USER'S INFORMATION MANUAL

Similar documents
USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL

Cast Iron Commercial Hot Water Or Steam Boiler

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL

User manual. Logano GC 124 II. Gas boiler

USER'S INFORMATION MANUAL

USER S INFORMATION MANUAL

ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

USER S INFORMATION MANUAL

READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

User s Information Manual

USER'S INFORMATION MANUAL

KG 092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

User s Information Manual

User s Information Manual Models: 45, ,000 Btu/hr

KGA092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

USER S INFORMATION MANUAL (2,4)SG13B

TGA/KGA024, 030, 036, 048, 060, 072, 090 (2, 2 1/2, 3, 4, 5, 6, and 7 1/2 TONS)

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL

User s Information Manual Galaxy GG/GX Series, Sentry S/SX Series and Sentinel SE Series Gas Boilers with Continuous Burning Pilot

Packaged Gas/Electric Units. Owner s Guide to Operating and Maintaining Your Gas/Electric Unit

FOR FORCED HOT WATER MODEL NUMBERS: 15045, 15070, 15096, 15120, 15145, 15175, 15195, 15245, 15295

OIL FIRED WARM AIR FURNACE. Homeowner Instructions

Model BW9 Gas-Fired Direct Vent Condensing Water Boiler

USERS INFORMATION MANUAL FOR GAS FIRED BOILERS

User's Infomation Manual

USER S INFORMATION MANUAL

Operating instructions

OWNER S MANUAL HIGH EFFICIENCY VARIABLE SPEED GAS-FIRED FURNACES

WARNING FIRE OR EXPLOSION HAZARD.

WHAT TO DO IF YOU SMELL GAS

SLP98UH SERIES VARIABLE CAPACITY GAS FURNACE WARNING WARNING

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

P.O. Box , Dallas, TX USER'S INFORMATION MANUAL Single-Stage Warm Air Gas Furnaces

USER'S INFORMATION MANUAL

MANUAL WARNING FIRE OR EXPLOSION HAZARD. SL280UHNV SERIES WHAT TO DO IF YOU SMELL GAS:

USER'S MANUAL PGE Single Package Rooftop

G61MPV SERIES GAS FURNACE WARNING

Operating instructions

USER S INFORMATION MANUAL

WARNING FIRE OR EXPLOSION HAZARD.

GOLD CGt. User s Information Manual. Natural gas-fired water boiler with tankless heater

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

G95V NATURAL AND PROPANE GAS TWO STAGE HIGH EFFICIENCY (CONDENSING) WARM AIR FURNACE USER S INFORMATION MANUAL

RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE :$51,1*

EL195UHE SERIES GAS FURNACE WARNING WARNING

ML180UH SERIES GAS FURNACE WARNING WARNING

Fig. 1 - Unit PGD4, PGS4, WPG4

Elite. User s Information Manual. Elite and Elite VWH* All Models

TO DO IF YOU SMELL GAS

EL195DFE SERIES GAS FURNACE WARNING

15B SERIES II. Models 15B045FE 15B070FE 15B096FE 15B120FE 15B145FE 15B170FE 15B195FE 15B245FE 15B295FE

EL296UHV SERIES GAS FURNACE WARNING WARNING

HWX GAS BOILERS USER S INFORMATION MANUAL

Owner s Information Manual

HOME OWNER S INFORMATION Induced Combustion Gas Furnace

USER S INFORMATION MANUAL Model: HSE 125 N/P, HSE 145 N/P Gas-fired, Condensing Boiler and Instantaneous Water Heater

MC Series Gas-Fired Heating Appliance

EL195UH SERIES GAS FURNACE WARNING

Bosch 80% AFUE Gas Furnace BGS80 Model

USER S INFORMATION MANUAL

15B SERIES II. Models 15B045FE 15B070FE 15B096FE 15B120FE 15B145FE 15B170FE 15B195FE 15B245FE 15B295FE

User s Information Manual Lynx Direct-Vent Sealed Combustion Condensing Boiler Model LX-90, LX-120, LX-150

USER S INFORMATION MANUAL SLP98UHV SERIES

MGB CAST IRON GAS FIRED BOILERS FOR FORCED HOT WATER With Hydrolevel Control. Models MGB-50J MGB-75J MGB-100J MGB-125J MGB-150J MGB-170J MGB-200J

MGB CAST IRON GAS FIRED BOILERS FOR FORCED HOT WATER. Models MGB-50J MGB-75J MGB-100J MGB-125J MGB-150J MGB-170J MGB-200J

INDUCED DRAFT HIGHBOY AND COUNTERFLOW/HORIZONTAL GAS FURNACE

Packaged Gas/Electric

DXL SERIES II CAST IRON GAS FIRED BOILERS FOR FORCED HOT WATER. Models INSTALLATION, OPERATION & MAINTENANCE MANUAL

INSTALLATION AND OPERATION MANUAL GAS SKILLETS MODELS: GTS-30 GTS-40

User s Information Manual

Owner's Manual. Induced Combustion Gas Furnace ! WARNING NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.

BC Series II OIL-FIRED CAST IRON BOILER INSTALLATION, OPERATION & MAINTENANCE MANUAL FOR US AND CANADIAN SALES

Using it in an enclosed space can kill you.

User s Information Manual

Owner's Guide to Operating and Maintaining Your Gas/Electric Unit

PROBLEM CAUSE SOLUTION

GAS BOILERS USER'S INFORMATION MANUAL SG-135-E TO SG-495-E AAA-480 TO AAA-3000

USER'S INFORMATION MANUAL

STARFIRE IV SERIES 4 WATER OIL FIRED CAST IRON BOILER

GOLD. User s Information Manual. Water Boiler Series 4

ODVB SERIES Gas Fired Boilers For Forced Hot Water INSTALLATION, OPERATION & MAINTANANCE MANUAL

User s Information Manual

Columbia Boiler Company

Model RGAC/SGAC Self Contained Cooling/Gas Heat MODELS RGAC & SGAC - R22 USER'S INFORMATION, MAINTENANCE AND SERVICE MANUAL

SIERRA RADIANT HEAT MAJESTIC OAK VENTED GAS LOG KIT INSTALLATION AND OPERATING INSTRUCTIONS

15B SERIES Cast Iron Gas Fired Boilers For Forced Hot Water

Conversion Instructions Logano G234X. Gas boiler. Please read carefully before installing and servicing. Gas boiler

15B SERIES Cast Iron Gas Fired Boilers For Forced Hot Water

User s Information Manual

DXL SERIES II CAST IRON GAS FIRED BOILERS FOR FORCED HOT WATER

User s Information Manual

MGB CAST IRON GAS FIRED BOILERS FOR FORCED HOT WATER with Honeywell Control INSTALLATION, OPERATION & MAINTENANCE MANUAL

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

LGA/LGC036, 042, 048, 060, 072 (3, 3-1/2, 4, 5, and 6 TONS) LGA/LGC090, 102, 120, 150, (7-1/2, 8-1/2, 10, and 12-1/2 TONS)

DXL SERIES II. Models CAST IRON GAS FIRED BOILERS FOR FORCED HOT WATER INSTALLATION, OPERATION & MAINTENANCE MANUAL

Transcription:

USER'S INFORMATION MANUAL SERIES ODVB GAS FIRED HOT WATER HEATING BOILER WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. If you cannot reach your gas supplier, call the fire department. Installation and service must be performed by a qualified installer, service agency or the gas supplier. Do not use this boiler if any part has been under water. Immediately call a qualified service technician to inspect the boiler and to replace any part of the control system and any gas control which has been under water. Should overheating occur or the gas supply fail to shut off, do not turn off or disconnect the electrical supply to the pump. Instead, shut off the gas supply at a location external to the appliance. ECR International 2210 Dwyer Avenue, Utica NY 13504-4729 Phone: (315) 797-1310 Fax: (866) 432-7329 e-mail: info@ecrinternational.com web site: www.ecrinternational.com P/N 37616001, Rev. B [3/2011]

USERS INFORMATION MANUAL INSTRUCTIONS FOR OPERATION AND MAINTENANCE OF GAS FIRED HOT WATER HEATING BOILER RETAIN FOR FUTURE REFERENCE SAFETY SYMBOLS & WARNINGS The following defined symbols are used throughout this manual to notify the reader of potential hazards of varying risk levels. DANGER Olsen Boilers recommends all boiler maintenance be performed by a trained heating technician. Before any procedures are attempted on this appliance, it is necessary to determine if the ignition system is a electric or standing pilot system. If you are uncertain, contact the manufacturer before proceeding. DANGER Indicates a hazardous situation which, if not avoided, WILL result in death or serious injury. CAUTION Indicates a hazardous situation which, if not avoided, may result in minor or moderate injury. WARNING Indicates a hazardous situation which, if not avoided, could result in death or serious injury. NOTICE Indicates information which should be followed to ensure proper installation and operation. 2

LIGHTING INSTRUCTIONS WARNING Before lighting any type of pilot burner (standing or intermittent), make certain the hot water boiler and system are full of water to minimum pressure of 12 lbs. per square inch in the system, and also make certain that the system is vented of air. Refer to the following appropriate lighting instruction. LIGHTING PROCEDURE FOR BOILER WITH INTERMITTENT PILOT SYSTEM A. B. WARNING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the appliance by hand. Before operating, smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. Read "What To Do If You Smell Gas" on front page of this manual. 4. This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand. 5. Remove jacket front panel. 6. Turn gas control knob clockwise to OFF. See Figure 1. 7. Wait (5) minutes to clear out any gas. If you then smell gas, STOP Follow What To Do If You Smell Gas on front cover of this manual. If you don t smell gas, go on to the next step. 8. Turn gas control knob counterclockwise to ON. 9. Replace jacket front panel. 10. Turn on all electric power to the appliance. 11. Set thermostat to desired setting. 12. If the appliance will not operate, follow the instructions To Turn Off Gas To Appliance on page 5 and call a qualified service technician or your gas supplier. Figure 1 - Intermittent Pilot C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don t try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. E. F. Operating Instructions For Intermittent Pilot System 1. STOP Read the safety information above. 2. Set the thermostat to lowest setting. 3. Turn off all electric power to the appliance. 3

LIGHTING INSTRUCTIONS To Turn Off Gas To Appliance 1. Set the thermostat to lowest setting. 2. Turn off all electric power to the appliance if service is to be performed. Note Some gas control knobs cannot be turned from "PILOT" to "OFF" unless knob is pushed in slightly. DO NOT FORCE. 4. Replace access panel. 3. Push in gas control knob slightly and turn clockwise to "OFF." DO NOT FORCE. Before seasonal start-up, have a qualified service agency check the boiler for soot and scale in the flues, clean the burners and check the gas input rate to maintain high operating efficiency. CAUTION Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after service. The service agency or owner should make certain the system is filled with water to minimum pressure and open air vents, if used, to expel any air that may have accumulated in the system. Check the entire piping system and, if any leaks appear, have them repaired. General Instructions Put about one half teaspoon of SAE 20 or 30 nondetergent motor oil in each opening twice a year. Do Not Over Oil CAUTION Many circulators have an oil opening for the shaft bearing. This should be oiled at the same time for quiet operation. Follow the manufacturer's instructions for oiling the shaft bearing. The venting system should be inspected at the start of each heating season. Check the vent pipe from the boiler to the chimney for signs of deterioration by rust or sagging joints. Repair if necessary. Remove the vent pipe at the base of the chimney or flue and using a mirror, check vent for obstruction and make certain the vent is in good working order. A1795 Figure 2 - Circulator Figure 3 - Boiler Flue Gas Passageways FLUE COLLECTOR HOLD DOWN BOLT VENTER ASSEMBLY BURNERS Many circulators like the one pictured in Figure 2 (above) require periodic servicing. The motor usually has openings at each end to lubricate the bearings. ORIFICES GAS VALVE 4

General Instructions Before seasonal start up it is advisable to have a certified service agency check the boiler for soot and scale in the flues, clean the burners and check the gas input rate to maintain high operating efficiency. The service agency should make certain the system is filled with water to minimum pressure and open air vents - if used - to expel any air that may have accumulated in the system. The entire piping system should also be checked and if any leaks appear, they should be repaired immediately. The venting system should also be inspected at the start of each heating season. The vent pipe from the boiler should be checked for signs of deterioration or sagging joints. Repair if necessary. The following procedure should be followed to clean and check the flue gas passageways: 1. Remove the burners from the combustion chamber by raising the burners 1. up from the manifold orifices and pulling toward the front of the boiler, (See Figure 4) 2. Disconnect the vent pipe from the vent adapter. 3. Remove the jacket front panel. (See Figure 5) 4. Check venter assembly suction pressure. Connect a slope manometer between the venter and the pressure switch with a tee and additional tubing and connectors. Turn the boiler on and read suction pressure on the manometer. Reading should be negative (-).55 ±.05 inches of water column or higher for the DV50 thru 150 and negative (-).65 ±.05 inches of water column or higher for the DV200. If this reading is not attainable, contact a certified service agency. 5. Remove the flue collector and venter assembly from the boiler castings by loosening the hold-down bolts located on each side of the flue collector. (See Figure 3) 6. Visually inspect the venter assembly for any unusual wear or dirt build up. 7. If venter has oil cups lubricate venter motor once a month during the heating season with a few drops of nondetergent motor oil (SAE 20 or 30). Do not over oil. 8. Place a sheet of heavy paper or similar material in the bottom of the combus8. tion chamber and brush down the flue passageways. The soot and scale will collect on the paper and is easily removed with the paper. A visual check of the main burner and pilot flames should be made at the start of the heating season and again in mid-season. The main burner flame should have a well defined inner blue mantel with a lighter blue outer mantel. (See Figure 6) If the flame does not appear this way, check the burner throats and burner orifices for lint or dust obstructions. The pilot flame should envelop 3/8 to 1/2 inch of the tip of the ignition electrode. To adjust the pilot flame, remove the pilot adjustment cover screw on the gas valve and turn the inner screw clockwise to decrease or counterclockwise to increase the pilot flame. See Figure 1. Be sure to replace the cover screw after adjustment to prevent possible gas leakage. The burners and pilot should be checked for signs of corrosion, rust or scale build-up, and cleaned with a nylon bristle brush. The area around the boiler must be kept clear and free of combustible materials, gasoline and other flammable vapors and liquids. The free flow of combustion and ventilating air to the boiler and boiler room must not be restricted or blocked. In the event the flow of combustion products through the flueways or the boiler venting system becomes blocked, a flame roll-out safety switch will shut off the main burner gas. See Figure 5. If this condition occurs, do not attempt to place the boiler in operation. Contact a qualified service agency. It is suggested that a certified service agency be employed to make an annual inspection of the boiler and heating system. They are experienced in making the inspection outlined above and in the event repairs or corrections are necessary, they can make the proper changes for safe operation of the boiler. 5

General Instructions Figure 4 - Burners, Burner Orifices Figure 5 - Boiler Front with Safety Switch VENT PIPE ADAPTER BURNERS JACKET FRONT PANEL GAS VALVE COMBUSTION CHAMBER BURNER DOOR (REMOVED) ORIFICES BURNERS GAS VALVE BURNER ROLL-OUT SAFETY SWITCH Figure 6 - Burner Flame Figure 7 - Burners Pilot Flame 3/8 TO 1/2 IN FLAME IGNITION ELECTRODE 6

NOTES 7

NOTES ECR International 2210 Dwyer Avenue, Utica NY 13504-4729 Phone: (315) 797-1310 Fax: (866) 432-7329 e-mail: info@ecrinternational.com web site: www.ecrinternational.com Date of Installation: Boiler Model #: Installed By: 8