BENSON LINEAR RADIANT TUBE

Similar documents
BENSON GAS UNIT HEATERS

BENSON VARIANTE 2 RANGE

U tube models PTU 09, 12, 15, 25, 30, 35, 40, 45. single linear tube models PTS 09, 12, 15, 25, 30, 35, 40, 45

INSTALLATION & SERVICING MANUAL FOR BENSON PV TUBULAR CABINET HEATER NATURAL GAS (G20 I 2 H), PROPANE GAS (G31 I 3 P)

BENSON VARIANTE 2 RANGE

INSTALLATION & SERVICING MANUAL FOR HARRY TAYLOR VARIANTE² BI DIRECTIONAL NATURAL GAS (G20 I 2 H), PROPANE GAS (G31 I 3 P)

INSTALLATION & SERVICING MANUAL FOR BENSON GAS FIRED CABINET HEATER NATURAL GAS (G20 I 2 H), PROPANE GAS (G31 I 3 P)

BENSON VARIANTE 2 RANGE. Headin BI DIRECTIONAL NATURAL GAS (G20 I 2H ) PROPANE GAS (G31 I 3P ) TUBULAR HEATER

BENSON CABINET HEATER

BENSON HEATING INSTALLATION OPERATION AND SERVICING MANUAL

HERRINGBONE HB COMBINED FLUE SYSTEM

INSTALLATION & SERVICING MANUAL FOR BENSON VARIANTE² TUBULAR HEATER NATURAL GAS (G20 I 2 H), PROPANE GAS (G31 I 3 P)

BENSON GUHA/GUHC. Headin RANGE. (NATURAL GAS FIRED UNIT HEATER) g I N S T A L L A T I O N C O M M I S S I O N I N G

OPTIMA RADIANT TUBE HEATING SYSTEMS. Operation, maintenance and servicing manual

INSTALLATION & SERVICING MANUAL FOR BENSON EVRD EXTERNAL TUBULAR HEATER NATURAL GAS (G20 I 2 H), PROPANE GAS (G31 I 3 P)

BENSON OIL UNIT HEATER 2 RANGE

ASSEMBLY, INSTALLATION & SERVICING MANUAL OUH SERIES OIL UNIT HEATER

FLUEBOOST. flueboost 350 gas fire model

INSTALLATION & SERVICING MANUAL FOR HARRY TAYLOR OUH² OIL UNIT HEATER

Forced draught gas burner

Jetaire. Automatic & Manual (Propane) Heaters Operating and Maintenance Manual Models - LG 90M -150M/A - 280M/A - 350A

100 FLUEBOOST

CARVER CASCADE 2 & CASCADE 2 GE CARAVAN WATER HEATER INSTALLATION INSTRUCTIONS LEAVE THESE INSTRUCTIONS WITH THE USER

GAS FIRED AIR CURTAIN AB 175, AB 225

GAS FIRED AIR CURTAIN AB 175, AB 225

Osprey 2 CFL

INSTALLATION AND OPERATION INSTRUCTIONS OVERHEAD RADIANT TUBE HEATERS

INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS BG 2000-S (V13) RU PL DE IT ES NL EN 1 662Y0600 A

MAINTENANCE AND SERVICE GUIDE

Herringbone Linked Flue System

LAE10 LFE10. Use. Series 02

Servicing manual. Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C /2002 GB(EN) For trade use

INSTRUCTION MANUAL FOR OIL BURNER MODELS

These Appliances must be installed and serviced by a competent person as stipulated by the Gas Safety (Installation & Use) Regulations.

INSTRUCTION MANUAL FOR OIL BURNER MODELS

Servicing manual. 600 Series - 11S / 19S / 24S / 24C. Wall-mounted condensing gas boiler. For trade use

ProCon Streamline Gas Condensing Boiler. Installation and Operating Manual.

Installation and Operating Manual Drying Cabinet

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL

EUROBOX SERIES TYPES CM... SM... MM...

CODE MODEL TYPE PRESS 60 N 616 T PRESS 60 N 616 T80

NXM2G Installation and Operating Manual

RS/UHC / UF RS/UHC-2 / 2UF

AB RANGE GAS FIRED ROOM SEALED AIR CURTAIN INSTALLATION AND OPERATING MANUAL

EDENA CLASSIC E. Model : kw INTALLATION AND SERVICING INSTRUCTIONS. Gas Fired Floor Standing Boiler. Réf. : CH I EN 09/05

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

I n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d. Model code: BORA600

INSTALLATION AND OPERATION INSTRUCTIONS Double Linear OVERHEAD RADIANT TUBE HEATERS Models: PTDSL 15, PTDSL 25, PTDSL 30, PTDSL 35, PTDSL 40, PTDSL 45

TC MODULE (FFD) (with Gas Hob)

BG2000S PRE-MIX GAS BURNER

INSTALLATION & SERVICING MANUAL FOR REZNOR OIL FIRED CABINET HEATER WARNINGS

INSTRUCTION MANUAL FOR OIL BURNER MODELS

Flame Safeguards LFE10. Building Technologies HVAC Products

Light oil - kerosene burner

Light oil / kerosene burner

PowerVent. Installation manual (GB) English. Store this document in a safe place UK

AMBIRAD VISION VS RANGE RADIANT TUBE HEATERS SERVICING & COMMISSIONING MANUAL

All Heaters Part L2B Compliant. Technical Data External Oil and Gas Cabinet Heaters. For Models. EVD Vertical Ducted EHD Hortizontal Ducted

Mikrofill Ethos Condensing combination boiler

GAS FIRED CONVECTION HEATERS WITH FAN GHIBLI SERIES Models Technical information

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

MEC MEC C

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

INSTALLATION AND OPERATION INSTRUCTIONS OVERHEAD RADIANT TUBE HEATERS

GECE cm touch control ceramic hob. GECE cm touch control ceramic hob

VPC Gas Cabinet Heater Range

VPC Gas Cabinet Heater Range Architects of your environment. heating ventilation air conditioning

GAS FIRED ATMOSPHERIC ELECTRONIC VERSION kw

MULTIPLEX SELF RECUPERATIVE gas burner

Jetstreme. Floor Standing Oil Boiler. Jetstreme 55

UV Flame Supervision System

COMMERCIAL GAS AND ELECTRIC STACKED WASHER/ DRYER INSTALLATION INSTRUCTIONS

MULTIPOINT BF Gas Fired Balanced Flue Water Heater

Domestic Gas Safety Assessments (DGA) Competency Assessment Certification Scheme for Registered Gas Installers

TEMPRA. Wall Mounted Fan Flue System boiler. Wall mounted fanned flue boiler INSTALLATION AND USE INSTRUCTIONS. Appr. nr. B A - CE 0063 AQ 2150

USER MANUAL. 60cm, 3 burners, Hob AKC 630

Compact. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

HHG610SS 60cm 4 burner gas hob. HHG710SS 70cm 5 burner gas hob

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

AMBIRAD VISION VS RANGE RADIANT TUBE HEATERS SERVICING & COMMISSIONING MANUAL

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

HOT AIR GENERATOR WITH GAS BURNER NA11.45 A GGS. Installation Operation Commissioning Maintenance

Safety. Operating instructions Ionization pilot burners ZAI, ZMI, ZKIH DANGER. Contents WARNING CAUTION Edition 12.11

BACE cm ceramic electric cooktop GECE cm ceramic electric cooktop

INSTALLATION & USER INSTRUCTIONS

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

Proline GAS HOB Model TCG40IX Instruction Book

Heat 45 & 55. User Instructions FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

BAXI BOSTON ALL MODELS FLOOR STANDING OPEN FLUE (OF) CENTRAL HEATING BOILERS INSTALLATION AND SERVICING INSTRUCTIONS. GAS TYPE G20 (Natural Gas)

MULTIPOINT FF Room Sealed Fan-Assisted Water Heater

LGA... Gas Burner Controls. Siemens Building Technologies Landis & Staefa Division

PowerVent. Installation manual (GB) English. Store this document in a safe place UK

BWTC6510GL Cooker Hood 60 cm Glass cooker hood in stainless steel. BWTC9510GL Cooker Hood 90 cm Glass cooker hood in stainless steel

Baxi Brazilia F5, F5S & F8S

BWT6.3GL Cooker Hood 60 cm Glass chimney hood

Compact HE. High efficiency combi boiler. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

GAS-FIRED AIR HEATERS MEC - MEC C SERIES Models Technical information

Flame Safeguards LFE10. Building Technologies HVAC Products

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

INSTALLATION GUIDE Dual Fuel Ranges

Transcription:

BENSON LINEAR RADIANT TUBE Natural or Propane (Gas fired) I N S T A L L A T I O N C O M M I S S I O N I N G S E R V I C I N G U S E R I N S T R U C T I O N S September 2001

CONTENTS Page Compliance Notices 3 Certificates of Conformity 3 General Requirements 4 Burner Data 5 General Arrangements 6 Burner Assembly 7 Heat Exchanger Assembly & Dimensions 8 Support Assembly & Tube Construction 9 Roof & Wall Installation 10 Gas Supply General 10 Electrical Supply / Connection 11 Installation Diagrams 12 Gas & Electrical Layout 13 Controls Wiring 14 Electrode Positions 15 Commissioning & Start up 16 Fault Finding Guide 17 Any reference made to Laws, Standards, Directives, Codes of Practice or other recommendations governing the application and installation of heating appliances and which may be referred to in Brochures, Specifications, Quotations, and Installation, Operation and Maintenance manuals is done so for information and guidance purposes only and should only be considered valid at the time of the publication. Benson Heating cannot be held responsible from any matters arising from the revision to or introduction of new Laws, Standards, Directives, Codes of Practice or other recommendations.

Compliance notices The Benson Gas Rad range of linear radiant tube heaters detailed herewith are manufactured for Benson Heating within a strictly controlled environment within the parameters of ISO9002 The Gas Rad range has been independently tested and assessed, and has been found to meet the Essential Requirements of the following European Directives. Gas Appliance Directive (90 / 396 / EEC) Machinery Directive (89 / 392 EEC) Low Voltage Directive(73 / 23 / EEC & 93 / 68 / EEC) Electromagnetic Compatibility Directive (98 / 336 / EEC & 91 / 31 / EEC) Product Liability Directive 65 / 374 / EEC) The manufacturer has taken reasonable and practical steps to ensure that Gas Rad range of Heaters are safe and without risk when properly used. These heaters should therefore only be used in the manner and purpose for which they were intended, and in accordance with the recommendations detailed herewith. The heaters have been designed, manufactured, assembled, inspected, and tested, with safety and quality in mind, there are certain basic precautions which the installer and user should be aware of, and they are strongly advised to read the appropriate sections of the information pack accompanying the heater, prior to installation or use. Benson Heating supports all new products being supplied to their customers with a comprehensive information pack; this clearly defines mandatory instructions for the safe installation, use, and maintenance, of the appliance(s). Where proprietary items are incorporated into Benson Heating products, detailed information and instructions are also provided as part of the information pack. It is the responsibility of the installer, owner, user, or hirer, of such products supplied by Benson Heating, to ensure that they are familiar with the appropriate information/manuals, supplied by the manufacturer, and that they are suitably aware of the purpose of the manuals and the safety instructions. In addition, operators must be suitably trained in the use of the appliance so as to ensure its continued safe and efficient use. Benson Heating has a commitment to continuous improvement, and therefore reserves the right to amend or change the specification of the Heater range subject to agreement from The Notified Body. Contained within the text of the manual, the words 'Caution' and 'Warning' are used to highlight certain points. Caution is used when failure to follow or implement the instruction(s) can lead to premature failure or damage to the heater or its component parts. Warning is used when failure to heed or implement the instruction(s) can lead to not only component damage, but also to a hazardous situation being created where there is a risk of personal injury. Certificates of conformity Declarations and Certificates are available upon request from the Quality Control Department at Benson Heating. Notified Body PIN Reference is 49AR1806 49AR1653 49AR1654

THE WARRANTY REGISTRATION AT THE REAR OF THIS MANUAL MUST BE COMPLETED AND RETURNED TO BENSON HEATING ON COMPLETION OF COMMISSIONING Warranty claims made without this condition being fulfilled will not be processed General requirements Caution Ensure that the gas service to the appliance carries the correct gas type and that the supply pressure is in accordance with the supply type and pressure stated on the appliance data plate. Installation, commissioning, and servicing must only be carried out by appropriately qualified and competent persons. Warning Unauthorised modifications to the appliance, or departure from the manufacturers guidance on intended use, or, installation contrary to the manufacturers recommendations may constitute a hazard. Note To ignore the warning and caution notices, and to ignore the advice from the manufacturer on installation, commissioning, servicing, or use, will jeopardise any applicable warranty, moreover, such a situation could also compromise the safe and efficient running of the appliance itself, and thereby constitute a hazard. The installation of the appliance must meet all the relevant European, national, and local criteria. Prior to installation the following points should be considered; a) The position of the heater for the optimum efficient distribution and circulation of warm air b) The position of the heater relative to the route of the flue c) The position of the heater relative to the supply of gas d) The position of the heater relative to the electrical services, wiring routes, and if appropriate, any additional controls. e) The position of the heater relative to the supply of fresh air f) The position of the heater relative to potential stratification / circulation problems, which generally occur at higher levels and which may be overcome through the provision of a suitable de-stratification unit. g) The position of the heater relative to service and maintenance requirements Caution The heater must not be installed within an area where the conditions are unsuitable, e.g. where the atmosphere is highly corrosive, has a high degree of salinity, or where high wind velocities may affect burner operation. Suitable protection should be provided for the appliance when it is located in a position where it may be susceptible to external mechanical damage from; for example, fork lift trucks, overhead cranes etc. Mounting Heights The Minimum installation height of the radiant tube from floor level is not less than 4 Mtrs The minimum installation height from combustible material should be not less than 1.5 Mtrs below and 60 Cms to the sides

Technical Data Model GRH-L 30/12 35/12 40/12 45/18 Input kw 30 35 40 45 Burner Type Atmospheric Gas G20 m 3 /h 2.85 3.33 3.81 4.28 Consumption G31 kg 3 /h 2.14 2.50 2.85 3.21 Gas connection Ins ½ ½ ½ ½ Head pressure G 20 mbar 8.5 Inlet pressure G 20 mbar 20 Gas Press switch G20 mbar 9-10 Nozzle size G20 No 3 X 2.8 4 X 2.8 4 X 2.8 4 X 2.8 Head pressure G31 mbar 36 Inlet pressure G31 mbar 37 Gas Press switch G31 mbar 30-31 Nozzle size G31 No 3 X 1.55 4 X 1.45 4 X 1.55 4 X 1.65 Electricity supply Volts 230v/1ph/50Hz Power consumption Watts 56 Electrical Power Amps 0.5 Burner heads No 3 4 4 4 Weight Kg 108 108 147 147 Length of pipes mtrs 12 12 12 18 Exchanger tube Ø mm 89 Air intake Ø mm 80 80 80 80 Flue Ø mm 80 80 80 80 Combustion Air m 3 /h 60.00 75.00 80.00 90.00 Model GRH-L-2 30/12-2 35/12-2 40/12-2 45/18-2 Input kw 30 35 40 45 Burner Type Atmospheric Gas G20 m 3 /h 1.9-2.85 2.85 3.33 2.85 3.81 2.85 4.28 Consumption G31 kg 3 /h 1.42 2.14 2.14 2.50 2.14 2.85 2.14 3.21 Gas connection Ins ½ ½ ½ ½ Head pressure G 20 mbar 8.5 Inlet pressure G 20 mbar 20 Gas Press switch G20 mbar 9 10 Nozzle size G20 No 3 X 2.80 4 X 2.80 4 X 2.80 4 X 2.80 Head pressure G31 mbar 36 Inlet pressure G31 mbar 37 Gas Press switch G31 mbar 30 31 Nozzle size G31 No 3 X 1.55 4 X 1.45 4 X 1.55 4 X 1.65 Electricity supply Volts 230v/1ph/50Hz Power consumption Watts 56 Electrical Power Amps 0.50 Burner heads No 3 4 4 4 Weight Kg 108 108 147 147 Length of pipes mtr s 12 12 12 18 Exchanger tube Ø mm 89 Air intake Ø mm 80 80 80 80 Flue Ø mm 80 80 80 80 Combustion Air m 3 /h 60.00 75.00 80.00 90.00

General Arrangement 1 Aluminium reflector 9 Reflector Support Bracket 2 Combustion air intake 10 Exchanger Pipe 3 ½ Gas Connection 11 Reflector Spring Clips 4 Burner Access Cover 12 Flue Spigot 5 Electrical Plug 6 pole 13 Fan Access Cover 6 Mains socket 7 Access Cover Locks 8 Mains Plug

Burner External Dimensions Fan External Dimensions

Burner Assembly and Fan Assembly viewed with assemblies upside down. 1 Lockout Neon (red) 1 Air Pressure Switch 2 Gas Manifold 2 Fan Casing 3 Burner Heads 3 Fan Motor 4 Gas valve 4 Plug 6 Pole 5 Operating Neon (green) 5 Access Lid 6 Control Box 7 Gas Connection 8 Access Lid 9 Electrodes

Heat Exchanger Assembly Dimensions A Reflector Support Brackets GRHL 30/12 GRHL 35/12 GRHL40/12 GRHL 45/18

Radiant Linear Tube Assembly Instructions Assemble the exchanger pipes as shown inserting the ceramic fibre gasket between the pipe joints. Ensure that the first tube on the burner side, is the pipe having a painted red flange. Secure the pipes together with 8mm fittings ensuring that the insides are clean. Fit gaskets to the burner assembly casing and fan assembly casing ensure that when fitting in position on to the tubes that the burner and fan access doors are facing downward, and the intake and flue pipe spigots face upwards Secure both burner and fan to the exchanger pipes to complete the assembly. Bracket assembly Bend the tabs on the reflector support brackets at 90 deg 2 outer tabs one side and the centre tab to the opposite side. Repeat this operation on all the reflector brackets (Bracket A) and clamp the bracket to the tube with the U clamp and secure with the 6mm fixings provided. Assembly of Reflectors Remove the protective film from the reflectors Place the reflectors in the assembled brackets and overlap them slightly Secure with the self tapping screws Then using the spring clips provided secure the reflectors to the brackets by stretching the wire over the reflector and secure each end to the Bracket A.

Diagrams showing support assembly INSTALLATION OF EXHAUST CHIMNEY THROUGH ROOF Installation type B 1) After securing linear tube in position drill a 80Ø hole in the roof for the chimney (see illustrations) 2) The total extension for the flue pipe should not be longer than 4mtrs if it is necessary to insert a bend calculate 1mtr for each bend the diameter of the exhaust should not be less than 80mm. 3) Install the flue pipe in the hole previously drilled ensure that the flue pipe is adequately sealed to prevent water ingress 4) Ensure all flue connections are sealed, if using flexible flue pipe ensure that the correct fittings are used. 5) Ensure a cowl is fitted to the end of the flue INSTALLATION OF EXHAUST CHIMNEY THROUGH WALL Installation type B 1) After securing linear tube in position drill an 80Ø hole through the wall 2) The total extension for the flue pipe should not be longer than 3.5mtrs if it is necessary to insert a bend calculate 1mtr for each bend, the diameter of the exhaust should not be less than 80mm 3) Install the flue pipe ensure that all the flue connections are sealed, if using flexible flue pipe ensure that the correct fittings are used. 4) Ensure a cowl is fitted to the end of the flue 5) If using flexible flue pipe ensure that the correct fittings are used. INSTALLATION TYPE B INSTALLATION TYPE B Flue using Rigid pipe Flue using Flexible pipe

Roof Installation Hook the support chains on to the roof fittings previously fabricated on site. The chains should be fixed 45cm apart on the exchanger sections and on the Burner and Fan Units. Raise the Linear Tube Assembly and secure to the chains, After securing the Linear Tube to the roof fixings 2 x 80 Ø holes should be cut in the roof for the air inlet and flue pipes. The air inlet and flue pipes should not exceed 4 mts and should not normally contain any bends or restrictions. If it is necessary to include a bend each bend should be regarded as a metre length. Ensure the air intake and flue are sealed through the roof to prevent any water ingress And ensure a cowl is fitted to both terminals. Gas supply general The Benson range of radiant tube gas fired heaters are all manufactured and pre-set for use with natural gas classified under the following categories, based upon the destination of the heater I 2H, I 2L, I 2Es, I 2E(R)B, I 2Esi, The heater must be compatible with the gas supply, and each heater must be installed with a separate approved isolating gas cock positioned adjacent to and upstream of the union between the service pipe and the heater. The gas supplier should have been contacted to confirm that the supply feed (pipework and metering) is capable of delivering the required dynamic volume of gas, thereby ensuring that the minimum burner pressure can be achieved. Consideration should have also been given to the pressure drop on single and multiple heater installations, and the affect that such installations will have upon other plant sharing the gas supply. If it is necessary to fit a gas booster, the controls must include a low pressure cut-off switch which must be fitted on the supply side of the booster. It is also a requirement that the gas supplier is contacted prior to the fitting of the unit. Note Reference to the Institute of Gas Engineers publication UP-1 and UP-2 together with BS6891 is strongly advised. Service and Installation pipework must be of a diameter equal to or greater than the inlet connection on the heater, all joints must be sealed using an approved sealing compound, and the system purged and tested for soundness. Gas Installation/connection Service pipework must terminate at an approved gas cock, and be adjacent to the position of the heater. The connection to the heater can be made by way of an approved flexible coupling,. Threaded connections must comply with ISO288/1 of ISO 7/1, further information concerning the accepted practice in European countries is detailed in the June 1995 version of pren 1020 annex A7

Electrical supply Wiring external to the Radiant Tube heater must be installed in accordance with any local, national, and European regulations, as well as meeting the appropriate requirements of IEE regulations. The means of connection to the main electrical supply must allow for complete electrical isolation of the heater. Icn 6KA Vn 400 Ian 0.03A Furthermore, the supply should only be used to serve the heater itself and no other plant or equipment. The position of the isolation switch must be such that it is adjacent to the heater and easily accessible at all times. In addition, the isolator itself must have a contact separation of not less than 3mm as per BS5991 clause 20.2. The Control Fuse ratings are detailed on the appliance data plate. Warning Ensure that the electric and gas supplies are turned off before any electrical work is carried out on the heater. Ensure that wiring cannot make contact with any surfaces liable to be subject to high temperatures or where the insulation of the wiring could be impaired as a result of such contact. All Benson Gas Rad Heaters must be earthed. Caution The main electrical supply must not be switched off or disconnected as a method for stopping the heater, the exception to this is in an emergency, or during servicing, when the heat exchanger has been allowed to cool sufficiently to prevent any damage from occurring. Claims for damage will not be considered if they have resulted from incorrect wiring or the incorrect use of the heater. Electrical Installation/connection Benson Radiant Tube heaters are 230V 50Hz 1PH It is recommended that reference is made to the wiring diagrams contained within this manual prior to installation or connection to the supply. The electrical supply must be as specified and suitable for the heater, and must be run within conduit to a point adjacent to the heater, and be terminated to provide an isolation point that will prevent remote or inadvertent activation. Cables, conduit, and fittings that are used to make the connection between the isolator and the heater must conform to the appropriate IEE regulations. All radiant tubes are supplied fused and pre-wired, all must be earthed.

WIRING DIAGRAM OF CONTROL PANEL WITH TWO THERMOSTATS ON/OFF KEY L1 Power supply 230/1ph/50Hz N Neutral PE Earth IG Fused isolator ID Differential switch Ign Day Night Manual Switch T1 T2 Thermostat B1 B 2 Burners GL1 GL2 Probe IZ1 IZ2 Zone switch KT1 KT2 Control Relay MAN Manual Override WIRING DIAGRAM OF CONTROL PANEL WITH TWO THERMOSTATS TWO STAGE KEY L1 Power supply 230/1ph/50Hz N Neutral PE Earth IG Fused isolator ID Differential switch Ign Day Night Manual Switch T1 T2 Thermostat B1 B2 Burners GL1 GL2 Probe IZ1 IZ2 Zone switch KT1 Control Relay 1 st Stage KT2 Control Relay 2 nd Stage MAN Manual Override

WIRING DIAGRAM OF CONTROL PANEL WITH TWO THERMOSTATS AND CLOCK ON/OFF KEY L1 Power supply 230/1ph/50Hz N Neutral PE Earth IG Fused isolator ID Differential switch TI Time Clock Ign Day Night Manual Switch T1 T2 Thermostat B1 B 2 Burners GL1 GL2 Probe IZ1 IZ2 Zone switch KT1 KT2 Control Relay MAN Manual Override WIRING DIAGRAM OF CONTROL PANEL WITH TWO THERMOSTATS AND CLOCK TWO STAGE KEY L1 Power supply 230/1ph/50Hz N Neutral PE Earth IG Fused isolator ID Differential switch Ti Time Clock Ign Day Night Manual Switch T1 T2 Thermostat B1 B2 Burners GL1 GL2 Probe IZ1 IZ2 Zone switch KT1 Control Relay 1 st Stage KT2 Control Relay 2 nd Stage MAN Manual Override

Gas Supply Connections 1 Burner 2 Flexible Pipe 3 Isolating Valve 4 Mains Gas Supply Sample Electrical Layout

CONTROL PANEL DESCRIPTION Electrical control panels can be supplied for operation with 1-2 thermostats or 3-10 thermostats on request, to ensure that the heating system is both comfortable and cost effective. Supplied in a Control Box with an IP 65 Rating with the following :- Two pole isolating switch 1 2 or 3 10 stats Time clock

Electrode positions The illustrations below show the correct positioning of the electrodes in the holder block. Ensure that the gap is set as per dimensions shown and the ceramic insulation is not cracked or broken A Ignition Electrode B Fixed earth electrode C Detection Electrode B Fixed earth electrode B Fixed earth electrode

Commissioning Pre-test Check to ensure electrical safety, and inspect and check the installation, testing for leaks. (a) Ensure that the electrical supply is turned off. (b) Ensure that the gas supply is turned off. (c) Check that all panels and fasteners are secure and in place. (d) Check that the heater is installed so that it is square and that the support is adequate. Start up a) Switch on Electrical supply b) Turn on Gas supply c) Connect manometer to test point d) The power lamp will illuminate and the fan will start, for a short period the lockout indication lamp will also illuminate, e) The fan will pre purge for 30 seconds and the 5 second ignition sequence will then take place f) The flame will be detected by the flame probe the lockout will extinguish and the heater will run the power light will remain illuminated g) Adjust burner gas pressure on gas valve to settings advised on data sheet h) Check combustion figures with gas analyser

Gas valve 1 Gas inlet pressure test point 2 Gas head pressure test point 3 Gas pressure adjustment screw Gas Valve Hi / Lo 3 Gas pressure adjustment screw 2 nd stage 4 Gas pressure adjustment screw 1 st stage

Heater at lockout Switch off heater for a few seconds then restore power Check there is power to the unit Fan Motor not working Check heater controls Check fan is not blocked or restricted Ensure there is sufficient gas pressure to operate the gas pressure switch PG Motor runs but heater at lockout Check air pressure switch is functioning correctly Replace Control Box Ignition takes place but burner does not light Check gas solenoid is operating correctly Check that the ignition electrode is correctly positioned and not cracked

Check that the burner supply live and neutral wires are connected correctly Burner lights but ignition continues to spark Check that the detection electrode is not touching the burner body Check that the detection electrode setting dimension is correct Check that the gas inlet and head pressure is correct as per data table Check that the diaphragm plate has been installed on the fan correctly Combustion results unsatisfactory Check that the flue and air inlet pipes do not exceed maximum lengths see page 10 Check that the flue and air inlet pipes are of the correct diameter see page 10 Check that the flue and air inlet pipes are free from obstruction

Servicing It is recommended that the Gas Rad is serviced annually, however in exceptional conditions more frequent servicing may be required. It is important to ensure that the heaters are suitably suspended and that heavy items and ladders are not rested against the heaters. Turn off and disconnect the electrical and gas supplies