de 1,22 m Manual del Propietario

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

Installation. S19-320A (6' cable) S19-320D (12' cable) Flow Switch Alarm System. Table of Contents

DISCONTINUED. Installation. S19-320A (6' cable) S19-320D (12' cable) Flow Switch Alarm System. Table of Contents

Bentley II 13 in Ceiling Fan Owner s Manual. Bentley II Ventilador de Techo de 33 cm Manual del Propietario

Laing Thermotech. Autocirc The Instant Hot Water Pump Models E1-BCANCT1W-06 and E1-BCANRT1W. Installation & Operating Manual

model1117l with1920 ADA Compliant Dual Wall-Mount Fountain and Bottle Filler FEATURES & BENEFITS MODEL CHOICES OPTIONS SPECIFICATIONS

Installation, Operation and Maintenance Guide G3600 Series Thermostatic Mixing Valves

! WARNING. Before using product, read and understand instructions.

OCH-SSE series Direct Wired Units Indoor * and Outdoor Comfort Heaters

FOSTORIA INDUSTRIES, INC North Main Street Fostoria, OH Phone: Fax:

Installation Instructions for 116EXMLED Series AdaptaBeacon LED Lights for Use in Hazardous Locations. Description. Installation WARNING

Lifetime Limited Warranty

OPERATIONS MAINTENANCE MANUAL

Lifetime Limited Warranty

e Bath Fan with Light User s Guide

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL AH1000, BH1000, AND EH1000 SERIES ANNUNCIATORS

36 & 48 E-Z Cone Fan. Installation & Operator s Instruction Manual (Direct Drive)

FLCH4R Garage and Utility Electric Heater

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES

Florentine IV 56 in Ceiling Fan Owner s Manual Florentine IV Ventilador de Techo de 1,42 m Manual del Propietario

VENTILATION FAN WITH LIGHT AND HEATER

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

Model AV1LED Audio-Visual LED Light Installation and Maintenance Manual

24 VAC SYSTEM CONTROL KIT Model: CK-91F and CK-91FG

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

MaxLite LED Round Pendant Highbay Series

ECCOTEMP. Point of Use Tankless Water Heaters EP-2.4 / EP-7.0. Installation and Operating Instruction Manual. Shop Online.

(3 plastic wire connectors,blade balancing kit, 2 extra mounting screws #10-32 for outlet box.)

Warnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4. Replacement Element Installation 5. Replacement Parts 5

Alnor AirGard 410HE Air Flow Monitor for Hazardous Environment Fume Hoods

Installation & Maintenance Instructions

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

Comfort Series Instant Hot Water System

e Bath Fan with Light User s Guide

Lifetime Limited Warranty

Lifetime Limited Warranty

Burgess 54" Ceiling Fan with Remote Control Owner s Manual

INSTALLATION INSTRUCTIONS

Electric Mini Tank Water Heaters ME10 ME25 ME40 ME60

TORRID MARINE YACHT QUALITY Since Owner s Manual

WARNING WARNING. Installation Instructions for 116DEXSTC-FJ AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations.

INSTRUCTION MANUAL MM-615E. Series FS1 High Sensitivity Liquid Flow Switch

G Series SAVE THESE INSTRUCTIONS. (Model B) Convector Heater for Hazardous Locations GENERAL! INSTALLATION

XT Series Thermostats

e Bath Fan with Light User s Guide

VENTILATION FAN. MFG Model : VFB80HLED2/VFB080C4L2 /VFB080C4LED2/ VFB100HLED2/VFB100C4LED1 READ AND SAVE THESE INSTRUCTIONS

INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE SERIES XL-32, XL-82

Larson by Hampton Bay

GAS MONITOR Model Model

SUPPLEMENTAL INSTRUCTION SHEET POL S2 POINT OBSTRUCTION LIGHT SINGLE WITH ALARM

M Series Fan Filter Units

OPERATION & INSTALLATION MANUAL

Installation, Operation and Maintenance Guide AP3900 Series Thermostatic Mixing Valves

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

Decorative Low Profile Integrated Kit

Transcription:

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424 E-mail: haws@hawsco.com website: www.hawsco.com Model 9001EXP Alarm No. 2080203(24) NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY HAWS warrants that this specific product is guaranteed against defective material or poor workmanship for a period of one year from date of shipment. HAWS liability under this warranty shall be discharged by furnishing without charge F.O.B. HAWS Factory any goods, or part thereof, which shall appear to the Company upon inspection to be of defective material or not of first class workmanship, provided that claim is made in writing to Haws within a reasonable period after receipt of the product. Where claims for defects are made, the defective part or parts shall be delivered to the Company, prepaid, for inspection. HAWS will not be liable for the cost of repairs, alterations or replacements, or for any expense connected therewith made by the owner or his agents, except upon written authority from HAWS, Sparks, Nevada. HAWS will not be liable for any damages caused by defective materials or poor workmanship, except for replacements, as provided above. Buyer agrees that Haws has made no other warranties either expressed or implied in addition to those above stated, except that of title with respect to any of the products or equipment sold hereunder and that HAWS shall not be liable for general, special, or consequential damages claimed to arise under the contract of sale. The emergency equipment manufactured by HAWS is warranted to function if installation and maintenance instructions provided are adhered to. The units also must be used for the purpose for which they were intended. This product is intended to supplement first-aid treatment. Due to widely varying conditions, Haws cannot guarantee that the use of this emergency equipment will prevent serious injury or the aggravation of existing or prior injuries. NO OTHER WARRANTIES EXPRESSED OR IMPLIED ARE AUTHORIZED, PROVIDED OR GIVEN BY HAWS. SHOULD YOU EXPERIENCE DIFFICULTY WITH THE INSTALLATION OF THIS MODEL PLEASE CALL: TECHNICAL SUPPORT: 1-800-766-5612 FOR CUSTOMER SERVICE: 1-888-640-4297 08/17 Model 9001EXP Page 1 of 6

RECOMMENDED TOOLS: Pipe joint sealant, screwdriver, pipe wrench, 14 AWG wire, ¾ conduit and basic electricians tools for power connection. LOCATION OF UNIT: The Model 9001EXP Alarm may be mounted directly to the upper stand pipe of a safety shower or wall mounted next to a shower or eyewash. The alarm should be clearly visible from several directions. ELECTRICAL SUPPLY: 120 VAC 50/60 HZ, 20 Watts average power consumption. Suitable for use in Class I, Division 2, Group B, C, D areas; Temperature rating T2C (230 C) with 60 Watt lamp /T2A (280 C) with 100 Watt lamp. Unit supplied with 60 Watt lamp. WARNING: Power shall be supplied by a dedicated circuit through a 10 AMP maximum breaker or fuse and should not supply any power to any other devices. WATER SUPPLY: The flow switch requires a minimum of 2.4 GPM to activate. Mount flow switch in supply line with flow in horizontal direction and switch stem extending vertically from tee. Mount switch with at least 6 of straight pipe on both sides to minimize turbulence in switch. PROBLEM 1. Alarm horn and light do not operate. 2. Horn sounds but light does not flash. TROUBLESHOOTING REPAIR CHECKLIST 1a. Check incoming circuit for power and power from flow switch. b. Check that the direction of water flow corresponds to the arrow on the flow switch body. c. Check that water flow is sufficient. d. Check all electrical connections for security, including those in alarm base. e. Faulty flow switch. Replace entire switch assembly. f. Faulty flasher module in alarm. Replace flasher module. 2a. Only replace lamp with Haws P/N 0003225505. (See sheet 2 of installation drawing) b. Should replacement lamp also fail to operate, replace flasher module. 3. Lamp replacement. 3a. Remove the guard from the light fixture, and then unscrew the glass lens to replace the lamp. Only replace lamp with Haws P/N 0003225505. (See sheet 2 of installation drawing) 4. Alarm stays on. 4a. Check wiring connections. b. Disconnect flow switch wires and test for continuity. 08/17 Model 9001EXP Page 2 of 6

INSTALLATION PROCEDURE *WARNING: EXPLOSION HAZARD SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS 1, DIVISION 2 STEP 1: STEP 2: STEP 3: Choose a location for mounting the flow switch in the water supply line. The inlet and outlet ports of the flow switch must be a minimum of 6 inches from any tees or elbows in the water supply line. See attached installation drawing. Mount the flow switch assembly in the water supply line. The switch body must be in the vertical position with the water pipe horizontal. The water flow must be in the direction marked by the arrow on the flow switch body. Use pipe sealing compound on all water pipe connections. Choose a location for mounting the alarm assembly. The alarm housing should be positioned along a vertical axis at least 7 feet above ground for best visibility. The alarm may be mounted directly to a water pipe using the supplied bracket, U-bolt, washers and nuts. The alarm can also be bolted to a flat surface such as a wall, using the supplied wall-mounting bracket with appropriate fasteners (not supplied). STEP 4: Connect power to terminal blocks 1 and 2 for the alarm. Terminal blocks 5 and 6 may be used for remote alarm actuation. Refer to wiring diagram on installation drawing. NOTICE: ALL POWER CONNECTIONS MUST BE MADE ACCORDING TO NEC CODE USING TYPE 4 AND CLASS 1 DIVISION 2 COMPLIANT EQUIPMENT. OPERATION AND TEST INSTRUCTIONS Test weekly. Instruct all employees in the use of emergency showers and eyewashes. STEP 1: STEP 2: STEP 3: Apply power to the alarm branch circuit. The alarm should remain OFF. Open the shower or eyewash flow valve. The alarm should sound and the light should flash shortly after water flows from the system. Shut off the flow valve. The light and horn should turn off. For more information about Haws products see our website: www.hawsco.com 2017 Haws Corporation All Rights Reserved HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation. 08/17 Model 9001EXP Page 3 of 6

THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE. PARTS BREAKDOWN 0003225505 (LAMP ONLY *) 0210000283 HORN SP154DPDT FLOW SWITCH * TEMPERATURE CODE IS AFFECTED BY LAMP WATTAGE. 60 WATT LAMP YIELDS T2C (230 DEG C), 150 WATT YIELDS T2 (300 DEG C). SUPPLIED LAMP IS 8 WATT LED. 1455 KLEPPE LANE SPARKS, NEVADA 89431 (775) 359-4712 FAX (755) 359-7424 E-MAIL: HAWS@HAWSCO.COM WEBSITE: WWW.HAWSCO.COM ECN NO. REVISED PER BY MODEL(S) PART NUMBER ECN: 5197 GC 0002080203 DRAWN DATE CHKD 9001EXP ALARM DRAWING NO. REV CLF 3/17/93 APPROVED DATE A 24 FV 09/25/17 SCALE: 1:1 DRAWING TYPE: PARTS BREAKDOWN SIZE: A SHEET 1 OF 1 WHEN ORDERING PARTS PLEASE SPECIFY MODEL NUMBER. C 2017 Haws Corporation - All Rights Reserved R HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation. PAGE 4 of 6

THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE. NOTES: 1. AUDIBLE AND VISIBLE ALARM ACTIVATED WHEN SHOWER OR EYEWASH IS IN USE. FLASHING LIGHT 2. 120VAC SUPPLY VOLTAGE REQUIRED, APPROXIMATELY 100VA ALL ELECTRICAL HOOKUPS TO MAIN JUNCTION BOX. PAGE 5 of 6 4 SEE SHEET 2 FOR LAMP REPLACEMENT 3. SYSTEM CERTIFIED AS SUITABLE FOR CLASS I, DIV. 2 GROUPS B, C, D LOCATION INSTALLATION. INSTALLER MUST USE THREAD SEALANT, SUCH AS APPLETON TLC3, RECOMMENDED FOR USE IN HAZARDOUS LOCATIONS ON ALL ELECTRICAL NPT CONNECTIONS. FLOW SWITCH CAUTION: DO NOT DISASSEMBLE OR ROTATE THIS ASSEMBLY AT ANY JOINT AS DAMAGE WILL OCCUR C 1-1/4" UNIONS (BY OTHERS RECOMMENDED) MAIN JUNCTION BOX (120 VAC INCOMING SUPPLY BY OTHERS) (ON FAR SIDE) CONDUIT ENTRY FOR CUSTOMER ELECTRICAL HOOK UP 1-1/4 IPS WATER SUPPLY 6"MIN. 152mm STRAIGHT FLEX CONDUIT "Y" SEAL LOCATED AT HUB ON JUNCTION BOX NOTE FLOW DIRECTION ARROW 6"MIN. 152mm STRAIGHT (3-5/8") SWITCH MUST BE MOUNTED IN HORIZONTAL POSITION 2017 (13") HORN MAX PIPE SIZE Ø1 3/4" 2(x2) 1 GROUND (2X) 5 6 (110 VOLT) 10 (PINK) SHOWER 9 (RED) 8 (GRN) (PURPLE) (NEUTRAL) FS COM 1 NO 1 NC 1 COM 2 NO 2 (BLK) (WHT) NC 2 ECN NO. REVISED PER BY: ECN: 5197 GC DRAWN: DATE: CHK'D.: CJL 06/91 APPROVED: DATE: FV 09/25/17 (CONTINUED ON SHEET 2) (WHT) 6 4(x2) (BLK) (RED) MODEL(S) FLSH (BLK) COMPONENT DESIGNATION: - TERMINAL BLOCK FLSH - FLASHER RELAY LT1 - RED LIGHT FS - FLOW SWITCH AH - ALARM HORN 9001EXP ALARM 3 4 LT1 2 (BLK) (WHT) G 5 AH 3 1455 KLEPPE LANE SPARKS, NEVADA 89431 (775) 359-4712 FAX (755) 359-7424 E-MAIL: HAWS@HAWSCO.COM WEBSITE: WWW.HAWSCO.COM PART NUMBER DRAWING NO. SCALE: 1:1 DRAWING TYPE: INSTALLATION SIZE: A SHEET 1 OF 2 R Haws Corporation - All Rights Reserved. HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation. 7 0002080203.D REV 09648A00 24

THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE. NOTES: (CONTINUED FROM SHEET 1) 4 LIGHT REPLACEMENT INSTRUCTIONS: PENDANT MOUNT 1) REMOVE GUARD AND GLOBE: FIRST LOOSEN SET SCREW (LOCATED ON GUARD WHERE SHOWN). NEXT, ROTATE GUARD COUNTER CLOCKWISE UNTIL GUARD IS FREE. FINALLY ROTATE GLOBE COUNTER CLOCKWISE UNTIL GLOBE IS FREE AND LAMP IS EXPOSED. LAMP PAGE 6 of 6 2) ONLY REPLACE LAMP WITH HAWS P/N 0003225505. WARNING - EXPLOSION HAZARD - SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS 1, DIVISION 2. GLOBE 3) REPLACE GUARD AND GLOBE: ROTATE GLOBE CLOCKWISE ONTO THREADS UNTIL SEALED AGAINST GASKET. NEXT, ROTATE GUARD CLOCKWISE ONTO THREADS UNTIL TIGHT. FINALLY TIGHTEN SET SCREW. GUARD SET SCREW C 2017 ECN NO. REVISED PER BY: ECN: 5197 JP DRAWN: DATE: CHK'D.: HM 08/12/09 APPROVED: DATE: FV 09/25/17 MODEL(S) 9001EXP ALARM 1455 KLEPPE LANE SPARKS, NEVADA 89431 (775) 359-4712 FAX (755) 359-7424 E-MAIL: HAWS@HAWSCO.COM WEBSITE: WWW.HAWSCO.COM PART NUMBER DRAWING NO. SCALE: 1:1 DRAWING TYPE: INSTALLATION SIZE: A SHEET 2 OF 2 R Haws Corporation - All Rights Reserved. HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation. 0002080203.D REV 09468A00 24