Chapter 26 FIRE PROTECTION

Similar documents
CIRRUS AIRPLANE MAINTENANCE MANUAL

CHAPTER 11 HEATING AND VENTILATION

CHAPTER 21 AIR CONDITIONING

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

BK AND BKT BLOWER ACCESSORY INSTALLATION INSTRUCTIONS

COMPONENT MAINTENANCE MANUAL

INSTALLATION INSTRUCTIONS

KD-27A SERIES DISHWASHERS

INSTALLATION INSTRUCTIONS

WARNING: ELECTRICAL GROUNDING INSTRUCTIONS

Instrument and Control Panels

Installation Instructions

WARNING. Tighten strain relief screws to secure cable. Make sure screw heads are facing up when tightening conduit nut.

Pressurization System

COMPONENT MAINTENANCE MANUAL

CABIN FIRE EXTINGUISHER INSTALLATION

UNDERCOUNTER DISHWASHER

Ceiling Fan Blade Arm Replacement

DOOR AND PANEL PARTS. For Models: MDBH949AWB3, MDBH949AWW3, MDBH949AWQ3, MDBH949AWS3 (Black) (White) (Biscuit) (Stainless)

Installation Instructions for Med Touch Master Alarms - Wireless

Installation Instructions

FRAME AND CONSOLE PARTS

CIRRUS AIRPLANE MAINTENANCE MANUAL

Heating and ventilation system,

Service Bulletin No. 2930

71717 SERIES FLAMMABLE MATERIAL LOCATIONS

Marine Fire Protection. Kidde Residential and Commercial Division 1394 South Third Street, Mebane, NC Tel

FIRE EXTINGUISHER SPACING & INSTALLATION GUIDELINES

SA-3841 User Manuel. 1U 4 Fans Unit with Thermostat Sensor. Version 1.1 Copyright All Rights Reserved

SERVICE INSTRUCTION SI0035 Rev NC Page 1 of 3

Agent Tanks PCL PCL PCL PCL - 600

DOOR AND PANEL PARTS For Model: JDB8700AWP0 (Stainless)

Illus. Part No. No. DESCRIPTION

Viking Installation Guide

DOOR AND PANEL PARTS. For Models: GU2455XTSB3, GU2455XTSQ3, GU2455XTST3, GU2455XTSS3 (Black) (White) (Biscuit) (Stainless)

Heaters and Defrosters

60" Lyndon Patio. Instruction Manual Customer Service :30 AM to 5:00 PM EST, Monday - Friday A Kichler Decor ceiling fan

June 2018 Safety Meeting Fire Extinguishers Part I

Installation Instructions

Carbon Rack Enclosure

C I R R U S HEATING DESCRIPTION A. Cabin Air Heating System - Serials thru

FPU SYSTEMS OPERATION MANUAL (INCLUDING REPAIR PARTS & SPECIAL TOOL LIST) BOH CONTAINERIZED LATRINES BOH FPU Field Pack-up Units

Fire Control Fire Extinguisher (FC5)

FitchTM. Instruction Manual. Includes our Basic Function CoolTouch TM Control System Looks permanent, but goes wherever you go!

DOOR AND PANEL PARTS For Models: JDB3200AWB4, JDB3200AWW4, JDB3200AWS4 (Black) (White) (Stainless)

Heater for BRP Commander. Caution: Before using this product, read this manual and follow all safety instructions. Owner s Manual

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

DISTRIBUTION > HOUSING, HVAC > INSTALLATION > AIR INLET HOUSING

Penner Stationary Patient Lift Safe Operation & Daily Maintenance Instructions

DASSAULT AVIATION Proprietary Data

Questions on Installation? Call: 800.GE.CARES (US) WARNING RISK OF FIRE 4" DIA. METAL DUCT (RECOMMENDED) 4" DUCT CLAMPS (2) OR 4" SPRING CLAMPS (2)

DOOR AND PANEL PARTS For Model: KUDE70FXPA3 (Panel Ready)

ChicagoTM. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

HORIZONTAL COOKING SERIES: 700 / 900 S.A.V MAINTENANCE & AFTER SALES WORK PPS-3WE711911CH

Send Via: Direct Fax: Feedback ID: Additional Request: Action: MISSING To: DAN GRIMWOOD

Orrin. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

SuperKlean Washdown Products

DOOR AND PANEL PARTS For Models: DU1300XTVB0, DU1300XTVQ0, DU1300XTVT0, DU1300XTVS0 (Black) (White) (Biscuit) (Stainless)

52 StarkkTM. Instruction Manual. A Kichler Select ceiling fan

UNDERCOUNTER DISHWASHER MODELS: MDB8959SFE2 (Black) MDB8959SFH2 (White) MDB8959SFZ2 (Stainless) 07/13/ Maytag Part No. W Rev.

CAUTION READ CAREFULLY

DOOR AND PANEL PARTS For Models: KUDC10FXBL1, KUDC10FXWH1, KUDC10FXSS1 (Black) (White) (Stainless)

Illus. Part No. No. DESCRIPTION

Illus. Part No. No. DESCRIPTION

Hatteras BayTM. Patio. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

DOOR AND PANEL PARTS For Models: KUDU02VRSS1, KUDU02VRMT1 (Stainless) (Meteorite)

LED. 60 StarkkTM. Instruction Manual. A Kichler Select ceiling fan

Part Number: RCSTR INSTRUCTIONS CM450 SAFETY REQUIREMENTS

62" LED SPYRA. Product images may vary slightly from actual product. INSTRUCTION MANUAL

Mopar B-Body Condenser Kit with Drier

EXTERIOR 51-1 CONTENTS WASHER TANK AND HOSES... 6 GENERAL... 2 INTERCOOLER & RADIATOR WATER SPRAY SYSTEM... 7 SPECIAL TOOL... 2 FRONT BUMPER...

MODEL /4" Conduit. (By others) Terminal Strips Companion unit (without electronics) not shown. Approximate Preload

OWNER'S SERVICE MANUAL NO INSPECTION, MAINTENANCE AND RECHARGE

DOOR AND PANEL PARTS For Models: KUDS35FXBL8, KUDS35FXWH8, KUDS35FXSS8 (Black) (White) (Stainless)

Powers TM Controls TH 188 Unit Mounted Thermostat

Ceiling Fan Installation Instructions

Technical Data. Name: ERIKA Automat fully automatic machine to divide and to round dough pieces of the same size

26 - EFFECTIVE PAGES. Beechcraft Corporation PAGE 1 HAWKER 900XP ILLUSTRATED PARTS CATALOG DATE CH-SECT-UNIT-FIG

Toll Free: Tel: Fax:

Service. Manual. Trash Compactor. Preferred Service FCU150

1. SAFETY RULES WARNING WARNING. 8. Avoid placing objects in the path of the blades.

Table of Contents What to Expect with Your Installation. Top Housing. Ceiling Plate. Tools Needed.

DOOR AND PANEL PARTS For Models: WDF780SLYB0, WDF780SLYW0, WDF780SLYM0 (Black) (White) (Stainless)

DOOR AND PANEL PARTS For Models: KUDS30IXBL6, KUDS30IXWH6, KUDS30IXBT6, KUDS30IXSS6 (Black) (White) (Biscuit) (Stainless)

HEAT/ COOL/ DEFROST FORD THUNDERBIRD

#ADENCE4- $ESIGNED )NCLUDES #OOL4OUCH4- +ICHLER )NSTRUCTION #USTOMER KHA

Installation Instructions

Select. Sutter PlaceTM. Instruction Manual. A Kichler Select ceiling fan

GETZ MANUFACTURING PART NO.: MODEL: SV1 100 PR VACUFILL SYSTEM (Revised 6/7/05)

Repair Parts List DISHWASHER MODEL NUMBER DW861UQR. When requesting service or ordering parts, always provide the following information:

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

1 of 5 6/28/17, 1:54 PM

Air Conditioning System Installation Manual

Viking Installation Guide

installation and start-up instructions HUMIDIFIERS AND HUMIDISTAT

Section - III SYSTEMS DESCRIPTION

Summer Breeze Heater Service Manual

DOOR AND PANEL PARTS. For Models: KUDS25SHBL1, KUDS25SHWH1, KUDS25SHAL1, KUDS25SHBT1 (Black) (White) (Almond) (BISCUIT)

Transcription:

Chapter 26 FIRE PROTECTION 26-Title Page 1

INTENTIONALLY LEFT BLANK 26-Title Page 2

LIST OF EFFECTIVE PAGES Chapter Section Page No. Date 26 26-Title 1 2 26-LOEP 1 2 26-TOC 1 2 26-20 1 July 28, 2008 2 July 28, 2008 3 July 28, 2008 4 July 28, 2008 26-LOEP Page 1

INTENTIONALLY LEFT BLANK 26-LOEP Page 2

TABLE OF CONTENTS Chapter Section Title 26 Fire Protection 26-Title Title Page 26-LOEP List of Effective Pages 26-TOC Table of Contents 26-20 Fire Extinguisher 26-20-01 Under Seat Fire Extinguisher 26-20-02 Console Mounted Fire Extinguisher 26-TOC Page 1

INTENTIONALLY LEFT BLANK 26-TOC Page 2

26 FIRE PROTECTION 26-20 FIRE EXTINGUISHER The fire extinguisher is located in one of two designated locations. First, located in the flight compartment mounted under the pilot s seat. Second, mounted on the right hand side of the control console above the trim wheel. The fire extinguisher mounted under the pilot s seat is an ABC 2 1/2 lb. dry chemical fire extinguisher. To use the fire extinguisher unclip the latch at the neck of the extinguisher and pull the extinguisher from the mounting latch. The fire extinguisher mounted on the side of the console is a 2B:C 1.6 lb. Halon unit (H 3 R Inc. Model RT A600). To use the fire extinguisher simply pull the unit out of its mounting tube. Unlatching is not required. Reverse the procedure to install the extinguisher. 26-20-01 Under Seat Fire Extinguisher The fire extinguisher latch is attached to a mounting bracket which is secured to the pilot s seat with four clamps. To remove the mounting bracket remove the fire extinguisher then remove the four clamps which secure the bracket to the seat frame. To install the mounting bracket place the bracket in location and secure the four clamps, then reinstall the fire extinguisher. See Figure 26-20-01 for details. CAUTION: If the pilot and copilot seat is switched, ensure that the fire extinguisher is moved to the pilot s side. 26-20 Page 1 July 28, 2008

PILOT S SEAT NON ADJUSTABLE SEAT FIRE EXTINGUISHER MOUNTING BRACKET PART OF 2.5 1A10BC FIRE EXTINGUISHER 8 PLACES SCREW 2 PLACES CLAMP 4 PLACES WASHER 2 PLACES CLAMP 8 PLACES NUT Figure 26-20-01: Fire Extinguisher Mounting Bracket, Under Seat 26-20 Page 2 July 28, 2008

26-20-02 Console Mounted Fire Extinguisher The fire extinguisher mounted on the side of the console is a H 3 R Inc Model RT A600 unit. It is a disposable, non-rechargeable unit. It is filled with 1211/1301 Halon mixture with gross weight of 1.6 lb. The unit has a 2B:C U/L rating and is intended for use on Class B (flammable liquid) and Class C (energized electrical equipment) type fires. The fire extinguisher has a discharge range of 6-8 ft. with discharge time of 10-12 sec. Removal and Installation To remove the fire extinguisher, pull the unit out of its mounting tube. To install the fire extinguisher, gently spread holding tabs and insert the unit into the mounting tube. Weight & Balance Gross Weight = 1.6 lb. Arm = -3.33 in. 26-20 Page 3 July 28, 2008

4, 5 3 2 1. Mounting Tube 2. Fire Extinguisher 3. Adel Clamp 4. Washer 5. Screw 1 VIEW ON RIGHT HAND SIDE (STBD. SIDE) OF CONSOLE Figure 26-20-02: Fire Extinguisher Installation 26-20 Page 4 July 28, 2008