International Journal of Advanced Engineering Research and Science (IJAERS) Vol-3, Issue-2, Feb- 2016] ISSN:

Similar documents
Keywords : Evaporative cooling, Saturation efficiency, Cooling capacity, Cooling pad, Cellulose, Aspen, Coconut coir. IJSER

Scientific Principals and Analytical Model. Charcoal Cooler. Lisa Crofoot MECH 425, Queens University

Theoretical Performance Analysis Of Direct Evaporative Cooler In Hot And Dry Climates

INTERNATIONAL JOURNAL OF APPLIED ENGINEERING RESEARCH, DINDIGUL Volume 1, No 4, 2011

Modified Air Cooler with Split Cooling Unit

EXPERIMENTAL INVESTIGATION OF COMPARISION OF AIR COOLED AND WATER COOLED CONDENSER ATTACHED WITH COOLING TOWER

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

Effect of Operating Parameters on the Performance of Direct Evaporative Cooler

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY

Design and Development of Modified Air Cooler and Storage System

Scientific Journal Impact Factor: (ISRA), Impact Factor: Methodology. [Yadav, 3(9): September, 2014] ISSN:

Energy Consumption Reduction of AHU using Heat Pipe as Dehumidifier

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Adsorption refrigeration system using waste heat

EXPERIMENTAL INVESTIGATION OF DIRECT EVAPORATIVE COOLER WITH HEMP AND ABACA COOLING PAD MATERIAL

IJIRST International Journal for Innovative Research in Science & Technology Volume 1 Issue 12 May 2015 ISSN (online):

PERFORMANCE EVALUATION OF TWO STAGE AIR COOLER IN DIFFERENT SPEED

Scholars Research Library

Experimental Analysis of Open, Simple and Modified Greenhouse Dryers for Drying Potato Flakes under Forced Convection

Experimental Study of Alternatives to Sand in Zeer Pot Refrigeration Technique

9. ENERGY PERFORMANCE ASSESSMENT OF HVAC SYSTEMS

AN ENVIRONMENT FRIENDLY COOLING OPTION

Experimental Investigations of Different Types of Condensers on the Performance of Household Refrigerators

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

AND AIR-CONDITIONING. Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University

FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points

Institute of Aeronautical Engineering (Autonomous) Dundigal, Hyderabad B.Tech (III II SEM) MECHANICAL ENGINEERING

Two Stage Indirect/Direct Evaporative Cooling

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

Experimental Study of Direct Contact Condensation of Steam on Water Droplets

All rights reserved, Armando B. Corripio, PhD, PE, Solid Dryer Design Introduction Continuous Dryer Design...

Hygrometry. The art or science of humidity observation

EXPERIMENTAL STUDY OF CENTRIFUGAL HUMIDIFIER FITTED IN AN INDUSTRIAL SHED LOCATED IN TROPICAL CLIMATES

ICMIEE-PI Design and Construction of a portable air cooler

UNIT 1 AIR CONDITIONING 1. Write the various psychometric processes? Explain any four processes with neat sketches?

DESIGN AND FABRICATION OF AN EVAPORATIVE COOLING SYSTEM. Md. Rakibuzzaman 1,* and M. A. Wazed 2. Chittagong-4349, Bangladesh 1,*

Air Conditioning System with Modified Condenser Ducts and Evaporative Cooling

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 01, 2016 ISSN (online):

MODULE 6 HUMIDIFICATION AND AIR CONDITIONING

Analysis of Coefficient of Performance & Heat Transfer Coefficient on Sterling Cycle Refrigeration system.

Design and Development of Combined Direct and Indirect Evaporative Cooling System

Dynamic performance of a novel dew point air conditioning for the UK buildings

LEAKAGE MONITORING OF SEAL PLUG FOR INDIAN PRESSURIZED HEAVY WATER REACTOR BY PSYCHOMETRICS ANALYSIS METHOD

International Journal Of Core Engineering & Management (IJCEM) Volume 2, Issue 9, December 2015

Design Optimization of Atmospheric Water Generator

System-CoolAC. Bharatividyapeeth College of Engineering, Deekshant Bharti Scholar, New Delhi, India


Available online Journal of Scientific and Engineering Research, 2018, 5(11): Research Article

Performance Optimization of the Evaporative Condenser Design

For an ideal gas mixture, Dalton s law states that the sum of the partial pressures of the individual components is equal to the total pressure.

EXPERIMENTAL VERIFICATION OF PERFORMANCE OF CAPILLARY TUBE USING VAPOUR COMPRESSION REFRIGERATION SYSTEM

Experimental & Analytical Investigation on Modified Solar Dryer with Recirculation of Air

Open and Closed Door Moisture Transport and Corresponding Energy Consumption in Household Refrigerator

Design, fabrication and testing of Evaporative Desiccant Cooling system

Experimental Study And CFD Based Simulation of Closed Loop Pulsating Heat Pipe Using of Refrigerants (R-134a)

Numerical Simulation of Window Air Conditioner

Experimental Analysis and Performance Comparison between Evaporative Cooling System and Air Conditioning System

Summary of Comments (Washington Revisions November 7, 2000) Update November 27, 2000

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS

Feasibility of a Liquid Desiccant Application in an Evaporative. Cooling Assisted 100% Outdoor Air System

Psychrometrics. Outline. Psychrometrics. What is psychrometrics? Psychrometrics in daily life and food industry Psychrometric chart

STUDY ON TEMPERATURE, RH AND AIR FLOW VELOCITY DISTRIBUTION INSIDE THE GREENHOUSE EFFECT SOLAR DRYER

An Experimental Analysis of Direct Evaporative Cooler by Changing its Cooling Pads

Chapter 14 GAS VAPOR MIXTURES AND AIR-CONDITIONING

ENERGY SAVING IN A DOMESTIC SPLIT-TYPE AIR CONDITIONER WITH EVAPORATIVE COOLING SYSTEMS

Comparison Simulation between Ventilation and Recirculation of Solar Desiccant Cooling System by TRNSYS in Hot and Humid Area

FABRICATION SOLAR REFRIGERATION SYSTEM BY PELTIER EFFECT

SIDDHARTH GROUP OF INSTITUTIONS :: PUTTUR Siddharth Nagar, Narayanavanam Road AUTONOMOUS QUESTION BANK (DESCRIPTIVE) UNIT I

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

Economical and Energy Efficient Air Conditioner Using Calcium Liquid as a Secondary Refrigerant.

S.A. Klein and G.F. Nellis Cambridge University Press, 2011

Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling of Gas Turbine

Design and Development of Water Cooled Condenser for Domestic Refrigerator

International Journal of Engineering Research (IJOER) [Vol-1, Issue-3, June- 2015]

s. Properties for R134a are as follows : Saturated R-134a Superheated R-134a

Thermodynamics II Chapter 6 Mixtures & Psychrometry

REVIEW OF DESIGN OF SINGLE EFFECT SOLAR POWERED VAPOUR ABSORPTION AIR CONDITIONING SYSTEM

II. OBJECTIVE OF RESEARCH

Use of heat pump dehumidifiers on industrial drying of chili

EXPERIMENTAL INVESTIGATION OF VAPOUR ABSORPTION SYSTEM

Evaluation of Available Heat at the Exhaust of Automotive Engine for Air Conditioning by Vapor Absorption System

Optimisation of cooling coil performance during operation stage for improved humidity control

MODERN EVAPORATIVE COOLER

EXPERIMENTAL AND CFD STUDIES ON SURFACE CONDENSATION

International Journal of Advance Research in Engineering, Science & Technology SOLAR HUMIDIFIER

Experimental Investigation of a Hybrid Evacuated Tube Solar Collector

AR/IA/UP 241 Lecture 5: Psychrometrics

Analysis of Energy Consumption for Biomass Drying Process

Development of a Psychrometric Test Chamber. Michael J. Swedish. Associate Professor Mechanical Engineering Department Milwaukee School of Engineering

WASTE HEAT RECOVERY FROM DOMESTIC REFRIGERATOR Soma A. Biswas 1, Sandeep M. Joshi 2 1,2 Pillai College of Engineering

Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers

Impact of indirect evaporative air cooler type on the performance of desiccant systems

Thermal Performance Enhancement of Inclined Rib Roughness Solar Air Heater

DESIGN, DEVELOPMENT AND TESTING OF CROSS FLOW CIRCULAR HEAT PIPE TO COOLING OF OIL

Basic Input Data Needed to Develop a High Performance Fan/Blower with Low Noise, Energy Saving and High Efficiency

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Influences of temperature of vapour-condenser and pressure in the vacuum chamber on the cooling rate during vacuum cooling

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Transcription:

Fabrication of Direct Evaporative Cooler and its Performance Analysis for Different Materials In Hot and Dry Climates Utkarsh Tripathi 1, Dr. R.M.Sarviya 2, Veeresh Fuskele 3 1Department of Mechanical Engineering, MANIT, Bhopal, India 2Professor & Dean S/W, Department of Mechanical Engineering, MANIT, Bhopal, India 3Department of Mechanical Engineering, MANIT, Bhopal, India Abstract This paper studies the performance analysis of different evaporative pad materials such as Charcoal, Activated Charcoal, Sponge of Sponge Guard ( Gilki in Hindi), brick bats and a combination of Wood Wool and Charcoal has been done in a specially design and fabricated evaporative cooling system. The objective is to analyse cooling effectiveness and cooling capacity at different velocities of air. Indore MP and nearby places where temperature is in the range of 39 C to 42 C in summer days with relative humidity 22% to 29 %, in this scenario evaporative cooling is a good option. This analysis has been done on a special evaporative cooler maintains cool interior temperature for food preservation purpose. While these devices are not typically capable of maintaining temperatures of 2-3 degrees Celsius, they can be significantly cooler than ambient temperature. An evaporative cooler uses the principal of evaporative cooling to maintain a cool interior temperature for refrigeration and food preservation. The device is constructed from an open timber frame with evaporative pad material filled sides, which is kept continually moist. As warm, dry air flows through the moist material, water is evaporated into the air and it is cooled. Keywords Evaporative Cooling, Direct and Indirect Evaporative Cooling, Cooling Effectiveness and Cooling Capacity. Activated charcoal I. INTRODUCTION 1.1 Evaporative Cooling: The principle underlying evaporative cooling is the fact that water must have heat applied to it to change from a liquid to a vapor. During evaporation, this heat is given to the water from dry air in the form of sensible heat when it comes in contact with water. Water takes this heat in the form of latent heat to convert its phase. 1.1.1 Direct Evaporative Cooling: In direct evaporative cooling the air to be cooled comes in direct contact with water. In such a process air gets humidified. 1.1.2 Indirect Evaporative Cooling: In indirect evaporative cooling, the air to be cooled does not come in direct contact with water. Instead, it is in indirect contact with a surface that is maintained at lower temperature with flow of water. In such a process its absolute humidity is not affected. 1.2 Activated charcoal It is a powerful adsorbent known. It is basically a solid material consisting mainly of pure carbon. A characteristic feature is its porous structure and the resulting immense surface area which may be large as 1500 sq m / gm. The surface area of Charcoal in present study is 200 sq m / gm. Activated Charcoal works on the principle of adsorption. Adsorption is an interfacial process involving the collection of gaseous or solute components on the surface of adsorbent solids. This phenomenon is associated with physical attractive forces that bind gaseous and solute molecules commonly known as Vander wall forces. Activated Charcoal for Evaporative cooling- Fig. 1: Pore structure of Activated Charcoal The adsorption power and rate is determined by the kind of activated charcoal, the particle size, the pore size and its distribution. Pore size and its distribution: When the carbon is activated it leads to opening of various pores in its structure. The pores with diameter exceeding 500 A are called macro pores or the transport pores. These pores are larger pores and are not responsible for adsorption directly but they act as wide paths through which organic molecules penetrates. Thus they transport the adsorbent to the smallest adsorption pore site. Pores with diameter below 50 A are called micro pores or adsorption pores. These are the finest pores, which are located inside the carbon particle where the adsorption actually takes place. www.ijaers.com Page 6

For activated carbon to give good performance it needs to have both these pores in good proportion. II. DEVICE CONSTRUCTION AND EXPERIMENT METHODOLOGY The device is a cube or cuboid shaped hollow box constructed from an open timber frame with its four side walls are made of sieves on framed pillars forming a space for filling the evaporative material. The base is closed and insulated and the top face is also insulated except for a 150mm dia exhaust fan fitment The exhaust fan location was optimized using CFD analysis. The results were found better on top facing exhaust fan fitment rather than side facing exhaust fan fitment. Since side facing exhaust would lead to only three effective cooling faces. Also the exhaust fan provided with variable wind velocity scope. Fig.2 CFD Analysis of the design and optimization In all the four side faces different evaporative materials were placed one by one and in combinations also. A water circulation arrangement is also provided ( using both gravity circulation and forced circulation using pumps), and flow rate optimised in such a way that rate of circulation equals to rate of evaporation using number of hole and dia of holes in the pipes. The evaporative material is kept continually moist. As warm, dry air flows through the moist material, water is evaporated extracting the required latent heat from the air and air gets cooled and in turn maintains the interior cooler. Fig. 3: A Schematic explanation of the Construction On complete working setup, results were observed using specific high accuracy instruments. The instruments used were: Fig. 4: Instruments used in the experiment 1) Mercury Thermometer; 2) Wet bulb thermometer 3) Anemometer; 4) Digital contact type thermometer Some Assumptions were made and tried to achieve at the time of experimentation: The conditions are at steady state The cooler will be placed in a shaded region and radiation effects are negligible The top (Except for Exhaust Fan area)and bottom of the cooler are insulated The entire system operates at atmospheric pressure (101.325kPa) The material is kept continually moist (water consumption rate = rate of evaporation) III. NOMENCLATURE AND THEORY T1 Dry Bulb Temperature ( C ) T2 Temperature inside cooler ( C ) Twet Wet Bulb temperature ( C ) Ec Cpu Cpv Cpa Wi RH Wi ṁa Cooling Effectiveness Specific Heat of Moist Air (KJ/KgK) Specific Heat of water vapor (KJ/KgK) Specific Heat of inlet air (KJ/KgK) Specific Humidity of inlet air ( Kg/Kg of inlet air) Relative Humidity Specific humidity of inlet air (kg/kg of inlet air) Mass flow rate of inlet air ( Kg / Sec) 3.1 Cooling Effectiveness: Instruments E c = Actual Cooling = T 1 - T 2 www.ijaers.com Maximum Cooling T 1 - T wet Page 7

3.2 Cooling Capacity: Q= ṁ a *C pu * (T 1 -T 2 ) C pu (moist air) = C pa (inlet air) +W i *C pv 3.3 Factors affecting evaporation Evaporation depends on the following factors Ambient Temperature (DBT) Ambient Specific Humidity (outside air) Surface Area Evaporative Media ( Density) Air Flow Rate Water Temperature The heat removed from a space due to the evaporation of water is given by following equation Where; Q. is the heat removed in kw ṁ e is the rate of evaporation of water in k kg/s h e is the latent heat of evaporation for water (~2270kJ/kg). 3.4 Density of various materials: (Table 1) Material Density (kg/m 3 ) Material Density (kg/m 3 ) Sample Bulk (Whole fruit & Veg) 25g Testing Conditions: Ambient 31 c/70% RH Inside cooler 21 c/90% Sample Bulk (Leafy veg) 5g Charcoal 208 Coconut shredded 352 Carbon solid 2146 Cork solid 240 Cardboard 689 Cotton seeds not de linted 320 Clay wet 1602 Cotton wood 416 Bark wood 240 Lime hydrated 481 Clay dry lump 1073 Mud 1906 Coal Bituminous broken Sugarcane 272 833 Sawdust 210 3.5 Ambient Specific Humidity Average weather data at Bhopal, India (April, May & some part of June-2011) is shown in table no.2. The most frequently occurring condition is B of average maximum DBT 40.1 C and average RH 22.14% is selected for the analysis. All the properties of air are referred at this temperature. (Table 2) Fig. 5: Materials used in the experiment IV. REVIEW OF EXPERIMENTAL WORK AND OBSERVATIONS 4.1CHARCOAL 4.2 ACTIVATED CHARCOAL 3.6 Shelf life of Fruits and Vegetables: ( Table 3) www.ijaers.com Page 8

4.3 SPONGE -SPONGE GUARD ( GILKI IN HINDI): 4.6 WOOD WOOL & CHARCOAL 4.4 BRICK BAT 4.7 Comparative Analysis Of Different Evaporative Pad Materials 4.5 KHAS Hence with varying wind velocity and evaporative material, the combination of Wood Wool and Charcoal has given the highest cooling effectiveness in the setup. www.ijaers.com Page 9

V. CONCLUSION & PROPOSED WORK Fabrication of Direct Evaporative Cooler has been done. The study has been done on in the month of November and December 2012 and March- April 2012. The cooling effectiveness is coming out to be 80.5% for Charcoal, 73.8% for Activated Charcoal, 85.16% for Sponge of Sponge Guard, 74.48% for Brick bats, 84.12 % for Khas and 97.32% for combination of Wood Wool and Charcoal at air velocity 5 m/s. The cooling capacity is 4.85 kj/h for Charcoal, 1.87 kj/h for Activated Charcoal, 5.18 kj/h for Sponge of Sponge Guard, 3.62 kj/h for Brick bats, 4.78 kj/h for Khas and 4.85 kj/h for combination of Wood Wool and Charcoal at air velocity 5 m/s. In hot and dry climate of India, based on summer weather data, most frequently occurring condition of average maximum DBT 40.1 C and average RH 22.14% evaporative cooling is good option. With present efficiency the temperature difference in hot and dry climate of Bhopal is estimated to be 13 C to 15 C. VI. AKNOWLEDGEMENT This research was supported by MANIT, BHOPAL. Special thanks to Dr. R.M.Sarviya, Prof & Dean Mech. Engg. Dept, MANIT, for his guidance and motivation, and Mr. Veeresh Fuskele, Research Scholar, Mech. Engg. Dept, MANIT for his assistance and comments that greatly improved the manuscript We thank our colleague Ms Neelam Dubey, from MITM, INDORE who provided insight and expertise that greatly assisted the research. REFERENCES Literature Review: Different researchers have made the efforts to clear the concept of evaporative cooling and to search an appropriate media, design and process to make the evaporation most effective [1] R.K.KULKARNI and S.P.S.RAJPUT -Theoretical Performance Analysis of Indirect-Direct Evaporative Cooler in Hot and Dry Climates. [2] http://www.academicjournals.org/ajfs -Development of an Evaporative Cooling system for the preservation of Fresh Vegetables: R.K. Kulkarni and S.P.S. Rajput-Comparative performance of evaporative cooling pads of alternative materials. [3] Understanding Evaporative Cooling by Eric Rusten. [4] http://aurocarbon.com/activatedcarbon.html Understanding Activated Charcoal. [5] Mass, weight & density of bulk materials www.simetric.co.uk/ si_materials.html [6] 7.CFM calculation for room http://ag.arizona.edu/pubs/consumer/az9145.pdf [7] Bhopal weather data retrieved from www.tutiempo.net. [8] Mr. S.K. Varde, Chartered Engineers, HVAC & R consultants, Govt. Certified Energy Auditors. www.ijaers.com Page 10