YORK COUNTY DEPARTMENT OF FIRE SAFETY BUILDING PLAN REVIEW REQUIREMENTS

Similar documents
Defend In Place 2012 IFC Overview of Institutional Occupancies

2018 IFC Update. Based on the 2018 International Fire Code, (IFC ) Goal. Objectives. Content

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures

New Construction Fire Inspection Process

Business Fire Inspection. City of Guadalupe

City of South Salt Lake Fire Code Training Exiting, Egress Systems and Egress Control

Is the address of your property clearly visible and marked in large numbers that can be easily seen from the street?

Fire and Life Safety Review Form

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION CHECKLIST

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST

INTERIOR FINISH REVIEW

FIRE SERVICE FEATURES

PROPOSED CODE CHANGES FOR REVIEW BY THE FIRE CODE ACTION COMMITTEE

SAFETY. USE OF SAFETY CHECK LISTS A safety check for compliance with current regulations should be performed yearly.

To expedite the plan review and inspection processes, please refer to the information below.

Item Referenced and Amendments Building 1 Building 2 Analysis, Review and Remarks. Page 1 of 15

ICC CODE CORNER 2015 International Fire Code

OCCUPANCY INSPECTION FORM

FIRE PREVENTION OFFICE Placer Hills Fire Protection District NEW PROJECT GUIDELINES

Requirements for the protection of High-Piled Combustible Storage (HPCS) Effective Date: January 2011

CHAPTER 56 EXPLOSIVES AND FIREWORKS SECTION FIREWORKS 1.4G RETAIL STORAGE, DISPLAY, AND SALE

H BUTCH BROWNING FIRE MARSHAL BUILDING REHABILITATION

Residential-based Care Facility R-4 Guideline

Report to Adhoc Health Code change proposal regarding locking arrangements From John Woestman, BMHA

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD

Rocky Mountain Fire Protection District 4390 Eldorado Springs Drive Boulder, CO

Common Fire Code Violation Checklist. Listed are some of the most commonly found fire code violations and should not be considered as all inclusive.

Winnipeg Fire Department Fire Prevention Branch

Osceola County Department of Fire Rescue and Emergency Medical Services

Large Family Daycare Guideline

For additional information regarding Group I occupancies please call (951)

Fire Sprinkler Plan Submittal Form

PLAN REVIEW SUBMITTAL GUIDE

GUIDELINES FOR INSPECTING GROUND BASED SPARKLING DEVICE (GBSD) RETAIL SALES FACILITIES

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

Table of Contents CHAPTER 10 ADMINISTRATIVE RULES FOR CERTIFICATION OF CHILD CARE FACILITIES FIRE STANDARDS FOR FAMILY CHILD CARE HOME

New Facilities. Minimum Requirements

Black Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment

Residential-based Care Facility R2.1 Guideline

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry

FIRE PROTECTION SYSTEMS

Business License Pre-inspection Checklist

SACRAMENTO FIRE DEPARTMENT FIRE PREVENTION DIVISION FIRE DEPARTMENT DEVELOPMENT SERVICES UNIT CONTRATOR INFORMATION PACKET

South Davis Metro Fire Agency

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

Life Safety - Means of Egress/Exits NFPA 101

SPECIAL AMUSEMENT OCCUPANCIES HAUNTED HOUSE, SCARE HOUSE OR MAZE

CHAPTER 7 ALTERATIONS LEVEL

Report on First Revisions with Statement June 2014 NFPA 101

TRI-LAKES MONUMENT FIRE PROTECTION DISTRICT

BUILDER S PRE-INSPECTION CHECKLIST

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline

Safety Tips for the Office

Denver Fire Department Fire Prevention Division

Residential Care Facilities Requirements

NFPA 101 Life Safety Code Culture change 2012

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

Balloting Version First Draft NFPA 101 Life Safety Code Proposed 2015 Edition

Chapter Nursing Homes

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

Section 5.0: HAZARDOUS MATEIRAL STORAGE TABLE OF CONTENTS. A. Regulations, Standards and References 2. B. Scope 3. C. Approvals and Listings 3

PROPOSED Houston Amendments to the 2015 International Building Code

TABLE OF CONTENTS ADOPTED FIRE CODES... 3 AFPD SERVICE AREA... 3 SITE AND DEVELOPMENT SUBMITTAL REQUIREMENTS... 4 PLAN REVIEW FEES...

M E M O R A N D U M. Diane Matthews, Administrator, Technical Projects. NFPA 101 First Draft Letter Ballot (A2014)

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

January 1, 2014 Mandatory Effective Date

FIRE INSPECTORS GUIDELINES FOR PLAN REVIEWS AND INSPECTIONS OF NEW CONSTRUCTION / ADDITIONS AND CHANGE OF OCCUPANCY

Retain. Retain. Retain. Board Advisory. Board Advisory. Retain. Disposition. (Statute, Rule, FBC, Industry)

INITIAL FIRE SAFETY ASSESSMENT

Educational Occupancies

Burien/Normandy Park Fire Department 900 SW 146 th ST PO Box Burien, WA BP (206) Fax (206)

Fort Bragg Fire and Emergency Services Division Fire Safety Survey For use of this form, see FB Reg 420-1, the proponent agency for this form is DES.

Are there any policies regarding outlets that contain USB ports?

2012 International Fire Code Significant Changes. IFC Background. Purpose IBC and 2012 NFPA 101 Significant Means of Egress Changes

Washoe County Department of Social Services

For additional information regarding R-3.1 residential care facilities please contact (951)

The one-half hour seminar in module 2 that follows, will complete the remainder of chapter 3, building planning, already begun in module 1.

GENERAL AREAS OF INSPECTION

Savard Labor & Marine Staffing, Inc. Fire Prevention Program Rev3/14

BUILDER S PRE-INSPECTION CHECKLIST

Construction and Development Guide

Plan Review Check List Fire Alarm System

2009 International Fire Code Errata. SECOND PRINTING (Posted April 6, 2010)

IFC Significant Changes from the 2009 to the 2015 Edition Tier 1

AUTOMATIC FIRE SPRINKLER SYSTEMS

FIRE SAFETY MAINTENANCE INFORMATION for Agricultural Livestock Structures

FIRE PREVENTION STANDARDS

The following are the Proposed Amendments to 2015 edition of the Life Safety Code (NFPA 101):

APPLICATION FOR Large Family Day Care Permit

Cannabis Business License Project Description

SAF-BCF SECOND REVISIONS WITH STATEMENTS

Riverside County Fire Department Office of the Fire Marshal Market St., Ste. 150, Riverside, CA Ph. (951) Fax (951)

FIRE EXTINGUISHER SPACING & INSTALLATION GUIDELINES

INITIAL FIRE ASSESSMENT REPORT (FAR)

Wausau Fire Department Inspection Violation Code Listing (Modified) All Applicable Records

Bold items are particular to the City of Euless

Nirmal Chandra Sinha. Supposed to complete(dd/ MM/YYYY) Comments after Physical Inspection

MINNESOTA STATE DEPARTMENT OF PUBLIC SAFETY

Short Term Accommodations Fire Code Requirements

Fire Department HEADQUARTERS Cathedral Oaks Road Santa Barbara, CA (805) FAX: (805) CODE SUMMARY

Transcription:

YORK COUNTY DEPARTMENT OF FIRE SAFETY BUILDING PLAN REVIEW REQUIREMENTS The York County Department of Fire Safety reviews all commercial building plan submittals for compliance with the 2015 International Fire Code and referenced standards. The following is a list of common code requirements which should be shown on the plans, if applicable. (This should not be considered all of the requirements and any applicable section of the 2015 International Fire Code should be documented). Post Occupancy The 2015 International Fire Code, section 1004.3 requires every room or space that is an assembly occupancy to have the occupant load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or the owner s authorized agent. Fire Alarm Plans The 2015 International Fire Code, section 907.1.2 requires shop drawings for fire alarm systems to be submitted for review and approval prior to system installation. Please submit fire alarm plans to this office for review and approval. Fire Alarm System 2013 NFPA 72 requires the following: Section 10.6.5.2.1 requires the location of the fire alarm branch circuit disconnecting means to be permanently identified at the control unit. Section 10.6.5.2.2 requires the system circuit disconnecting means to be permanently identified as to its purpose in accordance with the following: (1) FIRE ALARM for fire alarm systems (2) EMERGENCY COMMUNICATIONS for emergency communications systems (3) FIRE ALARM/ECS for combination fire alarm and emergency communications systems. Section 10.6.5.2.3 requires the fire alarm and/or signaling systems, circuit disconnecting means to have a red marking. Section 10.6.5.4 requires a listed breaker locking device to be installed. Section 10.6.10.1.1 requires batteries to be marked with the month and year of manufacture using the month/year format. Fire Alarm Monitoring The 2015 International Fire Code, section 907.6.6 requires fire alarm systems required by this chapter or by the International Building Code shall be monitored by an approved supervising station in accordance with NFPA 72. The 2015 International Fire Code section 903.4 requires all valves controlling the water supply for automatic sprinkler systems, pumps, tanks, water levels and temperatures, critical air pressures and waterflow switches on all sprinkler systems to be electrically supervised by a

listed fire alarm control unit. (monitored). Knox Box The 2015 International Fire Code, section 506.1 requires where access to or within a structure or an area is restricted because of secured openings or where immediate access is necessary for life-saving or fire-fighting purposes, the fire code official is authorized to require a key box to be installed in an approved location. The key box shall be of an approved type listed in accordance with UL 1037, and shall contain keys to gain necessary access as required by the fire code official. Please contact York County Department of Fire Safety at (803) 620-2270 for information regarding the required key box or order on-line at www.knoxbox.com Exterior Emergency Lights The 2015 International Fire Code, section 1008.3.2(5) requires exterior emergency lighting to be installed immediately adjacent to exit discharge doorways. Kitchen Hood / Suppression System The 2015 International Fire Code, section 609.2 requires a type I kitchen hood to be installed at or above all commercial cooking appliances and domestic cooking appliances used for commercial purposes that produce grease vapors. The 2015 International Fire Code, section 904.2.2 states: Each required commercial kitchen exhaust hood and duct system required by Section 609 to have a Type I hood shall be protected with an approved automatic fire-extinguishing system installed in accordance with this code. Ventilation System Interlock The 2015 International Mechanical Code, section 507.1.1 requires the exhaust fan serving a Type I hood to have automatic controls that will activate the fan when any appliance that requires such Type I Hood is turned on, or a means of interlock shall be provided that will prevent operation of such appliances when the exhaust fan is not turned on. Where one or more temperature or radiant energy sensors are used to activate a Type I hood exhaust fan, the fan shall activate not more than 15 minutes after the first appliance served by that hood has been turned on. Fire Extinguishers The 2015 International Fire Code, section 906.2 requires fire extinguishers to be selected, installed and maintained in accordance with this section and NFPA 10. Tactile Exit Signs The 2015 International Fire Code, section 1013.4 requires a sign stating EXIT in visual characters, raised characters and braille and complying with ICC A117.1 to be provided adjacent to each door to an area of refuge, an exterior area for assisted rescue, an exit stairway or ramp, an exit passageway and the exit discharge. Signs shall be placed on the wall, on the latch side of the door, 48 to 60 inches off of the floor.

Door Hardware The 2015 International Fire Code, section 1010.1.9.1 requires door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code to not require tight grasping, tight pinching or twisting of the wrist to operate. The 2015 International Fire Code, section 1010.1.9.5 requires the unlatching of any exit door leaf to not require more than one operation. Exit Doors The 2015 International Fire Code, section 1010.1.9 states: Except as specifically permitted by this section, egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. IFC section1010.1.9.1 states: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. Panic Hardware The 2015 International Fire Code, section 1010.1.10 requires each door serving a Group H occupancy and doors serving rooms or spaces with an occupant load of 50 or more in a Group A or E occupancy to not be provided with a latch or lock other than panic hardware or fire exit hardware. Flush Bolts The 2015 International Fire Code, section 1010.1.9.4 states: Manually operated flush bolts or surface bolts are not permitted. This includes the inactive leaf of a set of double doors. If the double door exit width is not required for exiting purposes, then the inside door hardware of the inactive leaf may be removed and the flush bolts can remain (effectively making the inactive leaf a window instead of an exit door). Spray Booth The 2015 International Fire Code, section 2404.7.1 requires spraying equipment to be interlocked with the ventilation of the spraying area such that spraying operations cannot be conducted unless the ventilation system is in operation. (Air valve interlock is required) Identification of Rooms The 2015 International Fire Code, section 509.1 requires fire protection equipment to be identified in an approved manner. Rooms containing controls for air-conditioning systems, sprinkler risers and valves, or other fire detection, suppression or control elements shall be identified for the use of the fire department. Approved signs required to identify fire protection equipment and equipment location, shall be constructed of durable materials, permanently installed and readily visible.

The 2015 International Fire Code, section 605.3.1 requires doors into electrical control panel rooms to be marked with a plainly visible and legible sign stating ELECTRICAL ROOM or similar approved wording. The 2015 International Fire Code, Section 5003.5 requires visible hazard identification signs as specified in NFPA 704 for the specific material contained to be placed on stationary containers and above-ground tanks and at entrances to locations where hazardous materials are stored, dispensed, used or handled in quantities requiring a permit and at specific entrances and locations designated by the fire code official. Pool chemical room shall be labeled with appropriate NFPA 704 signage. The 2015 International Building Code, section 703.7 requires where there is an accessible concealed floor, floor-ceiling or attic space, fire walls, fire barriers, fire partitions, smoke barriers and smoke partitions or any other wall required to have protected openings or penetrations to be effectively and permanently identified with signs or stenciling in the concealed space. Such identification shall: 1. Be located within 15 feet (4572 mm) of the end of each wall and at intervals not exceeding 30 feet (9144 mm) measured horizontally along the wall or partition. 2. Include lettering not less than 3 inches (76 mm) in height with a minimum 3/8-inch (9.5 mm) stroke in a contrasting color incorporating the suggested wording, FIRE AND/OR SMOKE BARRIER PROTECT ALL OPENINGS, or other wording. Fire Shutters The 2015 International Building Code, section 716.5.7 requires fire door and fire shutter assemblies to be installed in accordance with NFPA 80. (2013) NFPA 80, section 13.2.2. requires the sill for rated service counter fire doors to meet the requirements of section 4.8.2.4 which requires the sill to be of non-combustible materials. NFPA 80, section 13.3 requires, where counters are supplied separately from the balance of the shutter assemblies, they shall be labeled and installed in accordance with their listing. Daycare/Healthcare If the proposed facility is to be licensed or regulated by the state of South Carolina, plans and specifications shall be submitted to the regulatory authority for their review and approval. High Piled Combustible Storage The 2015 International Fire Code, chapter 2 defines "High Piled Combustible Storage" as: Storage of combustible materials in closely packed piles or combustible materials on pallets, in racks or on shelves where the top of storage is greater than 12 feet (3658 mm) in height. Where required by the fire code official, high-piled combustible storage also includes certain highhazard commodities, such as rubber tires, Group A plastics, flammable liquids, idle pallets and similar commodities, where the top of storage is greater than 6 feet (1829 mm) in height. No "High Piled Combustible Storage" is allowed unless meeting the requirement of the 2015 International Fire Code, Table 3206.2.

Sprinklers The South Carolina Fire Protection Sprinkler Systems Act, Section 40-10-260 (A) requires that sprinkler system shop drawings must be prepared for every fire protection sprinkler system to be installed in South Carolina. Shop drawings along with any specification sheets must be submitted to the local authority having jurisdiction (York County Dept. of Fire Safety) for review and approval. The South Carolina Fire Protection Sprinkler Systems Act, section 40-10-250, requires that a Fire Sprinkler System Specification Sheet, approved by the State Fire Marshal, be completed for every fire protection sprinkler system to be installed in South Carolina. This specification sheet must be submitted to the local authority having jurisdiction (York County Dept. of Fire Safety) for review and approval. The South Carolina Fire Protection Sprinkler Act, section 40-10-260 (D), requires that a Certificate of Compliance certifying that the fire protection sprinkler system was designed and installed in accordance with the Fire Sprinkler Specification Sheet must be delivered to the local authority having jurisdiction (York County Dept. of Fire Safety). South Carolina State Law 40-10-250 section C requires, when applying for building permits or other required permits, the Fire Sprinkler System Specification Sheet completed in accordance with subsections (A) and (B) must be made part of the bid documents and must be submitted to the authority having jurisdiction (York County Dept. of Fire Safety), along with the architectural or engineering, or both, drawings and specifications. The completed Fire Sprinkler System Specification Sheet must accompany the shop drawings when they are submitted for review. The Fire Sprinkler Specification Sheet and drawings must be submitted prior to permits being issued. Sprinkler Earthquake Protection NFPA 13 (2010), section 9.3.1 requires sprinkler systems to be protected against earthquake damage. Please provide details on earthquake protection. Re-submittal Information To expedite the review of the re-submitted documents, in addition to the revised drawings, please submit a letter outlining the changes made to each of the items listed above. If further information is needed regarding this portion of the plan review, please call The York County Department of Fire Safety at 803-620-2270.