Incident Summary (Reference # ) (DRAFT)

Similar documents
Incident Summary (II )

Incident Summary (Reference # II )

Incident Summary #II (#8165) (FINAL)

Incident Summary (Reference # )

Preventing Hydraulic Shock: Millard Refrigerated Services, Inc. Anhydrous Ammonia Release

Refrigeration System Overview. ASTI 32 Hour Managing Ammonia Course September 27 30, 2016

YOUR BASIC REFRIGERAION SYSTEM SVASD MAY 26, 2011

The cold chain in the fishery sector. Refrigeration Technology Review

THE BIG FIVE NATURAL REFRIGERANTS IN DIFFERENT INDUSTRIAL APPLICATIONS. MAYEKAWA EUROPE S.A.,Leuvensesteenweg 605, 1930 Zaventem, Belgium

INVESTIGATION FINDINGS III IMPACT OF INADEQUATE VENTILATION AND DISCHARGE SYSTEMS

HVAC Basics RESIDENTIAL AIR CONDITIONING

Case 15 Refrigeration System for Chemical Fertilizer Plant Ammonia Storage

Use of Dispersion Modeling Software In Ammonia Refrigeration Facility Design. By: Martin L. Timm, PE Corporate Process Safety Manager

Applying the Frick Low Charge Central System to a New Freezer/Cooler Facility

Dual Column Dehydrating Breather Manual

Fabrication of Hot and Cold Water Dispenser

Incident Summary (Reference # )

Safe Handling of Ammonia & Reporting Leaks. Andrew Keeley, Senior Project Professional

ACKNOWLEDGEMENT. IIAR expresses its deepest appreciation to these authors for their contributions for the betterment of the industry.

Ammonia Release Incidents ( )

Providing Solutions. Simplifying Regulation. IIAR Standards. Peter Thomas, P.E., CSP Resource Compliance, Inc.

Installation and Maintenance Manual Please retain this manual for future reference.

Fundamental Principles of Air Conditioners for Information Technology

Salinas Valley Ammonia Safety Day. May 26, 2011 Salinas, CA

568X, 587X, 588X Series

Ammonia. Background on ammonia as a refrigerant

CIRRUS AIRPLANE MAINTENANCE MANUAL

HEATING AND AIR CONDITIONING

Columbia Boiler Company

Phillips. HORIZONTAL AND VERTICAL ASSEMBLIES For Ammonia (R-717) and Halocarbon Refrigerants

Refrigerant Recovery Machine. Model No Operating Manual

Survey of electrical equipment installed in hazardous areas on tankers

Effective Handling of Air, Water, and Oil in Ammonia Refrigeration Systems to Conserve Energy

HEATING AND AIR CONDITIONING

General Purpose Ventilation Fan - Venturi-Style Blower PSIG

OPER LV Wheeler Way

Ammonia Detection System Codes and Design Specifications

Thermostatic expansion valves for ammonia Type TEA

EQUIPMENT CARE AND CLEANING

REFRIGERATION SUPPLY. A company of Bayer and LANXESS

ONE PIECE TOILET LT3. Model: MPN: B0940 INSTALLATION INSTRUCTIONS. Version: 1.0

MECHANICAL SCIENCE Module 2 Heat Exchangers

LGCNCOE Study Guide: Fixed Gas Detection

Hazard Zone Locations: HAZARD ZONE CHECKLIST

Scale Prevention for Evaporative Condensers. Maintaining Efficiency and Reducing Costs

UNDERSTANDING ELECTRICAL SAFETY RISKS

OIL/WATER SEPARATORS. Compressed Air & Process Filtration

THE TRUTH ABOUT SMART METER FIRES AND FAILURES IN BRITISH COLUMBIA

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd

RHP & FHP Series. High Pressure Air Treatment Global Air Treatment

Operating Manual. Model: 1400 Model: 1400-N RIFOmat Float-Controlled Condensate Traps, PN Safety instructions. 2 General description and use

Flammable Liquid: A liquid whose flashpoint is greaterless than 100 F when tested by closed-cup test methods.

WATLOW IND. WATROD Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2.00

Figure 17-1 Residential air conditioner (Image courtesy of Bryant Heating & Cooling Systems)

Life-Cycle Energy Costs and Greenhouse Gas Emissions for Gas Turbine Power

CFF-500 CHILLER. Operator s & Installation Manual. Release Date: November 3, 1996 Publication Number: Revision Date: March 25, 2014 Revision: F

WATLOW IND. FIREBAR Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

SECTION PACKAGED COMPRESSOR AND CONDENSER UNITS

569, 570, 571, 572 Series

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

NABTEB Past Questions and Answers - Uploaded online

569, 570, 571, 572 Series

Welcome! Today s topic: Small Home Repairs. November 14, 2015

Walk-in Refrigerated Rooms. An Overview of Requirements, Options and Construction Details

E.2 series high efficiency circulator. Installation and operating instructions

Cased Aluminum Coils "Dedicated Upflow / Downflow" Convertible to horizontal with separately purchased kit

Technical Development Program

Installation and Operation Guide For

INTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O 4/19/2012

Overview of New Refrigerants and Expected Market Trends

Refrigeration Basics from a Brewery Perspective

Intermediate Refrigeration Systems for Operators

DRYAIRE DESICCANT SYSTEM MODEL 6760

Presentation to. IOSH Food and Drink Group. Danny McDougall Richard Perkin

1. PURPOSE This standard specifies safe design, construction, installation, and operation of refrigeration systems.

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

RAGAGEP UPDATE. Douglas Reindl, Director, IRC 2016 IRC R&T Forum

Liquid Drainers LIQUID DRAINERS

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES UNIT OBJECTIVES 3/22/2012

The Electronic Newsletter of The Industrial Refrigeration Consortium Vol. 11 No. 1, 2011

EcoVision II Plus Door Upgrade for D6 Kysor Warren Multi-deck Merchandisers

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

SEALED ENCLOSURE COOLING

BLAST-IT-ALL BUMPER BLASTER

INSTALLATION INSTRUCTIONS

K4600 Assembly Directions

EUPEN CONNECTOR INSTALLATION MANUAL 50 & TRADITION

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

ACT-HSC Series Heat Sink Coolers Sealed Enclosure Cooling Installation Guide

MV THOMSON MAJESTY Engine-room fire South of Gorgona Island 21 October 2016

Automotive Air Conditioning systems

Installation and operating instructions. E.2 Series high efficiency circulator

HT650 TM FAN DRIVE SERVICE INSTRUCTIONS

INSTALLATION INSTRUCTIONS TXV Coils EBD, EBA

INSTALLATION INSTRUCTIONS TXV Coils EBU, EBA

Disposal Unit (BKSDU) Burger King Shortening. Operation, Service & Parts Manual BURGER KING BKSDU

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER

Incident Summary #II (#9286) (FINAL)

UreaKnowHow Leak Detection System

Transcription:

Incident Summary (Reference #5616609) (DRAFT) Incident Date May 24 2017 Location Regulated industry sector South Surrey Refrigeration system SUPPORTING INFORMATION Impact Injury Damage Incident rating Qty injuries 0 Injury description Injury rating Damage description Damage rating None None Man hole gasket seal failed resulting in release of approximately 16lbs of ammonia (NH3) in the machine room Moderate Moderate Incident overview Manhole gasket seal on an oil separator pressure vessel failed to hold ammonia in the vessel which resulted in the exhaust ventilation system to be activated. Frozen food storage facility has a mechanical room separate and self-contained from the warehouse. INVESTIGATION CONCLUSIONS Site, system and components In an ammonia refrigeration system, ammonia in a gas state is compressed from the compressor to high pressure high temperature ammonia gas. The compressed gas heats as its pressurised. The hot gas enters an oil separator where the ammonia gas and compressor oil is separated so that oil is not carried over with the ammonia gas to the coils and other components. The hot ammonia gas is directed to the coils where the refrigerant gas dissipates its heat. The ammonia gas condenses into ammonia liquid at high temperature. The high pressure liquid flows through the expansion valve where the ammonia immediately boils and vaporizes which causes the refrigerate effect. The low temperature low pressure ammonia gas is directed back to the compressor to complete and repeat the cycle. The sensors are programmed to detect an ammonia release and activate an exhaust ventilation system. The exhaust system is capable of exhausting 18 room air changes per hour. The pressure vessel (oil separator) is fitted with a manhole hatch for maintenance and inspection. A gasket is needed to provide a tight seal between the manhole cover and base metal to prevent escaping gasses from the vessel. The manhole cover is elliptical in shape and is held to the seat with two yokes and bolts. Failure scenario(s) New compressor addition to ammonia system installed in 2016, within 1 year of the installation a leak developed at the lower half of the manhole access from a factory installed gasket. Facts and evidence BRITISH COLUMBIA SAFETY AUTHORITY

Incident Summary (Reference #5616609) (DRAFT) Ammonia release report -witness received trouble alarm the plant exhaust system has been activated. -Chief engineer instructed shift operator to locate leak and isolate compressor at the inlet and outlet valves. -time of alarm 3:37am at 50 parts per million(ppm) in mechanical room -Shift engineer was instructed to switch fan speed to manual high ppm level were between 10ppm with fan on. -received incident report via safety authority. Pictures -Reviewed location of leak on oil separator found minor residue at area of escape.(see picture) -Examined seal ends of seal were painted from factory.(see picture) -installation permit indicates unit was installed March 2016 -pictures of damaged gasket. -Pictures of alarm trends -Picture of manhole cover -Pictures of new gasket Gasket company data sheet. -material is proprietary rubber -compatible with ammonia -gasket failed before recommended service life and replacement. Causes and contributing factors It is likely that over torqueing on the manhole cover against the flanged connection damaged the gasket. Photos or diagrams (if necessary) BRITISH COLUMBIA SAFETY AUTHORITY