Pilot devices Stacklights Signal beacons

Similar documents
Half-Dome. the Design-Tower. Compact

New Beacon Series T & U

signaling solutions from auer signal

Auer - Signal tower ECO Ø70 mm modular

Attention-grabbing performance from two new stacklights

Optical-Audible Signal Devices

signaling solutions visual signaling signal towers Audible signaling

Series M22 Signaling Beacons and Alarms

Bulletin 855T 70 mm Control Tower Stack Lights

Sonos-SB Siren/Beacon

Signaling Devices. Acoustic Signaling Devices 298. Optical Signaling Devices 309. Bosch Security Systems B.V.

The Signal Is Clear TM

Signaling Solutions for Alarm, Warning, and Indication

Mounting Kits. LWMB2 6" 6 3 /8" 5 7 /8" 2.6 lbs lbs. LCMB2 6" 5" 5 3 /4 2.3 lbs. 2.5 lbs.

Protective Cabinet STI-7534, STI-7535 and STI-7535AED

Yodalarm. Sounders. Pg Y03 Y04/YL4 Y05/YL5 Y08/YL8/Y08 SUPER/ YL8 SUPER V4 V6/Y06/YL6 Carillon

Bulb Overview DESCRIPTION PART NO. TOTAL VOLTAGE FOR USE WITH: LENGTH(mm) Free-standing Beacons Accessories. Optical Signal Devices

5 yr. Vitalite Rotating Warning Light. Models 121 and 121A LIGHT DUTY VEHICULAR LIGHT

Star Headlight & Lantern Co., Inc. Company Presentation. Leader in Warning, Emergency Lighting and Signaling Products

MODEL AV2-C1D1M Hazardous Duty Class I. Div 1, Multitone Alarm Station

Security - Warning Devices Audible & Visual

ELECTRONIC SOUNDER STROBE Model : AVD-C407

Industrial Horn & LED Strobe Warning System - 12V DC - Weatherproof - NEMA 4X - Class 1 Beacon

About Tomar Audible Alarms 1000 & 1100 Power Alarm WEP Explosion Proof Power Alarm Siren

FIRE AND SAFETY. Manual Call Points p15-1 Magnetic Door Holders p15-3 Detection Cables p15-4 Portable Signals p15-7 Solar Powered Signals p

VISUAL AND AUDIBLE SIGNALLING DEVICES

Industrial Signalling

XVUC29 Ø60mm LED unit - steady/flash/rotate, multicolor unit, IP65, 24VAC/DC

AUTOMAX devices for the automation industry

Stacklights E26 Series

LED Ultrastar. trobe beacons

105 Series AdaptaBeacon Adverse Location Signal Type 4X, Marine Rated, Div. 2, UL 1971 Listed Model

DETCON MODEL AV1/AV2-C1D2M Hazardous Duty Class I. Div 2, Multitone Alarm Station

DETCON MODEL AV2-C1D2C Hazardous Duty Class I. Div 2, Continuous Tone Alarm Station

MODEL KP-200 VANDAL RESISTANT & WEATHERPROOF FLUSH MOUNT DIGITAL KEYPAD DESIGNED FOR ACCESS CONTROL APPLICATIONS

Elite. GJD022 /GJD023 35m External PIR. Multi Beam Lens Data

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

Celebrating YEARS Manufacturers of Visual & Audible Signalling Devices. NEW Exd

WE PROTECT HAZARDOUS ENVIRONMENTS EXPLOSION-PROOF AND HAZARDOUS LOCATION VISUAL & AUDIBLE SIGNALING PRODUCTS

Contents. Security. Page

Vibratone Horns. Models 350 and 450

Model VPS Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass

K100A Insertion Probe Thermometer

FlexSQUARE Square shaped beacons

Smoke and Fire Curtains

I P. Tough Starters for Tough Environments. Explosion Proof Starter. Ready to Install, Completely Wired and Assembled

Fire & Industrial Signalling

TECHNICAL INFORMATION Touchtronic Clothes Dryers

Bulletin 140G Molded Case Circuit Breakers Product Selection 225 A, I-Frame

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

AUDIBLE SIGNALIZATION

4040 FM 535 F :

Touchpoint Plus. A whole new control experience

ACP10 & ACP50 Security Systems

VIMPEX BS Evacuation. Fire Alarms EN Banshee. Beacons. FlashDome. Electronic Sounders. Audible Alarm

Combustible Gas and Hydrogen Sulfide Beacon 200 Rig Monitor Operator s Manual

Dräger Polytron 5700 IR Detection of flammable gases and vapours

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

Genesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet

IT AFEM. Table of Contents. Error! Table not allowed in footnote, endnote, header, footer, comment, or text box.

Model VPS + VPU Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass with Automatic Power Transfer Switch

C1D1 Explosion Proof Horn - Industrial Siren - Programmable Timer - NEMA 4X - Weatherproof

Vigilant LED Based Obstruction Lights

Owner s Guide and Installation Manual

Conventional Audible Visual Range

MODEL LP3 INSTALLATION AND SERVICE INSTRUCTIONS FOR STREAMLINE LP3 STROBE LIGHTS

INFRARED MODULATED BARRIERS

Sounder AX03, AX05. Loud signalling device with 32 different signals. Application. Design. Signalling devices with good directivity

Smarter Signaling AUDIBLE/VISUAL SIGNALS

Control and Annunciator Panels. Compact systems of signalling and control

Tempco s process controllers provide integrated solutions to manage your thermal loop system.

EUROPE S LEADER IN SIGNALLING. EvoSIGNAL. The quick and easy way to create the perfect signalling solution.

Two-Channel Gas Controller

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

OPTICAL TURNSTILE SYSTEM

AP200 SERIES INTELLIGENT ALARM DEVICES

TABLE OF CONTENTS. 1. Intelligent Light 1.1 Intelligent Corridor Light 1.2 Intelligent Down Light

Safe & hazardous area. Industrial products catalogue

Conceal-Alarm Series FA100 & FA900. ETL listed to UL standards UL1971, UL1480, UL464

Sprecher + Schuh Motor Control and Protection Products

AlarmLine Addressable Linear Heat Detector

New Products 2012 / 2013

DIGITAL ALARM UNIT Model ALU-AP

AP200 SERIES INTELLIGENT ALARM DEVICES

PolyGard 2-channel Gas Controller MGC-03

TECHNICAL GUIDE FOR BLUE MINI-VEGA LIGHTBAR WITH MULTI-TONE SIREN SUMMARY 1. DESCRIPTIONS... 2

Product overview. Louder & Brighter since 1910.

Multi Tone Alarm Sounders A

Dräger PointGard 2100 Detection of toxic gases and vapours

INSTRUCTION & SERVICE MANUAL

Model AV1LED Audio-Visual LED Light Installation and Maintenance Manual

VA301C CONTROLLER WITH BACnet OPTION

Informer15 Speaker. Description, Specifications, Installation, Operation, and Service Manual. Model I-IP15 IP-Enabled Indoor/Outdoor Speaker

Fiber Distribution Box

QUALITY. Total Information Technology

Industrial Signalling. Signalling Solutions

From.

Vibratone Horns. Models 350 and 450

LA5579 Wireless Siren Operation Manual

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

Transcription:

Pilot devices Fast mounting of signal elements using bayonet fixing Easy changing of bulbs for each module without tools Up to 10 light elements possible with 2-sided mounting bracket Flexibility of signal element combination Flashing light elements can be mounted in each module Up to 5 flashing light elements possible High protection rating optical and audible signal elements with IP 54, UL Type 2, 5 LED elements for long life Vandal-proof construction withstands every mechanical and natural challenge both indoors and outdoors High protection rating IP 65, UL Type 2, 5, NEMA 4X Cap consists of high impact polycarbonate (up to 20 J). Bulb change via inside of control box Available with LED bulbs. Simple mounting with quick fix system Each module is equipped with bayonet mounting with an integral contact system. The modules are fastened together by aligning the corresponding white marks; with a gentle twist, they are locked into place. 3.1

Optical modules Selection Light element KL-401G KL-302R Permanent light, 12 240VAC/DC (Bulb not included) KL-401R KL-401G KL-401Y $ 36.00 KL-401L KL-401C Flashing light, 24VAC/DC (Bulb not included) KL-302R KL-302G KL-302Y 100.00 KL-302L KL-302C Strobe light, 24VDC KL-203R KL-203G KL-203Y 165.00 KL-203L KL-203C Flashing light, 115VAC/DC (Bulb not included) KL-312R KL-312G KL-312Y 100.00 KL-312L KL-312C Strobe light, 115VAC KL-113R KL-113G KL-113Y 155.00 KL-113L KL-113C Flashing light, 230VAC/DC (Bulb not included) KL-322R KL-322G KL-322Y 100.00 KL-322L KL-322C Strobe light, 230 VAC KL-123R KL-123G KL-123Y 155.00 KL-123L KL-123C LED permanent light, 24VAC/DC KL-305R KL-305G 135.00 KL-305Y LED flashing light, 24VAC/DC KL-306R KL-306G 140.00 KL-306Y LED rotating light, 24VAC/DC KL-307R KL-307G 140.00 KL-307Y LED element Bulbs for stacklight K (7W max) Bulb BA15d, 42mm 24V, 5W KLB24 115V, 5W KLB1 $ 8.00 230V, 5W KLB2 3.2

Accessories Audible modules KB-3101 KT-1001 Buzzer element: continuous pulse tone, 85dB 230VAC KB-1201 $ 115.00 24VAC/DC KB-3001 95.00 115VAC/DC KB-3101 115.00 Siren element: 8 different tones adjustable volume, 100dB 24VAC/DC KS-3004 145.00 115VAC/DC KS-1104 155.00 230VAC/DC KS-1204 155.00 Siren element: continuous tone, 108dB 24VDC KS-2002 100.00 Siren element: 7 different tones adjustable volume, 100dB 24VDC KS-2004 145.00 Terminal elements 1 For tube mounting KT-1001 For bracket or base KT-1002 $ 40.00 KA-1001 KA-1002 KA-1012 Special parts Catalog List Item number price Contact box Cable exit at side KA-1001 $ 23.00 Magnetic base KA-1002 65.00 Base with tube D=25mm L=110mm KA-1011 33.00 Base for tube D= 25mm, plastic KA-1012 15.00 D= 25mm, metal KA-1013 32.00 Tube D= 25mm L=250mm KA-1021 20.00 D= 25mm L=400mm KA-1022 27.00 Bracket 1-sided mounting KA-1031 2-sided mounting KA-1032 20.00 AS-Interface module 18.5 31.6 VAC/DC KASI-4101 18.5 31.6 VAC/DC (for external voltages) KASI-4102 $ 300.00 KA-1011 KA-1013 KA-1022 KA-1031 KA-1032 1 Each signal tower assembly must contain a terminal element. 3.3

Selection Light element KSB-40IY Permanent light, 12 240VAC/DC (Bulb not included) KSB-401R KSB-401G KSB-401Y $ 55.00 KSB-401L KSB-401C Strobe light, 24VDC KSB-203R KSB-203G KSB-203Y 180.00 KSB-203L KSB-203C Strobe light, 115 VAC KSB-113R KSB-113G KSB-113Y 155.00 KSB-113L KSB-113C Strobe light, 230 VAC KSB-123R KSB-123G KSB-123Y 155.00 KSB-123L KSB-123C LED Permanent light, 24 VAC/DC KSB-305R KSB-305G 190.00 KSB-305Y LED Flashing light, 24 VAC/DC KSB-306R KSB-306G 195.00 KSB-306Y LED Rotating light, 24 VAC/DC KSB-307R KSB-307G 195.00 KSB-307Y Bulbs for signal beacons (10W max) Bulb BA15d, 52mm 12V, 7W KSBB12 24V, 7W KSBB24 115V, 7W KSBB1 230V, 7W KSBB2 $ 8.00 3.4

Approximate dimensions 1 Contact box for cable exit at side Base for tube, plastic 54 15 Rubber seal 4.2 43 184 240 85 56 296 352 408 15 5.5 Contact box with magnetic base Base for tube, metal 46 32 Base with integrated tube Connection plan ø 25 110 ø 10.5 54 ø 5.5 ø Module Bracket 1-sided mounting Connection plan with AS Interface module U extern (-) U extern (+) 69 3 4 2 ASI (+) 1 0 5 Drilling plan for stacklights Bracket 2-sided mounting ASI (-) 54 1 All dimensions in millimeters. 3.5

Approximate dimensions 1 68 Drilling plan for signal beacons 39 7 64.5 16 3 32 22 ( 37) 75 Screw terminal M3 Pull relief 1 All dimensions in millimeters. 3.6