Similar documents
Experiment 2: Test on Domestic Refrigerator for evaluation of EER.

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES UNIT OBJECTIVES 3/22/2012

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

MECHANICAL ENGINEERING ME.2017 FUNDAMENTAL OF REFRIGERATION AND AIR CONDITIONING. Sample Questions and Answers

Life-Cycle Energy Costs and Greenhouse Gas Emissions for Gas Turbine Power

How is the heat transfer?

As we discussed early in the first chapter that heat can transfer through materials and the surrounding medium whenever temperature gradient exists

Gandhinagar Institute of Technology Mechanical Engineering (Thermal Engineering) Semester II. Design of Heat Exchange Equipments [ ]

Air-Cooling Evaporators

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Mechanical Engineering Department Sheet (1)

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

ijcrr Vol 04 issue 07 Category: Research Received on:06/02/12 Revised on:17/02/12 Accepted on:02/03/12

Design, Manufacturing of Chilled Water System for Process Cooling Application

AND AIR-CONDITIONING. Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University

Technical college/ Baghdad 4th Year Week No. :- 11. The objectives of this lesson are to: Introduction:

Enhancement of COP in Vapour Compression Refrigeration System

DEMONSTRATION OF A MICROCHANNEL HEAT EXCHANGER FOR OPERATION IN A REVERSIBLE HEAT PUMP SYSTEM

Design and Development of Water Cooled Condenser for Domestic Refrigerator

Performance of window air conditioner using alternative refrigerants with different configurations of capillary tube

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd

IJESRT. Scientific Journal Impact Factor: (ISRA), Impact Factor: 1.852

PERFORMANCE ENHANCEMENT OF AIR CONDITIONER *

EFFECT OF PAG OIL CIRCULATION RATE ON THE HEAT TRANSFER PERFORMANCE OF AIR-COOLED HEAT EXCHANGER IN CARBON DIOXIDE HEAT PUMP SYSTEM

A Generalized Correlation for Pressure Drop of Refrigerant R-134a through Helical Capillary Tubes

Global Journal of Engineering Science and Research Management

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System

Chapter 14, Problem 27.

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

Refrigeration Cycles MOHAMMAD FAISAL HAIDER. Bangladesh University of Engineering and Technology

Partial Load Performance Of Refrigeration System

Performance Optimization of the Evaporative Condenser Design

Performance Comparison of Hydronic Secondary Loop Heat Pump and Conventional Air-Source Heat Pump ABSTRACT 1. INTRODUCTION

[Mali*, 4.(12): December, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

Institute of Aeronautical Engineering (Autonomous) Dundigal, Hyderabad B.Tech (III II SEM) MECHANICAL ENGINEERING

HEAT EXCHANGERS. Heat exchangers are broadly classified based on the following considerations.

Figure 1: Overview of CO 2 evaporator types

Transcritical CO2 Bottle Cooler Development

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

Green economy with natural refrigerants

SECTION 5 COMMERCIAL REFRIGERATION UNIT 21 EVAPORATORS AND THE REFRIGERATION SYSTEM UNIT OBJECTIVES 3/22/2012 REFRIGERATION

Heat Exchanger. The purpose may be either to remove heat from a fluid or to add heat to a fluid.

Enhancement of COP by Using Spiral and Microchannel Condenser instead of conventional Condenser of VCR System

Chiller Plant Design. Julian R. de Bullet President debullet Consulting

Technical Development Program

Chapter 14 GAS VAPOR MIXTURES AND AIR-CONDITIONING

In the name of God. Jami Institute of Jami - Mehdi Rasti

FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points

Evaporators. Direct Expansion Flooded Recirculated Over Feed

COOLING / HEATING COILS

ISSN Vol.08,Issue.21, November-2016, Pages:

Energy Use in Refrigeration Systems

Experimental Investigation of a Hybrid Evacuated Tube Solar Collector

THE GATE COACH All Rights Reserved 28, Jia Sarai N.Delhi-16, ,-9998

Low GWP Refrigerants for Air Conditioning Applications

Evaporation System: Types and Design Aspects

PERFORMANCE ANALYSIS AND CALCULATION OF DIFFERENT PARAMETERS OF CONDENSER USING ANSYS FLUENT SOFTWARE

Experimental Investigation on Domestic Refrigerator by Shell and Tube Heat Exchanger after the Condenser Using Sub Colling of Refregaring Fluid

EXPERIMENTAL VERIFICATION OF PERFORMANCE OF CAPILLARY TUBE USING VAPOUR COMPRESSION REFRIGERATION SYSTEM

Week 9. Refrigeration Cycles I. GENESYS Laboratory

Water Cooled Condenser Using Nano Fluids

To Improve Cop of Domestic Refrigerator with the Help of Water Cooling Condenser

Thermodynamics II Chapter 5 Refrigeration

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

Midwest Industrial Initiative Webinar: Industrial Refrigeration

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

Design & Fabrication of Hybrid Cooler

Thermodynamics: Homework A Set 7 Jennifer West (2004)

Scientific Principals and Analytical Model. Charcoal Cooler. Lisa Crofoot MECH 425, Queens University

Enhancement of Round Tube and Flat Tube- Louver Fin Heat Exchanger Performance Using Deluge Water Cooling

COMPARING AIR COOLER RATINGS PART 1: Not All Rating Methods are Created Equal

E. Baffle Tray Column (or, Termed Shower Deck, No Holes, Caps, or Other Contact Devices)

Theoritical Analysis For Miniature Vapor Compression Cycle Performance Using Microchannel And Finned Tube Condenser

CHAPTER 7 COMPARISON OF HEAT EXCHANGERS

Figure 22-1 Evaporator sensible and latent capacity vs. entering air wet bulb

Forced Draft Air Coolers or Bunker Coils for Cold Storages

Dhulapally, Secunderabad Subject: REFRIGERATION AND AIR CONDITIONING QUESTION BANK

Pressure Enthalpy Charts

Seyedeh Sepideh Ghaffari 1 & Seyed Ali Jazayeri 2

Appendix 13. Categories of Cooling and Heating systems

AIM: TO STUDY THE PERFORMANCE OF THE DOMESTIC REFRIGERATION RIG.

9. ENERGY PERFORMANCE ASSESSMENT OF HVAC SYSTEMS

Economical and Energy Efficient Air Conditioner Using Calcium Liquid as a Secondary Refrigerant.

Design, Development & Testing of Double Pipe Heat Exchanger With Heat Transfer Enhancement Liners

[Vali*, 5(2): February, 2016] ISSN: (I2OR), Publication Impact Factor: 3.785

STUDY, ANALYSIS AND DESIGN OF AUTOMOBILE RADIATOR (HEAT EXCHANGER) PROPOSED WITH CAD DRAWINGS AND GEOMETRICAL MODEL OF THE FAN

Jurnal UMP Social Sciences and Technology Management Vol. 3, Issue. 3,2015

Techniques of Heat Transfer Enhancement and their Application. Chapter 4. Performance Evaluation Criteria for Two-Phase Heat Exchangers

Performance of an Improved Household Refrigerator/Freezer

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

A Review on Analysis of Vapour Compression Refrigeration System Using Matrix Heat Exchanger

Refrigerant Glide and Effect on Performances Declaration

Chapter 11 REFRIGERATION CYCLES

Performance of R-22, R-407C and R-410A at Constant Cooling Capacity in a 10

Case 13 Food Storage & Processing Center

Last exam / sista tent

U.G. Student, Department of Mechanical Engineering, J D Engineering College, Nagpur, Maharashtra, India

Theoretical Performance Analysis Of Direct Evaporative Cooler In Hot And Dry Climates

PERFORMANCE IMPROVEMENT OF SPLIT AIR CONDITIONER USING EVAPORATIVE COOLING METHOD IN THE CLIMATIC CONDITION OF GUWAHATI, ASSAM

Transcription:

Design Based Comparative Study of Several Condensers Komal B. Dabhi 1, Prof. S. B. Thakore 2 1 Chemical Engg. Dept., L. D. College of Engineering, Ahmedabad 380015 2 Chemical Engg. Dept., L. D. College of Engineering, Ahmedabad 380015 Abstract: Condenser is an important component of any refrigeration system. In this paper we have considered three different types of condenser based on the cooling medium, namely, Air Cooled Condenser, Water Cooled Condenser and Evaporative Cooled Condenser. The paper deals with detail design of the three condensers and their qualitative as well as quantitative comparison. Keyword: Air Cooled Condenser, Water Cooled Condenser, Evaporative Condenser, Design of Condenser, Comparison of Condensers 1. INTRODUCTION Condenser is an important component of any refrigeration system. In a typical refrigerant condenser, the refrigerant enters the condenser in a superheated state. It is first de-superheated and then condensed by rejecting heat to an external medium. The refrigerant may leave the condenser as a saturated or a sub-cooled liquid, depending upon the temperature of the external medium and design of the condenser. In actual refrigeration systems with a finite pressure drop in the condenser or in a system using a zeotropic refrigerant mixture, the temperature of the refrigerant changes during the condensation process also. However, at present for simplicity, it is assumed that the refrigerant used is a pure refrigerant and the condenser pressure remains constant during the condensation process. 2. CLASSIFICATION OF CONDENSER Based on the cooling medium used, condensers used in refrigeration systems can be classified into the following three categories: 1. Air-cooled condensers 2. Water-cooled condensers 3. Evaporative condensers 2.1 Air Cooled Condenser As the name implies, in air-cooled condensers air is the external fluid, i.e., the refrigerant rejects heat to air flowing over the condenser. Air-cooled condensers can be further classified into natural convection type or forced convection type. 2.1.1 Natural convection type: In natural convection type, heat transfer from the condenser is by buoyancy induced natural convection and radiation. Since the flow rate of air is small and the radiation heat transfer is also not very high, the combined heat transfer coefficient in these condensers is small. As a result a relatively large condensing surface is required to reject a given amount of heat. Hence these condensers are used for small capacity refrigerat ion systems like household refrigerators and freezers. The natural convection type condensers are either plate surface type or finned tube type. In plate surface type condensers used in small refrigerators and freezers, the refrigerant carrying tubes are a ttached 2142 www.ijariie.com 446

to the outer walls of the refrigerator. The whole body of the refrigerator (except the door) acts like a fin. Insulation is provided between the outer cover that acts like fin and the inner plastic cover of the refrigerator. It is for this reason that outer body of the refrigerator is always warm. Since the surface is warm, the problem of moisture condensation on the walls of the refrigerator does not arise in these systems. These condensers are sometimes called as flat back condensers. The finned type condensers are mounted either below the refrigerator at an angle or on the backside of the refrigerator. In case, it is mounted below, then the warm air rises up and to assist it an air envelope is formed by providing a jacket on backside of the refrigerator. The fin spacing is kept large to minimize the effect of fouling by dust and to allow air to flow freely with little resistance. In this design, the condenser tube (in serpentine form) was attached to a plate and the plate was mounted on the backside of the refrigerator. The plate acted like a fin and warm air rose up along it. Figure 1: Schematic of a wire-and-tube type condenser used in small refrigeration systems 2.1.2 Forced convection type: In forced convection type condensers, the circulation of air over the condenser surface is maintained by using a fan or a blower. These condensers normally use fins on air-side for good heat transfer. The fins can be either plate type or annular type. Figure 2 shows the schematic of a plate-fin type condenser. Forced convection type condensers are commonly used in window air conditioners, water coolers and packaged air conditioning plants. These are either chassis mounted or remote mounted. In chassis mounted type, the compressor, induction motor, condenser with condenser fan, accumulator, HP/LP cut- out switch and pressure gauges are mounted on a single chassis. It is called condensing unit of rated capacity. The components are matched to condense the required mass flow rate of refrigerant to meet the rated cooling capacity. 2142 www.ijariie.com 447

The remote mounted type, is either vertical or roof mounted horizontal type. Typically the air velocity varies between 2 m/s to 3.5 m/s for economic design with airflow rates of 12 to 20 cmm per ton of refrigeration (TR). The air specific heat is 1.005 kj/kg-k and density is 1.2 kg/m 3. Therefore for 1 TR the temperature rise Δt a = 3.5167/ (1.2x1.005 x 16/60) = 10.9 o C for average air flow rate of 16 cmm. Hence, the air temperature rises by 10 to 15 o C as compared to 3 to 6 o C for water in water cooled condensers. Figure 2: Forced convection plate fin and tube type condenser The area of the condenser seen from outside in the airflow direction is called face area. The velocity at the face is called face velocity. This is given by the volume flow rate divided by the face area. The face velocity is usually around 2m/s to 3.5 m/s to limit the pressure drop due to frictional resistance. The coils of the tube in the flow direction are called rows. A condenser may have two to eight rows of the tubes carrying the refrigerant. The moist air flows over the fins while the refrigerant flows inside the tubes. The fins are usually of aluminum and tubes are made of copper. Holes of diameter slightly less than the tube diameter are punched in the plates and plates are slid over the tube bank. Then the copper tubes are pressurized which expands the tubes and makes a good thermal contact between the tube and fins. This process is also known as bulleting. For ammonia condensers mild steel tubes with mild steel fins are used. In this case the fins are either welded or galvanizing is done to make a good thermal contact between fin and tube. In case of ammonia, annular crimpled spiral fins are also used over individual tubes instead of flat-plate fins. In finned tube heat exchangers the fin spacing may vary from 3 to 7 fins per cm. The secondary surface area is 10 to 30 times the bare pipe area hence; the finned coils are very compact and have smaller weight. 2.2 Water Cooled Condenser In water cooled condensers water is the external fluid. Depending upon the construction, water cooled condensers can be further classified into: 1. Double pipe or tube-in-tube type 2. Shell-and-coil type 3. Shell-and-tube type 2142 www.ijariie.com 448

2.2.1 Double Pipe or tube-in-tube type: Double pipe condensers are normally used up to 10 TR capacity. These condensers the cold water flows through the inner tube, while the refrigerant flows through the annulus in counter flow. Headers are used at both the ends to make the length of the condenser small and reduce pressure drop. The refrigerant in the annulus rejects a part of its heat to the surroundings by free convection and radiation. The heat transfer coefficient is usually low because of poor liquid refrigerant drainage if the tubes are long. 2.2.2 Shell-and-coil type: These condensers are used in systems up to 50 TR capacity. The water flows through multiple coils, which may have fins to increase the heat transfer coefficient. The refrigerant flows through the shell. In smaller capacity condensers, refrigerant flows through coils while water flows through the shell. When water flows through the coils, cleaning is done by circulating suitable chemicals through the coils. 2.2.3 Shell-and-tube type: This is the most common type of condenser used in systems from 2 TR upto thousands of TR capacity. In these condensers the refrigerant flows through the shell while water flows through the tubes in single to four passes. The condensed refrigerant collects at the bottom of the shell. The coldest water contacts the liquid refrigerant so that some subcooling can also be obtained. The liquid refrigerant is drained from the bottom to the receiver. There might be a vent connecting the receiver to the condenser for smooth drainage of liquid refrigerant. The shell also acts as a receiver. Further the refrigerant also rejects heat to the surroundings from the shell. The most common type is horizontal shell type. Vertical shell-and-tube type condensers are usually used with ammonia in large capacity systems so that cleaning of the tubes is possible from top while the plant is running. 2.3 Evaporative condenser Figure 3: Shell and tube In evaporative condensers, both air and water are used to extract heat from the condensing refrigerant. Figure 4 shows the schematic of an evaporative condenser. Evaporative condensers combine the features of a cooling tower 2142 www.ijariie.com 449

and water-cooled condenser in a single unit. In these condensers, the water is sprayed from top part on a bank of tubes carrying the refrigerant and air is induced upwards. There is a thin water film around the condenser tubes from which evaporative cooling takes place. The heat transfer coefficient for evaporative cooling is very large. Hence, the refrigeration system can be operated at low condensing temperatures (about 11 to 13 K above the wet bulb temperature of air). The water spray countercurrent to the airflow acts as cooling tower. The role of air is primarily to increase the rate of evaporation of water. The required air flow rates are in the range of 350 to 500 m 3 /h per TR of refrigeration capacity. 3. CASE STUDY Figure 4: Schematic of evaporative condenser Case Study 1 (Water Cooled Condenser) A chilling plant is designed to achieving 703 kw ( 200 TR) heat exchange capacity to supply aqueous ethylene glycol brine at -25 C by evaporating liquid ammonia in the evaporator at -33.3 C (and 1 atm.). Ammonia vapor at - 28 C leave the evaporator and sent to compressor. In first alternative, a shell and tube heat exchanger (BEM) is considered as condenser. Superheated ammonia vapor at 120 C and at 16.435 bar a from the compressor enters the shell of the condenser at 42 C. Cooling water enters the tubes at 32 C and leaves at 38 C. For this duty design a BEM type horizontal condenser. Consider the tube OD and length as 19.05 mm (16 BWG) and 2.4383 m (8 ft) respectively. Triangular pitch = 1.25d o Case Study 2 (Air Cooled Condenser) An air cooler is considered for condensing ammonia. Ambient air at 45 C is supplied to the condenser while ammonia is condensed at 60 C in the tubes. Compressed ammonia gas enters the condenser at 130 C. A pressure drop of 15 kpa is permitted in the condenser. Condenser will have two pass arrangements in finned tubes and leaves from top at 50 C. each horizontal tube row can be considered as a pass. Effective tube details: SS 304 with OD = 19.05 mm and triangular pitch of 43 mm Fin details: Type fin : Spiral wound transverse fins, SS 304 MOC, Fin OD = 38 mm 8 fins per linear inch and fin thickness = 0.889 mm Tube length = 3 m Width of air cooler = 3 m 2142 www.ijariie.com 450

Design of an air cooler for ammonia condensation duty. Case Study 3 (Evaporative Condenser) An evaporative condenser is considered for condensing ammonia. An evaporative condenser is basically a rectangular tube bundle installed in cooling tower. Cooling tower falls over the tubes at a required rate at essentially a constant temperature; 4.5 C above the design wet bulb temperature of air. Ambient air at 40 C dry bulb temperature (DB) and 28 C wet bulb temperature (WB) is supplied from sides of the tower. An induced draft fan sucks the air from the louvers and discharges it from top with 95% relative humidity (RH). Ammonia gas enters at 120 C the tubes and condenses at 1.5 C higher that the cooling water temperature. Design the tube bundle to be placed in the evaporative condenser. For the evaporation of water film over tube bundle, heat transfer coefficient can be determined by Kallam s equitation. h o = 7.3 x 10-9 x N 0.05 ( ) where, h o = heat transfer coefficient, W/(m 2. C) Parameters to be calculated Water Cooled Condenser Air Cooled Condenser Evaporative Condenser Total heat duty of condenser 905.2 917.797 897.45 kw Heat duty for desuperheating zone de 159.6 168.825 155.303 kw Heat duty for condensation zone c 745.6 748.972 742.45 kw Circulation rate of ammonia ṁ a 2462.8 2703.56 2372.11 kg/h Circulation rate of water /air ṁ w /ṁ air 129724 515196 1332 kg/h Mean temp. difference for desuperheating T mde 27.62 37.83 21.15 C zone Mean temp. difference for condesation zone T mc 7.25 14.133 1.5 C Tube side heat transfer coefficient h i For desuperheating zone 6576.12 434.4 370.45 W/m 2. C For condensation zone 6673.36 6556.2 W/m 2. C Shell side heat transfer coefficient for h o 223.2 196.3 12071 W/m 2. C desuperheating zone Shell side heat transfer coefficient for h oc 11910.4 1240.5 W/m 2. C condensation zone Overall heat transfer coefficient for U ode 190.3 302.3 248.5 W/m 2. C desuperheating zone overall heat transfer coefficient for U oc 1165.28 865.07 1327.4 W/m 2. C condensation zone Area required for desuperheating zone A rde 30.36 14.726 29.55 m 2 Area required for condensation zone A rc 88.155 61.26 372.88 m 2 Total area required A r 118.515 76.03 402.43 m 2 Area provided A pr 136.59 86.773 457.64 m 2 Excess area 15.25% 14.213% 13.720% Tube side pressure drop P t 69.6 kpa Shell pressure drop /Air side pressure drop P s 0.2849 3.255 kpa Table 1: Summary of Design results of three condensers 4. CONCLUSION From the results it is conclude that the heat duties for desuperheating and condensation descends in the order of Air Cooled Condenser, Water Cooled Condenser and Evaporative Condenser, this implies that the overall heat duty for Evaporative Condenser is the least. The circulation rate for Ammonia and Water is also least for evaporative condenser; in fact it is 100 times less for water circulation rate for water cooled evaporator and 386 times less from air cooled. 2142 www.ijariie.com 451

The Tube side heat transfer coefficient is maximum for Water cooled evaporator and minimum for evaporative condenser on the other hand for condensation the tube side heat transfer coefficient is higher for air cooled condenser. The Shell side heat transfer coefficient for desuperheating zone is highest for evaporative condenser and lowest for Air Cooled Condenser, on the flip side the Shell side heat transfer coefficient for condensation zone is highest for Water Cooled Condenser. Therefore, Overall heat transfer coefficient for desuperheating zone and condensation zone is falling in between the Air Cooled Condenser and the Water Cooled Condenser for evaporative condenser. Here, it is evident from the results that the heat transfer area required is greatest for evaporative condenser. 5. REFERENCES [1] Donald.Q. Kern Process Heat Transfer Chapter 20, Page 738 [2] Shuchen B Thakore Introduction to Process Engineering and Design, Page 149-363 [3] Shan K. Wang Handbook of Air Conditioning and refrigeration (second edition) 10.22-10.33 [4] Robert H. Perry, Don W. Green & James O. Maloney Perry s Chemical Engineers Handbook 7 th edition Heat Transfer Equipment Section-11, 11-29 [5] M. Hosoz and A. Kilicarslan, Performance evaluations of refrigeration systems with air-cooled, water-cooled and evaporative condensers International Journal Of Energy Research 2004; 28:683 696 (DOI: 10.1002/er.990) [6] E. Hajidavalloo, H. Eghtedari, Performance improvement of air-cooled refrigeration system by using evaporatively cooled air condenser International journal of refrigeration 33 (2010) 982 988 [7] Shah D. Parin and Sahajpal Shreya, Resource conservation through thermal design of evaporative condensers Journal of Environmental Research And Development Vol. 8 No. 2, October-December 2013 [8] Kyle A. Manske, Performance Optimization of Industrial Refrigeration Systems University of Wisconsin- Madison 1999 2142 www.ijariie.com 452