SYSTEM CONTROL KIT Model: CK-41P

Similar documents
120 VAC SYSTEM CONTROL KIT

120 VAC SYSTEM CONTROL KIT Model: CK-63

24 VAC SYSTEM CONTROL KIT Model: CK-91F and CK-91FG

SYSTEM CONTROL KIT READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

COMBUSTION AIR SYSTEM Model: CAS-3

COMBUSTION AIR SYSTEM

BIG BOOT COMBUSTION AIR KIT Model: CAS-2BB, CAS-2CB, CAS-2B375

24 VAC SYSTEM CONTROL KIT

POWER VENTER SYSTEM MODEL: PVO-300, PVO-600

120 VAC SYSTEM CONTROL KIT

SIDEWALL POWER VENTING KIT

POWER VENTER SYSTEM. Model: PVG-100, PVG-300, PVG-600

24 VAC SYSTEM CONTROL KIT

SYSTEM CONTROL KIT. Model: CK-62. Designed for use on SWG Series Power Vent Hoods for controlling oil fired heating appliances with 120 VAC controls.

24 VAC SYSTEM CONTROL KIT

SIDEWALL POWER VENTER KIT

COMBUSTION AIR SYSTEM

ELECTRONIC FIREPLACE DAMPER

MODEL HS115-3, HS115-4 & HS115-5 WIRING DIAGRAM ADDENDUM

POWER VENTER SYSTEM. Model: PVO-300, PVO-600

ELECTRONIC FIREPLACE DAMPER

e Heater/Exhaust Fan/Light User s Guide

POWER VENTER. Model: PVE Series

e Bath Fan with Light User s Guide

e Bath Fan with Light User s Guide

Installation Manual. THM-0100 Setpoint Thermostat Version THM HBX Control Systems Inc.

e Bath Fan with Light User s Guide

Discontinued Old-Style Switch

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

DBF 4XL Dryer Booster Fans

Sound Cover [ , , , ]

INSTALLATION, OPERATION AND MAINTENANCE

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

Installation Manual. Expansion Module 0100 Version 1.0 EXP HBX Control Systems Inc.

DEDPV-705, DEDPV-705 Hi Alt Dryer Exhaust Duct Power Ventilator (DEDPV)

CVS Model Inline Multi-Port Ventilators

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

INSTALLER S & OWNER S MANUAL

Quest Power Electric Heat EHS 31 Pro

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

The Extraordinaire OWNER S MANUAL. Orbital Ceiling Fan. Model No. OF110** READ AND SAVE THESE INSTRUCTIONS. Net Weight 14.5 lbs. or 6.59 kg.

TJERNLUND PRODUCTS, INC.

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

Phoenix AirMAX - Radial Air Mover

Energy Manager INSTALLATION INSTRUCTIONS. Keep these instructions with the boiler at all times for future reference

MODEL CDB8 INSTALLATION INSTRUCTIONS

MaxLite 4, 6, 8 & 9 LED Architectural & Commercial Downlights

INSTALLER S & OWNER S MANUAL

Viessmann B1HA Boiler Series

Interrupted Ignition Series Oil Primary Control

Owner s Manual Phoenix FireBird

Installation, Operation & Service Manual

INSTALLATION INSTRUCTIONS

Quest PowerHeat HFC 100 Pro

PLL. Pump-Lead-Lag. Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control. Installation and Operation Manual

PLL Pump-Lead-Lag. Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control. Installation and Operation Manual

Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual

Instruction Leaflet. Read instructions before operating. Retain for future reference.

Installation Manual WARNING. Add-on Controller Installation Kit NPE-180A/210A/240A

Air Pump Up to 800 gallons

MaxLite LED Vapor Tight Linear Fixture

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

(HSTAT Series) Instruction Manual

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model 120VC Single Relay (100/25 PPM) (200/35 PPM)

Easy installation in both new construction and retrofit. ZB90C ZB110C X2 Multi-Speed Ventilation Fan INSTALLATION GUIDE

FLCH4R Garage and Utility Electric Heater

2-Port alarmcharge Hub - Manual

DUST FREE CARBON Whole House Air Purifier

ECCOTEMP. Point of Use Tankless Water Heaters EP-2.4 / EP-7.0. Installation and Operating Instruction Manual. Shop Online.

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

be liable for any other loss or damage, whether direct, indirect, incidental or consequential.

Patent Pending invent for New Construction

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

BUNN CWT-CS CWTF-CS BUNN-O-MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS PHONE: (217) FAX: (217)

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

MaxLite LED Round Pendant Highbay Series

DISCONTINUED VERSION The information in this manual is no longer current. OPERATING & SERVICE MANUAL

INFRARED RADIANT HEATERS

Quest Power Electric Heat EHS 62 Pro

GA3650TB Blower Accessory

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

Energedry Elite 52K. Operations Manual. Pest Control Electric Heat System. For Professional use only. EPA EST. No AZ-001

Surge Protective Devices Installation, Operation and Maintenance Manual. LowProfile Series: 080 and 120

FOR EASY, FAST INSTALLATION AND FOR RESULTS

Low Temperature Stainless Steel Panel Series Installation and Commissioning Guide

Instruction Leaflet. Read instructions before operating. Retain for future reference.

Installation Instructions

Energedry Eliminator 52K

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N

ion Genesis Pump Controller

OZONE SYSTEM FOR IN-GROUND POOLS New and Existing

Spa Control System OWNER S MANUAL

Energedry Elite Eliminator Pest Control Electric Heat System

Bathroom Exhaust Fan/Fluorescent Light Combination

REPLACEMENT PARTS LIST WARNING

OWNERS MANUAL. CARBON MONOXIDE DETECTOR MODELS Panel Mount & Remote Detectors (R) Guardian Avionics 1951 E. AIRPORT DRIVE TUCSON, AZ.

Installation Manual. Detector Bases: PAD100-IB, PAD100-RB & PAD100-SB

OCH-SSE series Direct Wired Units Indoor * and Outdoor Comfort Heaters

Transcription:

SYSTEM CONTROL KIT Model: CK-41P READ THE INSTALLATION INSTRUCTIONS CAREFULLY & COMPLETELY BEFORE BEGINNING THE INSTALLATION! Designed for use with the SWG Series Power Venter for controlling Natural Gas or L.P. Gas Appliances equipped with a 24V electric damper. It is designed for modular connection to the appliance controls via the damper cable connection. ITEMS INCLUDED IN KIT 1- Control box with mounted pressure switch, post purge timer and 7" vent damper cable 2- Flexible conduit connector 1-1 4" tubing connectors ITEMS NOT INCLUDED IN KIT 1 4" O.D. aluminum, copper or stainless steel tubing Junction box with connectors and additional circuit wiring, if required WARNING: Installer: If the appliance does not have a blocked vent switch, a GSK-3P Spillage Switch Kit, P/N 46458600, (NOT INCLUDED) must be installed. (See Diagram B) READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION. This device MUST be installed by a qualified agency in accordance with the manufacturer's installation instructions. The definition of a qualified agency is: any individual, firm, corporation or company which either in person or through a representative is engaged in, and is responsible for, the installation and operation of HVAC appliances, who is experienced in such work, familiar with all the precautions required, and has complied with all the requirements of the authority having jurisdiction. Please retain these instructions after installation. Installed By: Phone: Installation Date: www.fieldcontrols.com

MOUNTING CONTROL BOX The control box must be mounted within 6' of the vent damper, and within reach of the appliance's existing damper cable. If the control box must be mounted out of reach of the power venter's attached wiring, an additional installer supplied junction box and wiring (with approved wiring enclosure if necessary) will be required. (See Figures 1 & 2) 1. Install the flexible conduit connector onto the CK-41P control box and secure with fastening nut. If additional wiring is required, install the flexible conduit connector onto the installer supplied junction box. 2. Fasten the flexible conduit from the SWG Venter into the conduit connector. Mount the CK-41P control box onto a non-heated vertical surface of the appliance or nearby wall or floor joist through the four dimpled locations on the base of the box. NOTE: The mounted pressure switch diaphragm must be mounted with a vertical orientation; see label on pressure switch. (See Figure 3) If required, run additional wiring as in figure 2 and connect to CK-41P control box, if required, using the supplied flexible conduit connector and approved connectors and anti-short bushings. Figure 1 Figure 2 page 2

PRESSURE SWITCH SENSING TUBE INSTALLATION 1. Attach the 1 4" tubing connector to the pressure tube on the SWG Venter. (See Figure 3) 2. Connect installer supplied 1 4" O.D. aluminum, copper, or stainless steel tubing to the tubing connector. 3. Route the tubing to the CK-41F junction box and connect the tubing to the pressure switch using supplied plastic nut. When routing the tubing, avoid kinking the tubing by bending the tubing too sharply. Support the tubing at 2' intervals using installer supplied tube clamps. PROVING SWITCH ADJUSTMENTS After proper air flow is established, the pressure switch adjustment is made by turning the pressure switch adjustment screw clockwise (See Figure 4) until burner operation stops. Turn the adjustment screw counterclockwise until burner ignites. Turn the adjustment screw an additional 1 4 to 3 4 turn counterclockwise to ensure adequate switch adjustment. WARNING: Failure to properly adjust the pressure switch as specified above could lead to improper operation of the pressure switch, which will result in a hazardous condition and bodily harm! Figure 3 page 3 Figure 4

WIRING CAUTION: Disconnect electrical power when wiring power venter. Wire the venter motor and controls in accordance with the National Electrical Code, manufacturer s recommendations, and/or applicable local codes. Units must be grounded. Check ground circuit to make certain that the unit has been properly grounded. The wiring should be protected by an overcurrent circuit device rated at 15 amperes. CAUTION must be taken to ensure that the wiring does not come into contact with any heat source. All line voltage and safety control circuits between the venter and the appliance MUST be wired in accordance with the National Electrical Code for class one wiring or equivalent methods. Route the venter motor and control wiring with an appropriate wiring method. Refer to Wiring Diagrams A and B. LOW VOLTAGE WIRING INSTRUCTIONS FOR BOILERS 1. Route the appliance s vent damper cable to the CK-41P. Plug the cable into the receptacle located inside the CK-41P using the supplied plastic knockout grommet (if the cable does not have a conduit connector). (See Diagram A) 2. Connect the CK-41P s pre-wired damper cable to the vent damper. (See Diagram A) Snap the end of the flexible conduit into place on the vent damper conduit bracket. LINE VOLTAGE WIRING INSTRUCTIONS 1. Verify that the circuit to be supplying power to the CK-41P is disconnected. 2. Connect the CK-41P green grounding wire to the circuit s ground wire. Verify that the control box is properly grounded. 3. Connect 120 volts hot power source wire to terminal L1 on CK-41P. 4. Connect 120 volts neutral power source wire and white wire from venter motor to terminal N on the CK-41P. 5. Connect black wire from venter motor to terminal M on the CK-41P. Refer to the SWG Venter installation instructions for setting system air flow. page 4

Diagram A SYSTEM CONTROL CHECK OUT PROCEDURES 1. Adjust the thermostat and/or aquastat to call for heat and observe the power venting system for proper operation sequence. Repeat if necessary. a. Aquastat calls for heat. b. After a short delay, the relay is energized, the venter motor starts, and the vent damper begins opening. c. Pressure switch closes, the vent damper reaches the open position and the burner starts. d. Aquastat is satisfied, the burner stops and the vent damper begins closing. e. This starts the post purge cycle. Purge time 1 to 2 min. 2. While system is operating, disconnect power to the venter motor. This should open the pressure switch contacts and stop burner operation. page 5

TROUBLE SHOOTING HINTS 1. Venter does not activate when thermostat calls for heat. a. Check wiring: 115 VAC from L1 to ground; N connected to a neutral. b. Check for 24V from orange to black wires on base of timer relay. If no other voltage, the appliance is not calling for heat to the CK-41P. If there is 24 volts continuously for at least 45 seconds, there should be 115 volts from N to M. If not, the time relay is defective, or L1 and N are not properly wired. 2. Flue gas odor: a. Check system draft. Adjust power venter s airflow adjustment damper if necessary. b. Check for negative pressure in building. 3. Venter activates but burner does not fire after a minimum of 45 seconds continuous call for heat: a. Check wiring. b. Check pressure switch adjustment. c. Make sure the vent damper is in open position. d. Check for 24 volts from both yellow wires on pressure switch to black wire on base of timer relay. If neither yellow wire has 24 volts, the vent damper is defective, has loose wiring, or is not receiving call for heat on the orange wire. If one yellow wire has 24 volts but the other does not, the pressure switch is not closing. CAUTION: If for any reason the system has shut down during operation, the cause of the system failure should be investigated and corrected before resetting the safety switch and restarting the system. Diagram B INTERNAL WIRING L1 TO 1 ON POST PURGE TIMER M TO 3 ON POST PURGE TIMER (OTHERS PER HARNESS COLORS) page 6

REPAIR AND REPLACEMENT PARTS LIST REPAIR AND REPLACEMENT PARTS LIST DESCRIPTION PART NUMBER Pressure Switch 46273100 Post Purge Timer 46282800 Wire Harness 46457200 page 7

LIMITED WARRANTY Field Controls, LLC ( Company ) warrants that its products shall be free from defects in material and workmanship under normal use for the limited period indicated, from the date of manufacture, subject to the provisions 1-8 below. Eighteen (18) months All Field Controls Products (except for those listed below as 5 years or 90 days). Five (5) years Field Controls Direct Vent Systems (FDVS), Field Oil Vent Kits (FOVP), and ComboVents (CV). Field Controls warrants that the products listed below shall be free from defects in material and workmanship under normal use for the limited period indicated, from the date of purchase by the consumer, subject to the provisions 1-8 below. Ninety (90) days UV lamps/bulbs Provisions: 1. During the limited warranty period, Company, or its authorized service representative, will repair or replace, at Company s option, without charge, a defective Product. Product that is repaired may be repaired with new or refurbished replacement parts. Product that is replaced may be replaced with a new or refurbished product of the same or similar design. Company will return repaired or replacement Product to customer in working condition. Labor charges are not covered as part of the limited warranty. 2. With regard to UV lamps/bulbs, customer shall be required to include a "valid proof of purchase" (sales receipt) identifying the Product purchased (Product model or accurate date code information) and the date the Product(s) was purchased. 3. Product whose warranty/quality stickers, Product serial number plates or electronic serial numbers have been removed, altered or rendered illegible shall not be covered under the limited warranty. 4. Defective Product must be returned to Company, postage prepaid. 5. IN NO EVENT SHALL COMPANY BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, CONSEQUENTIAL, OR SIMILAR DAMAGES (INCLUDING, BUT NOT LIMITED TO, LOST PROFITS OR REVENUE, INABILITY TO USE PRODUCT, OR OTHER ASSOCIATED EQUIPMENT, THE COST OF SUBSTITUTE EQUIPMENT, AND CLAIMS BY THIRD PARTIES) RESULTING FROM THE USE OF PRODUCT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. 6. THIS WARRANTY AND REMEDIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, REMEDIES AND CONDITIONS, WHETHER ORAL, WRITTEN, EXPRESS, STATUTORY OR IMPLIED. TO THE EXTENT PERMITTED BY LAW, COMPANY DISCLAIMS ALL IMPLIED AND STATUTORY WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. 7. Company makes no warranty of any kind in regard to other manufacturer s products distributed by Company. Company will pass on all warranties made by the manufacturer and where possible, will expedite the claim on behalf of the customer, but ultimately, responsibility for disposition of the warranty claim lies with the manufacturer. 8. Product that has been subjected to misuse, accident, shipping or other physical damage, improper installation or application, abnormal operation or handling, neglect, fire, water or other liquid intrusion are not covered by the warranty. Phone: 252.522.3031 Fax: 252.522.0214 www.fieldcontrols.com Field Controls, LLC P/N 46457800 Rev C 08/09