FOR SERVICE TECHNICIAN S USE ONLY

Similar documents
FOR SERVICE TECHNICIAN S USE ONLY

FOR SERVICE TECHNICIAN S USE ONLY

FOR SERVICE TECHNICIAN S USE ONLY

Bottom Mount Refrigerator---Technical Information

CAUTION. No-Load Performance, Controls in Normal Position

AFI2538AE* AFI 2538AE*0, MFI2568AE* MFI2568AE*0 CAUTION

Due to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator.

JBL2088HES JBL2088HES0, JBR2088HES JBR2088HES0, JFC2089HEP JFC2089HEP0, JFC2089HES JFC2089HES0, JFC2089HPF JFC2089HPF0, JFC2089HPY JFC2089HPY0

CAUTION. No-Load Performance, Controls in Normal Position. Percent Run Time ±10%

SERVICE MANUAL MATRIX 18.2 CU FT TOP MOUNT REFRIGERATOR

Fast Track Troubleshooting

Model Number Nomemclature... 1 Specifications... 3 Refrigeration System... 4 Freezer and Refrigerator Air Circulation... 5 Display Designs...

Fast Track Troubleshooting

WRF560SEYW01 CABINET

Fast Track Troubleshooting

CAUTION. All safety information must be followed as provided in Service Manual RS ! WARNING

Bottom Mount Refrigerator Technical Information

Due to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator.

Image Key Part Number Description Substitution Qty.

CABINET PARTS For Model: KSF26C6XYY00 (Monochromatic Stainless)

4. ALIGNMENT AND ADJUSTMENTS

Fast Track Troubleshooting

Fast Track Troubleshooting

CABINET PARTS For Models: KSC24C8EYW00, KSC24C8EYB00, KSC24C8EYP00, KSC24C8EYY00 (White) (Black) (Stainless) (Monochromatic Stainless)

REFRIGERATOR MODELS: KFIS29BBWH02 (White) KFIS29BBBL02 (Black) KFIS29BBMS02 (Monochromatic Stainless) 08/02/2013 Part No. W Rev.

CABINET PARTS For Models: GSS30C6EYY01 (Monochromatic Stainless)

REPAIR PARTS LIST REFRIGERATOR. Model No.(s) (White) (Stainless Steel) (Black)

CAUTION. No-Load Performance, Controls in Normal Position. Percent Run Time ±10% Temperature Relationship Test Chart.

REFRIGERATOR MODELS: KFIS27CXMS5 (Monochromatic Stainless) 09/18/2013 Part No. W Rev. D

2008 DOUBLE DRAWER UNDER COUNTER REFRIGERATOR / FREEZER PRODUCTS

Ice Maker (Fresh Food Compartment)

REFRIGERATOR MODELS: WRF560SFYW02 (White) WRF560SFYH02 (White Ice) WRF560SFYB02 (Black) WRF560SFYM02 (Monochromatic Stainless)

CABINET PARTS For Models: GSS26C5XXW00, GSS26C5XXB00, GSS26C5XXA00, GSS26C5XXY00 (White) (Black) (Monochromatic (Monochromatic Satina) Stainless)

REFRIGERATOR MODELS: KFIV29PCMS01 (Monochromatic Stainless) 04/02/2014 Part No. W Rev. B

Fast Track Troubleshooting

4. Alignment and Adjustments

FRENCH DOOR BOTTOM MOUNT REFRIGERATOR MODELS: WRF560SEHW00 (White) WRF560SEHB00 (Black) WRF560SEHV00 (Black Stainless) WRF560SEHZ00 (Stainless)

FRENCH DOOR BOTTOM MOUNT REFRIGERATOR MODELS: KFIS29BBWH03 (White) KFIS29BBBL03 (Black) KFIS29BBMS03 (Monochromatic Stainless Steel)

Side-by-side combined refrigerator-freezer

CABINET PARTS For Models: JCD2595WES02, JCD2595WEK02, JCD2595WEP02 (Stainless)(Stainless On Stainless)(Stainless Pro) REFRIGERATOR

CABINET PARTS For Models: KFIL27CXMS5 (Monochromatic Stainless)

WD6078A00 LINER REFRIGERADOR

REFRIGERATOR MODELS: WRF560SMYW02 (White) WRF560SMYB02 (Black) WRF560SMYM02 (Monochromatic Stainless)

WD6971Y00 LINER REFRIGRADOR

CABINET PARTS For Models: GSC25C6EYY01 (Monochromatic Stainless)

3. OPERATING INSTRUCTIONS & INSTALLATION

REFRIGERATOR MODELS: KFFS20EYWH01 (White) KFFS20EYBL01 (Black) KFFS20EYMS01 (Monochromatic Stainless) 11/05/2013 Part No. W Rev.

REFRIGERATOR MODELS: 07/24/ Whirlpool Corporation Part No. W Rev. A

Part No. W Rev. B Litho in U.S.A. (wam) (eeb) REFRIGERATOR

REFRIGERATOR MODELS: WRF560SEYW04 (White) WRF560SEYB04 (Black) WRF560SEYM04 (Monochromatic Stainless)

SERVICE MANUAL REFRIGERATION

CABINET PARTS For Model: KSSC42QTS02 (Stainless Steel)

2010 Whirlpool 26 SXS Refrigerators

CABINET PARTS For Models: WSF26C2EXW01, WSF26C2EXB01, WSF26C2EXY01, WSF26C2EXF01 (White) (Black) (Monochromatic (Monochromatic

Image Key Part Number Description Substitution Qty.

FRENCH DOOR BOTTOM MOUNT REFRIGERATOR MODELS: WRF560SEYW05 (White) WRF560SEYB05 (Black) WRF560SEYM05 (Stainless Steel)

CABINET PARTS For Model: JS48NXFXDW03 (Base Model)

REFRIGERATOR 30 INCH FRENCH DOOR BOTTOM MOUNT MODELS: WRF560SMYW00 (White) WRF560SMYB00 (Black) WRF560SMYM00 (Monochromatic Stainless)

Service Information. WNes 2956 appliance documentation. Service Information no. 27/2004 LHG/TKD-Fe/June SI

CABINET PARTS For Models: WRT771REYW00, WRT771REYB00, WRT771REYM00 (White) (Black) (Mono Stainless)

Service & Parts Manual

CABINET PARTS For Models: KSSS42QTW03, KSSS42QTB03, KSSS42QTX03 (White) (Black) (Etched Aluminum)

6 10 Litho In U.S.A. (mat) (psw) Part No. W Rev. B REFRIGERATOR

REFRIGERATOR 25 Cubic Foot 4 Door Bottom Mount MODELS: WRX735SDBM00 (Stainless Steel) 02/21/ Whirlpool Corporation Part No. W Rev.

CABINET PARTS. For Models: KBFS20ETWH01, KBFS20ETBL01, KBFS20ETSS01 (White) (Black) (Stainless Steel) 5 08 Litho In U.S.A. (CJJ)

CABINET PARTS For Model: KBLC36FTS06 (Stainless Steel)

FOUR DOOR FRENCH DOOR REFRIGERATOR MODELS: WRX988SIBH03 (White Ice) WRX988SIBE03 (Black Ice) WRX988SIBM03 (Monochromatic Stainless)

All Freestanding SxS Refrigerators

REFRIGERATOR Models:

TFFR01 MANUAL PORTABAL 12/24 VOLTS DC REFRIGERATOR / FREEZER.

CABINET PARTS For Model: JS42CXFXDB00 (Etched Aluminum)

SERVICE MANUAL REFRIGERATION

CABINET PARTS For Model: KSSC42QVS03 (Stainless Steel)

CABINET PARTS For Model: KSSC48QVS02 (Stainless Steel)

TECHNICAL SERVICE GUIDE

Fast Track Troubleshooting

CABINET PARTS For Model: KBFC42FTS03 (Stainless Steel)

K00364 Electronic Bin Thermostat

BOTTOM MOUNT FRENCH DOOR REFRIGERATOR MODELS: WRF757SDEH01 (White Ice) WRF757SDEE01 (Black Ice) WRF757SDEM01 (Monochromatic Stainless Steel)

CABINET PARTS Printed In U.S.A. (mat) Part No. W Rev. B

REFRIGERATOR MODELS: JFX2597AEP2 (Stainless Steel) 05/02/ Jenn-Air Part No. W Rev. B

SIDE BY SIDE REFRIGERATOR MODELS: WRS571CIHW01 (White) WRS571CIHB01 (Black) WRS571CIHV01 (Black Stainless) WRS571CIHZ01 (Stainless Steel)

Fast Track Troubleshooting

SIDE BY SIDE REFRIGERATOR MODELS: WRS571CIHW00 (White) WRS571CIHB00 (Black) WRS571CIHV00 (Black Stainless) WRS571CIHZ00 (Stainless)

CABINET PARTS For Model: KSSO36FMX01 (Etched Aluminum)

Fast Track Troubleshooting

REFRIGERATOR Models:

FOUR DOOR BOTTOM MOUNT REFRIGERATOR MODELS: WRX735SDBH00 (White Ice) WRX735SDBE00 (Black Ice) WRX735SDBM00 (Monochromatic Stainless Steel)

ARS2304A PARS2304AB0 ARS2604A PARS2604AB0 ARS2304A PARS2304AC0 ARS2604A PARS2604AC0 ARS2304A PARS2304AW0 ARS2604A PARS2604AW0 !

CAREL IR33+ CONTROLLER

REFRIGERATOR Models:

CABINET PARTS For Model: GX5FHTXVY05 (Monochromatic Stainless)

VCBF136RSS3 : CABINET [1/9]

26 CUBIC FOOT FRENCH DOOR BOTTOM MOUNT REFRIGERATOR MODELS: MFI2670XEM7 (Monochromatic Stainless Steel)

10. Circuit Descriptions

CABINET PARTS. For Models: MSD2269KEW02, MSD2269KEB02, MSD2269KEY02, MSD2269KEA02 (White) (Black) (Stainless Steel)(Monochromatic Satina)

CABINET PARTS For Models: KFCS22EVMS7 (Monochromatic Stainless)

40KMC KMQ

quick start guide Product features RFG298HD* RFG297HD* RFG296HD* RFG29PHD* RFG29THD* English Surround Multi Flow 16" Pizza Corner Twin Cooling System

CABINET PARTS For Model: EF42DBSS02 (Stainless Steel)

Transcription:

W10832390C FOR SERVICE TECHNICIAN S USE ONLY NOTE: This sheet contains important Technical Service Data. Tech Sheet Do Not Discard DANGER Electrical Shock Hazard Only authorized technicians should perform diagnostic voltage measurements. After performing voltage measurements, disconnect power before servicing. Failure to follow these instructions can result in death or electrical shock. WARNING Electrical Shock Hazard Disconnect power before servicing. Replace all parts and panels before operating. Failure to do so can result in death or electrical shock. Voltage Measurement Safety Information When performing live voltage measurements, you must do the following: Verify the controls are in the off position so that the appliance does not start when energized. Allow enough space to perform the voltage measurements without obstructions. Keep other people a safe distance away from the appliance to prevent potential injury. Always use the proper testing equipment. After voltage measurements, always disconnect power before servicing. Component Specifications Component Cooling Compressor WMD7H Electric damper control Condenser fan motor Refrigerator fan motor Freezer fan motor Icebox fan motor Freezer heater Specifications all parts 115VAC/60HZ unless noted Capacity...921 BTU/H (270 W) Watt... 144 watts Current lock rotor...1 amp Current full load...1.1 amp Resistance run windings... 9.6 ohms Maximum closing time... 16 seconds Temperature rating...-11ºf/110ºf RPM... 3 Rotation...Clockwise RPM... 1330 RPM Watt... 2.3 watts Volt... 115 VAC Watt...435 ±5% watts 1

To Enter Service Diagnostics Mode: Service mode requirement Enter Service Key Combination Enter Key for Navigation Increment Key for Navigation Decrement Key for Navigation Back Key for Navigation Degree C LED Indicator Degree F LED Indicator Control Board Troubleshooting Keep both and buttons pressed for 3 seconds. Countdown will display and a chime will play upon entry into Service mode. Button on Main UI and temperature buttons pressed for 3 seconds Drawer button + button on the upper 7 segment display - button on the upper 7 segment display Max Cool button C indicator F indicator To Exit Service diagnostics, use Max Cool Key to back out of functional test. Press and hold - and - temperature buttons simultaneously for 3 seconds. NOTE: If a test or mode runs over 99 on the display, the User Interface will flash digit 1 for one second, and then display digit 2. The number will display. i.e. 100 will display 1 first for one second, then display 00. 101 will display 1 first for one second, and then display 01, etc. Service Test - 00 Exit Service Mode: This step is an alternative method to exit service mode and return to Normal Operation. Service Test - 01 RC Thermistor Read RC compartment Temperature. SH indicates shorted thermistor, OP indicated open thermistor. Service Test - 02 FC Thermistor Read FC compartment Temperature. SH indicates shorted thermistor, OP indicates open thermistor. Service Test - 03 RC Evaporator Thermistor Read Refrigerator Evaporator Temperature. SH indicates shorted Service Test - 04 FC Evaporator Thermistor Read Freezer Evaporator Temperature. SH indicates shorted Service Test - 05 Pantry Thermistor Read Pantry compartment Temperature. SH indicates shorted Accessing Service Mode 2 Service Test - 14 Door Ice Box Thermistor Read RC compartment Temperature. SH indicates shorted thermistor, OP indicated open thermistor. Service Test - 16 Door Ice Maker Tray Thermistor Read Icemaker Tray C Temperature. SH indicates shorted thermistor, OP indicates open thermistor. Service Test - 23 RC Maximum Temperature; Service Test - 24 FC Maximum Temperature; Service Test - 25 Pantry Maximum Temperature; Service Test - 26 Ice Box Maximum Temperature Maximum temperature reached during the last 6 hours of operation. Temperature is saved every hour, keeping the last 6 hours for analysis. The maximum is displayed on the UI screen from the last six saved values. Service Test - 28 RC Average Temperature; Service Test - 29 FC Average Temperature; Service Test - 30 Pantry Average Temperature; Service Test - 31 Ice Box Average Temperature Average temperature during the last 6 hours of operation. Average is calculated using a running average filter. Service Test - 33 RC Minimum Temperature; Service Test - 34 FC Minimum Temperature; Service Test - 35 Pantry Minimum Temperature; Service Test - 36 Ice Box Minimum Temperature Minimum temperature reached during the last 6 hours of operation. Temperature is saved every hour, keeping the last 6 hours for analysis. The minimum is displayed on the UI screen from the last 6 saved values. Service Test - 38 Compressor Speed Change without Ramp Control the compressor speed. When entering Service Test, the compressor goes off if it was previously on. Change the compressor duty cycle between 0 and the maximum compressor speed by pressing + to increment and - to decrease the speed. For Linear Compressors there is a compressor protection against shutting the compressor off for 2½ minutes after changing to the ON state. Therefore the compressor will run for 2½ minutes after changing the speed. Service Test - 39 Compressor Speed Change with Ramp Control the Compressor Speed. When entering Service Test the compressor goes off if it was previously on. Select the power from 0 to 160W by pressing - or +. After pressing Enter the compressor will ramp up to the selected power. After changing the power button to 0W, the compressor will shut off after 2.5 minutes. Service Test - 40 Compressor and Compartment Freezing Cooling Test When entering the service test, compressor runs at max power. There will be a delay of 3 seconds before start of routine 01. 01 Dual Evap Valve will be open for both compartments for 4 mins. 02 Will close both RC and FC Dual Evap Valve (1 min.) 03 - Compressor turns on (1 min) 04 Compressor keeps on, Dual Evap Valve will be in RC position and RC Fan ON. (2 min.) 05 Compressor keeps on, Dual Evap Valve will be in FC position and FC Fan ON. (Run until technician presses BACK or Increment/ Decrement key.) Service Test - 42 Main Pantry Air Baffle State When entering Service Test, the damper continuously turns, showing the state in the numeric display. Possible position readings: 00 Air baffle in open position, 02 Air baffle in closed position. Service Test - 44 RC Compartment Lighting When entering Service Test, the Refrigerator Compartment Lights turn on. The display When leaving Service Test the Refrigerator Compartment lights turn off. Service Test - 45 FC Compartment Lighting When entering Service Test, the Freezer Compartment Lights turn on. The display When leaving Service Test, the Freezer Compartment Lights turn off. Service Test - 48 Pantry and Air Filter Lighting When entering Service Test, the Pantry, Air Filter, and Crisper Lights turn on. The display When leaving Service Test, the Pantry, Air Filter, and Crisper Lights turn off.

Service Test - 56 FC Fan Test When entering Service Test, the Freezer Fan turns on. The display When leaving Service Test, the Freezer Fan turns off. Service Test - 57 RC Fan Test When entering Service Test, the Refrigerator Fan turns on. The display When leaving Service Test, the Refrigerator Fan turns off. Service Test - 58 Condenser Fan Test When entering Service Test, the Condenser Fan turns on. The display When leaving Service Test, the Condenser Fan turns off. Service Test - 59 Ice Box Fan Test When entering Service Test, the Ice Box Fan turns on. The display When leaving Service Test, the Ice Box Fan turns off. Service Test - 63 Vertical Mullion Heater Test When entering Service Test, the Vertical Mullion Heater turns on. The display When leaving Service Test, the Vertical Mullion Heater turns off. Service Test - 65 Ice Box Duct Heater Test When entering Service Test, the Ice Box Duct Heater turns on. The display When leaving Service Test, the Ice Box Duct Heater turns off. Service Test - 66 Door Ice Maker Fill Tube Heater Test When entering Service Test, the Door Ice Maker Fill Tube Heater turns on. The display When leaving Service Test, the Door Ice Maker Fill Tube Heater turns off. Service Test - 70 Dispenser Heater Test When entering Service Test, the Dispenser Heater turns on. The display When leaving Service Test, the Dispenser Heater turns off. Service Test - 73 Right RC Door Switch State Service Test - 74 Left RC Door Switch State Service Test - 75 FC Door Switch State Service Test - 79 Ice Bin Switch State 00 identifies bin missing, 01 identifies bin present. Service Test - 85 Vertical Mullion Heater Activation Mode 00 indicates mullion heater controlled by measured humidity. 01 indicates mullion heater always on. Service Test - 87 Dispenser Heater Activation Mode 00 indicates dispenser heater controlled by measured humidity. 01 indicates dispenser heater always ON. Service Test - 88 Ice Box Air Duct Heater Activation Mode 00 indicates dispenser heater controlled by cooling performance. 01 indicates dispenser heater always ON. Service Test - 89 Run FC Defrost Heater When entering this Service Test, defrost heater turns on and stays on for 5 minutes or until the thermistor goes above 60 F. ON will be displayed while the operation is executed. Service Test - 91 Run a Forced Defrost Activates the forced defrost. When ON is selected and exiting Service mode, defrost will be executed. When OFF is selected and exiting Service mode, defrost will NOT be executed. To advance between control mode ON or OFF Use + or - key. Once desired setting is selected, push Drawer key to activate then Max Cool to Service Test - 92 Turn All UI LEDs ON When entering Service Test all indicators and buttons will light up in the two UIs. The icons turn automatically off after 30 seconds. Service Test - 93 UI Button and Pad/Paddle Test When inside Service Test, the numeric display shows 00 for no key press and 01 for key or pad pressing. Service Test - 96 Water Valve General Test When entering Service Test, the Water Dispenser Valve turns on for 7 seconds. Service Test - 97 Door Ice Maker Valve General Test When entering Service Test, the Door Ice Maker Water Valve turns on for 7 seconds. Service Test - 100 Display Water Filter Gallons Remaining Displays the remaining gallons of water left on the water filter. Service Test - 101 Display Water Filter Days Remaining Displays the remaining days left on the water filter. Service Test - 102 Display Days since Last Water Filter Reset Displays the total amount of days since the last water filter reset. Service Test - 103 Display Number of Water Filter Resets Displays the total amount of water filter resets that have occurred over the life of the product. Service Test - 104 Read Humidity Measurement Displays measured humidity as a percentage. Service Test - 105 Air Filter Usage Displays the total amount of days since the last air filter reset. Service Test - 106 Wi-Fi Link Connection Self Test While the test is in progress, the display will show: 00 Link Test in Progress. Following the completion of the Link Test, the display will transition to the following code designation: 01 Not able to link with AP or WISE. 02 Not able to link with WISE. 03 Connected to AP and WISE. Service Test - 108 WI-FI Antenna 1 Signal Strength Display the measured value as a percentage of possible range. The possible range to the technician is 0 to 100%. Service Test - 110 Display Current Smart Grid Mode Display 0 for Smart Grid mode not active, 1 for delay ice making Smart Grid mode active, 2 for delay ice making and cooling Smart Grid mode active. Service Test - 111 Smart Grid Mode 1 Counter Displays the number of times the unit has entered Smart Grid mode 1. Allowable range is from 0 to 999 instances. Service Test - 112 Smart Grid Mode 2 Counter Displays the number of times the unit has entered Smart Grid mode 2. Allowable range is from 0 to 999 instances. Service Test - 115 Control Ice Door Motor Using Ice Pads The display will follow the door position during this test using the following designation: 01 Closed 02 Opening 03 Open 04 Closing 3

Service Test - 120 Door Ice Maker self diagnostics The display shall show the following transitions as they occur. 00 Stopped 01 Moving Counterclockwise to Ice Break Position 02 Moving Clockwise to End of Harvest Location If Ice Bin Is Full Jump To Step 04 If Timeout Occurs (60 seconds) Execute Step 04 03 Reached End of Harvest Location 04 Moving Counterclockwise Back To Homing Location If Timeout Occurs (60 seconds) End Test The display shall show to the error codes following the execution of the test. PA All Steps Successfully Passed bf Ice Bin Is Full E1 Cannot Find Ice Break Position E2 Cannot Find End of Harvest Location E3 Cannot Find Home E4 Multiple Failures Service Test - 126 Change Defrost Type Displays the current Defrost mode. (01 Default) Engineer will then choose between the 2 available modes. Pressing the ENTER key will save the selection. The display will then return to Service Test Screen where the selected duty cycle will be displayed. Available defrost modes: 01 Global Defrost Routine ON 02 Basic Mode ON (8 hour timer) Service Test - 127 GF2 Main Control Board SW Version Number XX.YY.ZZ Service Test - 128 GF2 Main Control Board Flashmap Version Number Service Test - 129 Door UI SW Version Number Service Test - 130 Door UI Flashmap Version Number Service Test - 131 Door UI EEPROM Version Number Service Test - 132 Orion Isolated Micro SW Version Number Service Test - 133 Orion Isolated Flashmap Version Number Service Test - 134 Main UI SW Version Number Service Test - 135 Main UI Flashmap Version Number Service Test - 137 Wi-Fi SW Version Number Service Test - 138 Orion Non-Isolated SW Version Number Service Test - 139 Orion Non-Isolated Flashmap Version Number 2016. All rights reserved. 4 09/16

FOR SERVICE TECHNICIAN S USE ONLY W10832390C Assy: W10832398C W10832390C Assy: W10832398C Schematic DWG. No.: W10848890 Rev. C Rev C Wiring Diagram Rev C VOLTAGE TABLE P1 P1-1 P1-2 CONSTANT 115 VAC P2-2 P1-2 AIR BAFFLE FEEDBACK P2 P2-5 P1-2 AIR BAFFLE OUTPUT P2-6 P1-2 ICE MAKER DUCT CABINET HEATER AND FILTER 115 VAC P2-7 P1-2 FC DEFROST HEATER OUTPUT, W/ THERMOFUSE, 115V NOTE: This sheet contains important Technical Service Data FOR SERVICE TECHNICIAN ONLY DO NOT REMOVE OR DESTROY GF2 ORION P3-2 P1-1 FC DOOR RV MUST BE CLOSED = 115, OPEN = 0V P3-3 P1-2 ICE MAKER WATER VALVE P3 P3-5 P1-2 CONSTANT 115 VAC, AC LINE INTERLOCK P3-7 P3-8 130 VDC AUGER OUTPUT. LH RC DOOR CLOSED. ACTIVATE ICE PADDLE = 130-140 VDC P4-1 12.7 VDC CONSTANT 12.7 VDC P4 P4-3 COMMUNICATION WIN DATA P5-1 P5-2 5 VDC FC THERMISTOR OUTPUT = 1.5-5 VDC MAXIMUM P5 P5-3 P5-4 5 VDC RC THERMISTOR OUTPUT = 1.5-5 VDC MAXIMUM P6 P6-1 P6-2 12.7 VDC CONSTANT 12.7 VDC P7 P7-1 P7-2 5 VDC PANTRY THERMISTOR OUTPUT = 1.5-5 VDC MAXIMUM P8-1 P8-2 5 VDC RC EVAP THERMISTOR OUTPUT = 1.5-5 VDC MAXIMUM P8 P8-3 P8-4 5 VDC FC EVAP THERMISTOR OUTPUT = 1.5-5 VDC MAXIMUM P8-7 P8-8 12.7 VDC DC CONDENSOR FAN OUTPUT P9 P9-2 P9-3 12.7 VDC ICE BOX FAN OUTPUT TEST 36. SW3 TO ACTIVATE 01-12.7 VDC P12 P12-4 P12-2 115 VAC ISOLATION VALVE OUTPUT P14-1 P14-2 12.7 VDC FC FAN MOTOR P14 P14-3 P14-4 12.7 VDC RC FAN MOTOR P1-1 P1-2 CONSTANT 115 VAC P1 115 VAC P1-3 P1-4 P4 P4-1 P4-4 12.7 VDC NOT USED ORION SPARSH P4 P4-3 COMMUNICATION WIN DATA P7-1 P7-4 RC LEFT DOOR, SWITCH VOLTAGE = 12.7VDC, WHEN OPEN P7 P7-3 P7-4 RC RIGHT DOOR, SWITCH VOLTAGE = 12.7VDC, WHEN OPEN P8-1 P8-2 12.7 VDC LED OUT 12.7 VDC WHEN TURNED ON P8 P8-3 P8-4 12.7 VDC LED OUT 12.7 VDC WHEN TURNED ON P8-5 P8-6 12.7 VDC LED OUT 12.7 VDC WHEN TURNED ON P9-1 12.7 VDC CONSTANT 12.7 VDC P9 P9-2 P9-3 12.7 VDC PULSED 12.7 VDC P9-4 P9-5 12.7 VDC PULSED 12.7 VDC P15-1 VARIABLE FREQUENCY AND AMPLITUDE 115 VAC P15 P15-2 VARIABLE FREQUENCY AND AMPLITUDE 115 VAC P15-3 VARIABLE FREQUENCY AND AMPLITUDE 115 VAC P16-1 P16-8 P16-2 P16-7 P16 12.7 VDC CONSTANT 12.7 VDC P16-3 P16-6 P16-4 P16-5 J2-2 COMMUNICATION WIN DATA J2 J2-4 J2-1 12.7 VDC CONSTANT 12.7 VDC J7 J7-1 J7-2 FLIPPER MULLION HEATER OUTPUT TRITON J4 J5 J6 J8 J10 J4-1 J4-4 12.7 VDC CONSTANT 12.7 VDC J4-3 COMMUNICATION WIN DATA J5-1 CONSTANT 12.7 VDC J5-2 PULSED 12.7 VDC J5-3 PULSED 12.7 VDC J5-4 PULSED 12.7 VDC J5-5 PULSED 12.7 VDC J6-1 J6-3 12.7 VDC SWITCH VOLTAGE = 12.7 VDC, WHEN OPEN J6-4 J6-6 12.7 VDC SWITCH VOLTAGE = 12.7 VDC, WHEN OPEN J8-1 J8-2 DISPENSER HEATER, PULSED 12.7 VDC J8-3 J8-4 FILL TUBE HEATER, PULSED 12.7 VDC J8-5 J8-6 WATER VALVE, PULSED 12.7 VDC J10-1 J10-2 5 VDC ICE BOX THERMISTOR OUTPUT = 1.5-5 VDC MAXIMUM J10-3 J10-4 5 VDC ICE MAKER THERMISTOR OUTPUT = 1.5-5 VDC MAXIMUM J10-5 J10-6 12.7 VDC SWITCH VOLTAGE = 12.7 VDC, WHEN OPEN J10-7 J10-8 12.7 VDC SWITCH VOLTAGE = 12.7 VDC, WHEN OPEN J10-9 J10-10 12.7 VDC ICE MAKER MOTOR 2016. All rights reserved. 09/16