A series of technical features make this gas detector extremely versatile, reliable, accurate, and safe.

Similar documents
CHCO Double Gas Detector

GS920 Gas Detector with Earthquake-proof Device

HCF100 Refrigerant FREON R410A, R134a, R407C, R404A

Control Unit BX280 CONFORMITY EN EN EMC EN Isntallation and user Guide. Firmware Version 9.0

Portable Gas Detector RP110. User Guide. Explosive gas detection SEMICONDUCTOR sensor technology Intrinsically safe. Conformity EMC EN50270.

GS920 Gas Detector with Earthquake-proof Device

Gas Detector with Earthquake-proof Device GS920 - V 3

Gas Detection Probe SG895 ATEX

SGF 104 Oxygen Sensor

GAS LEAK DETECTORS FOR METHANE AND LPG P11 - P12

GS100M Gas Detector. Technical Specification

BX444-Mc Gas Detector

GAS LEAK DETECTORS FOR METHANE AND LPG P11 - P12

GL-CO-RFG Channel Gas Leak Alarm System

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

COSTER. Code Internal Alarm Pre-alarm Suitable sensor threshold threshold external sensor

GAS MONITOR Model Model

Electronic control unit for gas leak detection with 4 detection zones

TECHNICAL CATALOGUE GAS LEAK DETECTOR AND SOLENOID SAFETY VALVES

BX444-M Gas Detector. Features. Application. Operation

User manual and installation instruction Control for Fire Ventilation RV / RV 24-32

GS100M Gas Detection Controller

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

Operating Instructions. For. Alarm Control Module. Model SSR 500

2. General information Page Warnings Page Technical characteristics Page Installation Page Front panel Page 7

Gas leak detection system. for heating rooms and similar environments. Description. Sensor for methane gas IP44. Sensor for LPG gas IP44

COMBUSTIBLE GAS LEAK DETECTOR PEN

GS100M Gas Detector. Features. Application. Operation

Instruction Manual. Electronic gas and smoke detector GRM

USERS MANUAL FOR GAS BOILERS

Setup instructions. Honeywell GAS DETECTOR. Overview. Accessories The instruction x1 Plug dowel x2 Screw x2 Double-sided adhesive tape x2

Warranty Registration

BEP Marine Gas Detector FD-2

JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS

Light oil burners. One stage operation

USE AND INSTALLATION HANDBOOK

KAB Gas Alarm Operation Manual

NG-9B NATURAL GAS ALARM

GS300M Gas Detector. Features. Application. Operation

Instruction Manual WARNING

KSGD-01W/S SEMI CONDUCTOR STAND ALONE REFRIGERANT LEAK DETECTOR. Instructions for :- KSGD-01W/S Semi Conductor Standalone Refrigerant Leak Detector

Installation and Wiring 1.

Installation and Operating Manual MX 32 2 CHANNEL CONTROLLER. The Fixed Gas Detection Experts. Reference: NPM32GB Revision: B.1

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

Controllers. Instruction Manual WARNING

DRYTEK 1 - User Manual ELECTRICAL PANEL FOR 1 MOTOR WITH POWER FACTOR CONTROL

IMPORTANT INSTRUCTIONS

BEP Marine Gas Detector 600-GDRV

The device is not suitable for continuous operation, but only for short-time operation (note lifetime of battery).

MX 15. Installation and Operating. Manual SINGLE CHANNEL CONTROLLER. The Fixed Gas Detection Experts. Part Number: NPM15GB Revision: C.

USE AND INSTALLATION HANDBOOK

1 measurement signal input 4-20 ma for connection to an external gas sensor 5 freely programmable alarm switching points per measuring point

INSTALLATION AND MANINTENANCE INSTRUCTIONS

INSTRUCTION MANUAL T30 1MN0107 REV. 0. operates with ISO9001 certified quality system

Commercial and Light Industrial Fire Alarm Control Panel

READ AND SAVE THESE INSTRUCTIONS GENERAL SAFETY INFORMATION

Installation and Programming manual INSTALLATION MANUAL E PROGRAMMING INSTALLAZIONE PROGRAMMAZIONE

RK / RK Methane Detector Operator s Manual

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

Installation, Operating and Maintenance Manual

Macurco HD-11 Hydrogen Gas Detector

SERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS

G-TECTA Cellaguard Carbon Dioxide and Oxygen Fixed Monitors

FLAME AMPLIFIER MODULE 3001

Laboratory Airflow Monitors & Controls TYPE C STANDARD & NIGHT SETBACK LED & DIGITAL - VAV SYSTEMS

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector

Interrupted Ignition Series Oil Primary Control

RK/ RK Combustible Gas Detector Operator s Manual

KAE Gas Alarm Operation Manual

EXPLOSION-COUNTERACTING SYSTEM «UDAR-KB» Installation Guide

SENSIT HXG-2. Instruction Manual For use with combustible gases Gas Leak Detector

Forced draught gas burner

QD6310. Fixed Gas Detector Operation Manual

CPS-1 USER S MANUAL AIR INLET / CURTAIN CONTROL

Safe T Net 210. Instruction Manual Part Number Mar2010

Model 4001 Series Single Channel Controller

03.03.mmm REV.2 09/01

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

ST1. Mod. USE AND MAINTENANCE MANUAL

AUTOMATIC SLICING MACHINE

Pre-March 2016 Design - Click to be redirected to newer SBS-H2 design SBS-H2. Hydrogen Gas Detector Kit

Flame Simulator User Manual. Publication Rev. A

OPEARATING GUIDELINES FOR AERO-252 (Pages 1 to 3 contain general information on CO Guardian. Pages 4 to 6 contain information specific to Aero 252)

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

Copying contents of this booklet or handing over to third party is strictly forbidden without written permission from Detector Oy.

Operation & Maintenance Manual

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

ELECTRIC ASH CAN Model: CVACASH500 Part No:

Installation & User Manual DURAUTO. Domestic Gas Detector

Model Number Structure

SERIES VAC Microprocessor-Based Intermittent Pilot Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

Snifter ATEX22 VERSION. User Manual. Distributor

Four Channel Gas Detection System AGDS 4. The Home of Control & Automation in Ireland

Two-Channel Gas Controller

SBS-H2. Hydrogen Gas Detector Kit. For battery charging rooms and other areas where hydrogen gas may be present

RK-05 Combustible Gas Transmitter Operator s Manual

Buzzer Unit. TAN-5000 Series. Operating Manual

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions.

INSTRUCTION MANUAL. Software Revision Card 3.2 DOCUMENT SES-KS E REV. 3

Transcription:

Belonging to Made in Italy GS911K Gas Detector GS911K Using the catalytic sensor inside it, the GS911K detector detects the presence of explosive gas such as: Methane, LPG, with trip sensitivity calibrated to 10% of Lower Explosion Limit, and can activate solenoid valves, sirens and any other signal or alarm handling device, by means of the built-in relay. A series of technical features make this gas detector extremely versatile, reliable, accurate, and safe. The internal jumper makes it possible to select the relay impulse functioning, to connect manual reset solenoid valves, or the continuous functioning, to activate class A solenoid valves and sirens. The relay, free of voltage, allows installation of multiple detectors on a single solenoid valve ensuring control of multiple dangerous environments. The detector is complete with a special circuit that controls the catalytic sensor s efficiency level, and signals any possible fault. The external container has an IP42 protection degree. These features make the GS911K reliable for civil environment safety. Installation and user guide F i rm w a re. Versione 3.1 Firmware Version 1.0 COFORMITY E 50194 CEI 216-3 E 50270 Important ote Before connecting the unit careful reading of instruction booklet is recommended, and it is kept in a safe place for future reference. Furthermore, the correct electrical connections according to the enclosed drawings, complying with instructions and regulations in force, is recommended.

Precautions CHECK the integrity of the probe after having removed it from the box. Check that the data written on the box correspond to the type of gas used. When doing the electrical connections, follow the drawing closely. Any use of the detector for purposes other than the intended one is considered improper, and as a result of which BEIAT S.r.l. therefore disclaims any responsibility for possible damages caused to people, animals or objects. ISTALLATIO When performing the installation, please remind that if you pierce the GS911K container, it will lose its properties and its conformity to REGULATIOS. TERMS and EXPECTATIOS: The installation of the GS911K detector, its ordinary and extraordinary maintenance, and its out of service removal at the end of the functional life guaranteed by the manufacturer, must be carried out by authorized and/or specialized personnel. Do not allow it to become wet. The detector can be seriously damaged when immersed in water. Do not drop it. Heavy knocks or falls during transportation or installation can damage the appliance. Avoid abrupt temperature fluctuations. Sudden temperature variations can cause condensation and the probe could work poorly. Cleaning ever clean the device with chemical products. If necessary, wash with a moist cloth. Absolutely avoid using any cloth dipped in thinners, alcohol and chemical detergents. Technical Specifications Power supply... 230Vac 50 Hz +/- 10% Power consumption... 1W @ 230V Range of relay contact switching...10a 250V resistive - 5A 30Vdc resistive Explosive gas sensor... Catalytic Explosion Alarm Threshold... At 10% of L.E.L. Explosive gas detector alarm threshold... Immediate Sensor s faults detected by Fault Circuit... Interruption, short circuit, or wear Audible and visual signal alarm by... LED diode and buzzer Test ase Duration... 60 seconds Functioning Temperature... -10 C to +40 C Functioning Humidity... 0 90% RH non condensed Electromagnetic Compatibility CE Reference orms... E 50270 External degree of protection... IP42 Mounting... External wall mount, or embedded box 503 Body material... ABS self-extinguishing Dimensions... 115x150x50 Warranty... 3 years The installation of the GS911K detector, its ordinary and extraordinary maintenance, and its out of service removal at the end of the functional life guaranteed by the manufacturer, must be carried out by authorized and/or specialized personnel. The CATALYTIC technology sensor duration is guaranteed for 6 years (in clean air). The detector s functioning temperature ranges from -10 C to + 40 C. WARIG! The CATALYTIC probe does not tolerate a gas detection exceeding 100% of L.E.L., with consequent natural death of the sensor. Each immediate puff of gas that exceeds 100% of L.E.L. takes away months of life from the sensor. The detector must be tested by simulating the presence of gas by issuing it from a pre-calibrated testing aerosol. A common cigarette lighter near the sensor does not guarantee excellent functioning. Page 2

Components and commands Year 2010 2012 7 Year 2012 6 5 2 4 1 3 GS 91 1K Methane 8 REPLACED BY 2017 1 2 3 4 5 1) MAIS connected indication LED (O). 2) FAULT indication LED. If this LED turns on, it means that the gas detection catalytic sensor is not working efficiently and must be replaced by an authorized service center. 3) ALARM indication LED. This LED turns on when room gas concentration exceeds the danger level. 4) Jumper to select the relay functioning mode. By closing the two poles, the relay will be set to impulse functioning. That is, when the alarm is triggered, the relay will close the C and A contacts for about 90 seconds, and then will reopen them. This is needed to prevent damaging some types of manual reset solenoid valve coils. By opening the two poles, the relay will be set to continuous functioning. 5) Catalytic sensor for Methane or LPG explosive gas detection. 6) TEST button. This button is used to simulate a gas leak, after installation. 7) Identification label, registration number and manufacturing year, located under the ABS small dome. 8) Label of the gas sensor expiration date. This label must be applied by the technician during the installation and remembering that the gas sensor must be reviewed after 5 Years. Dimensions 5 mm 150 mm Embedded box 503 105 mm 70 mm Page 3 34 mm 50 mm 84 mm 115mm

Installation measures and positioning The position of the detector is a crucial factor for its correct functioning during gas detection. In order to obtain the maximum results from a device and minimize the probability of false alarms, it is recommended to follow this scheme and keep in mind the following general regulations. The detector must be located at different heights, according to the type of gas. These heights are: - 30 cm from the lowest point of the floor in order to detect heavy gases, LPG, etc. - 30 cm from the highest point of the ceiling in order to detect light gases, Methane - The detector should not be placed near the appliances to be controlled (boilers, burners, industrial kitchens, etc.) but on the opposite wall. - The detector should not be affected by smoke, vapour, etc. as they could distort its measurement. It should be located away from sources of heat, ventilators or fans. Detector Gas METHAE Detector Gas LPG YES 1-4 m 30 cm ma x 1-4 m 30 cm ma x O! O! Turn on and testing Furthermore, the correct electrical connections according to the enclosed drawings, complying with instructions and Regulations in force, and the use of the safety fuse, are recommended. Indeed, the most essential factor for the proper functioning of the GS911K is its correct installation. By following the instructions in this paragraph high precision can be obtained together with the absence of false alarms. Once the device has been turned on, the MAIS LED lights up, and the GS911K is ready for detection after 60 seconds. Press the button near the detection capsule to simulate the presence of gas. The ALARM LED lights up, and the relay shifts its functioning mode after one second. After the alarm, the LED will turn off, the buzzer will stop, and the connected appliances will be turned off. To complete the general test, issue gas from a pre-calibrated aerosol within 20% of L.E.L. Testing using a common cigarette lighter could damage the sensor. Page 4

The installation of the detector does not exempt from...... The compliance with all regulations concerning the characteristics, installation and use of gas appliances. The ventilation of the spaces and the elimination of combustion products are described in the UI norms according to ART. 3 LAW 1083 / 71 and relevant legal provisions. WARIG! Actions to be taken in case of alarm 1) Put out all free flames. 2) Close the main gas tap or the LPG cylinder tap. 3) Do not turn any lights on or off; do not turn on any electrical device or appliance. 4) Open windows and doors in order to increase ventilation. If the alarm stops, its cause must be found and the relevant consequent measures taken. If the alarm continues and the cause of gas presence cannot be found or removed, abandon the building and call the emergency services when outside (fire department, distributors, etc.) Before calling a technician - If the device does not start up. Check that the 230V power is correctly connected. - If the fault LED lights up. If the YELLOW LED is remains O, check the detection capsule status. It is probably faulty and has to be replaced. Call an authorized technician. - If the detector is repeatedly issuing an alarm. Check that there are no gas leaks. If the alarm signal and the FAULT indicator light turn on together, proceed as in the previous paragraph. - If the detector is issuing an alarm and does not shut off the devices connected to it. Check that the wiring is correct and that the jumper that carries power to the relay has been set properly. All relays are free from electrical power. Check the drawing of the connections. Page 5

Electrical connections WARIG Before connecting to the mains power, ensure the voltage is correct. Carefully follow the instructions and the connections according to Regulations in force, keeping in mind that the signal cables should be laid separate from the power cables. WARIG! All relays are free of voltage. Connection scheme of GS911K detector O Jumper for Relay working Mode 1) With the Jumper opened the relay works in continuos Mode. 2) With the Jumper closed the relay works in pulsed Mode. The pulse duration is 5 seconds C 1 2 3 4 5 C 230 V. Relay Main Alarm One detector with 230V normally closed valve WARIG! All relays are free of voltage. O C C 1 2 3 4 5 230 V. Electrovalve Page 6

One detector with 230V normally open valve WARIG! All relays are free of voltage. O C C 1 2 3 4 5 230V ca Electrovalve One or more detectors with 230V normally open valve 1 2 3 4 5 1 2 3 4 5 230V ca One or more detectors with 230V normally closed valve 1 2 3 4 5 1 2 3 4 5 230V ca WARIG! All relays are free of voltage. Page 7

ISURACE. This device is insured by the SOCIETÀ REALE MUTUA for the PRODUCT'S GEERAL LIABILITY up to a maximum of 1,500,000.00 EURO against damages caused by the device in case of failures in functioning. WARRATY. The warranty term is 3 years from manufacturing date, in agreement with the following conditions. The components acknowledged as faulty will be replaced free of charge, excluding the replacement of plastic or aluminium cases, bags, packing, batteries and technical reports. The device must arrive free of shipment charges to BEIAT S.r.l. Defects caused by unauthorized personnel tampering, incorrect installation and negligence resulting from phenomena outside normal functioning shall be excluded from the warranty. BEIAT S.r.l. is not liable for possible damage, direct or indirect, to people, animals, or things; from product faults and from its enforced suspension of use. Made in Italy GS911K GAS DETECTOR Styling by b&b design TO BE FILLED AFTER ISTALLATIO Purchase Date Stamp and signature of the dealer Registration umber In agreement with our continuous development policy, we reserve the right to modify our products without notice. BEIAT S.r.l. Via G. Bossetto 3-10073, Ciriè (TO) - ITALY Tel. 011.921.04.84 - Fax 011.921.14.77 E- mail - info@beinat.com - http:// www.beinat.com