Medi-Minder Guardian USER MANUAL

Similar documents
MEDI-MINDER USER MANUAL

MEDI-MINDER USER MANUAL

CORPORATION PTY LTD MEDI-LINK

MEDI-LINK USER MANUAL

MEDI-CALL UNIT INSTALLATION MANUAL. Medi-Call V2.0 - V2.7 Installation Manual

Wireless Call Point ( )

TYNETEC. Telecare for independent living THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES MOBILE NETWORK

ALARM CONTROL PANEL AND DIALLER USER S MANUAL. Revision 4.5 A$15.00 INC GST. Ness D8 control panel User s manual

Smart Hub. User & Installation Guide

Smart Hub. Connecting people, connected care. What is it? Who is it for? How does it work?

SC-F3G User Manual 1.0

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

GX-Cubic1 Smart Care Medical Alarm Solutionon. Caring for Your Health and Personal Safety

SMARTWALK DEMENTIA WANDERING SYSTEM

GX-Cubic1 Smart Care Medical Alarm Solutionon. Caring for Your Health and Personal Safety

A Complete Smart Care Solution

Signature Series 418 Mhz COMMUNICATOR RECEIVER INSTALLATION AND OPERATIONS MANUAL

2 x CR123A Lithium batteries. White night-light LED. Blue alarm LED - also glows behind the lens. Ambient light sensor behind lens.

WIRELESS SOLUTIONS FOR RESIDENCES. A Group brand

NON-MONITORED EMERGENCY CALL SYSTEMS

ThinkPro Security and Automation Panel User Guide

Wander-Alarm DOORWAY SENSORS

User's MANUAL A$ Rev 1.4

Ness acomms Install & User Manual

CONTENTS. (User s Manual)

IRIS Touch 400 & 600 Range Installation Manual. Honeywell Galaxy Range. Version 2.0

English. Doro CareIP Mobile. User Guide

DualCom GradeShift UDL QUICK GUIDE & INSTRUCTION MANUAL

Now Compa ble With. VL Touchscreen Alarm. Crafted Touchscreen Security System that Revolutionizes Your World. illi tl C

DigiAir QUICK GUIDE & INSTRUCTION MANUAL

Tunstall Vi+ User Guide

Product List. Secure your Future... Choose Smartlink Products! Emergency Call & Care Systems Telephone Based Wireless Hardwired

ERS-3600B. PERS-3600B Personal Emergency Reporting System

2G & 3G GSM Portable PIR Alarm

Ness D8x / D16x ALARM CONTROL PANEL USER'S MANUAL. Revision 5.0 A$15.00

MK9 series CarePhone. Installers Mauual

ATS1235 Advanced Wireless DGP on 868 MHz AM Installation Sheet

Clino Guard. Intelligent Life Care. Solutions for safe and efficient care

A Complete Smart Care Solution

Wireless Alarm system s manual

Wireless Sensors. Security unplugged. Interlogix wireless sensors deliver reliable detection and flexible installation for multiple applications.


Independent Living without Leaving Home. Personal Emergency Reporting Systems from Linear

Q3000 Smart Home Alarm. Kit Content and Installation Guide

Q3200 Smart Home Alarm. Kit Content and Installation Guide

Elderly Care Alarm System

Panel XTO210/610/710 GPRS

Fall & Medical Alert Sensor

Automation. Smartphone Operation. Ness D8x / D16x alarm control panel. User's MANUAL. Revision 7.8.2

Connectivity: This is a stand-alone product; no Wi-Fi or other wireless connectivity.

YALE SECURE CONNECT. Delivering a premium digital locking solution with flexible control and peace of mind.

IC60 Sintony 60 Intrusion Control Panel

Installation and user guide

USER S MANUAL. Profile. MOBILE CALL GSM Alarm System

V1.0. Smart Home Alarm System. User Manual. APP download via QR Code scanning. Please read the manual carefully before using.

MEDICAL ALERT SETUP GUIDE

INTRUDER ALARM SOLUTIONS PRODUCT LIST 2012

Smart Security, Always Connected

Fratech Multipath-IP STU

F1 Smart Home Security Sensors. Unlocking the Potential of Your Wireless World

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

MINI RECEIVER. Installation and Operation Manual. Model # MR1214-MC 418 MHZ RECEIVER. Document #

Wolf Guard Touch Keypad GSM Wireless alarm system User s Manual

How to Build Visonic PowerMaster Wireless Alarm Systems

Smart Home Security Gateway Series

Quick Installation Manual LED Touch Keypad Autodial Wireless Alarm System

Honeywell Control Panels FOR RESIDENTIAL AND COMMERCIAL INSTALLATIONS. Feature Charts

PiSector GSM Cellular Wireless Alarm System

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

USER S MANUAL HOME ENERGY SAVINGS REMOTE CAMERA INTERNET USER INTERFACE TEMPERATURE ALARMS BURGLARY PROTECTION DOOR SECURITY FIRE SAFETY

GSM Alarm System. User s Manual. Profile. MOBILE CALL GSM Alarm System

ATSTORM v2. The sensor with FCES technology is connected to the interface with a communication cable.

MOBILE CALL GSM Alarm System User s Manual

Smart Home Security Gateway Series

PRODUCT CATALOGUE. Cape Town 18 Darter Road Blue Water Estate Kommetjie. Gauteng 245 Louis Botha Avenue Orchards Johannesburg

GSM RFID VOICE Alarm System

SECURE HOME SYSTEMS PLUG & PLAY... SECURE... AND WALK AWAY ONLY ALARMS TO BE RECOMMENDED BY THE NEIGHBOURHOOD WATCH

600 Range Dialer Installation Manual. Version 1.0

GSM Senior Guarder GSM SOS Call System GSM Elderly Guarder

SMARTWIRE MKII INSTALLATION MANUAL HARD-WIRED NURSE CALL SYSTEM. SmartWire MK2 Nurse Call Installation Manual v1.8.doc

installation & operation manual

MXD3G User Manual Revision 0 July 29, 2013

USER MANUAL QSDL503AD Intelligent Auto-Dial Alarm System

Carephone 52 Security You Can Feel

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

Any additional devices linked to the system ET08 (computer, sensors, relays etc.) must be approved by LST EN standard.

Security made in Germany

Remote switching machines with a SMS text from your mobile phone! Remote Monitoring your assets in the worldwide by your mobile Phone!

Sync. Smart Home Alarm

Your Lifeline Vi+ home unit. Your MyAmie pendant

COMMUNICATOR ET08 / ET081

IRIS Connect Series Quick Installation & Maintenance Guide. Version 1.1

1. Introduction. 2. Product overview

"Pegaso" wireless alarm system D.I.Y. wireless kit

GSM-SD WITH CALL,SMS,MMS MANUAL

SHEPHERD. Smart solutions to protect and manage what matters the most to you

Protect anything, anywhere, anytime.

Telemetry Communications Device. Installation Guide. Interface for the Emizon managed network. Issue 1: February 2008

GSM Emergency Alarm. User s Manual. For a better understanding of this porduct,please read this user manual thoroughly before using it.

ICP-CC488 ICP-CC488 EN. Control Panel. User s Guide

Transcription:

Medi-Minder Guardian USER MANUAL 1

Table of Contents TABLE OF CONTENTS...2 INTRODUCTION...2 MEDI-MINDER GUARDIAN...3 PENDANTS AND DETECTORS...4 USING MEDI-MINDER GUARDIAN... 4 DISPLAYS AND WARNINGS...6 CELLULAR SIGNAL QUALITY... 7 CELLULAR UDP/SERVER... 7 SPECIFICATIONS...8 Introduction Your SmartLink Medi-Minder Guardian has been designed provide you with the freedom and peace of mind in that, should you need assistance or HELP, it is available you 24 hours a day with the simple press of a Butn. The modern slim line design of the SmartLink Medi-Minder Guardian allows it be installed unobtrusively anywhere and is ready when you need help. HELP can be summoned by pressing a Butn on your personal Pendant or Wristwatch, which you can wear both inside your home or outside in the garden, ready for any emergency, giving you the freedom you enjoy for tal control at all times. The SmartLink Medi-Minder Guardian has been built the highest of technical standards for the protection of people and property and manufactured Australian and International quality standards. Your SmartLink Medi-Minder Guardian can be supplied with additional fixed or portable Radio Key Pendants, which can be worn or placed around the home as needed. Please contact your supplier for more information. 2

Medi-Minder Guardian Plug Pack 9V DC 300mA (Part No. 840-050) Direct Serial DB9 Pin Programming Lead (Part No. 450-185) Hardwird Inputs & Outputs Lead Assy 230mm 6 Way (Part No. 450-191) Rechargeable Battery 4.8V Ni-MH 1600mAh (Part No. 142-031) Common - Black Input 1 - Red Input2-White Output 1 - Green Output 2 - Brown Output 3 - Blue SIM Card RS232 Programming Aux Inputs/Outputs Battery ON-OFF Switch POWER 9VDC ONLY 3

Pendants and Detecrs Wrist/Neck Chain or Fixed Waterproof 2WayPendants (106-183) TWR Wall Mounted Wireless Call Point (100-841) Wireless Interface for PSA 240VAC Smoke Detecr (100-842) PSA 240VAC Smoke Detecr with 9V Rechargeable Battery (100-054) (915.8 927.2 MHz) Neck Chain or Wristwatch Waterproof VIBRATING 2 Way Pendant (106-223) TWR LUX PIR with inbuilt LED Night Light (Inactivity) (2 x CR123A 3V Batteries) (100-835) TWR Wireless Smoke Detecr (2 x CR123A 3V Batteries) (100-838) Using Medi-Minder Guardian NORMAL OPERATION Your Medi-Minder Guardian will normally look like this: The MAINS ON Light & the CANCEL (GREEN) BUTTON should be ON. 4

TO CALL FOR HELP You can make your Medi-Minder Guardian Call for Help by either: Pressing the HELP (RED) BUTTON on your Medi- Minder Guardian. 2 The HELP (RED) BUTTON will FLASH rapidly & Medi-Minder Guardian will start beeping. This is a Pre-Alarm warning, while this is sounding you can Cancel the Help alarm by pressing the CANCEL (GREEN) BUTTON on your Medi-Minder Guardian. 1 OR Pressing the Large HELP (Panic) BUTTON on your Wristwatch/ Pendant for 2 Seconds. If the CANCEL (GREEN) BUTTON is not pressed within the pre-alarm time (10 seconds), then your Medi-Minder Guardian will dial your Moniring Centre. 3 is displayed. OR Pressing the front or Side Lever HELP (Panic) Butn(s) on your Box Style Pendant for 2 Seconds. When your Moniring Centre has received the Help Call, your Medi-Minder Guardian will beep 7 times let you know that the Call has been received. The HELP (RED) BUTTON will now FLASHslowlyevery4seconds indicate that your Medi-Minder Guardian has Called for Help. 5

Displays and Warnings MAINS ON Light Flashing AC Power Fail Check/Make sure that the MAINS Power Plug Pack is plugged in and turned ON at the Power Point. or Flashing & BATTERY LOW Light Flashing - Check/Make sure that the BATTERY SWITCH is turned ON underneath the Medi- Minder Guardian. Contact your Installer/Moniring Centre. The Medi-Minder Guardian failed send a message Check/Make sure that the telephone lead is plugged in & all telephones are working. Contact your Installer/Moniring Centre. The CELLULAR has failed - Check/Make sure that the Antenna/SIM Card is plugged in. Contact your Moniring Centre. (The Medi-Minder Guardian will also beep for 25 seconds). is on the Display & HELP RED Butn Flashing The HELP RED Butn on the Medi-Minder Guardian has been Pressed. Flashing & HELP RED Butn Flashing Pendants No. 1 8 has been Pressed. Flashing & HELP RED Butn Flashing Pendants No. 1 8 has been Pressed. Flashing & HELP RED Butn Flashing Pendants No. 1 8 has been Pressed. Flashing & HELP RED Butn Flashing Pendants No. 1 8 has been Pressed. Flashing & HELP RED Butn Flashing Detecrs No. 1 8 Programmed as Fire Fi Option has been Activated. is on the Display Pendants No. 1 8 has detected a Low Battery. Contact your Installer/Moniring Centre. is on the Display Detecrs No. 1 8 has detected a Low Battery. Contact your Installer/Moniring Centre. 6

Cellular Signal Quality To Check the Signal Quality/Strength: While the Medi-Minder Guardian is in Normal/Operation Mode, Press the CANCEL Green Butn and the Signal Strength Displays/Flashes for 2 Seconds. The Medi-Minder Guardian Displays/Flashes the Signal Quality from 0 9 0 = Weakest Signal 5 = Average Signal 9 = Strongest Signal The 3G Unit Updates the Signal Quality/Strength Every Minute. Cellular UDP/Server Medi-Minder Guardian 3G The Medi-Minder Guardian 3G has an internal GPRS/GSM Module perform Network Reporting. This reporting is used transmit alarm reporting messages from a subscriber s site a Data Moniring Centre via a mobile data network and internet. The alarm reporting messages has packeted in ARMOR IP REPORTING PROTOCOL format, and use the UDP/IP internet procol transmit the alarm reporting message a Data Moniring Centre by specified Host/Server IP Address and Port Number. [ntwi] [ntw0] [prt0] [cnct] [rpt] [rsp] [ntwc ] [ntwc] Network Initiating Network Opening Port Opening UDP Connection Reporting Acknowledge Response Closes a Port on the Cellular Network Closes Connection with the Cellular Network. 7

Medi-Minder Guardian Specifications Dimensions Weight Quiescent Current 9V DC Plug Pack Battery Backup 2wayRadioReceiver Range L210 x W130 x D35 mm 590gms (including battery) 1mA 9V DC 300mA with integral earth (Part No. 840-050) 4.8V 1600mAh Rechargeable Ni-MH (Part No. 142-031) 2wayTWR 100 300 metres open air (Subject environmental conditions) Transmitter Type Frequency Power Output Crystal stabilised 915-928 MHz (Australian & New Zealand) < 100 uw (Or various international compliances) Conforming Standards IS09001/2000 AS4607 AS2201.4 (C2) AS4268.2012 International Quality manufacturing Standards Personal Response Systems Intruder Alarm Systems - Wireless Radio Equipment & Antenna Systems Short Range devices WARNING: For safety reasons, only connect equipment with a telecommunications compliance label. This includes cusmer equipment previously labelled permitted or certified. CopyrightSmartLink A division of NESS CORPORATION PTY LTD November 2016 SmartLink Medi-Minder Guardian User Manual Rev 1.01 Document Part Number : 890-468 For Product: Medi-Minder Guardian (106-224) Ness Corporation Pty Ltd ABN 28 069 984 372 Specifications may change without notice. To the best of our knowledge, the information contained in this manual is correct at the time of print. SmartLink A division of NESS CORPORATION P/L reserves the right make changes the features and specifications at any time without prior notice in the course of product development. 8