ViscoClock plus AUTOMATIC VISCOSITY MEASUREMENT EASY AND PRECISE

Similar documents
OPERATING MANUAL. ba75825e03 12/2015 LR 925/01 LR 925/01-P LR 925/01(-P) ULTRAPURE WATER CONDUCTIVITY MEASURING CELL

LAUDA ECO. Precise, economical, flexible

GENYO Series ELECTRIC PUMP CONTROL AND PROTECTION SYSTEM

Flygt MAS 711. Monitoring system for Flygt pumps

Via Umberto Giordano, Padova Tel Fax VERSIONS ACCURACY

ecocirc XL HIGH EFFICIENCY LARGE WET ROTOR PUMP FOR HEATING, COOLING AND POTABLE WATER SYSTEMS A-162C

SHAKING WATER BATHS ENGLISH

Hotplates, Magnetic Stirrers and Stirring Hotplates

LAUDA ECO. Precise, economical, flexible

The right temperature worldwide NEW. LAUDA Integral XT. Professional thermostating for pilot plant and mini-plant purposes. Product information

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

Technical Specifications...46

Thermostats designed

SIMPLEX WEATHERPROOF CONTROL PANELS

Vacuum Controller with Control Unit VC 900

Shop. Item Information. Interface I-100 For V-100/V-7x0. Send item information. Show item in shop. Add item to cart.

SimpleVIS Viscometer Reference Guide P

LAUDA TecInfo Viscometry No 3

Thermostats designed

Frost Protection Thermostat

INSTRUMENTS FOR SPECIAL REQUIREMENTS

COMFORT IP: Room Control Unit Radio with Display

TECHNICAL BROCHURE BCPSDWWP R2 SIMPLEX/DUPLEX WASTEWATER DISCONNECT STYLE PANELS

Constant climate chambers

DP 300 mobile dew point instrument

Digital, not analog: One manifold for all refrigeration systems.

SONOCHEK The ultrasonic testing device

50/60 Hz. ecocirc BASIC Series WET ROTOR CIRCULATORS FOR HEATING, COOLING AND SANITARY SYSTEMS. ErP 2009/125/EC

Thermo Scientific Round Top Hotplate Stirrers. Make safety and accuracy part of your routine

- ibidi heating system - stage top incubator for life cell imaging

ST710-KHJV.03. Wiring diagram. Product description. Temperature controller. Order number

Thermo Scientific Round Top Hotplate Stirrers. Make safety and accuracy part of your routine

Constant climate chamber with humidity

Process Alarm Module RTA 421

M-Sens 2. Online moisture measurement for solids. Operating Instructions. SWR engineering Messtechnik GmbH PART OF THE ENVEA GROUP

User Manual. MS7-H550-Pro MS7-H550-S MS7-Pro MS7-S

GMH 285 / GMH 285-BNC

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Vacuum drying oven for non-flammable solvents

Shop. Item Information. Rotavapor R-300 B-305, SJ24/40, C, P+G, WB, 110V. Send item information. Show item in shop. Add item to cart.

Designed for testing three-phase circuits up to 600V Install on line or load side of electrical disconnect Detects absence of AC and DC voltage

Manufacturer since

Blockpumps. Vogel Series LSB. Lenntech. Tel Fax

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

Product Bulletin. VeriSafe Absence of Voltage Tester. The Safe Way to Verify the Absence of Voltage.

Domestic. Pump Series CB and CBE Condensate Units SINGLE OR DUPLEX 1,000 THRU 140,000 SQ. FT. EDR-250 THRU 34,748 LB./HR.

/8 DIN Level Indicator

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

CERTIFICATE of Product Conformity (QAL1)

Incubating Shaker with Cooling

Compact Ultra Low Temperature Chamber

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

Process Automation. Sensors and Systems: Level Sensors Level Switches Overfill Prevention Pressure Sensors Temperature Sensors

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:

COA-2010-F Electronic CO 2

Miniature Infrared Temperature Sensors with Optional Touch Screen Display. PSC-SSS-PM with touch screen display (-CRT version)

M-Sens 2. Online-Moisture Meter for Solids. Operating Instructions. SWR engineering Messtechnik GmbH

LAUDA Additional devices Immersion coolers, through-flow coolers, circulation heat exchangers

Quadron UV Series. Sustainable UV Disinfection with Minimum Footprint

E-pro. Time adaptor with E-Pro Stick for thermostatic valves

Pasto Sous vide water bath

Room Temperature Sensors

for relative humidity and temperature with calibration certificates

Temperature Solutions Line Card

Mark 25 Ultrapure Water Conductivity Analyzer

Digital 7 Square Plate Magnetic Stirrer

Constant climate chambers

Lowara ecocirc and ecocirc PREMIUM THE NEW HIGHLY EFFICIENT CIRCULATORS WITH THE PATENTED ANTI-BLOCK-TECHNOLOGY

Lowara ecocirc and ecocirc PREMIUM

Huminator II. Precision Humidity Generator. ww.testo.in

Constant climate chamber with ICH-compliant illumination

DEKO 260 Washer - Disinfector - Dryer

HPLC Column Ovens and Temperature Controllers

Advantages / Characteristics

Jetstream Series HPLC - PELTIER COLUMN-THERMOSTATS 1. GENERALITIES

Peltier cooler/heater PCH-1 / PCH-2

NEW Lowara ecocirc PRO The new high efficiency domestic hot water PumPs with automatic air venting function and TheRmaL insulation shell

Product Bulletin. VeriSafe Absence of Voltage Tester. The Safe Way to Verify the Absence of Voltage.

BATHS; WATER AND OIL, SAND, AND ULTRASONIC Summary table of the different models

Pressure measuring instruments

Analyze IT. Process Gas Chromatograph. PGC2000 Series

INSTRUCTION MANUAL. Stirring hotplate (with probe and stand) Brand : (Dragon laboratory)

Figure 1 DirectLine DL423 Sensor. Description, continued

TECHNICAL BROCHURE BCALARM R4. Indoor and Outdoor Panels and Accessories

Product Bulletin. VeriSafe Absence of Voltage Tester. The Safe Way to Verify the Absence of Voltage.

Dräger X-zone 5500 Area Monitoring

Type CSB-L 8s CSB-L 20s

Easy to use, initiate test with the push of a button No additional tools required Provides visual alert to abnormal power conditions

www

Measurement Solutions for Refrigeration Technology.

Flygt Top-Entry Agitators CONVENIENT AND EFFICIENT

Heaters, Thermostats and Hygrostats


FIDAS FINE DUST MONITORING SYSTEMS

MAKING MODERN LIVING POSSIBLE. Installation Guide. ECtemp 550. Electronic Intelligent Thermostat.

SmartShelter Room. Technical Description. Version 1.1 Jul. 2017

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

Incubators. with BioCote antimicrobial protection

Inline Pumps LR/LMR & LRZ/LMZ, LER & LEZ. Lenntech. Tel Fax

Item Number Description Price. Accessories " Diesel/Water/Waste tank sender $ Battery temperature sensor $2.22

Transcription:

ViscoClock plus AUTOMATIC VISCOSITY MEASUREMENT EASY AND PRECISE

ViscoCIock plus - Measurement plus data storage The ViscoCIock plus is an electronic timing unit for glass capillary viscometers used to determine kinematic and relative viscosity. Succeeding the well-proven ViscoCIock, the new instrument features data storage and simpler handling. The ViscoClock plus is especially designed for Ubbelohde type viscometers which are well-known for highest precision. The ViscoCIock plus The ViscoClock plus automatically measures the flow time of temperature-stabilized liquids in capillary viscometers by means of infrared light barriers: the manual measurement with a stopwatch becomes obsolete. The viscometer including a sample is inserted into the ViscoClock plus and immersed into a thermostatic bath for temperature stabilization. After thermostating, the sample is pumped into the measuring bulb, and the flow time is detected automatically. The large display enables easy read-off of flow times and additional information: date, time, sample ID and viscometer ID. ViscoCloc ViscoClock plus - head 2

Automatic measurement of flow times The ViscoCIock plus is designed for SI Analytics Ubbelohde, Micro Ubbelohde and Micro Ostwald viscometers. The flow time is measured automatically by two infrared light barriers which detect the passing liquid meniscus. The repeatability of the automatic time measurement is considerably higher in comparison to the measurement using a stop watch. Therefore some viscometry standards allow a flow time reduction in case of automatic flow time measurement. Properties and materials The ViscoCIock plus can be used for measuring temperatures ranging from -40 C to 150 C. The stand of the ViscoClock plus ist made of high quality polymer PPA. For temperature stabilization in a thermostatic bath, the following liquids are suitable: Water, alcohol, glycol, paraffin oil, and silicon oil. The electronic measuring unit is built-in to a PP casing. Easy handling The ventilation of Ubbelohde viscometers is managed by an electromechanic valve which makes handling easier in comparison to the mechanical mechanism of the previous ViscoClock. Data storage The measuring results of the ViscoClock plus can be stored on a USB flash drive including date, time and sample/viscometer ID. The data are stored as pdf (non-editable) and csv (editable). Alternatively, for data transfer the ViscoClock plus can be connected to a printer (TZ 3863) or a PC. k plus Automatic and precise flow time measurement for a low price Suitable for SI Analytics Ubbelohde, Micro Ubbelohde and Micro Ostwald viscometers Data storage incl. time, date, viscometer and sample ID Stand is made of high performance engineering plastic PPA and enables measuring temperatures up to 150 C Electromagnetic venting valve for convenient handling of Ubbelohde viscometer Compatible with all SI Analytics thermostatic bath types Benefits ViscoClock plus 3

ViscoCIock plus - The plus for your measurements Sample and viscometer identification ViscoClo To allocate the stored measuring results, the user can enter 2-digit numbers to the ViscoClock plus before measurement. These IDs together with date and time ensure an unambiguous assignment of the flow times. Absolute viscosity To determine absolute kinematic viscosities, calibrated viscometers have to be used. To guarantee best accuracy, viscometers which were calibrated by automatic measurement should be used. The constant of automatic calibration can be slightly different in comparison to manual calibration, as the level of the light barriers may not be identical to the position of timing marks. Relative viscosity For determination of relative viscosities, calibrated as well as non-calibrated viscometers can be used. For evaluation, the calibration constant is not required in this case. Well arranged: The new display The viscometer stand: high-performance plastic PPA 4

ViscoCIock plus - Perfectly harmonized...with our thermostats ck plus Our ViscoClock plus is perfectly harmonized with our thermostat baths. If needed we provide you with perfectly matching ViscoClock modules.. Thermostat CT72/P Thermostat CT72/2 5

Technical Data - ViscoCIock plus Measuring range - Time up to 999.99 s; resolution 0.01 s Accuracy of time measurement ± 0.01 s / ± 1 digit; however no more precise than 0.1 %; indicated as measuring uncertainty with a confidence level of 95 % Measuring range - viscosity 0.35 to10,000 mm²/s (cst) the absolute, kinematic viscosity is additionally dependent on the uncertainty of the numerical value of the viscometer constant and on the measuring conditions, in particular the measuring temperature. Display LCD grafic display (FSTN) 128x64 pixel, 51x31mm (w x h) seconds indication with 2 decimal digits after the decimal point, resolution 0.01 s Voltage supply DC + 9 V Power supply socket for low voltage connection: coaxial power connector, inner diameter 2.1 mm, plus pole at inner contact for connection of Universal power supply TZ 1858 Power supply in accordance to class of protection III degree of protection for dust and humidity IP 50 in accordance with DIN 40 050 Universal power supply TZ 1858: 100 240 V, 50 60 Hz (9 V, 550 ma) not suitable for use in areas subject to explosion hazards Plug Connections USB Host to connect USB flash drive or printer (TZ 3863) USB OTG to connect (PC), printer (TZ 3863) or USB flash drive Type A USB connector Type B mini USB connector Ambient Conditions Ambient temperature + 10 to + 40 C for storage and transport Operating temperature stand: 40 to + 150 C electronic measuring unit: +10 to +40 C Humidity in accordance with EN 61 010, Part 1; max. relative humidity 80 % for temperatures up to 31 C, decreasing linearly to 50 % of relative humidity at a temperature of 40 C Housing Materials stand: polyphthalamide (PPA) casing*: polypropylene (PP) gaskets: silicone Dimensions ~515 x 90 x 30 mm (H x W x D) Weight ~450 g (without viscometer) power supply unit: ~220 g Country of origin Federal Republic of Germany CE symbol In accordance with low voltage guideline 2014/35/EU Test regulation EN 61 010-1:2011-07 for laboratory instruments in accordance with EMC regulation 2014/30/EU Test regulation EN 61 326 Part1:2012 In accordance with RoHS regulation 2011/65/EU; Test regulation EN 50 581:2013-02 FCC Symbol Viscometer types Ubbelohde (DIN; ISO; ASTM; Micro), Micro-Ostwald, manufactured by SI Analytics Transparent The ViscoClock plus can be used in all SI Aanyltics bath types thermostatic baths 6 * Use in heat carrier liquids can result in discoloration of the synthetic material. The discoloration does not, however, have any effect on the function and quality of the ViscoClock. Subject to technical changes.

Ordering Information Type No. Order No. Description ViscoClock plus 285417900 Timing unit for capillary viscometer. Including power supply 100-230V and hand pump ViscoClock plus M1, 230V 285417910 ViscoClock plus and acrylic glass thermostatic bath CT72/P (230V) for temperatures +10 C +60 C ViscoClock plus M1, 115V 285417920 ViscoClock plus and acrylic glass thermostatic bath CT72/P (115V) for temperatures +10 C +60 C ViscoClock plus M2, 230V 285417930 ViscoClock plus and glass panelled thermostatic bath CT72/2 (230V) for temperatures -40 C +150 C ViscoClock plus M2, 115V 285417940 ViscoClock plus and glass panelled thermostatic bath CT72/2 (115V) for temperatures -40 C +150 C Get our know-how into your lab! With our Visco Handbook. OUR LONG EXPERIENCE IN THEORY AND PRACTICE IN THE FIELD OF VISCOMETRY HAS BEEN COLLECTED FOR YOU IN OUR NEW VISCO HANDBOOK. HERE YOU WILL FIND EVERYTHING WORTH KNOWING ABOUT. GET YOUR PRINT COPY NOW! FOR FREE. Please send us an Email with your complete contact details and the number of Handbooks you need to: visco.si@xyleminc.com 7

Xylem ˈzīləm 1) The tissue in plants that brings water upward from the roots; 2) a leading global water technology company. We re a global team unified in a common purpose: creating innovative solutions to meet our world s water needs. Developing new technologies that will improve the way water is used, conserved, and re-used in the future is central to our work. We move, treat, analyze, and return water to the environment, and we help people use water efficiently, in their homes, buildings, factories and farms. In more than 150 countries, we have strong, long-standing relationships with customers who know us for our powerful combination of leading product brands and applications expertise, backed by a legacy of innovation. For more information on how Xylem can help you, go to www.xyleminc.com SI Analytics GmbH Hattenbergstr. 10 55122 Mainz Germany Phone: +49.(0)6131.66.5111 Fax: +49.(0)6131.66.5001 E-Mail: si-analytics@xyleminc.com Internet: www.si-analytics.com presented by SI Analytics is a trademark of Xylem Inc. or one of its subsidiaries. 2016 Xylem, Inc. 980 095US Version 05/2016