MODELS ASHP, ASHH, ASUP, and ASUH

Similar documents
MODELS 304GC, 304GCX, 314GC, and 314GCX

Informer15 Speaker. Description, Specifications, Installation, Operation, and Service Manual. Model I-IP15 IP-Enabled Indoor/Outdoor Speaker

STREAMLINE LP3 INCANDESCENT LIGHTS

MODEL LP3 INSTALLATION AND SERVICE INSTRUCTIONS FOR STREAMLINE LP3 STROBE LIGHTS

ATKINSON DYNAMICS SPEAKERS

INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS FOR Q-SIREN MODELS Q2B-012P, Q2B-012NN, AND Q-MT

Safety Message to Installers of Federal Signal Siren Speakers

Model AS124 Siren Speaker and Mounting Kit Installation Instructions

Model AV1LED Audio-Visual LED Light Installation and Maintenance Manual

Installation Instructions for Q-Siren Q2B-012PSD, Q2B-012NNSD, and Q-MT

Safety Message to Installers of Federal Signal Siren Speakers

Installation and Maintenance Manual. Model 154XST Series Strobe Light for Use in Hazardous Conditions. français...page 21 español...

Safety Message to Installers of Siren Speakers

Electronic Siren System Installation, Maintenance, and Service Manual

Be sure the siren amplifier and speaker(s) in your installation have compatible wattage ratings.

Model IPX-RSW4 Side-Window Mounting Kit Installation Instructions

Pathfinder Amp, PF200AMP, Supplement. Safety Message to Installers of Sound/Light Systems

Installation Instructions for the LatitudeTM Solaris Stick Light Models SL8C-xxx

Model 400 Series Lights Installation Instructions

LED Traffic Clearing Light

Installation Instructions for W2H Series Signals

Model PA300 Series ELECTRONIC SIREN MODELS , , ,

PRICE $4.00 MODEL PA4000 ELECTRONIC SIREN INSTALLATION, OPERATION, AND SERVICE INSTRUCTIONS

Installation Instructions for 2015 F150 Gutter Hook Kits. Safety Message to Installers of Warning Light Equipment. Overview of the Gutter Hook Kits

VSR-M REPLACEMENT Waterflow Switch for Globe Sprinkler Model UMC Manifold

Global Series. Installation and Maintenance Instructions. Model G-STR Strobe Beacon. For Use in Hazardous Locations

Directional Speaker Arrays (DSA)

PRICE $4.00 MODEL PA400SS ELECTRONIC SIREN INSTALLATION AND OPERATION INSTRUCTIONS

Installation & Maintenance Instructions

Vibratone Horns. Models 350 and 450

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR PIPE THREAD IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

Installation and Programming Instructions for the Federal Signal Serial Interface Module

CEILING SPEAKER SYSTEM

Informer100 Speaker Models I-IP100AC and I-IP100DC

MODULATOR SERIES B SPEAKER ARRAYS

CEILING SPEAKER SYSTEMS F-2352CU2

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

Figure 1. Figure 2. See notes 1 and 2 below.

Getting Started Quick Reference Guide

Installation & Maintenance Instructions

FAN POWERED VAV TERMINALS

3CLMR56XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3CLMR56XXD

FMP-MWS. (Discriminating Monitoring Well Sensor BriteSensor ) Installation Instructions

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

FMP-DVS. Monitoring Well Discriminating Vapor Sensor (BriteSensor ) Installation Instructions

INSTRUCTION & SERVICE MANUAL

FMP-DDS & FMP-DTS. Discriminating Dispenser Sump & Turbine Sump BriteSensor. Installation Instructions

LED IMPORTANT SAFETY INSTRUCTIONS

60In. Ceiling Fan. Owner s Manual

Model QuadraFlare. Installation and Service Instructions. Warning Lights

ETSA380MF SHOWN WARNING. shall be used ONLY on approved vehicles. It is the sole responsibility of the user of these devices to ensure compliance.

FMP-DIS & FMP-EIS. Interstitial BriteSensor & Standard Sensor. Installation Instructions

Installation Instructions Remote Blowers

Installation Instructions

PRO Series Energy Star Ceiling Fan Owner's Manual

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

Table of Contents. Part I SAFETY MESSAGE TO INSTALLERS OF EMERGENCY WARNING EQUIPMENT 2 Part II Vehicle Operation 4. Part III Safety Messages 13

Certificate of Compliance

CEILING FAN OWNER'S MANUAL

WATLOW ELECTRIC MFG CO. WATROD Duct Heater (module only) I& M Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.00

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL G1000 AND H1000 SERIES ANNUNCIATORS

INSTALLATION INSTRUCTIONS

High-Velocity Floor Fan

Certificate of Compliance

238 Series. Industrial/Commercial Electric Unit Heater. Owner s Manual

Explosion Proof Line Powered Telephone Ringer

Hazardous Location Supervised Warning Light

WATLOW IND. WATROD Circulation Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

Installation Instructions

AutoTest VSR (VSR-AT) (EU) Vane Type Waterflow Alarm Switch With Electronic Retard and Auto Test Feature

IMPORTANT INSTRUCTIONS

Horizontal/Side Discharge Condensing Units

OPERATORS MANUAL FOR Mi-T-M CORONA DISCHARGE OZONE GENERATORS

BALLAST REPLACEMENT. Contents WARNING INSTALLATION MANUAL

TS-RA1, TS-RA2 and TS-RK Tank Overfill Alarms

MARTIN Insertable Dust Collector

THE COMMISIONER TM 200 WATT ELECTRONIC SIREN & PA SYSTEM Model 4200

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL AH1000, BH1000, AND EH1000 SERIES ANNUNCIATORS

WARNING WARNING. Installation Instructions for 116DEXSTC-FJ AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations.

Code Master Factory Sealed Strobe Luminaires Explosionproof, Dust-Ignitionproof

MN908 No. 282C Replaces 282B LB7013

SWP. (Models SWP08 through SWP20) IMPORTANT! Read before proceeding! OPERATION & MAINTENANCE MANUAL

CAUTION WARNING CAUTION WARNING INSTRUCTION MANUAL 1. SAFETY PRECAUTIONS

WIDE RANGE SPEAKER INSTRUCTION MANUAL TABLE OF CONTENTS

3VNR52/42XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3VNR52XXD / 3VNR42XXD

INSTRUCTION MANUAL TABLE OF CONTENTS

Mounting Kits. LWMB2 6" 6 3 /8" 5 7 /8" 2.6 lbs lbs. LCMB2 6" 5" 5 3 /4 2.3 lbs. 2.5 lbs.

LGB Gas fired boiler

Manual No: Revision: D. Sump Sensor. Installation Guide

CEILING SPEAKER SYSTEM

Print Specification. Publication. Instructions. Specific requirements. General requirements

Caliber Series LED Edgelit Exit Sign EXPORT AC Only or Emergency Operation READ AND FOLLOW ALL SAFETY INSTRUCTIONS

ELECTRONIC FIREPLACE DAMPER

Installation Instructions U-RAD-LT Electric Radiant Heaters

SIGA-CC1 Single Input Signal Module Installation Sheet

CEILING FAN OWNER'S MANUAL

Installation Instructions

CEILING FAN OWNER'S MANUAL

Model SS2000 ELECTRONIC SIREN AND LIGHT CONTROL SYSTEM

READ AND SAVE THESE INSTRUCTIONS

Transcription:

2562229A REV. A 1210 Printed in U.S.A. MODELS ASHP, ASHH, ASUP, and ASUH INSTALLATION AND SERVICE INSTRUCTIONS

blank page

INSTALLATION AND SERVICE INSTRUCTIONS FOR MODELS ASHP, ASHH, ASUP, AND ASUH SAFETY MESSAGE TO INSTALLERS People s lives depend on your safe installation of our products. It is important to read, understand and follow all instructions shipped with these products. Listed below are some other important safety instructions and precautions you should follow: This unit must be installed by a qualified electrician in accordance with NFPA 72, all National and local Electrical and Fire Codes, and be acceptable to the authority having jurisdiction. Do not connect this unit to the system wiring when circuits are energized. For optimum sound distribution do not install this device where objects would block any portion of the front of the speaker. All effective warning speakers produce loud sounds, which in certain circumstances may cause permanent hearing loss. Take appropriate precautions such as wearing hearing protection. Recommendations in OSHA-Sound Level Standard (29 CFR 1910) should not be exceeded. After installation and completion of initial system test, a program for periodic testing of this device must be established. Refer to NFPA 72, local Fire Codes and the authority having jurisdiction for this information. After installation and completion of initial system test, provide a copy of this instruction sheet to all personnel responsible for operation, periodic testing and maintenance of this equipment. Failure to follow all safety precautions and instructions may result in property damage, serious injury, or death to you or others. I. GENERAL. These four models are 24VDC, polarized, high output (with internal volume adjustment), continuous duty, indoor/outdoor rated, audible signaling/amplified speaker devices for use in fire alarm systems. A plug-in tone module is required for tone generation. If the use of externally generated tones or voice signals from a remote amplifier is desired, the plug-in speaker connector cards may be used. See the specification section for compatible plug-in models. Speaker projectors on all models are adjustable and may be repositioned to obtain desired sound distribution. The Models ASHH and ASUH are designed for use in areas where flammable gases, vapors, and liquids and combustible dusts are not normally present, except for abnormal conditions as defined by the National Electrical Code. These models are suit- -1-

able for use in Class I, Division 2, Groups A, B, C, & D; Class II, Division 2, Groups F and G; Class III or non-hazardous locations only. Reference the product nameplate for additional information. II. SPECIFICATIONS. Operating Voltage: Current (depends on tone card or signal used) Models ASHP and ASHH: Models ASUP and ASUH: Weight Models ASHP and ASHH: Models ASUP and ASUH: Regulated 24 Vdc (16 Vdc to 33 Vdc) 0.85 A max. 0.90 A max. 5 lb (2.25 kg) 7 lb (3.2 kg) Construction Amplifier Housing: Die-cast aluminum alloy with powder coated finish. Housing sealed with a neoprene rubber gasket. External mounting bracket on Models ASHH and ASUH. Speaker Cone Tip & Projector: Spun aluminum alloy with powder coated finish. Approval Agency Listings: Reference product nameplate. Compatible Tone Modules: TC-HL, TC-HN, TC-WL, TC-YP, TC-YW, TM2, UTC, or UTM Compatible Speaker Connector Cards: AM25CK*, AM70CK*, CK25*, CK70*, or 300CKS * - Series A versions of these connector cards are not compatible. Audibility Ratings: See Table 1 on page 8. III. INSTALLATION. A. Unpacking. After unpacking the speaker, examine it carefully for possible damage that may have occurred in transit. If equipment has been damaged, immediately file a claim with the carrier stating the extent of the damage. Carefully check all shipping labels and tags for special instructions before removing or destroying them. B. Mounting Arrangements (see figure 1). To maintain the hazardous location rating of the Models ASHH and ASUH, do not use the 7/8" knockout (concealed conduit mounting.) The amplified speaker can be mounted on any relatively flat surface. Conduit connections can be made to the two 1/2" threaded openings at bottom of the housing. A 1/2" conduit plug is supplied for field installation if one of the 1/2" threaded openings is not utilized. After the mounting location and mounting method have been selected, proceed with the applicable instructions below. -2-

Property damage, serious injury, or death could occur if an accumulation of water, snow, dust, etc. resides in the speaker projector, severely reducing or preventing operation of this device. Mount the unit so speaker projector is pointed horizontally or slightly downward. 1. Flat Surface Mounting. a. Remove and retain the two screws that secure cover to housing. Remove the cover. Property damage, serious injury, or death could occur if any objects are in front of the speaker, severely reducing optimum sound distribution. For maximum effectiveness, ensure that the front of the speaker is clear of obstructions. b. Select the mounting location and place rear of the housing against mounting surface. c. Using the mounting holes (two inside for Models ASHP and ASUP s housing or four (4) outside for the Models ASHH and ASUH s external housing bracket) as a template, scribe drill position marks on the mounting surface. See Figure 1 on page 9 for mounting hole locations and dimensions. Before drilling holes in any surface, ensure that both sides of surface are clear of items that could be damaged. d. Secure the unit to a wooden mounting surface with #10 x 1" wood screws. If mounting on a metal surface, drill 13/64 diameter holes and secure the unit with #10 screws, lockwashers and nuts. e. Route wires through the 1/2 threaded openings into the SelecTone unit in accordance with national and local electrical and fire codes. Wire size depends upon the operating current and the distance from the power source. Property damage, serious injury or death could occur if the projector is mishandled during installation or over time. DO NOT rotate the projector more than 180 degrees or internal speaker wiring may be damaged. f. Reposition speaker projector if necessary to obtain desired sound coverage. Loosen collar nut (see Figure 1 on page 9) and move projector to desired position. g. Before reinstalling the housing cover, read paragraph III.C. Electrical Connections below and make the necessary electrical connections. -3-

2. Concealed Conduit Mounting (Models ASHP and ASUP only). a. Remove and retain the two screws that secure cover to housing. Remove the cover. b. Remove the 7/8" knockout at rear of housing. c. Install the conduit connection. d. Route wires through the 1/2" threaded openings into the SelecTone unit in accordance with national and local electrical and fire codes. Wire size depends upon the operating current and the distance from the power source. e. Select the mounting location and place rear of housing against mounting surface. f. Using the two mounting holes as a template, scribe drill position marks on the mounting surface. See Figure 1 on page 9 for mounting hole locations and dimensions. Before drilling holes in any surface, ensure that both sides of surface are clear of items that could be damaged. g. Secure the unit to a wooden mounting surface with #10 x 1" wood screws. If mounting on a metal surface, drill 13/64" diameter holes and secure the unit with #10 screws, lockwashers and nuts. Property damage, serious injury, or death could occur if the projector is mishandled during installation or over time. DO NOT rotate the projector more than 180 degrees or internal speaker wiring may be damaged. h. Reposition speaker projector if necessary to obtain desired sound coverage. Loosen collar nut (see Figure 1 on page 9) and move projector to desired position. Install 1/2 conduit plugs in the unused bottom entry ways (one plug supplied). i. Before reinstalling the housing cover, read paragraph III.C Electrical Connections below and make the necessary electrical connections. C. Electrical Connections. To avoid electrical shock, do not connect wires when circuits are energized. Property damage, serious injury, or death could occur if the housing is not closed properly. To reduce possibility of explosion, the Model ASHH and ASUH s housing cover must be kept tight while circuits are energized. -4-

National Electrical Codes as well as local codes must be adhered to in the installation of these models. All electrical wiring must be routed through approved conduit and fittings as specified. 1. Power Connections. a. Use only 12 to 18 AWG [2.5 mm2 to 1.0 mm2] wire for the power connection. Strip no more than.25 inch [6 mm] of wire insulation from the ends of the power leads. If stranded wire is used, be sure that there are no loose strands outside the connector plug that could touch the adjacent lead and cause a short circuit. b. See Figures 2 and 3. Connect the power source positive (+) lead to one of the (+) terminals of the connector plug. Connect the power source negative ( ) lead to one of the ( ) terminals of the connector plug. Connect the remaining (+) and ( ) terminals on the connector plug to the next unit or an end of line device. circuit board. c. Plug the connector into the receptacle provided on the printed Property damage, serious injury, or death could occur if independent conductors are terminated together, both wires of the same polarity must be used as two separate connections. NFPA 72 requires that the wires be terminated independently to provide electrical supervision of the connection. 2. Tone Card Installation Tone card is purchased separately. NOTE page 10.. a. Plug the desired tone card into the socket as shown in Figure 2 on b. To ensure a proper seal, be sure that the neoprene rubber cover gasket is properly seated in the housing groove and reinstall the housing cover. 3. Speaker Connector Card Installation (Models AM25CK, AM70CK, CK25, and CK70). NOTE Connector card is purchased separately. a. Route the audio signal leads into the enclosure. Connect the input pair of white leads from the connector card to the audio output of the fire alarm panel and the output pair of white leads to the connector card in the next unit or to an appropriate end of line device. Refer to the connector card installation manual provided with the connector card kit for additional wiring information. b. Plug the desired connector card into the socket as shown in Figure 2 on page 10. -5-

c. To ensure a proper seal, be sure that the neoprene rubber cover gasket is properly seated in the housing groove and reinstall the housing cover. NOTE Check with authority having jurisdiction for proper application of EOL resistor and power supervision relay required (see Figure 4 on page 12). Property damage, serious injury, or death could occur if independent conductors are terminated together, both wires of the same polarity must be used as two separate connections. NFPA 72 requires that the wires be terminated independently to provide electrical supervision of the connection, for both the 24VDC speaker power and 25 Vrms or 70 Vrms audio lines. Property damage, serious injury, or death could occur if the housing is not closed properly. To reduce possibility of explosion, the housing cover must be kept tight while circuits are energized. IV. TESTING/OPERATING. Under certain conditions these devices are capable of producing sounds loud enough to cause hearing damage. Adequate hearing protection should be worn if standing within close proximity to device while testing. Recommendations in the OSHA Sound Level Standard (29 CFR 1910F) should not be exceeded. A. After installation is complete, be sure to test the system to verify that each amplified speaker operates satisfactorily. If it is found that the unit is too loud for its location, an internal volume control can be adjusted. Remove the housing cover. Using a slotted screwdriver with an 1/8" blade, gently turn control to desired loudness. See Figure 3 on page 11. Reinstall the housing cover. Property damage, serious injury or death could occur if the housing is not closed properly. To reduce possibility of explosion, housing cover must be kept tight while circuits are energized. B. After completion of initial system test, establish a program for periodic testing of this device. Refer to NFPA 72, local Fire Codes and the authority having jurisdiction for this information. C. Provide a copy of these instructions for the Safety Engineer, system operator(s) and maintenance personnel. -6-

SAFETY MESSAGE TO OPERATORS Even if your warning system is operating properly, it may not be completely effective. People may not hear or heed your warning signal. You must recognize this fact and ensure that your warning signal achieves its intended effect through proper test/training sequences within your specific application(s). V. MAINTENANCE. SAFETY MESSAGE TO MAINTENANCE PERSONNEL Failure to follow all safety precautions and instructions may result in property damage, serious injury, or death to you or others. Read and understand all instructions before performing maintenance on this unit. To reduce the risk of electrical shock or ignition of hazardous atmospheres, do not perform maintenance or service on this unit when circuits are energized. Periodic checks should be made to ensure that effectiveness of this device has not been reduced because speaker has become clogged with a foreign substance or because objects have been placed in front of the speaker. Any maintenance to this unit MUST be performed by a trained electrician in accordance with NEC guidelines and local codes. Never alter this unit in any manner. Safety in hazardous locations may be jeopardized if additional openings or alterations are made to Models ASHH or ASUH. The nameplates, which contain cautionary or other information of importance to maintenance personnel, should not be obscured if exterior of device is painted. A. Periodically check this device to verify that there are no foreign substances in, or in front of the speaker, which will reduce its effectiveness. B. Testing should be periodically performed. Refer to NFPA 72G, local Fire Codes and the authority having jurisdiction for information. C. In the event a volume adjustment or other repair is required, be sure to refer to the Safety Message For Maintenance Personnel before proceeding. Unauthorized repair/servicing of the unit may result in degradation of performance and/or property damage, serious injury, or death to you or others. If a malfunctioning unit is encountered, do not attempt any field repair/retrofit of parts. -7-

- EXPLOSION HAZARD Substitution of components may impair suitability for Class I, Division 2 and Class I, Zone 2. VI. SERVICE. Federal Signal will service your equipment or provide technical assistance with any problems that cannot be handled locally. Any units returned to Federal Signal for service, inspection, or repair, must be accompanied by a Return Material Authorization. This R.M.A. can be obtained from the local Distributor or Manufacturer s Representative. At this time a brief explanation of the service requested or the nature of the malfunction, should be provided. Address all communications and shipments to: FEDERAL SIGNAL CORPORATION Industrial Products Division Service Department 2645 Federal Signal Drive University Park, IL 60466-3195 Table 1. Tone and Connector Card UL Audibility Ratings. RATING UL db (A) SOUND PRESSURE PER UL1480 Model ASHP and ASHH Model ASUP and ASUH Tone Card* 95 100 AM25CK, CK25 101 103 AM70CK, CK70 101 103 * Based on TM6, Horn -8-

1 290A5618 A" C" B" COLLAR NUT 2-3/4" (70) 1-13/16".201" (5) DIA. 2 HOLES (46) (MOUNTING) 2-9/16" (65) 1/2-14 NPT 7/8" (22) DIA. CONCEALED CONDUIT KNOCK OUT MOUNTING(IN REAR OF HOUSING) 13/16" (21) 3-3/8" (86) A B C MODELS ASHP & ASUP MODELS ASHH & ASUH 5-5/8" (143) 3-1/4" (83) MODELS MODELS ASHP & ASHH ASUP & ASUH INCHES MM INCHES MM 8-1/8" 12-5/8" 8-1/4" 206 320 206 10" 15" 11" 254 381 279 1/2" CONDUIT PLUG SUPPLIED 5-5/8" (143) 2-1/4" (57) in (mm) A" C" B" COLLAR NUT 5" (127) 5-1/2" (140).201" (5) DIA. 4 HOLES (MOUNTING) 1/2-14 NPT 13/16" (21) 3-3/8" (86) -9-

2 L + L + Ṉ Ṉ L L Ṉ Ṉ + + -BLK +RED 24VDC POWER +RED -BLK +RED -BLK END OF LINE DEVICE RECOMMENDED BY CONTROL UNIT SUPPLIER 290A5619-10-

3 VOLUME CONTROL TONE/CONNECTOR CARD SOCKET + POWER CONNECTOR PLUG L+ L+ N- N- L+ L+ N- N- EARTH GROUNDING TERMINAL 290A5620-11-

4 INTERNALCONNECTOR CARD (25 OR 70VRMS SUPPLIED SEPARATELY) L + L + N _ N _ L + L + N _ N _ END OF LINE DEVICE RECOMMENDED BY CONTROL UNIT SUPPLIER SPEAKER POWER 25, OR 70 VRMS AUDIO + _ WHT WHT WHT WHT WHT WHT _ + FOR 24 VDC USE: POWER SUPERVISION RELAY MODEL A77-716-02 BY SYSTEM SENSOR, OR MODEL R64 BY UNITED SECURITY PRODUCTS 290A5621-12-

blank page

2645 Federal Signal Drive, University Park, IL 60484-3167 Tel.: (800) 264-3578 Fax: (800) 682-8022 federalsignal-indust.com 2010 Federal Signal Corporation