Intensity Level. Intensity Control. Mounting Plate. Signal Type Switch Signal Ports USB DC Power Port

Similar documents
Intensity Level. Intensity Control. Signal Type Switch. 12V Power Port. Signal Ports

PARTS & SERVICE MANUAL

LED Emergency Battery Backup Installation Instructions Ordering Code: EB23UQ

EF3003 SF3003 DF3003

CCS-100. Installation Manual

BF5000NT BF5000 EF2604 SF2603 DF2603

HPNLS-LO. Installation Manual

Service Manual. Model Number: DFR2651L. UL Part Number

PACK TRAVEL INSTRUCTION MANUAL

PARTS AND SERVICE MANUAL FOR. DIMPLEX PURIFIRE ELECTRIC STOVE Model TDS8515

LED Emergency Battery Backup

INSTALLATION INSTRUCTION for ceiling fan

FIELD-INSTALLED MOTION ACTIVATED LED DIMMER CONTROL

IMPORTANT SAFETY INFORMATION

IMPORTANT SAFETY INFORMATION

PARTS AND SERVICE MANUAL FOR THE 23 COMPACT FIREPLACE

Service Manual. Model Number: Compact Fireplace DF203A DF2006. UL Part Number to 800

Service Manual. Model Number: DF2624L. UL Part Number

3SA60 3SA60+LED. Vogue & Vogue Plus. Net weight. This instruction contains 11 pages:

IMPORTANT SAFETY INFORMATION

CEILING FAN OWNER'S MANUAL

RADIO-ALARM CLOCK DOCKING STATION ipod / iphone

Hi-Tech, Low Cost Stanley Solutions. Product Brochure

Smart-Wall TV Kit - Installation & Operation Instructions -

CEILING FAN OWNER'S MANUAL

ELECTRONIC SOUNDER STROBE Model : AVD-C407

ETN1000/MIGA - Operating manual

TOUCHSTONE Dual Variable Speed System. Installation & Operating Manual with Troubleshooting and Configuration Guide

Simple to Set Timer (SST) Frequently Asked Questions

Service Manual. Model RLG20 RLG25. Part Number

Service Manual. Model Number: DF2024. UL Part Number

Install Guide MXS-BRO SERIES SMALL BRO LED MULTIPLE RECESSED

HP-SUBMERSIBLE. Installation Manual WARNING: DO NOT LIFT FIXTURE BY CABLES.

IMPORTANT SAFETY INFORMATION

PARTS & ACCESSORIES INSTALLATION AND SAFETY INSTRCUTIONS ITEM NO.:60010BZGTGLD SAFETY PRECAUTION. Canopy. Downrod. Housing. Transmitter CR2032/3V

CEILING FAN OWNER'S MANUAL

INSTALLATION INSTRUCTIONS NeoSol DS LED Horticulture Fixture

ARTEMIS Series of Low Occupancy LED Ceiling Mounted Fixtures (Including Stairwells) Installation & Operation Guide

CR9934 ROBERTS. PLL Dual Alarm Clock Radio. Sound for Generations. Please read this manual before use

BST-MG07 Multi-gas Detecting Alarm Manual Instruction

CEILING FAN OWNER'S MANUAL

FLEX DC SIDE EMITTING

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670

User s Manual. Timer Control LED Lighting System

Service Manual. Model Number: DF2524L DF2524G. UL Part Number

Clamp 4W Clamp 8W. Owner s Manual

1 x4 Dimmable LED RetroFits

Operating Instructions Model : HC HC-N

SPLIT TYPE. Instruction manual

MaxLite LED High Bay Fixtures

M650-38A-OAK ELECTRIC FIREPLACE HEATER NDF-65NB-1 INSTRUCTION MANUAL

INITIALIZATION / INSTALLATION

CR-A119 INSTRUCTION MANUAL. Digital AM/FM Alarm Clock Radio with Touch-Sensitive Snooze. Please read this manual carefully before operation

Introduction... 1 System Overview... 1 System Diagram... 2

Intelligent Super Toilet AFC230 User Instruction Manual

Service Manual 26 Self Trimming Fireplace with 3 Stage Remote

THINLINE TL2 SERIES INSTALLATION AND OPERATING INSTRUCTIONS

Signature Series 418 Mhz COMMUNICATOR RECEIVER INSTALLATION AND OPERATIONS MANUAL

PARTS & ACCESSORIES INSTALLATION AND SAFETY INSTRCUTIONS ITEM NO.:60006PC SAFETY PRECAUTION. Canopy. Downrod. Housing. Blade. Transmitter CR2032/3V

Solatube Daylight Dimmer Installation Instructions

S = 1120 Long. M = 1400 Long. L = 1680 Long

Mood Light and Nature Sound Alarm Clock

Service Manual 26 Self Trimming Export Fireplace with 3 Stage On/Off Remote

Kwêbeam GSM/Interface/Repeater Module

INDOOR UNIT/OUTDOOR UNIT

ELECTRIC FIREPLACE OWNER S MANUAL

Infrared Wall Mount Occupancy Sensor

Basic Specifications to Install Tresco Lights Basic Specifications to Install Tresco Lights With With a HArDWIre a HARDWIRE To turn all s on/off at th


IMPORTANT SAFETY INFORMATION

USER GUIDE & INSTALLATION INSTRUCTIONS

Hanson LED C e i l i n g F a n

PVK-80 Power Vent - Installation Instructions -

Sonic Boom Travel & Bed side Alarm Clock with Bed Shaker Model SB200ss-v3

Parts Catalog

IP & SMS Alarm Communicator

INDOOR UNIT/OUTDOOR UNIT

CEILING FAN OWNER S MANUAL

Energy Watch Monitor

HPNLS-RT. Installation Manual

INDOOR UNIT/OUTDOOR UNIT

Installation Instructions

User`s Manual. Using the device The basic diagram of product

PARTS AND SERVICE MANUAL FOR. DIMPLEX PURIFIRE ELECTRIC STOVE Model TDS8515T

ROBERTS. FM / MW dual alarm clock radio with instant time set. Please read this manual before use

Touch Control Beard Trimmer

USER GUIDE & INSTALLATION INSTRUCTIONS

TTT Digital Incubator

BIRKET Specialty Lighting LED BRIK User s Guide

Service Manual 26 Self Trimming Fireplace Model Number: DF2608 DF2622 NBDF2608

Electrical rating 230V AC, 50Hz 100mA max per (maximum 35mA for originating unit with 16 Devices interconnected).

Service Manual. Model Number VCX1525 VCX1525-WH. UL Part Number

RT021 User and Installation Instructions

INSTALLATION MANUAL. Warning and Attention: Outdoor Series RP-SAL-8W-50K-SF-GY-G1, RP-SAL-30W-50K-SF-GY-G1.

Interscan Corporation. Instruction Manual Series Compact Portable Analyzer

Ceiling Fan Ow n e r s Manual

VACUUM CLEANER VCH 9530

General Specifications

WSK300 Multifunction Wall Control

ChargeTime Plus USER GUIDE MODEL: TA-7850

Transcription:

Dimmer User Manual

OVERVIEW This product can dim up to 50 fixtures over 200 feet of signal wire via a 0-10V or PWM signal for uniform control of light intensity delivered to crops. Extending the signal wire more than 200 feet will weaken the signal strength and may reduce the total number of fixtures that can be dimmed. If more than 200 feet of total signal wire is needed, please consult an electrician or contact a Fluence representative at support@fluencebioengineering.com. Please note: This dimmer is meant to control the overall light intensity of your Fluence Bioengineering fixture(s). It is not meant to act as a timer to control photoperiod. Please use a switch or timer to power fixtures on/off for photoperiod control.

Intensity Level Intensity Control Mounting Plate Signal Type Switch Signal Ports USB DC Power Port

1 Install Mounting Plate Attach the mounting plate to the wall with screws. Install away from areas that may get wet. Do not install in environments with 80%+ humidity. Additional Mounting Holes

2 Mount Dimmer Set the bottom of the dimmer into the mounting plate and then push the top of the dimmer in until the mounting clip snaps into place. Mounting Clip

3 Changing Signal Type Use the small switch marked 10V PWN to set the signal type to match your fixture. Move tab right for PWN or left for 0-10V dimming signal

4 Connect the Power Cord Connect the micro USB power cord to the port labeled DC IN and insert the wall adapter into a plug. The screen will flash LO as the battery charges. Please wait at least 30 minutes before connecting to fixture(s). The backup battery lasts roughly 18 hours if the dimmer becomes unplugged*. *Please Note: This dimmer is not designed as a battery powered device. The back-up battery is intended to provide a continuous signal during brief power disconnections. USB Power Cable

5 Connect the Dimmer Signal Cable Using the included pigtails or 3.5mm AUX plug, connect the dimmer signal cable to your fixture(s) or an extension cable leading to your fixture(s). If the dimmer is not working, try reversing the dimming leads or switching the signal type (PWM or 10V). Pigtail Option 3.5mm AUX Option Dimmer Signal Cable MALE 3.5mm AUX WHITE or PURPLE BLACK or GRAY Dim+ BLUE or WHITE or PURPLE Dim- BLACK or GRAY Dimming Extension Cable or Power Supply Dimming Cable FEMALE 3.5mm AUX

6 Wiring Multiple Fixtures

7 Adjust Light Intensity Use the up/down buttons to adjust the light intensity (0-100) to the desired level. Up/Down Dimming Control

8 Secure Cords Loop the dimmer signal cable and power cord around the strain relief tabs to prevent them from becoming disconnected. Strain Relief Tabs

Changing the Dimming Leads If you need to swap the included signal wire leads, use a needle to open the connector and remove wires and remove the needle after new wires are inserted. Insert needle into top slots to remove or insert signal wires Insert signal wires into bottom slots before removing needle to lock wires in place

Install & Usage Guidance Mount dimmer away from wet environments, and always dry hands thoroughly before using. Do not install this dimmer in environments with 80%+ humidity, or in areas likely to be splashed with water. If your fixture(s) appears to reach peak brightness when the dial is at or below 50%, you may need to change the 10V/PWM setting. If the dimmer is still flashing LO after 30 minutes please check that the power cord is fully connected and the plug you are using is hot. If still flashing LO please contact Fluence Customer Support. Some fixtures may emit a soft hum or buzz when dimmed. The light output associated with the lowest dimmer setting is governed by the power supply that drives the fixture. If multiple models of fixtures are connected to the same dimmer, they may power off at slightly different intensity levels. If the dimmer becomes unplugged and the battery loses all charge, SPYDR series fixtures will have zero light intensity, and VYPR series fixtures will go to 10% intensity.

Technical Specifications 180126 70620B PWM Dimming Signal: 0-100% +/- 1% Source/Sink: 40mA DC 0-10V Dimming Voltage: 0-10V +/-.1V Source/Sink: 40mA DC Backup Battery LiPo: 600mA (Fully Charged) USB Charger Input: 120V AC Power Output: 5V at 300mA Family Model Wiring Options C Controllers W Dimmer P Pigtails A 3.5mm AUX