U-CLASS SPA SYSTEMS. Dealer TechBook by Gecko Alliance. Technical Specifications, Programming, Installation & User's Instructions!

Similar documents
TechBook. in.k300tm. Bright LCD screen Spa function icons Affordable. the essential spa keypad

DistributedBy. 7215BermudaRoadLasVegas,NV89119 TolFree: Fax:

CLEARLY ADVANCED SPA SYSTEMS! OWNER'S MANUAL MC-MP-SBD SPA SYSTEMS INSTALLATION, INSTRUCTIONS & MORE! TAKING OVER THE WAVES!

MSPA-MP METAPACK SERVICE MANUAL. Visual step-by-step guide to easily identify & correct technical problems! Gecko Electronics Inc.

HT-2 / 9600 Series Control Contents

Spa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert)

TOUCHSTONE Dual Variable Speed System. Installation & Operating Manual with Troubleshooting and Configuration Guide

Spa Touch Control Panel with 2000, 2100 controllers. (Spa Owner s Manual insert)

TechBook. in.xetm innovative spa pack platform. Versatile Easy to install Watertight

Table of contents. in.k200 keypad overview - introduction function description instructions Typical settings...

FH3HT. 3Kw HIGH TEMPERATURE ELECTRIC FAN HEATER PRODUCT MANUAL

NR-20DU. Keep this manual near this remote controller for future reference whenever maintenance or service is required.

Check that connection to main board is clean and sound at J8

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

spatouch Menued Control Panels

Table of contents. in.k200 keypad overview - introduction function description instructions Typical settings...

SERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS

USER S MANUAL HSC-14/18/24/24A

DRAFT INSTALLATION INSTRUCTIONS. Solid-State Series !! NOTE!! Covers the following models: Refer to INSERT for additional information

6500/7500 SERIES OWNERS OPERATION GUIDE

SERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

THE BEAUTY OF WATER THE SCIENCE OF RENEWAL. Heating Circulation System. Installation Instruction Manual

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

Installation and user manual

21D83M-843 Integrated Single Stage Furnace Control Replacement Kit INSTALLATION INSTRUCTIONS

Synergy3 Owner s Manual. Owner s Manual. Geothermal Heating Cooling Hot Water

Table of contents. in.k200 keypad overview - introduction function description instructions Typical settings...

CONTENTS CONSIDERATIONS. General Plumbing Component Connection ILLUSTRATION. Control System CONFIGURATION. Voltage Verification CONNECTION

4230/6230/9230 SERIES OWNERS OPERATION GUIDE

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack

DDAC-1 deluxe digital atmosphere controller

INTELLILEVEL AUTOMATIC WATER LEVELING SYSTEM FOR POOL AND SPA

F Operating Manual. ESS0460-H119 PV Module Solar Soaking Chamber

Heater-Controller Package manual

DIMENS. MIN TYPICAL MAX A 71.0 (2.795) 71.0 (2.795) 71.8 (2.826) B 29.0 (1.141) 29.0 (1.141) 29.8 (1.173)

RC300 IntelliFire Plus Multifunction Remote Control Installation & Operating Instructions

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

INSTALLATION AND OPERATION INSTRUCTIONS

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

Dixell Installing and Operating Instructions release 7.0

CA5000 Liquid CO 2 Freezer Backup System

Portable Refrigerator

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

CONTROLS INSTRUCTIONS MANUAL ENGLISH

Optional Optional. Min 20W, max 100W. Only resistive load or dimmable (phase control compatible) light bulb. Dimmer optional

SSV-DC user manual. Phason

4100/6100/7100 SERIES OWNERS OPERATION GUIDE

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL

IMR 5000 IMR 400. CEMS Operating Manual IMR USA S/N: Sample IMR Sensors Inside IMR 400. Gas Dryer Inside. IMR Environmental Equipment Inc.

INSTANT-FLOW C-MICRO WATER HEATER

Equipment Booklet. Sousou SPA. for

M770 ph Controller Owner s Manual

Settings and Maintenance of the CombinAir

4200/6200/9200 SERIES OWNERS OPERATION GUIDE

108A OTP1800. Grid Support. General Description

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL FOR

I/O ZONE 560/583 AND OPERATION MANUAL

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

intelligent solutions

AIRREX DEHUMIDIFIER ADH-100 USER S MANUAL

MR3CCUHV Temperature/Defrost Control

Model Universal Oil Primary Control

DISHWASHER INSTALLATION GUIDE SPECIFICATIONS, INSTALLATION, AND MORE

EGE Manisa 70 cm BIR Carinaro 55 cm. Fabriano June Presenter Francesco Nieli

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table)

Spas with 2 or 3 Pumps

Smart Temp. Model

Peak Partners Web-Programmable Thermostat Homeowner s Manual. Look inside for a complete guide to the setup and operation of your new thermostat.

Inspect bath carefully and report any damage or faults before installation. No claims can be entered in to after installation.

MS4PMUHVT Multi-Stage Electronic Temperature Control with Relay Pack

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

INSTANT-FLOW C-MICRO WATER HEATER

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

SERVICE-MANUAL INDUCTION COOKER BASE-LINE/FAJITA HEATER SH/BA 3500 FH

II SL. Installation Guide. VOLTEX IMS64-2 Dual output indoor flush mount PIR motion detector IMS64-2

5) Do not start or stop the unit by inserting or pulling out the power plug.

Janfire Pellet Burner Boiler. for single / double burner management (Version 1.1)

Please read this manual before proceeding with installation.

Introduction. Information on Your Spa

INSTALLATION INSTRUCTIONS FOR SERIES 9 INTERMITTENT PILOT IGNITION CONTROL

DIGITAL LIGHT CONTROLLER

Model 6495 Freezing Rain Sensor. User's Manual. All Weather Inc National Drive Sacramento, CA USA

TABLE 1. Specifications: Dimensions: 6¼ x 9 5/8 x 2 ¾

4230/6230/9230 SERIES OWNERS OPERATION GUIDE

Operator: Save these instructions for future use!

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

spatouch Icon Driven Control Panels

SAT- 3 Installation Setup Guide

2017 Spa Touch Control Panel with 2000, 2100, 501, 6013 controllers (Spa Owner s Manual insert)

4200/6200/9200 SERIES

Warming Drawer Installation Guide

VADA - Rain2Main Automatic Rainwater Controller

Refrigerated air dryers

INSTALLATION AND OPERATION INSTRUCTIONS FOR WALL-MOUNT AND BUILT-IN UNITS

Marco Beverage Systems Ltd.

OWNERS OPERATION GUIDE

PARTS AND SERVICE MANUAL FOR MERCO HOLDING CABINET MODEL 86002

EXPERT TRI-STAR. Temperature controller. User s Manual

MODEL A18 SOLVENT RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

Transcription:

U-CLASS SPA SYSTEMS Dealer TechBook by Gecko Alliance Technical Specifications, Programming, Installation & User's Instructions!

UC-CF TABLE OF CONTENTS Specifications 2 Description System features Electrical specifications Environmental conditions Installation & Interconnections 3 Power unit Power input Keypad Pump Light Dry-fire probe Ozonator Keypad 4 Installation procedure Instructions 5 Pump key Light key Up & Down arrow keys Automatic water heater start Instructions & Options 6 Filter cycle Water temperature display Additional features Other Features 7 Smart Winter Mode High limit temperature Overtemp mode protection Water level sensor Temperature probe

SPECIFICATIONS UC-CF Description Electrical specifications 6 1/2" 165 mm 8 1/2" 216 mm 19 1/2" 495 mm The UC-CF control is designed for spas equipped with either a single- or dual-speed water pump, mood light and ozonator. Input 120 V, 60 Hz, 15 A Output Pump Max. 15 FLA, 60 LRA, 120 VAC Water heater Max. 15 A, 120 VAC Light 12 VAC, 1A max. The total of output current cannot exceed the input rating! 3 1/2" 89 mm 2" 51 mm System features Environmental conditions 4 1/2" 114 mm 2" 51 mm The control keypad features indicator lights and digital display. Water temperature can be displayed in F or C. The mood light can be 12 VAC and is also compatible with the color kinetic module. The control allows the user to choose between two light intensities. A built-in timer automatically turns pump off after 20 minutes, unless manually deactivated first. A 1 kw heater maintains the desired water temperature. A dry-fire probe protects the heater if not enough water is circulating. A temperature probe measures water temperature for digital display. Operating temperature 32 to 122 F (0 to 50 C) Storage temperature -4 to 158 F (-20 to 70 C) 2

UC-CF INSTALLATION & INTERCONNECTIONS A Pump receptacle Ozonator receptacle Power input Dry-fire probe Power unit The power unit is self-supported, being directly fixed to the heater. The heater must be attached securely to the spa's plumbing circuit. It must be located under the spa in an easily accessible location, at least 6" (150 mm) above ground level. An access panel must be provided. Important: Power must remain OFF until all connections have been completed. It is mandatory to connect the control to a circuit protected with a Class A Ground Fault Interrupter. Power input Locate the power input cable. If the power input cable is equipped with a 15 A Nema plug, simply insert the plug into an electrical outlet. If the power input cable is not equipped with a plug, connect the individual wires to the electrical circuit through a junction box, ensuring to correctly follow the color codes. Keypad No other electrical equipment may be connected to this circuit. A cable is provided to connect the keypad to the power unit. B Temperature sensor Dry-fire detector Light Pump Locate the pump receptacle on the power unit. Then, connect the pump cable to pump receptacle. Light Attach light socket to the spa and connect light cable to the power unit. Keypad Dry-fire probe Figures A and B above: View of power unit connections from both sides. Dry-fire probe Make sure the dry-fire probe is located on the up-side of the end-piece on the intake side of the heater. Ozonator Locate the ozonator receptacle on the power unit. Connect the ozonator cable to the receptacle. All accessories must be grounded to a second safe earth ground. GECKO Subject to technical modifications without notice 3

KEYPAD INSTALLATION UC-CF A 1" dia 25 mm 2 5/8" 67 mm 1" dia 25 mm Keypad The keypad must be installed directly on the spa (or very close to it) within easy reach of the spa user. Procedure B 1" (25 mm) dia. drill 1- Select the most appropriate location to install the control keypad. 2- Drill two 1" (25 mm) diameter holes as shown in Figure B. Cut out the material between the two holes. Bath edge 3- Connect the keypad as shown in Figure A before securing it to the spa. 4- Insert the keypad into opening you have cut out. Optional holder plate available to fix more securely in place (see Figure C). C Keypad Holder plate Wing nuts 4

UC-CF INSTRUCTIONS Indicators Pump key Press Pump key to turn the pump on at low speed. Press a second time to turn pump to high speed (with a dual-speed pump). Press a third time to turn pump off. When pump is started, it will automatically run for 20 minutes, unless manually deactivated first. The "Pump" indicator lights up on the keypad when pump is on at high speed. It flashes when pump is on at low speed. Display Keys Light key Press Light key to turn the light on at high intensity. Press a second time to change light to low intensity. Press a third time to turn light off. A built-in timer turns the light off 2 hours after the pump has shut down, if the light has not been turned off manually. The "Light" indicator lights up on the keypad when light is on at high intensity. It flashes when light is on at low intensity. Up & Down arrow keys Press and hold Up or Down arrow key to set the current water temperature setting. The selected temperature ("Set Point" value) will be displayed for 5 sec. The "Set Point" indicator light tells the spa user that the temperature shown is the desired, and NOT the current water temperature. Water temperature can be adjusted in one-degree increments from 59 to 104 F (15 to 40 C). Automatic water heater start When the water temperature falls 1 F (0.5 C) lower than Set Point, the heater automatically comes on until the temperature reaches Set Point plus 1 F (0.5 C). The "Heater" indicator lights up on the keypad when heater is on. Note: If your system is configured in Low Current mode, the heater will not start if pump is running at high speed. The "Heater" indicator will flash. 5

INSTRUCTIONS & OTHER FEATURES UC-CF Filter Cycle indicator Filter cycle The system automatically performs two filter cycles per day, at 12-hour intervals. During filter cycle, the pump will be activated for a predetermined number of hours. Keys Display Light key To set filter cycle duration: Press and hold Light key for 5 seconds. The display will show "Fxx", with "xx" representing the current set duration of filter cycle in hours. Press Up or Down arrow key to change setting from 2 to 6 hours. When the setting you want is displayed, press Light key again. The filter cycle will start immediately. This process also sets the start time of the filter cycles, which will start up every 12 hours from the time the initial cycle has been programmed. 40-minute filter cycle time out: If you turn pump or light on during a filter cycle, the cycle will be interrupted and will only resume 40 minutes after you (or the system) have turned the last active output off. The "Filter Cycle" indicator will flash. Water temperature display The 3-digit LED display shows the water temperature reading. The reading is updated every second. Additional features Temperature probe During normal operation, the display will show the current water temperature. Dry-fire probe The system is equipped with a dry-fire probe, which will shut the heater down in the event that there is not enough water in the heater. 6

UC-CF OTHER FEATURES Smart Winter Mode High limit temperature Water level sensor Temperature probe UC-CF packs are equipped with a special sensor that measures the air temperature in the spa's plumbing area. If air cold enough to freeze water in the pipes is detected, the system automatically activates Smart Winter Mode for 24 hours. In this mode, if a pump is not turned on within 2 hours, the system automatically turns it on for one minute to prevent freezing. The High Limit temperature sensor will cause the system to shut down the heater because the water temperature AT THE HEATER has reached 119 F (48 C). 3 flashing dots will appear on the display. Turn breaker off then back on to reset the system. To prevent a "dry fire" in the heater, a water level sensor is installed near the heater pipe. The unit constantly verifies the status of the water level sensor. If no water is detected, heater is shut down. Three flashing dots are then displayed until problem is corrected or if request for heat is cancelled by decreasing temperature set point. If the system detects a problem with the water temperature probe, the wrong temperature will be displayed. Check the connection to the board. When pump is running, "Filter Cycle" indicator will flash. Overtemp mode protection If water temperature IN THE SPA reaches 112 F (44 C), the display will start flashing and all pumps and accessories will be shut down until the water cools down to109 F (43 C). During Overtemp Mode only Smart Winter Mode and keys that don't start accessories will be functional. Note: In the case of either Overtemp or High limit protection, DO NOT ENTER the water. Allow water to cool down to109 F (43 C), then power down to reset the error. 7

Clearly Advanced Spa Systems! For more information about our spa packs and all our other products and services, visit our web site at www.geckoalliance.com Gecko Alliance 450 des Canetons, Quebec City (QC) G2E 5W6 Canada, 1.800.78.GECKO 9225 Stellar Court, Corona, CA 92883 USA 951.667.2000 Rev. 09/07