TrueAlert Multi-Candela Notification Appliances

Similar documents
TrueAlert Multi-Candela Notification Appliances

TrueAlert ES Addressable Notification Appliances

TrueAlert Addressable Notification Appliances

TrueAlert Notification Appliances

TrueAlert Addressable Notification Appliances

LifeAlarm Fire Alarm Controls

TrueAlert Non-Addressable, Multi-Candela Notification Appliances Installation Instructions

TrueAlert Addressable Notification Appliances

Releasing System Peripherals

TrueAlert Addressable Notification

Multi-Application Peripherals

System Accessories, LCD Annunciators

LifeAlarm Fire Alarm Control Panels

s Notification Appliances

Fire Control Panels. Automatic Extinguishing, Deluge and Preaction Sprinkler System Releasing Control

08 Series Notification Appliances AS / AH & AS Audible Strobe Appliances and AH Audibles Application: Indoor / Outdoor

SELECT-A-HORN/STROBE SERIES

TrueAlarm Analog Sensing

TrueAlarm Analog Sensing

TrueAlarm Smoke Detectors

Multi-Point Peripherals

TrueAlarm ES Analog Sensing

SpectrAlert Advance. Field-Selectable Mass Notification Devices. Description. An ISO Company SIGNALING. MEA Approved E

Life safety notification

Wheelock RSS & RSSP Series

CSH24CH. Colored Light Strobe/Horn Series High Candela. Description. Features. Ceiling/Wall Mount Patent Pending. Ordering Information

Genesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet

11:00 to 12:00 Secrets to achieving code-compliant strobe installations. Ralph Coco, Potter Canada Paul Jewett, Mircom Group of Companies

Rev. B. TrueAlert Addressable Controller Application Manual

Genesis LED G1 Series

TrueAlert Addressable Notification Appliances

XP6-C. Six Circuit Supervised Control Module and SYNC-1 Accessory Card

L-Series, Emergency Communication Devices

Specification/ Data Sheet

L-Series, Indoor Strobes and Horn Strobes

'08 Series Notification A liances

MEA. SpectrAlert Series Horns, Strobes, and Horn/Strobes GENERAL

L-Series, Indoor Strobes and Horn Strobes

Speakers and Speaker Strobes

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for Panel and Remote Mounting. Features. Operation.

/5121/5122 TrueAlert Power Supply Installation Instructions

Release Control Fire Alarm Systems

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

Field Configurable Horns and Strobes

1 Watt Supervised Self-Amplified Strobe Speakers Round Flush Grille with 75cd Strobe

Field Configurable Horns and Strobes

Selectable Output Chimes and Chime/Strobes

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

Signature Series Auto-Sync Output Module (CC1S)

AL800ULADA. NAC Power Extender. Installation Guide

Use this product according to this instruction manual. Please keep this instruction manual for future reference.

Dimensions of the Optional Mounting Box (BB-400R/W)

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION FIRE ALARM SYSTEM

SIGA-CC1 Single Input Signal Module Installation Sheet

4007ES Fire Control Panels

July 14, 1999 DF C-100.

SECTION FIRE ALARM SYSTEMS

Addressable Fire Alarm Control Panel

SAFEPATH SAFEPATH. Emergency communications system

Fire Alarm System Accessories

Potter Wall Mount Select-A-Strobe

SP40S-D. Kingfisher Company, inc. Features: Description:

Print Specification. Publication. Instructions. Specific requirements. General requirements

SAFEPATH Mass Notification System (SPMNS)

PROPERTY COMMITTEE AGENDA. Deviation from the order shown may occur

Autonomous control unit

June 10, 2002 DF C S2424

Smoke Detector Activation of any smoke detector shall start the alarm verification mode.

AL602ULADA AL802ULADA AL1002ULADA

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

*15cd models are Listed at 15cd and meet 75cd on axis

Fire Control Panels. Automatic Extinguishing, Deluge and Preaction Sprinkler System Releasing Control

Performance Based Design: Fire Alarm Visual Notification Appliances - Mathematical Guide. Ernesto Vega Jánica, EE, MSc, MEng

2. HVAC and smoke control systems; fire, smoke, and combination fire/smoke dampers. 5. Central control and monitoring system.

Z-20 Fire Control Panels

Fire Control Panels. Addressable Fire Detection and Control Emergency Voice/Alarm Communications Equipment

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

ELECTRONIC SOUNDER STROBE Model : AVD-C407

AL1042ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

DIVISION 26 ELECTRICAL SECTION FIRE ALARM SYSTEM

Multi-Point Peripherals

4007ES and 4007ES Hybrid Fire Alarm Systems Installation Manual

good things in small packages

Fire Alarm System Fundamentals

DETCON MODEL AV2-C1D2C Hazardous Duty Class I. Div 2, Continuous Tone Alarm Station

advancedsolutions Advanced Design. We have engineered all SpectrAlert products to meet or exceed code today and tomorrow. We ve worked to standardize

AND ARCHITECT SPECIFICATIONS

4007ES Fire Control Panels

AL1002ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

TrueAlarm Analog Sensing

SLVMC - Oncology & Infusion Remodel & Add 17D /4/2017

ECC-50/100C. Emergency Command Center

AL600ULADA. NAC Power Extender. Installation Guide

SECTION FIRE ALARM STANDARDS REVISED CONSTRUCTION STANDARD

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for 4120 Network. UL, ULC, CSFM Listed; FM Approved* Features

M O D E L S F I R E G A R D M C V ADVANCE FIRE CONTROL RELEASE DEVICE

SAFEPATH DoD facility communications system & expansion options

Analog fire panels FPA-1000 Family

Transcription:

UL, ULC Approved* TrueAlert Multi-Candela Notification Appliances Non-Addressable Visible Only Amber Lens Strobes for Emergency Communications Features Visible only (V/O) 24 VDC wall mount notification appliances with high output xenon strobe: Amber lens with "ALERT" lettering produces a signal unique from clear lens fire alarm evacuation strobes for use with Emergency Communications Systems Intensity is selectable as 15, 30, 75, or 110 candela with visible selection jumper secured behind strobe housing UL listed to Standard 1638 (due to non-white lens); verified by UL testing to provide light dispersion patterns of UL Standard 1971 at rated candela (no derating necessary for amber lens) ULC listed to Standard S526 Polarized input allows connection to compatible reverse polarity, supervised notification appliance circuit (NAC) Regulated circuit design ensures consistent flash output and provides controlled inrush current Rugged, high impact, flame retardant thermoplastic housings are available in red or white with amber lens Strobes provide synchronized flash for use with: 4100ES Series fire alarm control panels with NACs selected to provide strobe synchronization or SmartSync two-wire horn/strobe control 4009 IDNet NAC Extenders Separate strobe synchronization modules that are available for Class B or Class A operation Separate SmartSync Control Modules (SCMs) that provide Class B or Class A output from conventional NAC inputs Note: Connect amber strobes to NACs dedicated for Emergency Communications operation, not for fire alarm notification Strobe housings provides flexible, easy, and convenient semi-flush or surface mounting: Rear of housing does not extend into box Strobes easily mount to single gang, double gang, or 4-inch square outlet box Wiring terminals are accessible from the front of the housing providing easy access for installation, inspection, and testing Optional adapters and wire guard: Strobe adapters are available to cover surface mounted electrical boxes and to adapt to 2975-9145 boxes UL listed red wire guard Fig 1: Amber Lens Wall Mount Strobes Description TrueAlert amber lens multi-candela strobes provide non-fire alarm alert notification for use with Emergency Communications systems where additional response information is provided by audio or textual appliances. Strobe housings are a one-piece assembly (including lens) that mounts to a single or double gang, or 4" square standard electrical box. The cover can be quickly removed (a tool is required) and the enclosure design is impact and vandal resistant. Multi-Candela Output During installation, a selection plug at the back of the housing determines the desired strobe intensity. An attached flag with black letters on a highly visible yellow background allows the selected intensity to be seen at the side of the strobe lens. Strobe Application Reference Amber strobes used as part of an Emergency Communications system are located to provide the same area coverage as required of clear lens fire alarm strobes. Specific Emergency Communications requirements are discussed in detail in document UFC 4-021-01 (USA Department of Defense, United Facilities Criteria) and in NFPA 72, Chapter 24 (2010 and 2013 editions). Proper strobe coverage criteria is further described in the National Fire Alarm and Signaling Code (NFPA 72), ANSI A117.1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA). * Additional listings may be applicable; contact your local product supplier for the latest status. AC4906-0008 Rev. 4 1/2013

Synchronized Strobes Multiple Strobes Non-Addressable Visible Only Amber Lens Strobes for Emergency Communications When multiple strobes and their reflections can be seen from one location, synchronized flashes reduce the probability of photo-sensitive reactions as well as the annoyance and possible distraction of random flashing. These multi-candela strobes are synchronized over a two-wire circuit when connected to compatible NACs, to compatible Synchronized Flash Modules, or to SmartSync Control Modules. SmartSync Two-Wire Control Reference Fire Alarm Operation SmartSync two-wire control provides separate horn and strobe control over the same wiring. This allows audible notification appliances to be capable of being silenced before the alarm condition is reset (on-until-silenced) while the visible notification appliances are kept activated until the alarm condition is reset (on-until-reset). Alert Operation When non-addressable amber strobes are used to provide alert indications, audible information is provided by a voice/audio system or other unique, non-fire alarm signaling. Refer to the Additional Reference list to the right for associated products. Some applications requiring multiple NAC synchronization may require amber strobe control from synchronized A4905-9938 SmartSync Control Modules. Additional Reference Table 1: Multi-Candela Clear Lens Strobes V/O (strobe) A/V (horn/strobe) S/V (speaker/strobe) AC4906-0001 AC4906-0002 AC4906-0003 Table 2: Audible Notification Horn Speakers AC4901-0010 AC4902-0003 Synch and SmartSync Control Modules Table 3: Control Modules and Panels AC4905-0003 4009 IDNet NAC Extender AC4009-0002 4010 Fire Alarm Control Panels AC4010-0001 4100ES Fire Alarm Panels 4100ES Fire Alarm Audio Equipment 4003 Series Emergency Voice/Alarm Communications Equipment Panel (compatible with 4010 control panels) AC4100-0031 AC4100-0034 AC4003-0001 Table 4: Installation Reference Installation Instructions 579-848AC Page 2 AC4906-0008 Rev. 4 1/2013

Non-Addressable Visible Only Amber Lens Strobes for Emergency Communications Selection Table 5: Multi-Candela Visible Notification Appliances (Strobes) SKU Housing Color "ALERT" Lettering Description A4906-9107 White Red A4906-9108 Red White Multi-candela strobe with amber lens; intensity selectable as: 15, 30, 75, or 110 candela; synchronized flash rate; SmartSync two-wire control compatible Table 6: Mounting Adapters SKU Description Dimensions A4905-9937 Red A4905-9940 White A4905-9931 Surface Mount Adapter Skirt; use to cover 1-1/2" (38 mm) deep surface mounted boxes Red Adapter Plate for mounting to 2975-9145 box (typically for retrofit, may be mounted vertical or horizontal) 2975-9145 Red Mounting Box, requires Adapter Plate A4905-9931 5-3/8" H x 5-1/4" W x 1-5/8" D (136 mm x 133 mm x 41 mm) Total depth with strobe = 4-3/8" (111 mm) 8-5/16" x 5-3/4" x 0.060" Thick (211 mm x 146 mm x 1.5 mm) 7-7/8" x 5-1/8" x 2-3/4" D (200 mm x 130 mm x 70 mm) Table 7: Synchronization Modules (refer to data sheet AC4905-0003 for additional information) SKU Description Dimensions A4905-9914 Class B A4905-9922 Class A A4905-9938 Synchronized Flash Module; epoxy encapsulated with in/out 18 AWG (0.82 mm2) wire leads, rated for 2 A NAC, requires 10 ma for power SmartSync Control Module with Class B or Class A output; mounts in 4" (102 mm) square box 1-3/8" x 2-7/16" x 13/16" (35 mm x 62 mm x 20 mm) 4" x 4-1/8" x 1-1/4" D (102 mm x 105 mm x 32 mm) Table 8: Wire Guard SKU Description Dimensions 4905-9961* Red wire guard with mounting plate, compatible with semi-flush or surface mounted boxes Note: * UL listed by Space Age Electronics Inc. 6-1/16" H x 6-1/16" W x 3-1/8" D (154 mm x 154 mm x 79 mm) Page 3 AC4906-0008 Rev. 4 1/2013

Non-Addressable Visible Only Amber Lens Strobes for Emergency Communications Strobe Specifications Specification Voltage Range Flash Rate Synchronized NAC Loading Table 9: Strobe Specifications Rating Regulated 24 VDC; see Note 1 below 1 Hz Up to 35 synchronized strobes maximum per NAC Temperature Range 32 to 122 F (0 to 50 C) Humidity Range 10% to 93%, non-condensing at 100 F (38 C) Connections Housing Dimensions (with lens) Terminal blocks for 18 AWG to 12 AWG (0.82 mm 2 to 3.31 mm 2 ); two wires per terminal for in/out wiring 5-1/8" H x 5" W x 2-3/4" D (130 mm x 127 mm x 70 mm) Maximum RMS Current Rating per Strobe Setting (see 15 cd 30 cd 75 cd 110 cd Note 2 below) 60 ma 94 ma 186 ma 252 ma Reference RMS Currents at other voltages Note: 18 VDC 53 ma 84 ma 165 ma 224 ma 24 VDC 40 ma 63 ma 124 ma 168 ma 1. "Regulated 24 VDC" refers to the voltage range of 16 to 33 VDC per UL Standard 1638, Visual Signaling Appliances Private-Mode Emergency and General Utility Signaling. This voltage range is the absolute operating range. Operation outside of this range may cause permanent damage to the strobe. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. 2. The maximum RMS current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) Installation Reference, Surface or Semi-Flush Mounting Fig 2: Installation Reference, Surface or Semi-Flush Mounting Fig 3: Wall mount reference Page 4 AC4906-0008 Rev. 4 1/2013

Non-Addressable Visible Only Amber Lens Strobes for Emergency Communications Installation Reference; Adapter Plate, Guard, and Adapter Skirt Fig 4: Installation Reference; Adapter Plate, Guard, and Adapter Skirt Note: Figure 4 shows: 1. 2975-9145 back box 2. Surface mount reference shows optional red (A4905-9937) and white (A4905-9940) surface mount adapter skirt 3. A4905-9931 adapter plate 4. 4905-9961 optional wire gaurd Page 5 AC4906-0008 Rev. 4 1/2013

2017 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision and are subject to change without notice. Additional listings may be applicable, contact your local Autocall product supplier for the latest status. Listings and approvals under Tyco Fire & Security GmbH, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). AC4906-0008 Rev. 4 1/2013