Series 3000 XPIS -wire loop powered toxic and Oxygen gas detector for use in potentially explosive atmospheres
Series 3000 XPIS Reliable detection Proven electrochemical sensing technology Uses Surecell electrochemical cells, ideal for hot and humid environments Long life sensing elements (typical > years) Patented Reflex sensing element verification diagnostics Reduced installation costs Universal mounting bracket included supplied as standard Flameproof transmitter allows field wiring to be run along with other non IS instruments Plug-in sensor removes wiring Reduced commissioning costs Sensor recognition software auto configures transmitter Non-intrusive configuration Plug and play factory configured sensors Reduced maintenance costs IS sensor connection permits hot swap, reducing down time User programmable calibration frequency Integral fault diagnostic software Menu / icon driven calibration procedure Regulatory compliance European (ATEX) US (UL) Canadian (c-ul) International (IECEx) Range of optional accessories Remote sensor mounting kit Duct mounting kit (for H, CO and H S only) Calibration cup to apply test gas Collecting cone (for H and CO only) Typical applications Exploration and drilling platform Production platforms Onshore oil and gas terminals Refineries and chemical plants Power plants Waste water facilities Utilities The Series 3000 XPIS provides comprehensive monitoring of toxic and Oxygen gas hazards in potentially explosive atmospheres, both in and out of doors. This low powered gas detector operates on an industry standard -wire 4-0mA loop, making it ideal for both new and retrofit applications. Users can configure the detector without the need of a hot work permit by using the LCD and magnetic switches. Fault diagnostic software and programmable calibration due frequency simplifies maintenance procedures. The intrinsically safe smart sensors are supplied pre-configured and can be hot swapped without having to remove power to the detector, saving time and money during commissioning and routine servicing. A remote sensor mounting kit is available that allows the sensor to be mounted up to 50 (5m) from the transmitter, making it ideal for operation in areas that are difficult to access. Series 3000 XPIS is supplied with all necessary accessories for easy installation. The detector can be mounted on a wall or support pole using the universal bracket provided. Electrical installation can be made using either conduit or cable with suitable mechanical protection. A ¾ NPT entry and M0 adaptor are included as standard. A weatherproof cap is also included for use in the harshest outdoor conditions.
Installation Mechanical Installation Options Series 3000 XPIS is designed for use in potentially explosive atmospheres. As such, installation should follow national guidelines using suitable mechanically protected cable and glands (M0 or ¾ NPT) or conduit (¾ NPT). Use 0.5mm (0AWG) to.0mm (~4AWG) cross sectional area cable as needed to ensure minimum operating voltage at the detector, depending on installed cable length. Various accessories are available for different applications. Duct Mount Pipe Mounting Wall Mount Remote Mounting Electrical Connections Dimensions Remote Mounting Arrangement 50.0mm / 5.9" Earth Ground 4.0mm 3." 80.0mm / 85.0mm / 7.3" 5.0mm 5 Terminal Detector Controller Number Terminal Connection 5 M4 Screw + - M5 Screw Typical Maximum Installed Cable Lengths 50.0mm The maximum cable length between a controller and detector is dependent upon: Wiring Schematics The minimum guaranteed supply voltage to the detector at the controller (V C ). The minimum operating voltage of the detector (V d ) The maximum current draw of the detector (I m ) The input impedance of the controller (R L ) The resistance of the cable (R C ) Using the example values opposite, the table below shows typical cable lengths. For a specific application, the cable manufacturer s resistance data for a specific cable type must be used. A cable length calculation formula can be found in the detector s product technical manual. Maximum Cable Length km (m) Cable Size Cable Cable distance km (m) Cable distance km (m) Resistance where the Input where the Input R c Ω/km Impedance Impedance (Ω/m) R L = 33Ω R L = 50Ω 0.5mm (0AWG*) 36.8 (59.) 3.9 (6.3) 0.9 (.0).0mm (7AWG*) 9.5 (3.4) 7.3 (.7).7 (.7).5mm (6AWG*).7 (0.4). (8.0).7 (4.3).0mm (4AWG*) 0. (6.3) 4. (.7) 3.4 (5.5) Detector supply V d Assumed to be 7Vdc Maximum detector signal I m Assumed to be ma (over range) Cable resistance R c Subject to cable type Load resistor of control panel R L Assumed 33Ω (min) or 50Ω (max) Subject to controller manufacturer Controller supply voltage V c Subject to controller manufacturer Assumed nominal of 4Vdc V c V c Controller R L -VE Controller R L -VE 3 R c R c I m I m 3 Detector Detector -VE V d V d * Nearest equivalent
Technical Summary Series 3000 XPIS Detector Use Rugged and reliable gas detector for the protection of personnel from toxic and Oxygen gas hazards. Suitable for use in Zone or hazardous areas and North American Class I and II Division or areas. Detectable Gases Gas Selectable full Default range scale range Oxygen 5.0%/Vol only 5%Vol Carbon Monoxide 00 to,000ppm 300ppm Hydrogen Sulphide 0 to 50ppm 5ppm Hydrogen Sulphide 50 to 500ppm 00ppm Chlorine 5 to 0ppm 5ppm Ozone 0 to 0.4ppm only 0.4ppm Sulphur Dioxide 5.0 to 0.0ppm 5ppm Chlorine Dioxide 0 to ppm only ppm Nitrogen Monoxide 0 to 00ppm 00ppm Nitrogen Dioxide 5 to 50ppm 0ppm Hydrogen 0 to 000ppm only 000ppm Hydrogen 0 to 0,000ppm only 0,000ppm Hydrogen Chloride 0 to 0ppm 0ppm Hydrogen Cyanide 0 to 0ppm only 0ppm Hydrogen Fluoride 0 to ppm only ppm Ammonia* 50 to 00ppm 00ppm Ammonia* 00 to,000ppm,000ppm Phosphine 0 to.ppm only.ppm Electrical Connections and Power Recommended Cable -wire loop powered 7Vdc (+/-0%) to 4Vdc (max) operation ma max. over range -wire with screen (90% coverage) or conduit 0.5mm (0AWG) to.0mm (4AWG) 0-00%FSD 4-0mA Fault = 3mA Calibration due selectable off or 3mA Max. over range ma Inhibit (toxic sensors) = Selectable 3mA or 4mA Inhibit (Oxygen sensors) = Selectable 3mA or 7.4mA Construction Material Maximum Dimensions Weight Transmitter: Painted aluminium ADC, Sensor: 36 stainless steel with PTFE filter 50 x 85 x 80mm 5.9 x 7.3 x 3. inches (excluding mounting bracket) 450g (3.3lbs) Environmental IP Rating Operating Temperature Operating Humidity Operating Pressure Storage Conditions Certification Approvals IP66 (EN6059:99), NEMA 4X -0 C to +55 C (-4 F to 3 F) -0 O C to +40 O C (-4 O F to +04 O F) NH 3 Sensor Continuous 0-90% RH (non-condensing) Intermittent 0-99% RH (non-condensing) 90-0kPa 5 C to 30 C (59 F to 86 F) 30-70%RH (non-condensing) UL/c-UL Class l Div &, Groups B, C & D -40 C to +55 C UL/c-UL Class ll Div &, Groups E, F & G -40 C to +55 C ATEX II G Ex d [ia] IIB+H T4 (Tamb -0 C to +55 C/ -4 F to 3 F) IECEx Ex d [ia] IIB+H T4 CE compliant in accordance with: EMC Directive 89/336/EEC as amended by 9/3/EEC ATEX Directive 94/9/EC * Suitable for applications without NH 3 ambient background concentrations only.
Ordering Information Ordering Information A complete assembly consists of two parts, a transmitter and sensor which must be ordered separately. Transmitter PN#: Two certified versions are available: - S3KAX ATEX and IECEx certified S3KUX UL and CSA (c-ul) certified Sensor PN#: All certified ATEX, IECEx, UL, CSA (c-ul) with two digits to specify gas type and range: - e.g. S3KXXCSS (C denotes Carbon Monoxide, with a default range of 0-300ppm and user configurable for ranges from 0-00ppm to 0-999ppm) Transmitter S3KXX Series 3000 XPIS transmitter is supplied complete with wall or pipe mounting bracket, x ¾ NPT cable entry, x ¾ NPT to M0 adaptor, x hex wrench set, weatherproof cover, operating magnet, configuration / test certificate and instruction manual. Units are 00% inspected prior to despatch from the factory. Order the required sensor separately. Sensor Part Numbers and Available Gases S3KXSOSS S3KXSCSS S3KXSHSS S3KXSHSS S3KXSLSS S3KXSZSS S3KXSSSS S3KXSXSS S3KXSMSS S3KXSNSS S3KXSGSS S3KXSGSS S3KXSRSS S3KXSYSS S3KXSFSS S3KXSASS S3KXSASS S3KXSPSS Oxygen 0-5%VOL Carbon Monoxide 0-300ppm (default) 0-00 to 0-999ppm selectable Hydrogen Sulphide 0-5ppm (default) 0-0 to 0-50ppm selectable Hydrogen Sulphide 0-00ppm (default) 0-50 to 0-500ppm selectable Chlorine 0-5ppm (default) 0-5 to 0-0ppm selectable Ozone 0-0.4ppm (default) 0-0.4 only Sulphur Dioxide 0-5ppm (default) 0-5 to 0-0ppm selectable Chlorine Dioxide 0-ppm (default) 0-ppm selectable Nitrogen Monoxide 0-00ppm (default) 0-00ppm selectable Nitrogen Dioxide 0-0ppm (default) 0-5 to 0-50ppm selectable Hydrogen 0-000ppm (default) 0-000ppm selectable Hydrogen 0-0,000 (default) 0-0,000 selectable Hydrogen Chloride 0-0ppm (default) 0-0 to 0-0ppm selectable Hydrogen Cyanide 0-0ppm (default) 0-0ppm selectable Hydrogen Fluoride 0-ppm (default) 0-ppm selectable Ammonia 0-00ppm (default) 0-50 to 0-00ppm selectable Ammonia 0-000ppm (default) 0-00 to 0-,000ppm selectable Phosphine 0-.ppm (default) 0-.ppm selectable Shipping Details Shipping carton dimensions: L35mm (.4 ) x W30mm (9.0 ) x D5mm (4.5 ) Approximate weight:.5kg (3.3lbs) Optional Accessories S3KCAL SPPPCC S3KDMK S3KRMK Calibration Gases Calibration gas flow housing Collecting cone for use with lighter than air gases (H and CO only**) Duct mounting kit (H, CO & H S only**) Remote sensor mounting kit includes: enclosure with sensor socket, 5m of digital cable and glands, transmitter cable plug, mounting screws Contact Honeywell Analytics representative Note: ** Contact a Honeywell Analytics representative for the suitbalitiy of accessories for other gases.
Our Product Range Fixed Gas Monitoring Honeywell Analytics offers a wide range of fixed gas detection solutions for a diverse array of industries and applications including: Commercial properties, industrial applications, semiconductor manufacturers, energy plants and petrochemical sites. Detection of flammable, oxygen and toxic gases (including exotics) Innovative use of 4 core sensing technologies paper tape, electrochemical cell, catalytic bead and infrared Capability to detect down to Parts Per Billion (ppb) or Percent by Volume (%v/v) Cost effective regulatory compliance solutions Portable Gas Monitoring When it comes to personal protection from gas hazards, Honeywell Analytics has a wide range of reliable solutions ideally suited for use in confined or enclosed spaces. These include: Detection of flammable, oxygen and toxic gases Single gas personal monitors worn by the individual Multi-gas portable gas monitors used for confined space entry and regulatory compliance Multi-gas transportable monitors used for temporary protection of area during site construction and maintenance activities Technical Services At Honeywell Analytics, we believe in the value of great service and customer care. Our key commitment is providing complete and total customer satisfaction. Here are just a few of the services we can offer: Full technical support Expert team on hand to answer questions and queries Fully equipped workshops to ensure quick turnaround on repairs Comprehensive service engineer network Training on product use and maintenance Mobile calibration service Customised programmes of preventative/corrective maintenance Extended warranties on products Find out more www.honeywellanalytics.com Contact Honeywell Analytics: Europe, Middle East, Africa Life Safety Distribution AG Wilstrasse -U3 CH-860 Uster Switzerland Tel: +4 (0)44 943 4300 Fax: +4 (0)44 943 4398 gasdetection@honeywell.com Americas Honeywell Analytics Distribution, Inc. 405 Barclay Blvd. Lincolnshire, IL 60069 USA Tel: + 847 955 800 Toll free: + 800 538 0363 Fax: + 847 955 808 detectgas@honeywell.com Asia Pacific Honeywell Analytics Asia Pacific #508, Kolon Science Valley () 87-0 Guro-Dong, Guro-Gu Seoul, 5-050, Korea Tel: +8 (0) 05 0307 Fax: +8 (0) 05 039 analytics.ap@honeywell.com Technical Services ha.emea.service@honeywell.com www.honeywell.com Please Note: While every effort has been made to ensure accuracy in this publication, no responsibility can be accepted for errors or omissions. Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently issued regulations, standards, and guidelines. This publication is not intended to form the basis of a contract. H_Series 3000_DS0057_V_EMEA 0/07 007 Honeywell Analytics 3