GE Monogram. Installation. Instructions. Professional Ranges. 48" Natural Gas Models ZDP48N4GWSS ZDP48N6RWSS ZDP48N6DWSS

Similar documents
GE Monogram. Installation. Instructions. Professional Ranges. 48" Natural Gas Models ZDP48N4G ZDP48N6R ZDP48N6D

GE Monogram. Installation. Instructions. Professional Gas Cooktops 48" Natural Gas Models ZGU48N4GWSS ZGU48N6RWSS ZGU48N6DWSS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

GE Monogram. Installation. Instructions. Component Cooktop System. Models ZEW145V ZGW124EN3 ZGW125EN3 ZEW155N ZEW166Y ZEW176Y

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Installation Instructions If you have questions, call 800-GE-CARES or visit our website at:

PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.

INSTALLATION INSTRUCTIONS FOR FREESTANDING DUAL FUEL

Installation Instructions

Installation Instructions

Advantium TM. Built-In. Speedcook Ovens. Installation. Instructions

Installation Instructions

Installation Instructions Dual Fuel Ranges

GAS COOKTOP INSTALLATION INSTRUCTIONS

30" GAS RANGE INSTALLATION INSTRUCTIONS (For Models with Sealed Top Burners)

GE Monogram. Installation. Instructions. Stainless Steel Bottom Mount Built-In Refrigerators. Models ZICS36N RH ZICS36N LH

Installation Instructions

INSTALLATION INSTRUCTIONS

Installation Instructions

2 PREPARE THE OPENING

Installation Instructions 30 French Door Built-in Wall Ovens

Installation Instructions

Installation Instructions

GAS COOKTOP INSTALLATION INSTRUCTIONS BEFORE YOU BEGIN. IMPORTANT Save these instructions for local electrical inspector s use.

INSTALLATION GUIDE Dual Fuel Ranges

Installation Instructions

Built-In Dishwasher. Installation Instructions. BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT The dishwasher MUST be

Multi-Function Cooktop

Viking Installation Guide

DESIGN CLASS FUNCTION

GE Monogram. Automatic. Icemaker. Installation Instructions. Models ZDI15 ZDIS15. monogram.com

Installation Instructions If you have questions, call 800.GE.CARES or visit our website at:

IMPORTANT SAFETY INSTRUCTIONS

0= Professional48",36", 30" _ JENN-AIR Gas RangeModels,03WEST,OO,T. ST EE,,,ORT...E_O. Retain this manual for future reference.

A PROUD HERITAGE OF EXPERIENCE & QUALITY DISHWASHER BR- DWSH01- S

Installation Instructions for Models: HES232U, HES236UHES246U, HES247U, HES245U, HES242U, HES256U, HES255U, HES252U

INSTALLER: LEAVE THESE INSTRUCTIONS WITH THE APPLIANCE INSTALLATION MANUAL. 'Gas 30-inch Wide Free-standingRange

Installation Instructions

V SERIES HDR GAS RANGES

Installation Instructions

INSTALLATION INSTRUCTIONS

Installation Instructions

Installation. Built-in Full Height Wine Cellar VCWB301

Installation Instructions

Installation Instructions Built-In Dishwasher

INSTALLATION INSTRUCTIONS MANUAL STEEL GAS STAR COOKTOPS 30" MODELS: SGS304, SGSX304 36" MODELS: SGS365, SGSX365 45" MODELS: SGS456, SGSX456

Installation Instructions

Installation Instructions

Downdraft Ventilation

DESIGN CLASS FUNCTION

Dishwasher Installation Instructions DW 24XT/DW 24XV

Microwave Oven. IMPORTANT SAFETY INSTRUCTION Never operate the oven when it is empty or without the glass turntable.

GAS COOKTOP MODELS: CTG365D, CTG305D, CTG304D TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING

Questions on Installation? Call: GECARES (US) or Visit our Web site at: (US) 4" DUCT CLAMPS (2) OR 4" SPRING CLAMPS (2)

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Viking Installation Guide

D UAL F UEL R ANGES INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Installation Instructions Built-In Dishwasher

Viking Installation Guide

For use with models: PGM304-1, versions M-B PGM365-1, versions M-E, M-F & M-G

A PROUD HERITAGE OF EXPERIENCE & QUALITY DISHWASHER BR-DWSH01-S

Installation Instructions

30" ELECTRIC SLIDE-IN RANGE INSTALLATION INSTRUCTIONS

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

Installation Guide. 15 W./24 W. Undercounter Refrigeration

Installation Instructions. Parts Included. Materials Needed. Tools You Will Need. 30 Sealed Gas Cooktop

Installation Instructions

Gas Cooktop Installation, User and Service Instructions GMS 955.1

Installation Instructions Built-In Dishwasher

SAFE DRINKING WATER AND TOXIC ENFORCEMENT ACT

Installation Guide. 15 W./24 W. Undercounter Refrigeration U L. Viking Range Corporation. 111 Front Street. Greenwood, Mississippi USA

Installation Instructions

Installation. 3 Series Freestanding 30 Dual Fuel Self-Clean Sealed Burner Range

INSTALLATION INSTRUCTIONS

Installation. Professional Freestanding Dual Fuel Ranges VDSC530 / VDSC536 / VDSC548 / VDSC560 CVDSC530 / CVDSC536 / CVDSC548

Installation. Freestanding 30 Gas Self-Clean Sealed Burner Range

Installation Instructions

INSTALLATION INSTRUCTIONS

Installation Instructions

Viking Installation Guide

INSTALLER: LEAVE THESE INSTRUCTIONS WITH THE APPLIANCE INSTALLATION MANUAL. Dual Fuel 30-inch Wide Free-StandingRange

INSTALLATION MANUAL. Rangetops. RNB Heritage Classic Platinum

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

Installation Instructions

Dryer. User manual DV22K6800** DV22K A-00_EN (US)_ indd :15:41

PCG305P 30-INCH GAS RANGETOP PROFESSIONAL SERIES, PORCELAIN COOKTOP SURFACE

Installation Instructions

Viking Installation Guide

INSTALLATION INSTRUCTIONS ELECTRIC DRYER

Viking Installation Guide

Ilnstallat!on. nstruct=ons. Before You Begin. Parts Included. Tools Needed. Built-In Wall Oven with Microwave ATTENTION INSTALLER

Installation Instructions

Transcription:

GE Monogram Installation Instructions Professional Ranges 48" Natural Gas Models ZDP48N4GWSS ZDP48N6RWSS ZDP48N6DWSS 48" LP Gas Models ZDP48L4GWSS ZDP48L6RWSS ZDP48L6DWSS 36" Natural Gas Models ZDP36N6WSS ZDP36N4RWSS ZDP36N4DWSS 36" LP Gas Models ZDP36L6WSS ZDP36L4RWSS ZDP36L4DWSS 30" Natural Gas Model ZDP30N4YSS 30" LP Gas Model ZDP30L4YSS

CAUTION WARNING Before you begin Read these instructions completely and carefully. IMPORTANT: Save these instructions for local inspector s use. IMPORTANT: OBSERVE ALL GOVERNING CODES AND ORDINANCES. NOTE TO INSTALLER: Be sure to leave these instructions with the Consumer. NOTE TO CONSUMER: Keep these instructions with your Use and Care Book for future reference. This appliance must be properly grounded. See Electric Supply, page 7. If you have questions concerning the installation of this product, call the GE Answer Center Consumer Information Service at 800.626.2000, 24 hours a day, 7 days a week. If you received a damaged range, you should contact your dealer. Installation of this range requires basic electrical, carpentry and mechanical skills. Proper installation is the responsibility of the installer. Product failure due to improper installation is not covered under the GE Appliance Warranty. See the back cover of the Use & Care Guide for warranty information. CAUTION: THESE RANGES MUST BE INSTALLED IN CONJUNCTION WITH A SUITABLE OVER- HEAD VENT HOOD. Due to the high heat capacity of this unit, particular attention should be paid to the hood and duct work installation to assure it meets local building codes. Standard installations: 48" Ranges require a hood with 1200 CFM blower. 30" and 36" Ranges require a hood with 600 CFM blower. Hoods should be 24" min. deep and the same width as the cooktop. Island installations: 48" Ranges require a hood with 1200 CFM blower. 36" Ranges require hood with 600 CFM blower. Hoods should be 30" min. deep and 36" wide at the bottom. Check local building codes for the proper method of gas range installation. Local codes vary. Installation, electrical connections and grounding must comply with applicable codes. In the absence of local codes, the gas range should be installed in accordance with the National Fuel Gas Code ANSI 223.1, latest edition and National Electrical Code ANSI/ NFPA 70, latest edition. CAUTION: These ranges weigh up to 600 pounds. Some disassembly will reduce the weight considerably. Due to the weight and size of the range and to reduce the risk of personal injury or damage to the product, TWO PEOPLE ARE REQUIRED FOR PROPER INSTALLATION. Contents Design Information Models Available... 3 Accessory Requirements... 3 Models Dimensions and Clearances... 4,5 Advance Planning... 6 Tools & Materials Required... 6 Installation Preparation Power Supply Locations... 7 Installation 1: Remove Packaging... 8 2: Level the Range... 9 3: Install Anti-Tip Device... 9 4: Connect Range to Gas... 11 5: Install the Range Backguard... 11 6: Connect Electrical... 12 7: Slide Range Into Position... 12 8: Replace Oven Doors... 12 9: Assemble & Adjust Burners... 13 10: Adjustable Low Burner Settings... 13 Finalize Installation... 13 2

Design Information Models Available These ranges are factory set for either natural gas or liquid propane gas. Order the model for your installation situation. 48" Natural Gas Models: ZDP48N4GWSS 4 gas burners, grill and griddle ZDP48N6RWSS 6 gas burners and grill ZDP48N6DWSS 6 gas burners and griddle 48" Liquid Propane Gas Models: ZDP48L4GWSS 4 gas burners, grill and griddle ZDP48L6RWSS 6 gas burners and grill ZDP48L6DWSS 6 gas burners and griddle 36" Natural Gas Models: ZDP36N6WSS 6 gas burners ZDP36N4RWSS 4 gas burners and grill ZDP36N4DWSS 4 gas burners and griddle 36" Liquid Propane Gas Models: ZDP36L6WSS 6 gas burners, grill and griddle ZDP36L4RWSS 4 gas burners and grill ZDP36L4DWSS 4 gas burners and griddle 30" Natural Gas Model: ZDP30N4YSS 30" Liquid Propane Gas Model: ZDP30L4YSS Accessory Requirements All models require the installation of a backguard. A backguard should be ordered at the same time as the range. Both must be on site at the time of installation. Order one backguard for 48" Models: ZX1B48WSS 1-1/2" high backguard (required for island installations or installations with non-combustible wall behind range) ZX12B48WSS high backguard ZX22B48WSS 22" high backguard with warming rack Order one backguard for 36" Models: ZX1B36WSS 1-1/2" high backguard for island installations or installations with non-combustible wall behind range ZX12B36WSS high backguard ZX22B36WSS 22" high backguard with warming rack Order one backguard for 30" Models: ZX1B30YSS 1-1/2" high backguard for island installations or installations with non-combustible wall behind range ZX12B30YSS high backguard ZX22B30YSS 22" high backguard with warming rack 22" High Backguard With Warming Shelf High Backguard 1-1/2" Backguard for Island Installations only 3

Design Information Product Dimensions & Clearances Optional Backguards 21-1/4" 1-1/2" Optional Backguards 21-1/4" 1-1/2" 35-1/4"-36-3/4" 35-1/4"-36-3/4" 28-1/4" 47-7/8" 28-1/4" 35-7/8" 48" Wide Range Models 36" Wide Range Models 3-1/4" 29-1/16" 21-1/4" High Shelf Low Back 36" Min. to Combustibles 1-1/2" Min. to Combustibles Without Backguard Island Trim 36" Min. to Combustibles 0" Clearance 0" Clearance 28-1/4" 31-1/2" All Models 45-5/8" 48" and 36" Range Models 4

Design Information Product Dimensions & Clearances Optional Backguards 21-1/4" 1-1/2" 21-1/4" 3-1/4" 27-3/8" High Shelf 36" Min. to Combustibles Low Back 35-1/4"-36-3/4" 0" Clearance 26-3/4" 29-7/8" 30" Wide Range Models 26-3/4" 29-1/4" 43-7/8" 30" Wide Range Hood Or 36" Wide Range Hood Or 48" Wide Range Hood 18" Min. 30"/36" Wide Models 4" 48" Wide Models 8" 30"/36" Wide Models 4" 48" Wide Models 8" 30"/36" Wide Models 48" Wide Models 16" 13" Max. Min. to Combustible Material Each Side 36" Min. to Combustible Material From Cooking Surface Cooking Surface 3-1/4" 3-1/2" Gas Supply Electrical Supply 35-3/8" Max. for Counter Level 36-3/4" Max. with Range Leveling Legs Fully Extended 5

Design Information Advance Planning Refer to Dimensions and Clearances for appropriate placement and necessary clearances when planning the installation. Cabinetry can not be installed directly above the range. These ranges requires the installation of a vent hood, 30" to 36" above the surface. The vent hood must be at least 24" deep. The vent hood must be the same width as the range. For 48" models, the vent hood blower must provide 1200 CFM. For 30" and 36" models, the vent hood blower must provide 600 CFM. Working areas adjacent to the range should have 18" minimum clearance between countertop and cabinet bottom. Clearance between range and side wall or combustible material must be at least on each side. If the range is installed in an island: Allow min. clearance at the back to combustible materials. Allow 36" min. above the cooking surface to combustible materials. For 48" models, the vent hood blower must provide 1200 CFM. For 30" and 36" models, the vent hood must provide 600 CFM. Installation must conform with local codes. In the absence of local codes, the range must comply with the National Fuel Gas Code, ANSI Z223.1, latest edition. A.G.A. approved. Tools & Materials Required: Saw Measuring tape Carpenter s square Pipe and fittings as required. Manual gas line shut-off valve. Gas pressure regulator (supplied) Large flat-blade screwdriver Pipe wrench Drill and appropriate bits Safety glasses Gas-resistant pipe joint sealant 5 foot, 5/8" AGA-certified flexible metal gas supply line. If required by local codes, use solid pipe fittings. Note: Purchase new flexible line. DO NOT USE OLD, PREVIOUSLY USED FLEXIBLE LINE. 6

Installation Preparation Power Supply Locations Gas Supply: The natural gas models are designed to operate at 6" to 14" water column pressure. The liquid propane models are designed to operate at 11 to 14" water column pressure. A regulator is required at the L.P. source to provide a maximum of 14" water pressure to the range regulator. These gas ranges are supplied with 1/2" NPT female gas connection located at the left rear corner. A minimum 5/8" dia. metal flexible line is required. For flexible connection, locate pipe stub on the back wall as illustrated. Use 5-foot, 5/8" long flexible gas supply line. For rigid connection, locate the pipe stub as illustrated. Install a manual shut-off valve in the gas line, in an easily accessible location. Electric Supply: These ranges must be supplied with 208/240 volt, 60 Hz., and connected to a individual, properly grounded branch circuit protected by a 50amp circuit breaker or time delay fuse. The receptacle must be a NEMA 14-50R devise to accept the 4-prong plug supplied with the range. 4" For 30"/36" Models 8" For 48" Models Gas Supply Flex Line to Range 2" Maximum Protrusion From Wall For Gas Supply For 30"/36" Models 16" For 48" Models Electrical Supply NEMA 14-50R Receptacle 3-1/4" 3-1/2" If the electrical service provided does not meet the above specifications, it is recommended that a licensed electrician install an approved outlet. Locate the electric supply as illustrated. CAUTION WARNING The range is equipped for use with an electrical supply which uses a separate grounding conductor (4 wire system). If this range must be connected to an electrical system which utilizes a single conductor for ground and neutral (3 wire system), the grounding jumper at the terminal block must be connected. The grounding jumper is located behind the front kick panel. Green Connect Here Red Terminal Block White Black To connect grounding jumper: Disconnect restraining clip holding jumper. Connect green jumper to open terminal on neutral (white) portion of the terminal block. 7

Installation 1 Remove Packaging Before moving the range indoors: Remove outer carton and packing material from the shipping base. Door Hinge Roller Lock (Closed) Un-Lock Kick Panel Remove the kick panel by removing 2 screws at the top and pulling forward. Remove oven doors: Open the door fully and hold down. Close the brass hinge latches to locked position on each side. Carefully, lift and pull the door away from the range and out of the frame. Left Rear Shipping Screws Range Must be Uniformly Supported on Braces 22" Leveling Legs The range is secured to the skid with 2 bolts in the front and 2 L brackets on the bottom flange of the range back. Remove bolts and L brackets. Due to the weight of these ranges, use a dolly with soft wheels to move this range. Lift the range onto the dolly and move indoors. To simplify handling and to reduce the weight of the range: Remove the grates and drawers below the knobs. Remove grill and griddle covers. DO NOT ATTEMPT TO REMOVE A GRILL OR GRIDDLE ASSEMBLY. Remove the broiler pans/literature package from inside oven(s). 8

Installation 1 Remove Packaging (continued) 36" and 48" Wide Models: Remove the panel from the rear of the shipping pack. Lay the panel on the floor directly in front of the installation location. The range should be placed on this panel to prevent damage to the floor. All Models: Remove the two strips from the oven interior. Place the strips on the floor at the left and right sides of the installation location. These strips provide a surface for sliding the range into the final position and will prevent damage to the floor. The leveling legs must rest permanently on these runner strips. Range Opening Runners To Support Leveling Legs Panel 2 Level the Range 3 Install Anti-Tip Device Note: Rear range leveling legs are not accessible after installation. Check to be sure the adjoining cabinets/ countertops are level, front to back and left to right across the opening of the range. Measure the distance from the floor to the top of the countertop in the left and right rear corners. CAUTION WARNING All Ranges Can Tip Injury Could Result Install Anti-Tip Bracket Provided Adjust the height of the range to countertop height or higher. IMPORTANT: The range should always be installed at countertop height or higher. DO NOT INSTALL THE RANGE LOWER THAN ADJACENT COUNTERTOP HEIGHT. All Ranges must have an anti-tip device correctly installed according to these instructions. If the range is pulled out from the wall for any reason, make sure that the device is properly engaged when pushed back against the wall or installation position. If the anti-tip device is not engaged, there is a possible risk that the range can tip over and cause injury if you or a child stand, sit or lean on an open door. See Instructions [4] #10 x 2" wood screws The anti-tip bracket is designed to be installed on top of the slide (runners) provided with the range. Any other type of construction may require special installation techniques to insure adequate fastening of the anti-tip bracket to the floor or wall. The bracket must be properly installed to prevent tipping of the range. Read the AHAM Anti-Tip Safety brochure packed with the product. AHAM Anti-Tip Safety Brochure Anti-Tip Bracket 9

Installation 3 Install Anti-Tip Device (continued) Small Holes For Wood Installations (2 Total) Wood Slide Strip Small Hole For Wood Installations (2 Total) (2) Large Holes For Concrete Installations Right Side Of Wall or Range (2) Wood Screws into Back Wall (All Installations) Back Wall Dimension A Dimension A A= 1/2" 5/8" 1/4" Models ZDP48 ZDP36 ZDP30 Wood Construction: Place the bracket against the back wall, into the right rear corner of the installation location. See Dimension A, position the bracket the correct distance from the right side. Mark the 2 small screw holes for fastening the bracket to the floor and remove the bracket. Drill two, 1/8" diameter pilot holes. Fasten the bracket securely to the floor and wall using all 4 screws provided. Concrete or Cement Construction: Hardware Required (not supplied): [2] sleeve anchors, lag bolts and washers. Place the bracket against the back wall, into the right rear corner of the installation location. See Dimension A, position the bracket the correct distance from the right side. Mark the 2 large holes for fastening the bracket to the floor and remove the bracket. Drill recommended size holes for the hardware. Install the sleeve anchors into the holes and then install the lag bolts through the bracket. The bolts must be properly tightened as recommended for the hardware. Fasten the bracket securely to the floor. Drive wood screws into the back wall. 10

Installation 4 Connect Range to Gas A manual shut-off valve must be installed where it will be accessible from the front. Assure that gas is turned off at the shut-off valve. Remove all burner/hanger screws. Lift and remove all open top burners/hangers to reveal the gas inlet location at the back of the range. Pull the flexible metal gas line through the back of the range and into the cooking area until it meets the regular. Connect flexible metal connector to incoming gas line pipe stub. Turn on gas and check for leaks: Use a liquid leak detector at all joints and connections in the system. Flex or Rigid Gas Line To Regulator Flex or Rigid Gas Line To Regulator Regulator 36" Models Regulator 48" Models 30" Wide Models: Rigid pipe is factory installed from the regulator to the bottom rear of the range. Flexible line may be used to connect to the pipe stub. Factory Installed Rigid Gas Line 5 Install the Range Backguard A backguard is required for all installations. Insert the backguard into the guide channels on the back of the range. Secure the backguard to the range at the rear with the 4 sheetmetal screws provided. Install 2 or 3 screws through the front of the range, depending on your model. Regulator 30" Models 11

Installation 6 Connect Electrical Plug power cord into properly grounded receptacle. 7 Slide the Range Into Position Carefully, slide the range into position. Be careful not to entange power cord and gas flexible tubing. Be sure the right rear leg is engaged in the slot of the installed anti-tip bracket. Check for proper installation by grasping the range at the top front edge and carefully attempt to tilt the range forward. Check to be sure the front of the range is level. Adjust front leveling legs accordingly. Replace the front kick panel by reversing the proceedure described in 1. 8 Replace Oven Door(s) To replace the oven doors: Slide the hinges into the openings. The hinge should rest in the center of each hinge roller. Open the door fully and unlock hinge latches. CAUTION: Take care when replacing the oven doors. If the hinge latch is not securely locked, the hinge may snap back and separate. If the hinge separates, you must apply pressure (possibly with your foot) to press it back together and then engage the brass hinge latch. Door Hinge Roller Lock (Closed) Un-Lock 12

Installation 9 Assemble & Adjust Burners Replace the burner bowls and burner caps. Adjustments should not be required, unless vibration during transit or variations in local gas supply make minor adjustments necessary. CAUTION: Burner adjustments must be made by a qualified technician at the time of installation. Extreme care should be used if adjustments are made after installation. Burner flames should be blue and stable with no yellow or yellow tips, excessive noise or lifting of the flame from the burner. If any of these conditions exist, check that the air shutter or burner ports are not blocked. If one of these conditions continues, adjust the air shutter as required. If the flame is too yellow, there is insufficient air flow, adjust the shutter counterclockwise to increase air inlet. If the flame is noisy or tends to lift away from the burner, there is too much air. Turn the shutter clockwise to reduce air. Burner Igniter Burner Main Burner Venturi (rear) Igniter Main Burner Venturi (rear) Simmer Burner Venturi (rear) Air Shutter Simmer Burner Venturi (rear) 10 Adjustable Low Setting The open top burners and grill valves have an adjustable low setting. Each valve is individually tested and adjusted before it is shipped. Minor adjustments may be required due to fluctuations in local gas pressure. Adjustments to increase or decrease gas flow may be necessary. Turn knob counter-clockwise to the LITE position. Once lit, turn the know back to the LOW position. Remove the knob. Insert a thin-blade flat screwdriver into the valve shaft. (3/32" blade with recommended.) Grip the shaft with pliers and turn the screwdriver counter-clockwise to lower the flame, or clockwise to increase the flame. CAUTION: Do not turn the flame so low that it goes out, causing the igniter to spark. When the desired setting is made, replace the knob and turn burner off. Finalize Installation Place the burner grates into operating position. Press corner of the grate to the cooktop. The grates should be seated and should not rock. Models equipped with grill and griddle: The grill and griddle are secured with screws at the front. They are designed to be stationary and should not to be removed. The griddle has two leveling screws beneath the rear flue cover which can be used to adjust to the desired slope. The center screw is for shipping purposes only and should be removed. 13

Notes 14

Notes 15

NOTE: While performing installations described in this book, safety glasses or goggles should be worn. To obtain specific information concerning any Monogram product or service, call GE Answer Center consumer information service at 800.626.2000 any time, day or night. For Monogram local service in your area, call 1-800-444-1845. Monogram. General Electric Company Louisville, KY 40225 NOTE: Product improvement is a continuing endeavor at General Electric. Therefore, materials, appearance and specifications are subject to change without notice. Pub. No. 49-8814 Dwg. No. 164D3333P058 1997 GE Appliances (N.D. 719) 9/97 10658 Rev. 2