Similar documents
3G GSM AUTO DIALER. Remote monitoring & Control using your mobile phone. MODEL NUMBER 3GAD1

GSM 3G AUTO DIALLER. Remote monitoring & Control using your mobile phone. MODEL NUMBER 3GAD1

2G & 3G GSM Door Contact Alarm

2G & 3G GSM Portable PIR Alarm

2G & 3G GSM Wireless Beam Alarm

GSM 3G AUTO DIALLER PLUS

GSM PROTECT ANTI-THEFT ALARM WITH GPS TRACKING & MOBILE PHONE ALERTS

GSM PERIMETER & INTRUDER ALARM

Kwêbeam GSM/Interface/Repeater Module

To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once.

V1.0. Smart Home Alarm System. User Manual. APP download via QR Code scanning. Please read the manual carefully before using.

GSM RFID VOICE Alarm System

GSM WIRELESS ALARM SYSTEM Model: GSM-0308W

PERMACONN PM1030 Includes DI300. Installation Manual

SMS GSM Alarm Messenger

Mobeye CM2410 GSM fire alarm communicator

Remote switching machines with a SMS text from your mobile phone! Remote Monitoring your assets in the worldwide by your mobile Phone!

With Magictrl, you can control MatiGard anytime & anywhere via your smartphone, even without data network.

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock.

Profile. For a better understanding of this product, please read this user manual thoroughly before using it.

MOBILE CALL GSM Alarm System User s Manual

DYGIZONE GJD910 Lighting Controller & Enunciator

1. Introduction. 2. Product overview

D3D Wi-Fi GSM Smart Alarm System -User Manual

IP & SMS Alarm Communicator

Intelligent Wireless GSM Alarm System

User Manual & Setting Instructions

Security GSM Alarm System

GSM Alarm System. User s Manual. Profile. MOBILE CALL GSM Alarm System

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

Version 1.03 January-2002 USER S MANUAL

System. For a better understanding of this product, please read this user manual thoroughly before using it.

PORTAL USER MANUAL. Mobeye WaterGuard-FS. Float sensor CM2300FS. SW version 5.n

Elderly Care Alarm System

PRODUCT CATALOGUE. Cape Town 18 Darter Road Blue Water Estate Kommetjie. Gauteng 245 Louis Botha Avenue Orchards Johannesburg

Wireless Alarm system s manual

1. Functions of GPS locator ETLOC-30S 3

HELPY QUICK-TL GSM INTL

Inner Range FE3000S. Serial GSM Modem. P/No: INSTALLATION MANUAL

GSM SMS Controller GSM SMS Alarm Unit S130 S140 S150. User Manual

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

GSM Emergency Alarm. User s Manual. For a better understanding of this porduct,please read this user manual thoroughly before using it.

Monitoring Solutions

It is necessary to match all peripherals with the EVOLVEO Alarmex main unit before the first use. For safety reasons, they are not factory paired.

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

DATAssure. Laboratory wireless alarm & monitoring system

Wolf Guard Touch Keypad GSM Wireless alarm system User s Manual

ALARM... CONTROL... PANELS... AND... KEYPADS...- WIRED...

USER S MANUAL HOME ENERGY SAVINGS REMOTE CAMERA INTERNET USER INTERFACE TEMPERATURE ALARMS BURGLARY PROTECTION DOOR SECURITY FIRE SAFETY

SMART SWITCH TECHNOLOGIES. SmartSwitch Yacht-Guard Model SMS-8 Vessel System Monitor Installation Manual

SK642 THE TELEPHONE DIALER REQUIRES A LAND TELEPHONE LINE TO MAKE OUTGOING CALLS AND ELECTRICITY.

1. User features of the GSM dialer

GLOBAL. InstallatIon & operation manual

USER S MANUAL. Profile. MOBILE CALL GSM Alarm System

Ontech GSM 9040/50. Reference Manual English -1 -

your silent and loyal servant

Summit 3208GLD USER MANUAL. Electronics Line

UK MADE GSM SOLUTIONS

EZY SWITCH. SMS-IRR-4 System Monitor Installation Manual

T4000 Security Communicator

SC-F3G User Manual 1.0

Memcom Emergency Telephone

PART NO: TSMS. Designed in Australia by. Instruction Manual. Factory Car Alarm Upgrade Providing Alarm Notification Via SMS Messaging N517

Dual-Network LCD Keyboard Intelligent Alarm

My Visonic SMS App User Guide

User Manual (LS-GSM-006)

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

X64 Wireless Training

The complete wirefree security alarm solution

GSM House Alarm System. User Manual. Ver 1.20 Date Issued:

GSM-SD WITH CALL,SMS,MMS MANUAL

MG Partition 64-Zone Wireless Console with GPRS/GSM Version 1.6. Section Programming Guide

GSM Alarm System. S120 User Manual. Ver 1.00 Date Issued:

MT-S20 USER S MANUAL. (Motor Alarm &Tracker) (Version 1.4)

EM8710 GSM Alarm System Starter Kit

COMMUNICATOR ET08 / ET081

User s guide Personal radio trigger Erik 9100

LEAKSTOPPER MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND OPERATION MANUAL

TYDOM 315. * _Rev.2* GSM domotics transmitter. 1. Presentation

S3 Sim Secual Alarm system with GSM transmitter

Manual GPRS Data Logger PCE-GPRS 2

GPS Vehicle Tracker (GPS+GSM+SMS/GPRS) User Manual (V1.0)

WiFi GSM APP Smart Home Security System

SA 2650 Kit User Manual

Gmini 100. User Guide INTELEC SYSTEMS Intelligent Electronic Systems. Web:

USER MANUAL Mobeye ThermoGuard CM2200

HomeSecure HS-BASIC-V2 Installation Manual: Table of Contents

Snitcher. Installation Instructions

OTP-3GM-P2. Manual. Active Alert 3G GSM 2CH camera & mini DVR. Multi 3G MODULE


600 Range Dialer Installation Manual. Version 1.0

Contents. Glossary

Quick start. 2. Turn on the power. When all the led indicator light turns off, the device status is normal, has entered the work state.

GSM Smart Home Alarm Apparatus. [99+4 defense zones] Instruction for Use

DigiAir QUICK GUIDE & INSTRUCTION MANUAL

AS200 Wireless Alarm, Monitoring and Data Logging System USERS MANUAL

ERS-3600B. PERS-3600B Personal Emergency Reporting System

NESS 5000 SERIES DIALLER

Wireless D.I.Y. Alarm Kit

SMART HOME SECURITY. Dual Network Communicating Alarm System with RFID INVINCIBLE. Instruction Manual. Customer Helpline

Transcription:

GSM AUTO DIALLER WIRELESS ALARM SYSTEM MODEL AD-SD MODEL AD-SD-W www.gsm-activate.co.uk Model AD-SD & Model AD-SD-W PAGE 1

Product Information Our AD-SD Auto Dialler is a versatile unit which can be attached to many of your electronic devices in your homes; work, gardens or wherever you may need it. It will alert you using GSM technology by sending you a text message or phone call to your mobile phone or land line. Therefore alerting you immediately to a problem, failure or status change wherever you are in the world! Our AD-SD-W WIRELESS version has wireless capabilities to make it a standalone alarm using various wireless sensors. Our Auto-Dialler is set apart from other models on the market by being on the quad band frequency meaning it an be used worldwide and we frequently ship models all over Europe, USA and Australia with excellent feedback. The unit is also enclosed in a IP65 rated box which means it is perfectly weathered for outside installation and has passed testing in high temperature and below freezing conditions. Specification GSM Frequency: Quad band freq 850/900/1800/1900/ 3g only model 2100 Mhz. Power Supply Voltage: 9-24 volts DC - 1 Amp Max Current used in standby mode: 60mA Max IP 65 Enclosure rating for outside installation 2 Inputs Neg triggered 1 Inputs poss triggered 8 Amp Relay Output Micro Simcard No land line required Dimensions - L150 x W90 x H45mm Dimensions PCB Only - L125 x W67mm Sim Active Function Operating Temperature: -10...+40 C Programmed by Text / SMS Message Text to test signal strength 2G OR 3G Model - WIRELESS FUNCTIONS MODEL AD_SD_W REFER TO PAGE 8 Wireless Alarm Function Activate Alarm via text message RF 433mhz transmission /receiver - Code EV1527 Range 10 metres line of sight Page 2

INSTRUCTIONS Only for 3G model Dipswitch 2 ON= Relay Mode on 2 OFF= Relay Mode off Ref page 6 Slide the simcard into the holder making sure that the clipped corner of the simcard lines up with the clipped corner of the simcard holder as picture above. IMPORTANT - PLEASE READ PLEASE MAKE SURE YOU DISCONNECT THE POWER WHEN YOU FIT THE SIM CARD THEN PLACE THE SIM CARD WITH THE CLIPPED CORNER FACING IN WARDS. PLEASE SEE PICTURE ABOVE. SIGNAL STRENGTH: To help make sure that you place the unit in a suitable position you can text the unit to see how much signal strength the dialler is receiving by texting the command #SIGNAL# The dialler will perform a test on the signal strength. You will receive a text telling you a signal strength score between 0 up to 30 we strongly recommend that you place the unit where you can receive a signal strength score of at least 10. You will find that with a score of less than 10 the unit will be unreliable. Page 3

How to programme contact numbers After inserting your simcard into the Auto-Dialer turn the unit on and wait until you see the GREEN READY LED is on. This will indicate that you have a mobile signal and the unit is ready for use. You will now need to send a text with the contact number (maximum 3 contact numbers) Note - To avoid confusion we have colour coded the hash (#) and the equals (=) symbols. Example: (ha sh) (1 or 2 or 3) (equals ) (phone numbe r) (ha sh) #1= 07123456789# then send this as a text to the simcard number of your unit #2= 07123562349# then send this as a text to the simcard number of your unit #3= 07123871234# then send this as a text to the simcard number of your unit If you wish to cancel a number follow this example Example: (hash) (1 or 2 or 3) (equals) (DELETE) (hash) #1=DELETE# Then send this as a text to the simcard number of your unit NOTE: Please send one message at a time and wait for the Auto Dialler to send you back the text Acknowledgement NUMBER STORED before you try to add another number. Below is a notepad to help you remember the numbers that you have saved to your unit in the event you need to modify or delete in the future. #1= # #2= # #3= # Page 4

How to program the SMS text message You can now change the alarm message for inputs 1 & 2 to your own choosing. To change the message send the text command as follows. #MESS1= YOUR MESSAGE# The default message is ( input 1 ) #MESS2= YOUR MESSAGE# The default message is ( input 2 ) This will change the message to YOUR MESSAGE Note: You can only use a maximum of 19 characters including spaces for your customised message. Telephone call alerts The auto dialler can be programmed to send you a telephone call after each text alarm has been sent. You will receive approximately three ring tones. The unit will then hang up automatically. This is to prevent call charges being incurred. To set call alerts to ON please send the text message #CALL=ON# The unit will reply back call on To disarm call alerts please send the text message. #CALL=OFF# If the call function has been set to ON you will receive a text message and shortly after a phone call. Page 5

How to Use the GSM Auto Dialler The Auto Dialler has two independent input s Input 1 = Terminal 1 connection. Input 2 = Terminal 2 connection. (Negatively triggered) pulled to ground (Negatively triggered) pulled to ground When the inputs are triggered the GREEN READY LED will flash 6 times to indicate that a trigger has been received and it will send a text / call message to the saved user numbers. Both Input 1, and Input 2, can be triggered independently. The Auto_dialler will reset automatically when the triggered input is released. Note: (Terminal 3) Input 2 only. Can be triggered with a positive supply 12v/24v refer to page 9 (Dipswitch 2= off) ref page 3 How to Use the Relay Output The Auto Dialler has a 8 amp volt free contact relay output which can be used to switch on external electric devices such as lighting, sirens etc. By texting the unit you can turn the relay ON or OFF. Below are examples on how to do this. #REL=ON# - #REL=OFF# This will turn on relay output -This will turn off relay output After each operation the unit will reply with a status report RELAY ON/OFF (Dipswitch 2= ON) ref page 3 The relay can also be setup to pulse for 20 seconds when the inputs have been triggered. To activate this mode you need to set dipswitch 2 to the ON position. Ref page 3 This can be used to reset auxiliary equipment. Page 6

Quick Reference #RESET# Wireless only model Wireless only model Call + Text Text only Ref page 8 To reset the unit back to factory settings you will need to send a text message #RESET# Warning this will reset all of your parameters, only send a reset command when necessary. The green ready led will flash 8x Typical Application of Product Security alarm system applications Supervision and monitoring alarm systems Automatic monitoring system Dipswitch settings Dipswitch 1 = Dipswitch 2 = ON = 3G Selected OFF = 2G Selected ON= Relay Mode on OFF= Relay Mode off Vending machines security protection Pumping stations; tanks, oil or water levels Buildings and real estate Weather stations River monitoring and flood control Fridges/Fish Tanks Farming equipment and security Page 7

Wireless Functions - Model AD-SD-W Wireless Only Model AD-SD-W WIRELESS has an RF module which allows connection to various wireless sensors, that will then trigger the dialler in the same way as hard wiring into input 1 and input 2. Pairing Wireless Sensors To connect wireless sensors you will need to go through a process so that the devices are matched to the receiver on the dialler. Typical Process (can vary dependent on sensor) 1. Switch on the Auto Dialler. 2. Switch on the sensor and allow it to warm up for 15 seconds. 3. Hold down the pairing button on the RF Module for 3 seconds (refer to figure 1). 4. Trigger the sensor. 5. The RF module has a red LED which will flash when pairing is Complete. Door switch 6: Hold down the pairing button on the RF Module for 3 seconds (refer to figure 1). 7. Trigger the door switch. 8. The RF module has a RED LED which will flash when pairing is Complete. How to program the alarm Once the sensors are paired, you can now send a text command to activate the alarm. #ALARM=ON# This will activate the alarm. #ALARM=OFF# This will deactivate the alarm. When sensors/door detect movement You will receive a text message (ALARM TRIGGERED) Note:The alarm will need to be re activated again once it has been triggered, the alarm message cannot be changed from ALARM TRIGGERED. Please Note: Ensure you have already setup your contact numbers as per instructions on page 4 Page 8 Figure 1

NOTE - Please make sure you supply a 9-24 volts DC from the battery terminals via a 2 amp fuse (for alarm panel installations) INPUT 1+2 As you can see in the circuit diagram above the inputs can be activated by pulling the input 1 & 2 to ground. Alternatively input 2 only can be positively triggered by using terminal 3. Rela y Output Volt free contact The relay has Common, Normally Open and Normally Closed contacts which are capable of 8 Amp loads. This is suitable for turning ON or OFF electrical equipment. Alternatively it can be used for resetting your alarm system. The relay can be manually activated by text message commands or it can be set to pulse for 20 seconds when an input has been activated - refer to page 6 For more technical support please browse the FAQ s on our website www.gsm-activate.co.uk Alternatively email our technical support team at technical@gsm-activate.co.uk and we will do our best to reply within 24 hours Monday - Friday. 28/03/2018 - AD PAGE 9