GHE. Dehumidifiers for radiant cooling systems with heat recovery. Display

Similar documents
FHE. Dehumidifiers for radiant cooling systems with heat recovery. Display. Versions

GHE Dehumidifiers for radiant cooling systems with heat recovery

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

G E N E R A L C ATA L O G Dehumidif ers

FH - GH FH - GH. Dehumidifiers for radiant cooling systems. Versions

FH - GH Dehumidifiers for radiant cooling systems

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

LZA High efficiency air to water heat pumps with HP compressor

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

LZT High efficiency air to water heat pumps with E.V.I. compressors

WSK WSK. Water to water chillers and heat pumps VERSIONS ACCESSORIES

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

PRODUCT OVERVIEW. Dehumidifiers

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

Dehumidification and ventilation for residential, industrial radiant systems and swimming pools

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

WZH Ground source heat pumps

WDH WDH. Ground source heat pumps OTHER VERSIONS ACCESSORIES

Dehumidification and ventilation for residential, industrial radiant systems and swimming pools

WHA WHA. Ground source heat pumps OTHER VERSIONS ACCESSORIES

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Air treatment units 0932EN October 2017 Dehumidifier unit for radiant systems Flush-mounting installation in false ceilings

LZT High efficiency air to water heat pumps with E.V.I. compressors

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

WZT High Efficiency Air to Water Split System Heat Pumps With E.V.I. Compressors

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

LZT LZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSION ACCESSORIES

CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

FRAL SRL via dell industria e dell artigianato, 22/C Carmignano di Brenta - PADOVA - ITALY

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

CRIMSON & CRIMSON MAX

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

DOMESTIC DEHUMIDIFIERS FLIPPERDRY

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP

WHA WHA. Ground source water to water heat pumps A ++ A ++ Versions

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz


Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

INDUSTRIAL DEHUMIDIFIERS. Advanced range of compressor and desiccant dehumidifiers. Dehumidification and drying

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

STANDARD DEHUMIDIFIERS EH SERIES TECHNICAL MANUAL

> Refrigerant R-410A. Uniflair LE TDER-TUER kW. Energy-saving units with backward-curved fans. Perimeter cooling for medium/large data center

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

ERAH MC Ka. Range kw. AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS FOR OUTDOOR INSTALLATION (Standard line)

Multi-pipe Units with Scroll Compressors. Model CMAA Cooling capacity kw Heating capacity kw

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%

RECUPERA DRY Controlled mechanical ventilation with dehumidification and air treatment GB 01. Air conditioning. Ideas to install

CHAPTER 6 CONDENSING UNITS

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

BETA ECHOS. Air/water cooled chillers and heat pumps kw. General BETA ECHOS is a range of chillers and ductable air-water heat pumps.

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

DEHUMIDIFIERS FOR SWIMMING POOL. International. ET INTERNATIONAL S.r.l. Via Circonvallazione Est, 32/R Castelfranco Veneto - TREVISO - ITALY

Blue Box Epsilon Echos +

AIR COOLED ROOFTOP UNITS, COOLING CAPACITY FROM 50 TO 240 kw, AIRFLOW FROM TO m3/h

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

H4T R410A. refrigerant

Next MTR kw. technicalcatalogue. Air conditioners for Metrology Labs with upflow air delivery T_NXTMTR_0511_GB

F series close control air conditioners exploit the indirect FREE COOLING system with adiabatic cooling to ensure high system energy savings.

ED.X F Kc DIRECT EXPANSION CLOSE CONTROL UNITS WITH REMOTE CONDENSERS AND ADDITIONAL CHILLED WATER FREE COOLING COIL

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Fan Coil Range HYDRONIC TERMINALS

LER kw. Indoor motor-driven evaporating units. Motor-driven evaporating units LER PLUS


RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

1

4,5 22,5 kw. technicalcatalogue. Air-conditioned server-racks for direct installation into the room T_CLSEVO_0113_GB

Air Cooled Chillers & Heat Pumps WinPACK HE-A

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:

Blower-YEFB-020-3R-1maxVel

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw

LZT LZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. A + A + VERSIONS ACCESSORIES

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

next p dw next p dw rcgroupairconditioning

Aquaflair. Residential and Industrial Cooling Systems

Refrigeration dryers with Energy Saving Impulse Technology and Thermal Mass 0,3-27,0 m³/min Purifying your compressed air, increasing your efficiency.

Motor-driven condensing units MTE MTE R-410A

Very High Energy Efficiency Complete Air Conditioning system

LSN Series. Air cooled water chillers, heat pumps and motocondensing units with axial fans Capacities from 4 to 40 kw.

Also available with the new i-life R-Slim inverter and radiant panel version. Perfect comfort. Silent operation. Real energy savings

> > > Heat pump systems. Water Chillers. Dehumidifiers

Transcription:

GHE Dehumidifiers for radiant cooling systems with heat recovery Display The dehumidifiers with heat recovery of high efficiency series GHE were designed to provide dehumidification and fresh air in a residential area with very high energy efficiency, combined with radiant cooling systems. The units have been designed to grant the dehumidification either under conditions of thermally neutral air or in terms of air-cooled, managing small air flow thus avoiding annoying tiny air currents typical of traditional air conditioning systems. The units consist of a direct expansion cooling system combined with a cross flow heat exchanger highly efficient, designed for heat recovery and air exchange environment in compliance with applicable regional and national lows. Versions All units are supplied with double condenser (the first is an air condenser, the second is a water one) and of a logic which allows the dehumidification with neutrum air or with cooled air. Accessories HYGR: Remote mechanical hygrostat + thermostat (WZ versions only) PCRL: Remote mechanical hygrostat. RGDD: Built in electronic temperature-humidity sensor. INSE: Serial interface card RS485. FAEL: High efficiency electronic air filter H0.

GHE Deumidificatori Dehumidifiers for con radiant recupero cooling di calore systems ad altissima with heat efficienza recovery Models GHE Useful dehumidification capacity (from the net hygroscopic content of the external air) () Total cooling Power (latent + sensible) () Recovered winter heating power (2) Efficency winter recovery (2) Efficency summer recovery () Power supply Compressor absorbed power () Supply fan absorbed power: minimum nominal maximum Return fan absorbed power Supply fan nominal useful prevalence Return fan nominal useful prevalence Min-max coil water flow Min-max water pressure drop Outdoor air flow Supply air flow Coolant type Sound power level (3) Sound Pressure Level (4) Weight GHE25 GHE50 l/24h 30, 6,8 W 380 2820 W 950 850 % 90% 90% % 70% 70% V/Ph/Hz 230//50 230//50 W 340 480 W 0 30 86 30 60 30 W 22 43 22 44 68 Pa 50 40 50 40 Pa 50 40 50 40 l/h 50-250 400 200-350 600 kpa 38 35 m 3 /h 80 30 40 250 m 3 /h 30 260 250 500 R34a R40A db(a) 47 52 db(a) 39 44 Kg 60 80 Performance refer to the following conditions: () Room Temp. 26 C; 65% RU; Ambient Temp. 35 C; 50% RU; System volume 30 m3/h; Water IN 5 C, Water Flow 250 l/h. (2) Ambient Temp. -5 C; 80% RU; Room Temp. 20 C; system at maximum. (3) Sound Power level according to ISO 964. (4) Sound Pressure level measured at mt from the unit in free field conditions according with ISO 964, at the normal working conditions. Typical installation Supply air flow Exhaust air intake GHE Recirculating Air Exhaust air intake Supply air flow Exhaust air intake Supply air flow

GHE Dehumidifiers for radiant cooling systems with heat recovery Frame All units are made from hot-galvanised thick sheet metal, to ensure the best resistance against the corrosions. The frame is self-supporting with removable panels. The drip tray is present standard in all units. Refrigerant circuit The refrigerant circuit is made by using international primary brands components and according to ISO 97/23 concerning welding procedures. The refrigerant gas used in these units is R34a for the model 25 and R407C for the models 50. Compressor The compressor is alternative for model 25 and rotative type for model 50., equipped and thermal overload protection by a klixon embedded in the motor winding. It s mounted on rubber vibration dampers to reduce the noise. Heat exchangers The heat exchangers are made of copper pipes and aluminium fins. The diameter of the copper pipes is 3/8 and the thickness of the aluminium fins is 0, mm. The tubes are mechanically expanded into the aluminium fins to improve the heat exchange factor. The geometry of these condensers guarantees a low air side pressure drop and then the use of low rotation (and low noise emission) fans. All the units have a stainless steel drip tray. Besides this, each evaporator is supplied of a temperature probe used as automatic antifreeze probe. Fans The supply fan is centrifugal type, double inlet with forwards blades, with EC Fan motor directly connected. The exhaust fan is plug fan type with backwards blades, with EC fan motor directly connected. Air filter Comes with the unit is built in removable filter media summary execution for differentiated waste disposal, G4. Heat recovery Hexagonal cross-flow heat recovery with PVC plates, high efficiency (90%). Adjustment trimmers Used during calibration of fans air flow depending on the ducts pressure drop. Microprocessor All GHE units are supplied with an advanced software for the complete control of the hydronic and air distribution side. The software can manage: - The management of the operation according to a probe of temperature and humidity. - Activation of the dehumidification based on the pre set humidity conditions. - Activation of of winter or summer sensible load integration, according to the summer or winter set point - Management of supply air temperature through discharge limit probe sensor (standard). - Modulating valve for the proper management of the water battery power - Ventilation Management directly from built-in timer in the microprocessor (optional). - Management damper - Machine Allarm display - Supervisor and BMS connection through serial card RS485 (Optional) a/o XWEB Module (Optional). - Clogged filters management (optional). - Antifreeze management. - Summer/Winter commutation. Main components 3 7 2 3 5 4 5 2 9 8 6 0 7 6 8 4 Air filter 0 2 Pre-Cooling coil 3 Evaporator 2 4 Compressor 3 5 Air Condenser 4 6 Solenoid Valve 5 7 Supply fan with EC 6 8 Dryer Filter 7 9 Body rolling 8 Water condenser Exhaust fan with EC motor High efficiency cross-flow heat recovery Return motorized damper WC exhaust air Fresh air Electrical Panel Modulating 3-way valve

GHE Deumidificatori Dehumidifiers for con radiant recupero cooling di calore systems ad altissima with heat efficienza recovery Refrigerant circuit functioning principles The functioning of the dehumidifier model GHE is as follows: the fan takes the air humid from the ambient through the fan (7) and it s made go through the filter () and the cross-flow heat (2) pre-cooling water coil (2) where it s cooled and brought to a condition closed to saturation. Now it passes through the evaporating coil (3) where it s fatherly cooled and dehumidified. At this time the functionality mode may be. The air passes now through the condensing coil (5) where it s post heated (with a constant humidity) and in cooling, when the solenoid valve (6) open where it s reported to the required conditions. Dehumidification with neutral air : The cooling system works partially in the water through the heat exchanger (0) and partially in the air with the heat exchanger (5) which will then make a post-heating at constant humidity blowing air in in the room in thermally neutral conditions. Direct Expansion + Water Coil Dehumidification with cooling: The cooling circuit, in this case, performing works 00% of the condensation in the water through the heat exchanger (0), the heat exchanger (5) is intercepted by the valve (6) and the air supplied in the room is the same as leaving the evaporator coil (3), cold and dried. Compressor Recirculation damper EC Fan adjustable trimmer Filter Control panel with display Hight Efficency Heat Recovery Supply Fan with EC motor Exhaust Fan with EC motor Plate Exchanger Aeraulic circuit functioning principles: GHE 25 units can operate with a flow rate of outdoor air from 80 to 30 m 3 /h (40 to 260 m 3 /h for the model GHE 50), to ensure sufficient supply air changes in the room having a variable volume by 260 m 3 (0.5 vol / h) to 460 m 3 (0.3 vol/h), in compliance with regional and national regulations. The air flow rate of discharge can vary from 80 to 30 m 3 /h (40-260 m 3 /h for the model 50) in the winter mode, and is fixed to 260 m 3 /h (500 m 3 /h for the model 50) in summer mode. The cross-flow heat exchanger of high efficiency is designed to ensure a recovery rating of 90% in terms of air temperature -5 C and air temperature 20 C. The stale air is expelled from the envi- ronment by the fan (), while the outside air is sucked through the fan (2). The proper balance of air flows is ensured by the damper (3) that handles both the balance of flows of air that the air flow recirculation summer. Return Air Return Air W.C. 3 (max. 50% 2 Supply Air 00%

GHE Dehumidifiers for radiant cooling systems with heat recovery SUMMER OPERATION (COMPRESSOR ON) Whit this selected mode the unit renews the ambient air with the outside through the heat exchanger for high efficiency, air flow is increased so as to allow operation of refrigerant circuit; for this purpose the r recycling damper will be open, the supply fan is operated at maximum capacity and the unit works with external air and partial recirculation. THE POSSIBLE FUNCTIONS IN THIS CONFIGURATION ARE: - Renewal + Air Dryers neutral: The condensing unit partially in air and partially in the water through the condenser plate, obtaining dry air and thermally neutral. - Renewal + Dehumidification with cooling: The unit operates with 00% of the condensation water, obtaining dry and cooled air. Return Air Return Air W.C. Supply Air 00% WINTER OPERATION AND MIDDLE SEASON (COMPRESSOR OFF) Whit this selected mode, the unit renews the ambient air with the outside through the heat exchanger of high efficiency. The air flow is reduced to the value required by the standard (0.3 0.5 vol/h), the recirculation damper is closed and the unit operates with 00% fresh air. THE POSSIBLE FUNCTIONS IN THIS CONFIGURATION ARE: - Renewal with heated air: The compressor is switched off, the battery can be supplied with hot water from radiant system. (even due to the high efficien- cy of the heat exchanger, is able to obtain a supply air temperature 7 C, without using hot water and ambient air temperature of -5 C), and behaves like a normal air handling with recovery. Return Air W.C. Supply Air 50%

GHE Dehumidifiers for radiant cooling systems with heat recovery Versions GHE Code GHE25 GHE50 Microprocessor control Flow meter Modulating 3-way valve Supply & Return EC fans G4 air filter Adjustable Trimmers High Efficency Heat Recovery Remote control Panel PCRL Thermo- Mechanical remote Hygrostat HYGR Umidity and Temperature electronic probe sensor RGDD Serial interface card RS485 INSE High efficiency electronic air filter FAEL Standard, Optional, Not available. Recovery Mix flow Pre-Cooling Evaporator Condenser (if active) Mod. 25 50 A (mm) 258 400 B (mm) 55 370 C (mm) 732 835 For more details ask technical documentation to info@aerfor.com Aerx.dp.ghe.gb.002.5 Aerfor S.r.l. Via dell Industria n. 5A 35020 - Brugine - Padova - Italy Tel +39 049 9730045 e-mail : info@aerfor.com Pec: aerfor@registerpec.it P.IVA 02703580304 R.E.A. : RO-59632 www.aerfor.com