EMS510 PS-1 COMPLIANT OPACITY/DUST MONITOR

Similar documents
EMS520 MANUAL VOLUME 4 Rev 1.3 RCU, Modbus

4500MkIII COMPLIANCE OPACITY AND DUST MONITORING QAL 1 PS-1 ASTM D6216 PROCEDURE 3 PS-11 QUALITY CUSTOMER SOLUTIONS

Instruction Manual Rev 2.0. OPM3000 Opacity/Dust Density Monitor Installation and Operation Manual Rev 2.0

OPM4001 Opacity/Dust Density Monitor Installation and Operation Manual

Instruction Manual IM , Rev 2.0 November 2008 OPM Opacity/Dust Density Monitor.

EMS510 Electrical Wiring Guide Volume 2, Rev 1.4

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

Instruction Manual IM , Rev 1.1 January 2007 OPM Opacity/Dust Density Monitor.

OPAL 200S SERIES OPERATOR AND SERVICE MANUAL OPAL 200 OPACITY & DUST MONITORING SYSTEM OPERATION AND SERVICE MANUAL. Feb-09 1 Revision 1 V46

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

Model DT109D Opacity Measurement System

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Product Overview. Ordering Information DM-LK-D10 DM-LK-D10-C. Dust & Opacity Meter Complete Set Controller Unit. Sender Receiver SDS-V5 SDR-V4 HPB-82S

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

Carbon Monoxide Transmitter

Intelligent addressable fire alarm control panel

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

IRtech. E instruments. IRtech Radiamatic IR20 LS series. Infrared Technology

A New Standard of Excellence

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

The LC-100 s valved manifold controls the flow of air and allows the LC-100 to accurately monitor liquid levels with a minimal air usage.

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

Temperature Controllers

Heating Cable. Description

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

Analog Room Pressure Monitor RPC Series

Beam-A-Temp Portable Infrared Thermometer Measures up to 1832 F/1000 C with 50:1 distance to target ratio. Specifications

SUPREMATouch Modular Fire & Gas Detection System

Turbimax CUE21 / CUE22

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

WASTEWATER Online UV%Transmission Analyzer

K-Controller Brochure.qxp_ Controller Brochure 2/27/17 3:03 PM Page 4 Versa IC Platform

All icon products are. Easy to use: with an intuitive glass touch-screen, wipe-clean graphic user interface with multi-language options.

AquaLynx 200 ADX. Monitoring and Control System. Background. Operation

TS Series. Technical Instructions. Document No. TS-4000 June 25, TS-CE Combustion Enclosures with LMV5. Description

SmartVFD HVAC and BYPASS

SIL 2. Ultima X Series Gas Monitors CERTIFIED

IMR 5000 IMR 400. CEMS Operating Manual IMR USA S/N: Sample IMR Sensors Inside IMR 400. Gas Dryer Inside. IMR Environmental Equipment Inc.

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

E340 BOILER CONTROL INSTALLATION MANUAL

Addressable Fire Alarm Control Panel

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

SERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS

AnaLASER II Detector. Protection Systems. A UTC Fire & Security Company. High-Sensitivity Smoke Detector (HSSD ) FEATURES DESCRIPTION

Zircomat Oxygen Analyzers

Dust Alert 75. *shown with optional external keypad and display

IMR 5000 Operating Manual S/N: SAMPLE For information only! IMR Environmental Equipment Inc.

OTC, OTM and OTI Series Options Index for PLC Control Systems:

GAS PLUS ALARM SYSTEM

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

Rig Protector. Multipoint Critical Gas Detection and Monitoring System

SCC Inc. TS Series. Technical Instructions. Document No. TS 1000 June 25, TS Touchscreen Kits. Description. Touchscreen

Industrial Grade Gas Detection

Meets all design requirements of U.S.EPA. Double pass optical system for accuracy and sensitivity. Modulated light beam to eliminate interference

THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11

Model D12-IR. Digital Gas Transmitter...

PH / ORP Analyzers MODEL OPM223/253. Wedgewood Analytical Inc. Liquid Analytical Measurement & Control Specialists DESCRIPTION FEATURES APPLICATIONS

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

Pump-Down Controller MODEL 4052

Process Gas Chromatograph

DEL MAR SULFURELITE Hydrogen Sulfide Analyzer

Variable Frequency Drive SERIES MP800 VFD

LMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification

Toxic and Explosive Smart Gas Monitor PN / Installation and User Manual

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

SERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

Commercial and Light Industrial Fire Alarm Control Panel

Industrial Grade Gas Detection

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Power Flame Incorporated

INSTALLATION & USER MANUAL

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

Multi-Gas-Controller MGC2

Pump-Up Controller MODEL 4062

SUPREMATouch. Modular Fire & Gas Detection System

Toxic Gas Detection. Model F12. Toxic Gas Detection

NGC-40 Advanced Heat-Tracing Control System

OWNER S MANUAL Manufactured Home Downflow Gas Furnace: MGD-B Series

Dissolved Oxygen Analyzers

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

UDC100 Universal Digital Controller Specifications

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

Transmitter OCX 4400 THE LATEST BREAKTHROUGH FOR COMBUSTION FLUE GAS ANALYSIS. Product Data Sheet PDS A01 February, 2001

Intelligent Single Loop Fire Alarm Control Panel

Across-the-Line SERIES MP300 Combined Manual and Automatic

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

Heating Cable. Description

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

Process Alarm Module RTA 421

MYRIAD DPC DUPLEX PUMP CONTROLLER INSTRUCTION MANUAL VERSION 3.7

Altman Lighting Spectra Cyc UV 50 Specification

DET-TRONICS. SPECIFICATION DATA Eagle Quantum Premier Fire and Gas Detection / Releasing System APPLICATION FEATURES

Two-Channel Gas Controller

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

Intelligent 2 & 4 Loop Fire Alarm Control Panels

Transcription:

EMS510 PS-1 COMPLIANT OPACITY/DUST MONITOR The EMS510 provides continuous, low maintenance, precision measurement of Opacity and Dust (mg/m3). It is designed for monitoring visible smoke in the exhaust gas of industrial combustion or air filtration processes. Manufacturing and Servicing Opacity & Dust Monitors Since 1990

EMS510 OPACITY & DUST MONITOR Key Features Standard System Configuration ASTM D 6216 and 40 CFR 60 PS-1 Compliant Available Factory and Field Certification Custom Microprocessor Controlled Transceiver RS485, Modbus Communication, Optional Ethernet and Wireless Dual beam measurement with Green LED Source Automatic (Internal or External) and Manual On- Line Calibration Available Opacity or Dust Program Meets PS-11 requirements (Dust Program) Central Information Display (CID)

EMS510 OPACITY & DUST MONITOR System and Measurement Principle The EMS510 system consists of an optical transceiver mounted on one side of the stack and a retro reflector mounted on the other. The LSEM (LED Electronic Modulation) measurement beam is projected across the stack to a retro reflector, which reflects it back across the stack. The output of the transceiver is sent to the user interface via Modbus RS485 where the signal is analyzed and displayed. This intuitively designed controller. Transceiver Microprocessor Board Applications Power Plants Boilers Electrostatic Precipitators Filter Bag Houses Refineries Cement Plants Combustion Furnaces Process Industries

EMS510 OPACITY & DUST MONITOR Smart Service Module (SSM) The newly developed Smart Service Module is located inside the stainless steel weather cover and utilizes Modbus communication over RS485 (2 wire) cable connected to the transceiver and control unit. Many of the control unit functions are accessible at the sensor location. This service module is useful for trouble shooting, PM/Audits and setup. It also eliminates the necessity for a second technician at the mounting location Optional Accessories/Services Stainless Steel Weather Covers Customizeable CID (Central Information Display) Wireless Communications Custom Engineering Startup, Certification and Preventative Maintenance Procedure 3 Required Off- Stack Zero Kit Certified Neutral Density Filter sales and calibration

Design and performance: Spectral Response Angle of View/Angle of Projection Calibration Error/accuracy Response time 24 Hour Zero/ Calibration Drift Operational Period Zero/Span Calibration Process gas Meet or exceeds 40 CFR 60 appendix B, PS-1 and ASTM D 6216 Peak 500 to 600nm, less than 10% of peak response outside 400 to 700 nm. AV <4 o, AP <4 o. +/- 1% of full scale < 10 second < 0.5% / < 0.5% In excess of PS-1 required 336 Hrs. Manual or automatic with zero mirror and neutral density filter Up to 750 o F (400 o C) standard, higher availablecontact factory. Severe Weather Cover: Material Quick release pins Mounting Standard Blower Max stack pressure Wind Speed Ambient temperature limits Protection for 308 Stainless Steel 2 for bottom and 2 for top release. 3 inch IPS, 150# flange. Others available. Single phase, 110/220VAC 50/60Hz +/- 5 inch WC, with the proper installation of purge blowers. < 60 mph -40 o F to 130 o F (-4 o C to 54 o C) Transceiver and Retro-reflector components; purge blowers.

EMS510 Opacity Control unit: Enclosure EMS provided 24Vdc Supply Graphic Display Approvals Measurement Ranges Display Resolution Process Display screens Battery back up S.D. Card 4-20mA Outputs Relay Contacts Alarm Reset Cal cycle initiate Opacity Exit Correlation (Lx / 2*Lt) Environment Environmental Monitor Service, Inc. IP65/NEMA4X (when panel mounted), 96x96x64mm (3.8" x 3.8" x2.58"). Power 24Vdc +/- 10%. Input: 90-240 VAC, 50/60 Hz, 0.55 amp +10%; 1.5x2.25 Viewing area, LED Backlight CE, UL, cul -5 to 99% Opacity 0.1% for Opacity 3 Selectable pages, Instant, average, split screen. 7 years typical at 25 o C Optional - Back up by SD memory card. Two (2), 800 ohms max individually customer selected F.S. ranges and modes. 6 relays for alarms, Field programmable. Automatic and manual. Manual on demand, Remote initiated or Internal Clock. 0.3 to 1.0 Panel mounted IP65 / NEMA4X (front panel), Operational temperature 0 to 50ºC (32 to 122ºF), Storage temperature -20 to 60ºC (-4 to 140ºF), Relative Humidity (RH) 5% to 95% (non-condensing) Network Protocol: MODBUS (ASCII or RTU mode), type RS-485

EMS510 Dust Control unit: Enclosure Environmental Monitor Service, Inc. IP65/NEMA4X (when panel mounted), 96x96x64mm (3.8" x 3.8" x2.58"). Power 24Vdc +/- 10%. EMS provided 24Vdc Supply Input: 90-240 VAC, 50/60 Hz, 0.55 amp +10%; Graphic Display Approvals Measurement Ranges Display Resolution Process Display screens Battery back up S.D. Card 4-20mA Outputs Relay Contacts Alarm Reset Cal cycle initiate 1.5x2.25 Viewing area, LED Backlight CE, UL, cul 0-2000/Actual mg 3, -5 to 100% Opacity, 0-2 Optical Density 0.1 for Opacity and mg, 0.001 O.D. 5 Selectable pages, mg, mg/o.d., O.D., mg/opacity, Opacity 7 years typical at 25 o C Optional - Back up by SD memory card. Two (2), 800 ohms max individually customer selected F.S. ranges and modes. 6 relays for alarms, Field programmable. Automatic and manual. Manual on demand, Remote initiated or Internal Clock. Opacity Exit Correlation (Lx / 2*Lt) 0.3 to 1.0 Environment Inside cabinet IP20 / NEMA1 (case), Panel mounted IP65 / NEMA4X (front panel), Operational temperature 0 to 50ºC (32 to 122ºF), Storage temperature -20 to 60ºC (-4 to 140ºF), Relative Humidity (RH) 5% to 95% (non-condensing) Network Protocol: MODBUS (ASCII or RTU mode), type RS- 485.

EMS510 Smart Service Module Enclosure Graphic Display Approvals Network RCU Display Resolution Process Display screens Battery back up Cal cycle initiate Environment EMS provided 24Vdc Supply Network 2-wire to EMS Control Unit Environmental Monitor Service, Inc. Stainless Steel when in EMS WC, NEMA 4X plastic when stand alone. 1.5x2.25 Viewing area, LED Backlight CE, UL, cul Protocol: MODBUS type RS-485. 0.1 for Opacity RCU, mg, 0.01 O.D. with DUST RCU Local display for, Sensor data, Service selections, Fault displays. 7 years typical at 25 o C Manual, Remote and Internal Clock. Panel mounted IP65 / NEMA4X (front panel), Operational temperature 0 to 50ºC (32 to 122ºF), Storage temperature -20 to 60ºC (-4 to 140ºF), Relative Humidity (RH) 5% to 95% (non-condensing) Input: 90-240 VAC, 50/60 Hz, 0.55 amp +10% Protocol: MODBUS (ASCII or RTU mode), type RS-485, optically isolated, RS-232. RS485 Modbus to Control Unit

EMS510 Order Sheet Part # instructions: Choose one number from the left from each category to create the part number. Example EMS510-1-3-8-21, MSRP $13,285.00 1 EMS510 Standard Opacity, PS-1 Optics, Smart Service Module, Auto Zero/Span solenoid Microprocessor system. $ 10,000.00 2 EMS510 Standard Dust, PS-1 Optics, Smart Service Module, Auto Zero/Span solenoid Microprocessor system. Controller Options 3 Standard Controller with Snap-in (8 Relays, 8 Digital Inputs and 2 $ 10,000.00 $ 525.00 Analog (4-20 ma) Outputs. 4 Standard Controller (RS485 Communications) $ - Measurement Path Length 5 Retro Assembly 3-15Ft. $ 750.00 6 Retro Assembly >15Ft to 21Ft. $ 750.00 7 Retro Assembly >21Ft to 40Ft. $ 1,500.00 8 Retro Assembly >40Ft to 50Ft. $ 1,800.00 9 Retro Assembly >50ft $ - Weather covers and Air Purge 10 Severe Weather Cover pair: Stainless Steel Construction. $ 2,535.00 11 Severe Weather Covers with Single Air Purge Blower: Stainless $ 3,950.00 Steel Construction. 12 Severe Weather Covers with Dual Air Purge Blowers: Stainless Steel Construction. $ 5,200.00 13 Pair of Opacity Air plenum Plant Air Adaptors, accepts 1/4" or $ 85.00 1/2" NPT 14 Set of Two Negative Draft Filter Assemblies for Opacity Monitors $ 87.00 15 None or N/A $ - Audit Kit 16 Micro-turn 200 Opacity Audit Kit and On-Line Reflector Test Kit: Includes 3 Neutral Density Filters with Values to Meet PS-1 in Hard Carrying Case. 17 None or N/A None $ 1,606.00